Front. Rehabil. Sci., 26 July 2023
Sec. Interventions for Rehabilitation

Spatiotemporal parameters from remote smartphone-based gait analysis are associated with lower extremity functional scale categories

\r\nGabriela Rozanski
Gabriela Rozanski*Andrew Delgado&#x;Andrew DelgadoDavid Putrino\r\nDavid Putrino
  • Department of Rehabilitation and Human Performance, Icahn School of Medicine at Mount Sinai, New York, NY, United States

Objective: Self-report tools are recommended in research and clinical practice to capture individual perceptions regarding health status; however, only modest correlations are found with performance-based results. The Lower Extremity Functional Scale (LEFS) is one well-validated measure of impairment affecting physical activities that has been compared with objective tests. More recently, mobile gait assessment software can provide comprehensive motion tracking output from ecologically valid environments, but how this data relates to subjective scales is unknown. Therefore, the association between the LEFS and walking variables remotely collected by a smartphone was explored.

Methods: Proprietary algorithms extracted spatiotemporal parameters detected by a standard integrated inertial measurement unit from 132 subjects enrolled in physical therapy for orthopedic or neurological rehabilitation. Users initiated ambulation recordings and completed questionnaires through the OneStep digital platform. Discrete categories were created based on LEFS score cut-offs and Analysis of Variance was applied to estimate the difference in gait metrics across functional groups (Low-Medium-High).

Results: The main finding of this cross-sectional retrospective study is that remotely-collected biomechanical walking data are significantly associated with individuals' self-evaluated function as defined by LEFS categorization (n = 132) and many variables differ between groups. Velocity was found to have the strongest effect size.

Discussion: When patients are classified according to subjective mobility level, there are significant differences in quantitative measures of ambulation analyzed with smartphone-based technology. Capturing real-time information about movement is important to obtain accurate impressions of how individuals perform in daily life while understanding the relationship between enacted activity and relevant clinical outcomes.

1. Introduction

As a fundamental aspect of daily life with significant health implications, mobility is routinely assessed in various clinical settings across diverse patient populations to inform therapeutic management (1). Lower extremity injury, neurological disease or musculoskeletal disorders can affect movement in so many different ways that accurate and thorough characterization of deficits is essential (2, 3). An individual's function, here defined as sensorimotor ability to perform everyday tasks (e.g., self-care, housework, ambulating), determines level of independence and long-term outcomes (4). Both objective and subjective functional measures are valuable in providing information about disability or recovery over time, though may reflect distinct domains of physical impairment, activity limitation or participation outlined by the World Health Organization's biopsychosocial (ICF) model/framework (5). Ambulation is a major focus in therapy with wide-ranging implications. Specific features of gait yield valuable insights about underlying physiological processes, reveal divergence from normative patterns such as unequal weight-bearing after stroke and contribute to decision-making for orthopedic conditions (6). In particular, speed has been termed the “sixth vital sign” that predicts future consequences, including falls and hospitalization (2). Asymmetry (i.e., inter-limb imbalance) is also a useful indicator of pathology (7).

Until recently, quantitative biomechanical data could only be obtained with expensive and advanced laboratory equipment, which restricted accessibility for most clinicians. In addition, often limited actionable insights are garnered from these metrics to appreciably change the course of a rehabilitation plan. New motion sensor technology now allows spontaneous monitoring of patients in more ecologically valid environments like home or the community (812). The inertial measurement unit (IMU) of smartphones can collect kinematic and spatiotemporal parameters for real-time analysis without the need for costly and inconvenient wearable devices (1317). This unsupervised, “sensing in context” strategy also avoids potential “Hawthorne/research participant effects” that can influence behavior in the presence of an evaluator (18). While users are aware of recording if software provides prompts to initiate, so-called “background” modes when enabled could further reduce observer bias. Gait assessment performed remotely through mobile applications may be used by therapists to diagnose abnormalities, track disease progression or examine the efficacy of an intervention (1925). As an emerging approach, continued work is necessary to more widely implement and utilize the information best for therapeutic purposes.

Still, the enacted activity metrics obtained with these novel systems do not represent a subject's full experience, for example pain and other personal factors that impact well-being. Self-report tools, intended to efficiently capture individual perceptions regarding overall health or disease-specific status, are recommended for research trials and routine clinical use (26, 27); however, there is evidence for only modest cross-sectional and longitudinal correlations with performance-based results (28, 29). During rehabilitation (eg. after joint replacement surgery), reliable indicators of progress are particularly important such that the relationship between standard questionnaires and physical ability outcomes in detecting change over time is increasingly studied to inform care practices (3033). The Lower Extremity Functional Scale (LEFS) is one well-validated measure of impairment affecting physical activities, applicable to a wide spectrum of pathology, that demonstrates excellent reliability and high concordance with related constructs (34, 35). Yet, the relationship to common objective tests evaluating only a single domain of interest through simple time or summary scores is weak (3638). Few studies incorporate the comprehensive output from motion trackers (39) so more knowledge about how this data relates to subjective scales is needed for appropriate interpretation by health professionals using both results in patient assessment.

The smartphone-based paradigm employed herein provides a unique opportunity for subjects to drive research about free-living mobility outside of controlled settings. Unsupervised movement recording through a readily available consumer device with clear on-screen instructions allows large datasets, otherwise limited by gait lab access, to be accumulated. Before widespread use on a general or at-risk population level, understanding the clinical relevance of this methodology is crucial. Our aim was to determine how remotely captured spatiotemporal parameters relate to perceived lower limb task ability. Therefore, an exploratory analysis was conducted to investigate the association between functional category derived from the LEFS and gait variables, both obtained through a mobile application (OneStep). Since ambulation relies on integrity of the lower body and multiple items on the questionnaire are pertinent to walking, we hypothesized that these measures would have good convergent validity.

2. Materials and methods

The de-identified data included in this analysis, from patients working with a physical therapist as part of OneStep's clinical program for at least two weeks during the period of May 2021 to November 2021, were deemed exempt by the Institutional Review Board (Icahn School of Medicine at Mount Sinai, New York, U.S.A.; STUDY-21-01466). While not systematically documented, the most common reason for rehabilitation in this cohort was joint replacement surgery (hip or knee), with a smaller proportion affected by stroke or other neurological condition.

OneStep is an FDA-registered app (available on Google Play and the iOS App Store) that uses a smartphone's integrated IMU (sampling rate 100 Hz) to collect three-dimensional acceleration, angular velocity and magnetic intensity variables. Proprietary algorithms then extract timestamped spatiotemporal parameters based on a user's motion/activity and position of the device (left/right front or back pockets). No calibration is necessary and turns are automatically detected to omit before processing so only straight path walking can be retained. After gait cycle segmentation, the following variables were calculated: cadence, velocity, hip range, base width, step and stride lengths, stance and double support times. Asymmetries of stance, step length and double support were defined as the difference between left and right sides. Validity and reliability of this approach compared to standard quantitative gait evaluation metrics has recently been shown (4042). Various iPhone and Android devices were utilized in these studies and internal testing has confirmed that different phone models do not impact algorithm performance.

Engagement with the OneStep app is expected to vary across users based on personal factors and individualized exercise plans but all subjects interacted with a similar version of the software. There was no location control for independent home use. While enrolled in physical therapy (duration subject to adherence and treating clinician's rationale), patients were prompted daily to initiate ambulation recordings with the press of a “Start” button in the application (followed by instructions to walk in a straight line for 30–45 s) and notified via pop-up screen to complete the LEFS digital questionnaire on a tri-weekly basis. As a self-assessment tool comprising 20 items that are rated on a five-point difficulty scale, LEFS scores range from zero to 80 and provide subjective measurement about the ability to perform lower body activities (34). Through a functional staging approach reflective of the instrument's structure, psychometric properties and distribution of normative values, discrete categories were created (4345). Based on numerical value of the questionnaire's response levels, cut-off points at 20, 40, and 60 delineated LEFS groups consistent with a total if the same option was assigned for all answers [quite a bit (1), moderate (2), and a little bit of difficulty (3), respectively]. To achieve size uniformity accounting for skewness of this dataset (see Figure 1), the lower two categories (a little bit or no difficulty with the activity) were grouped together, which resulted in three function ranks facilitating efficient clinical interpretation according to tallied sum: Low (0–20), Medium (21–40), High (41–80). Previous work has similarly simplified the original LEFS rating scale to ease use (43).

FIGURE 1
www.frontiersin.org

Figure 1. Visualization of LEFS data. Score distribution by histogram (top) and boxplot with maximum, minimum, interquartile range and median values (bottom).

Gait and LEFS data were analyzed on the participant level if both records could be obtained within a one week window to ensure appropriate temporal alignment. This accounted for variation in timing of app usage. When multiple ambulatory sessions met this criterion, only the earliest instance was included to minimize confounding factors from recovery over time and walking bouts were truncated at 60 s to avoid potential effects of fatigue. Due to the proprietary and sensitive health-related nature of the data source, there was limited personal information available to the study team (e.g., 48% of the sample were missing gender identifiers since this was not a required field for enrollment with OneStep services) so these characteristics were not incorporated into the analysis. Unilateral outputs (ie. stance, step length) were specified as high or low after comparison. Given the mixed clinical sample and variability in dominance patterns (i.e., the weaker or post-surgical limb may not always present as such), this simple convention by relative magnitude of values was chosen to avoid over-interpreting results.

Descriptive statistics were reported on all spatiotemporal parameters. Distributions were examined for normality using histograms and Q-Q plots. Continuous and categorical metrics are presented as mean (standard deviation) and count (frequency/percentage), respectively. Hypothesis tests were two-tailed with p < .05 considered statistically significant. This being an exploratory investigation, average standardized mean difference (aSMD) was used as the measure of magnitude between groups to provide an overall estimate (Cohen's d for each unique comparisons of “Low”, “Medium”, and “High” LEFS categories); effect sizes were classified as Small (0.2–0.5), Medium (0.5–0.8), and Large (≥0.8) (46). Due to multiplicity concerns, all p-values were adjusted using the Benjamini-Hochberg false discovery rate procedure since Bonferroni correction is too conservative if many tests are performed (47). For estimating how gait variables differ across LEFS mobility categories, the One-Way Analysis of Variance (ANOVA) or Kruskal Wallis One-Way ANOVA (KW-ANOVA) was used, according to normality. The non-normally distributed outcomes analyzed by KW-ANOVA were cadence variability, double support time and each asymmetry measure (stance, double support, step length). Only means (standard deviation) are presented for consistency. Analyses were performed in R software v4.0.2 (R Foundation for Statistical Computing, Vienna, Austria) (48, 49) with the following packages: “tableone” (50), “lubridate” (51), “summarytools” (52), “Hmisc” (53), and “tidyverse” (54).

3. Results

There were 132 OneStep users included in this analysis. From the available data for gender (n = 87, 65.9%), females represented 74.7%. Age was recorded in 43.2% cases (n = 57), comprising as follows: 8.8% less than 30 years old, 17.5% 30 to 45, 5.3% 45 to 60 and 68.4% over 60 years old. A diagnosis was known for 63.6% (n = 84) of the sample. The highest share were post-surgical, presenting with total hip replacement (n = 33, 39.3%), total knee replacement (n = 18, 21.4%) or both (n = 3, 3.6%). Another 29.8% (n = 25) had an orthopedic condition (i.e., musculoskeletal pain/injury) affecting the lower body and 6.0% (n = 5) could be classified as neurological. Overall, the mean LEFS score was 48.2 (17.9) with an even distribution across functional categories of Low (0–40, n = 44, 33.3%), Medium (41–60, n = 49, 37.1%) and High (61–80, n = 39, 29.6%) (Figure 1). As shown in Table 1, the largest observed effect size was from velocity (aSMD = 1.044), followed by cadence (aSMD = 0.971), step length-low (aSMD = 0.888) and stride length (aSMD = 0.886). Most of the spatiotemporal variables had medium to large effect sizes; 5 of the 14 examined (35.7%) were small: cadence variability, base width, step length asymmetry, stance asymmetry, and double support asymmetry. The ANOVA analyses found significant differences between LEFS groups after Bejamini-Hochberg correction for all outcomes except cadence variability, base width, and stance asymmetry (Table 2). Means were significantly larger for cadence, velocity, stride length, hip range and step lengths in the High LEFS category while the Low group had higher stance times, double support and asymmetry measures (step length, double support).

TABLE 1
www.frontiersin.org

Table 1. Spatiotemporal variables and zero-order effects between categories of LEFS.

TABLE 2
www.frontiersin.org

Table 2. Analysis of variance across LEFS groups.

4. Discussion

The results of this cross-sectional retrospective analysis suggest that remotely-collected gait metrics are significantly associated with subjects’ category of function based on LEFS scores. While the relationship between objective outcomes and self-assessment measures of lower extremity performance has previously been investigated, to our knowledge no other studies have incorporated spatiotemporal parameters from mobile devices obtained outside the clinic or laboratory setting for this purpose. Mobility level classification (Low, Medium, High) according to the LEFS is also a novel approach, but the cut-off values chosen should be validated through prospective trial design. As a proof-of-concept, clinically-relevant data in various forms (i.e., kinematics, questionnaire) can be captured via (OneStep) smartphone application on a relatively large scale. These findings may have practical informative value for the (tele)rehabilitation context, owing to the substantial sample size and broad inclusion criteria. Engagement with e-health technologies by older adults is encouraging for increased uptake and acceptance to access purported benefits (55). Yet, the lack of specific clinical characteristics to examine as influencing factors greatly limits a multivariate approach and precise interpretation about the effects observed. This study could be less applicable to neurological conditions, which were underrepresented in the user cohort. Further work is needed to determine whether this convergent validity holds in specific situations (e.g., recovery stage, level of severity). Age and surgical history were shown to impact LEFS scores in a healthy reference population (45), though only modestly compared with the magnitudes of difference between groups seen here. By calculated aSMD, velocity was the strongest predictor for functional categorization, like an earlier report similarly demonstrated using another subjective tool (28) and in line with the significant body of literature on this robust metric (3). A possible explanation is that patients seem to interpret difficulty as time to complete a task along with pain and exertion (36), which plausibly affect the speed of an activity too. Weaker associations were found for the asymmetry variables, suggesting certain aspects of movement quality are not considered very important in self-evaluation, despite therapy programs commonly addressing unilateral impairment (e.g., hip/knee arthroplasty or post-stroke hemiplegia). Because interlimb imbalances have potential negative consequences (56), accurate detection provides additional insights for condition management; however, focusing on more easily observable biomechanical features (i.e., cadence, stride length) may confer a greater sense of functional ability. Symmetry metrics are also relevant to higher level tasks that challenge stability (e.g., single leg stance) so other perceptive domains such as balance confidence could be interesting to investigate.

Understanding the basis of individual perceptions can be particularly valuable when change is tracked over time. It is unclear whether the LEFS and walking measurements would continue to relate longitudinally since responsiveness may differ between outcomes (30, 57, 58). Therefore, collecting data to address multiple domains of physical performance remains appropriate for a comprehensive impression about recovery, which aligns with current research and clinical practice recommendations (26, 27). To efficiently streamline workflows or protocols though, individual measures should be compared since redundancies in analytic value potentially exist. The formation of patient subgroups has plausible utility as well, perhaps in order to adapt care accordingly and triage when resources are limited, considering prior evidence that post-operative improvements depend on self-reported function (59). Higher LEFS scores may indicate less progress will be achieved throughout rehabilitation due to possible ceiling effects and physiological adaptation constraints. Expectation and other cognitive components are also likely important factors. In this case, clinicians could incorporate supplemental standardized tests or quantitative gait analysis revealing residual impairments for a more sensitive metric of treatment efficacy and to support decision-making when targeted interventions are applied. Additional insights might be gained from obtaining information about daily life activity if an individuals' own evaluation does not reflect actual behavior. Ecologically valid task items and parameters are necessary to determine whether there is a performance gap between hypothetical capacity and enacted function in “real world” environments. Future research to explore how objective and subjective assessment methods each operate in specific contexts or under particular conditions will be facilitated by remote monitoring technology like the OneStep application for optimal usage of these separate but associated tools within the evolving telehealth care system.

Data availability statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.

Ethics statement

Ethical review and approval was not required for the study on human participants in accordance with the local legislation and institutional requirements. Written informed consent for participation was not required for this study in accordance with the national legislation and the institutional requirements.

Author contributions

All authors contributed to the article and approved the submitted version.

Funding

This work was supported by Celloscope Inc. Study sponsors were involved in data collection; all other aspects of manuscript preparation (analysis and interpretation of data, writing, decision to submit for publication) were independently performed by the authors.

Conflict of interest

This work was supported by Celloscope Inc. Study sponsors were involved in data collection.

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Baker R. Gait analysis methods in rehabilitation. J Neuroeng Rehabil. (2006) 3(1):4. doi: 10.1186/1743-0003-3-4

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Fritz S, Lusardi M. White paper: “walking speed: the sixth vital sign”. J Geriatr Phys Ther. (2009) 32(2):46–9. doi: 10.1519/00139143-200932020-00002

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Middleton A, Fritz SL, Lusardi M. Walking speed: the functional vital sign. J Aging Phys Act. (2015) 23(2):314–22. doi: 10.1123/japa.2013-0236

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Brown RT, Diaz-Ramirez LG, Boscardin WJ, Lee SJ, Steinman MA. Functional impairment and decline in middle age: a cohort study. Ann Intern Med. (2017) 167(11):761. doi: 10.7326/M17-0496

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Glass TA. Conjugating the “tenses” of function: discordance among hypothetical, experimental, and enacted function in older adults. Gerontologist. (1998) 38(1):101–12. doi: 10.1093/geront/38.1.101

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Baker R, Esquenazi A, Benedetti MG, Desloovere K. Gait analysis: clinical facts. Eur J Phys Rehabil Med. (2016) 52(4):560–74.27618499

PubMed Abstract | Google Scholar

7. Viteckova S, Kutilek P, Svoboda Z, Krupicka R, Kauler J, Szabo Z. Gait symmetry measures: a review of current and prospective methods. Biomed Signal Process Control. (2018) 42:89–100. doi: 10.1016/j.bspc.2018.01.013

CrossRef Full Text | Google Scholar

8. Porciuncula F, Roto AV, Kumar D, Davis I, Roy S, Walsh CJ, et al. Wearable movement sensors for rehabilitation: a focused review of technological and clinical advances. PM&R. (2018) 10(9S2):S220–32. doi: 10.1016/j.pmrj.2018.06.013

CrossRef Full Text | Google Scholar

9. Dobkin BH, Martinez C. Wearable sensors to monitor, enable feedback, and measure outcomes of activity and practice. Curr Neurol Neurosci Rep. (2018) 18(12):87. doi: 10.1007/s11910-018-0896-5

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Rast FM, Labruyère R. Systematic review on the application of wearable inertial sensors to quantify everyday life motor activity in people with mobility impairments. J Neuroeng Rehabil. (2020) 17(1):148. doi: 10.1186/s12984-020-00779-y

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Picerno P, Iosa M, D’Souza C, Benedetti MG, Paolucci S, Morone G. Wearable inertial sensors for human movement analysis: a five-year update. Expert Rev Med Devices. (2021) 18(Supp1):79–94. doi: 10.1080/17434440.2021.1988849

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Wang X, Yu H, Kold S, Rahbek O, Bai S. Wearable sensors for activity monitoring and motion control: a review. Biomim Intell Robot. (2023) 3(1):100089. doi: 10.1016/j.birob.2023.100089

CrossRef Full Text | Google Scholar

13. Caldas R, Mundt M, Potthast W, Buarque De Lima Neto F, Markert B. A systematic review of gait analysis methods based on inertial sensors and adaptive algorithms. Gait Posture. (2017) 57:204–10. doi: 10.1016/j.gaitpost.2017.06.019

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Silsupadol P, Teja K, Lugade V. Reliability and validity of a smartphone-based assessment of gait parameters across walking speed and smartphone locations: body, bag, belt, hand, and pocket. Gait Posture. (2017) 58:516–22. doi: 10.1016/j.gaitpost.2017.09.030

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Kobsar D, Charlton JM, Tse CTF, Esculier JF, Graffos A, Krowchuk NM, et al. Validity and reliability of wearable inertial sensors in healthy adult walking: a systematic review and meta-analysis. J NeuroEngineering Rehabil. (2020) 17(1):62. doi: 10.1186/s12984-020-00685-3

CrossRef Full Text | Google Scholar

16. Rashid U, Barbado D, Olsen S, Alder G, Elvira JLL, Lord S, et al. Validity and reliability of a smartphone app for gait and balance assessment. Sensors. (2021) 22(1):124. doi: 10.3390/s22010124

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Kahlon A, Sansare A, Behboodi A. Remote gait analysis as a proxy for traditional gait laboratories: utilizing smartphones for subject-driven gait assessment across differing terrains. Biomechanics. (2022) 2(2):235–54. doi: 10.3390/biomechanics2020019

CrossRef Full Text | Google Scholar

18. McCambridge J, Witton J, Elbourne DR. Systematic review of the Hawthorne effect: new concepts are needed to study research participation effects. J Clin Epidemiol. (2014) 67(3):267–77. doi: 10.1016/j.jclinepi.2013.08.015

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Manor B, Yu W, Zhu H, Harrison R, Lo OY, Lipsitz L, et al. Smartphone app–based assessment of gait during normal and dual-task walking: demonstration of validity and reliability. JMIR MHealth UHealth. (2018) 6(1):e36. doi: 10.2196/mhealth.8815

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Reginya S, Meigal AY, Gerasimova-Meigal LI, Prokhorov K, Moschevikin A. Using smartphone inertial measurement unit for analysis of human gait. Int J Embed Real-Time Commun Syst. (2019) 10(3):101–17. doi: 10.4018/IJERTCS.2019070107

CrossRef Full Text | Google Scholar

21. Liu X, Zhao C, Zheng B, Guo Q, Duan X, Wulamu A, et al. Wearable devices for gait analysis in intelligent healthcare. Front Comput Sci. (2021) 3:661676. doi: 10.3389/fcomp.2021.661676

CrossRef Full Text | Google Scholar

22. Abou L, Peters J, Wong E, Akers R, Dossou MS, Sosnoff JJ, et al. Gait and balance assessments using smartphone applications in Parkinson’s disease: a systematic review. J Med Syst. (2021) 45(9):87. doi: 10.1007/s10916-021-01760-5

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Abou L, Wong E, Peters J, Dossou MS, Sosnoff JJ, Rice LA. Smartphone applications to assess gait and postural control in people with multiple sclerosis: a systematic review. Mult Scler Relat Disord. (2021) 51:102943. doi: 10.1016/j.msard.2021.102943

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Meigal AY, Gerasimova-Meigal LI, Reginya SA, Soloviev AV, Moschevikin AP. Gait characteristics analyzed with smartphone IMU sensors in subjects with parkinsonism under the conditions of “dry” immersion. Sensors. (2022) 22(20):7915. doi: 10.3390/s22207915

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Peters J, Abou L, Wong E, Dossou MS, Sosnoff JJ, Rice LA. Smartphone-based gait and balance assessment in survivors of stroke: a systematic review. Disabil Rehabil Assist Technol. (2022):1–11. doi: 10.1080/17483107.2022.2072527

CrossRef Full Text | Google Scholar

26. Bellamy N, Kirwan J, Boers M, Brooks P, Strand V, Tugwell P, et al. Recommendations for a core set of outcome measures for future phase III clinical trials in knee, hip, and hand osteoarthritis. Consensus development at OMERACT III. J Rheumatol. (1997) 24(4):799–802.9101522

PubMed Abstract | Google Scholar

27. Ashford S, Brown S, Turner-Stokes L. Systematic review of patient-reported outcome measures for functional performance in the lower limb. J Rehabil Med. (2015) 47(1):9–17. doi: 10.2340/16501977-1889

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Cress ME, Schechtman KB, Mulrow CD, Fiatarone MA, Gerety MB, Buchner DM. Relationship between physical performance and self-perceived physical function. J Am Geriatr Soc. (1995) 43(2):93–101. doi: 10.1111/j.1532-5415.1995.tb06372.x

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Hoeymans N, Feskens EJM, van den Bos GAM, Kromhout D. Measuring functional status: cross-sectional and longitudinal associations between performance and self-report (Zutphen Elderly Study 1990–1993). J Clin Epidemiol. (1996) 49(10):1103–10. doi: 10.1016/0895-4356(96)00210-7

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Bily W, Jauker J, Nics H, Grote V, Pirchl M, Fischer MJ. Associations between patient-reported and clinician-reported outcome measures in patients after traumatic injuries of the lower limb. Int J Environ Res Public Health. (2022) 19(5):3140. doi: 10.3390/ijerph19053140

PubMed Abstract | CrossRef Full Text | Google Scholar

31. Mizner RL, Petterson SC, Clements KE, Zeni JA, Irrgang JJ, Snyder-Mackler L. Measuring functional improvement after total knee arthroplasty requires both performance-based and patient-report assessments. J Arthroplasty. (2011) 26(5):728–37. doi: 10.1016/j.arth.2010.06.004

PubMed Abstract | CrossRef Full Text | Google Scholar

32. Poitras S, Wood KS, Savard J, Dervin GF, Beaulé PE. Assessing functional recovery shortly after knee or hip arthroplasty: a comparison of the clinimetric properties of four tools. BMC Musculoskelet Disord. (2016) 17(1):478. doi: 10.1186/s12891-016-1338-7

PubMed Abstract | CrossRef Full Text | Google Scholar

33. Jacobs CA, Christensen CP. Correlations between knee society function scores and functional force measures. Clin Orthop. (2009) 467(9):2414–9. doi: 10.1007/s11999-009-0811-0

PubMed Abstract | CrossRef Full Text | Google Scholar

34. Binkley JM, Stratford PW, Lott SA, Riddle DL. The lower extremity functional scale (LEFS): scale development, measurement properties, and clinical application. Phys Ther. (1999) 79(4):371–83. doi: 10.1093/ptj/79.4.371

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Mehta SP, Fulton A, Quach C, Thistle M, Toledo C, Evans NA. Measurement properties of the lower extremity functional scale: a systematic review. J Orthop Sports Phys Ther. (2016) 46(3):200–16. doi: 10.2519/jospt.2016.6165

PubMed Abstract | CrossRef Full Text | Google Scholar

36. Stratford PW, Kennedy D, Pagura SMC, Gollish JD. The relationship between self-report and performance-related measures: questioning the content validity of timed tests. Arthritis Rheum. (2003) 49(4):535–40. doi: 10.1002/art.11196

PubMed Abstract | CrossRef Full Text | Google Scholar

37. Stratford PW, Kennedy DM, Maly MR, MacIntyre NJ. Quantifying self-report measures’ overestimation of mobility scores postarthroplasty. Phys Ther. (2010) 90(9):1288–96. doi: 10.2522/ptj.20100058

PubMed Abstract | CrossRef Full Text | Google Scholar

38. Stratford P, Kennedy D, Clarke H. Confounding pain and function: the WOMAC’s failure to accurately predict lower extremity function. Arthroplasty Today. (2018) 4(4):488–92. doi: 10.1016/j.artd.2018.09.003

PubMed Abstract | CrossRef Full Text | Google Scholar

39. Youn IH, Leutzinger T, Youn JH, Zeni JA, Knarr BA. Self-reported and performance-based outcome measures estimation using wearables after unilateral total knee arthroplasty. Front Sports Act Living. (2020) 2:569932. doi: 10.3389/fspor.2020.569932

PubMed Abstract | CrossRef Full Text | Google Scholar

40. Shahar RT, Agmon M. Gait analysis using accelerometry data from a single smartphone: agreement and consistency between a smartphone application and gold-standard gait analysis system. Sensors. (2021) 21(22):7497. doi: 10.3390/s21227497

PubMed Abstract | CrossRef Full Text | Google Scholar

41. Shema-Shiratzky S, Beer Y, Mor A, Elbaz A. Smartphone-based inertial sensors technology—validation of a new application to measure spatiotemporal gait metrics. Gait Posture. (2022) 93:102–6. doi: 10.1016/j.gaitpost.2022.01.024

PubMed Abstract | CrossRef Full Text | Google Scholar

42. Christensen JC, Stanley EC, Oro EG, Carlson HB, Naveh YY, Shalita R, et al. The validity and reliability of the OneStep smartphone application under various gait conditions in healthy adults with feasibility in clinical practice. J Orthop Surg. (2022) 17(1):417. doi: 10.1186/s13018-022-03300-4

CrossRef Full Text | Google Scholar

43. Wang YC, Hart DL, Stratford PW, Mioduski JE. Clinical interpretation of a lower-extremity functional scale–derived computerized adaptive test. Phys Ther. (2009) 89(9):957–68. doi: 10.2522/ptj.20080359

PubMed Abstract | CrossRef Full Text | Google Scholar

44. Jette A, Tao W, Norweg A, Haley S. Interpreting rehabilitation outcome measurements. J Rehabil Med. (2007) 39(8):585–90. doi: 10.2340/16501977-0119

PubMed Abstract | CrossRef Full Text | Google Scholar

45. Dingemans SA, Kleipool SC, Mulders MAM, Winkelhagen J, Schep NWL, Goslings JC, et al. Normative data for the lower extremity functional scale (LEFS). Acta Orthop. (2017) 88(4):422–6. doi: 10.1080/17453674.2017.1309886

PubMed Abstract | CrossRef Full Text | Google Scholar

46. Cohen J. Statistical Power Analysis for the Behavioral Sciences. 0 ed. Routledge. (2013). Available from: https://www.taylorfrancis.com/books/9781134742707 (Cited 2023 May 5).

47. Barton M, Yeatts PE, Henson RK, Martin SB. Moving beyond univariate post-hoc testing in exercise science: a primer on descriptive discriminate analysis. Res Q Exerc Sport. (2016) 87(4):365–75. doi: 10.1080/02701367.2016.1213352

PubMed Abstract | CrossRef Full Text | Google Scholar

48. R Development Core Team. A language and environment for statistical computing: Reference index. Vienna: R Foundation for Statistical Computing (2020). Available from: http://www.polsci.wvu.edu/duval/PS603/Notes/R/fullrefman.pdf (Cited 2022 Apr 15).

49. Liang J, Bi G, Zhan C. Multinomial and ordinal logistic regression analyses with multi-categorical variables using R. Ann Transl Med. (2020) 8(16):982. doi: 10.21037/atm-2020-57

PubMed Abstract | CrossRef Full Text | Google Scholar

50. Yoshida K, Bartel A. Tableone: Create Table 1’ to Describe baseline characteristics with or without propensity score weights. (2021). Available from: https://github.com/kaz-yos/tableone

51. Grolemund G, Wickham H. Dates and times made easy with lubridate. J Stat Softw. (2011) 40(3):1–25. doi: 10.18637/jss.v040.i03

CrossRef Full Text | Google Scholar

52. Comtois D. Tools to Quickly and Neatly Summarize Data. (2021). Available from: https://github.com/dcomtois/summarytools

53. Harrell FE Jr. Hmisc: Harrell Miscellaneous. (2021). Available from: https://hbiostat.org/R/Hmisc/

54. Wickham H, Averick M, Bryan J, Chang W, McGowan L, François R, et al. Welcome to the Tidyverse. J Open Source Softw. (2019) 4(43):1686. doi: 10.21105/joss.01686

CrossRef Full Text | Google Scholar

55. Wilson J, Heinsch M, Betts D, Booth D, Kay-Lambkin F. Barriers and facilitators to the use of e-health by older adults: a scoping review. BMC Public Health. (2021) 21(1):1556. doi: 10.1186/s12889-021-11623-w

PubMed Abstract | CrossRef Full Text | Google Scholar

56. Bautmans I, Jansen B, Van Keymolen B, Mets T. Reliability and clinical correlates of 3D-accelerometry based gait analysis outcomes according to age and fall-risk. Gait Posture. (2011) 33(3):366–72. doi: 10.1016/j.gaitpost.2010.12.003

PubMed Abstract | CrossRef Full Text | Google Scholar

57. Kluge F, Hannink J, Pasluosta C, Klucken J, Gaßner H, Gelse K, et al. Pre-operative sensor-based gait parameters predict functional outcome after total knee arthroplasty. Gait Posture. (2018) 66:194–200. doi: 10.1016/j.gaitpost.2018.08.026

PubMed Abstract | CrossRef Full Text | Google Scholar

58. Bolink SAAN, Grimm B, Heyligers IC. Patient-reported outcome measures versus inertial performance-based outcome measures: a prospective study in patients undergoing primary total knee arthroplasty. Knee. (2015) 22(6):618–23. doi: 10.1016/j.knee.2015.04.002

PubMed Abstract | CrossRef Full Text | Google Scholar

59. Bolink SAAN, Lenguerrand E, Brunton LR, Wylde V, Gooberman-Hill R, Heyligers IC, et al. Assessment of physical function following total hip arthroplasty: inertial sensor based gait analysis is supplementary to patient-reported outcome measures. Clin Biomech. (2016) 32:171–9. doi: 10.1016/j.clinbiomech.2015.11.014

CrossRef Full Text | Google Scholar

Keywords: mHealth, gait analysis, subjective function, rehabilitation technology, remote patient monitoring

Citation: Rozanski G, Delgado A and Putrino D (2023) Spatiotemporal parameters from remote smartphone-based gait analysis are associated with lower extremity functional scale categories. Front. Rehabil. Sci. 4:1189376. doi: 10.3389/fresc.2023.1189376

Received: 21 March 2023; Accepted: 12 July 2023;
Published: 26 July 2023.

Edited by:

Ryan Thomas Roemmich, Kennedy Krieger Institute, United States

Reviewed by:

Chris Awai Easthope, Cereneo Foundation, Switzerland
Elke Warmerdam, Saarland University, Germany
Libak Abou, University of Michigan, United States

© 2023 Rozanski, Delgado and Putrino. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Gabriela Rozanski gabriela.rozanski@mountsinai.org

ORCID Andrew Delgado orcid.org/0000-0001-5675-4096

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.