AUTHOR=Ren Yue , Duhatschek Douglas , Bartolomeu C. C. , Laplacette Ana L. , Perez Martin M. , Rial Clara , Erickson David , Giordano Julio O. TITLE=An automated system for cattle reproductive management under the IoT framework. Part II: Induction of luteinizing hormone release after gonadotropin releasing hormone analogue delivery with e-Synch JOURNAL=Frontiers in Animal Science VOLUME=4 YEAR=2023 URL=https://www.frontiersin.org/journals/animal-science/articles/10.3389/fanim.2023.1093857 DOI=10.3389/fanim.2023.1093857 ISSN=2673-6225 ABSTRACT=

Technologies for automating animal management and monitoring tasks can improve efficiency and productivity of livestock production. We developed the e-Synch system for automated control and monitoring the estrous cycle of cattle through intravaginal hormone delivery and sensing. Thus, our objective was to evaluate luteinizing hormone (LH) concentrations after intravaginal instillation of the Gonadotropin-releasing hormone (GnRH) analogue Gonadorelin with the e-Synch system. This system consists of an intravaginal electronically controlled automated hormone delivery and sensing device integrated with an IoT platform. Lactating Holstein cows with their estrous cycle synchronized were used in two experiments (Exp). In Exp 1, at 48 h after induction of luteolysis, cows (n=5-6 per group) were randomized to receive 100 µg of Gonadorelin through intramuscular (i.m.) injection, 100 µg of Gonadorelin in a 2 mL solution delivered with e-Synch, and an empty e-Synch device. In Exp 2, at 48 h after induction of luteolysis cows (n=6-7 per group) were randomized to receive 100 µg of Gonadorelin i.m., or an intravaginal treatment with e-Synch consisting of 100 or 1,000 µg of Gonadorelin in 2 or 10 mL of solution containing 10% citric acid as absorption enhancer. Circulating concentrations of LH were analyzed with linear mixed models with or without repeated measurements. In Exp 1, cows in the i.m. Gonadorelin treatment had a surge of LH whereas cows in the other two treatments did not have a surge of LH for up to 8 h after treatment. In Exp 2, the 1,000 µg dose of Gonadorelin elicited more LH release than the 100 µg dose, regardless of solution quantity. The overall LH response as determined by area under the curve, mean, and maximum LH concentrations was similar between cows receiving 1,000 µg of Gonadorelin delivered with e-Synch and 100 μg of Gonadorelin i.m. Increasing volume of solution for delivering the same dose of Gonadorelin partially increased LH release only for the 100 µg dose. We conclude that the e-Synch system could be used to automatically release Gonadorelin in a dose and volume that induces a surge of LH of similar magnitude than after i.m. injection of 100 μg of Gonadorelin. Also, the dose of Gonadorelin delivered by e-Synch is more critical than the volume of solution used.