Patients with hypertrophic cardiomyopathy (HCM) have an increased prevalence of atrial fibrillation (AF) compared to the general population, and left atrium (LA) remodeling is strongly correlated with the risk of AF. This prospective, monocentric study aimed to assess the role of LA electrocardiographic and echocardiographic (structural and functional) parameters in predicting the risk for incident AF in patients with HCM.
The study population consisted of 126 HCM patients in sinus rhythm (52.6 ± 16.2 years, 54 men), 118 of them without documented AF. During a median follow-up of 56 (7–124) months, 39 (30.9%) developed a new episode of AF. Multivariable analysis showed that LA booster pump function (assessed by ASr, HR = 4.24, CI = 1.84–9.75, and
Left atrium booster pump function (ASr) and electrical dispersion (Pd) are related to the risk of incident AF in HCM patients. These parameters can provide further stratification of the risk for AF in this setting, including in patients considered at lower risk for AF based on the conventional assessment of LA size.