Wear Behavior and Surface Quality of Dental Bioactive Ions-Releasing Resins Under Simulated Chewing Conditions

\nIsadora Martini Garcia,&#x;Isadora Martini Garcia1,2Abdulrahman A. Balhaddad,&#x;Abdulrahman A. Balhaddad2,3Noorhan AljubooriNoorhan Aljuboori4Maria Salem Ibrahim,Maria Salem Ibrahim2,5Lamia MokeemLamia Mokeem2Akudo OgubunkaAkudo Ogubunka4Fabrício Mezzomo CollaresFabrício Mezzomo Collares1Mary Anne Sampaio de Melo,
Mary Anne Sampaio de Melo2,4*
  • 1Department of Dental Materials, School of Dentistry, Federal University of Rio Grande do Sul, Porto Alegre, Brazil
  • 2Ph.D. Program in Dental Biomedical Sciences, University of Maryland School of Dentistry, Baltimore, MD, United States
  • 3Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
  • 4Division of Operative Dentistry, Department of General Dentistry, University of Maryland School of Dentistry, Baltimore, MD, United States
  • 5Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia

Bioactive materials can reduce caries lesions on the marginal sealed teeth by providing the release of ions, such as calcium, phosphate, fluoride, zinc, magnesium, and strontium. The presence of such ions affects the dissolution balance of hydroxyapatite, nucleation, and epitaxial growth of its crystals. Previous studies mostly focused on the ion-releasing behavior of bioactive materials. Little is known about their wear behavior sealed tooth under mastication. This study aimed to evaluate the wear behavior and surface quality of dental bioactive resins under a simulated chewing model and compare them with a resin without bioactive agents. Three bioactive resins (Activa, BioCoat, and Beautifil Flow-Plus) were investigated. A resin composite without bioactive agents was used as a control group. Each resin was applied to the occlusal surface of extracted molars and subjected to in vitro chewing simulation model. We have assessed the average surface roughness (Ra), maximum high of the profile (Rt), and maximum valley depth (Rv) before and after the chewing simulation model. Vickers hardness and scanning electron microscopy (SEM) also analyzed the final material surface quality). Overall, all groups had increased surface roughness after chewing simulation. SEM analysis revealed a similar pattern among the materials. However, the resin with polymeric microcapsules doped with bioactive agents (BioCoat) showed increased surface roughness parameters. The material with Surface Pre-reacted Glass Ionomer (Beautifil Flow-Plus) showed no differences compared to the control group and improved microhardness. The addition of bioactive agents may influence surface properties, impairing resin composites' functional and biological properties. Future studies are encouraged to analyze bioactive resin composites under high chemical and biological challenges in vitro with pH cycles or in situ models.

Introduction

Dental caries is the most prevalent chronic disease worldwide, affecting 60–90% of children [1]. Oral health preventive guidelines widely recommend sealing the tooth surface as a non-invasive preventive approach [2]. Dental sealants' application over the tooth surface is painless, fast, and welcomed by children [3]. Caries lesions on the marginal sealed teeth can be initiated by bacterial acids resulting in the dissolution of hydroxyapatite crystals with calcium (Ca2+) and phosphate (PO43-) ions loss [4, 5].

Bioactive resin sealants could be one of the most desirable approaches for managing caries due to the potential of providing localized ion release near the tooth surface [6]. The bioactivity of these materials can be attributed to the ionic exchange with saliva and tooth structure. The material's interactivity with the surrounding microenvironment would help maintain healthy teeth [68]. Bioactive resins are expected to provide essential ions, such as calcium and phosphate, to restore the physiological equilibrium between tooth minerals and oral fluids [9, 10]. These materials claim continuously recharge the ionic components of saliva, teeth, and the material itself. New dental materials have been developed to present biointeractivity with dental tissues to prevent caries' recurrence around sealed or restored teeth [6, 912].

In the oral environment, dental materials face many challenges to their long-term service. Fatigue wear due to the chewing process's cyclic nature causes degradation of dental materials [13]. Dental resins show a particular wear pattern because their composition's characteristics directly affect their wear resistance [14, 15]. Bioactive resins are relatively new in the dental market. Many manufacturers have intentionally added different ion releasing-sources in a range of size and concentration as an anticaries component [1618]. The variation in composition, solubility, and permeability of the bioactive resin is intended to maximize and sustain the ion release over time [10, 19, 20]. However, changes in the resin formulations to facilitate ion releasing may impact wear behavior making the material prone to physical modifications under masticatory load [18]. Few studies investigated bioactive fillers' effects in dental resins under high-challenge situations [18, 21, 22]. In this context, it is essential to consider that the oral environment and masticatory loads can induce high surface roughness, contributing to biofilm formation on the resin surface [23]. Over time, the damage on material surface ‘s properties can jeopardize the plaque removal and induce a higher biofilm development on the material.”

In this study, bioactive resins with low viscosity were applied to human teeth' occlusal surfaces to be subjected to chewing simulation and surface morphology analysis. This study aimed to evaluate the wear behavior and surface quality of dental bioactive resins under a simulated chewing model and compare them with a resin without bioactive agents.

Materials and Methods

Study Design

This study employed a completely randomized, single-blind experimental design with 10 experimental units (sealed tooth) per group. Using a computer-generated list, we randomly assigned the teeth to one of four groups, as showed in Figure 1A.

FIGURE 1
www.frontiersin.org

Figure 1. Image (A) displays an illustration of the dental resins applied in this study: bioactive resins, with an ion-releasing composition (schematic draw from 2 to 4), and a control group without ion-releasing composition (schematic draw 1). A chewing simulation machine used in this study and a representative sealed tooth with a bioactive resin on the chewing surface. Image (B) shows a tooth crown sealed with a dental resin before the chewing simulation. Image (C) displays the chewing simulation machine. The magnification shows the tooth crown sealed with the dental resin positioned in the chewing simulation machine.

The groups are described as follows: (1) A dental resin without bioactive materials was included as a control group (TPH 3 Flow, Dentsply Sirona, Milford, DE, USA), (2) Activa BioRestorative (Pulpdent, Watertown, MA, USA), (3) BioCoat (with SmartCap Technology, Plymouth Meeting, PA, USA), and (4) Beautifil Flow Plus [with Surface Pre-reacted Glass Ionomer (S-PRG) SHOFU Inc., Kyoto, Japan]. A detailed description of the composition of tested materials is displayed in Table 1. The response variables were average surface roughness (Ra), maximum high of the profile (Rt), and maximum valley depth (Rv) before and after the chewing simulation model (expressed in micrometers), surface hardness values, and surface morphology via scanning electron microscopy (SEM).

TABLE 1
www.frontiersin.org

Table 1. Composition and manufacturer of the three bioactive resin composites and the control group without bioactive agents provided by the Safety Data Sheet of each manufacturer.

Sample Preparation

The Institutional Research Board at the University of Maryland HP-00079029/approved the use of extracted human teeth for this investigation. The teeth were refrigerated at 4°C in a 0.01% (w/v) thymol solution until use. Next, using a water-cooled diamond saw and a cutting machine (IsoMet Low-Speed Saw, Buehler, Lake Bluff, IL), the teeth were cut 2 mm below the cement–enamel junction to remove the roots. The tooth crowns were inspected under ×10 magnification to ensure an occlusal surface free of cracks or defects (Leica Zoom 2000—Leica Microsystems GmbH, Wetzlar, Germany).

Phosphoric acid at 37°C was applied on the enamel of occlusal areas for 15 s, rinsed with distilled water for 15 s, and spray dried. The bonding agent (OptiBond Solo Plus, Kerr, Brea, CA) was applied using a micro brush and light-cured for 20 s. Each resin was applied on the occlusal surfaces of the teeth, a Mylar strip was placed on the top of the etched enamel, and the material was photoactivated for 20 s with a light-emitting diode with 1,200 mW/cm2 (Valo grand, Ultradent Products Inc., South Jordan, UT, USA). The occlusal area was covered entirely to obtain flat surfaces. Figure 1B displays the application of the bioactive resin over the tooth surface.

Chewing Simulation Model

Extracted teeth sealed with the tested bioactive and control resins were subjected to simulated chewing using a chewing simulator (Chewing simulator CS-4, SD Mechatronik GMBH, Feldkirchen-Westerham, Bavaria, Germany). The machine used in this study described in Figure 1C is a dual-axis chewing simulator that allows appropriate standardization of the number of cycles, load, speed, and frequency [24]. Artificial saliva was used as a lubricant medium during the chewing simulation [25]. The lubricant acts to simulate a moist oral environment and help remove wear debris generated during the chewing. The saliva solution was prepared with 1 L of distilled water and 0.1029 g of CaCl2.2H2O, 0.04066 g of MgCl2, 0.544 g of KH2PO4, 4.766 g of Hepes, 2.2365 g of KCl. The solution was mixed, and the pH was adjusted to 7 [26].

The sealed teeth were subject to a unidirectional load of 49 N, an equivalent of 5 kg, and 80,000 cycles, equivalent to almost 4 months of clinical service [24]. The upward movement was 2 mm, downward movement of 1 mm, horizontal movement of 0.7 mm, speed of upward movement of 40 mm/s, speed of downward movement of 40 mm/s, speed of horizontal movement of 40 mm/s, frequency of 1 Hz. The antagonist was a steatite tip with 6 mm of diameter, and the direction was forwards under load, backward without load.

Assessment of the Tooth Wear

Each resin's surface wear behavior before and after the chewing simulation was analyzed using a contact profilometer (Surftest SJ-310, Mitutoyo America, Aurora, IL, USA). For this purpose, five measurements were performed at the center of each occlusal area. Standard roughness calibration specimen was used for calibration. The measurements were performed with a stylus tip of 5 μm at 0.5 mm/s. A force of 4 mN was applied with a cut-off of 0.25 and 1.5-mm tracing length [27]. The following parameters were assessed:

Average Surface Roughness (Ra)

Ra represents the arithmetical mean of the profile deviations' absolute values from the roughness profile's mean line.

Maximum High of the Profile (Rt)

Rt measures the difference between the maximum peak height and the maximum valley depth. Rt is used to detect any measure discrepancy in the surface of the sample.

Maximum Valley Depth (Rv)

Rv measures the deepest valley produced by the chewing simulation. A high Rv value means a high amount of wear.

With the measurements pre- and post-chewing simulation, it was possible to analyze Ra, Rv, and Rt's variation for each tooth and each group (ΔRa, ΔRv, and ΔRt). The variation (delta-Δ) was calculated via subtracting the final values minus the initial ones. The results were expressed in μm.

Vickers Hardness (Indentation Modulus) of Bioactive Resins After Chewing

Besides wear and surface roughness evaluations, the resins were assessed via indentation modulus after chewing simulation. The Vickers hardness test method allows for a rapid and precise assessment of the material's resistance to deformation. This method consists of indenting the test material with a diamond indenter, a pyramid with a square base, and an angle of 136° between opposite faces subjected to a test force of between 1 gf and 100 kgf [28]. Equation (1) was used to calculate the Vickers hardness:

HV=FA= 2F.sin136°2d2    (1)

In which “F” is the applied force, and “A” is the printed square area on the polymer surface calculated by measuring its diagonals.

Five samples of each per group were analyzed, and the measurements were performed using a Vickers indenter with 25 g for 10 s (microhardness tester, HMV-G, Shimadzu Corp., Tokyo, Japan). Five indentations were completed on each resin on the teeth. The average hardness value for each resin per group was calculated.

Analysis of Surface Morphology via Scanning Electron Microscopy (SEM)

One sample per group was qualitatively analyzed via SEM. Each representative sample was mounted on aluminum stubs with carbon conductive double-face adhesive tapes and sputter-coated with 10–20 nm of platinum/Palladium in a sputter coater (EMS 150T ES, Electron Microscopy Sciences, PA). SEM images were taken in a scanning electron microscope (Quanta 200 FEI Company, Hillsboro, OR, USA) under 100 and 2,000× magnification.

Statistical Analysis

The software SigmaPlot, version 12.0 (Systat Software, Inc., San Jose, CA, USA), was used to analyze the data. Initially, the assumptions of equality of variances (Levene's test) and the data distribution (the Shapiro-Wilk test) were verified.

The difference between pre- and post-Ra, Rt, or Rv within each group was analyzed via paired t-tests. For comparison among the groups within pre-reading and post-reading data, pre-Ra and pre-Rt were compared via Kruskal-Wallis, while pre-Rv was compared via One-Way ANOVA. When a significant difference was noted, Dunn's test was used as post-hoc for Kruskal-Wallis, while Tukey's test was applied as post-hoc for One-Way ANOVA.

Post-Ra, post-Rt, and post-Rv were also analyzed among the groups of resins. Post-Ra was analyzed via One-Way ANOVA with Tukey's post-hoc test. Post-Rt and post-Rv were analyzed via Kruskal-Wallis, and Dunn's test was applied when there was a significant difference among groups.

ΔRa was analyzed among groups via One-Way ANOVA and Tukey's test, ΔRt was analyzed among groups via One-Way ANOVA, and ΔRv was analyzed among groups via Kruskal-Wallis. The Vickers hardness was tested via One-Way ANOVA and Tukey's test among groups. A significance level of 0.05 was considered for all tests.

Results

In the roughness analysis, all groups of bioactive resins showed higher Ra and Rv after the chewing simulation compared to the initial values (p < 0.05) (Figure 2). The roughness parameter Rt also showed significantly higher values after the chewing simulation for the control group, Activa, and Beautifil groups (p < 0.05). The resin BioCoat showed no statistically significant difference between pre and post-Rt (p > 0.05).

FIGURE 2
www.frontiersin.org

Figure 2. Results of tooth wear assessment. The data of pre- and post-surface via paired t-tests. Image (A) displays the results of pre- and post-Ra, Rt, and Rv for the control group, the TPH bioactive resin. Image (B) displays the results of pre- and post-Ra, Rt, and Rv for the Activa bioactive resin. Image (C) displays the results of pre- and post-Ra, Rt, and Rv for the BioCoat bioactive resin. Image (D) displays the results of pre- and post-Ra, Rt, and Rv for the Beautifil Flow-Plus bioactive resin. Different letters indicate a statistically significant difference between pre- and post-Ra, or pre- and post-Rt, or pre- and post-Rv within each group (p < 0.05).

The resin composite Beautifil showed lower surface roughness in comparison to BioCoat for all three surface parameters (p < 0.05), and there was no difference among the control, Activa, and BioCoat groups in Pre-Ra, pre-Rt, and pre-Rv (p > 0.05) (Figure 3). Post-Ra, post-Rt, and post-Rv showed different behavior, with a statistical difference among groups only for post-Ra (p < 0.05).

FIGURE 3
www.frontiersin.org

Figure 3. Results of tooth wear assessment. The data of pre- or post-surface roughness parameters among groups of bioactive resins were compared via One-Way ANOVA or Kruskall-Wallis. Post-hoc tests were applied when a significant difference was noted. Image (A) displays the results of pre-Ra, pre-Rt, and pre-Rv among groups. Different letters indicate statistically significant differences among groups of bioactive resins within each surface roughness parameter (pre-Ra, or pre-Rt, or pre-Rv) (p < 0.05). Image (B) displays the results of post-Ra, post-Rt, and post-Rv among groups. Different letters indicate statistically significant differences among groups of bioactive resins within each surface roughness parameter (post-Ra, or post-Rt, or post-Rv) (p < 0.05).

The difference between pre-and post-surface roughness parameters is expressed as ΔRa, ΔRt, and ΔRv in Figure 4. There was a statistically significant difference among groups for ΔRa (p < 0.05). In this analysis, the control group TPH, which was the only bioactive resin without bioactive fillers, showed no statistical difference for Activa and Beautifil (p > 0.05). The group BioCoat had higher ΔRa than the control group (p < 0.05). There were no differences among groups for ΔRt or ΔRv (p > 0.05). However, it was clear that the BioCoat group showed the highest standard-deviation values among the resins.

FIGURE 4
www.frontiersin.org

Figure 4. Results of tooth wear assessment via surface roughness variation (Δ = delta calculation). The data for each roughness parameter (Ra, Rt, or Rv) were compared via One-Way ANOVA or Kruskall-Wallis. Post-hoc tests were applied when a significant difference was noted. Image (A) shows the difference of ΔRa among groups. Image (B) shows the difference of ΔRt among groups. Image (C) shows the difference of ΔRv among groups. Different letters indicate statistically significant differences among groups within each surface roughness parameter (Δ-Ra, or Δ-Rt, or Δ-Rv) (p < 0.05).

There was a statistically significant difference among groups considering the Vickers hardness (p < 0.05) (Figure 5). The values ranged from 27.36 (±4.77) for Activa to 41.56 (±2.44) for Beautifil (p < 0.05). The control group, Activa, and BioCoat showed no differences for Vickers hardness (p > 0.05), and all these three bioactive resins presented lower results than Beautifil (p < 0.05).

FIGURE 5
www.frontiersin.org

Figure 5. (A) Optical image of a standard Vickers indentation on the composite surface. (B) Means and standard values for the Vickers surface hardness for all tested groups. Different letters indicate statistically significant difference among groups for Vickers hardness (p < 0.05).

Regarding the surface morphology (Figure 6), all groups exhibited a characteristic surface alteration in the contact area during the chewing simulation, as observed in the images at 100× magnification. More defects with larger cracks are observed for the control and Activa groups, following by Beautifil and Biocoat. However, all groups presented an irregular morphology identified with the highest magnification (2,000×).

FIGURE 6
www.frontiersin.org

Figure 6. Representative scanning electron microscopy (SEM) images of the control group and bioactive resins: Activa, BioCoat, and Beautifil. Upper images were acquired with 100× magnification. Images on the bottom were acquired with 2,000× magnification.

Discussion

The main advantage of bioactive resins is to drive an ecological shift inside biofilms toward non-dysbiotic conditions. Therefore, a higher pH and ions' availability could reduce the chances of bacteria adherence, biofilm formation and increase dental remineralization chances [29]. However, the wear phenomenon may change resins' surface properties over time. The cyclic wear phenomenon of dental materials is a gradual material removal from the restored surface due to the interaction of teeth against each other during movement [15]. Clinical wear is a complex process involving two-and-three-body wear and is influenced by materials' composition, antagonist properties, diet, and applied force [15]. Dental materials exhibit different wear mechanisms while underwear conditions in vitro [30, 31]. None of these standing mechanisms can completely simulate the clinical wear process [30]. Consequently, a straight correlation between the clinical and in vitro wear tests remains a challenge [32].

Therefore, in vitro studies on wear aim to rank restorative materials about their wear resistance and understand the wear behavior under particular simulated clinical conditions [33]. Simulating clinical settings, such as masticatory load and saliva, the in vitro chewing testings provide valuable inputs on planning new products and evaluating materials. In the current research, a Willytec simulator was set up to exert particular wear mimicking ~4 months of occlusal movements over the sealed teeth.

As an outcome, the Beautifil group showed improved outcomes compared to Activa and Bioactive, with lower roughness before or after the chewing simulation, and without differences for the control group (Figure 3). Here, the tested materials differ regarding the composition and their content (Table 1). For instance, resin-based material comprises a three-phase system, mainly composed of filler particles, resin matrix, and the coupling agent used to bond the first two elements [34]. According to the manufacturer, Beautifil is considered a Giomer because it has a high content of surface pre-reacted glass ionomer (S-PRG) particles with 0.01–4 μm, able to release and recharge fluoride. Although all groups contain dimethacrylates and inorganic filler in their composition, the wear resistance performance of Beautifil may be due to an enhanced filler distribution on the resin matrix or a difference in the filler size leading to homogeneity and maintenance of surface properties.

The parameter Rv, which measures the deepest valley, was increased for all groups after chewing simulation (Figure 2), suggesting a loss of material on the surface for the control, Activa, BioCoat, and Beautifil. Even though there was no difference for ΔRv regardless of the bioactive resin group (Figure 4), BioCoat, showed a high standard deviation value (mean ± SD = 1.61 ± 1.48 μm). The high variation for this group may be related to its wear process, and consequently, loss of particles or resin itself. The SEM images of the worn surfaces are suggestive of wear scars and debris.

Similarly, the Rt parameter indicates the difference between the maximum peak height and the maximum valley depth, increased for the control, Activa, and Beautifil. At the same time, BioCoat did not show a statistical difference between pre and post-chewing. The high standard-deviation value for this bioactive resin in Rv and Rt probably reflects the discrepancies in BioCoat surface roughness (Figure 2). Like the Rv outcome, ΔRt also showed a high standard-deviation (Figure 4), suggesting that the material probably offers an irregular surface.

The evaluation of roughness average (Ra) is a common approach to test the surface of dental materials and how the environment impacts their surface's properties [35]. An increased roughness is usually more prone to microorganisms colonization and biofilm formation [18, 36, 37]. Bioactive resins, such as those tested here, will contact the enamel inside the mouth. The increased roughness may be a challenge for hygiene control, negatively impacting caries prevention. Therefore, the maintenance of roughness is also crucial for biofilm control. In this study, all groups showed a high initial roughness. The Mylar strip before resins' photoactivation during sample preparation should have helped achieve the smoothest possible surface. Different bioactive resins previously showed varied roughness depending, for instance, on their quantity of fillers [22, 38]. The fillers' heterogeneity, content, size, or shape probably led to the present study's high roughness. It is noteworthy that Beautifil resin presented lower initial and final Ra compared to Activa and BioCoat. This resin had no difference for the control group (resin without bioactive fillers). As aforementioned, the fillers' properties and the composites' solubility may differ among groups, leading to higher wear and Ra for Activa and BioCoat.

Beautifil contains S-PRG particles, which are bioactive fillers able to release ions, mainly boron and fluoride [39, 40]. Activa releases and recharges calcium, phosphate, and fluoride, while BioCoat has resin-based microcapsules filled with ionic solutions of fluoride, calcium, and phosphate [41]. Beautifil may show better smoothness compared to BioCoat and Activa but also has superior physicochemical stability. Therefore, the initial roughness is decreased for this resin, and the variation and the final roughness. On the other hand, the polymeric microcapsules of BioCoat may are not well-distributed as inorganic fillers of the other bioactive resins and may have released the bioactive agents from the core during the chewing simulation, increasing the variation intragroup. The variation that occurs depending on the resins' chemical formulation may have contributed to the non-normal distribution of data for some parameters.

Interestingly, a previous study [18] investigated another resin from the same brand, Beautifil II, containing S-PRG particles. The authors observed a higher porosity and roughness for Beautifil II than a conventional glass-ionomer cement (Fuji IX GP EXTRA, Tokyo, Japan) and a conventional resin (Herculite XRV Ultra, Kerr, Orange, CA, USA). The higher porosity of Beautifil was even pronounced when the materials were immersed in lactic acid, a standard caries-related bacterial end product of sugar metabolism.

After the chewing simulation, the resins were also analyzed via microhardness and SEM. There was no statistical difference among the control group, Activa, and BioCoat, with significantly higher values for Beautifil (Figure 5). The resin-based materials' hardness depends on materials chemical properties, such as the degree of conversion of carbon-carbon double bonds of methacrylate groups and crosslinking density. Moreover, the filler content and distribution on the surface influences materials' hardness. It is not possible to assure if the difference found was due to S-PRG incorporation, total inorganic content, or variation of polymeric chains. The Beautifil group showed a roughness compatible with the control group before and after the chewing simulation and a superior microhardness compared to the other bioactive resins.

SEM analysis was performed in one sample per group as qualitative and additional information. Interestingly, in the analyzed samples, BioCoat did not present defects, such as the other groups. This result can be related to the higher standard-deviation values for this group than the control and the other bioactive resins. A deeper understanding of these bioactive resins under cariogenic challenges could help plan and develop therapeutic materials.

This study selected three bioactive materials to evaluate, although an increasing number of bioactive materials exist in the market. Therefore, readers must be aware of over-generalizations since we understand that resin composites formulations are highly heterogeneous. Also, we applied 80,000 cycles during the loading. However, the cycle range used in the literature can vary. Different loading cycles within the wide range of 5,000–1,200,000 cycles are described in the literature as ideal for the initial simulation of in vivo chewing [42]. Moreover, even though the artificial saliva used has been reported in a previous study [26], sterilized saliva or mucin-containing saliva could be applied to analyze the wear under loading. More complex saliva could better mimic the oral environment, mainly because of the ions exchange and wear process complexity under chewing simulation.

Conclusion

In this in vitro study, the use of the two-body wear simulation model revealed initial information on ion-releasing bioactive resins' wear behavior for the first time. The bioactive resin containing S-PRG particles did not differ from the control and showed the highest microhardness. Overall, bioactive resins may not have inferior wear behavior and surface quality compared to non-bioactive conventional resin. Future studies investigating the filler's content in the filler particles' matrix and size incorporated into bioactive resins are encouraged.

Data Availability Statement

The original contributions generated for the study are included in the article/supplementary material, further inquiries can be directed to the corresponding author/s.

Ethics Statement

The studies involving human participants were reviewed and approved by University of Maryland Baltimore Institutional Research Board. Written informed consent for participation was not required for this study in accordance with the national legislation and the institutional requirements.

Author Contributions

IG and AB processed the experimental data, performed the analysis, drafted the manuscript, and designed the figures. NA, MI, LM, and AO performed the measurements. FC and MdM were involved in planning, supervising the work, and interpreting the results and worked on the manuscript. All authors contributed to the article and approved the submitted version.

Conflict of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Acknowledgments

We thank the University of Maryland School of Medicine Center for Innovative Biomedical Resources-Baltimore, Maryland-UMB Electron Microscopy Core Imaging Facility on behalf Dr. Ru-ching Hsia for assistance with SEM. We also gratefully acknowledge the access to the microhardness tester of Biomaterials and Tissue Engineering lab facilities on behalf Drs. Michael Weir and Hockin Xu. AB and MI acknowledge the scholarship during their Ph.D. studies from the Imam AbdulRahman bin Faisal University, Dammam, Saudi Arabia, and the Saudi Arabia Cultural Mission (SACM). IG acknowledges the scholarship from the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior—Brasil (CAPES)—Finance Code 001 during her Ph.D. studies.

References

1. WHO. Oral Health Fact Sheet. (2012). Available online at: http://wwwwhoint/mediacentre/factsheets/fs318/en/

Google Scholar

2. Splieth CH, Banerjee A, Bottenberg P, Breschi L, Campus G, Ekstrand KR, et al. How to intervene in the caries process in children: a joint ORCA and EFCD Expert Delphi consensus statement. Caries Res. (2020) 54:297–305. doi: 10.1159/000507692

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Ahovuo-Saloranta A, Forss H, Walsh T, Nordblad A, Mäkelä M, and Worthington HV. Pit and fissure sealants for preventing dental decay in permanent teeth. Cochrane Database Syst Rev. (2017) 7:Cd001830. doi: 10.1002/14651858.CD001830.pub5

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Cehreli ZC, and Gungor HC. Quantitative microleakage evaluation of fissure sealants applied with or without a bonding agent: results after four-year water storage in vitro. J Adhes Dent. (2008) 10:379–84.

PubMed Abstract | Google Scholar

5. Featherstone JD. Dental caries: a dynamic disease process. Aust Dent J. (2008) 53:286–91. doi: 10.1111/j.1834-7819.2008.00064.x

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Yang SY, Kwon JS, Kim KN, and Kim KM. Enamel surface with pit and fissure sealant containing 45S5 bioactive glass. J Dent Res. (2016) 95:550–7. doi: 10.1177/0022034515626116

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Braga RR. Calcium phosphates as ion-releasing fillers in restorative resin-based materials. Dent Mater. (2019) 35:3–14. doi: 10.1016/j.dental.2018.08.288

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Vallittu PK, Boccaccini AR, Hupa L, and Watts DC. Bioactive dental materials–do they exist and what does bioactivity mean? Dent Mater. (2018) 34:693–4. doi: 10.1016/j.dental.2018.03.001

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Balhaddad AA, Kansara AA, Hidan D, Weir MD, Xu HHK, and Melo MAS. Toward dental caries: exploring nanoparticle-based platforms and calcium phosphate compounds for dental restorative materials. Bioact Mater. (2019) 4:43–55. doi: 10.1016/j.bioactmat.2018.12.002

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Braga RR, and Fronza BM. The use of bioactive particles and biomimetic analogues for increasing the longevity of resin-dentin interfaces: a literature review. Dent Mater J. (2020) 39:62–8. doi: 10.4012/dmj.2019-293

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Bendary IM, Garcia IM, Collares FM, Takimi A, Samuel SMW, and Leitune VCB. Wollastonite as filler of an experimental dental adhesive. J Dent. (2020) 102:103472. doi: 10.1016/j.jdent.2020.103472

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Ibrahim MS, Balhaddad AA, Garcia IM, Collares FM, Weir MD, Xu HHK, et al. pH-responsive calcium and phosphate-ion releasing antibacterial sealants on carious enamel lesions in vitro. J Dent. (2020) 97:103323. doi: 10.1016/j.jdent.2020.103323

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Drummond JL. Degradation, fatigue, and failure of resin dental composite materials. J Dent Res. (2008) 87:710–9. doi: 10.1177/154405910808700802

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Cao L, Zhao X, Gong X, and Zhao S. An in vitro investigation of wear resistance and hardness of composite resins. Int J Clin Exp Med. (2013) 6:423–30.

PubMed Abstract | Google Scholar

15. Tsujimoto A, Barkmeier WW, Fischer NG, Nojiri K, Nagura Y, Takamizawa T, et al. Wear of resin composites: current insights into underlying mechanisms, evaluation methods and influential factors. Jpn Dent Sci Rev. (2018) 54:76–87. doi: 10.1016/j.jdsr.2017.11.002

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Harhash AY, ElSayad II, and Zaghloul AGS. A comparative in vitro study on fluoride release and water sorption of different flowable esthetic restorative materials. Eur J Dent. (2017) 11:174–9. doi: 10.4103/ejd.ejd_228_16

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Sokolowski K, Szczesio-Wlodarczyk A, Bociong K, Krasowski M, Fronczek-Wojciechowska M, Domarecka M, et al. Contraction and hydroscopic expansion stress of dental ion-releasing polymeric materials. Polymers (Basel). (2018) 10:1093. doi: 10.3390/polym10101093

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Yoshihara K, Nagaoka N, Maruo Y, Sano H, Yoshida Y, and Van Meerbeek B. Bacterial adhesion not inhibited by ion-releasing bioactive glass filler. Dent Mater. (2017) 33:723–34. doi: 10.1016/j.dental.2017.04.002

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Dorozhkin SV. Bioceramics of calcium orthophosphates. Biomaterials. (2010) 31:1465–85. doi: 10.1016/j.biomaterials.2009.11.050

CrossRef Full Text | Google Scholar

20. Dorozhkin SV. Calcium orthophosphates in dentistry. J Mater Sci Mater. (2013) 24:1335–63. doi: 10.1007/s10856-013-4898-1

CrossRef Full Text | Google Scholar

21. Bansal R, Burgess J, and Lawson NC. Wear of an enhanced resin-modified glass-ionomer restorative material. Am J Dent. (2016) 29:171–4.

PubMed Abstract | Google Scholar

22. Gómez MMM, Garcia IM, Leitune VCB, and Collares FM. Surface and mechanical properties of adhesives with calcium phosphates challenged to different storage media. Braz J Oral Sci. (2020) 19:1–11. doi: 10.20396/bjos.v19i0.8660181

CrossRef Full Text | Google Scholar

23. Glauser S, Astasov-Frauenhoffer M, Müller JA, Fischer J, Waltimo T, and Rohr N. Bacterial colonization of resin composite cements: influence of material composition and surface roughness. Eur J Oral Sci. (2017) 125:294–302. doi: 10.1111/eos.12355

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Ho TK, Satterthwaite JD, and Silikas N. The effect of chewing simulation on surface roughness of resin composite when opposed by zirconia ceramic and lithium disilicate ceramic. Dent Mater. (2018) 34:e15–24. doi: 10.1016/j.dental.2017.11.014

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Passos VF, Melo MA, Vasconcellos AA, Rodrigues LK, and Santiago SL. Comparison of methods for quantifying dental wear caused by erosion and abrasion. MRT. (2013) 76:178–83. doi: 10.1002/jemt.22150

PubMed Abstract | CrossRef Full Text | Google Scholar

26. Ionta FQ, Mendonça FL, de Oliveira GC, de Alencar CR, Honório HM, Magalhães AC, et al. In vitro assessment of artificial saliva formulations on initial enamel erosion remineralization. J Dent. (2014) 42:175–9. doi: 10.1016/j.jdent.2013.11.009

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Melo MA, Codes BM, Passos VF, Lima JP, and Rodrigues LK. In situ response of nanostructured hybrid fluoridated restorative composites on enamel demineralization, surface roughness and ion release. Eur J Prosthodont Restor Dent. (2014) 22:185–90. doi: 10.1922/EJPRD_1390Rodrigues06

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Ilie N, Hilton TJ, Heintze SD, Hickel R, Watts DC, Silikas N, et al. Academy of dental materials guidance-resin composites: part I-mechanical properties. Dent Mater. (2017) 33:880–94. doi: 10.1016/j.dental.2017.04.013

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Ionescu AC, Hahnel S, Cazzaniga G, Ottobelli M, Braga RR, Rodrigues MC, et al. Streptococcus mutans adherence and biofilm formation on experimental composites containing dicalcium phosphate dihydrate nanoparticles. J Mater Sci Mater. (2017) 28:108. doi: 10.1007/s10856-017-5914-7

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Branco AC, Colaço R, Figueiredo-Pina CG, and Serro AP. A state-of-the-art review on the wear of the occlusal surfaces of natural teeth and prosthetic crowns. Materials (Basel). (2020) 13:3525. doi: 10.3390/ma13163525

PubMed Abstract | CrossRef Full Text | Google Scholar

31. Jin S, Choi JW, Jeong CM, Huh JB, Lee SH, Lee H, et al. Evaluating the wear of resin teeth by different opposing restorative materials. Materials (Basel). (2019) 12:3684. doi: 10.3390/ma12223684

PubMed Abstract | CrossRef Full Text | Google Scholar

32. Souza JAd, Dolavale LC, and Camargo SAdS. Wear mechanisms of dental composite restorative materials by two different in-vitro methods. Mater Res. (2013) 16:333–40. doi: 10.1590/S1516-14392012005000183

CrossRef Full Text | Google Scholar

33. Heintze SD, Zellweger G, Grunert I, Munoz-Viveros CA, and Hagenbuch K. Laboratory methods for evaluating the wear of denture teeth and their correlation with clinical results. Dent Mater. (2012) 28:261–72. doi: 10.1016/j.dental.2011.10.012

PubMed Abstract | CrossRef Full Text | Google Scholar

34. Matinlinna JP, Lung CYK, and Tsoi JKH. Silane adhesion mechanism in dental applications and surface treatments: a review. Dent Mater. (2018) 34:13–28. doi: 10.1016/j.dental.2017.09.002

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Hsu KL, Balhaddad AA, Garcia IM, Collares FM, DePaola L, and Melo MA. Assessment of surface roughness changes on orthodontic acrylic resins by all-in-one spray disinfectant solutions. J Dent Res Dent Clin Dent Prospects. (2020) 14:77–82. doi: 10.34172/joddd.2020.019

PubMed Abstract | CrossRef Full Text | Google Scholar

36. Bayrak GD, Sandalli N, Selvi-Kuvvetli S, Topcuoglu N, and Kulekci G. Effect of two different polishing systems on fluoride release, surface roughness and bacterial adhesion of newly developed restorative materials. J Esthet Restor Dent. (2017) 29:424–34. doi: 10.1111/jerd.12313

PubMed Abstract | CrossRef Full Text | Google Scholar

37. Schmidlin PR, Müller P, Attin T, Wieland M, Hofer D, and Guggenheim B. Polyspecies biofilm formation on implant surfaces with different surface characteristics. J Appl Oral Sci. (2013) 21:48–55. doi: 10.1590/1678-7757201302312

PubMed Abstract | CrossRef Full Text | Google Scholar

38. Garoushi S, Vallittu PK, and Lassila L. Characterization of fluoride releasing restorative dental materials. Dent Mater J. (2018) 37:293–300. doi: 10.4012/dmj.2017-161

PubMed Abstract | CrossRef Full Text | Google Scholar

39. Hajira NSWN, and Meena N. GIOMER-the intelligent particle (new generation glass ionomer cement). Int J Dent Oral Health. (2015) 2:1–5. doi: 10.16966/2378-7090.166

CrossRef Full Text | Google Scholar

40. Shimazu K, Ogata K, and Karibe H. Evaluation of the ion-releasing and recharging abilities of a resin-based fissure sealant containing S-PRG filler. Dent Mater J. (2011) 30:923–7. doi: 10.4012/dmj.2011-124

PubMed Abstract | CrossRef Full Text | Google Scholar

41. Burbank BD, Cooper RL, Kava A, Hartjes JM, McHale WA, Latta MA, et al. Ion release and in vitro enamel fluoride uptake associated with pit and fissure sealants containing microencapsulated remineralizing agents. Am J Dent. (2017) 30:59–64.

PubMed Abstract | Google Scholar

42. Koletsi D, Iliadi A, Eliades T, and Eliades G. In vitro simulation and in vivo assessment of tooth wear: a meta-analysis of in vitro and clinical research. Materials (Basel). (2019) 12:3575. doi: 10.3390/ma12213575

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: polymers, dental caries, composite resins, fluorides wear behavior of dental bioactive resins, ion releasing

Citation: Garcia IM, Balhaddad AA, Aljuboori N, Ibrahim MS, Mokeem L, Ogubunka A, Collares FM and Melo de MAS (2021) Wear Behavior and Surface Quality of Dental Bioactive Ions-Releasing Resins Under Simulated Chewing Conditions. Front. Oral. Health 2:628026. doi: 10.3389/froh.2021.628026

Received: 10 November 2020; Accepted: 25 January 2021;
Published: 12 February 2021.

Edited by:

Katherine C. M. Leung, The University of Hong Kong, Hong Kong

Reviewed by:

Andrei Cristian Ionescu, University of Milan, Italy
Laura Ceballos, Rey Juan Carlos University, Spain

Copyright © 2021 Garcia, Balhaddad, Aljuboori, Ibrahim, Mokeem, Ogubunka, Collares and Melo. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Mary Anne Sampaio de Melo, bW1lbG8mI3gwMDA0MDt1bWFyeWxhbmQuZWR1

These authors have contributed equally to this work

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.