Skip to main content

CASE REPORT article

Front. Surg., 11 July 2022
Sec. Otorhinolaryngology - Head and Neck Surgery

Mandibular Reconstruction With the Contralateral Vascularized Iliac Flap Using Individual Design: Iliac Crest Used to Reconstruct the Ramus and the Anterior Border of the Iliac Wing Used to Reconstruct the Inferior Border: A Case Report

\r\nGuangcai Xu,Guangcai Xu1,2Ju JiaJu Jia3Xuepeng XiongXuepeng Xiong3Liwei PengLiwei Peng2Lin-lin BuLin-lin Bu3Xiqian Wang
\r\nXiqian Wang2*
  • 1School of Stomatology, Henan University, Kaifeng, China
  • 2Department of Oral and Maxillofacial Surgery, Henan Provincial People's Hospital; Zhengzhou University People's Hospital; Henan University People's Hospital, Zhengzhou, China
  • 3Department of Oral Maxillofacial Head Neck Oncology, School and Hospital of Stomatology, Wuhan University, Wuhan, China

Mandible defects resulting from resection of benign or malignant lesions, trauma, or radionecrosis are commonly encountered in the oral and maxillofacial department. Vascularized bone flaps, in general, provide the best functional and aesthetic outcome. The iliac crest provides a large piece of curved cortico-cancellous bone, measuring 6–16 cm in length. It has a natural curvature that complements the curve of the lateral and sometimes anterior mandible and can be placed accordingly to fill defects. In the paper, we report a mandibular reconstruction with a vascularized iliac flap using individual virtual preoperative planning and 3D printing technology. We want to offer a new design idea for mandibular defect reconstruction.

Patient

A 24-year-old female was admitted to the Department of Oral & Maxillofacial-Head & Neck Oncology, Stomatology Hospital of Wuhan University. The patient found a bulge in the right mandible 10 months ago, and the bulge had been increasing gradually. After admission, clinical examination revealed a significant bulge of the right mandible (Figure 1A). Cone beam computerized tomography (CBCT) demonstrated that there was a bone mineral density reducing area of about 4.8 cm × 4.6 cm ×4.9 cm in the right mandible from 47 to the mandibular ramus region, and a buccolingual bulge was obvious (Figure 1B). The primary diagnosis was a right mandibular ameloblastoma, and the postoperative pathology also showed ameloblastoma.

FIGURE 1
www.frontiersin.org

Figure 1. Clinical examination revealing a significant bulge of the right mandibular: cone beam computerized tomography (CBCT) demonstrating that (A) there was a bone mineral density reducing area of nabout 4.8 cm × 4.6 cm × 4.9 cm in the right mandible from 47 to the mandibular ramus region and (B) Buccolingual bulge was obvious.

Preoperative Planning

The treatment aim was to resect the tumor radically and reconstruct the mandible immediately. Because the defect was less than 9 cm, we decided to reconstruct the defect with a vascularized iliac flap. The CBCT and the iliac bone CT data were obtained, and then, a virtual model by computer-aided design (CAD) was created. The osteotomy line and surgical cutting guide for the mandible were designed first (Figure 2A). The model of the defect region was used to look for the most matching region in the iliac bone model; we found that the most matching region was on the left iliac bone. The anterior superior iliac spine could be used to reconstruct the angle of the mandible, the iliac crest would be used to reconstruct the posterior border of the mandible ramus, and the anterior border of the iliac wing would be used to reconstruct the inferior border of mandible; the natural curvature of left iliac bone could complement the curve of the mandible perfectly and can be placed accordingly to fill the defect (Figure 2B). Then, we obtained the virtual iliac bone graft model (Figure 2C), which was used to design the bone graft cutting guide (Figure 2D), shaping guide (Figure 2E), and fixation guide (Figure 2F). All the models and guides were printed by a three-dimensional (3D) printer (Figures 3A–D).

FIGURE 2
www.frontiersin.org

Figure 2. Virtual model created by computer-aided design (CAD); the osteotomy line and surgical cutting guides for the mandible were designed first (A); the model of the defect region was used to look for the most matching region in the Iliac bone model, and we found that the most matching region was on the left iliac bone. The anterior superior iliac spine would be used to reconstruct the angle of the mandible, the iliac crest would be used to reconstruct the posterior border of the mandible ramus, and the anterior border of the iliac wing would be used to reconstruct the inferior border of the mandible; the natural curvature of left Iliac bone could complement the curve of the mandible perfectly and can be placed accordingly to fill the defect (B); then, the virtual iliac bone graft model was obtained (C), which was used to design the bone graft cutting guide (D), shaping guide (E), and fixation guide (F).

FIGURE 3
www.frontiersin.org

Figure 3. All models and guides were printed on a three-dimensional (3D) printer: original mandible model and cutting guide (A); iliac model and cutting guide (B); shaping guide (C); and reconstructed mandible model and fixation guide (D).

Operation

According to the preoperative planning and the surgical cutting guide, the right mandible from 47 to the condylar neck was resected (Figures 4A,B), and the vascularized iliac flap was harvested and prepared (Figures 4C–E). The prepared vascularized iliac flap was fixed to the mandible to reconstruct the mandible defect by a miniplate (Stryker Leibinger Gmbh&CO.CK. Botzinger StraBe 41,7911 Freiburg, Germany) according to the fixation guide. Additionally, the deep circumflex iliac artery (DICA) and the deep circumflex iliac vein (DICV) were anastomosed with the facial artery and external jugular vein, respectively (Figure 4F). The postoperative anterior view showed that the mandible is symmetrical (Figure 5A). Postoperative CBCT demonstrated that the grafted iliac bone matched the shape of the mandible satisfactorily (Figure 5B). The patient was satisfied with the function, facial appearance, and local scar recovery after the operation (Figure 6).

FIGURE 4
www.frontiersin.org

Figure 4. According to the surgical cutting guide, the right mandible from 47 to the condylar neck was resected (A,B); and the vascularized iliac flap was harvested and prepared (C–E). The prepared vascularized iliac flap was fixed to the mandible to reconstruct the mandible defect by a titanium plate according to the fixation guide, and the deep circumflex iliac artery (DICA) and the deep circumflex iliac vein (DICV) were anastomosed with facial artery and external jugular vein; the arrow shows that the vessel pedicle was in a line when the iliac bone flap was transferred to the mandible defect area (F).

FIGURE 5
www.frontiersin.org

Figure 5. Postoperative anterior view showing that the mandible is symmetrical for 3 months after operation (A); postoperative CBCT demonstrating that both the shape of the mandible and the height and width of the alveolar crest are satisfactory (B). L stands for the left side, R stands for the right side, both sides are ruler.

FIGURE 6
www.frontiersin.org

Figure 6. Lateral views showing that the facial incision healed well: (A–C) postoperative, 1 week, and 7 years after operation; postoperative function and facial appearance recovered well (D,E).

Discussion

With the development of society, patients’ desire for the result of reconstruction is stronger and higher, both aesthetically and functionality. A vascularized iliac flap is one of the best choices in mandibular reconstruction. The vascularized iliac flap is based on the deep circumflex iliac artery (DCIA), which arises from the lateral aspect of the external iliac artery. The diameter of the DCIA is in the range of 2–3 mm, and the length of the pedicle from the anterosuperior iliac spine to its junction at the external iliac artery is around 5–7 cm (1). The iliac crest provides a large piece of curved cortico-cancellous bone, measuring 6–16 cm in length. The iliac bone flap can provide enough bone height and thickness in mandible reconstruction and osseointegration dental implantation. The natural curvature of the iliac crest makes shaping the bone in anterior defects difficult (2). However, now, with the help of CAD virtual design, surgical cutting and fixation guides, and 3D printing technology, the shaping of bone grafts becomes much easier (35).

Generally, the iliac bone flap has a natural curvature that complements the curve of the lateral and sometimes anterior mandible and can be placed accordingly to fill defects. The homolateral iliac is always chosen as the donor site to reconstruct the mandibular defect, with the iliac crest being used to reconstruct the inferior border of the mandible, the anterior superior iliac spine being used to reconstruct the angle of the mandible, and the anterior border of the iliac wing being used to reconstruct the posterior border of the mandible ramus. In this case, however, we found that the most matching region was on the contralateral (left) iliac bone. The natural curvature of the left iliac bone could complement the curve of the mandible perfectly. In addition, this design could avoid the twist of the vessel pedicle and keep it in a line when the iliac bone flap was transferred to the mandible defect area (Figure 7).

FIGURE 7
www.frontiersin.org

Figure 7. Sketch map showing the relationship between the vessel pedicle and the iliac bone graft; the arrow shows that this design could avoid the twist of the vessel pedicle and keep it in a line when the iliac bone flap was transferred to the mandible defect area.

Data Availability Statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.

Ethics Statement

Ethical review and approval was not required for the study on human participants in accordance with the local legislation and institutional requirements. The patients/participants provided their written informed consent to participate in this study.

Written informed consent was obtained from the individual(s) for the publication of any potentially identifiable images or data included in this article.

Author Contributions

XW, LP, XX, and JJ: conceived the study. GX, XX, LB and JJ: collected the data. GX, LP and JJ: analyzed the data. XW, LP, and XX: provided guidance on data analysis. GX: wrote the paper. XW, LB and LP: revised the paper. All authors contributed to the article and approved the submitted version.

Funding

This study was supported by grants from the Henan Health Science and Technology Innovative Talent Project (02432).

Acknowledgments

The authors thank JOYE 3D Technology for its support in the preoperative virtual planing and model and guide manufacture.

Conflict of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's Note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Urken ML, Weinberg H, Buchbinder D, Moscoso JF, Lawson W, Catalano PJ, et al. Microvascular free flaps in head and neck reconstruction. Report of 200 cases and review of complications. Arch Otolaryngol Head Neck Surg. (1994) 120:633–40. doi: 10.1001/archotol.1994.01880300047007

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Chim H, Salgado CJ, Mardini S, Chen HC. Reconstruction of mandibular defects. Semin Plast Surg. (2010) 24(2):188–97. doi: 10.1055/s-0030-1255336

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Tsai M-J, Wu C-T. Study of mandible reconstruction using a fibula flap with application of additive manufacturing technology. Biomed Eng Online. (2014) 13:57. doi: 10.1186/1475-925X-13-57

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Tack P, Victor J. 3D-printing Techniques in a medical setting: a systematic literature review. Biomed Eng Online. (2016) 15:115. doi: 10.1186/s12938-016-0236-4

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Choi JW, Kim N. Clinical application of three-dimensional printing technology in craniofacial plastic surgery. Arch Plast Surg. (2015) 42(3):267–77. doi: 10.5999/aps.2015.42.3.267

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: mandibular, vascularized iliac flap, reconstruction, 3D printing, individual

Citation: Xu G, Jia J, Xiong X, Peng L, Bu L and Wang X (2022) Mandibular Reconstruction With the Contralateral Vascularized Iliac Flap Using Individual Design: Iliac Crest Used to Reconstruct the Ramus and the Anterior Border of the Iliac Wing Used to Reconstruct the Inferior Border: A Case Report. Front. Surg. 9:924241. doi: 10.3389/fsurg.2022.924241

Received: 20 April 2022; Accepted: 16 June 2022;
Published: 11 July 2022.

Edited by:

Sergio Olate, University of La Frontera, Chile

Reviewed by:

Essam Ahmed Al-Moraissi, Thamar University, Yemen
A.B. Zulkiflee, University Malaya Medical Centre, Malaysia
Silvano Ferrari, University Hospital of Parma, Italy

Copyright © 2022 Xu, Jia, Xiong, Peng, Bu and Wang. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Xiqian Wang d2FuZ3hpcWlhbjIwMDZAMTI2LmNvbQ==

Specialty section: This article was submitted to Otorhinolaryngology – Head and Neck Surgery, a section of the journal Frontiers in Surgery

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.