Skip to main content

ORIGINAL RESEARCH article

Front. Sports Act. Living, 17 April 2023
Sec. Biomechanics and Control of Human Movement
This article is part of the Research Topic Human Movement and Motor Control in the Natural Environment View all 18 articles

Quantifying and correcting for speed and stride frequency effects on running mechanics in fatiguing outdoor running

  • 1Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, Enschede, Netherlands
  • 2Department of Rehabilitation Technology, Roessingh Research and Development, Enschede, Netherlands

Measuring impact-related quantities in running is of interest to improve the running technique. Many quantities are typically measured in a controlled laboratory setting, even though most runners run in uncontrolled outdoor environments. While monitoring running mechanics in an uncontrolled environment, a decrease in speed or stride frequency can mask fatigue-related changes in running mechanics. Hence, this study aimed to quantify and correct the subject-specific effects of running speed and stride frequency on changes in impact-related running mechanics during a fatiguing outdoor run. Seven runners ran a competitive marathon while peak tibial acceleration and knee angles were measured with inertial measurement units. Running speed was measured through sports watches. Median values over segments of 25 strides throughout the marathon were computed and used to create subject-specific multiple linear regression models. These models predicted peak tibial acceleration, knee angles at initial contact, and maximum stance phase knee flexion based on running speed and stride frequency. Data were corrected for individual speed and stride frequency effects during the marathon. The speed and stride frequency corrected and uncorrected data were divided into ten stages to investigate the effect of marathon stage on mechanical quantities. This study showed that running speed and stride frequency explained, on average, 20%–30% of the variance in peak tibial acceleration, knee angles at initial contact, and maximum stance phase knee angles while running in an uncontrolled setting. Regression coefficients for speed and stride frequency varied strongly between subjects. Speed and stride frequency corrected peak tibial acceleration, and maximum stance phase knee flexion increased throughout the marathon. At the same time, uncorrected maximum stance phase knee angles showed no significant differences between marathon stages due to a decrease in running speed. Hence, subject-specific effects of changes in speed and stride frequency influence the interpretation of running mechanics and are relevant when monitoring, or comparing the gait pattern between runs in uncontrolled environments.

Highlights

• Effects of changes in speed and stride frequency on mechanics are subject-specific

• Speed and stride frequency explain 20%–30% of the variance in PTA and knee angles

• Changes in speed and stride frequency masked fatigue-related changes in mechanics

• Correct mechanics for changes in speed and stride frequency in outdoor running

1. Introduction

Motion analysis in running provides objective information about running technique. This information can be used to improve running performance (1, 2), monitor effects of fatigue on the gait pattern (3, 4), and possibly reduce injury risk through real-time feedback on mechanical quantities (57). Feedback is often provided on peak tibial acceleration (PTA) since this quantity is easy to measure and provides information about a combined effect of impact forces and running technique on the acceleration of the tibia (8). However, PTA is not directly linked to forces in the body since PTA is unable to represent the contribution of muscle contractions (9, 10). Monitoring of knee angles is of interest due to their role in shock attenuation during running (11) and their tendency to change with running-induced fatigue (9, 10, 12).

Traditionally, running mechanics were measured in a gait laboratory. A laboratory setting allows researchers to control or minimize influences on the gait pattern from, for instance, running speed, inclination, running surface, and the weather. Simultaneously, a laboratory setting is restricted to an artificial environment that is not sport-specific. Multiple mechanical quantities concerning peak accelerations and shock attenuation showed important differences between overground and treadmill running (1316). Hence, running mechanics should be analyzed in a representative environment since findings from laboratory-based treadmill studies cannot easily be generalized to overground running (14, 17, 18).

One essential difference between treadmill and outdoor running is the ability to adapt running speed. Most runners lower their speed after prolonged running due to fatigue (19, 20). The influence of running speed and stride frequency on mechanical variables has extensively been studied in controlled environments and typically on a treadmill. PTA increases with an increase in running speed (8) or a decrease in stride frequency (21). PTA showed a strong significant linear regression with speed in treadmill running (22, 23). Individual variances in these relationships were large, highlighting the need for subject-specific analysis (22, 24). Additionally, maximum stance phase knee flexion increased with an increase in speed or a decrease in stride frequency (25, 26). No speed effect on knee flexion angles at initial contact was found over a small range of running speeds in recreational runners (26). Hence, running speed and stride frequency influence PTA and knee joint angles in running which makes it hard to compare quantities both within and between runs when speed and stride frequencies are not consistent. Two previous studies corrected mechanical quantities during running in an uncontrolled setting for speed by computing individual ratios (i.e., dividing by speed) (19, 20). This correction assumes that the relationship between speed and quantities of interest crosses the origin (i.e., quantity of interest is zero when the speed is zero) and is linear over the full range of running speeds for all subjects. Such a relationship assumes that an increase in speed of 1 km/h during walking and running will result in the same increase in a quantity of interest. However, in the case of PTA, the regression equation between speed and PTA differs between foot strike patterns (20), between subjects (24) and the intercepts of group-based analyses do not appear to cross the origin (20). Thus, individual ratios likely oversimplify the relationship between speed and quantities of interest.

Inertial measurement units (IMUs) can measure running mechanics in a sport-specific setting and open up new possibilities for real-time feedback on running technique in a representative environment (18). Feedback on PTA values is often used to improve running technique by providing warnings for high PTA values, both in commercial devices and in research (2731). Additionally, algorithm development allows the estimation of knee angles based on a minimal sensor set (32). Feedback on running technique is often based on an arbitrary fixed threshold independent of running speed and stride frequency which can mask fatigue-related changes in running biomechanics. Without correcting for the effects of speed and stride frequency, the origin of changes is unclear, preventing appropriate interpretation and feedback on running biomechanics. Hence, this study aims to quantify and correct for the subject-specific effect of running speed and stride frequency on changes in impact-related running mechanics during a fatiguing outdoor run.

A marathon was used as an uncontrolled setting to ensure that a wide range of external influences (e.g., fatigue, different surfaces, other runners) found in typical uncontrolled outdoor running were incorporated to improve the ecological validity of relationships. We hypothesized that:

1. Running speed and stride frequency decrease toward the end of the marathon

2. The influence of running speed and stride frequency on PTA, knee angles at initial contact, and maximum stance phase knee flexion angles differs between subjects

3. Correcting PTA and knee angles for subject-specific changes in speed and stride frequency results in significant changes during the marathon which are not found in uncorrected values

2. Methods

2.1. Participants

Nine healthy recreational runners participated in this study. Technical errors resulted in missing data for two subjects. Therefore, data from three females and four males were included (mean (standard deviation); age: 36 (11) years, height: 181 (5) cm, mass: 74 (8) kg, running experience: 7 (4) years). All subjects gave written informed consent before participating in this study. The Ethics Committee Computer and Information Science of the University of Twente approved the study protocol.

2.2. Measurement systems

Subjects were equipped with eight IMUs (sampling frequency: 240 Hz, dimensions: 36 × 25 × 10 mm, weight: 16 g, MVN Link, Xsens Technologies, Enschede, The Netherlands). IMUs were placed on the sternum, back of the pelvis, and bilaterally on the midportion of the lateral upper leg, proximally on the tibia, and on the midfoot. Hair on the skin was shaved to improve IMU attachment before IMUs were fixed to the skin with double-sided tape and covered with additional tape. IMUs on the midfoot were placed under the tongue of the shoes. Wires between IMUs were loosely taped to the skin to prevent entanglement, see Figure 1. IMUs were connected with a bodypack and battery pack. The bodypack delivered power from the battery pack to the IMUs and synchronized and stored data from the IMUs on internal memory. The bodypack and battery pack weighed 220 grams (33) and were placed in a neoprene storage belt around the waist of the runners. Subjects used their personal sports watches with a global navigation satellite system (GNSS), measuring coordinates with different sampling frequencies of on average 0.7 (0.4 Hz).

FIGURE 1
www.frontiersin.org

Figure 1. One of the runners a few meters before the finish line. The bodypack and battery pack are placed in the pink belt. White tape is visible, which covers the sensors and fixates sensor wires.

2.3. Measurement protocol

Measurements were performed during the Enschede marathon (42.195 km) in the Netherlands on a typical Dutch spring day with temperatures around 10°C. The course was relatively flat, with about 42 meters of elevation and was performed in relatively open space (i.e., no woods) on the road. The track consisted of two laps of which about 60% of the course was identical between laps. Before the marathon, multiple anthropometric values were measured (body height, hip height, hip width, knee height, ankle height, and shoe length). Sensor-to-segment calibration was performed according to the manufacturer's recommendations (34). Subjects were instructed to run their marathon as planned and not to worry about the equipment.

2.4. Data analysis

The data presented in this study are openly available on figshare (https://doi.org/10.6084/m9.figshare.22331686.v1).

2.4.1. Data extraction and computing speed

Sensor data was extracted from the internal memory of the bodypack. Sensor acceleration, angular velocity, and magnetometer data were used to estimate sensor orientations in the software package Xsens MVN Analyze (version 2019.2.1). A scaled biomechanical model was created based on anthropometric measurements, raw sensor data (accelerations and angular velocities), and estimated sensor orientations. Knee flexion angles and pelvis IMU velocity were obtained from this scaled biomechanical model (34). Latitude and longitude coordinates were extracted from the GNSS data. Missing latitude-longitude coordinates were linearly interpolated before speed was computed as the distance between two latitude-longitude coordinates based on the Haversine formula (35). Speeds above 20 km/h were deemed extremely unlikely and replaced with spline interpolation. Speed was then resampled to 240 Hz to match the sampling frequency of the IMUs.

2.4.2. Temporal synchronization

GNSS and IMU data were temporally aligned based on GNSS speed and speed of the pelvis IMU. Pelvis IMU speed was computed as the resultant pelvis IMU velocity obtained from the scaled biomechanical model. GNSS and IMU data were then synchronized by cross-correlating GNSS speed with pelvis IMU speed. Temporal alignment between both systems was visually checked at the start and end of the marathon to ensure that possible differences in internal clocks would not influence temporal alignment. Visual misalignment was present in data of one subject, for which IMU data was resampled based on cross-correlation of the first and last 20% of the data points separately.

2.4.3. Removing walking parts and segmentation

Some participants walked for short periods during the marathon to drink something or due to fatigue. PTA is higher for running than for walking (36). Walking parts were detected and removed based on a minimum of two adjacent outliers in PTA of the right leg. In this case, an outlier was defined as a PTA value of more than four scaled median absolute deviations below the median over the complete marathon. The median absolute deviation is computed as the median of absolute deviations from the median value (37). The median absolute deviation is then scaled by multiplying by 1.48 to approximate the standard deviation as typically reported in literature (38). Additionally, ten strides before and after a walking part were removed to omit the effect of slowing down and increasing speed. After removing the walking parts, data were segmented into time-normalized gait cycles starting with initial contact based on right foot accelerations (39).

2.4.4. Extracting quantities of interest and removing outliers

Quantities of interest were computed for the right legs from all subjects. PTA was defined as the positive acceleration peak in the axial direction of the tibia in a sensor-fixed coordinate system during the first 33% of the gait cycle. Accelerations in the axial direction compared to the resultant acceleration were chosen to better represent the main direction of impact forces in the body. Knee flexion angles were defined as 0° when the leg was fully extended, and flexion resulted in positive values. The knee angle at initial contact was extracted from the first sample of the time-normalized gait cycle. Maximum stance phase knee flexion was defined as the maximum knee angle during the first 33% of the gait cycle. Stride frequency (strides/minute) was based on the time between two right initial contacts. Speed was averaged over the complete gait cycle. The average foot strike angle (i.e., angle between the foot and horizontal in the sagittal plane at initial contact) over the complete marathon was computed to determine the foot strike pattern of subjects (40). Outliers in quantities of interest were defined as values deviating more than four scaled median absolute deviations from the moving median over a window of 500 strides. A relatively large deviation from the median value was chosen to classify outliers to prevent removal of a considerable amount of data and over-smoothing the data. All strides with an outlier in any of the quantities of interest were removed from further analyses.

Median values over segments of 25 strides were computed, and outliers were removed (>4 scaled median absolute deviation from moving median over a window of 500 segments) to improve data stability and reduce the amount of data (41). The marathon was divided into ten stages to investigate the effect of marathon stage; each stage was roughly equal to 4 km of running data. Mean values for each stage of the marathon were computed from the earlier defined median values, see Figure 2.

FIGURE 2
www.frontiersin.org

Figure 2. Data extraction shown for peak tibial acceleration (PTA). The top figure shows the tibial acceleration of a representative runner (runner 7) during the full marathon. Walking parts are labeled red and removed from further analysis. The middle figure shows a snapshot of the tibial acceleration signal in which PTAs are shown with green dots. Vertical grey lines show segments of 25 strides from which the median PTA is computed and shown as a pink dot. The bottom figure shows all median PTA values during the marathon. The full marathon duration is divided into ten stages for group-based statistical analyses.

2.5. Statistical analysis

Group-based one-way repeated measures ANOVAs were performed to test whether running speed, stride frequency, PTA, knee angles at initial contact, and maximum stance phase knee flexion changed over the different stages of the marathon. The ANOVAs had ten levels (stages of the marathon), and the mean values for each subject for all ten stages were used as input. When a significant effect of marathon stage on one of the quantities of interest was found, post hoc tests were used to test which marathon stages differed from each other.

Subject-specific multiple linear regression models were created to test if running speed and stride frequency could predict PTA, knee angles at initial contact, and maximum stance phase knee flexion angles. Median values for all 25 stride segments were used as input for the regression models, and no distinction for marathon stage was made. Intercepts and coefficients from the subject-specific regression equations were used to correct PTA and knee angles for the subject-specific effect of changes in speed and stride frequency. PTA and knee angles were corrected for individual changes in speed by subtracting the individual coefficients for speed (i.e., output of the multiple linear regression model) multiplied with the deviation from the individual mean speed for all segments of 25 strides during the marathon. Corrections for individual changes in stride frequency were performed similarly. Effectively, this method recomputes the quantities of interest as if the speed and stride frequency were equal to the average speed and stride frequency during the whole marathon.

Group-based one-way repeated measures ANOVAs (10-levels) were repeated to test whether speed and stride frequency corrected PTA, knee angles at initial contact, and maximum stance phase knee flexion changed over the different stages of the marathon.

An alpha level of 0.05 was used to determine statistical significance. When applicable, Holm-Bonferroni corrections were applied for all possible 45 post hoc pairwise comparisons. Correlations were interpreted as very strong r = (0.90, 1.00), strong for r = (0.70, 0.89), moderate for r = (0.40, 0.69), weak for r = (0.20, 0.39) and very weak for r = (0.00, 0.19) (42). Statistical analyses were performed in JASP (version 0.16.3).

3. Results

Subjects finished the marathon in 3 h and 55 min (30 min), with an average speed of 11.0 (1.5) km/h and an average stride frequency of 85.6 (2.9) strides/minute. Walking parts resulted in the removal of 2.7 (2.1)% of all data points. An average of 19,383 (2,073) gait cycles were measured per runner, of which 8.8 (2.4)% was removed due to outliers. Runners 1 and 5 were classified as non-rearfoot strikers based on a foot contact angle smaller than 8° (40).

3.1. Speed and stride frequency

There was a statistically significant effect of marathon stage on speed on a group level, F(9,54) = 5.766, p < 0.001, see Figure 3. Running speed decreased from 11.5 (1.8) km/h to 10.3 (1.4) km/h between the first and last stages of the marathon. Post-hoc analyses showed that speed during the last two stages was lower than in the first four stages of the marathon. No significant effect of marathon stage on stride frequency was found on a group-level, F(9,54) = 0.725, p = 0.684. Speed and stride frequency were weakly correlated on a group level, r = 0.21 (0.18).

FIGURE 3
www.frontiersin.org

Figure 3. Mean speed and stride frequency for every runner during all marathon stages. The solid red lines show the group means. A significant effect of marathon stage on speed was found. Significant results from post hoc analyses are shown by an asterisk at the top of the figure.

3.2. Peak tibial acceleration

On a group level, PTA had a moderate positive correlation with speed [r = 0.40 (0.24)] and no correlation was present with stride frequency due to large variability between subjects [r = −0.09 (0.20)], see Table 1. Subject-specific multiple linear regression equations to predict PTA based on speed and stride frequency were significant for all subjects and explained 26 (18)% of the variance in PTA, see Figure 4. Speed was a significant predictor of PTA for all runners while stride frequency was a significant predictor for all but one runner. On a group level, there was a statistically significant effect of marathon stage on PTA both for uncorrected [F(9,54) = 2.786, p = 0.009] and speed and stride frequency corrected values [F(9,54) = 2.316, p = 0.028]. However, post hoc analyses only showed significant differences in PTA between marathon stages after correcting for speed and stride frequency, see Figure 5. Post hoc analysis showed that PTA corrected for speed and stride frequency was higher in the third [77.5 (17.3)] compared to the first stage of the marathon [71.0 (17.5)].

FIGURE 4
www.frontiersin.org

Figure 4. Scatterplot of individual peak tibial acceleration and knee angle values as a function of speed. Each dot represents the median value over a segment of 25 strides during the marathon. Subject-specific linear regressions are shown as solid lines.

FIGURE 5
www.frontiersin.org

Figure 5. Individual mean peak tibial accelerations during all marathon stages. Dotted lines show uncorrected PTA values (i.e., as measured during the marathon). Solid lines represent speed and stride frequency corrected PTA values. Grey lines show the group means. Significant effects of running duration are shown with an asterisk and black lines. Solid black lines represent significant differences in corrected PTA values.

TABLE 1
www.frontiersin.org

Table 1. Left side of table: individual correlations of peak tibial acceleration (PTA) with speed and stride frequency (SF). Right side of table: Individual regression equations to predict PTA based on speed and stride frequency together with the adjusted R-squared value (i.e., explained variance of regression equation). r, Pearson's correlation coefficient; SD, standard deviation; ns, non-significant finding; NRF, non-rearfoot striking subject.

3.3. Knee angle at initial contact

On a group level, knee angles at initial contact showed a weak negative correlation with speed [r = −0.24 (0.30)] and no correlation was present with stride frequency due to large variability between runners [r = −0.03 (0.28)], see Table 2. Subject-specific multiple linear regression equations to predict knee angles at initial contact based on speed and stride frequency were significant for all subjects and explained 20 (10)% of the variance in knee angles at initial contact, see Figure 6. Speed was a significant predictor of knee angles at initial contact for all runners while stride frequency was a significant predictor for all but two runners. On a group level, there was a statistically significant effect of marathon stage on both corrected [F(9,54) = 5.136, p < 0.001] and uncorrected knee angles at initial contact [F(9,54) = 7.227, p < 0.001]. Post hoc analyses showed that knee angles at initial contact during later stages of the marathon were significantly higher than during the first stages of the marathon, see Figure 6.

FIGURE 6
www.frontiersin.org

Figure 6. Individual mean knee angles during all marathon stages. The left figure shows knee angles at initial contact, while the right figure shows maximum stance phase knee flexion angles. Dotted lines show uncorrected knee angles (i.e., as measured during the marathon). Solid lines represent speed and stride frequency corrected knee angles. Dotted black lines represent significant differences in uncorrected knee angles while solid black lines represent significant differences in knee angles corrected for the effect of changes in speed and stride frequency. Grey lines show the group means. Significant effects of marathon stage are shown with an asterisk and black lines.

TABLE 2
www.frontiersin.org

Table 2. Left side of table: individual correlations of knee angles at initial contact (IC) with speed and stride frequency (SF). Right side of table: Individual regression equations to predict knee angles at IC based on speed and stride frequency together with the adjusted R-squared value (i.e., explained variance of regression equation). r, Pearson’s correlation coefficient; SD, standard deviation; ns, non-significant finding; NRF, non-rearfoot striking subject.

3.4. Maximum stance phase knee angles

On a group level, maximum stance phase knee angles had a weak positive correlation with speed [r = 0.32 (0.27)] and a weak negative correlation with stride frequency [r = −0.21 (0.28)], see Table 3. Subject-specific multiple linear regression equations to predict maximum stance phase knee angles based on speed and stride frequency were significant for all subjects and explained 30 (20)% of the variance in maximum stance phase knee angles, see Figure 6. Speed was a significant predictor for maximum stance phase knee angles for all runners while stride frequency was a significant predictor for all but one runner. On a group level, marathon stage had no statistically significant effect on maximum stance phase knee flexion [F(9,54) = 1.770, p = 0.096]. After correcting knee angles for subject-specific effects of speed and stride frequency, a significant effect of marathon stage on maximum stance phase knee flexion was found [F(9,54) = 2.294, p = 0.029]. Post hoc analyses showed that the maximum stance knee flexion corrected for speed and stride frequency was significantly higher in the third [43.4 (4.9)] compared to the first stage of the marathon [41.8 (4.0)], see Figure 6.

TABLE 3
www.frontiersin.org

Table 3. Left side of table: individual correlations of maximum stance phase knee angles with speed and stride frequency (SF). Right side of table: Individual regression equations to predict maximum stance phase knee angles based on speed and stride frequency together with the adjusted Rsquared value (i.e., explained variance of regression equation). r, Pearson’s correlation coefficient; SD, standard deviation; ns, non-significant finding; NRF, non-rearfoot striking subject.

4. Discussion

This research aimed to quantify and correct for the subject-specific effect of changes in running speed and stride frequency on impact-related running mechanics during a fatiguing outdoor run. In line with our first hypothesis, speed decreased throughout the marathon, however, no effect of marathon stage on stride frequency was found. Running speed and stride frequency explained, on average 20%–30% of the variance in PTA, knee angles at initial contact, and maximum stance phase knee flexion while running in an uncontrolled setting. Regression coefficients for speed and stride frequency varied strongly between subjects, supporting our second hypothesis. Our third hypothesis was not supported for PTA and knee angles at initial contact, but was supported by a significant change in maximum stance phase knee flexion corrected for changes in speed and stride frequency, while uncorrected values showed no significant change during the marathon.

4.1. Speed and stride frequency

Running speed significantly decreased during the marathon. A decrease in speed during a marathon is typically found (19, 20, 43, 44) and is likely caused by fatigue, although race strategy can also play a role. Stride frequency did not show a significant effect of marathon stage and was weakly correlated with speed, indicating that, similar to previous studies, the speed reduction is generally caused by a decrease in stride length instead of stride frequency (19, 45). The significance of predictors, regression equations, and explained variances differed between subjects. Differences might be caused by differences in body weight, ankle angle at initial contact (46), foot strike pattern (20), individual differences in adaptations to speed by increasing step length vs. stride frequency, differences in the tolerance to effects of fatigue and differences in the capacity to sustain a stable gait pattern over a range of speeds. Even though stride frequency did not change on a group level, adding stride frequency to the regression models resulted in significantly better predictions for almost all runners, emphasizing the benefits of subject-specific analysis vs. group-based analysis.

4.2. Peak tibial acceleration

Average group-based PTA values (81.2 ± 8.4 m/s2) showed a significant main effect of marathon stage, although post hoc analyses showed no differences between marathon stages for uncorrected values. PTA values were within the range found in literature (49.1–116.7 m/s2) (8, 20, 47). The correlations between PTA and speed [r = 0.40 (0.24)] during a marathon were similar to the correlations between resultant PTA and speed in controlled settings (r = 0.42) (24). Subject-specific multiple linear regressions showed that, on average, PTA increased with 3.6 m/s2 for every 1 km/h increase in speed, although subject-specific coefficients ranged from 1.5 to 7.8 m/s2. The speed coefficient of PTA was between 4.1 and 6.7 m/s2 in controlled settings (23, 48). The speed coefficient to predict PTA in our study was generally lower than in laboratory-based studies, possibly due to the inclusion of stride frequency or external influences like fatigue. Foot strike pattern has been shown to influence the speed coefficient of PTA during a marathon. Rearfoot striking runners showed higher speed coefficients (12.8 m/s2) than midfoot striking runners (7.0 m/s2), while no significant speed coefficient was found for forefoot striking runners (20). In our study, the two non-rearfoot striking runners (subjects 1 and 5) had amongst the highest speed coefficients, which is possibly an effect of group- vs. subject-based analysis. The regression equation explained, on average, 26 (18)% of the variance in PTA. Although relatively low, it is higher than the 19% of explained variance in resultant PTA found in laboratory-based studies (24). To accurately predict PTA in outdoor environments, more variables are needed in the multiple linear regression equation (e.g., knee angle at initial contact), but for the scope of this paper, we were solely interested in the explained variance by speed and stride frequency. After correcting PTA for the subject-specific effects of speed and stride frequency, post hoc tests showed a significant increase in PTA between the first and third stages of the marathon. While this increase in PTA occurred very early on in the marathon, it is not uncommon for peak accelerations to increase during early stages of a fatiguing protocol (4951). An increase in PTA corrected for changes in speed and stride frequency could indicate a decrease in the runner's capacity to attenuate shocks. Alternatively, the effective mass (i.e., the portion of body mass that is decelerated upon ground contact) can decrease with an increased rearfoot or knee flexion angle and increase with a more vertical lower leg at initial contact (46, 52). A smaller effective mass is easier to accelerate, which results in higher leg accelerations when similar ground reaction forces are applied. High PTA values have long been thought to be an indicator of injury risk based on retrospective studies showing that PTA was higher in previously injured compared to uninjured runners (53, 54). The repetitiveness of high forces on tissues inside the body are thought to be related to the development of running injuries (55). However, PTA is uncapable to represent tibial bone loading since it does not represent forces caused by muscle contractions in the body (9, 10). Hence, high PTA values are no indicator of injury risk on their own but do provide information about a combined effect of impact forces and running technique on the body during running.

4.3. Knee angles

Average knee angles at initial contact (16.1 (2.5)°) and maximum stance phase knee angles (42.9 (5.1)°) were within the range reported in literature, respectively 9.5°–19.5° and 31.0°–56.2° (4, 26, 52, 56, 57). Knee angles at initial contact showed a negative weak and very weak correlation with speed and stride frequency, indicating more knee extension with higher speeds and stride frequencies. Previously, the knee flexion angle at initial contact remained similar (26) or increased with speed (58), although the range of speeds included was drastically higher than those found during the marathon. A decrease in knee angle at initial contact with an increase in speed might be a strategy to increase stride length by increasing leg extension. Knee angles at initial contact corrected for subject-specific effects of changes in speed and stride frequency showed a similar increasing pattern during the marathon compared to uncorrected values. Knee angles at initial contact have been found to increase with fatigue in controlled settings (12, 52, 57), possibly to decrease vertical ground reaction forces (46) at a higher metabolic cost (59). Hence, the increase in knee angles at initial contact during a marathon is not solely an effect of changes in speed and stride frequency but is likely a result of fatigue.

Maximum stance phase knee angles had a weak positive correlation with speed and a weak negative correlation with stride frequency, indicating that the stance phase shortens at higher stride frequencies, resulting in less knee flexion during stance (25). An increase in knee flexion with an increase in speed has been shown previously (26) and might be caused by higher forces on the body that need to be absorbed at higher speeds. The average increase in maximum stance phase knee flexion of 0.8° for every 1 km/h increase in speed is similar to previous findings in controlled settings (0.7°) (26). Maximum stance phase knee flexion angles corrected for changes in speed and stride frequency reveal a significant increase between the first and third stages of the marathon that is not present in uncorrected values. Although a statistically significant difference was found after correcting maximum stance phase knee angles for subject-specific effects of speed and stride frequency, the sample size was small with large variability and the clinical relevance of this finding might be limited. Further research should investigate the effect of speed and stride frequency on knee angles in more runners to investigate the clinical relevance and repeatability of this finding. However, an increase in maximal stance knee flexion could indicate an increase in stride length (60), knee extensor strength loss, or a reduced tolerance to imposed stretch loads with fatigue (44, 61). Despite relatively small explained variances of regression equations for knee angles, subject-specific corrections for changes in speed and stride frequency on knee angles significantly influenced the interpretation of mechanical changes during a marathon.

4.4. Fatigue

Subjects likely experienced high levels of fatigue toward the end of the marathon. Running-induced fatigue typically increases PTA (12), knee flexion at initial contact (12) and tends to increase maximal stance phase knee flexion (52, 57, 62). Both speed and fatigue have been positively associated with PTA and maximum stance phase knee angles (8, 12, 26, 52). Fatigue might have caused lower speed coefficients for PTA and maximum stance phase knee angles than expected without the influence of fatigue. Since subjects generally ran slower at the end of the marathon, PTA and maximum knee angles possibly decreased less with a decrease in speed towards the end of the marathon due to fatigue. Therefore, the influence of speed and stride frequency on running mechanics in an uncontrolled environment might be larger than shown in this study. To omit the effect of fatigue, we could have taken data from the start of the marathon, defined linear regression equations from data in an unfatigued state, and applied a correction to the remainder of the data, similar to Clermont et al. (63). However, most runners will experience some level of fatigue during their runs, making relationships solely based on unfatigued data invalid. Hence, we deliberately included data from an unfatigued to a fully fatigued state to create subject-specific relationships with better ecological validity.

4.5. Limitations

Collecting data in an uncontrolled environment is both a benefit and a shortcoming of this study. The benefit is that runners were measured in the actual environment where they typically run without any constrictions that a laboratory setting or a treadmill would impose on their gait pattern. However, we investigated the effects of speed and stride frequency on multiple mechanical quantities. At the same time, many other external influences could have played a role, such as running surface, fatigue, other runners, or distractions. The explained variance of quantities of interest can be improved by incorporating additional variables into the regression equation. However, for the scope of this paper, we were only interested in how much of the variance in included quantities could be explained by changes in speed and stride frequency.

The limited number of subjects in this study might have led to an underpowered group-based analyses to compare the effect of marathon stage on both corrected and uncorrected PTA and knee angle values. However, the large variability between runners, as demonstrated in the running speed, and speed coefficients for PTA and knee angles, emphasized the need for subject-specific analysis and corrections of the gait pattern, as demonstrated in this research.

Measurement equipment could have influenced the findings of this study in multiple ways. Different sports watches were used which could result in varying sampling frequencies and accuracies of the measured running speed. A lower sampling frequency could lead to allocation of varying PTA or knee angle values to a single running speed or stride frequency, therefore influencing the speed and stride frequency coefficients. Additionally, a low sampling frequency or GNSS signal loss could lead to high measured running velocities (>20 km/h). These high velocities were deemed unlikely and replaced by spline interpolation, potentially underestimating the actual running velocity. However, by computing quantities over segments of 25 strides, the running speed during each segment was computed based on multiple measurements, decreasing the influence of a low running speed sampling frequency and varying accuracies of sports watches on the outcomes of this study. For future studies we would recommend to compute running speed based on IMU signals.

Furthermore, PTA was measured with an IMU fixed to the skin. Skin-mounted IMUs are prone to soft-tissue artefacts as they can move with respect to the underlying bone, resulting in measurement errors (8). IMU displacement with respect to the body could have occurred due to sweating which would have influenced the sensor-to-segment calibration and output of the IMUs. However, IMUs seemed to be properly attached after the marathon and no sudden changes of a sensor becoming loose were found in the data.

4.6. Practical implications

This study showed that running speed and stride frequency have a subject-specific relationship with PTA, knee angles at initial contact, and maximum stance phase knee flexion. Correcting for these relationships influences the interpretation of changes in mechanical quantities while running in an uncontrolled environment and allows for comparisons of mechanical quantities between runs at different running speeds. Many wearable devices provide feedback on peak accelerations to improve the gait pattern (2931). Typically, feedback is provided on PTA values above a certain generic threshold. PTA values above this threshold which are caused by an increase in running speed or a decrease in stride frequency provide information about the absolute PTA value. The absolute PTA value can easily be lowered by changing running speed or stride frequency. In addition, speed and stride-frequency corrected PTA values provide information about relative PTA values. Speed and stride frequency corrected PTA values that are higher than expected at the current speed and stride frequency can warn runners for suboptimal changes in their gait pattern. Hence, changes in speed and stride frequency corrected PTA values provide information about a shift in the human body while performing a similar task (i.e., running at the same speed with the same stride frequency). A subject-specific model of the relationship between speed, stride frequency and quantities of interest based on multiple runs in different conditions would allow for comparisons of mechanical quantities between runs independent of running speed and stride frequency to better monitor progression of a runner. While this study demonstrated the effect of subject-specific corrections on PTA and knee angles, similar corrections can be made for other quantities of interest. For instance for biomechanical risk factors for overuse injuries like knee stiffness, peak hip adduction, ankle eversion or pelvic drop angles (7, 64, 65). Hence, we advise investigating and correcting for subject-specific regression equations for all quantities of interest when measuring, comparing and providing feedback on running mechanics in an uncontrolled environment.

Conclusions

In this study, we quantified and corrected for the subject-specific effect of changes in running speed and stride frequency on impact-related running mechanics during a fatiguing outdoor run. Subject-specific corrections through multiple linear regression equations revealed a significant effect of marathon stage on maximal stance phase knee flexion, which was previously masked by changes in speed and stride frequency. The effect of marathon stage on PTA and knee angles at initial contact changed after correcting for changes in speed and stride frequency. Hence, speed and stride frequency influence the interpretation of changes in mechanical quantities in a subject-specific manner when running in an uncontrolled environment. Subject-specific effects of speed and stride frequency on quantities of interest should be investigated and corrected when interpreting, or providing feedback on, running mechanics in an uncontrolled environment.

Data availability statement

The accompanying dataset for this study is publicly available. This data can be found here: https://doi.org/10.6084/m9.figshare.22331686.v1.

Ethics statement

The studies involving human participants were reviewed and approved by Ethics Committee Computer and Information Science of the University of Twente. The patients/participants provided their written informed consent to participate in this study. Written informed consent was obtained from the individual(s) for the publication of any potentially identifiable images or data included in this article.

Author contributions

JB, PV, and JR were involved with funding acquisition. MZ, JB, PV, and JR all contributed to the design of the study. MZ and JR organized and performed the measurements. MZ performed data analysis. MZ, JB, PV, and JR interpreted the findings. JB, PV, and JR supervised the project. MZ and JR wrote the first draft of the manuscript, after which the manuscript was critically reviewed, edited, and approved by all authors (MZ, JB, PV, and JR). All authors contributed to the article and approved the submitted version.

Funding

This study was supported by EFRO OP Oost (Grant number: 0784). The study sponsor had no involvement in the study design, data collection, analysis, interpretation, writing, or decision to submit the manuscript for publication.

Acknowledgments

The authors would like to thank the organization of the Enschede Marathon and the runners who participated in this study for their time and dedication to increase our knowledge about running.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Pizzuto F, De Oliveira CF, Soares TSA, Rago V, Silva G, Oliveira J. Relationship between running economy and kinematic parameters in long-distance runners. J Strength Cond Res. (2019) 33(7):1921–8. doi: 10.1519/JSC.0000000000003040

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Saunders PU, Pyne DB, Telford RD, Hawley JA. Factors affecting running economy in trained distance runners. Sports Med. (2004) 34(7):465–85. doi: 10.2165/00007256-200434070-00005

PubMed Abstract | CrossRef Full Text | Google Scholar

3. García-Pinillos F, Cartón-Llorente A, Jaén-Carrillo D, Delgado-Floody P, Carrasco-Alarcón V, Martínez C, et al. Does fatigue alter step characteristics and stiffness during running? Gait Posture. (2020) 76:259–63. doi: 10.1016/j.gaitpost.2019.12.018

CrossRef Full Text | Google Scholar

4. Maas E, De Bie J, Vanfleteren R, Hoogkamer W, Vanwanseele B. Novice runners show greater changes in kinematics with fatigue compared with competitive runners. Sports Biomech. (2018) 17(3):350–60. doi: 10.1080/14763141.2017.1347193

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Giraldo-Pedroza A, Chiu-Chun Lee W, Lam W, Coman R, Alici G. Effects of wearable devices with biofeedback on biomechanical performance of running—a systematic reveiw. Sensors (Switzerland). (2020) 20:6637. doi: 10.3390/s20226637

CrossRef Full Text | Google Scholar

6. Van Hooren B, Goudsmit J, Restrepo J, Vos S. Real-time feedback by wearables in running: current approaches, challenges and suggestions for improvements. J Sports Sci. (2020) 38(2):214–30. doi: 10.1080/02640414.2019.1690960

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Willwacher S, Kurz M, Robbin J, Thelen M, Hamill J, Kelly L, et al. Running-related biomechanical risk factors for overuse injuries in distance runners: a systematic review considering injury specificity and the potentials for future research. Sports Med. (2022) 52(8):1863–77. doi: 10.1007/s40279-022-01666-3

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Sheerin KR, Reid D, Besier TF. The measurement of tibial acceleration in runners—a review of the factors that can affect tibial acceleration during running and evidence-based guidelines for its use. Gait Posture. (2019) 67:12–24. doi: 10.1016/j.gaitpost.2018.09.017

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Zandbergen MA, Marotta L, Bulthuis R, Buurke JH, Veltink PH, Reenalda J. Effects of level running-induced fatigue on running kinematics: a systematic review and meta-analysis. Gait Posture. (2023) 99:60–75. doi: 10.1016/j.gaitpost.2022.09.089

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Zandbergen MA, ter Wengel XJ, van Middelaar RP, Buurke JH, Veltink PH, Reenalda J. Peak tibial acceleration should not be used as indicator of tibial bone loading during running. Sports Biomech. (2023):1–18. doi: 10.1080/14763141.2022.2164345

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Derrick TR. The effects of knee contact angle on impact forces and accelerations. Med Sci Sports Exercise. (2004) 36(5):832–7. doi: 10.1249/01.MSS.0000126779.65353.CB

CrossRef Full Text | Google Scholar

12. Apte S, Prigent G, Stöggl T, Martínez A, Snyder C, Gremeaux-Bader V, et al. Biomechanical response of the lower extremity to running-induced acute fatigue: a systematic review. Front Physiol. (2021) 12:1–16. doi: 10.3389/fphys.2021.646042

CrossRef Full Text | Google Scholar

13. García-Pérez JA, Pérez-Soriano P, Llana Belloch S, Lucas-Cuevas ÁG, Sánchez-Zuriaga D. Effects of treadmill running and fatigue on impact acceleration in distance running. Sports Biomech. (2014) 13(3):259–66. doi: 10.1080/14763141.2014.909527

CrossRef Full Text | Google Scholar

14. Lafferty L, Wawrzyniak J, Chambers M, Pagliarulo T, Berg A, Hawila N, et al. Clinical indoor running gait analysis may not approximate outdoor running gait based on novel drone technology. Sports Health. (2021) 14(5):710–6. doi: 10.1177/19417381211050931

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Milner CE, Hawkins JL, Aubol KG. Tibial acceleration during running is higher in field testing than indoor testing. Med Sci Sports Exercise. (2020) 52(6):1361–6. doi: 10.1249/MSS.0000000000002261

CrossRef Full Text | Google Scholar

16. Sinclair J, Richards J, Taylor PJ, Edmundson CJ, Brooks D, Hobbs SJ. Three-dimensional kinematic comparison of treadmill and overground running. Sports Biomech. (2013) 12(3):272–82. doi: 10.1080/14763141.2012.759614

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Benson LC, Clermont CA, Ferber R. New considerations for collecting biomechanical data using wearable sensors: the effect of different running environments. Front Bioeng Biotechnol. (2020) 8:1–8. doi: 10.3389/fbioe.2020.00086

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Benson LC, Räisänen AM, Clermont CA, Ferber R. Is this the real life, or is this just laboratory? A scoping review of IMU-based running gait analysis. Sensors. (2022) 22(5):1–38. doi: 10.3390/s22051722

CrossRef Full Text | Google Scholar

19. Chan-Roper M, Hunter I, Myrer JW, Eggett DL, Seeley MK. Kinematic changes during a marathon for fast and slow runners. J Sports Sci Med. (2012) 11(1):77–82. PMID: 24137065.24137065

PubMed Abstract | Google Scholar

20. Ruder M, Jamison ST, Tenforde A, Mulloy F, Davis IS. Relationship of foot strike pattern and landing impacts during a marathon. Med Sci Sports Exercise. (2019) 51(10):2073–9. doi: 10.1249/MSS.0000000000002032

CrossRef Full Text | Google Scholar

21. Busa MA, Lim J, Van Emmerik REA, Hamill J. Head and tibial acceleration as a function of stride frequency and visual feedback during running. PLoS ONE. (2016) 11(6):1–13. doi: 10.1371/journal.pone.0157297

CrossRef Full Text | Google Scholar

22. Clarke TE, Cooper LB, Clark DE, Hamill CL. The effect of increased running speed upon peak shank deceleration during ground contact. In: Winter DA, Norman RW, Wells RP, Hayes KC, Patla AE, editors. Biomechanics IX-B. Champaign, Ill.: Human Kinetics. p. 101–5. ISBN 087322 121 4.

Google Scholar

23. Mercer JA, Vance J, Hreljac A, Hamill J. Relationship between shock attenuation and stride length during running at different velocities. Eur J Appl Physiol. (2002) 87(4–5):403–8. doi: 10.1007/s00421-002-0646-9

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Sheerin KR, Besier TF, Reid D. The influence of running velocity on resultant peak tibial acceleration in runners. Sports Biomech. (2018):1–11. doi: 10.1080/14763141.2018.1546890

CrossRef Full Text | Google Scholar

25. Heiderscheit BC, Chumanov ES, Michalski MP, Wille CM, Ryan MB. Effects of step rate manipulation on joint mechanics during running. Med Sci Sports Exercise. (2011) 43(2):296–302. doi: 10.1249/MSS.0b013e3181ebedf4

CrossRef Full Text | Google Scholar

26. Orendurff MS, Kobayashi T, Tulchin-Francis K, Tullock AMH, Villarosa C, Chan C, et al. A little bit faster: lower extremity joint kinematics and kinetics as recreational runners achieve faster speeds. J Biomech. (2018) 71:167–75. doi: 10.1016/j.jbiomech.2018.02.010

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Crowell HP, Milnert CE, Hamill J, Davis IS. Reducing impact loading during running with the use of real-time visual feedback. J Orthop Sports Phys Ther. (2010) 40(4):206–13. doi: 10.2519/jospt.2010.3166

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Crowell HP, Davis IS. Gait retraining to reduce lower extremity loading in runners. Clin Biomech. (2011) 26(1):78–83. doi: 10.1016/j.clinbiomech.2010.09.003

CrossRef Full Text | Google Scholar

29. Moov now. (n.d.). https://welcome.moov.cc/.

30. Runscribe. (n.d.). https://runscribe.com/metrics/.

31. TgForce 3D. (n.d.). https://tgforce.com/about-tibial-shock/.

32. Wouda FJ, Giuberti M, Bellusci G, Maartens E, Reenalda J, van Beijnum BJF, et al. Estimation of vertical ground reaction forces and sagittal knee kinematics during running using three inertial sensors. Front Physiol. (2018) 9:1–14. doi: 10.3389/fphys.2018.00218

PubMed Abstract | CrossRef Full Text | Google Scholar

33. Schepers M, Giuberti M, Bellusci G. Xsens MVN: Consistent Tracking of Human Motion Using Inertial Sensing. (2018). p. 1–8. doi: doi: 10.13140/RG.2.2.22099.07205

34. Xsens Technologies B.V. MVN User Manual. MVN Manual, April, 162. (2021). https://www.cleancss.com/user-manuals/QIL/MTW2-3A7G6

35. Chopde NR, Nichat MK. Landmark based shortest path detection by using A* and haversine formula. Int J Innovative Res Comput Commun Eng. (2013) 1(2):298–302. ISNN: ISSN (Online): 2320-9801.

Google Scholar

36. Lafortune MA. Three-dimensional acceleration of the tibia during walking and running. J Biomech. (1991) 24(10):877–86. doi: 10.1016/0021-9290(91)90166-K

PubMed Abstract | CrossRef Full Text | Google Scholar

37. Leys C, Ley C, Klein O, Bernard P, Licata L. Detecting outliers: do not use standard deviation around the mean, use absolute deviation around the median. J Exp Soc Psychol. (2013) 49(4):764–6. doi: 10.1016/j.jesp.2013.03.013

CrossRef Full Text | Google Scholar

38. Mullineaux DR, Irwin G. Error and anomaly detection for intra-participant time-series data. Int Biomech. (2017) 4(1):28–35. doi: 10.1080/23335432.2017.1348913

CrossRef Full Text | Google Scholar

39. Benson LC, Clermont CA, Watari R, Exley T, Ferber R. Automated accelerometer-based gait event detection during multiple running conditions. Sensors (Switzerland). (2019) 19(7):1–19. doi: 10.3390/s19071483

CrossRef Full Text | Google Scholar

40. Altman AR, Davis IS. A kinematic method for footstrike pattern detection in barefoot and shod runners. Gait Posture. (2012) 35(2):298–300. doi: 10.1016/j.gaitpost.2011.09.104

PubMed Abstract | CrossRef Full Text | Google Scholar

41. Oliveira AS, Pirscoveanu CI. Implications of sample size and acquired number of steps to investigate running biomechanics. Sci Rep. (2021) 11(1):1–15. doi: 10.1038/s41598-021-82876-z

PubMed Abstract | CrossRef Full Text | Google Scholar

42. Evans JD. Straightforward statistics for the behavioral sciences. Monterey: Thomson Brooks/Cole Publishing Co (1996).

43. Bertram JEA, Prebeau-Menezes L, Szarko MJ. Gait characteristics over the course of a race in recreational marathon competitors. Res Q Exerc Sport. (2013) 84(1):6–15. doi: 10.1080/02701367.2013.762259

PubMed Abstract | CrossRef Full Text | Google Scholar

44. Nicol C, Komi PV, Marconnet P. Effects of marathon fatigue on running kinematics and economy. Scand J Med Sci Sports. (1991) 1(4):195–204. doi: 10.1111/j.1600-0838.1991.tb00296.x

CrossRef Full Text | Google Scholar

45. Cavanagh PR, Kram R. Stride length in distance running: velocity, body dimensions, and addes mass effects. Med Sci Sports Exerc. (1989) 21(4):467–79. doi: 10.1249/00005768-198908000-00020

PubMed Abstract | CrossRef Full Text | Google Scholar

46. Gerritsen KGM, Van Den Bogert AJ, Nigg BM. Direct dynamics simulation of the impact phase in heel-toe running. J Biomech. (1995) 28(6):661–6. doi: 10.1016/0021-9290(94)00127-P

PubMed Abstract | CrossRef Full Text | Google Scholar

47. Reenalda J, Maartens E, Buurke JH, Gruber AH. Kinematics and shock attenuation during a prolonged run on the athletic track as measured with inertial magnetic measurement units. Gait Posture. (2019):155–60. doi: 10.1016/j.gaitpost.2018.11.020

PubMed Abstract | CrossRef Full Text | Google Scholar

48. Sheerin K, Besier T, Reid D, Hume P. The reliability and variability of three-dimensional tibial acceleration during running. 34rd International Conference on Biomechanics in Sports (2016). http://hdl.handle.net/10292/11944.

49. Bigelow EMR, Elvin NG, Elvin AA, Arnoczky SP. Peak impact accelerations during track and treadmill running. J Appl Biomech. (2013) 29(5):639–44. doi: 10.1123/jab.29.5.639

PubMed Abstract | CrossRef Full Text | Google Scholar

50. Lucas-Cuevas AG, Priego-Quesada JI, Aparicio I, Giménez JV, Llana-Belloch S, Pérez-Soriano P. Effect of 3 weeks use of compression garments on stride and impact shock during a fatiguing run. Int J Sports Med. (2015) 36(10):826–31. doi: 10.1055/s-0035-1548813

PubMed Abstract | CrossRef Full Text | Google Scholar

51. Verbitsky O, Mizrahi J, Voloshin A, Treiger J, Isakov E. Shock transmission and fatigue in human running. J Appl Biomech. (1998) 14(3):300–11. doi: 10.1123/jab.14.3.300

PubMed Abstract | CrossRef Full Text | Google Scholar

52. Derrick TR, Dereu D, Mclean SP. Impacts and kinematic adjustments during an exhaustive run. Med Sci Sports Exercise. (2002) 34(6):998–1002. doi: 10.1097/00005768-200206000-00015

CrossRef Full Text | Google Scholar

53. Milner CE, Ferber R, Pollard CD, Hamill J, Davis IS. Biomechanical factors associated with tibial stress fracture in female runners. Med Sci Sports Exerc. (2006) 5:323–8. doi: 10.1249/01.mss.0000183477.75808.92

CrossRef Full Text | Google Scholar

54. Pohl MB, Mullineaux DR, Milner CE, Hamill J, Davis IS. Biomechanical predictors of retrospective tibial stress fractures in runners. J. Biomech. (2008) 41:1160–5. doi: 10.1016/j.jbiomech.2008.02.001

PubMed Abstract | CrossRef Full Text | Google Scholar

55. Edwards WB. Modeling overuse injuries in sport as a mechanical fatigue phenomenon. Exerc Sport Sci Rev. (2018) 46(4):224–31. doi: 10.1249/JES.0000000000000163

PubMed Abstract | CrossRef Full Text | Google Scholar

56. Reenalda J, Maartens E, Homan L, Buurke JH. Continuous three dimensional analysis of running mechanics during a marathon by means of inertial magnetic measurement units to objectify changes in running mechanics. J Biomech. (2016) 49(14):3362–7. doi: 10.1016/j.jbiomech.2016.08.032

PubMed Abstract | CrossRef Full Text | Google Scholar

57. Sanno M, Willwacher S, Epro G, Brüggemann GP. Positive work contribution shifts from distal to proximal joints during a prolonged run. Med Sci Sports Exercise. (2018) 50(12):2507–17. doi: 10.1249/MSS.0000000000001707

CrossRef Full Text | Google Scholar

58. Nigg BM, Bahlsen HA, Luethi SM, Stokes S. The influence of running velocity and midsole hardness on external impact forces in heel-toe running. J Biomech. (1989) 22(8–9):963–5. doi: 10.1016/0021-9290(89)90081-X

PubMed Abstract | CrossRef Full Text | Google Scholar

59. Valiant GA. Transmission and attenuation of heelstrike accelerations. Champaign, IL: Human Kinetics Publishers (1990).

60. Schubert AG, Kempf J, Heiderscheit BC. Influence of stride frequency and length on running mechanics: a systematic review. Sports Health. (2014) 6(3):210–7. doi: 10.1177/1941738113508544

PubMed Abstract | CrossRef Full Text | Google Scholar

61. Giandolini M, Vernillo G, Samozino P, Horvais N, Edwards WB, Benoît J, et al. Fatigue associated with prolonged graded running. Eur J Appl Physiol. (2016) 116(10):1859–73. doi: 10.1007/s00421-016-3437-4

PubMed Abstract | CrossRef Full Text | Google Scholar

62. Jewell C, Boyer KA, Hamill J. Do footfall patterns in forefoot runners change over an exhaustive run? J Sports Sci. (2017) 35(1):74–80. doi: 10.1080/02640414.2016.1156726

PubMed Abstract | CrossRef Full Text | Google Scholar

63. Clermont CA, Benson LC, Edwards WB, Hettinga BA, Ferber R. New considerations for wearable technology data: changes in running biomechanics during a marathon. J Appl Biomech. (2019) 35:401–9. doi: 10.1123/jab.2018-0453

PubMed Abstract | CrossRef Full Text | Google Scholar

64. Messier SP, Martin DF, Mihalko SL, Ip E, DeVita P, Cannon DW, et al. A 2-year prospective cohort study of overuse running injuries: the runners and injury longitudinal study (TRAILS). Am J Sports Med. (2018) 46(9):2211–21. doi: 10.1177/0363546518773755

PubMed Abstract | CrossRef Full Text | Google Scholar

65. Vannatta CN, Heinert BL, Kernozek TW. Biomechanical risk factors for running-related injury differ by sample population: a systematic review and meta-analysis. Clin Biomech. (2020) 75:104991. doi: 10.1016/j.clinbiomech.2020.104991

CrossRef Full Text | Google Scholar

Keywords: marathon, kinematics, inertial measurement unit, biomechanics, acceleration, endurance

Citation: Zandbergen MA, Buurke JH, Veltink PH and Reenalda J (2023) Quantifying and correcting for speed and stride frequency effects on running mechanics in fatiguing outdoor running. Front. Sports Act. Living 5:1085513. doi: 10.3389/fspor.2023.1085513

Received: 31 October 2022; Accepted: 23 February 2023;
Published: 17 April 2023.

Edited by:

Steven van Andel, IJsselheem Foundation, Netherlands

Reviewed by:

Supej Matej, University of Ljubljana, Slovenia
Maurice Mohr, University of Innsbruck, Austria

© 2023 Zandbergen, Buurke, Veltink and Reenalda. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Marit A. Zandbergen bS56YW5kYmVyZ2VuQG9jb24ubmw=

Specialty Section: This article was submitted to Biomechanics and Control of Human Movement, a section of the journal Frontiers in Sports and Active Living

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.