Skip to main content

ORIGINAL RESEARCH article

Front. Oncol., 31 October 2023
Sec. Radiation Oncology

Robustness of hypofractionated breast radiotherapy after breast-conserving surgery with free breathing

Kunzhi ChenKunzhi Chen1Wuji SunWuji Sun1Tao HanTao Han1Lei YanLei Yan1Minghui SunMinghui Sun1Wenming XiaWenming Xia1Libo WangLibo Wang1Yinghua ShiYinghua Shi1Chao GeChao Ge1Xu YangXu Yang1Yu LiYu Li1Huidong Wang,,*Huidong Wang1,2,3*
  • 1Department of Radiation Oncology & Therapy, The First Hospital of Jilin University, Changchun, China
  • 2Jilin Provincial Key Laboratory of Radiation Oncology & Therapy, Department of Radiation Oncology & Therapy, The First Hospital of Jilin University, Changchun, China
  • 3NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, China

Purpose: This study aimed to evaluate the robustness with respect to the positional variations of five planning strategies in free-breathing breast hypofractionated radiotherapy (HFRT) for patients after breast-conserving surgery.

Methods: Twenty patients who received breast HFRT with 42.72 Gy in 16 fractions were retrospectively analyzed. Five treatment planning strategies were utilized for each patient, including 1) intensity-modulated radiation therapy (IMRT) planning (IMRTpure); 2) IMRT planning with skin flash tool extending and filling the fluence outside the skin by 2 cm (IMRTflash); 3) IMRT planning with planning target volume (PTV) extended outside the skin by 2 cm in the computed tomography dataset (IMRTePTV); 4) hybrid planning, i.e., 2 Gy/fraction three-dimensional conformal radiation therapy combined with 0.67 Gy/fraction IMRT (IMRThybrid); and 5) hybrid planning with skin flash (IMRThybrid-flash). All plans were normalized to 95% PTV receiving 100% of the prescription dose. Six additional plans were created with different isocenter shifts for each plan, which were 1 mm, 2 mm, 3 mm, 5 mm, 7 mm, and 10 mm distally in the X (left-right) and Y (anterior-posterior) directions, namely, (X,Y), to assess their robustness, and the corresponding doses were recalculated. Variation of dosimetric parameters with increasing isocenter shift was evaluated.

Results: All plans were clinically acceptable. In terms of robustness to isocenter shifts, the five planning strategies followed the pattern IMRTePTV, IMRThybrid-flash, IMRTflash, IMRThybrid, and IMRTpure in descending order. V95% of IMRTePTV maintained at 99.6% ± 0.3% with a (5,5) shift, which further reduced to 98.2% ± 2.0% with a (10,10) shift. IMRThybrid-flash yielded the robustness second to IMRTePTV with less risk from dose hotspots, and the corresponding V95% maintained >95% up until (5,5).

Conclusion: Considering the dosimetric distribution and robustness in breast radiotherapy, IMRTePTV performed best at maintaining high target coverage with increasing isocenter shift, while IMRThybrid-flash would be adequate with positional uncertainty<5 mm.

1 Introduction

Over the past decades, adjuvant post-operative radiotherapy has been the standard treatment for patients with breast cancer receiving breast-conserving surgery to reduce local recurrence (13). Several clinical trials have shown that moderately hypofractionated radiotherapy (HFRT), typically delivered with a dose of 40–42.72 Gy in 15–16 fractions, provides equivalent tumor control, long-term toxicity, and cosmetic outcome compared with prolonged conventionally fractionated radiotherapy with a standard dose of 50–50.4 Gy in 25–28 fractions (49). Hypofractionation schedules reduce the fraction number and overall treatment period, which is beneficial for patients and treatment providers (9, 10).

Intensity-modulated radiation therapy (IMRT) is utilized in treating breast cancer for its high target dose coverage and homogeneity. However, the dosimetric effects of inter- and intra-fraction positioning variations have always been a concern in highly modulated fields owing to the challenging patient setup and the anatomical variations caused by respiratory motion, breast shape change, and edema (1113). Various imaging guidance and motion management techniques, such as deep inspiration breath hold (1416), continuous positive airway pressure (14), four-dimensional computed tomography (11), cone-beam computed tomography (17), and surface tracking (15, 16, 18), have been developed to limit dosimetric error. Nonetheless, these techniques could be physically challenging for some patients, and the dosimetric error can only be alleviated but not eliminated. Therefore, the robustness of treatment delivery should be taken into account during treatment planning, especially for HFRT with free breathing, considering that the potential hazard from one fraction could bring a rather substantial effect to the treatment with fewer fractions.

Several techniques have been developed over the years to assure the robustness of breast radiotherapy, including skin flash (1921), planning target volume (PTV) extension, which is also known as the “virtual bolus” technique (2123), and hybrid planning (24, 25). The skin flash technique uses a flash region consisting of an extended irradiation volume outside the skin to account for positional variations, which can be achieved in several ways, such as using the skin flash tool integrated into the Eclipse treatment planning system (TPS; Varian Medical Systems, Palo Alto, CA, USA). The PTV extension technique involves the modification of the computed tomography (CT) dataset by extending the PTV outside the skin (21). Treatment plans would be optimized based on the modified CT data and subsequently copied and recalculated onto the original CT dataset (1921). The hybrid planning technique consists of a combination of IMRT and three-dimensional conformal radiation therapy (3D-CRT) (24, 25). Positional and anatomical variations are accounted for by manually opening the jaw and using a multi-leaf collimator (MLC) for 3D-CRT fields.

Previous studies have discussed the importance of robustness and the efficiency of some techniques in assuring adequate target coverage during irradiation (21). However, to our knowledge, the dosimetric and robustness-wise differences among the above planning strategies remain unclear, especially for HFRT. This study aimed to compare the dosimetric characteristics and robustness with respect to positional variations among five planning strategies for free-breathing breast HFRT.

2 Materials and methods

The workflow of this study is summarized in Figure 1 and detailed as follows.

FIGURE 1
www.frontiersin.org

Figure 1 Overall workflow of this study.

2.1 Patient selection and simulation

Twenty patients with breast cancer (10 on the left side and 10 on the right side) treated with HFRT after breast-conserving surgery were retrospectively analyzed in this study. Prophylactic supraclavicular irradiation and partial simultaneous integrated boost were not involved for all patients. Patients were between 35 and 76 years of age with a median of 50 years.

Patients were immobilized in a supine position with a CIVCO breast board (CIVCO Medical Solutions, Coralville, IA, USA). CT simulation was performed for all patients with free breathing on a Philips Brilliance Big Bore CT scanner (Philips Healthcare, Cleveland, OH, USA) with a slice thickness of 5 mm. The CT datasets were subsequently transferred to the Varian Eclipse TPS version 15.6 (Varian Medical Systems, Palo Alto, CA, USA).

2.2 Target definition

According to the National Comprehensive Cancer Network guidelines (2018) (26), Report No. 9804 of the Radiation Therapy Oncology Group (27, 28), and the ESTRO consensus guideline (29, 30), the clinical target volume (CTV) was contoured in the TPS, including intact breast tissue and tumor bed on the ipsilateral side. The PTV was defined by adding an isotropic 5-mm margin to the CTV. The PTV was limited posteriorly to the lung surface and anteriorly within 4 mm from the skin. Subsequently, the organs at risk (OARs) were contoured, including the lung, heart, and liver. The breast target volume of each patient is summarized in Supplementary Table 1.

2.3 Treatment planning

A total dose of 42.72 Gy in 16 fractions (i.e., 2.67 Gy per fraction) was prescribed for the PTV of all patients. Treatment plans were optimized with Photon Optimizer (version 15.6) in Eclipse TPS for a Varian TrueBeam linear accelerator equipped with a 120-leaf Millennium MLC using 6-MV beams. The maximum dose rate was 600 MUs/min. The AXB algorithm version 15.6 was used for dose calculation with a 2.5-mm grid.

For each patient, five treatment plans were created using different strategies, and the initial optimization parameters were kept the same, as well as the following plan fine-tuning. All plans were normalized to 95% of the PTV receiving 100% of the prescription dose. All plans met the dose–volume constraints based on the guidelines from the National Cancer Center and the National Cancer Quality Control Center of China (31). All plans can be considered clinically acceptable. The main constraints were summarized as follows: PTV V110%< 5% and V107%< 15%; ipsilateral lung Dmean< 10 Gy, V20Gy< 20%, and V5Gy< 40%; heart Dmean< 10 Gy (left-side breast cancer). The adopted planning strategies are summarized as follows.

1) IMRT planning (IMRTpure). The IMRT plan consisted of four or six fields depending on the thickness of the breast tissue. The technical feature is shown in the upper panel of Figure 2A.

2) IMRT planning with skin flash (IMRTflash). The technical feature is shown in the upper panel of Figure 2B. After plan optimization, the fluence of each field was extended outside the skin by 2 cm with the skin flash tool in the Eclipse TPS. Regarding the skin flash tool settings, the “nearest cell” fill method was used with the brush size set at 20 mm, the brush ceiling set at 0.01, and the cut range set at 7 mm.

3) IMRT planning with extended PTV (referred to as IMRTePTV). The “PTV+2” structure was defined by extending the PTV by 2 cm outside of the body. The region of PTV+2 excluding the body was assigned a Hounsfield unit (HU) equal to the average HU of the PTV. Based on this modified CT dataset, an IMRT plan was created and optimized on the PTV+2 with the same parameters as IMRTpure. This plan was subsequently copied to the original CT dataset and recalculated. The technical feature is shown in the upper panel of Figure 2C.

4) Hybrid planning (IMRThybrid). It is the combination of a 2 Gy/fraction 3D-CRT plan and a 0.67/fraction IMRT plan. The 3D-CRT plan consisted of two tangential fields with the MLC manually opened by 2 cm outside the body. The IMRT plan consisted of two or four fields depending on the thickness of the breast tissue. The technical feature is shown in the upper panel of Figure 2D.

5) Hybrid planning with skin flash (IMRThybrid-flash). This plan was obtained by extending the fluence of each IMRT field in IMRThybrid outside the skin by 2 cm using the skin flash tool. The technical feature is shown in the upper panel of Figure 2E.

FIGURE 2
www.frontiersin.org

Figure 2 Technical features of five planning strategies (upper panel) and corresponding dosimetric distributions for one patient (lower panel). (A) IMRTpure, (B) IMRTflash, (C) IMRTePTV, (D) IMRThybrid, (E) IMRThybrid-flash.

2.4 Plan comparison

The dose distributions of the five planning strategies were compared using the following parameters: conformity index (CI), mean dose (Dmean) to PTV, maximum dose to 2 cc of PTV (D2cc), the percentage of PTV receiving 107% of the prescription dose (V107%), mean dose to the heart (left-side breast cancer) or liver (right-side breast cancer), mean dose to the ipsilateral lung, and the percentage of lung receiving 5 Gy (V5), 10 Gy (V10), and 20 Gy (V20). The CI was calculated using Paddick’s formula (32, 33):

CI = TVPIV2TV×PIV,(1)

where TV is the target volume, PIV is the prescription isodose volume, and TVPIV is the target volume within the prescription isodose volume.

2.5 Robustness assessment

Isocenter shifts were performed to simulate the error in radiotherapy delivery due to the free breathing of the patient in the TPS to assess plan robustness as demonstrated in Figure 3. Simultaneous shifts of 1 mm, 2 mm, 3 mm, 5 mm, 7 mm, and 10 mm distally in the X (left–right (LR)) and Y (anterior–posterior (AP)) directions, namely, (1,1), (2,2), (3,3), (5,5), (7,7), and (10,10), were applied for each set of plans. That is, for each planning strategy of each patient, six additional plans with different isocenter shifts were created and recalculated to compare with the original plan. Dosimetric parameters, including PTV V100%, V95%, CI, and mean doses to the PTV, lung, liver, and heart, were compared among the six sets of plans with increasing isocenter shifts for the plan robustness assessment.

FIGURE 3
www.frontiersin.org

Figure 3 Isocenter shift geometry for robustness assessment. ISO0 and ISO1 refer to the isocenter whereas PTV0 and PTV1 refer to the relative positions of the PTV before and after the isocenter shift (X,Y), respectively. PTV, planning target volume.

2.6 Data analysis and statistics

All data are shown as mean ± standard deviation (SD). The Friedman test was used for the comparison of dosimetric parameters among five sets of plans. p< 0.05 was defined as statistically significant. If statistical significance was found in the Friedman test, the Bonferroni–Dunn test was used for post-hoc analysis. The corresponding p-values were evaluated with Bonferroni correction; i.e., p< 0.005 was defined as statistically significant. IBM SPSS Statistics 23.0 software (IBM Corporation, Armonk, NY, USA) was used for statistical analyses.

3 Results

The dosimetric distributions of the five planning strategies for one typical patient are shown in the lower panel of Figure 2. The dosimetric parameters of all plans and the corresponding Friedman test results are shown in Table 1. The post-hoc pairwise analysis results for the Friedman tests are included in Supplementary Figure 2. All plans generated were clinically acceptable. Significant differences were found for most examined parameters among the five sets of plans (p< 0.05). The average PTV mean dose, D2cc, and V107% of the IMRTePTV plans were the highest among all plans. However, the liver mean dose and lung-associated parameters were the lowest in IMRTePTV plans.

TABLE 1
www.frontiersin.org

Table 1 Dosimetric comparison of five planning strategies without isocenter shift, including the corresponding p of Friedman tests. .

A demonstration of the dose distribution variation among five plans with increasing isocenter shift can be found in Supplementary Figure 1. Variations of the PTV mean dose, target coverage, and OAR mean doses (mean ± standard deviation) with respect to the isocenter shift are shown in Figure 4. In terms of target coverage and PTV mean dose, IMRTePTV exhibited the highest robustness to the isocenter shift, and then IMRThybrid-flash, IMRTflash, IMRThybrid, and IMRTpure in descending order. V100% and V95% of IMRTePTV remained at 90.5% ± 4.6% and 99.6% ± 0.3% even with a (5,5) shift, which further reduced to 73.4% ± 6.1% and 98.2% ± 2.0% with a (10,10) shift. The mean V100% values of the other strategies with a (1,1) shift were all over 90% but reduced to below 90% with a (3,3) shift. The mean V95% values were above 95% for all strategies except IMRTpure until (5,5), while only IMRTePTV and IMRThybrid-flash maintained this level for (7,7). For (10,10), the mean V95% value of IMRTePTV was still maintained at a high level, which is above 95%. In addition, it should be noted that the PTV mean dose of IMRTePTV was significantly higher than that of the other plans (p< 0.005). Regarding CI, IMRTflash outperformed IMRThybrid-flash initially but ended up at a similar level. Meanwhile, variations of OAR doses did not show any notable differences among the five sets of plans.

FIGURE 4
www.frontiersin.org

Figure 4 Variations in (A) V100%, (B) V95%, (C) PTV mean dose, (D) CI, (E) lung mean dose, (F) heart mean dose, and (G) liver mean dose with increasing isocenter shift for the five planning strategies. PTV, planning target volume; CI, conformity index.

4 Discussion

The purpose of this study was to assess the robustness of five practical planning strategies for breast HFRT after breast-conserving surgery to provide information regarding the choice of treatment strategies. The dosimetric results were compared to confirm the applicability and feasibility of five strategies, and multiple isocenter shifts were used to assess the robustness of positional variations.

Previous studies have demonstrated the importance of plan robustness considerations during proton treatment planning (21). Robust optimization has shown its effectiveness in ensuring target coverage with the existence of inter- and intra-fraction motions in proton therapy (3436). However, the usual practice for motion compensation is adding a margin to the target volume in photon therapy, and robustness is rarely considered. Nonetheless, plan robustness could potentially account for this issue in free-breathing breast radiotherapy with high positional uncertainties (21). In particular, the fraction number in HFRT is reduced from 25–28 to 15–16 compared with conventional fractionation, and the potential hazard from one fraction could bring a more substantial effect to the treatment.

Various imaging guidance and motion management techniques have been developed and utilized for free-breathing breast radiotherapy to reduce motion-induced dosimetric error. Inter- and intra-fraction positioning variations, including setup error, anatomical change, and respiratory motion, are the primary concerns for the robustness evaluation. However, inter- and intra-fraction variations cannot be eliminated with the inevitable anatomical changes. Previous studies have reported various intra- and inter-fraction variations in breast radiotherapy (1418, 36). Lee et al. (14) reported that the median intra-fractional variations for free-breathing right-breast radiotherapy are −0.1 (range −4.2 to 3.6) and 0.6 (range −3.4 to 5.0) mm in the LR and AP directions, and the median inter-fractional variations are −0.7 (range −7.8 to 6.4) and 2.9 (range −16.9 to 9.4) mm in the LR and AP directions, respectively. In this study, considering the intra- and inter-fraction variations and the use of imaging guidance, the isocenter shift was altered from (1,1) to (10,10) for a reasonable evaluation of clinical scenarios. The isocenter shifts were not simulated in the cranial–caudal (CC) direction because the involved techniques focus on the motion compensation in the LR and AP directions. The motion in the CC direction can be accounted for by the CTV–PTV margin.

This study aimed to evaluate the robustness with respect to positional variations of five planning strategies for free-breathing breast HFRT. All plans were clinically acceptable. Based on the results in Figure 4, the target coverage, CI, and mean dose of the PTV for all plans decreased with increasing isocenter shift, while the OAR doses showed an increasing pattern. It can be expected since the displacement of the PTV would potentially lead to the increased exposure of OARs. In terms of PTV dosimetry with increasing isocenter shift, the five planning strategies followed the pattern IMRTePTV, IMRThybrid-flash, IMRTflash, IMRThybrid, and IMRTpure in descending order.

The IMRTpure plans, for which no motion compensation technique was used, resulted in the worst V100%, V95%, PTV mean dose, and CI with increasing isocenter shift as expected. The IMRThybrid plans consisted of 3D-CRT and IMRT fields. The 3D-CRT fields, which contributed 75% of the prescription dose, were manually opened by 2 cm out of the body to provide plan robustness. The IMRT fields can improve target conformity and coverage, as well as OAR sparing, yet the robustness of the IMRT fields was not considered. The IMRTflash technique filled the space of 2 cm outside the body with the fluence of 7 mm within the body using the skin flash tool. However, the approximated fluence was uniformly filled, and the accuracy of the PTV dose distribution with the increasing isocenter shift would be limited. IMRThybrid-flash, as the combination of skin flash and hybrid planning techniques, showed better results than IMRThybrid and IMRTflash. The IMRTePTV plans yielded the best robustness with the use of PTV modification in the CT images and structures for plan optimization. The PTV extended outside of the body contour was assigned with a breast-tissue-equivalent HU value. The PTV coverage can be maintained at a high level because the anatomical changes can be adequately considered.

It should be noted that IMRTePTV did not behave much differently on the variation of OAR doses from the other plans, despite its higher target coverage. With the increase of isocenter shift, even though seemingly more lung, heart, and liver tissues were exposed to the radiation field, this part of the body was not substantially influenced by the applied techniques since the affected dose fluence was primarily out of the body. Therefore, there is no notable difference in the OAR doses among the five sets of plans.

Considering PTV and OAR dosimetry as a whole, the IMRTePTV yielded the best overall robustness to positional variations. However, there are downsides to the IMRTePTV strategy. The planning process is rather challenging. After the plans were optimized on the modified CT images and structures, the new plans were transferred back to the original CT dataset, and the dose was re-calculated. There were many dose hotspots (V107% and V110%) close to the skin. In order to eliminate the dose hotspots, the dose fluence was edited manually with the fluence editing tool until the plans were accepted clinically. The IMRTePTV planning process was more complicated and time-consuming. The main reason for the emergence of dose hotspots in IMRTePTV plans is that the PTV in the final dose calculation is smaller than the PTV in the plan optimization. Although manual fluence modification could allow the plans to meet the clinical protocol, V107% and D2cc of the PTV were still significantly higher compared with the other strategies.

In general, the choice of planning strategies should be determined based on individual circumstances and protocols, and the extent of positional variation would vary among treatment centers depending on patients, motion management methods, and other influencers. In situations of high positional uncertainty (≥5 mm), IMRTePTV should be used to ensure high PTV coverage, but a potentially higher dose of the PTV should be carefully dealt with considering the radiation-induced breast fibrosis (37). For low positional uncertainties (<5 mm), the PTV V95% of IMRThybrid-flash plans maintained above 95% with an isocenter shift of (5,5) as shown in Figure 4. Therefore, the IMRThybrid-flash strategy is recommendable since it is spared from the dosimetric disadvantage of IMRTePTV and the planning process of IMRThybrid-flash is less demanding and time-consuming.

This study has several limitations. First, the dose ratio of IMRT and 3D-CRT for the hybrid planning technique, which might influence the robustness, may not be optimal. To our knowledge, it has not been extensively investigated in previous studies. Second, the intra-fraction positioning error, which can be caused by respiratory motion, anatomical deformation, and radiation-induced tissue responses, could only reflect a local variation rather than a global variation. Therefore, the isocenter shift in this study, which may be considered a worst-case scenario, might amplify the effect of intra-fraction positioning variation in clinical practice.

5 Conclusions

Considering the dosimetric distributions, robustness, and amplitudes of inter- and intra-fraction positioning variations, IMRTePTV should be used to assure target coverage in situations of high positional uncertainty risk (≥5 mm), and IMRThybrid-flash would be adequate for situations with positional uncertainty<5 mm.

Data availability statement

The original contributions presented in the study are included in the article/Supplementary Material. Further inquiries can be directed to the corresponding author.

Ethics statement

Ethical approval was not required for the study involving humans in accordance with the local legislation and institutional requirements. Written informed consent to participate in this study was not required from the participants or the participants’ legal guardians/next of kin in accordance with the national legislation and the institutional requirements.

Author contributions

KC: Conceptualization, Data curation, Methodology, Writing – original draft. WS: Data curation, Formal Analysis, Methodology, Writing – original draft. TH: Data curation, Writing – review & editing. LY: Data curation, Writing – review & editing. MS: Data curation, Writing – review & editing. WX: Data curation, Writing – review & editing. LW: Data curation, Writing – review & editing. YS: Formal Analysis, Writing – original draft. CG: Formal Analysis, Writing – review & editing. XY: Formal Analysis, Writing – review & editing. YL: Data curation, Writing – review & editing. HW: Funding acquisition, Supervision, Validation, Writing – review & editing.

Funding

The author(s) declare financial support was received for the research, authorship, and/or publication of this article. This work was supported by the Jilin Scientific and Technological Development Program (No. YDZJ202201ZYTS685).

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fonc.2023.1259851/full#supplementary-material

References

1. Early Breast Cancer Trialists' Collaborative Group, Darby S, McGale P, Correa C, Taylor C, Arriagada R, et al. Effect of radiotherapy after breast-conserving surgery on 10-year recurrence and 15-year breast cancer death: meta-analysis of individual patient data for 10,801 women in 17 randomised trials. Lancet. (2011) 378:1707–16. doi: 10.1016/S0140-6736(11)61629-2

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Fisher B, Anderson S, Bryant J, Margolese RG, Deutsch M, Fisher ER, et al. Twenty-year follow-up of a randomized trial comparing total mastectomy, lumpectomy, and lumpectomy plus irradiation for the treatment of invasive breast cancer. N Engl J Med (2002) 347:1233–41. doi: 10.1056/NEJMoa022152

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Veronesi U, Cascinelli N, Mariani L, Greco M, Saccozzi R, Luini A, et al. Twenty-year follow-up of a randomized study comparing breast-conserving surgery with radical mastectomy for early breast cancer. N Engl J Med (2002) 347:1227–32. doi: 10.1056/NEJMoa020989

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Haviland JS, Owen JR, Dewar JA, Agrawal RK, Barrett J, Barrett-Lee PJ, et al. The UK Standardisation of Breast Radiotherapy (START) trials of radiotherapy hypofractionation for treatment of early breast cancer: 10-year follow-up results of two randomised controlled trials. Lancet Oncol (2013) 14:1086–94. doi: 10.1016/S1470-2045(13)70386-3

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Whelan TJ, Pignol JP, Levine MN, Julian JA, MacKenzie R, Parpia S, et al. Long-term results of hypofractionated radiation therapy for breast cancer. N Engl J Med (2010) 362:513–20. doi: 10.1056/NEJMoa0906260

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Offersen BV, Alsner J, Nielsen HM, Jakobsen EH, Nielsen MH, Krause M, et al. Hypofractionated versus standard fractionated radiotherapy in patients with early breast cancer or ductal carcinoma in situ in a randomized phase III trial: the DBCG HYPO trial. J Clin Oncol (2020) 38:3615–25. doi: 10.1200/JCO.20.01363

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Marta GN, Riera R, Pacheco RL, Cabrera Martimbianco AL, Meattini I, Kaidar-Person O, et al. Moderately hypofractionated post-operative radiation therapy for breast cancer: Systematic review and meta-analysis of randomized clinical trials. Breast. (2022) 62:84–92. doi: 10.1016/j.breast.2022.01.018

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Krug D, Baumann R, Combs SE, Duma MN, Dunst J, Feyer P, et al. Moderate hypofractionation remains the standard of care for whole-breast radiotherapy in breast cancer: Considerations regarding FAST and FAST-Forward. Strahlenther Onkol. (2021) 197:269–80. doi: 10.1007/s00066-020-01744-3

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Sarria GR, Welzel G, Polednik M, Wenz F, Abo-Madyan Y. Prospective comparison of hypofractionated versus normofractionated intensity-modulated radiotherapy in breast cancer: late toxicity results of the non-inferiority KOSIMA trial (ARO2010-3). Front Oncol (2022) 12:824891. doi: 10.3389/fonc.2022.824891

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Meattini I, Becherini C, Boersma L, Kaidar-Person O, Marta GN, Montero A, et al. European Society for Radiotherapy and Oncology Advisory Committee in Radiation Oncology Practice consensus recommendations on patient selection and dose and fractionation for external beam radiotherapy in early breast cancer. Lancet Oncol (2022) 23:e21–31. doi: 10.1016/S1470-2045(21)00539-8

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Mankinen M, Viren T, Seppala J, Hakkarainen H, Koivumaki T. Dosimetric effect of respiratory motion on planned dose in whole-breast volumetric modulated arc therapy using moderate and ultra-hypofractionation. Radiat Oncol (2022) 17:46. doi: 10.1186/s13014-022-02014-5

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Jacob J, Heymann S, Borget I, Dumas I, Riahi E

Google Scholar

13. Jain P, Marchant T, Green M, Watkins G, Davies J, McCarthy C, et al. Inter-fraction motion and dosimetric consequences during breast intensity-modulated radiotherapy (IMRT). Radiother Oncol (2009) 90:93–8. doi: 10.1016/j.radonc.2008.10.010

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Lee JJB, Lee IJ, Choi Y, Jeon MJ, Jung IH, Lee H. Clinical implications of geometric and dosimetric uncertainties of inter- and intra-fractional movement during volumetric modulated arc therapy for breast cancer patients. Cancers (Basel). (2021) 13:1651. doi: 10.3390/cancers13071651

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Xiao A, Crosby J, Malin M, Kang H, Washington M, Hasan Y, et al. Single-institution report of setup margins of voluntary deep-inspiration breath-hold (DIBH) whole breast radiotherapy implemented with real-time surface imaging. J Appl Clin Med Phys (2018) 19:205–13. doi: 10.1002/acm2.12368

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Delombaerde L, Petillion S, Weltens C, Depuydt T. Spirometer-guided breath-hold breast VMAT verified with portal images and surface tracking. Radiother Oncol (2021) 157:78–84. doi: 10.1016/j.radonc.2021.01.016

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Wang W, Yu T, Xu M, Shao Q, Zhang Y, Li J. Setup error assessment and correction in planar kV image- versus cone beam CT image-guided radiation therapy: A clinical study of early breast cancer treated with external beam partial breast irradiation. Technol Cancer Res Treat (2019) 18:1533033819853847. doi: 10.1177/1533033819853847

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Kugele M, Mannerberg A, Norring Bekke S, Alkner S, Berg L, Mahmood F, et al. Surface guided radiotherapy (SGRT) improves breast cancer patient setup accuracy. J Appl Clin Med Phys (2019) 20:61–8. doi: 10.1002/acm2.12700

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Evans PM, Donovan EM, Partridge M, Childs PJ, Convery DJ, Eagle S, et al. The delivery of intensity modulated radiotherapy to the breast using multiple static fields. Radiother Oncol (2000) 57:79–89. doi: 10.1016/S0167-8140(00)00263-2

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Grégoire V, Mackie TR, De Neve W, Gospodarowicz M, Purdy JA, van Herk M, et al. International commission on radiation units and measurements. ICRU report 83. Prescribing, recording, and reporting photon-beam intensity-modulated radiation therapy (IMRT). J Int Comm Radiat Units Meas (2010) 10:1–106. doi: 10.1093/jicru_ndq009

CrossRef Full Text | Google Scholar

21. Liang X, Bradley JA, Mailhot Vega RB, Rutenberg M, Zheng D, Getman N, et al. Using robust optimization for skin flashing in intensity modulated radiation therapy for breast cancer treatment: A feasibility study. Pract Radiat Oncol (2020) 10:59–69. doi: 10.1016/j.prro.2019.09.017

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Nicolini G, Fogliata A, Clivio A, Vanetti E, Cozzi L. Planning strategies in volumetric modulated arc therapy for breast. Med Phys (2011) 38:4025–31. doi: 10.1118/1.3598442

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Lizondo M, Latorre-Musoll A, Ribas M, Carrasco P, Espinosa N, Coral A, et al. Pseudo skin flash on VMAT in breast radiotherapy: Optimization of virtual bolus thickness and HU values. Phys Med (2019) 63:56–62. doi: 10.1016/j.ejmp.2019.05.010

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Balaji K, Balaji Subramanian S, Sathiya K, Thirunavukarasu M, Anu Radha C, Ramasubramanian V. Hybrid planning techniques for hypofractionated whole-breast irradiation using flattening filter-free beams. Strahlenther Onkol. (2020) 196:376–85. doi: 10.1007/s00066-019-01555-1

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Mayo CS, Urie MM, Fitzgerald TJ. Hybrid IMRT plans–concurrently treating conventional and IMRT beams for improved breast irradiation and reduced planning time. Int J Radiat Oncol Biol Phys (2005) 61:922–32. doi: 10.1016/j.ijrobp.2004.10.033

PubMed Abstract | CrossRef Full Text | Google Scholar

26. von Mehren M, Randall RL, Benjamin RS, Boles S, Bui MM, Ganjoo KN, et al. Soft tissue sarcoma, version 2.2018, NCCN clinical practice guidelines in oncology. J Natl Compr Canc Netw (2018) 16:536–63. doi: 10.6004/jnccn.2018.0025

PubMed Abstract | CrossRef Full Text | Google Scholar

27. McCormick B, Winter K, Hudis C, Kuerer HM, Rakovitch E, Smith BL, et al. RTOG 9804: a prospective randomized trial for good-risk ductal carcinoma in situ comparing radiotherapy with observation. J Clin Oncol (2015) 33:709–15. doi: 10.1200/JCO.2014.57.9029

PubMed Abstract | CrossRef Full Text | Google Scholar

28. McCormick B, Winter KA, Woodward W, Kuerer HM, Sneige N, Rakovitch E, et al. Randomized phase III trial evaluating radiation following surgical excision for good-risk ductal carcinoma in situ: long-term report from NRG oncology/RTOG 9804. J Clin Oncol (2021) 39:3574–82. doi: 10.1200/JCO.21.01083

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Offersen BV, Boersma LJ, Kirkove C, Hol S, Aznar MC, Sola AB, et al. ESTRO consensus guideline on target volume delineation for elective radiation therapy of early stage breast cancer, version 1.1. Radiother Oncol (2016) 118:205–8. doi: 10.1016/j.radonc.2015.12.027

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Kaidar-Person O, Offersen BV, Boersma L, Meattini I, Dodwell D, Wyld L, et al. Tricks and tips for target volume definition and delineation in breast cancer: Lessons learned from ESTRO breast courses. Radiother Oncol (2021) 162:185–94. doi: 10.1016/j.radonc.2021.07.015

PubMed Abstract | CrossRef Full Text | Google Scholar

31. National Cancer Center and National Cancer Quality Control Center. Guideline of target delineatation and treatment planning of adjuvant radiotherapy for breast cancer. Chin J Radiat Oncol (2022) 31:863–78. doi: 10.3760/cma.j.cn113030-20220627-002

CrossRef Full Text | Google Scholar

32. Paddick I. A simple scoring ratio to index the conformity of radiosurgical treatment plans. Tech note. J Neurosurg (2000) 93(Suppl 3):219–22. doi: 10.3171/jns.2000.93.supplement_3.0219

CrossRef Full Text | Google Scholar

33. Seuntjens J, Lartigau EF, Cora S, Ding GX, Goetsch S, Nuyttens J, et al. International commission on radiation units and measurements. ICRU report 91. Prescribing, recording, and reporting of stereotactic treatments with small photon beams. J Int Comm Radiat Units Meas (2014) 14:1–145. doi: 10.1093/jicru_ndx003

CrossRef Full Text | Google Scholar

34. Liu W, Frank SJ, Li X, Li Y, Park PC, Dong L, et al. Effectiveness of robust optimization in intensity-modulated proton therapy planning for head and neck cancers. Med Phys (2013) 40:051711. doi: 10.1118/1.4801899

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Oden J, Toma-Dasu I, Eriksson K, Flejmer AM, Dasu A. The influence of breathing motion and a variable relative biological effectiveness in proton therapy of left-sided breast cancer. Acta Oncol (2017) 56:1428–36. doi: 10.1080/0284186X.2017.1348625

PubMed Abstract | CrossRef Full Text | Google Scholar

36. Liang X, Mailhot Vega RB, Li Z, Zheng D, Mendenhall N, Bradley JA. Dosimetric consequences of image guidance techniques on robust optimized intensity-modulated proton therapy for treatment of breast Cancer. Radiat Oncol (2020) 15:47. doi: 10.1186/s13014-020-01495-6

PubMed Abstract | CrossRef Full Text | Google Scholar

37. National Comprehensive Cancer Network. NCCN clinical practice guidelines in Oncology: Breast Cancer(2018.V4)[EB/OL] (2019). Available at: www.ncc.org/patients.

Google Scholar

Keywords: robustness, breast cancer, hypofractionated radiotherapy, skin flash tool, hybrid planning

Citation: Chen K, Sun W, Han T, Yan L, Sun M, Xia W, Wang L, Shi Y, Ge C, Yang X, Li Y and Wang H (2023) Robustness of hypofractionated breast radiotherapy after breast-conserving surgery with free breathing. Front. Oncol. 13:1259851. doi: 10.3389/fonc.2023.1259851

Received: 17 July 2023; Accepted: 17 October 2023;
Published: 31 October 2023.

Edited by:

Mark Trombetta, Allegheny Health Network, United States

Reviewed by:

Paul Riviere, University of California, San Diego, United States
Seung Hahn, Upstate Medical University, United States

Copyright © 2023 Chen, Sun, Han, Yan, Sun, Xia, Wang, Shi, Ge, Yang, Li and Wang. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Huidong Wang, wang_hd2010@jlu.edu.cn

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.