Skip to main content

ORIGINAL RESEARCH article

Front. Bioeng. Biotechnol., 08 April 2022
Sec. Biosensors and Biomolecular Electronics
This article is part of the Research Topic Micro/Nano Optical Devices for Biosensing and Cellular Analysis View all 9 articles

Comparison of Hydrogen Peroxide Secretion From Living Cells Cultured in Different Formats Using Hydrogel-Based LSPR Substrates

Yang-Jyun Siao,Yang-Jyun Siao1,2Chien-Chung PengChien-Chung Peng2Yi-Chung Tung,
Yi-Chung Tung1,2*Yih-Fan Chen
Yih-Fan Chen2*
  • 1Institute of Biophotonics, National Yang Ming Chiao Tung University, Taipei, Taiwan
  • 2Research Center for Applied Sciences, Academia Sinica, Taipei, Taiwan

Reactive oxygen species (ROS), a number of reactive molecules and free radicals derived from molecular oxygen, are generated as by-products during mitochondrial electron transport within cells. Physiologically, cells are capable of metabolizing the ROS exploiting specific mechanisms. However, if excessive ROS accumulate inside the cells, it will cause the cells apoptosis or necrosis. Hydrogen peroxide (H2O2) is one of the essential ROS often participating in chemical reactions in organisms and regulating homeostasis in the body. Therefore, rapid and sensitive detection of H2O2 is a significant task in cell biology research. Furthermore, it has been found that cells cultured in different formats can result in different cellular responses and biological activities. In order to investigate the H2O2 secretion from the cells cultured in different formats, a hydrogel-based substrate is exploited to separate relatively large molecular (e.g., proteins) for direct measurement of H2O2 secreted from living cells in complete cell culture medium containing serum. The substrate takes advantage of the localized surface plasmon resonance (LSPR) method based on enzyme immunoprecipitation. In addition, the H2O2 secreted from the cells cultured in different dimensions (suspension of single cells and three-dimensional cell spheroids) treated with identical drugs is measured and compared. The spheroid samples can be prepared with ample amount using a designed microfluidic device with precise control of size. The results show that the H2O2 secretion from the cells are great affected by their culture formats.

Introduction

Reactive oxygen species (ROS) are molecules with highly reactive free oxygen radicals, and their important effects on biological activities have been investigated and identified (Gough and Cotter, 2011; Milkovic et al., 2019). Among various ROS, hydrogen peroxide (H2O2), a stable non-radical oxidant, has been intensively studied. H2O2 has been found to increase oxidative stress and damage cells for its excessive production during cell metabolism of aerobic organisms (Gough and Cotter, 2011). Recently, it is discovered that H2O2 can also act as a beneficial signaling molecules in certain cells (Nindl et al., 2004). As a result, it is essential to monitor H2O2 secreted from the cells in a time-lapse manner for better investigation the roles of H2O2 in cellular activities under various stimulations.

In vitro cell culture models have been broadly exploited to investigate underlying mechanisms of the H2O2 secretion due to their well-controlled culture conditions and microenvironments (Hirsch et al., 2014; Queiroz et al., 2021). Recent studies have shown that the cell culture formats can greatly affect the cellular responses under various stimulations. For example, drug treatments on cancer cells cultured in monolayer and three-dimensional (3D) spheroid formats have distinct efficacy and cause different cellular responses (Tung et al., 2011; Patra et al., 2016). In addition, cells cultured in different formats also show different cytokine secretion patterns in temporal domain (Sarkar et al., 2020). Therefore, it is desired to compare the H2O2 secretion profiles between different culture formats to better investigate the underlying molecular mechanisms related to ROS in a more physiological-like microenvironment.

In order to compare temporal H2O2 secretion patterns from the cells in different formats, we develop an integrated approach taking advantage of microfluidic cell culture devices, hydrogel-based substrates and LSPR detection in this paper. Microfluidic devices have been broadly exploited for various cell culture applications due to their advantageous properties including: laminar flow, small sample and reagent volume requirement, and great spatiotemporal controllability (Chen et al., 2011; Peng et al., 2013; Polidoro et al., 2021; Zamprogno et al., 2021). Recently, three-dimensional spheroid culture has obtained increasing attention due to its capability of reconstituting three-dimensional physiological microenvironments in vitro (Torisawa et al., 2007; Hsiao et al., 2009; Patra et al., 2013; Patra et al., 2014; Patra et al., 2016; Mulas et al., 2020). Consequently, various microfluidic spheroid cultured devices have been constructed for cell studies. In this paper, our previously developed microfluidic device capable of reliably forming and culturing a number of spheroids with uniform sizes is utilized for the spheroid sample preparation (Patra et al., 2013; Patra et al., 2014; Patra et al., 2016). The spheroids can then be harvested from the devices for the treatments and H2O2 analysis.

For consistent time-lapse H2O2 measurement on the cell culture medium, a hydrogel substrate with LSPR-based detection scheme is constructed based on our previous research (Chen et al., 2021). Comparing to other commonly used detection schemes such as electrochemical measurement (Liu et al., 2017; Sun et al., 2017; Xin et al., 2017; Zhang et al., 2017; Zhao et al., 2019), field effect transistor (FET) (Xie et al., 2016), and imaging of fluorescent dyes (Feng et al., 2017; Velusamy et al., 2019), the LSPR-based detection can be performed with great consistency in a time-effective manner using a simple optical detection setup. In addition, the hydrogel-based substrate can help to alleviate the interference from other soluble factors contained in the complete cell culture medium to improve the detection sensitivity. Furthermore, incorporating the hydrogel with the enzymatic activity of horseradish peroxidase (HRP), we have demonstrated that the substrate can detect H2O2 with great specificity. As a result, the temporal profiled of H2O2 secreted from the cells cultured in different formats can be characterized in a straightforward manner without tedious medium filtration or purification processes (Chen et al., 2021).

In the experiments, human hepatocellular carcinoma cell line is cultured, and H2O2 secretin of the cells in two formats: single cell and three-dimensional (3D) spheroid are characterized. It has been identified that H2O2 can induce hepatocyte apoptosis by mechanisms different from other superoxide anions (Conde de la Rosa et al., 2006; Ma et al., 2015). In contrast, it also suggested that moderate transient increase in H2O2 production can mediate stress adaption and improve cell survival (Miller et al., 2019). Therefore, it is desired to investigate the transient response of the hepatocytes in H2O2 production under stimulation. For (Miller et al., 2019) comparison, the cells are stimulated using ascorbic acid to promote their H2O2 secretion, and the time-lapse H2O2 concentrations in complete culture medium within 6 min after the stimulation are measured every 30 s. The results show that the H2O2 in complete medium with single cells and cell spheroids cultured in it can be successfully detected, and the culture formats affect the temporal variation of H2O2 concentrations. The integrated approach provides a straightforward platform to understand the dynamic secretion patterns of H2O2 from the cells cultured in different formats, and further explore the roles of H2O2 in carious physiological and pathological microenvironments.

Materials and Methods

Hydrogel Substrate Preparation and Optical Setup for H2O2 Detection

In order to perform time-lapse detection of H2O2 secreted from living cells cultured in different formats, a hydrogel-based substrate capable of generating optical spectrum shift while reacting with H2O2 due to LSPR and enzyme immunoprecipitation is exploited in the experiments as shown in Figure 1A. The substrate is prepared by mixing gold nano-rods (AuNRs) (NR-40-650, NanoSeedz, Hong Kong), 3-amino-9-ethylcarbazole (AEC) (Sigma-Aldrich), HRP (Sigma-Aldrich), and agarose (Sigma-Aldrich) with final concentrations of 8.48 × 1010/ml, 0.125% (v/v), 1.25 μg/ml, and 1.5% (w/v), respectively. In the substrate, the HRP-catalyzed chromogenic reaction forms red precipitates near the AuNRs embedded in the substrate when reacting with H2O2. The reaction is exploited to generate the spectral shift as shown in Figure 1B. The porous agarose hydrogel mixed in the substrate can stabilize the nanorods and further minimize interferences from other molecules in complex environments like complete cell culture medium. The hydrogel substrate has been tested using the H2O2 of different concentrations in pure water, DPBS, and complete medium with 10% FBS in our previous research. The results show that the measured LSPR wavelength shifts obtained from the three solutions are identical confirming the hydrogel substrate is capable of alleviating the interference from soluble factors (Chen et al., 2021), and also suggest that the LSPR wavelength shift is insensitive to the refractive index variation caused by the composition and biomolecules in the medium. The entire substrate is fabricated on a microscope slide, and the mixed hydrogel is placed on the slide and confined by layers of ring-shaped self-adhesive reinforcement labels (thickness: ∼290 μm) as shown in Figure 1C. The detail fabrication process of the substrate is described in our previously published paper (Chen et al., 2021).

FIGURE 1
www.frontiersin.org

FIGURE 1. (A) Schematic flowchart of the experimental procedures to compare the amount of H2O2 secreted from the living cells cultured in different formats using the plasmonic gel films with optical spectrum measurement. (B) Principle of the H2O2 detection using the gel film mixed with agarose gel, gold nanorods, AEC and HRP. (C) Illustration and photos of the experimental optical spectrum measurement setup for the H2O2 detection.

When H2O2 in the sample solution reacts with AEC and HRP, the enzymatic reaction produces red water-insoluble precipitates resulting in a shift in the LSPR wave-length of the AuNRs. As a result, comparing the extinction spectra before and after adding a sample solution, the H2O2 concentration can be quantified by the wavelength shift. In the experiments, an optical fiber-based system is constructed for the spectrum measurement as shown in Figure 1C. In the setup, a broadband tungsten light source (SL1, Stellarnet Inc.) is guided through an optical fiber to illuminate the substrate, and the transmitted light is collected by another optical fiber and guided to a spectral meter (HRS-BD1-025, Mightex, Toronto, ON, Canada) for the spectrum detection. The quantitative data of the detected spectrum is then transmitted to a personal computer to analyze the LSPR wavelength shift using a LabVIEW program. The AuNR used in the experiments has the longitudinal LSPR peak at approximately 650 nm. Therefore, the wavelength shift around 650 nm is used to calculate the wavelength shift. The substrate has been tested to possess great specificity even with addition of other soluble factors [glucose (GLU), glutathione (GSH), dopamine (DA), and uric acid (UA)] and ROS [TBHP, hypochlorite (OCl), superoxide (O2), NO, •OH] in complete cell culture medium (Chen et al., 2021).

Cell Culture

In order to compare the H2O2 secretion from the single cells and cells in 3D spheroid formats, human hepatocellular carcinoma cells (HepG2, 60025, Bioresource Collection and Research Center, Hsinchu, Taiwan) are exploited in the experiments. The stocks of the cells are cultured using MEM (Gibco 41090-036, Invitrogen Co., Carlsbad, CA)-based culture medium with 10% v/v fetal bovine serum (FBS) (Gibco 10082, Invitrogen Co.), 1% v/v Antibiotic-Antimycotic (Gibco 15240, Invitrogen Co.), 1% v/v sodium pyruvate (Gibco 11360, Invitrogen Co.), and 1% v/v non-essential amino acids (Gibco 11140, Invitrogen Co.) in a humidified cell incubator maintained at 37°C with 5% CO2. The cells are passaged every 3 days during the experiments.

The single cells and the cell spheroids used in the experiments are first prepared by culturing cells in conventional monolayer and 3D spheroid formats as shown in Figure 1A. For the monolayer cell culture, cells are cultured in T25 or T75 flasks. The single cells are prepared by dissociating the cells using 0.25% trypsin-EDTA (Gibco 25200, Invitrogen Co.), and the dissociated cells are centrifuged at 1,000 rpm for 5 min. The cells are then resuspended into 1 ml culture medium, and 20 μl of the cell suspension is pipetted into a hemocytometer to evaluate the cell density. The remaining cell suspension containing single cells is adjusted to the density of 1.6 × 107 cells/ml for the H2O2 measurement experiments.

For the 3D cell spheroid experiments, the HepG2 spheroids are formed and cultured in a microfluidic device previously designed in our labs as shown in Figure 2A (Patra et al., 2013). In brief, the device is made of an elastomeric material, polydimethylsiloxane (PDMS), due to its optical transparency, gas permeability, and cell compatibility (Xia and Whitesides, 1998; Whitesides et al., 2001). The device is designed with two PDMS layers: a bottom layer with 4,000 cell culture chambers (length × width × depth: 200 μm × 200 μm × 500 μm), and a top layer with a serpentine channel (depth: 200 μm) covering the cell culture chambers. The two layers are bonded using oxygen plasma surface treatment, and the channel walls are coated with 1% w/v Synperonic F-108 (07579, Fluka, Sigma- Aldrich, Co., St Louis, MO) to make them resistant to cell adhesion. To form the spheroids, 200 μl cell suspension with total 8 × 106 cells is introduced into the device, and the growth medium is exchanged every 12 h to maintain the optimized culture condition (Patra et al., 2013). After three day-culture within the device as shown in Figure 2B, the spheroids are harvested from the device by introducing the 20 ml medium with a high flow rate (>1 ml/min). For cell number evaluation, the sample is concentrated to 1.5 ml by centrifugation (700 rpm for 5 min), and the 60 μl well mixed cell suspension with the harvested spheroids is then collected. The cell suspension is diluted using Dulbecco’s phosphate-buffered saline (DPBS) (Gibco 14190, Thermo Fisher Scientific Inc.) to a final volume of 1.5 ml. The saline of the suspension is replaced by cell aggregate dissociation medium (Accumax, 00-4666-56, Thermo Fisher Scientific Inc.) and incubated at 37°C for 15 min to dissociate the spheroids in single cells for cell density evaluation using the hemocytometer. The remaining cell suspension is adjusted to the same cell density used in the single cell experiments (1.6 × 107 cells/ml) by centrifugation (700 rpm for 5 min) and resuspension in the medium for the H2O2 measurement experiments.

FIGURE 2
www.frontiersin.org

FIGURE 2. (A) Fabrication process, schematic illustration, and experimental photo of the microfluidic device for the 3D cell spheroid formation, culture, and harvesting. (B) Experimental photos of the HepG2 cell spheroids formed and cultured within the device for 24, 48, and 72 h, respectively.

Cell Treatment and H2O2 Detection

To observe the difference of H2O2 secretion from the single cells and cell spheroids, ascorbic acid (AA) (A17759, Alfa Aesar) is used to treat the cells (Chen et al., 2021). In the experiments, 3 μm AA with the same volume of the cell suspension is added into the suspension to yield the final AA concentration of 1.5 μm in the suspension solution for the cell treatment. In order to monitor the secretion of H2O2 after the treatment in a time-lapse manner, 60 μl of the cell suspension is collected and pipetted onto the hydrogel substrate right after (t = 0 s) and every 30 s for 4 min after the AA addition. The sample is reacted with the substrate for 30 min before the measurement. Each measurement is performed at five different locations on the hydrogel substrate to alleviate the variation resulted from the uneven distribution of the sample or the substrate compositions.

Fluorescence Staining of the Cells

The viabilities of cells cultured in the flasks, before and after the treatment in different cell formats are checked using a live/dead stain solution containing calcein AM (1 μm) and ethidium homodimer-1 (2 μm) from LIVE/DEAD Viability/Cytotoxicity Kit (L3224, Invitrogen) to ensure the cell compatibility of the experiments and investigate the possible effects from the cell viability on the H2O2 secretion.

Results

Cell Culture and Viability

In order to ensure that the cells can maintain their live status during the entire experiments, the cell viability assays are performed and the results are shown in Figure 3. The brightfield and fluorescence images of the cells cultured in the flask show that the cells can well attach on the flask surface and most of the cells show green fluorescence from the live cell stain, calcein Am. The cell viability is estimated to be higher than 96% for all the experiments confirming the optimized culture conditions of the culture protocol.

FIGURE 3
www.frontiersin.org

FIGURE 3. Brightfield and fluorescence microscopy images of the cells cultured in a flask and a microfluidic device before and after the AA treatment. The cells are stained with cell viability kit. The live cells are stained with calcein AM (green), while the dead cells are stained with ethidium homodimer-1 (EthD-1) (red).

For the single cell experiments, the cultured cells are dissociated into single cells and stained using the cell viability kit before and after the ascorbic acid treatments to observe the effects of the treatments. The fluorescence images (Figure 3) show that most of the cells are alive before and after the treatment. The quantitative average cell viabilities are estimated to be 95.1% and 93.2% with statistical difference (Student’s t-test, p < 0.001, n = 3) before and after the treatment, respectively. The lower cell viability suggests that the additional of ascorbic acid slightly differ the optimized cell culture conditions, which needs to be carefully examined for the following experiments. For comparison, the cells are also stained using the cell viability kit while they are in the spheroid format for the 3D cell spheroid experiments. The brightfield and fluorescence images show the great integrity of the spheroids, and most of the cells show green fluorescence (calcein-AM) indicating their live status before and after the treatments. The average cell viabilities are estimated to be 92.1% and 91.0% without statistical difference (Student’s t-test, p > 0.05, n = 3), respectively. The results suggest that the ascorbic acid treatment has minimal effects on the viability of the cells cultured in the spheroid format, which is different from the observation in the single cell experiments.

H2O2 Measurement

We measure H2O2 of various concentrations in MEM medium supplemented with 10%FBS to obtain a calibration curve for H2O2 detection. Figure 4A shows that the extinction spectra of the plasmonic gel film red-shifted after incubation with 100 μm H2O2. The LSPR shift of the gel film is different for different concentrations of H2O2 as shown in Figure 4B. The calibration curve shows that the LSPR shift increases with the concentration of H2O2 in the range of 0.5–100 μm.

FIGURE 4
www.frontiersin.org

FIGURE 4. Calibration curve for H2O2 detection. (A) Extinction spectra of the plasmonic gel film be-fore and after incubation with 100 μm H2O2. (B) A calibration curve for H2O2 detection. A plot of LSPR shift versus H2O2 concentration. Error bars show standard deviations with n = 5.

Finally, to investigate the difference in the responses to the AA stimulation between HepG2 single cells and 3D spheroids, we use 1.5 μm AA to stimulate both of them and then use the plasmonic gel film to perform time-lapse detection of H2O2 in the complete culture media. The same detection is performed for the cells cultured in both culture conditions without AA stimulation for comparison. In addition, cell-free complete culture media with and without 1.5 μm AA are measured as the control groups. For the time-lapse monitoring of H2O2 secretion, we take a sample of the cell culture medium every 30 s after the AA stimulation and then perform measurement with the plasmonic gel film. Culture media of the control groups and the cells that are not stimulated by AA are sampled and measured at the same time during the time-lapse measurement for comparison. The results, as shown in Figures 5A,B, show that the concentrations of H2O2 in the culture medium of both the single cells and the 3D spheroids increase with time after the AA stimulation. The maximum LSPR shifts measured within 240 s after AA stimulation are ∼1.2 nm and ∼0.9 nm for the single cells and the 3D spheroids, respectively. According to the calibration curve shown in Figure 4B, the LSPR shifts of 1.2 nm and 0.9 nm corresponds to ∼1–2 μm H2O2. In contrast, the HepG2 cells that are not stimulated by AA and the cell-free control groups, either with or without AA, do not secrete a measurable amount of H2O2 during the same period. The coefficient of variation (standard deviation/mean) of the calibration measurement at similar wavelength shift is about 15.4%. Therefore, the errors of the measured H2O2 concentrations in the experiments are estimated to be around 15.4%. In addition, the results also suggest that the refractive index variation of the medium during the cell culture was minimal and has minimal effects on the LSPR wavelength shift. Figures 5C,D show the comparison of the responses to the AA stimulation between the single cells and 3D spheroids. The unpaired Student’s t-test is performed to compare the results obtained from the experiments in which the cells are cultured in different formats. The results show that the single cells secret more H2O2 than the 3D spheroids after the AA stimulation.

FIGURE 5
www.frontiersin.org

FIGURE 5. Detection of H2O2 released from the single cells and the 3D spheroids. LSPR shifts of the plasmonic gel films incubated with sample solutions taken from (A) the single cells and (B) the 3D spheroids at different time points. The four groups of the experiment: (HepG2+ AA+) HepG2 cells stimulated by 1.5 μm AA; (HepG2+ AA) HepG2 cells not stimulated by 1.5 μm AA; (HepG2 AA+) cell-free MEM culture medium mixed with 1.5 μm AA; (HepG2 AA) cell-free MEM culture medium only. (C,D) Comparison of the responses to the AA stimulation between the single cells and the 3D spheroids. Error bars show standard deviations from 3 cell experiments, each of which was measured 5 times using the gel film. n.s: not significant, *p < 0.05, **p < 0.01, ***p < 0.001.

Discussion

The experimental results confirm the feasibility of the time-lapse H2O2 measurement from the complete medium collected from the cell culture. In addition, the quantitative measurement results show the different temporal H2O2 secretion between single cell and spheroid culture formats. During the AA stimulation, the H2O2 concentration in single-culture culture increases in a faster pace and reaches to a higher value comparing to that in spheroid culture. The H2O2 concentrations in both culture formats become similar after 4 min stimulation. The observation suggests that the culture format does affect the H2O2 secretion kinetics and maximum concentration; however, the format has less effects on the H2O2 concentration after an extended period. The slower H2O2 concentration increase may be resulted from the diffusion of AA through the 3D cell arrangements. In addition, it has been reported that oxygen tension can be greatly reduced within a spheroid due to limited diffusion and cell metabolism (Sarkar et al., 2018; Close and Johnston, 2021). The low oxygen tension may also impede the H2O2 production by the cells (Maddalena et al., 2017). The simultaneous measurement of oxygen tension and H2O2 can better help to elucidate the underlying molecular mechanisms.

Furthermore, AA has been intensively investigated as an anti-cancer drug and its roles in cancer treatment in recent decades. It has been identified that pharmacologic AA concentrations are capable of selectively killing cancer cells though various mechanisms. Among them, two mechanisms of anti-cancer activity with AA are well recognized: H2O2-induced oxidative stress and DNA demethylation mediated by activation (Shenoy et al., 2018). AA has been found to be able to generate and deliver H2O2 to tissues and in extracellular fluid based on in vitro cell culture and in vivo studies, and to decrease growth of aggressive tumor in animal experiments (Chen et al., 2005; Chen et al., 2007; Chen et al., 2008; Gao et al., 2019). However, due to the technical limitations, the in vitro experiments are limited to in-direct or end-point H2O2 measurement without kinetic information. Furthermore, comparison of the H2O2 generation between different cell culture formats are not systematically investigated. The integrated approach demonstrated in this paper opens a new window to better studied the H2O2 generation and variation in complete cell culture medium in a straightforward and rapid manner, which can greatly help scientists to investigate H2O2 related biomedical phenomena.

Conclusion

In this paper, an integrated approach is developed to compare the H2O2 secretion from living hepatocytes cultured in single cells and spheroids. The uniformed-sized cell spheroids are formed and cultured in the developed microfluidic device. The device allows the cell spheroids cultured in a reliable manner with easy medium exchange, and the spheroids can be harvested from the device with great integrity for the following analysis. The H2O2 in the complete cell culture medium is measured using a hydrogel-based LSPR substrate. Taking advantage of the enzyme-catalyzed chromogenic reaction and hydrogel-based substrate, the H2O2 can be detected with high specificity in a straightforward manner for the time-lapse measurement. The H2O2 secreted from the living cells (HepG2) cultured in single cells and spheroids are compared, and the results show the different secretion temporal patterns confirming the important roles of the culture formats. The developed approach provides a simple and useful tool to study H2O2 related biomedical topics.

Data Availability Statement

The raw data supporting the conclusion of this article will be made available by the authors, without undue reservation.

Author Contributions

Y-CT and Y-FC design the entire study and write the manuscript in close collaboration with other authors. Y-JS and C-CP perform the cell culture and hydrogen peroxide measurement experiments. Y-JS, Y-CT and Y-FC analyse the experimental results.

Funding

This work is supported by the Ministry of Science and Technology, Taiwan (106-2221-E-010-005-MY2, 107-2628-E-001-003-MY3, 108-2628-E-010-001-MY3). Y-JS was supported in part by the funding under the Memorandum of Understanding between National Yang-Ming University and Research Center for Applied Sciences at Academia Sinica, Taipei, Taiwan.

Conflict of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s Note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Acknowledgments

We thank Mr. Wei-Hao Liao for the help in the microfluidic device fabrication, and Ms. Yun-Chu Chen for the technical assistance.

References

Chen, Q., Espey, M. G., Krishna, M. C., Mitchell, J. B., Corpe, C. P., Buettner, G. R., et al. (2005). Pharmacologic Ascorbic Acid Concentrations Selectively Kill Cancer Cells: Action as a Pro-drug to Deliver Hydrogen Peroxide to Tissues. Proc. Natl. Acad. Sci. U.S.A. 102 (38), 13604–13609. doi:10.1073/pnas.0506390102

PubMed Abstract | CrossRef Full Text | Google Scholar

Chen, Q., Espey, M. G., Sun, A. Y., Lee, J.-H., Krishna, M. C., Shacter, E., et al. (2007). Ascorbate in Pharmacologic Concentrations Selectively Generates Ascorbate Radical and Hydrogen Peroxide in Extracellular Fluid In Vivo. Proc. Natl. Acad. Sci. U.S.A. 104 (21), 8749–8754. doi:10.1073/pnas.0702854104

PubMed Abstract | CrossRef Full Text | Google Scholar

Chen, Q., Espey, M. G., Sun, A. Y., Pooput, C., Kirk, K. L., Krishna, M. C., et al. (2008). Pharmacologic Doses of Ascorbate Act as a Prooxidant and Decrease Growth of Aggressive Tumor Xenografts in Mice. Proc. Natl. Acad. Sci. U.S.A. 105 (32), 11105–11109. doi:10.1073/pnas.0804226105

PubMed Abstract | CrossRef Full Text | Google Scholar

Chen, Y.-A., King, A. D., Shih, H.-C., Peng, C.-C., Wu, C.-Y., Liao, W.-H., et al. (2011). Generation of Oxygen Gradients in Microfluidic Devices for Cell Culture Using Spatially Confined Chemical Reactions. Lab. Chip 11 (21), 3626–3633. doi:10.1039/c1lc20325h

PubMed Abstract | CrossRef Full Text | Google Scholar

Chen, Y. C., Chen, J. J., Hsiao, Y. J., Xie, C. Z., Peng, C. C., Tung, Y. C., et al. (2021). Plasmonic Gel Films for Time-Lapse LSPR Detection of Hydrogen Peroxide Secreted from Living Cells. Sensors and Actuators B-Chemical 336. doi:10.1016/j.snb.2021.129725

CrossRef Full Text | Google Scholar

Close, D. A., and Johnston, P. A. (2022). Detection and Impact of Hypoxic Regions in Multicellular Tumor Spheroid Cultures Formed by Head and Neck Squamous Cell Carcinoma Cells Lines. SLAS Discov. 27, 39–54. doi:10.1016/j.slasd.2021.10.008

PubMed Abstract | CrossRef Full Text | Google Scholar

Conde de la Rosa, L., Schoemaker, M. H., Vrenken, T. E., Buist-Homan, M., Havinga, R., Jansen, P. L. M., et al. (2006). Superoxide Anions and Hydrogen Peroxide Induce Hepatocyte Death by Different Mechanisms: Involvement of JNK and ERK MAP Kinases. J. Hepatol. 44 (5), 918–929. doi:10.1016/j.jhep.2005.07.034

PubMed Abstract | CrossRef Full Text | Google Scholar

Feng, C., Wang, F., Dang, Y., Xu, Z., Yu, H., and Zhang, W. (2017). A Self-Assembled Ratiometric Polymeric Nanoprobe for Highly Selective Fluorescence Detection of Hydrogen Peroxide. Langmuir 33 (13), 3287–3295. doi:10.1021/acs.langmuir.7b00189

PubMed Abstract | CrossRef Full Text | Google Scholar

Gao, X., Wei, K., Hu, B., Xu, K., and Tang, B. (2019). Ascorbic Acid Induced HepG2 Cells' Apoptosis via Intracellular Reductive Stress. Theranostics 9 (14), 4233–4240. doi:10.7150/thno.33783

PubMed Abstract | CrossRef Full Text | Google Scholar

Gough, D. R., and Cotter, T. G. (2011). Hydrogen Peroxide: a Jekyll and Hyde Signalling Molecule. Cell Death Dis 2, e213. doi:10.1038/cddis.2011.96

PubMed Abstract | CrossRef Full Text | Google Scholar

Hirsch, I., Prell, E., and Weiwad, M. (2014). Assessment of Cell Death Studies by Monitoring Hydrogen Peroxide in Cell Culture. Anal. Biochem. 456, 22–24. doi:10.1016/j.ab.2014.04.009

PubMed Abstract | CrossRef Full Text | Google Scholar

Hsiao, A. Y., Torisawa, Y.-s., Tung, Y.-C., Sud, S., Taichman, R. S., Pienta, K. J., et al. (2009). Microfluidic System for Formation of PC-3 Prostate Cancer Co-culture Spheroids. Biomaterials 30 (16), 3020–3027. doi:10.1016/j.biomaterials.2009.02.047

PubMed Abstract | CrossRef Full Text | Google Scholar

Liu, Y., Liu, X., Guo, Z., Hu, Z., Xue, Z., and Lu, X. (2017). Horseradish Peroxidase Supported on Porous Graphene as a Novel Sensing Platform for Detection of Hydrogen Peroxide in Living Cells Sensitively. Biosens. Bioelectron. 87, 101–107. doi:10.1016/j.bios.2016.08.015

PubMed Abstract | CrossRef Full Text | Google Scholar

Ma, X., Han, S., Zhang, W., Fan, Y.-J., Liu, M.-N., Liu, A.-Y., et al. (2015). Protection of Cultured Human Hepatocytes from Hydrogen Peroxide-Induced Apoptosis by Relaxin-3. Mol. Med. Rep. 11 (2), 1228–1234. doi:10.3892/mmr.2014.2842

PubMed Abstract | CrossRef Full Text | Google Scholar

Maddalena, L. A., Selim, S. M., Fonseca, J., Messner, H., McGowan, S., and Stuart, J. A. (2017). Hydrogen Peroxide Production Is Affected by Oxygen Levels in Mammalian Cell Culture. Biochem. Biophysical Res. Commun. 493 (1), 246–251. doi:10.1016/j.bbrc.2017.09.037

CrossRef Full Text | Google Scholar

Milkovic, L., Cipak Gasparovic, A., Cindric, M., Mouthuy, P.-A., and Zarkovic, N. (2019). Short Overview of ROS as Cell Function Regulators and Their Implications in Therapy Concepts. Cells 8 (8), 793. doi:10.3390/cells8080793

PubMed Abstract | CrossRef Full Text | Google Scholar

Miller, I. P., Pavlović, I., Poljšak, B., Šuput, D., and Milisav, I. (2019). Beneficial Role of ROS in Cell Survival: Moderate Increases in H2O2 Production Induced by Hepatocyte Isolation Mediate Stress Adaptation and Enhanced Survival. Antioxidants 8 (10), 434. doi:10.3390/antiox8100434

PubMed Abstract | CrossRef Full Text | Google Scholar

Mulas, C., Hodgson, A. C., Kohler, T. N., Agley, C. C., Humphreys, P., Kleine-Brüggeney, H., et al. (2020). Microfluidic Platform for 3D Cell Culture with Live Imaging and Clone Retrieval. Lab. Chip 20 (14), 2580–2591. doi:10.1039/d0lc00165a

PubMed Abstract | CrossRef Full Text | Google Scholar

Nindl, G., Peterson, N. R., Hughes, E. F., Waite, L. R., and Johnson, M. T. (2004). Effect of Hydrogen Peroxide on Proliferation, Apoptosis and Interleukin-2 Production of Jurkat T Cells. Biomed. Sci. Instrum. 40, 123–128.

PubMed Abstract | Google Scholar

Patra, B., Peng, C. C., Liao, W. H., Lee, C. H., and Tung, Y. C. (2016). Drug Testing and Flow Cytometry Analysis on a Large Number of Uniform Sized Tumor Spheroids Using a Microfluidic Device. Sci. Rep. 6, 21061. doi:10.1038/srep21061

PubMed Abstract | CrossRef Full Text | Google Scholar

Patra, B., Chen, Y.-H., Peng, C.-C., Lin, S.-C., Lee, C.-H., and Tung, Y.-C. (2013). A Microfluidic Device for Uniform-Sized Cell Spheroids Formation, Culture, Harvesting and Flow Cytometry Analysis. Biomicrofluidics 7 (5), 054114. doi:10.1063/1.4824480

CrossRef Full Text | Google Scholar

Patra, B., Peng, Y.-S., Peng, C.-C., Liao, W.-H., Chen, Y.-A., Lin, K.-H., et al. (2014). Migration and Vascular Lumen Formation of Endothelial Cells in Cancer Cell Spheroids of Various Sizes. Biomicrofluidics 8 (5), 052109. doi:10.1063/1.4895568

PubMed Abstract | CrossRef Full Text | Google Scholar

Peng, C.-C., Liao, W.-H., Chen, Y.-H., Wu, C.-Y., and Tung, Y.-C. (2013). A Microfluidic Cell Culture Array with Various Oxygen Tensions. Lab. Chip 13 (16), 3239–3245. doi:10.1039/c3lc50388g

PubMed Abstract | CrossRef Full Text | Google Scholar

Polidoro, M. A., Ferrari, E., Marzorati, S., Lleo, A., and Rasponi, M. (2021). Experimental Liver Models: From Cell Culture Techniques to Microfluidic Organs‐on‐chip. Liver Int. 41 (8), 1744–1761. doi:10.1111/liv.14942

PubMed Abstract | CrossRef Full Text | Google Scholar

Queiroz, R. F., Stanley, C. P., Wolhuter, K., Kong, S. M. Y., Rajivan, R., McKinnon, N., et al. (2021). Hydrogen Peroxide Signaling via its Transformation to a Stereospecific Alkyl Hydroperoxide that Escapes Reductive Inactivation. Nat. Commun. 12 (1), 6626. doi:10.1038/s41467-021-26991-5

PubMed Abstract | CrossRef Full Text | Google Scholar

Sarkar, S., Peng, C. C., and Tung, Y. C. (2020). Comparison of VEGF-A Secretion from Tumor Cells under Cellular Stresses in Conventional Monolayer Culture and Microfluidic Three-Dimensional Spheroid Models. Plos One 15 (11), e0240833. doi:10.1371/journal.pone.0240833

PubMed Abstract | CrossRef Full Text | Google Scholar

Sarkar, S., Peng, C.-C., Kuo, C. W., Chueh, D.-Y., Wu, H.-M., Liu, Y.-H., et al. (2018). Study of Oxygen Tension Variation within Live Tumor Spheroids Using Microfluidic Devices and Multi-Photon Laser Scanning Microscopy. RSC Adv. 8 (53), 30320–30329. doi:10.1039/c8ra05505j

CrossRef Full Text | Google Scholar

Shenoy, N., Creagan, E., Witzig, T., and Levine, M. (2018). Ascorbic Acid in Cancer Treatment: Let the Phoenix Fly. Cancer Cell 34 (5), 700–706. doi:10.1016/j.ccell.2018.07.014

PubMed Abstract | CrossRef Full Text | Google Scholar

Sun, Y., Luo, M., Meng, X., Xiang, J., Wang, L., Ren, Q., et al. (2017). Graphene/Intermetallic PtPb Nanoplates Composites for Boosting Electrochemical Detection of H2O2 Released from Cells. Anal. Chem. 89 (6), 3761–3767. doi:10.1021/acs.analchem.7b00248

PubMed Abstract | CrossRef Full Text | Google Scholar

Torisawa, Y.-s., Takagi, A., Nashimoto, Y., Yasukawa, T., Shiku, H., and Matsue, T. (2007). A Multicellular Spheroid Array to Realize Spheroid Formation, Culture, and Viability Assay on a Chip. Biomaterials 28 (3), 559–566. doi:10.1016/j.biomaterials.2006.08.054

PubMed Abstract | CrossRef Full Text | Google Scholar

Tung, Y.-C., Hsiao, A. Y., Allen, S. G., Torisawa, Y.-s., Ho, M., and Takayama, S. (2011). High-throughput 3D Spheroid Culture and Drug Testing Using a 384 Hanging Drop Array. Analyst 136 (3), 473–478. doi:10.1039/c0an00609b

PubMed Abstract | CrossRef Full Text | Google Scholar

Velusamy, N., Thirumalaivasan, N., Bobba, K. N., Podder, A., Wu, S.-P., and Bhuniya, S. (2019). FRET-based Dual Channel Fluorescent Probe for Detecting Endogenous/exogenous H2O2/H2S Formation through Multicolor Images. J. Photochem. Photobiol. B: Biol. 191, 99–106. doi:10.1016/j.jphotobiol.2018.12.016

PubMed Abstract | CrossRef Full Text | Google Scholar

Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., and Ingber, D. E. (2001). Soft Lithography in Biology and Biochemistry. Annu. Rev. Biomed. Eng. 3, 335–373. doi:10.1146/annurev.bioeng.3.1.335

PubMed Abstract | CrossRef Full Text | Google Scholar

Xia, Y., and Whitesides, G. M. (1998). Soft Lithography. Angew. Chem. Int. Edition 37 (5), 550–575. doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g

CrossRef Full Text | Google Scholar

Xie, H., Li, Y.-T., Lei, Y.-M., Liu, Y.-L., Xiao, M.-M., Gao, C., et al. (2016). Real-time Monitoring of Nitric Oxide at Single-Cell Level with Porphyrin-Functionalized Graphene Field-Effect Transistor Biosensor. Anal. Chem. 88 (22), 11115–11122. doi:10.1021/acs.analchem.6b03208

PubMed Abstract | CrossRef Full Text | Google Scholar

Xin, Q., Liu, Q., Shah, H., and Gong, J. R. (2017). Electron Spin Resonance and Fluorescence Imaging Assisted Electrochemical Approach for Accurate and Comprehensive Monitoring of Cellular Hydrogen Peroxide Dynamics. Analyst 142 (2), 316–325. doi:10.1039/c6an02006b

PubMed Abstract | CrossRef Full Text | Google Scholar

Zamprogno, P., Wüthrich, S., Achenbach, S., Thoma, G., Stucki, J. D., Hobi, N., et al. (2021). Second-generation Lung-On-A-Chip with an Array of Stretchable Alveoli Made with a Biological Membrane. Commun. Biol. 4 (1), 168. doi:10.1038/s42003-021-01695-0

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhang, T., Gu, Y., Li, C., Yan, X., Lu, N., Liu, H., et al. (2017). Fabrication of Novel Electrochemical Biosensor Based on Graphene Nanohybrid to Detect H2O2 Released from Living Cells with Ultrahigh Performance. ACS Appl. Mater. Inter. 9 (43), 37991–37999. doi:10.1021/acsami.7b14029

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhao, Y., Hu, Y., Hou, J., Jia, Z., Zhong, D., Zhou, S., et al. (2019). Electrochemical Biointerface Based on Electrodeposition AuNPs on 3D Graphene Aerogel: Direct Electron Transfer of Cytochrome C and Hydrogen Peroxide Sensing. J. Electroanalytical Chem. 842, 16–23. doi:10.1016/j.jelechem.2019.04.052

CrossRef Full Text | Google Scholar

Keywords: localized surface plasmon resonance, agarose gel, hydrogen peroxide, enzyme-catalyzed reaction, 3D cell culture, microfluidics

Citation: Siao Y-J, Peng C-C, Tung Y-C and Chen Y-F (2022) Comparison of Hydrogen Peroxide Secretion From Living Cells Cultured in Different Formats Using Hydrogel-Based LSPR Substrates. Front. Bioeng. Biotechnol. 10:869184. doi: 10.3389/fbioe.2022.869184

Received: 04 February 2022; Accepted: 22 March 2022;
Published: 08 April 2022.

Edited by:

Tuhin Subhra Santra, Indian Institute of Technology Madras, India

Reviewed by:

Chunsheng Wu, Xi’an Jiaotong University, China
Guangyu Qiu, ETH Zürich, Switzerland

Copyright © 2022 Siao, Peng, Tung and Chen. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Yi-Chung Tung, tungy@gate.sinica.edu.tw; Yih-Fan Chen, chenyf@nycu.edu.tw

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.