AUTHOR=Afzal Shazia , Haschemi Jafer , Bönner Florian , Kelm Malte , Horn Patrick TITLE=Case report: Transcatheter edge-to-edge repair after prior surgical tricuspid annuloplasty JOURNAL=Frontiers in Cardiovascular Medicine VOLUME=9 YEAR=2022 URL=https://www.frontiersin.org/journals/cardiovascular-medicine/articles/10.3389/fcvm.2022.1044410 DOI=10.3389/fcvm.2022.1044410 ISSN=2297-055X ABSTRACT=

Residual and recurrent tricuspid regurgitation may occur frequently after surgical tricuspid valve repair. However, reoperation for tricuspid regurgitation is rare, although many patients are again highly symptomatic. Tricuspid transcatheter edge-to-edge repair (TEER) is a promising therapy for severe tricuspid regurgitation. Herein, we report a 77-year-old woman with recurrent symptomatic massive tricuspid regurgitation 2 years after sutured annuloplasty of the tricuspid valve. TEER was successfully performed using the TriClip® device and tricuspid regurgitation was reduced to a mild degree. In conclusion, tricuspid TEER is feasible following surgical suture annuloplasty. TEER is an alternative option for patients with a failed previous annuloplasty repair for tricuspid regurgitation to undergo a less invasive treatment rather than a potentially higher-risk reoperation.