Skip to main content

ORIGINAL RESEARCH article

Front. Public Health, 10 August 2021
Sec. Infectious Diseases – Surveillance, Prevention and Treatment
This article is part of the Research Topic Emerging Infectious and Vector-Borne Diseases: A Global Challenge, Volume II View all 6 articles

Comparison of the Efficacy of Disinfectant Pre-impregnated Wipes for Decontaminating Stainless Steel Carriers Experimentally Inoculated With Ebola Virus and Vesicular Stomatitis Virus

\nTodd A. Cutts,Todd A. Cutts1,2Samantha B. Kasloff,Samantha B. Kasloff1,2Jay Krishnan,Jay Krishnan1,2Raymond W. NimsRaymond W. Nims3Steven S. TheriaultSteven S. Theriault4Joseph R. RubinoJoseph R. Rubino5M. Khalid Ijaz,
M. Khalid Ijaz5,6*
  • 1Canadian Science Centre for Human and Animal Health, Winnipeg, MB, Canada
  • 2J.C. Wilt Infectious Diseases Research Centre, Public Health Agency of Canada, Winnipeg, MB, Canada
  • 3RMC Pharmaceutical Solutions, Inc., Longmont, CO, United States
  • 4Department of Microbiology, The University of Manitoba, Winnipeg, MB, Canada
  • 5Reckitt Benckiser LLC, Global Research & Development for Lysol and Dettol, Montvale, NJ, United States
  • 6Department of Biology, Medgar Evers College of the City University of New York (CUNY), Brooklyn, NY, United States

The authors evaluated four disinfectant pre-impregnated wipes (DPW) for efficacy against Ebola virus Makona variant (EBOV) and vesicular stomatitis virus (VSV), Indiana serotype. Steel carriers were inoculated with the infectious virus and then were wiped with DPW in the Wiperator instrument per ASTM E2967-15. Following the use of J-Cloth impregnated with medium (negative control wipes) or the use of activated hydrogen peroxide (AHP)-, ethanol-, sodium hypochlorite (NaOCl)-, or single or dual quaternary ammonium compound (QAC)-based DPW, virus recovery from the carriers was assayed by titration assay and by two passages on Vero E6 cells in 6-well plates. The Wiperator also enabled the measurement of potential transfer of the virus from the inoculated carrier to a secondary carrier by the DPW or control wipes. The J-Cloth wipes wetted with medium alone (no microbicidal active) removed 1.9–3.5 log10 of virus from inoculated carriers but transferred ~4 log10 of the wiped virus to secondary carriers. DPW containing AHP, ethanol, NaOCl, or single or dual QAC as active microbicidal ingredients removed/inactivated ~6 log10 of the virus, with minimal EBOV or no VSV virus transfer to a secondary surface observed. In Ebola virus outbreaks, a DPW with demonstrated virucidal efficacy, used as directed, may help to mitigate the unintended spread of the infectious virus while performing surface cleaning.

Introduction

Disinfectant pre-impregnated wipes (DPW) are an optional intervention for disrupting the cycle of infection transmission since these wipes may remove and inactivate pathogens from contaminated high-touch environmental surfaces (HITES) during use (1). Sattar and Maillard (2) correctly used the term decontamination to encompass both the physical removal and the inactivation functions of such wipes. As it is not always easy to dissect out the contributions of these two functions, decontamination seems an apt term for quantifying the net decrease in the number of infectious viruses on a cleaned surface following the use of such a wipe. As demonstrated previously (27), a wipe that is not impregnated with an effective disinfectant may provide physical removal only. Such a wipe, once used, may spread pathogens from a wiped contaminated surface to a secondary non-contaminated surface. For this reason, wipes that do not contain a microbicidal activity with sufficient efficacy against the target pathogen should not represent an effective intervention for limiting the spread of an infectious agent caused by indirect transmission from contaminated HITES.

We have characterized the removal, transfer, and inactivation of infectious Ebola virus Makona variant (EBOV) or vesicular stomatitis virus (VSV) by a control wipe and two DPW wipes from stainless steel carriers experimentally contaminated with the viruses in a previous study (7). Our intent in that study was to quantify the potential for transfer of infectious virus from one surface to another through the use of cleaning wipes that have no microbicidal activity (negative control wipe) or two DPW having activities with varying efficacy for the target virus. In that study, we made no conclusions regarding the relative efficacy of the two DPW for inactivating EBOV or VSV. The potential transfer of virus from a primary wiped surface to a secondary wiped surface as a result of incomplete inactivation of a virus absorbed onto a cleaning wipe is of concern, as this may represent a source of ongoing transmission of that virus.

In this study, we have used the standard testing method, ASTM E2967-15 (8), involving the Wiperator device (810), to evaluate the comparative efficacy of wipes containing no microbicidal active and wipes impregnated with a variety of disinfectants for decontamination of steel carriers (prototypic HITES) experimentally contaminated with a virus. We used, as challenge viruses, fully pathogenic EBOV or VSV. VSV was included, as this virus has been used previously as a surrogate for the Ebola virus [e.g., (11)]. Both are enveloped viruses. Ebola virus is a large (80 × 14,000 nm), cylindrical, negative single-stranded RNA virus of the Filoviridae family (12). VSV is also a large (70 × 170 nm), bullet-shaped, negative single-stranded RNA virus (13). The experimental design of the studies performed went beyond the ASTM method to include the passage of undiluted post-neutralization samples in 6-well plates of Vero E6 cells. This additional step was expected to increase the overall sensitivity of the assay for detecting any residual infectious virus following wiping.

Materials and Methods

Cell Line, Viruses, and Medium

African green monkey Vero E6 cells (ATCC CRL-1586; American Type Culture Collection, Manassas, VA, US) were incubated at 37°C/5% CO2 in DMEM (HyClone, Logan, UT, US) containing 10% fetal bovine serum (FBS; Gibco, Grand Island, NY, United States) and 10 units/mL penicillin/streptomycin (Gibco). EBOV (Ebola virus/H. sapiens-tc/GIN/2014/Makona-C05; GenBank accession no. KJ660348) was obtained from a clinical isolate. The virus was subsequently engineered to express a green fluorescent protein (GFP). A stock of VSV, Indiana serotype, was prepared from a reverse genetics construct (14, 15) engineered to express GFP. The virus stocks were prepared by infecting Vero E6 cells, as described in Cutts et al. (7), and were titered on the basis of the viral cytopathic effect (CPE). Titers of the stocks were determined by the Reed-Muench procedure (16) to be ≥8.8 log10 TCID50/ml.

Negative Control J-Cloth Wipes

The negative control wipe used in this study was the “J-Cloth,” a representative material composed of cellulosic fibers from wood pulp that has been used earlier in studies of this type (8, 10). The J-Cloth contained no microbicidal activity. The sterile J-Cloth (4 × 4 cm) wipes were prepared as described previously (7).

Preparation of DPW for Viral Decontamination Efficacy Studies

“AHP wipes” were prepared by impregnating sterile J-Cloth wipes with a 1:40 solution of accelerated hydrogen peroxide (AHP; PreEmpt, Virox Technologies, Inc., Oakville, ON, Canada), as described previously (7). “Single QAC wipes” consisted of a ready-to-use commercially available wipe composed of cellulosic pulp and polypropylene impregnated with a quaternary ammonium compound (QAC: benzyl-C12-16-alkyldimethyl chloride; Lysol Wipes; Reckitt Benckiser LLC, Montvale, NJ, United States). The three single QAC wipe lots were tested near the end of their stated expiry dates. “Dual QAC wipes” consisted of J-Cloth squares impregnated with a 1:20 solution of MicroChem (National Chemical Laboratories, Philadelphia, PA, US; lot c22c1, other lot numbers not recorded) in hard water. “Ethanol wipes” consisted of J-Cloth squares impregnated with a 66.5% ethanol solution (Commercial Alcohols, Toronto, ON, Canada; lots 029073, 026796, and 028309) in hard water. “NaOCl wipes” consisted of J-Cloth squares impregnated with a 1% NaOCl solution (Imperial Hand Sanitizer; IMP750-1; Winnipeg, MB, Canada; lot numbers not recorded). Neutralization of the disinfectants following the use of DPW was performed using neutralizers qualified for use as described in Supplementary Materials.

Decontamination Efficacy Testing of Wipes

The testing of wipes for the ability to decontaminate a prototype environmental surface (stainless steel carriers) was performed as per ASTM 2967-15 (8). EBOV and VSV inocula were prepared in a tripartite soil load (17, 18). In the standard, the term “soil load” is intended to denote a matrix used to challenge the inactivation/removal (decontamination) of the test virus. The term “organic load” is considered equivalent to “soil load,” although the former term is more descriptive of the typical challenge matrix (secretions/excretions within which the virus is released from an infected person). The tripartite soil load consisted of sterile components (12.5 μl of 5% bovine serum albumin + 17.5 μl 5% tryptone + 50 μl 0.4% mucin) added to 170 μl of virus stock. This soil load/virus mixture was prepared fresh daily for each test replicate performed. Using a positive displacement pipette, 10 μl of virus inoculum was deposited onto sterile carriers and air-dried for 60 min in a biological safety cabinet within a BSL-2 (VSV) or BSL-4 (EBOV) laboratory prior to Wiperator (Filtaflex, Almonte, ON, Canada) testing.

Virus-inoculated carriers were placed into a slot on one side of the Wiperator carrier plate (Figure 1, see also Supplementary Figure 1) and were held in place by a magnet on the underside of the plate. A second, non-inoculated, carrier (secondary container) was placed in a second fitted slot on the other side of the carrier plate. Sterile DPW or DMEM-impregnated wipes were removed from the Petri dishes using sterile forceps, loaded onto the Wiperator Boss (Supplementary Figure 1), and held in place with a large O-ring. The loaded Bosses were secured to the Wiperator spindle, and the plates containing the carriers were moved into place. The wiping action was programmed to start as soon as contact was made with the plate. The orbital wiping parameters were 10 mm in diameter, with 150 g of pressure, for 5-, 15-, 30-, or 60-s wiping. The 60-s wiping time, while impractical from an actual cleaning use point of view, allowed us to fully explore the inactivation time kinetics for each DPW. After being wiped, carrier plates were rotated and returned into place, exposing the uninoculated secondary carrier to the used wipe. As before, the wiping started as soon as contact was made with the carrier and continued for 5 s/cycle at 150 g pressure. Carriers were subsequently removed and aseptically transferred into 1 ml of VCM neutralizing solution (DMEM + 2% fetal calf serum + 10 units/mL penicillin/streptomycin). The presence of an infectious virus in an eluted medium from neutralized carriers was quantified by TCID50 assay in a 96-well plate format on Vero E6 cells (see Supplementary Materials for the procedure used). The limit of detection of the titration method for each virus was 1.3 log10 TCID50/mL, the minimum titer that can be calculated in the TCID50 assay employing five replicate wells per titration and in the absence of cytotoxic effects of the neutralized test sample. The plate safety test involved inoculation of 500 μL of undiluted eluate from carriers into 6-well plates of Vero E6 cells. These were monitored for CPE and GFP over 14 days (EBOV) and 4 days (VSV), after which the culture supernatant was harvested and used to inoculate fresh Vero E6 cultures. This was used to ensure that a negative result in the TCID50 assay was truly negative. The limit of detection of the plate safety test was determined to be 1–2 TCID50 per inoculation (see Supplementary Materials).

FIGURE 1
www.frontiersin.org

Figure 1. Schematic representation of the inactivation/removal testing methodology employed.

The evaluation of wipes against EBOV was performed at ambient temperature in a Class II BSC in the BSL-4 laboratories of the Public Health Agency of Canada, at the Canadian Science Center for Human and Animal Health, Winnipeg, MB, which is operated by the Government of Canada. Evaluations for VSV were conducted in a Class II BSC in the JC Wilt Infectious Disease Laboratory.

Results

Disinfectant Neutralizer Effectiveness Testing

The selection of the appropriate neutralizing agent for each disinfectant was informed by the results of testing described in Supplementary Materials.

Disinfectant Efficacy Testing

The results obtained during carrier testing of the control wipes and five different DPW are displayed in Tables 1, 2 for EBOV and Tables 3, 4 for VSV, respectively. Decontamination of the inoculated carriers, representing a combination of removal and inactivation, was calculated as the difference in titer of the virus recovered from the dried untreated control carrier and of that recovered from the inoculated carrier following wiping.

TABLE 1
www.frontiersin.org

Table 1. Efficacy of disinfectant-impregnated wipes (DPW) vs. DMEM-impregnated J-Cloth wipes for removal/inactivation (decontamination) or transfer of EBOV*.

TABLE 2
www.frontiersin.org

Table 2. Plate safety test results for inactivation of EBOV by DPW vs. DMEM-impregnated J-Cloth wipes*.

TABLE 3
www.frontiersin.org

Table 3. Efficacy of DPW vs. DMEM-impregnated J-Cloth wipes for removal/inactivation (decontamination) or transfer of vesicular stomatitis virus (VSV)*.

TABLE 4
www.frontiersin.org

Table 4. Plate safety test results for the inactivation of VSV by DPW vs. DMEM-impregnated J-Cloth wipes*.

In the absence of expected viral inactivation, as in the case of the control wipe, decontamination primarily represents “removal.” The extent of virus “transfer” is expressed as a percentage of the virus on the inoculated carrier that was subsequently recovered from the secondary carrier after the 5-s transfer wiping step. “Inactivation,” in the case of DPW, may be implied, but not quantified, by the reduction of viral recovery from the inoculated carriers following wiping for 5, 15, 30, or 60 s and of viral recovery from the secondary carrier following the 5-s transfer wiping step.

The amount of infectious virus remaining on the wipes themselves was not measured. Complete mass balances for the spiking viruses were, therefore, not obtained. The results of the Wiperator study performed to evaluate the efficacy of DPW for decontaminating EBOV-inoculated carriers and VSV-inoculated carriers are displayed in Tables 1, 3, respectively. The values shown represent the combined data from three trials (three replicates each) utilizing one lot of the AHP wipe and one trial each (three replicates per trial) for three lots of the single QAC wipe and dual QAC, ethanol, and NaOCl wipes. The results of the plate safety test for residual infectious EBOV and VSV are displayed in Tables 2, 4, respectively.

Results for EBOV

Negative Control Wipes

Ebola virus Makona variant titers recovered from the carriers after use of the DMEM-impregnated J-Cloth (control wipe) were 3.1– 4.1 log10 TCID50/mL for the 5-, 15-, 30-, and 60-s wiping times, compared with an initial titer of 6.6 log10 TCID50/mL. The log10 decontamination of EBOV from the inoculated carriers for the various wiping times ranged from 2.5 to 3.5 log10, with minimal increases in the extent of decontamination observed with increasing wiping time (Table 1). In the transfer step, the EBOV titers recovered from the secondary carriers were 2.3–3.9 log10 TCID50/mL following transfer from the inoculated carriers wiped for 5, 15, 30, or 60 s. These results indicate that the J-Cloth wipes impregnated with DMEM removed EBOV from the original contaminated surface while transferring a portion of the infectious virus to the secondary surface.

AHP DPW

Ebola virus Makona variant titers recovered from the inoculated carriers after use of the AHP DPW ranged from 0.20 to 1.1 log10 TCID50/mL; n = 9 replicates/time point) (Table 1). The log10 decontamination of EBOV from the inoculated carriers for the various wiping times ranged from 5.5 to 6.4 log10. The results of the plate safety assay (Table 2) confirmed that five of nine, six of nine, three of nine, and one of nine replicates were positive for residual infectious virus for the 5-, 15-, 30-, and 60-s wiping times, respectively. The EBOV titers recovered from the secondary carriers during the transfer step were 0.9 log10 TCID50/mL and 0.1 log10 TCID50/mL (n = 9 replicates) following transfer from the inoculated carriers wiped for 5 and 30 s, respectively. The virus was transferred from three of the nine replicates of the inoculated carriers wiped for 5 s and from a single replicate of the inoculated carriers wiped for 30 s. No detectable infectious EBOV was transferred from the inoculated carriers wiped for 15 or 60 s.

Single QAC DPW

Ebola virus Makona variant (0.6 and 0.2 log10 TCID50/mL; n = 9 replicates) was recovered from carriers after 5-s and 30-s wiping with the single QAC DPW, respectively (Table 1). The log10 decontamination of EBOV from the inoculated carriers for the various wiping times ranged from 6.0 to 6.6 log10. After 15-s and 60-s wiping, no infectious virus was recovered from the inoculated carriers. The results of the plate safety assay (Table 2) confirmed the positive and negative results. The EBOV titers recovered on the secondary carriers following the transfer step were very low (mean 0.2 log10 TCID50/mL; n = 9 replicates). No infectious EBOV was recovered from the secondary carriers following the transfer from carriers wiped for 15, 30, or 60 s.

Dual QAC DPW, NaOCl DPW, and Ethanol DPW

No infectious EBOV was recovered from carriers after use of the Dual QAC, NaOCl, or ethanol DPW, evaluated after 5−60-s wiping (Table 1). The decontamination of EBOV from the inoculated carriers for the various wiping times ranged from 6.0 to 6.6 log10. The results of the plate safety assay (Table 2) confirmed the absence of infectious virus in these replicates for the dual QAC and ethanol DPW. For the NaOCl DPW, the virus was recovered from two replicates at 5 s and one replicate at 15 s. No infectious EBOV was recovered from secondary carriers during the transfer step from the inoculated carriers wiped for 5, 15, 30, or 60 s.

Results for VSV

Negative Control Wipes

Vesicular stomatitis virus titers recovered from the carriers following wiping with the DMEM-impregnated J-Cloth were 3.3 to 3.9 log10 TCID50/mL for the 5-, 15-, 30-, and 60-s wiping times, compared with an initial titer of 5.8 log10 TCID50/mL. The log10 decontamination of VSV from the inoculated carriers for the various wiping times ranged from 1.9 to 2.5 log10, with minimal increases in the extent of decontamination observed with an increase in the wiping time (Table 3). In the transfer step, the VSV titers recovered from the secondary carriers were 3.3 to 3.8 log10 TCID50/mL following transfer from the inoculated carriers wiped for 5, 15, 30, or 60 s. These results indicate that the J-Cloth wipes impregnated with DMEM removed VSV from the original contaminated surface while transferring a portion of the infectious virus to the secondary surface.

NaOCl DPW

Vesicular stomatitis virus (mean titer 0.20 log10 TCID50/mL; n = 9 replicates) was recovered after use of the NaOCl DPW from one of nine replicates evaluated after 5-s wiping (Table 3), indicating incomplete (5.3 log10) decontamination for this condition. This result was confirmed in the plate safety test (Table 4). No infectious VSV was recovered from secondary containers during the transfer step from the inoculated carriers wiped for 5, 15, 30, or 60 s.

Ethanol DPW

Vesicular stomatitis virus (mean titer 0.9 log10 TCID50/mL; n = 9 replicates) was recovered after use of the ethanol DPW from carriers evaluated after 5-s wiping (Table 3). The log10 decontamination of VSV from the inoculated carriers for the various wiping times ranged from 4.6 to 5.5 log10. The results of the plate safety assay (Table 4) confirmed that four of the nine replicates were positive for residual infectious virus for the 5-s wiping time. No infectious virus was recovered from the inoculated carriers wiped for 15, 30, and 60 s. No infectious VSV was recovered from secondary containers during the transfer step from the inoculated carriers wiped for 5, 15, 30, or 60 s.

AHP DPW, Single QAC DPW, and Dual QAC-DPW

For each of these three DPW, VSV was not able to be recovered from the inoculated carriers after the 5-, 15-, 30-, or 60-s wiping times (Table 3). These results were confirmed by the results of the plate safety test (Table 4). This indicates that these DPW removed or inactivated essentially all of the VSV deposited on the original contaminated surface (6.0 to 6.2 log10 TCID50/mL, estimated on the basis of the value for the dried untreated control carrier). No infectious VSV was recovered from the secondary carriers following transfer from the inoculated carriers wiped for 5, 15, 30, or 60 s.

Discussion

Disposable DPW represent an option for reducing pathogen loads on HITES in healthcare and home settings (1, 19). The two orthogonal functionalities of DPW, removal and inactivation, together have been referred to as “decontamination” by Sattar and Maillard (2), and we have adopted this terminology in the present investigation. The inactivation function of a DPW is determined by the efficacy of the incorporated disinfectant against the target virus. A DPW effective for one enveloped virus should also be effective against other enveloped viruses, per the well-established hierarchy of pathogen susceptibility to microbicides (2023). The inactivation resulting from DPW use may occur within the wipe itself or within the liquid expressed from the wipe during wiping of the original HITES or secondary HITES.

For an emerging virus such as those causing hemorrhagic fever, what level of decontamination efficacy is required? For such viruses, a low level of virus transferred from a contaminated surface to a secondary surface may result in the spread of infection to otherwise healthy individuals coming in contact with contaminated HITES. For instance, the infectious dose for the Ebola virus has been estimated to be 1–10 infectious units (24, 25). If a wipe having no or limited microbicidal activity (such as the DMEM-impregnated J-Cloth wipe used as a negative control in this study) was to be used for cleaning, removal of EBOV would be expected, although the lack of inactivation suggests that a portion of the virus could be spread to another surface during the wiping process (7). The spread of even a low percentage of the removed virus by such a wipe (in our study the control wipe transferred >3.2 log10, equating to ~1500 infectious units) from the contaminated HITES to a new surface could represent a significant opportunity for transmitting infectious Ebola virus.

In the present study, we used the ASTM-2967-15 method to evaluate the efficacy of DPW containing one of five actives (AHP, Single QAC, Dual QAC, NaOCL, and ethanol) against EBOV and VSV. These enveloped viruses were expected to be readily inactivated by each of the formulated actives tested. The comparative efficacy of DPW containing different microbicidal actives for decontaminating prototypic HITES inoculated with Ebola virus or VSV has not previously been explored. Our recent article (7) addressed the risk of transfer of these viruses from the original wiped surface to a secondary surface and did not specifically address comparative decontamination efficacy. Becker et al. (6) evaluated four DPW for inactivating three non-enveloped viruses (adenovirus, simian virus 40, and murine norovirus) using the EN 16615 methodology (26). In that study, only a DPW containing a peracetic acid active was found to cause sufficient inactivation of the three viruses to prevent transfer to secondary surfaces during wiping. The DPW with QAC or 2-propanol as active ingredients were found to transfer one or more of the test viruses. This likely reflects the relatively lesser susceptibility of non-enveloped viruses to certain disinfectants (2024, 27).

In the case of EBOV, the dual QAC DPW and ethanol DPW were the most effective DPW (complete, 6.0 log10 decontamination after wiping times of 5–60 s). The single QAC DPW required 60 s to cause complete decontamination (6.0 to 6.6 log10), while the AHP DPW failed to cause complete decontamination after wiping for up to 60 s. The recovery of infectious EBOV following 30-s wiping with the single QAC DPW, but not following 15-s wiping, was unexpected. This may represent sampling issues (i.e., Poisson distribution) as the titers of the virus approached the limit of detection.

The rhabdovirus VSV was found to be more susceptible to decontamination by the AHP DPW and single QAC DPW than EBOV, while being less susceptible to ethanol DPW. The AHP, single QAC, and dual QAC DPW caused complete inactivation at 5−60-s wiping. The structural differences between filoviruses and rhabdoviruses may play a role in the differences in efficacy observed. For instance, filoviruses have more extended tubular structures (80 × 14,000 nm) (12) whereas rhabdoviruses are described as bullet shaped (70 × 170 nm) (13). The extended tubular shape may predispose the filovirus to interact with the cell membranes in the virus stock and with the components of the organic load employed as part of the challenge virus matrix. Taken together, these data suggest that, during outbreaks involving emerging/re-emerging viruses such as Ebola virus, a DPW with demonstrated virucidal efficacy, used as directed, may prevent unintended spread of the infectious virus while performing cleaning of HITES.

We acknowledge the following limitations to our study, which should be kept in mind when considering these results. First, we evaluated viruses deposited on stainless steel carriers only. There are other prototypic HITES surfaces, such as plastic, tile/ceramic, wood, or laminate counter tops, that could potentially be disinfected using DPW. It may not be appropriate to extrapolate our findings using non-porous stainless steel carriers to each of the other types of HITES surfaces. Second, we were able to evaluate wipes composed of cellulose and cellulose/polypropylene only. There may be DPW composed of other fabric types. Our results using cellulose or cellulose/polypropylene wipes should be extrapolated to DPW composed of other fabric types with caution. Finally, we evaluated two enveloped RNA viruses in this study, as our primary interest was in the Ebola virus and a surrogate, VSV. We did not challenge the DPW with an enveloped DNA virus or with any non-enveloped viruses. We expect that the DPW should have a similar efficacy for any enveloped virus on the basis of the known hierarchy of susceptibility of viruses to microbicidal active ingredients (2224). Efficacy for the relatively less susceptible non-enveloped viruses (2224) should not be inferred from our results.

Conclusion

In this investigation, we have identified differences in decontamination efficacy among five DPW with differing microbicidal actives. The dual QAC DPW and ethanol DPW were the most effective for EBOV, causing 6.0 to 6.6 log10 inactivation. NaOCl DPW and single QAC DPW required 30 s and 60 s, respectively, to cause complete inactivation of EBOV. The AHP DPW did not cause complete decontamination of EBOV after ≤ 60-s wiping. Each of the DPW were effective against VSV, causing complete (5.5 to 6.2 log10) inactivation at 15-, 30-, and 60-s wiping. During outbreaks involving emerging/re-emerging viruses such as Ebola virus, a DPW with demonstrated virucidal efficacy, used as directed, may help to mitigate the unintended spread of the infectious virus while performing cleaning of HITES.

Data Availability Statement

The original contributions presented in the study are included in the article's Supplementary Material, further inquiries can be directed to the Corresponding Author.

Author Contributions

MI, TC, and ST conceived and designed the experiments. RN, MI, and TC analyzed the data. RN, MI, JR, TC, ST, JK, and SK each contributed to the writing of the manuscript. All authors reviewed and approved the manuscript.

Funding

This work was supported and jointly funded by the Public Health Agency of Canada and Reckitt Benckiser LLC. JR and MI are employed by Reckitt Benckiser and TC, SK, and JK are employed by Public Health Agency of Canada. The roles of the funding organizations in the study were as follows: internal approvals were sought for the initiation of the studies and for the manuscript prior to submission.

Conflict of Interest

JR and MI are employed by RB, who also provided partial funding support for this study. RN provided data analysis and manuscript preparation as a paid consultant employed by RMC Pharmaceutical Solutions, Inc.

The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's Note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary Material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fpubh.2021.657443/full#supplementary-material

References

1. Lopez G, Kitajima M, Havas A, Gerba C, Reynolds K. Evaluation of a disinfectant wipe intervention on fomite-to-finger microbial transfer. Appl Environ Microbiol. (2014) 80:3113–8. doi: 10.1128/AEM.04235-13

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Sattar S, Maillard J. The crucial role of wiping in decontamination of high-touch environmental surfaces: review of current status and directions for the future. Am J Infect Control. (2013) 41:S97–104. doi: 10.1016/j.ajic.2012.10.032

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Sattar SA. Promises and pitfalls of recent advances in chemical means of preventing the spread of nosocomial infections by environmental surfaces. Am J Infect Control. (2010) 38:S34. doi: 10.1016/j.ajic.2010.04.207

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Wesgate R, Maillard J. Efficacy of commercially available disinfectant wipes to remove, transfer and kill a surrogate human viral pathogen in vitro. Presented at the UK Healthcare Infection Society, in association with La Société Française d'Hygiène Hospitalière. (2014). Available online at: https://www.trycare.co.uk/files/ww/Cardiff%20University%20-%20Efficacy%20of%20disinfectant%20wipes.pdf

Google Scholar

5. Lei H, Li Y, Xiao S, Yang X, Lin C, Norris S, et al. Logistic growth of a surface contamination network and its role in disease spread. Sci Rpt. (2017) 7:14826. doi: 10.1038/s41598-017-13840-z

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Becker B, Henningsen L, Paulmann D, Bischoff B, Todt D, Steinmann E, et al. Evaluation of the virucidal efficacy of disinfectant wipes with a test method simulating practical conditions. Antimicrob Resist Infect Control. (2019) 8:121. doi: 10.1186/s13756-019-0569-4

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Cutts T, Robertson C, Theriault S, Nims R, Kasloff S, Rubino J, et al. Assessing the contributions of inactivation, removal, and transfer of Ebola virus and vesicular stomatitis virus by disinfectant pre-soaked wipes. Front Pub Health. (2020) 8:183. doi: 10.3389/fpubh.2020.00183

PubMed Abstract | CrossRef Full Text | Google Scholar

8. ASTM International. ASTM E2967-15. Standard Test Method for Assessing the Ability of Pre-wetted Towelettes to Remove and Transfer Bacterial Contamination on Hard, Non-Porous Environmental Surfaces Using the Wiperator. West Conshohocken, PA: ASTM International (2015). Available online at: https://webstore.ansi.org/standards/astm/astme296715

Google Scholar

9. Ramm L, Siani H, Wesgate R, Maillard J. Pathogen transfer and high variability in pathogen removal by detergent wipes. Am J Infect Control. (2015) 43:724–8. doi: 10.1016/j.ajic.2015.03.024

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Sattar S, Bradley C, Kibbee R, Wesgate R, Wilkinson M, Sharpe T, et al. Disinfectant wipes are appropriate to control microbial bioburden from surfaces: use of a new ASTM standard test protocol to demonstrate efficacy. J Hosp Infect. (2015) 91:319–25. doi: 10.1016/j.jhin.2015.08.026

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Nikiforuk A, Cutts T, Theriault S, Cook BW. Challenge of liquid stressed protective materials and environmental persistence of Ebola virus. Sci Rep. (2017) 7:4388 doi: 10.1038/s41598-017-04137-2

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Salata C, Calistri A, Alvisi G, Celestino M, Parolin Palù G. Ebola virus entry: from molecular characterization to drug discovery. Viruses. (2019) 11:274. doi: 10.3390/v11030274

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Acha P, Szyfres B. Vesicular Stomatitis. Zoonoses and Communicable Diseases Common to Man and Animals. 3rd ed. Washington D.C.:Pan American Health Organization. (2003) p. 347–55.

Google Scholar

14. Lawson N, Stillman E, Whitt M, Rose J. Recombinant vesicular stomatitis viruses from DNA. Proc Natl Acad Sci USA. (1995) 92:4477–81. doi: 10.1073/pnas.92.10.4477

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Dalton K, Rose J. Vesicular stomatitis virus glycoprotein containing the entire green fluorescent protein on its cytoplasmic domain is incorporated efficiently into virus particles. Virology. (2001) 279:414–21. doi: 10.1006/viro.2000.0736

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Reed L, Muench H. A simple method of estimating fifty percent endpoints. Am J Hygiene. (1938) 27:493–7. doi: 10.1093/oxfordjournals.aje.a118408

CrossRef Full Text | Google Scholar

17. Sattar S, Ansari S. The fingerpad protocol to assess hygienic hand antiseptics against viruses. J Virol Meth. (2002) 103:171–81. doi: 10.1016/S0166-0934(02)00025-3

PubMed Abstract | CrossRef Full Text | Google Scholar

18. ASTM International. ASTM E1052-11. Standard Test Method to Assess the Activity of Microbicides against Viruses in Suspension. (2011). Available online at: https://www.astm.org/Standards/E1052.htm

Google Scholar

19. Song X, Vossebein L, Zille A. Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review. Antimicrob Resist Infect Control. (2019) 8:139 doi: 10.1186/s13756-019-0595-2

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Klein M, Deforest A. Principles of viral inactivation. In: Block SS, editor. Disinfection, sterilization, and preservation, 3rd edition. Philadelphia: Lea and Febiger (1983). p. 422–34.

Google Scholar

21. Sattar SA. Hierarchy of susceptibility of viruses to environmental surface disinfectants: a predictor of activity against new and emerging viral pathogens. J AOAC Int. (2007) 90:1655–8. doi: 10.1093/jaoac/90.6.1655

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Ijaz M, Rubino J. Should test methods for disinfectants use vertebrate virus dried on carriers to advance virucidal claims? Inf Control Hosp Epidemiol. (2008) 29:192–4. doi: 10.1086/526441

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Ijaz M, Sattar S, Rubino J, Nims R, Gerba C. Combating SARS-CoV-2: leveraging microbicidal experiences with other emerging/re-emerging viruses. Peer J. (2020) 8:e9914. doi: 10.7717/peerj.9914

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Bibby K, Fischer R, Casson L, de Carvalho N, Haas C, Munster V. Disinfection of Ebola virus in sterilized municipal wastewater. PLoS Negl Trop Dis. (2017) 11:e0005299. doi: 10.1371/journal.pntd.0005299

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Franz D, Jahrling P, Friedlander A, McClain D, Hoover D, Byrne W, et al. Clinical recognition and management of patients exposed to biological warfare agents. J Am Med Assoc. (1997) 278:399–411.

PubMed Abstract | Google Scholar

26. CEN-Comité Europeen de Normalisation. EN 16615:2015 Chemical disinfectants and antiseptics – quantitative test method for the evaluation of bactericidal and yeasticidal activity on non-porous surfaces with mechanical action employing wipes in the medical area (4-field test) – test method and requirements (phase 2, step 2). (2015). Available online at: https://infostore.saiglobal.com/en-us/Standards/EN-16615-2015-340824_SAIG_CEN_CEN_780961/

Google Scholar

27. International Conference on Harmonisation. ICH Topic Q5A(R1). Viral safety evaluation of biotechnology products derived from cell lines of human or animal origin. (1999). Available online at: https://www.ema.europa.eu/en/ich-q5a-r1-quality-biotechnological-products-viral-safety-evaluation-biotechnology-products-derived

Google Scholar

Keywords: ASTM E2967-15, disinfectant pre-impregnated wipes, Ebola virus Makona variant, viral removal/inactivation, vesicular stomatitis virus, wiperator

Citation: Cutts TA, Kasloff SB, Krishnan J, Nims RW, Theriault SS, Rubino JR and Ijaz MK (2021) Comparison of the Efficacy of Disinfectant Pre-impregnated Wipes for Decontaminating Stainless Steel Carriers Experimentally Inoculated With Ebola Virus and Vesicular Stomatitis Virus. Front. Public Health 9:657443. doi: 10.3389/fpubh.2021.657443

Received: 22 January 2021; Accepted: 28 June 2021;
Published: 10 August 2021.

Edited by:

Kate Warpeha, University of Illinois at Chicago, United States

Reviewed by:

Andrea Zille, University of Minho, Portugal
Anthony Griffiths, Boston University, United States
Junki Maruyama, University of Texas Medical Branch at Galveston, United States
Debasis Nayak, Indian Institute of Technology Indore, India

Copyright © 2021 Cutts, Kasloff, Krishnan, Nims, Theriault, Rubino and Ijaz. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: M. Khalid Ijaz, a2hhbGlkLmlqYXomI3gwMDA0MDtyYi5jb20=

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.