Skip to main content

MINI REVIEW article

Front. Physiol., 29 April 2022
Sec. Biophysics

Image-Based Experimental Measurement Techniques to Characterize Velocity Fields in Blood Microflows

  • 1Department of Mechanical Engineering, University of Ottawa, Ottawa, ON, Canada
  • 2Centre de Biochimie Structurale, CNRS UMR 5048—INSERM UMR 1054, University of Montpellier, Montpellier, France

Predicting blood microflow in both simple and complex geometries is challenging because of the composition and behavior of the blood at microscale. However, characterization of the velocity in microchannels is the key for gaining insights into cellular interactions at the microscale, mechanisms of diseases, and efficacy of therapeutic solutions. Image-based measurement techniques are a subset of methods for measuring the local flow velocity that typically utilize tracer particles for flow visualization. In the most basic form, a high-speed camera and microscope setup are the only requirements for data acquisition; however, the development of image processing algorithms and equipment has made current image-based techniques more sophisticated. This mini review aims to provide a succinct and accessible overview of image-based experimental measurement techniques to characterize the velocity field of blood microflow. The following techniques are introduced: cell tracking velocimetry, kymographs, micro-particle velocimetry, and dual-slit photometry as entry techniques for measuring various velocity fields either in vivo or in vitro.

Introduction

Microcirculation, which is composed of numerous vessels with diameters typically less than 50 μm, is the main exchange site between blood and tissues. Because blood behavior in the microcirculation cannot be considered as a liquid flow, and is rather regarded as a collection of interacting particles in suspension (Secomb, 2017), the study of blood flow in the microcirculation represents a considerable challenge. Red blood cells (RBCs), which are the most abundant cells found in the blood (40% of the blood volume), may adversely affect blood viscosity (Coull et al., 1991; Baskurt and Meiselman, 2007; Silva-Herdade et al., 2016; Sloop et al., 2020). For instance, blood viscosity increases when blood cells are too abundant (as shown in Erythrocytosis (Pearson and Path, 2001) and hyperleukocytic leukemia (Sharma et al., 1992), less deformable than healthy cells (sickle cell disorders (Connes et al., 2016), hemolytic anemia (Johnson and Ravindranath, 1996), and falciparum anemia (Parrow et al., 2018)), or if they tend to aggregate abnormally (observed in a variety of clinical states such as burns (Levin and Egorihina, 2011), infections and sepsis (Baskurt and Meiselman, 2013), complicated diabetes mellitus (Le Devehat et al., 1990), and malignant and rheumatic diseases (Luquita et al., 2009)). Velocity characterization is a key measurement in numerous studies, such as those analyzing the impact on microcirculation on cellular interactions due to aggregation, blood cell congestion, or platelet migration, to provide useful insights into the mechanisms of disease or to study therapeutic solutions (Bishop et al., 2001a; Long et al., 2004; Ishikawa et al., 2011; Kaliviotis et al., 2011; Sherwood et al., 2012; Pitts and Fenech, 2013b; Kaliviotis et al., 2018; Passos et al., 2019). The advent of microfluidics technology has propelled in vitro studies pertaining to the flow behavior of blood or blood cells in microchannels and the development of blood lab-on-a-chip platforms (Khalid et al., 2017; Maria et al., 2017; Sebastian and Dittrich, 2018; Passos et al., 2019; Abay et al., 2020; Mantegazza et al., 2020; Kihm et al., 2021).

Blood microcirculation studies are performed either in vivo, using intra-vital microscopy, or in a more controlled in vitro environment, taking advantage of the recent development and accessibility of microfluidic chips. The methods described here are image-based measurement techniques that are used in either in vivo or in vitro context, or are sometimes used in both contexts. Over the years, with the increase in the camera sampling frequency, advances in image processing techniques, and increase in computer calculation capacity, the original image-based method (cell tracking) has evolved into more complex methods that coexist and evolve in parallel. Although the choice of the method seems to be linked to the research community (in vivo vs in vitro) or to the experience of the research group and available equipment, this mini review aims to better guide the choice of a suitable method for a desired application by highlighting the capabilities and limitations of different methods. Table 1 summarizes key information as a quick guide.

TABLE 1
www.frontiersin.org

TABLE 1. Comparison of image-based experimental measurement techniques to characterize velocity fields in blood microflows.

In vivo vs in vitro Studies

Numerous methods, such as Doppler, thermodilution, and dye injection, have been used to investigate microvascular flows (Gutterman et al., 2016; Secomb, 2017). However, here, we will focus only on image-based methods.

Intravital microscopy involves the observation of phenomena occurring in living organisms through a microscope. The simplest method is to operate on a small animal and exteriorize an organ, usually in the peritoneum, to be able to image it, which offers visualization of a flat microcirculatory network. The organ is immersed in a saline solution and immobilized with stitches (Bishop et al., 2001b; Long et al., 2004). Other research groups have opted for the implementation of a viewing window, which makes it possible to keep the animal alive for several days and to observe the spatial and temporal evolution of the microcirculation (Patumraj et al., 2005; Cabrales and Carvalho, 2010; Kihm et al., 2021).

Intravital microscopy images contain several artifacts that can influence velocity calculations, such as physiological movements, dilation and contraction of vessels, superposition of vessels in the organ, and light scattering. Open-source image processing tools are available to stabilize the images (e.g., the image stabilizer plugin for ImageJ (Li and Kang, 2008)).

For in vivo studies, the velocity characterization methods aim for a characteristic velocity along each vessel (average velocity or maximum velocity), and the velocity field is then the map of velocities in the microcirculatory network, as shown in Figure 1A. In contrast, in in vitro studies on a single vessel, the methods seek to characterize the velocity profile along a line (Figure 1B) or velocity field in a cross-section (Figure 1C), and sometimes even the 3D velocity field (Figure 1D). In vitro studies, although less physiologically representative, offer the possibility of controlling parameters, such as geometry, flow rate, cell concentration, and pressure drop, while allowing better quantitative and qualitative velocity measurements.

FIGURE 1
www.frontiersin.org

FIGURE 1. (A-D): Visual comparison of typical velocity fields. (A) Color map of local velocity in a conjunctival microcirculation network. Color bar represents velocity in units of mm/s. The velocity vectors were obtained using kymographs image reused per United States government copyright (Khansari et al., 2015). (B) Field of 2D velocity vectors profile across a glass round 150 mm diameter capillary channel where blood, at 10% hematocrit, was flowing at a flow rate of 11.5 ml/min. The velocity vectors were obtained in our lab using micro-PIV. (C) Space-time averaged velocity corresponding to the field of 2D velocity vectors presenting in (B). (D) Instantaneous 3D velocity profile of blood sample at 17% hematocrit in the central plane of a rectangular microchannel in in vitro analysis. Data were obtained using confocal micro-PIV, image reused with permission, copyright, 2022, Elsevier (Lima et al., 2007). (E-H): Methods’ schematic of velocity determination (E) Cell tracking. The image presents in vitro RBCs in semi-circular curved channel (F) Kymograph. The image presents in vivo Sublingual microcirculation. (G) Micro-PIV. Images show fluorescent particles in the blood. (H) Dual slit photometry.

All the methods presented here have a potential to be applied to in vivo and in vitro studies; however, typically, when red blood cell velocity is investigated in a single vessel, cell tracking velocimetry is used, while when a full network is to be analyzed, automatic vessel detection using the kymograph method is more popularly employed. For more detailed velocity field characterization, micro-particle image velocimetry (micro-PIV) and dual-slit methods are the reference methodologies; however, more advanced expertise is required.

Cell Tracking Velocimetry

This technique involves identifying matching particles between the frames to link the positions. The velocities of the particles are then evaluated by dividing the time taken between each consecutive frame (Figure 1E). The first studies using cell tracking velocimetry were published in the 1960s (Bugliarello and Hayden, 1962). This method is simple to implement and captures temporal and spatial speed variations. It is mainly used in vivo and ex-vivo, but is also used in vitro (Omori et al., 2015). The first analysis was performed manually, but with the advent of computer automation, simple free access algorithms are available for quick analysis (Gonciarz, 2021). However, the simplicity of this method leads to several limitations. For instance, to be able to identify individual blood cells, the hematocrit, i.e., the RBC volume fraction, must be very low, or a small fraction of the cells must be fluorescently stained for tracking. RBC staining is a simple procedure that is easy to implement in vitro, and it has also been used in vivo in small animals (Horan et al., 1990; Asai et al., 2007; Agrawal et al., 2017). Only particles in the plane of interest (or focus) should be tracked; this can be done by visual inspection, however, automatic processing considers out-of-focus particles. In addition, RBCs can group due to aggregation, resulting in the tracked objects changing in size, disappearing due to overlapping, or changing in shape due to their rotation. These occurrences affect the accuracy of the automatic image processing (Niazi et al., 2019). Despite these limitations, cell tracking is still a very efficient and accurate method that is widely used to track the passage of single blood cells in microfluidics. A review regarding the comparison of different tracking methods was performed by Chenouard et al. (2014). Open source codes are available for simple tracking (e.g., (Tinevez et al., 2017; Gonciarz, 2021)). Some such codes include a position predictor (e.g., one based on a c) to account for cells that temporarily disappear, while more advanced tools integrate several popular machine learning algorithms to efficiently track objects from brightfield and fluorescence microscopy images (e.g., (39)).

Kymographs

In addition to studying the velocity in a specific vessel, intravital microscopy is also used to investigate tissue perfusion under changing conditions. Typically, studies aim to capture the spatial and temporal variability of microcirculation affecting perfusion. In animal studies, all organs can be investigated, while in human studies, nail, coronary (Figure 1A), and sublingual microcirculation (Figure 1F) can be accessed non-invasively, while microcirculation at other sites, such as the brain, can also be investigated using endoscopies or during surgery.

Common imaging approaches utilize sublingual orthogonal polarization spectral (OPS) imaging, side-stream dark field (SDF) imaging, and incident dark-field (IDF) imaging (Dobbe et al., 2008; Massey and Shapiro, 2016) to record videos of microcirculation activity with enhanced contrast. In either case, high-speed image collection, typically >60 frames per second (fps), is required. For intravital microscopy, image stabilization is the first step in image analysis because of physiologically induced motions such as respiration and cardiac activity. Thus, vessel segmentation is necessary to identify the vasculature as shown in Figure 1A. Finally, the RBC velocities are determined using space–time diagrams, called kymographs, for every time interval and for every vascular segment. An example of a kymograph is shown in Figure 1F. A kymograph is obtained by plotting the intensity in the grayscale level along the vessel segment over time. On this new “image,” where space is encoded along the x-axis while time is plotted along the y-axis, velocity is then deduced from red blood cell shadow (speckles) angles (Jähne, 2005).

Typically, flow characterizations are presented as a color-coded velocity map, as illustrated in Figure 1A. Few commercial software packages are available to complete the full procedure (image acquisition, stabilization, segmentation, and velocity characterization) such as AVA (Microvision Medical B.V., Amsterdam, Netherlands) and CapiScope (KK Research Technology Ltd., Devon, England). The procedure was also implemented in the open source image software ImageJ under the name STAFF (Clendenon et al., 2019a; Clendenon et al., 2019b).

The method is highly dependent on the image quality, particularly image contrast and image sharpness. While illumination techniques have improved, the sharpness of the image is still an important limiting factor because the focus may be difficult to obtain when adjusting the lens on soft tissues and on living subjects, especially during bedside techniques, such as sublingual microcirculation, when the patient is awake. Companies manufacturing commercial acquisition devices, such as USB3 MicroScan (Microvision Medical B.V., Amsterdam, Netherlands), are still improving their focus-monitoring options.

Micro Particle Image Velocimetry

Micro-PIV has been developed to determine the velocity field in microfluidics (Santiago et al., 1998), and since 2000, it has been used to characterize the velocity profiles of blood flowing through micro-channels (Okuda et al., 2003; Koutsiaris and Pogiatzi, 2004; Bitsch et al., 2005; Lima et al., 2006; Pasias et al., 2020). This technique is a particle-based flow visualization method. Figure 1G presents the schematic of the method. Under a microscope, two sequential images of the microflow are recorded at a known time interval (dt) at a fixed position. The pairs of images are used to determine the movement of a group of particles from the first image in the pair to the second image using cross-correlation within sub-regions known as cross-correlation windows (CCW). An interrogation window in the first image is compared within an interrogation window grid in the second image to find the most look-alike windows. The distance between the centers of both windows can be divided by the time elapsed between each frame to calculate the mean velocity of the particles for this position. To capture the displacement of the particles in a micrometric field of view, dt is set in conjunction with the size of the CCW. The average particle displacement between consecutive frames should be approximately a quarter of the size of the CCW (Scharnowski and Kähler, 2020) (from ms to μs depending on the lens magnification and flow velocity). This is a critical parameter because if dt is too large, the particles of the first image could pass beyond the second CCW, resulting in a loss of correlation.

Because this method is a particle-based technique, tracer particles are required. In vivo vs in vitro applications of micro-PIV require different equipment and execution choices. Traditionally, in vivo applications require high-speed photography using the RBCs themselves as tracers (Sugii et al., 2002; Koutsiaris and Pogiatzi, 2004; Bitsch et al., 2005; Lee et al., 2007; Kikuchi and Mochizuki, 2011), while in in vitro studies, artificial micro-fluorescent particles are added to the blood (Okuda et al., 2003; Lima et al., 2006; Lima et al., 2007; Lima et al., 2008; Pitts et al., 2012; Pitts and Fenech, 2013a; Mehri et al., 2015; Mehri et al., 2018; Pasias et al., 2020). Artificial tracer particles have also been used in living subjects in the chicken vitelline network, and embryonic heart (Poelma et al., 2008). Obtaining three-dimensional profiles of cell suspension flow is also possible by coupling micro-PIV with confocal microscopy (Lima et al., 2006). Micro-PIV offers a robust and accurate tool to characterize micro blood flows in 2D or 3D; however, the main disadvantage of this technique is the limitation in cell concentration, as the accuracy drops for RBC concentrations above 20% as the ability to resolve the particles decreases.

Dual Slit Photometry

Dual-slit photometry is a technique developed by Wayland and Johnson (Wayland and Johnson, 1967) and is used to estimate the flow velocity and volumetric flow rates in microchannels (Lee et al., 1983). With optimized settings, it can be used to measure maximal velocity in microchannels both in vivo and in vitro (Roman et al., 2012b). The dual slit is a photometric technique that utilizes two photo sensors (slits) positioned along the vessel. The photosensors can be either photodiode sensors or are taken as two regions of interest in a digitized image. In order to obtain a full velocity profile, the slits’ width could be selected to be as small as 1 to 3 pixels, allowing for multiple velocity measurements along the cross-section of the channel (Roman et al., 2012a). Figure 1H presents the schematic of the method. In each slit, light fluctuations (speckles) are produced by the passage of the RBC flowing through the vessel. A time-dependent signal is captured for each slit in which the time delay between the two signals is obtained by temporal cross-correlation. The RBC velocities are then estimated by assessing the distance between the two slits.

Owing to the large number of RBCs in the channel, the difference in contrast between the cells and suspension media must be sharp to provide a good signal. Furthermore, the RBC rotation, shape, and migration in channels with larger diameters can result in two different signal outputs, preventing an accurate estimation of the velocity profile. For optimized measurement, the technique should be applied to vessels or microchannels that are linear where the slits can be placed at 5 to 10 particle size apart. Finally, the flow through the vessel must be steady, as the technique requires time averaging to ensure statistical convergence of the temporal cross-correlation (Roman et al., 2012b).

Emergent Methods

Conventional methods to infer fluid velocity and pressure measurements or stress fields rely on either analyzing visual images as seen in the optical velocimetry techniques or by enforcing underlying physics without considering the visual data as completed in computational fluid dynamics (CFD). However, with the introduction of a physics-informed neural network, flow visualization image data, such as particles or injected-dye, can be used to derive quantitative information of the flow field while respecting any laws of physics described by a general partial differential equations (PDE) (Raissi et al., 2019). By encoding the Navier-Stokes equations into a neural network, the technique has been applied to flow visualization of both classical fluid problems and more complex flows such as the flow through a microaneurysm-on-a-chip (Raissi et al., 2019; Raissi et al., 2020; Cai et al., 2021). The steps for developing a physics-informed neural network include defining the underlying physical laws, configuring image data to be fed into the neural network, constructing the neural network architecture, training the neural network, verifying the robustness of the model, and finally deploying the model (Raissi et al., 2020; Cai et al., 2021).

The advantage of using a physics-informed neural network is its key property that it can be effectively trained using small datasets (Raissi et al., 2019). Furthermore, with 2D images from microfluidic experiments or from in vivo observations, a full estimate of the 3D velocity, pressure, and stress field of the system can be deduced, which may be challenging to measure experimentally or derive from the images alone (Raissi et al., 2019; Raissi et al., 2020; Cai et al., 2021). In contrast to traditional CFD methods, which are sensitive to boundary conditions, a physics-informed neural network can infer the flow field with the sequence of recorded data without any a priori knowledge of the inlet and outlet conditions. The implementation of a physics-informed neural network may also be considered more accessible as it can be implemented with open-source software such as TensorFlow (Abadi et al., 2016) on a powerful workstation or a local cluster (Raissi et al., 2020; Cai et al., 2021). However, the cost of utilizing a neural network for analysis is the computational cost of the development and training of the model itself, which is more computationally costly compared to simpler conventional optical methodologies relying only on visual images.

Discussion

Table 1 presents a comparison of different methods and important parameters to inform decisions related to the method to be chosen for a specific study.

Tracer Particles

Image-based experimental measurement techniques to characterize the velocity field of blood microflow utilize some form of tracer particles to visualize the flow. In vivo, natural tracers from the cells themselves can be used, while in vitro there are more options available for tracer selection from introducing microbeads, fluorescent molecules, or even marking the cells in the fluid sample. The use of RBCs has the advantage of not requiring particle injection and, more importantly, it avoids confounding interpretation attributed to the modification of the system under study. The use of RBCs as imaging tracers has nevertheless some disadvantages because their diameter is approximately 7 μm, while the diameter of an artificial fluorescent particle is typically on the order of 1 µm. The higher RBC particle size and density are responsible for the decrease in accuracy of the measurement method, increasing the depth of correlation (DOC), i.e., the depth at which "the correlation signal of particles significantly contributes to the correlation function” (Kloostermann et al., 2009; Nguyen et al., 2010; Chayer et al., 2012; Pitts and Fenech, 2013a). To minimize the effects of out-of-focus particles, “image-overlapping post-processing” method has proven to be beneficial specifically for blood micro-PIV (Pitts et al., 2012). When it is not possible to add tracer particles, it was shown that using RBCs as tracer particles has acceptable accuracy when analyzing for the value of the flow rate, but not when assessing for the specific shape of the velocity profile (Chayer et al., 2012; Pitts and Fenech, 2013a).

Volume Fraction and Cell Contrast

Image-based techniques are severely limited by the feeding hematocrit of the system; it is difficult to distinguish cells or tracer particles introduced into the fluid medium in high hematocrit studies. This effectively limits the study of the dynamics of blood microflows using imaging techniques, as the accuracy of measurements decreases as the hematocrit approaches values closer to the physiological values. The volume fraction is a significant factor to consider when selecting an optical measurement technique because if the cell concentration is too high, automatic cell tracking and PIV algorithms are less accurate, while the contrast of the cells can affect the accuracy of kymography and dual-slit photometry. Measuring flow fields in dense suspension of cells would require techniques that utilize sensors that can penetrate denser samples, such as ultrasound localization microscopy (Errico et al., 2015) or those with modifications to RBC opacity, such as converting RBCs into ghost cells (Jansen et al., 2016).

Type of Velocity Field

To extract a characteristic velocity, such as the mean or max velocity, any technique presented here can be utilized. However, to expand into the 2D velocity field of the vessel, cell tracking, micro-PIV, and dual-slit photometry should be considered; in micro-PIV, it is also possible to obtain 3D profiles with additional equipment. With the most basic equipment, the techniques are not necessarily independent and differ by the image processing algorithms that are applied to the acquired images; however, the optimal setting of certain factors, such as the channel configuration, lighting, and lens type, can drastically change the accuracy of the algorithm applied. To obtain more detailed velocity profiles in 3D or under a broad range of flowrates would require more sophisticated equipment such as cameras with higher acquisition rates, pulsed lasers, or filters. This can make profiling of the velocity field in blood microflow an expensive endeavor because the upfront cost of the equipment can be high.

Author Contributions

AL and MF defined the scope of this mini review and contributed equally to the writing of the manuscript.

Funding

This work was funded by the Natural Science and Engineering Research Council of Canada (#RGPIN-2020-07020).

Conflict of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s Note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors, and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

Abadi M., Agarwal A., Barham P., Brevdo E., Chen Z., Citro C., et al. (2016). TensorFlow: A system for Large-Scale Machine Learning. In Proceedings of the 12th USENIX conference on Operating Systems Design and Implementation (OSDI’16), USENIX Association: Savannah, GA, USA, 265–283.

Google Scholar

Abay A., Recktenwald S. M., John T., Kaestner L., Wagner C. (2020). Cross-sectional Focusing of Red Blood Cells in a Constricted Microfluidic Channel. Soft Matter 16 (2), 534–543. doi:10.1039/c9sm01740b

PubMed Abstract | CrossRef Full Text | Google Scholar

Agrawal R., Balne P. K., Tun S. B. B., Sia Wey Y., Khandelwal N., Barathi V. A. (2017). Fluorescent Dye Labeling of Erythrocytes and Leukocytes for Studying the Flow Dynamics in Mouse Retinal Circulation. J. Vis. Exp. (125), e55495. doi:10.3791/55495

PubMed Abstract | CrossRef Full Text | Google Scholar

Asai A., Sahani N., Ouchi Y., Martyn J., Yasuhara S. (2007). In Vivo Micro-circulation Measurement in Skeletal Muscle by Intra-vital Microscopy. J. Vis. Exp. (4), e210. doi:10.3791/210

PubMed Abstract | CrossRef Full Text | Google Scholar

Baskurt O., Meiselman H. J. (2007). “In Vivo hemorheology,” in Handbook of Hemorheology and Hemodynamics. Editors O. K. Baskurt, M. R. Hardeman, and M. W. Rampling (Amsterdam: IOS press), 322–338.

Google Scholar

Baskurt O. K., Meiselman H. J. (2013). Erythrocyte Aggregation: Basic Aspects and Clinical Importance. Clin. Hemorheol. Microcirc. 53 (1–2), 23–37. doi:10.3233/CH-2012-1573

PubMed Abstract | CrossRef Full Text | Google Scholar

Bishop J. J., Popel A. S., Intaglietta M., Johnson P. C. (2001b). Rheological Effects of Red Blood Cell Aggregation in the Venous Network: A Review of Recent Studies. Biorheology 38, 263–274.

Google Scholar

Bishop J. J., Popel A. S., Intaglietta M., Johnson P. C. (2001a). Effects of Erythrocyte Aggregation and Venous Network Geometry on Red Blood Cell Axial Migration. Am. J. Physiology-Heart Circulatory Physiol. 281 (2), H939–H950. doi:10.1152/ajpheart.2001.281.2.h939

PubMed Abstract | CrossRef Full Text | Google Scholar

Bitsch L., Olesen L. H., Westergaard C. H., Bruus H., Klank H., Kutter J. P. (2005). Micro Particle-Image Velocimetry of Bead Suspensions and Blood Flows. Exp. Fluids 39 (3), 507–513. doi:10.1007/s00348-005-0967-7

CrossRef Full Text | Google Scholar

Bugliarello G., Hayden J. W. (1962). High-speed Microcinematographic Studies of Blood Flow In Vitro. Science 138, 981–983. doi:10.1126/science.138.3544.981

PubMed Abstract | CrossRef Full Text | Google Scholar

Cabrales P., Carvalho L. J. M. (2010). Intravital Microscopy of the Mouse Brain Microcirculation Using a Closed Cranial Window. J. Vis. Exp. (45), 2184. doi:10.3791/2184

PubMed Abstract | CrossRef Full Text | Google Scholar

Cai S., Li H., Zheng F., Kong F., Dao M., Karniadakis G. E., et al. (2021). Artificial Intelligence Velocimetry and Microaneurysm-On-A-Chip for Three-Dimensional Analysis of Blood Flow in Physiology and Disease. Proc. Natl. Acad. Sci. U.S.A. 118 (13), e2100697118. doi:10.1073/pnas.2100697118

PubMed Abstract | CrossRef Full Text | Google Scholar

Chayer B., L Pitts K., Cloutier G., Fenech M. (2012). Velocity Measurement Accuracy in Optical Microhemodynamics: Experiment and Simulation. Physiol. Meas. 33 (10), 1585–1602. doi:10.1088/0967-3334/33/10/1585

PubMed Abstract | CrossRef Full Text | Google Scholar

Chenouard N., Smal I., de Chaumont F., Maška M., Sbalzarini I. F., Gong Y., et al. (2014). Objective Comparison of Particle Tracking Methods. Nat. Methods 11 (3), 281–289. doi:10.1038/nmeth.2808

PubMed Abstract | CrossRef Full Text | Google Scholar

Clendenon S. G., Fu X., Von Hoene R. A., Clendenon J. L., Sluka J. P., Winfree S., et al. (2019a). A Simple Automated Method for Continuous Fieldwise Measurement of Microvascular Hemodynamics. Microvasc. Res. 123, 7–13. doi:10.1016/j.mvr.2018.11.010

CrossRef Full Text | Google Scholar

Clendenon S. G., Fu X., Von Hoene R. A., Clendenon J. L., Sluka J. P., Winfree S., et al. (2019b). Spatial Temporal Analysis of Fieldwise Flow in Microvasculature. J. Vis. Exp. (153), e60493. doi:10.3791/60493

PubMed Abstract | CrossRef Full Text | Google Scholar

Connes P., Alexy T., Detterich J., Romana M., Hardy-Dessources M.-D., Ballas S. K. (2016). The Role of Blood Rheology in Sickle Cell Disease. Blood Rev. 30 (2), 111–118. doi:10.1016/j.blre.2015.08.005

PubMed Abstract | CrossRef Full Text | Google Scholar

Coull B. M., Beamer N., de Garmo P., Sexton G., Nordt F., Knox R., et al. (1991). Chronic Blood Hyperviscosity in Subjects with Acute Stroke, Transient Ischemic Attack, and Risk Factors for Stroke. Stroke 22 (2), 162–168. doi:10.1161/01.STR.22.2.162

PubMed Abstract | CrossRef Full Text | Google Scholar

Dobbe J. G. G., Streekstra G. J., Atasever B., van Zijderveld R., Ince C. (2008). Measurement of Functional Microcirculatory Geometry and Velocity Distributions Using Automated Image Analysis. Med. Biol. Eng. Comput. 46 (7), 659. doi:10.1007/s11517-008-0349-4

PubMed Abstract | CrossRef Full Text | Google Scholar

Errico C., Pierre J., Pezet S., Desailly Y., Lenkei Z., Couture O., et al. (2015). Ultrafast Ultrasound Localization Microscopy for Deep Super-resolution Vascular Imaging. Nature 527 (7579), 499–502. doi:10.1038/nature16066

PubMed Abstract | CrossRef Full Text | Google Scholar

Gonciarz K. (2021) Particle Tracker, Image J. Dresden, Germany. Available at: https://imagej.net/plugins/particle-tracker, (Accessed April 08, 2022).

Google Scholar

Gutterman D. D., Chabowski D. S., Kadlec A. O., Durand M. J., Freed J. K., Ait-Aissa K., et al. (2016). The Human Microcirculation. Circ. Res. 118 (1), 157–172. doi:10.1161/CIRCRESAHA.115.305364

PubMed Abstract | CrossRef Full Text | Google Scholar

Horan P. K., Melnicoff M. J., Jensen B. D., Slezak S. E. (1990). Chapter 42 Fluorescent Cell Labeling for In Vivo and In Vitro Cell Tracking. Methods Cel Biol. 33, 469–490. doi:10.1016/S0091-679X(08)60547-6

CrossRef Full Text | Google Scholar

Ishikawa T., Fujiwara H., Matsuki N., Yoshimoto T., Imai Y., Ueno H., et al. (2011). Asymmetry of Blood Flow and Cancer Cell Adhesion in a Microchannel with Symmetric Bifurcation and confluence. Biomed. Microdevices 13 (1), 159–167. doi:10.1007/s10544-010-9481-7

PubMed Abstract | CrossRef Full Text | Google Scholar

Jähne B. (2005). Digital Image Processing: 6th Revised and Extended Edition. Berlin: Springer, 403–406. doi:10.1007/3-540-27563-0

CrossRef Full Text | Google Scholar

Jansen S. V., Müller I., Nachtsheim M., Schmitz-Rode T., Steinseifer U. (2016). Ghost Cell Suspensions as Blood Analogue Fluid for Macroscopic Particle Image Velocimetry Measurements. Artif. Organs 40 (2), 207–212. doi:10.1111/aor.12511

PubMed Abstract | CrossRef Full Text | Google Scholar

Johnson R. M., Ravindranath Y. (1996). Osmotic Scan Ektacytometry in Clinical Diagnosis. J. Pediatr. Hematology/Oncology 18 (2), 122–129. doi:10.1097/00043426-199605000-00005

PubMed Abstract | CrossRef Full Text | Google Scholar

Kaliviotis E., Dusting J., Balabani S. (2011). Spatial Variation of Blood Viscosity: Modelling Using Shear fields Measured by a μPIV Based Technique. Med. Eng. Phys. 33 (7), 824–831. doi:10.1016/j.medengphy.2010.09.004

PubMed Abstract | CrossRef Full Text | Google Scholar

Kaliviotis E., Sherwood J. M., Balabani S. (2018). Local Viscosity Distribution in Bifurcating Microfluidic Blood Flows. Phys. Fluids 30, 030706. doi:10.1063/1.5011373

CrossRef Full Text | Google Scholar

Khalid N., Kobayashi I., Nakajima M. (2017). Recent Lab‐on‐chip Developments for Novel Drug Discovery. Wires Syst. Biol. Med. 9, e1381. doi:10.1002/wsbm.1381

CrossRef Full Text | Google Scholar

Khansari M. M., Wanek J., E Felder A., Camardo N., Shahidi M. (2015). Automated Assessment of Hemodynamics in the Conjunctival Microvasculature Network. IEEE Trans. Med. Imaging 35 (2), 605–611. doi:10.1109/TMI.2015.2486619

PubMed Abstract | CrossRef Full Text | Google Scholar

Kihm A., Quint S., Laschke M. W., Menger M. D., John T., Kaestner L., et al. (2021). Lingering Dynamics in Microvascular Blood Flow. Biophysical J. 120 (3), 432–439. doi:10.1016/J.BPJ.2020.12.012

CrossRef Full Text | Google Scholar

Kikuchi K., Mochizuki O. (2011). Micro-PIV (Micro Particle Image Velocimetry) Visualization of Red Blood Cells (RBCs) Sucked by a Female Mosquito. Meas. Sci. Technol. 22, 064002. doi:10.1088/0957-0233/22/6/064002

CrossRef Full Text | Google Scholar

Kloostermann A., Poelma C., Westerweel J. (2009). “Accuracy of the Micro-PIV Method for Biological Applications. In the proceeding of the 8th International Symposium on PIV, Melbourne, Victoria, Australia, 25–28.

Google Scholar

Koutsiaris A. G., Pogiatzi A. (2004). Velocity Pulse Measurements in the Mesenteric Arterioles of Rabbits. Physiol. Meas. 25, 15–25. doi:10.1088/0967-3334/25/1/002

PubMed Abstract | CrossRef Full Text | Google Scholar

Le Devehat C., Vimeux M., Bondoux G., Khodabandehlou T. (1990). Red Blood Cell Aggregation in Diabetes Mellitus. Int. Angiol 9 (1), 11–15.

PubMed Abstract | Google Scholar

Lee J. Y., Ji H. S., Lee S. J. (2007). Micro-PIV Measurements of Blood Flow in Extraembryonic Blood Vessels of Chicken Embryos. Physiol. Meas. 28 (10), 1149–1162. doi:10.1088/0967-3334/28/10/002

PubMed Abstract | CrossRef Full Text | Google Scholar

Lee T. Q., Schmid-Schönbein G. W., Zweifach B. W. (1983). The Application of an Improved Dual-Slit Photometric Analyzer for Volumetric Flow Rate Measurements in Microvessels. Microvasc. Res. 26 (3), 351–361. doi:10.1016/0026-2862(83)90084-5

PubMed Abstract | CrossRef Full Text | Google Scholar

Levin G. Y., Egorihina M. N. (2011). Aggregation of Erythrocytes in Burn Disease. Int. J. Burns Trauma 1 (1), 34–41. Available at: http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=PMC3415941.

PubMed Abstract | Google Scholar

Li K., Kang S. (2008) The Image Stabilizer Plugin for ImageJ. Available at: http://www.cs.cmu.edu/∼kangli/code/Image_Stabilizer.html (Accessed: 29 July 2021).

Google Scholar

Lima R., Wada S., Takeda M., Tsubota K.-i., Yamaguchi T. (2007). In Vitro confocal Micro-PIV Measurements of Blood Flow in a Square Microchannel: The Effect of the Haematocrit on Instantaneous Velocity Profiles. J. Biomech. 40 (12), 2752–2757. doi:10.1016/j.jbiomech.2007.01.012

PubMed Abstract | CrossRef Full Text | Google Scholar

Lima R., Wada S., Tanaka S., Takeda M., Ishikawa T., Tsubota K.-i., et al. (2008). In Vitro blood Flow in a Rectangular PDMS Microchannel: Experimental Observations Using a Confocal Micro-PIV System. Biomed. Microdevices 10 (2), 153–167. doi:10.1007/s10544-007-9121-z

PubMed Abstract | CrossRef Full Text | Google Scholar

Lima R., Wada S., Tsubota K.-i., Yamaguchi T. (2006). Confocal Micro-PIV Measurements of Three-Dimensional Profiles of Cell Suspension Flow in a Square Microchannel. Meas. Sci. Technol. 17 (4), 797–808. doi:10.1088/0957-0233/17/4/026

CrossRef Full Text | Google Scholar

Long D. S., Smith M. L., Pries A. R., Ley K., Damiano E. R. (2004). Microviscometry Reveals Reduced Blood Viscosity and Altered Shear Rate and Shear Stress Profiles in Microvessels after Hemodilution. Proc. Natl. Acad. Sci. U.S.A. 101 (27), 10060–10065. doi:10.1073/pnas.0402937101

PubMed Abstract | CrossRef Full Text | Google Scholar

Luquita A., Urli L., Svetaz M. J., Gennaro A. M., Volpintesta R., Palatnik S., et al. (2009). Erythrocyte Aggregation in Rheumatoid Arthritis: Cell and Plasma Factor's Role. Clin. Hemorheol. Microcirc. 41 (1), 49–56. doi:10.3233/CH-2009-1154

PubMed Abstract | CrossRef Full Text | Google Scholar

Mantegazza A., Ungari M., Clavica F., Obrist D. (2020). Local vs. Global Blood Flow Modulation in Artificial Microvascular Networks: Effects on Red Blood Cell Distribution and Partitioning. Front. Physiol. 11, 1117. doi:10.3389/fphys.2020.566273

PubMed Abstract | CrossRef Full Text | Google Scholar

Maria M. S., Chandra T. S., Sen A. K. (2017). Capillary Flow-Driven Blood Plasma Separation and On-Chip Analyte Detection in Microfluidic Devices. Microfluid Nanofluid 21, 1–21. doi:10.1007/s10404-017-1907-6

CrossRef Full Text | Google Scholar

Maška M., Ulman V., Svoboda D., Matula P., Matula P., Ederra C., et al. (2014). A Benchmark for Comparison of Cell Tracking Algorithms. Bioinformatics 30 (11), 1609–1617. doi:10.1093/bioinformatics/btu080

PubMed Abstract | CrossRef Full Text | Google Scholar

Massey M. J., Shapiro N. I. (2016). A Guide to Human In Vivo Microcirculatory Flow Image Analysis. Crit. Care 20, 35. doi:10.1186/s13054-016-1213-9

PubMed Abstract | CrossRef Full Text | Google Scholar

Mehri R., Mavriplis C., Fenech M. (2015). Controlled Microfluidic Environment for Dynamic Investigation of Red Blood Cell Aggregation. J. Vis. Exp. 2015 (100), e52719. doi:10.3791/52719

PubMed Abstract | CrossRef Full Text | Google Scholar

Mehri R., Mavriplis C., Fenech M. (2018). Red Blood Cell Aggregates and Their Effect on Non-newtonian Blood Viscosity at Low Hematocrit in a Two-Fluid Low Shear Rate Microfluidic System. PLoS ONE 13 (7), e0199911. doi:10.1371/journal.pone.0199911

PubMed Abstract | CrossRef Full Text | Google Scholar

Nguyen C. V., Fouras A., Carberry J. (2010). Improvement of Measurement Accuracy in Micro PIV by Image Overlapping. Exp. Fluids 49 (3), 701–712. doi:10.1007/s00348-010-0837-9

CrossRef Full Text | Google Scholar

Niazi E., McDonald J. G., Fenech M. (2019). An Automated Method for Size and Velocity Distribution Measurement in a Particle-Laden Flow. Adv. Eng. Softw. 134, 10–21. doi:10.1016/j.advengsoft.2019.05.002

CrossRef Full Text | Google Scholar

Okuda R., Sugii Y., Okamoto K. (2003). “Velocity Measurement of Blood Flow in a Microtube Using Micro PIV System,” in In the proceedings of the 4th Pacific Symposium on Flow Visualization and Image Processing, Chamonix, France, 4–7. Available at: http://psfvip4.univ-fcomte.fr/Fpsfvip4/sources/F4084.pdf.

Google Scholar

Omori T., Imai Y., Kikuchi K., Ishikawa T., Yamaguchi T. (2015). Hemodynamics in the Microcirculation and in Microfluidics. Ann. Biomed. Eng. 43 (1), 238–257. doi:10.1007/s10439-014-1180-8

PubMed Abstract | CrossRef Full Text | Google Scholar

Parrow N. L., Violet P.-C., Tu H., Nichols J., Pittman C. A., Fitzhugh C., et al. (2018). Measuring Deformability and Red Cell Heterogeneity in Blood by Ektacytometry. J. Vis. Exp. 2018 (131), 56910. doi:10.3791/56910

PubMed Abstract | CrossRef Full Text | Google Scholar

Pasias D., Passos A., Constantinides G., Balabani S., Kaliviotis E. (2020). Surface Tension Driven Flow of Blood in a Rectangular Microfluidic Channel: Effect of Erythrocyte Aggregation. Phys. Fluids 32 (7), 071903. doi:10.1063/5.0008939

CrossRef Full Text | Google Scholar

Passos A., Sherwood J. M., Kaliviotis E., Agrawal R., Pavesio C., Balabani S. (2019). The Effect of Deformability on the Microscale Flow Behavior of Red Blood Cell Suspensions. Phys. Fluids 31 (9), 091903. doi:10.1063/1.5111189

CrossRef Full Text | Google Scholar

Patumraj S., Yoysungnoen P., Kachonrattanadet P., Wirachwong P. (2005). Tumor Neocapillary Density in Hepatocellular Carcinoma Cells Implanted Nude Mice Model. Clin. Hemorheol. Microcirc. 33 (2), 137–144.

PubMed Abstract | Google Scholar

Pearson T. C., Path F. R. C. (2001). Hemorheology in the Erythrocytoses. Mt Sinai J. Med. 68 (3), 182–191.

PubMed Abstract | Google Scholar

Pitts K. L., Fenech M. (2013a). High Speed versus Pulsed Images for Micro-particle Image Velocimetry: a Direct Comparison of Red Blood Cells versus Fluorescing Tracers as Tracking Particles. Physiol. Meas. 34 (10), 1363–1374. doi:10.1088/0967-3334/34/10/1363

PubMed Abstract | CrossRef Full Text | Google Scholar

Pitts K. L., Fenech M. (2013b). Micro-particle Image Velocimetry for Velocity Profile Measurements of Micro Blood Flows. J. Vis. Exp. (74), e50314. doi:10.3791/50314

PubMed Abstract | CrossRef Full Text | Google Scholar

Pitts K. L., Mehri R., Mavriplis C., Fenech M. (2012). Micro-particle Image Velocimetry Measurement of Blood Flow: Validation and Analysis of Data Pre-processing and Processing Methods. Meas. Sci. Technol. 23 (10), 105302. doi:10.1088/0957-0233/23/10/105302

CrossRef Full Text | Google Scholar

Poelma C., Vennemann P., Lindken R., Westerweel J. (2008). In Vivo blood Flow and wall Shear Stress Measurements in the Vitelline Network. Exp. Fluids 45 (4), 703–713. doi:10.1007/s00348-008-0476-6

CrossRef Full Text | Google Scholar

Raissi M., Perdikaris P., Karniadakis G. E. (2019). Physics-informed Neural Networks: A Deep Learning Framework for Solving Forward and Inverse Problems Involving Nonlinear Partial Differential Equations. J. Comput. Phys. 378, 686–707. doi:10.1016/j.jcp.2018.10.045

CrossRef Full Text | Google Scholar

Raissi M., Yazdani A., Karniadakis G. E. (2020). Hidden Fluid Mechanics: Learning Velocity and Pressure fields from Flow Visualizations. Science 367 (6481), 1026–1030. doi:10.1126/science.aaw4741

PubMed Abstract | CrossRef Full Text | Google Scholar

Roman S., Lorthois S., Duru P., Risso F. (2012a). An Optimized Technique for Red Blood Cells Velocity Measurement in Microvessels. J. Biomech. 45, S35. doi:10.1016/s0021-9290(12)70036-2

CrossRef Full Text | Google Scholar

Roman S., Lorthois S., Duru P., Risso F. (2012b). Velocimetry of Red Blood Cells in Microvessels by the Dual-Slit Method: Effect of Velocity Gradients. Microvasc. Res. 84 (3), 249–261. doi:10.1016/j.mvr.2012.08.006

PubMed Abstract | CrossRef Full Text | Google Scholar

Santiago J. G., Wereley S. T., Meinhart C. D., Beebe D. J., Adrian R. J. (1998). A Particle Image Velocimetry System for Microfluidics. Experiments in Fluids 25 (4), 316–319. doi:10.1007/s003480050235

CrossRef Full Text | Google Scholar

Scharnowski S., Kähler C. J. (2020). Particle Image Velocimetry - Classical Operating Rules from Today's Perspective. Opt. Lasers Eng. 135, 106185. doi:10.1016/j.optlaseng.2020.106185

CrossRef Full Text | Google Scholar

Sebastian B., Dittrich P. S. (2018). Microfluidics to Mimic Blood Flow in Health and Disease. Annu. Rev. Fluid Mech. 50, 483–504. doi:10.1146/annurev-fluid-010816-060246

CrossRef Full Text | Google Scholar

Secomb T. W. (2017). Blood Flow in the Microcirculation. Annu. Rev. Fluid Mech. 49, 443–461. doi:10.1146/annurev-fluid-010816-060302

CrossRef Full Text | Google Scholar

Sharma K., Puniyani R. R., Bhat S. V., Advani S. H., Hegde U., Rao S. (1992). Blood Viscosity Parameter Correlation with Types of Leukemia. Physiol. Chem. Phys. Med. NMR 24 (2), 159–164. Available at: https://pubmed.ncbi.nlm.nih.gov/1508991/ (Accessed December 13, 2021).

PubMed Abstract | Google Scholar

Sherwood J. M., Dusting J., Kaliviotis E., Balabani S. (2012). The Effect of Red Blood Cell Aggregation on Velocity and Cell-Depleted Layer Characteristics of Blood in a Bifurcating Microchannel. Biomicrofluidics 6 (2), 024119. doi:10.1063/1.4717755

CrossRef Full Text | Google Scholar

Silva-Herdade A. S., Andolina G., Faggio C., Calado Â., Saldanha C. (2016). Erythrocyte Deformability - A Partner of the Inflammatory Response. Microvasc. Res. 107, 34–38. doi:10.1016/j.mvr.2016.04.011

PubMed Abstract | CrossRef Full Text | Google Scholar

Sloop G. D., De Mast Q., Pop G., Weidman J. J., St. Cyr J. A. (2020). The Role of Blood Viscosity in Infectious Diseases. Cureus 12 (2), e7090. doi:10.7759/cureus.7090

PubMed Abstract | CrossRef Full Text | Google Scholar

Sugii Y., Nishio S., Okamoto K. (2002). In vivoPIV Measurement of Red Blood Cell Velocity Field in Microvessels Considering Mesentery Motion. Physiol. Meas. 23 (2), 403–416. doi:10.1088/0967-3334/23/2/315

PubMed Abstract | CrossRef Full Text | Google Scholar

Tinevez J.-Y., Perry N., Schindelin J., Hoopes G. M., Reynolds G. D., Laplantine E., et al. (2017). TrackMate: An Open and Extensible Platform for Single-Particle Tracking. Methods 115, 80–90. doi:10.1016/J.YMETH.2016.09.016

PubMed Abstract | CrossRef Full Text | Google Scholar

Wayland H., Johnson P. C. (1967). Erythrocyte Velocity Measurement in Microvessels by a Two-Slit Photometric Method. J. Appl. Physiol. 22 (2), 333–337. doi:10.1152/jappl.1967.22.2.333

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: microcirculation, kymographs, micro-particle velocimetry, dual-slit photometry, cell tracking

Citation: Le AV and Fenech M (2022) Image-Based Experimental Measurement Techniques to Characterize Velocity Fields in Blood Microflows. Front. Physiol. 13:886675. doi: 10.3389/fphys.2022.886675

Received: 28 February 2022; Accepted: 04 April 2022;
Published: 29 April 2022.

Edited by:

Stavroula Balabani, University College London, United Kingdom

Reviewed by:

Georgios C. Georgiou, University of Cyprus, Cyprus

Copyright © 2022 Le and Fenech. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Marianne Fenech, bWZlbmVjaEB1b3R0YXdhLmNh

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.