
95% of researchers rate our articles as excellent or good
Learn more about the work of our research integrity team to safeguard the quality of each article we publish.
Find out more
ORIGINAL RESEARCH article
Front. Aging
Sec. Musculoskeletal Aging
Volume 6 - 2025 | doi: 10.3389/fragi.2025.1560097
This article is part of the Research Topic Women at the Forefront of Musculoskeletal Aging Science View all articles
The final, formatted version of the article will be published soon.
You have multiple emails registered with Frontiers:
Please enter your email address:
If you already have an account, please login
You don't have a Frontiers account ? You can register here
With the advancement of studies on the importance of sarcopenia in the aging process, new technologies have been developed to assess muscle mass and function.However, most research on portable devices has not considered a wide range of ages and clinical conditions. This study aimed to evaluate the reliability of the Gripwise digital dynamometer in measuring handgrip strength in older Brazilian adults, comparing its performance with the widely used Saehan device. Methods: A cross-sectional study was conducted with 149 participants (32 men and 117 women), with an average age of 69.5 years. Handgrip strength was measured using both the Gripwise and Saehan dynamometers. Reliability was assessed using the intraclass correlation coefficient (ICC). Analyses considered three handgrip strength measurements from both devices, as well as the highest value obtained. The classification of dynapenia (low muscle strength) was compared using different cutoff points proposed by Villain et al. (2023), Spexoto et al. (2022), and Cruz-Jentoft et al. (2019). Results: Both dynamometers demonstrated excellent reliability, with ICC values above 0.90. However, significant differences in mean handgrip strength values were observed between the devices (approximately 3.5 to 4 kgf). These variations impacted the classification of dynapenia, with the Gripwise identifying more cases of low muscle strength compared to Saehan. Conclusion: The lower values reported by the Gripwise may impact clinical decision-making in two ways. On one hand, lower values may lead to earlier detection of muscle weakness, allowing for quicker intervention in individuals with strength below typical thresholds. However, this could also result in an overestimation of the prevalence of dynapenia if the values do not accurately reflect true muscle strength, which could lead to unnecessary interventions.Therefore, it is crucial to consider the need for adjustments in the cutoff points when using Gripwise. These findings highlight the need to revise cutoff points for dynapenia classification, considering device variations and model differences in older age groups.
Keywords: handgrip strength, Dynamometer, dynapenia, Aging, Reliability
Received: 13 Jan 2025; Accepted: 04 Apr 2025.
Copyright: © 2025 Benatti De Oliveira, Vilar Fernandes, Amaral, Junqueira Vasques and Pires Corona. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
* Correspondence:
Gabriela Benatti De Oliveira, Faculty of Medical Sciences, State University of Campinas, Campinas, Brazil
Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.
Research integrity at Frontiers
Learn more about the work of our research integrity team to safeguard the quality of each article we publish.