Skip to main content

BRIEF RESEARCH REPORT article

Front. Toxicol., 25 July 2023
Sec. In Vitro Toxicology

Experimental exposure assessment for in vitro cell-based bioassays in 96- and 384-well plates

Julia HuchthausenJulia Huchthausen1Maria KnigMaria König1Beate I. Escher,Beate I. Escher1,2Luise Henneberger
Luise Henneberger1*
  • 1Department of Cell Toxicology, Helmholtz Centre for Environmental Research—UFZ, Leipzig, Germany
  • 2Department of Geosciences, Environmental Toxicology, Eberhard Karls University Tübingen, Tübingen, Germany

In vitro cell-based bioassays have great potential for applications in the human health risk assessment of chemicals. The quantification of freely dissolved concentrations (Cfree) in in vitro assays is essential to generate reliable data for in vitro-to-in vivo extrapolation. Existing methods for the quantification of Cfree are limited to low-throughput microtiter plates. The present study is a proof of principle for the applicability of a solid-phase microextraction (SPME) method for the determination of Cfree in the peroxisome proliferator-activated receptor gamma (PPARγ) bioassay run in 384-well plates with 80 µL medium per well. The effect concentrations obtained from 384-well plates were compared with those obtained from 96-well plates in a previous study. Nominal effect concentrations obtained using 96- and 384-well plates agreed with each other within a factor of three, and freely dissolved effect concentrations agreed within a factor of 6.5. The good degree of agreement in the results from both plate formats proves the general applicability of the SPME method for the determination of Cfree for bioassays in 384-well plates, making the present study a first step toward exposure assessment in high-throughput bioassays.

1 Introduction

Chemicals are omnipresent in today’s world. People are exposed to a mix of thousands of different chemicals that could have unknown consequences for human health. For this reason, thorough risk assessment is essential to determine the possible consequences of human exposure to chemicals (Rice et al., 2008). Cell-based bioassays have gained popularity in the field of toxicology in recent years. With the initiation of the “Toxicity Testing in the 21st Century” (Tox21) program in 2007, the US National Research Council paved the way for in vitro bioassays as alternatives to animal testing (US National Research Council, 2007).

Cell-based bioassays allow for automatization, making them a cost-effective and time-saving method for the assessment of effects. However, chemical exposure during the assay must be monitored in order to obtain biologically relevant data (Gülden et al., 2002; Henneberger et al., 2019b; Huchthausen et al., 2020). Complementary to the typically used nominal concentration (Cnom), freely dissolved concentration (Cfree) in the assay medium should be used as a concentration metric if chemical losses, e.g., due to sorption to medium components, cannot be excluded (Groothuis et al., 2015).

Various mass balance models are available to predict Cfree (Armitage et al., 2021; Proença et al., 2021). However, previous studies from our group have shown that, especially for ionizable chemicals, model predictions can deviate widely from experimental values (Henneberger et al., 2020; Huchthausen et al., 2020). Measuring Cfree during the assay at effective concentrations has been demonstrated to be especially important for ionizable chemicals that show non-linear binding to medium proteins (Henneberger et al., 2019a; Henneberger et al., 2019b; Huchthausen et al., 2020).

We have previously developed a method integrating exposure assessment of single chemicals with diverse physicochemical properties and chemical mixtures into a routine bioassay workflow in 96-well plates (Henneberger et al., 2019b; Huchthausen et al., 2020; Henneberger et al., 2022). Solid-phase microextraction (SPME) was established by Heringa et al. (2003) to be a suitable method for experimental exposure assessment and has been shown to be a good method for measurement of Cfree in bioassay medium aliquots from 96-well plates (Henneberger et al., 2019b; Huchthausen et al., 2020). Cell-based bioassays are often performed in automated high-throughput screening (HTS) systems using 384- or 1,536-well plates (Inglese and Auld, 2008). High-tier well plate formats allow higher sample throughput without a linear increase in costs (Kolb and Neumann, 1997); however, they are more challenging with regard to exposure assessment due to the low sample volume (of typically 40–80 μL for 384-well plates and 6–10 µL for 1,536-well plates), the higher surface area, and the large number of samples per plate.

The aim of this work was to prove that the existing method for the determination of Cfree for 96-well plates can be adapted to bioassay medium aliquots from 384-well plates. The assay used for optimization was the peroxisome proliferator-activated receptor gamma (PPARγ) assay representing the chemical activation of human lipid metabolism. Nine previously tested PPARγ activators were selected, for which Cfree had already been determined experimentally in 96-well plates (Huchthausen et al., 2020). The intent of this study was to demonstrate the general comparability of the measured Cfree values obtained from both plate formats.

2 Materials and methods

2.1 Solvents and chemicals

To compare the effect concentrations obtained from bioassays conducted in 96- and 384-well plates, nine chemicals previously identified as PPARγ activators (Henneberger et al., 2019b; Huchthausen et al., 2020) were tested: caffeine (neutral), lamotrigine (base), six acids (diclofenac, 2,4-dichlorophenoxyacetic acid (2,4-D), naproxen, ibuprofen, torasemide, and warfarin), and telmisartan (multifunctional). The chemical class, logarithmic liposome–water distribution ratio (log Dlip/w), acidity constant (pKa), and speciation at pH 7.4 of each of the test chemicals are shown in Table 1. Information on the measurement of pKa is provided in Supplementary Data Sheet 1 (Text S1). Further information on the chemicals can be found in Supplementary Data Sheet 1 (Table S1).

TABLE 1
www.frontiersin.org

TABLE 1. Test chemicals, their logarithmic liposome–water distribution ratio (log Dlip/w), their chemical class, pKa, and speciation at pH 7.4.

LC-MS-grade acetonitrile, isopropanol (CHEMSOLUTE), methanol, and formic acid (Honeywell) with ≥99.9% purity were used. Deionized water was obtained using a Milli-Q water purification system (Merck).

2.2 In vitro bioassay

The GeneBLAzer PPARγ-UAS-bla HEK 293H cell line was purchased from Thermo Fisher Scientific (catalog number K1419). Cells were seeded at 6,500 cells per well in 30 μL PPARγ assay medium (98% Opti-MEM, 2% charcoal-stripped fetal bovine serum (FBS), 100 U/mL penicillin–streptomycin, and 10 mM HEPES) in BioCoat™ TC-treated 384-well microplates with a poly-D-lysine coating from Corning (catalog number 356663) and incubated at 37°C, 5% CO2, and 100% humidity for 24 h. All chemicals were tested in duplicate in linear dilution in the PPARγ assay. In a glass-coated 96-well plate (Thermo Fisher Scientific, catalog number 60180-P300), 150 µL PPARγ assay medium per well was spiked with different chemical concentrations using a digital dispenser (D300e, Tecan). Subsequently, 50 μL spiked assay medium was transferred manually in duplicate from each well of the 96-well dosing plate to the 384-well cell plate, leading to a total volume of 80 µL per well. After dosing, the cells were incubated at 37°C, 5% CO2, and 100% humidity for 24 h. The confluency of the cells was measured before and 24 h after dosing using an Incucyte S3 Automated Live-Cell Imager (Essen BioScience) to determine cell viability. PPARγ activation was detected using the LiveBLAzer™ FRET-B/G Loading Kit from Thermo Fisher Scientific (catalog number K1095). The protocol for the PPARγ assay is described in detail in Neale et al. (2017). Medium aliquots of 30 µL from the highest concentration in the dosing plate (t = 0 h) and each well of the cell plate after 24-h incubation (t = 24 h) were transferred to amber glass vials with inserts from LABSOLUTE (catalog number 7648146) for the determination of Cfree.

2.3 Determination of Cfree

Custom-made metal alloy SPME fibers from Sigma-Aldrich coated with C18/polyacrylonitrile (approximately 30 mm total length, 2 mm coating length, 45 µm coating thickness, and approximately 69 nL coating volume), were used.

The fibers were conditioned in methanol for 24 h and in Milli-Q water for 20 min. They were immersed into the medium aliquots (30 µL) and incubated at 37°C and 1,800 rpm (BioShake iQ, QInstruments) for 24 h. The fibers were moved to a new vial containing 60 µL of the respective desorption solvent (Supplementary Table S1) and desorbed at 37°C and 1,800 rpm for 2 h. The protocol for the SPME method is described in detail in Henneberger et al. (2019a). Controls in phosphate-buffered saline (PBS) were run separately for each chemical to determine the fiber–water distribution ratio (Df/w).

The chemical concentration in the PBS controls and the desorption solution of all samples was determined using an Agilent 1260 Infinity II liquid chromatograph coupled to an Agilent 6420 Triple Quad mass spectrometer equipped with a Luna Omega Polar C18 column, a BioZen peptide PS-C18 column, or a Kinetex C18 column. Further details on the instrumentation can be found in Supplementary Data Sheet 1 (Tables S2 and S3). Acetonitrile blanks and standard solutions in the respective solvent (1–10,000 ng/mL) were measured with the samples.

2.4 Data evaluation

To obtain concentration response curves (CRCs) from the bioassay results, Cnom or Cfree values were plotted against the measured effects. The nominal or freely dissolved concentration leading to a cytotoxicity of 10% is the IC10 or IC10,free value; this was calculated from the slope of the linear part of the CRC using Eq. 1. The standard error of the IC10 or IC10,free was calculated using Eq. 2 (Escher et al., 2018).

IC10,free=10%slope,(1)
SEIC10,free=10%slope2×SEslope.(2)

The reference chemical for the PPARγ assay was rosiglitazone. This was dosed in duplicate on each plate in addition to the test chemicals to determine the maximum effect. The nominal or freely dissolved concentration leading to 10% of the maximum effect is referred to as the EC10 or EC10,free, respectively. This value was calculated from the linear part of the CRC at concentrations below IC10 or IC10,free using Eq. 3. The standard error of the EC10 was calculated using Eq. 4.

IC10,free=10%slope,(3)
SEIC10,free=10%slope2×SEslope.(4)

The concentration of the test chemical in the SPME fiber (Cf) was calculated using Eq. 5. Cdes represents the concentration in the desorption solution, Vdes represents the volume of the desorption solution, and Vf represents the volume of the fiber coating.

Cf=Cdes×VdesVf.(5)

The Df/w value was determined from PBS controls using Eq. 6. Cw represents the chemical concentration in the PBS phase after SPME.

Dfw=CfCw.(6)

Cfree in the medium aliquots was calculated using Eq. 7 (Henneberger et al., 2019b). The total amount of the chemical (ntotal) was calculated from Cnom.

Cfree=ntotalDfw×ntotalCfVf.(7)

3 Results and discussion

The measured effects (cytotoxicity and PPARγ activation) were plotted against Cnom and Cfree. CRCs for all chemicals are shown in Supplementary Data Sheet 1 (Figure S1).

Seven of the nine test chemicals were cytotoxic (all except naproxen and torasemide), and all activated PPARγ. Comparisons of the nominal IC10 and EC10 to the measured IC10,free and EC10,free are presented in Table 2.

TABLE 2
www.frontiersin.org

TABLE 2. Nominal and freely dissolved effect concentrations of the test chemicals as measured in experiments conducted in 384-well plates. IC10,nom or IC10,free: Nominal or freely dissolved concentration leading to a cytotoxicity of 10%. EC10,nom or EC10,free: Nominal concentration leading to 10% of the maximum effect. CV: Coefficient of variation.

For neutral hydrophilic chemicals (lamotrigine and caffeine), the difference between the nominal and freely dissolved effect concentrations determined was less than a factor of 1.3, as these do not bind strongly to proteins or lipids of the assay medium (Henneberger et al., 2019b). For most of the acidic chemicals (diclofenac, naproxen, warfarin, and torasemide), the deviation between the IC10 and IC10,free was also less than a factor of 2, but for the EC10 and EC10,free, the deviation was much higher (up to a factor of 30). This difference is caused by the non-linear binding of acidic chemicals to medium proteins, resulting in higher binding affinity and consequently a lower free fraction of the chemical at low concentrations (Henneberger et al., 2019a; Qin et al., 2023).

To test the applicability of the developed SPME method for the determination of freely dissolved effect concentrations for bioassays run in 384-well plates, the effect concentrations determined in the present study (freely dissolved and nominal) were compared with those from a previous study using 96-well plates (Huchthausen et al., 2020) (Table 3).

TABLE 3
www.frontiersin.org

TABLE 3. Nominal and freely dissolved effect concentrations of the test chemicals as measured in experiments conducted in 96-well plates plates [Adapted with permission from Huchthausen et al. (2020). Copyright (2020) American Chemical Society]. IC10,nom or IC10,free: Nominal or freely dissolved concentration leading to a cytotoxicity of 10%. EC10,nom or EC10,free: Nominal concentration leading to 10% of the maximum effect. CV: Coefficient of variation.

All IC10 values determined in 384-well plates differed by less than a factor of 2 from the IC10 values determined in 96-well plates. However, not all chemicals showed cytotoxicity in both plate formats. Naproxen was non-cytotoxic up to a concentration of 3.86 × 10−4 M in both plate types; torasemide had an IC10 value of 1.84 × 10−4 M in 96-well plates but did not show cytotoxicity up to 3.75 × 10−4 M in 384-well plates; and no IC10 value could be measured for 2,4-D or diclofenac in 96-well plates, but their IC10 values were 1.60 × 10−4 M and 4.99 × 10−5 M, respectively, in 384-well plates. The EC10 values measured in 384- and 96-well plates also deviated from one another by less than a factor of 2, with the exception of torasemide, for which the EC10 value deviated by a factor of 3 (Figure 1).

FIGURE 1
www.frontiersin.org

FIGURE 1. Comparison of (A) logarithmic nominal effect concentrations (log IC10 or log EC10) and (B) logarithmic freely dissolved effect concentrations (log IC10,free or log EC10,free) as determined in 96- and 384-well plates. The IC10 and EC10 values and IC10,free and EC10,free values for 96-well plates have been previously published (Huchthausen et al., 2020). The black solid line indicates a 1:1 correlation between the values; the black dashed lines indicate deviations from this by a factor of 10. Error bars indicate the standard deviation of the effect concentration values, but are often smaller than the size of the data points.

The IC10,free and EC10,free values determined in the present study were also consistent with our previous results from 96-well plates (Huchthausen et al., 2020). The IC10,free values for warfarin, ibuprofen, lamotrigine, and caffeine determined based on 30 µL aliquots from 384-well plates differed by less than a factor of 2 from the concentrations determined based on 180 µL aliquots from 96-well plates (Huchthausen et al., 2020). For telmisartan, the ratio between the determined IC10,free values was slightly higher, with deviation by a factor of 4. EC10,free values determined in each of the two well plate formats were also within a factor of 2 for most of the chemicals, with the exceptions of 2,4-D (whose values deviated by a factor of 4.4) and naproxen, which showed the highest deviation with a factor of 6.5. The higher deviations seen in the case of EC10,free values compared to IC10,free values could have been caused by higher measurement errors in the LC-MS/MS analysis at low concentrations, since the EC10,free values were often orders of magnitude lower than the IC10,free values. Specifically, naproxen is highly bound to proteins at low concentrations, leading to freely dissolved concentrations close to the limit of quantification (Henneberger et al., 2019a).

Comparing the relative standard deviations of the effect concentrations, it is noticeable that the coefficient of variation was generally higher in the case of 384-well plate measurements for both nominal and freely dissolved effect concentrations (Table 2; Table 3). This may have been caused by experimental inaccuracies due to the lower sample volume.

Additionally, an unpaired t-test was performed for a more detailed comparison of nominal and freely dissolved effect concentrations obtained using both plate formats (Supplementary Data Sheet 1: Figure S2; Supplementary Table S4). This t-test indicated that there was no significant difference between the plate formats (p-value >0.05) for the majority of effect concentrations, both nominal and freely dissolved. There was a significant difference between the effect concentrations measured in 96- and 384-well plates for torasemide and warfarin (nominal concentration); diclofenac, naproxen, and ibuprofen (freely dissolved concentration); and lamotrigine and telmisartan (both measures). However, the difference between the two plate formats was not highly significant for most of the chemicals and effect concentrations, with the exception of telmisartan. These differences might therefore have been caused by variations in the bioassay setup and by biological variability.

4 Conclusion

Measurement of freely dissolved effect concentrations is necessary for quantitative in vitro-to-in vivo extrapolation (QIVIVE) and to increase the relevance of in vitro tests for risk assessment (Villeneuve et al., 2019). For several test chemicals examined in the present study and in our previous publication, measurement of Cfree at all dosed concentrations was found to be the best method of deriving the freely dissolved effect concentration (Huchthausen et al., 2020), given that non-linear sorption isotherms are only available for a small number of chemicals and currently available in vitro exposure models are not applicable if the chemical concentration decreases over time.

The results of the present study show that the previously developed SPME method can also be applied to sample volumes as small as 30 µL from 384-well plates without changing the assay workflow or reducing sample throughput. Through the use of 384-well plates, sample throughput can be quadrupled compared to 96-well plates, making these results the first step in the development of a high-throughput SPME method for the determination of Cfree in bioassay medium aliquots. The advantages of the SPME method over more conventional methods, such as rapid equilibrium dialysis (RED), are the plastic-free system and the use of samples without dilution. The next step will be to automate the SPME method, because the high number of samples resulting from the use of 384-well plates cannot easily be handled manually. Automation could significantly speed up concentration measurement, so that the throughput of the chemical analysis would become similar to the throughput of the bioassays. We recently developed an automated SPME workflow using a Supel™ BioSPME 96-Pin Device (Supelco); however, the method is still limited to comparably high sample volumes (600 µL) in 96 deep-well plates (Huchthausen et al., 2022).

In summary, we have demonstrated that the previously published method for concentration measurements in 96-well plates is applicable for high-throughput assays conducted in 384-well plates without modification of the assay procedure. Cfree can be determined from small medium aliquots as low as 30 µL in parallel to the assay to provide nominal effect concentrations and freely dissolved effect concentrations for QIVIVE. The validation conducted in this proof-of-principle study was only performed in one bioassay with a small number of chemicals. For a complete validation, the comparison of a wide range of chemicals with diverse physicochemical properties and in different assays using media with different FBS contents is necessary. However, by establishing and automating this method, exposure assessment can be simplified, and more meaningful toxicity data can be generated on a routine basis.

Data availability statement

The original contributions presented in the study are included in the article/Supplementary Material; further inquiries can be directed to the corresponding author.

Author contributions

JH is the first author of the submitted manuscript. She conducted the experiments, evaluated the data, prepared the figures and tables, and wrote the manuscript. MK conducted the in vitro bioassay and reviewed the manuscript. BE conceptualized the experiments, supervised the work, and reviewed the manuscript. LH is the last author of the work. She conceptualized and designed the experiments, supervised the work, and reviewed the manuscript. All authors contributed to the article and approved the submitted version.

Funding

This study was supported by the CEFIC Long-Range Research Initiative (LRI), project ECO36.

Acknowledgments

We would like to thank Sophia Mälzer for supporting the SPME experiments. We also gratefully acknowledge funding of access to the platform CITEPro (Chemicals in the Terrestrial Environment Profiler) by the Helmholtz Association.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors, and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/ftox.2023.1221625/full#supplementary-material

References

Armitage, J. M., Sangion, A., Parmar, R., Looky, A. B., and Arnot, J. A. (2021). Update and evaluation of a high-throughput in vitro mass balance distribution model: IV-MBM EQP v2.0. Toxics 9 (11), 315. doi:10.3390/toxics9110315

PubMed Abstract | CrossRef Full Text | Google Scholar

Avdeef, A., Box, K. J., Comer, J. E. A., Hibbert, C., and Tam, K. Y. (1998). pH-metric logP 10 Determination of liposomal membrane-water partition coefficients of ionizable drugs. Pharm. Res. 15 (2), 209–215. doi:10.1023/a:1011954332221

PubMed Abstract | CrossRef Full Text | Google Scholar

Escher, B. I., Neale, P. A., and Villeneuve, D. L. (2018). The advantages of linear concentration-response curves for in vitro bioassays with environmental samples. Environ. Toxicol. Chem. 37 (9), 2273–2280. doi:10.1002/etc.4178

PubMed Abstract | CrossRef Full Text | Google Scholar

Groothuis, F. A., Heringa, M. B., Nicol, B., Hermens, J. L. M., Blaauboer, B. J., and Kramer, N. I. (2015). Dose metric considerations in in vitro assays to improve quantitative in vitro-in vivo dose extrapolations. Toxicology 332, 30–40. doi:10.1016/j.tox.2013.08.012

PubMed Abstract | CrossRef Full Text | Google Scholar

Gülden, M., Morchel, S., Tahan, S., and Seibert, H. (2002). Impact of protein binding on the availability and cytotoxic potency of organochlorine pesticides and chlorophenols in vitro. Toxicology 175 (1-3), 201–213. doi:10.1016/s0300-483x(02)00085-9

PubMed Abstract | CrossRef Full Text | Google Scholar

Henneberger, L., Huchthausen, J., König, M., Menge, A., Wojtysiak, N., and Escher, B. I. (2022). Experimental exposure assessment of designed chemical mixtures in cell-based in vitro bioassays. Front. Environ. Chem. 3, 1018162. doi:10.3389/fenvc.2022.1018162

CrossRef Full Text | Google Scholar

Henneberger, L., Mühlenbrink, M., Fischer, F. C., and Escher, B. I. (2019a). C18-coated solid-phase microextraction fibers for the quantification of partitioning of organic acids to proteins, lipids, and cells. Chem. Res. Toxicol. 32 (1), 168–178. doi:10.1021/acs.chemrestox.8b00249

PubMed Abstract | CrossRef Full Text | Google Scholar

Henneberger, L., Mühlenbrink, M., Heinrich, D. J., Teixeira, A., Nicol, B., and Escher, B. I. (2020). Experimental validation of mass balance models for in vitro cell-based bioassays. Environ. Sci. Technol. 54 (2), 1120–1127. doi:10.1021/acs.est.9b06144

PubMed Abstract | CrossRef Full Text | Google Scholar

Henneberger, L., Mühlenbrink, M., König, M., Schlichting, R., Fischer, F. C., and Escher, B. I. (2019b). Quantification of freely dissolved effect concentrations in in vitro cell-based bioassays. Archives Toxicol. 93 (8), 2295–2305. doi:10.1007/s00204-019-02498-3

CrossRef Full Text | Google Scholar

Heringa, M. B., Schreurs, R., van der Saag, P. T., van der Burg, B., and Hermens, J. L. M. (2003). Measurement of free concentration as a more intrinsic dose parameter in an in vitro assay for estrogenic activity. Chem. Res. Toxicol. 16 (12), 1662–1663.

Google Scholar

Huchthausen, J., Henneberger, L., Mälzer, S., Nicol, B., Sparham, C., and Escher, B. I. (2022). High-throughput assessment of the abiotic stability of test chemicals in in vitro bioassays. Chem. Res. Toxicol. 35 (5), 867–879. doi:10.1021/acs.chemrestox.2c00030

PubMed Abstract | CrossRef Full Text | Google Scholar

Huchthausen, J., Mühlenbrink, M., König, M., Escher, B. I., and Henneberger, L. (2020). Experimental exposure assessment of ionizable organic chemicals in in vitro cell-based bioassays. Chem. Res. Toxicol. 33 (7), 1845–1854. doi:10.1021/acs.chemrestox.0c00067

PubMed Abstract | CrossRef Full Text | Google Scholar

Inglese, J., and Auld, D. S. (2008). “High throughput screening (HTS) techniques: Applications in chemical biology,” in Wiley encyclopedia of chemical biology. Editor T. P. Begley, 1–15. doi:10.1002/9780470048672.wecb223

CrossRef Full Text | Google Scholar

Kolb, A. J., and Neumann, K. (1997). Beyond the 96-well microplate: Instruments and assay methods for the 384-well format. J. Biomol. Screen. 2 (2), 103–109. doi:10.1177/108705719700200209

CrossRef Full Text | Google Scholar

Neale, P. A., Altenburger, R., Ait-Aissa, S., Brion, F., Busch, W., de Aragao Umbuzeiro, G., et al. (2017). Development of a bioanalytical test battery for water quality monitoring: Fingerprinting identified micropollutants and their contribution to effects in surface water. Water Res. 123, 734–750. doi:10.1016/j.watres.2017.07.016

PubMed Abstract | CrossRef Full Text | Google Scholar

Niu, L., Henneberger, L., Huchthausen, J., Krauss, M., Ogefere, A., and Escher, B. I. (2022). pH-dependent partitioning of ionizable organic chemicals between the silicone polymer polydimethylsiloxane (PDMS) and water. ACS Environ. Au 2 (3), 253–262. doi:10.1021/acsenvironau.1c00056

PubMed Abstract | CrossRef Full Text | Google Scholar

Proença, S., Escher, B., Fischer, F., Fisher, C., Grégoire, S., Hewitt, N., et al. (2021). Effective exposure of chemicals in in vitro cell systems: A review of chemical distribution models. Toxicol. vitro 73, 105133. doi:10.1016/j.tiv.2021.105133

CrossRef Full Text | Google Scholar

Qin, W., Henneberger, L., Huchthausen, J., König, M., and Escher, B. I. (2023). Role of bioavailability and protein binding of four anionic perfluoroalkyl substances in cell-based bioassays for quantitative in vitro to in vivo extrapolations. Environ. Int. 173, 107857. doi:10.1016/j.envint.2023.107857

PubMed Abstract | CrossRef Full Text | Google Scholar

Rice, G., MacDonell, M., Hertzberg, R. C., Teuschler, L., Picel, K., Butler, J., et al. (2008). An approach for assessing human exposures to chemical mixtures in the environment. Toxicol. Appl. Pharmacol. 233 (1), 126–136. doi:10.1016/j.taap.2008.05.004

PubMed Abstract | CrossRef Full Text | Google Scholar

Ulrich, N., Endo, S., Brown, T. N., Watanabe, N., Bronner, G., Abraham, M. H., et al. (2017). UFZ-LSER database v 3.2.1. Available at: http://www.ufz.de/lserd (Accessed July 07, 2023).

Google Scholar

US National Research Council (2007). Toxicity testing in the 21st century. Washington, DC: The National Academies Press.

Google Scholar

Villeneuve, D. L., Coady, K., Escher, B. I., Mihaich, E., Murphy, C. A., Schlekat, T., et al. (2019). High-throughput screening and environmental risk assessment: State of the science and emerging applications. Environ. Toxicol. Chem. 38 (1), 12–26. doi:10.1002/etc.4315

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: solid-phase microextraction, bioassay, in vitro, high throughput, PPARγ

Citation: Huchthausen J, König M, Escher BI and Henneberger L (2023) Experimental exposure assessment for in vitro cell-based bioassays in 96- and 384-well plates. Front. Toxicol. 5:1221625. doi: 10.3389/ftox.2023.1221625

Received: 12 May 2023; Accepted: 06 July 2023;
Published: 25 July 2023.

Edited by:

Robert Landsiedel, BASF, Germany

Reviewed by:

Nynke Kramer, Wageningen University and Research, Netherlands
James Armitage, Université du Québec à Montréal, Canada

Copyright © 2023 Huchthausen, König, Escher and Henneberger. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Luise Henneberger, bHVpc2UuaGVubmViZXJnZXJAdWZ6LmRl

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.