AUTHOR=Mazur Michael J. , Metchev Stanimir , Brown Rachel A. , Gupta Ridhee , Bloch Richard , Mills Tristan , Pass Emily TITLE=The colibri telescope array for KBO detection through serendipitous stellar occultations: A technical description JOURNAL=Frontiers in Astronomy and Space Sciences VOLUME=9 YEAR=2022 URL=https://www.frontiersin.org/journals/astronomy-and-space-sciences/articles/10.3389/fspas.2022.929573 DOI=10.3389/fspas.2022.929573 ISSN=2296-987X ABSTRACT=

We present the technical design, construction and testing of the Colibri telescope array at Elginfield Observatory near London, Ontario, Canada. Three 50-cm telescopes are arranged in a triangular array and are separated by 110–160 m. During operation, they will monitor field stars at the intersections of the ecliptic and galactic plane for serendipitous stellar occultations (SSOs) by trans-Neptunian objects (TNOs). At a frame rate of 40 frames per second (fps), Fresnel diffraction in the occultation light curve can be resolved and, with coincident detections, be used to estimate basic properties of the occulting object. Using off-the-shelf components, the Colibri system streams imagery to disk at a rate of 1.5 GB/s for next-day processing by a custom occultation detection pipeline.

The imaging system has been tested and is found to perform well, given the moderate site conditions. Limiting magnitudes at 40 fps are found to be about 12.1 (temporal SNR = 5, visible light Gaia G band) with time-series standard deviations ranging from about 0.035 mag to >0.2 mag. SNR is observed to decrease linearly with magnitude for stars fainter than about G = 9.5 mag. Brighter than this limit, SNR is constant, suggesting that atmospheric scintillation is the dominant noise source. Astrometric solutions show errors typically less than ±0.3 pixels (0.8 arc seconds) without a need for high-order corrections.