Front. Psychiatry, 05 April 2024
Sec. Neuroimaging

Corrigendum: Early improvement predicts clinical outcomes similarly in 10 Hz rTMS and iTBS therapy for depression

  • 1Department of Psychiatry, University of Iowa, Iowa City, IA, United States
  • 2Institute for Clinical and Translational Science, University of Iowa, Iowa City, IA, United States
  • 3Iowa Neuroscience Institute, University of Iowa, Iowa City, IA, United States

A corrigendum on
Early improvement predicts clinical outcomes similarly in 10 Hz rTMS and iTBS therapy for depression

by Spitz NA, Pace BD, Ten Eyck P and Trapp NT (2022). Front. Psychiatry 13:863225. doi: 10.3389/fpsyt.2022.863225

In the published article, there was an error in Table 2 as published. The data was incorrectly transposed into the table. The corrected Table 2 and its caption appear below.

Table 2
www.frontiersin.org

Table 2 Early improvement confusion matrices determining final treatment predictive capacity differences between 10 Hz rTMS and iTBS.

In the published article, there were text errors related to the mislabeled results in Table 2 described above.

A correction has been made to the Abstract Results. This sentence previously stated:

“Results: For both modalities, the NPV related to degree of improvement at t10. NPV for 10 Hz was 80%, 63% and 46% at t10 in those who failed to improve >20, >10, and >0% respectively; while iTBS NPV rates were 65, 50, and 35%. There were not significant differences between protocols at any t10 cut-off assessed, whether research defined 50% improvement as response or data driven kernel density estimates (p = 0.22–0.44).”

The corrected sentence appears below:

“Results: For both modalities, the NPV related to degree of improvement at t10. NPV for 10 Hz was 74%, 82% and 73% at t10 in those who failed to improve >20, >10, and >0% respectively; while iTBS NPV rates were 65, 71, and 60%. There were not significant differences between protocols at any t10 cut-off assessed, whether research defined 50% improvement as response or data driven kernel density estimates (p = 0.46–0.79).”

A correction has been made to the Abstract, Conclusion. This sentence previously stated:

“Conclusion: Patients who fail to achieve >20% improvement by t10 with both 10Hz rTMS and iTBS therapies have ~70% chance of non-response to treatment.”

The corrected sentence appears below:

“Conclusion: Patients who fail to achieve >10% improvement by t10 with both 10Hz rTMS and iTBS therapies have 70-80% chance of non-response to treatment.”

A correction has been made to the Results, Negative Predictive Analyses, paragraph 1. This sentence previously stated:

“For participants who failed to reach >20% improvement at t10, the NPVs for 10Hz rTMS and iTBS were 80.0 and 65.0%, respectively: p = 0.22. When the improvement criterion was decreased to >10% improvement the NPV for 10Hz and iTBS decreased to 62.9 and 50.0%: p = 0.35. Lastly, at >0% improvement the NPV for 10Hz and iTBS decreased further to 45.7 and 5.0%: p = 0.44.”

The corrected sentence appears below:

“For participants who failed to reach >20% improvement at t10, the NPVs for 10Hz rTMS and iTBS were 73.7 and 65.0%, respectively: p = 0.49. When the improvement criterion was decreased to >10% improvement the NPVs for 10Hz and iTBS were 81.5 and 71.4%: p = 0.46. Lastly, at >0% improvement the NPVs for 10Hz and iTBS decreased to 73.3 and 60.0%: p = 0.58.”

A correction has been made to the Results, Negative Predictive Analyses, paragraph 2. The sentence previously stated:

“At >20% improvement at t10, the NPV for 10Hz rTMS and iTBS were 83.9 and 68.4%, respectively: p =0.20. Then at >10% improvement the NPV for 10Hz and iTBS decreased to 67.7 and 52.6%: p = 0.28. Lastly, at >0% improvement the NPV for 10Hz and iTBS decreased further to 48.4 and 36.8%: p = 0.44.”

The corrected sentence appears below:

“At >20% improvement at t10, the NPVs for 10Hz rTMS and iTBS were 68.4 and 65.0%, respectively: p =0.79. Then at >10% improvement the NPVs for 10Hz and iTBS were 77.8 and 71.4%: p = 0.65. Lastly, at >0% improvement the NPVs for 10Hz and iTBS decreased to 66.7 and 60.0%: p = 0.79.”

A correction has been made to the Discussion, paragraph 1. This sentence previously stated:

“Our data demonstrated that as the early treatment improvement criterion increased, so did the NPVs of both 10Hz rTMS and iTBS, while maintaining no significant differences between the two modalities.”

The corrected sentence appears below:

“Our data demonstrated no significant differences between the two modalities.”

A correction has been made in the Discussion, paragraph 3. This sentence previously stated:

“Regarding the precision of the predictive capabilities, our data was comparable with previous studies in that a 20% improvement cut-off by treatment 10 achieved the best NPV as a predictor of rTMS treatment response.”

The corrected sentence appears below:

“Regarding the precision of the predictive capabilities, our data suggested that a 10% improvement cut-off by treatment 10 achieved the best NPV as a predictor of rTMS treatment response, whereas other published literature found 20% to have the highest NPV.”

A correction has been made to the Discussion, Strengths, paragraph 2. This sentence previously stated:

“In general, our study found that non-response to iTBS or 10Hz treatment for major depressive disorder can be predicted with ~70% accuracy in patients exhibiting at least 20% improvement after 10 sessions. Our results will help inform future clinical trials designed to investigate what parameter changes may increase response rates at t10. In addition, although ~70% accuracy may not be robust enough to create stringent treatment parameters for psychiatrists across the map, this data may help guide treatment decisions by identifying patients at risk for treatment non-response at the 2-week time point so therapeutic adjustments can be made to enhance treatment response.”

The corrected sentence appears below:

“In general, our study found that non-response to iTBS or 10 Hz treatment for major depressive disorder can be predicted with 70 to 80% accuracy in patients exhibiting at least 10% improvement after 10 sessions. Our results will help inform future clinical trials designed to investigate what parameter changes may increase response rates at t10. In addition, although 70 to 80% accuracy may not be robust enough to create stringent treatment parameters for psychiatrists across the map, this data may help guide treatment decisions by identifying patients at risk for treatment non-response at the 2-week time point so therapeutic adjustments can be made to enhance treatment response.”

The authors apologize for these errors and state that these do not change the scientific conclusions of the article in any way. The original article has been updated.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Keywords: depression, transcranial magnetic stimulation, theta-burst, clinical practice, observational study, prediction

Citation: Spitz NA, Pace BD, Ten Eyck P and Trapp NT (2024) Corrigendum: Early improvement predicts clinical outcomes similarly in 10 Hz rTMS and iTBS therapy for depression. Front. Psychiatry 15:1404381. doi: 10.3389/fpsyt.2024.1404381

Received: 20 March 2024; Accepted: 22 March 2024;
Published: 05 April 2024.

Edited and Reviewed by:

Stefan Borgwardt, University of Lübeck, Germany

Copyright © 2024 Spitz, Pace, Eyck and Trapp. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Nicholas T. Trapp, bmljaG9sYXMtdHJhcHBAdWlvd2EuZWR1

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.