AUTHOR=Bikou Olympia , Tharakan Serena , Yamada Kelly P. , Kariya Taro , Gordon Alexandra , Miyashita Satoshi , Watanabe Shin , Sassi Yassine , Fish Kenneth , Ishikawa Kiyotake TITLE=A Novel Large Animal Model of Thrombogenic Coronary Microembolization JOURNAL=Frontiers in Cardiovascular Medicine VOLUME=6 YEAR=2019 URL=https://www.frontiersin.org/journals/cardiovascular-medicine/articles/10.3389/fcvm.2019.00157 DOI=10.3389/fcvm.2019.00157 ISSN=2297-055X ABSTRACT=
Coronary microembolization is one of the main causes of the “no-reflow” phenomenon, which commonly occurs after reperfusion of an occluded coronary artery. Given its high incidence and the fact that it has been proven to be an independent predictor of cardiac morbidity and mortality, there is an imperative need to study its underlying mechanisms and pathophysiology. Large animal models are essential to perform translational studies. Currently there is no animal model that recapitulates a clinical scenario of thrombogenic microembolism with preceding myocardial ischemia. Therefore, the goal of this study was to develop and characterize a novel pig model of coronary microembolization using autologous thrombus injection (CMET). Twenty-three pigs underwent myocardial infarction through percutaneous balloon occlusion of the left anterior descending artery (LAD). Each animal was enrolled in one of two groups: (1) the CMET group, in which the LAD occlusion was followed by delivery of autologous clotted blood in the LAD (distal to the balloon occlusion) and reperfusion; (2) the ischemic reperfusion (I/R) group, in which the LAD ischemia was followed by reperfusion. Surviving animals underwent functional and morphological characterization at 1-week post-procedure. Three sham operated animals were used as a control. CMET resulted in impaired left ventricular function compared to I/R pigs at 1 week. Three-dimensional echocardiography demonstrated reduced ejection fraction in the CMET group (CMET vs. I/R: 35.6 ± 4.2% vs. 47.6 ± 2.4%,