Skip to main content

ORIGINAL RESEARCH article

Front. Oncol., 05 August 2022
Sec. Gastrointestinal Cancers: Gastric and Esophageal Cancers
This article is part of the Research Topic Premalignant Conditions in the Esophagus and Stomach View all 5 articles

Clinical comparative study of glasses-free 3D and 2D thoracoscopic surgery in minimally invasive esophagectomy

Rongqiang Wei&#x;Rongqiang Wei1†Xinyu Ding&#x;Xinyu Ding1†Zihao Chen&#x;Zihao Chen1†Ning XinNing Xin1Chengdong LiuChengdong Liu1Yunhao FangYunhao Fang1Zhifei XuZhifei Xu1Kenan Huang,*&#x;Kenan Huang1,2*‡Hua Tang*&#x;Hua Tang1*‡
  • 1Department of Minimally Invasive Thoracic Surgery Center, Changzheng Hospital, Naval Medical University, Shanghai, China
  • 2Department of Thoracic Surgery, The First Affiliated Hospital of Soochow University, Suzhou, China

Objective: To investigate the safety and efficacy of glasses-free three-dimensional (3D) thoracoscopic surgery in minimally invasive esophagectomy (MIE).

Methods: The clinical data of 98 patients, including 81 men and 17 women aged 45–77 years, with esophageal squamous cell carcinoma who underwent minimally invasive thoracoscopic esophagectomy from January 2017 to December 2019 [3 years, with clinical follow-up time: 1 year~4 years (2017.01–2020.12)] were retrospectively analyzed. Patients were divided into two groups according to different surgical methods including a glasses-free 3D thoracoscopic group (G-3D group: 38 patients) and a two-dimesional (2D) thoracoscopic group (2D group: 60 patients). The clinical outcome of the two groups were compared.

Results: The operation time of the thoracoscopic part in the G-3D group was significantly shorter than that in the 2D group (P<0.05). The total number of lymph node dissection in the G-3D group was more than that in the 2D group (P<0.05). The thoracic indwelling time, postoperative hospital stay, severe pulmonary infection, arrhythmia, anastomotic leakage, chylothorax, and recurrent laryngeal nerve injury were not significantly different between the two groups (P>0.05). There was also no significant difference between the two groups on the progression-free survival (P>0.05).

Conclusion: Glasses-free 3D thoracoscopic surgery for esophageal cancer is a safe and effective surgical procedure. Compared with 2D thoracoscopic MIE, glasses-free 3D thoracoscopic MIE for esophageal cancer has higher safety, more lymph node dissection, and higher operation efficiency through the optimized surgical operations. We believe that glasses-free 3D thoracoscopy for MIE is worthy of clinical promotion.

Introduction

Esophageal cancer is a common malignant tumor of the digestive tract. When diagnosed, most of the patients are in the advanced stage and lose the chance of surgery, whereas for some early-stage patients, surgery is the preferred treatment procedure (1, 2). With the development of minimally invasive technology, minimally invasive surgery for esophageal cancer becomes more mature and has gradually been recognized (36). From the earliest thoracoscopy combined with laparotomy or laparoscope combined with thoracotomy, the surgery procedure for esophageal cancer radical resection is gradually transited to thoracoscopy combined with laparoscopy. However, the minimally invasive techniques or equipment, such as two-dimensional (2D) thoracoscopy or three-dimensional (3D) thoracoscopy, still have some problems at present. Compared with 2D thoracoscopy, 3D thoracoscopy can improve the comfort of surgeons’ intraoperative performing by being provided with the 3D structure of the target tissues and organs, which can effectively avoid accidental injury and bleeding during the operation (79). However, because of the long operation time, special 3D imaging technology, and the darker visual effect of surgical field during performing 3D thoracoscopic esophagectomy, some surgeons wearing 3D glasses are prone to dizziness, asthenopia, visual ghosting, or other discomfortable symptoms (10, 11). In 2015, the world’s first glasses-free 3D thoracoscopic surgery was completed in Guangzhou, China (12). Glasses-free 3D technology may solve the problems to a certain extent; our study performed domestic glasses-free 3D thoracoscopic and 2D thoracoscopic surgery for minimally invasive esophagectomy (MIE) in our hospital from January 2017 to December 2019. The objective was to evaluate the advantages and disadvantages of domestic glasses-free 3D thoracoscopy in esophageal cancer surgery and provide guidance for clinical practice.

Materials and methods

Patients

The inclusive criteria were as follows: (1) esophageal squamous cell carcinoma diagnosed by endoscopy and confirmed by pathology and (2) clinically evaluated as resectable esophageal cancer, and underwent thoracoscopic combined with laparoscopic esophagectomy; gastroesophageal anastomosis was at the left neck. The exclusion criteria were as follows: (1) patients had received neoadjuvant therapy; (2) patients with tuberculosis, tuberculous pleurisy, pneumonia, or previous chest surgery history; and (3) incomplete case data. Based on the above criteria, a total of 98 patients from January 2017 to December 2019, aged 45–77 years, were included in this study. According to the different thoracoscopic equipment, the patients were divided into two groups: the glasses-free 3D thoracoscopic group (G-3D group, 38 cases, including 30 men and 8 women), and the 2D thoracoscopic group (2D group, 60 cases, including 51 men and 9 women). The operation methods were as follows: the G-3D group was treated with a glasses-free 3D thoracoscopic system (Zhuhai Mingyi Medical Technology Co. Ltd. glasses-free 3D display, smv28f-g01) combined with laparoscopy for minimally invasive esophagectomy; gastroesophageal anastomosis was at left neck. The 2D group was treated with a 2D thoracoscopic system (German Storz 2D thoracoscopic system) combined with laparoscopy for minimally invasive esophagectomy; gastroesophageal anastomosis was at left neck. In the selection of glasses-free 3D or 2D thoracoscopic surgery, we adopt the principle of rotation, with a ratio of approximately 1:2, and try to ensure that the conditions of cases between groups are similar. A flow chart summarizing the selection of eligible patients is shown in Figure 1. The patient characteristics of the two groups are shown in Table 1.

FIGURE 1
www.frontiersin.org

Figure 1 Flow chart summarizing the selection of eligible patients.

TABLE 1
www.frontiersin.org

Table 1 Summary of patient characteristics [x¯ ± s/(%)].

Surgical procedure

The G-3D group was given intravenous-inhalation anesthesia and single lumen intubation. Thoracic part of MIE need to establish artificial pneumothorax of right thoracic cavity to get the surgical field. The surgeon did not need to wear 3D glasses, only wearing a surgical cap with a signal-receiving piece, while assistants need to wear 3D glasses. The patient’s position was left anteversion 30° prone position. One 1-cm incision was made in the 7th intercostal space of the axillary midline as the observation port. The incisions of approximately 1.0, 0.5, and 0.5 cm were made at the fourth intercostal space of the anterior axillary line, the sixth intercostal parascapular intercostal space, and the ninth intercostal space of posterior axillary line, respectively, which were operating ports. The lymph nodes were dissected under the carina, para-esophageal, trachea and bronchus, right recurrent laryngeal nerve (RLN), and left RLN. After thoracoscopic esophagectomy, a thoracic drainage tube [28F polyvinyl chloride (PVC) rigid thoracic drainage tube] was placed into thorax through the observation port. After the thoracic incisions were sutured, the patient was changed to a supine position; then, the stomach was dissociated by laparoscopy. Next, the cervical esophagus was dissociated and severed; the dissociative stomach was taken out through a small incision in the upper abdomen to make a tube stomach. The tube stomach was lifted to the neck through an esophageal bed path for end-to-side esophagogastrostomy (instrument anastomosis). Jejunostomy was performed by the small incision in the upper abdomen; the surgeon and assistants in the 2D group did not need to wear 3D glasses. The anesthesia method and operation procedure were the same as the G-3D group.

To investigate the factors associated with glasses-free 3D and 2D thoracoscopic MIE, we evaluated perioperative clinicopathological data, including age, sex, Body Mass Index (BMI),, American Society of Anesthesiologists (ASA) criteria,, smoking history, drinking history, concomitant disease, tumor location, pathological stage, thoracic operation time, thoracic intraoperative blood loss, surgeon’s uncomfortable feeling (including surgeon dizziness, surgeon asthenopia, and visual ghosting), total number of harvested lymph nodes, thoracic indwelling time, postoperative hospital stay, and postoperative complications(including severe lung infection, arrhythmia, anastomotic leakage, chylothorax, and recurrent laryngeal nerve injury).

Statistical methods

Statistical analysis was performed using SPSS version 22.0 (SPSS Inc., Chicago, IL, USA). Data are presented as mean ± SD. Comparisons were made between the two groups using Student’s t-test for continuous measures and the chi-square test, Fisher’s exact test, or Mann–Whitney U test for categorical variables. Significance was set as a P-value < 0.05.

Results

Both groups of patients were successfully completed the operation.The surgical procedures in all 98 patients were relatively smooth, without conversion to thoracotomy,serious intraoperative bleeding, and intraoperative death cases. About the surgeon’s uncomfortable feeling, including surgeon dizziness, surgeon asthenopia, and visual ghosting, there were no significant differences between the two groups (P > 0.05). The thoracic operation time in the G-3D group was shorter than that in the 2D group [(75.45 ± 11.80) min vs. (88.15 ± 16.08) min, P = 0.000]. The total number of harvested lymph nodes in the G-3D group was more than that in the 2D group [(15.05 ± 2.66) vs. (12.40 ± 1.98), P = 0.000]. There was no significant difference in intraoperative blood loss and postoperative hospital stay between the two groups(P>0.05). There was no significant difference in the thoracic indwelling time, severe lung infection, arrhythmia, anastomotic leakage, chylothorax, and recurrent laryngeal nerve injury between the two groups (P > 0.05). There was no perioperative death in both groups. The outcomes of the two groups are shown in Table 2. The 1-year, 2-year, and 3-year progression-free survival (PFS) of the G-3D group were 89.5%, 57.9%, and 28.9%, respectively; and the 1-year, 2-year, and 3-year PFS of the 2D group were 80.0%, 55.0%, and 30.0%, respectively. There was no significant difference between the two groups on PFS (P>0.05). The survival time of the two groups is shown in Table 3 and Figure 2.

TABLE 2
www.frontiersin.org

Table 2 The outcomes of two groups [x¯ ± s/(%)].

TABLE 3
www.frontiersin.org

Table 3 The survival time of two groups (%).

FIGURE 2
www.frontiersin.org

Figure 2 Kaplan–Meier curves for the glasses-free three-dimensional thoracoscopic group and two-dimensional thoracoscopic group.

Discussion

Whether the glasses-free three-dimensional thoracoscopy could settle the problems that two-dimensional or three dimensional cannot?

Esophageal cancer is one of the most common malignant tumors in China, and its main treatment is still surgical operation. Traditional thoracotomy and laparotomy for radical esophagectomy are limited in clinical application due to the adverse factors such as large trauma, high risks, and many postoperative complications (1315). In recent years, the popularization of a minimally invasive concept, the wide application of endoscopic technology, and the establishment of an evidence-based medicine model have provided a safer and more feasible technical means for esophageal cancer surgery (1619). The commonly used minimally invasive surgical methods include: 2D or 3D thoracoscopy combined with laparoscopic esophagectomy, Da Vinci robotic esophagectomy, and modified inflatable mediastinoscopy combined with laparoscopic esophagectomy (8, 20, 21). At present, 2D thoracoscopy has become the mainstream mode of thoracic surgery; however, due to its lack of depth and space sense, it is relatively easy to cause accidental injury and increase the difficulty of operation. Some domestic hospitals equipped with 3D thoracoscopy can solve this problem well. The surgeon wearing 3D glasses can effectively observe the 3D structure of the target tissues and organs. When performing some fine operations, such as cleaning the lymph nodes in the narrow tissue space, the relationship between the peripheral blood vessels and nerve tissues can be well observed, which can effectively avoid accidental injury and bleeding. However, because of the long operation time and special imaging technology of 3D, some surgeons wearing 3D glasses for a long time are prone to dizziness, asthenopia, visual ghosting, or other discomfortable symptoms during performing thoracoscopic esophagectomy, which affects the overall fluency of the surgical procedures. In addition, 3D glasses are black transparent polarized glasses, which significantly reduce the screen brightness and affect the visual field observation effect (22, 23). The question is: could glasses-free 3D thoracoscopy settle the above problems? In this study, we compared the clinical application of glasses-free 3D thoracoscopy and 2D thoracoscopy in esophageal cancer resection and found that it has some unique advantages.

Glasses-free three-dimensional technology makes the operation more precise, which makes the operation safer

The results showed that there were significant differences in the operation time and number of lymph node dissection between the G-3D group and the 2D group (P < 0.05). In terms of lymph node dissection, at least 12 regional lymph nodes were dissected according to the Union for International Cancer Control (UICC) 7th edition of TNM (Tumor,Node and Metastasis) staging and diagnosis and treatment specifications. The total number of lymph nodes in the G-3D group and 2D group was (15.05 ± 2.66) vs. (12.40 ± 1.98), which met the standard, but the difference was statistically significant (P<0.01).We believe that glasses-free 3D thoracoscopy makes use of its unique depth effect, 3D imaging effect and approximately 20 times magnification visual effect technology to help the surgeon observe the blood vessels and lymph nodes more intuitively and clearly during the operation, which can avoid accidental injury. When dissecting the lymph nodes of the right recurrent laryngeal nerve, the surgeon can carefully identify the recurrent laryngeal nerve and the surrounding vena cava under glasses-free 3D thoracoscopy, which can clean the lymph nodes boldly, avoid injury, and reduce postoperative complications to a certain extent. For some patients with more peripheral fat or pleural adhesion, it has obvious advantages. When dissociating some blood vessels such as the azygous vein and left gastric artery, it can more accurately remove the perivascular fat tissue and omental tissue. For some patients with extensive pleural adhesion, it can separate the adhesions from multiple angles to avoid the injury of lung parenchyma and other main organs. Compared with 2D thoracoscopy, the operation of glasses-free 3D thoracoscopy is easier, and it is easier to grasp, separate, and cut under the thoracoscopy when using the instruments for the first time, which greatly shortens the learning curve and makes the operation of eye–hand cooperation more coordinated (24, 25). Most importantly, glasses-free 3D technology completely gets rid of our commonly used 3D glasses. Before surgery, the chief surgeon only needs to stick the pad with tracking marks on the surgical cap and can capture the surgical field on the glasses-free 3D thoracoscopic display without glasses at all. Moreover, the visual effect is bright and clear, without dullness and obvious ghosting, which minimizes the dizziness and ghosting caused by 3D glasses, making it easier for the chief surgeon to quickly adapt to the 3D effect, reducing discomfort and making the operation safer. About the surgeon’s uncomfortable feeling in this study, the chief surgeon had dizziness in four cases, had asthenopia in four cases, and had visual ghosting in two cases in the G-3D group, but the chief surgeon only had asthenopia in three cases in the 2D group. Although the number of uncomfortable symptoms of the surgeon of the G-3D group was at least twice that of the 2D group, there were no significant differences between the two groups. The chief surgeon said that the above uncomfortable symptoms did not affect the smoothness of the operation. It can be said that glasses-free 3D thoracoscopy is superior to 2D and 3D in some respects.

Glasses-free three-dimensional thoracoscopic esophagectomy does not increase postoperative complications and has similar postoperative survival time to two dimensional

In our study, there was no significant difference in postoperative thoracic drainage time, severe pulmonary infection, arrhythmia, anastomotic leakage, right recurrent laryngeal nerve injury, and other complications between the two groups. The incidence of anastomotic leakage in the two groups (13.3% and 11.4%) was consistent with the reports from many domestic and foreign clinical centers (18, 19, 26). Therefore, glasses-free 3D thoracoscopic esophagectomy did not increase the incidence of postoperative complications. In clinical follow-up, most of the cases were still alive, so we took tumor recurrence or death as the endpoint, that is, we followed up the PFS time of patients. In our study, the 1-year, 2-year, and 3-year PFS of the G-3D group were 89.5%, 57.9%, and 28.9%, respectively; and the 1-year, 2-year, and 3-year PFS of the 2D group were 80.0%, 55.0%, and 30.0%, respectively. The difference between the two groups on PFS was not statistically significant, and long-term outcomes should be followed up.

Some problems of glasses-free three-dimensional thoracoscopic surgery

The glasses-free 3D system requires that a tracking marker be attached to the surgeon’s cap, and the surgeon should stand facing the display screen. Two intelligent cameras above the display screen of the glasses-free 3D system recognize the marker and start working immediately. The cameras can intelligently determine the position of the left and right pupils of the surgeon according to the real-time captured images and then display the 3D images on the screen where the surgeon’s eyes are focused within the range of 1.4–2 m. According to reports, the response time of this glasses-free 3D system is less than 0.01 ms. It can track the eyes of the surgeon at any time, and make immediate adjustments according to the artificial intelligence (AI) algorithm, always ensuring the accuracy, fullness, and stereo of the images. With the help of this system, the surgeon’s vision is wider, the operation area is clearer, the surgeon’s eyes are not as tired as before, and the operation efficiency and accuracy are also improved. However, we also found some problems during the operation of glasses-free 3D thoracoscopic esophagectomy in our study: (1) the proper position of the display screen and surgeon should be adjusted in advance, and the distance should not be too close or too far; otherwise, the surgeon would see an obvious double shadow, which would affect the operation, so it was necessary for the surgeon to choose the best visual effect position and kept the display screen fixed before the operation. (2) During the operation,surgeon interacted with the glasses-free 3D system through a tracking marker on his cap, without wearing 3D glasses, and the surgical assistants needed to wear 3D glasses, so they could not share the glasses-free 3D visual effect. (3) The chief surgeon had dizziness, asthenopia, and visual ghosting in some cases of the G-3D group, but the uncomfortable symptoms did not affect the operation. The above problems may be related to the design and manufacturing issues of glasses-free 3D devices, the stability of the glasses-free 3D system, or the unskilled operation of the mirror assistant. We believe that the glasses-free 3D system still needs to be continuously innovated to meet the clinical needs.

Glasses-free three-dimensional thoracoscopic esophagectomy may have a bright future

With the rapid development of thoracoscopic technology and the continuous renewal of the concept of accelerated rehabilitation surgery, the application of related research and technology in thoracic surgery is getting wider and wider. It is clear that 3D technology brings surgeons a new surgical experience and ultimately benefits patients. However, wearing 3D glasses for a long time will inevitably have some disadvantages, such as dark light, facial discomfort, and easy visual fatigue. Sometimes, the air exhaled by the surgeons forms fog on the glasses. Glasses-free 3D thoracoscopy, which depends on the glasses-free 3D system, makes MIE more precise, can help surgeons to complete the operation more safely and effectively, reduce surgeons’ psychological burden, relieve surgeons’ visual asthenopia, and ensure patients’ safety during the operation. Although the domestic technology still has some defects, we believe that glasses-free 3D thoracoscopy will be an important direction of surgery in the future, which is worthy of clinical application and further exploration.

Conclusions

Our study shows that glasses-free 3D thoracoscopic MIE for esophageal cancer has higher safety, more lymph node dissection, and higher operation efficiency through the optimized surgical operations. Glasses-free 3D thoracoscopic surgery for esophageal cancer is a safe and effective surgical procedure. However, it must be pointed out that the study is a retrospective study, and its conclusion has certain limitations due to historical or selective factors. We believe that glasses-free 3D thoracoscopy for MIE is worthy of clinical promotion and further research should be initiated and implemented.

Data availability statement

The original contributions presented in the study are included in the article/Supplementary Material. Further inquiries can be directed to the corresponding authors.

Ethics statement

Written informed consent was obtained from the individual(s) for the publication of any potentially identifiable images or data included in this article.

Author contributions

TH and HN conceived and designed the study. WR, DX, CZ, XN, LC, and FY collected the data. WR, DX, and XZ analyzed the data. WR wrote the first draft. All authors contributed to the article and approved the submitted version.

Funding

This study was supported by the Project of youth program of shanghai health and family planning commission(20154y0040), the project of general program of national natural science foundation (81470213),youth program of national natural science foundation (81402449).

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fonc.2022.959484/full#supplementary-material

References

1. Chen W-Q, Zheng R, Baade P, Zhang S, Zeng H, Bray F, et al. Cancer statistics in China. CA Cancer J Clin (2016) 2016(2):115–32. doi: 10.3322/caac.21338

CrossRef Full Text | Google Scholar

2. Siegel RL, Miller KD, Fuchs HE, Jemal A. Cancer statistics, 2022. CA Cancer J Clin (2022) 72(1):7–33. doi: 10.3322/caac.21708

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Nguyen NT, Hinojosa MW, Smith BR, Chang KJ, Gray J, Hoyt D. Minimally invasive esophagectomy: lessons learned from 104 operations. Ann Surg (2008) 248(6):1081–91. doi: 10.1097/SLA.0b013e31818b72b5

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Safranek P, Cubitt J, Booth M, Dehn TC. Review of open and minimal access approaches to oesophagectomy for cancer. Brit J Surg (2010) 97(12):1845–53. doi: 10.1002/bjs.7231

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Mungo B, Lidor AO, Stem M, Molena D. Early experience and lessons learned in a new minimally invasive esophagectomy program. Surg Endosc (2016) 30(4):1692–8. doi: 10.1007/s00464-015-4343-2

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Haverkamp L, Seesing MF, Ruurda JP, Boone J, Hillegersberg RV. Worldwide trends in surgical techniques in the treatment of esophageal and gastroesophageal junction cancer. Dis Esophagus (2017) 30(1):1–7. doi: 10.1111/dote.12480

CrossRef Full Text | Google Scholar

7. Sakata S, Watson MO, Grove PM, Stevenson AR. The conflicting evidence of three-dimensional displays in laparoscopy: A review of systems old and new. Ann Surg (2016) 263(2):234–9. doi: 10.1097/sla.0000000000001504

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Charalabopoulos A, Lorenzi B, Kordzadeh A, Tang C-B, Kadirkamanathan S, Jayanthi NV. Role of 3D in minimally invasive esophagectomy. Langenbecks Arch Surg (2017) 402(3):555–61. doi: 10.1007/s00423-017-1570-0

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Fergo C, Burcharth J, Pommergaard HC, Kildebro N, Rosenberg J. Three-dimensional laparoscopy vs 2-dimensional laparoscopy with high-definition technology for abdominal surgery: a systematic review. Am J Surg (2017) 213(1):159–70. doi: 10.1016/j.amjsurg.2016.07.030

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Li Z, Li JP, Qin X, Xu BB, Han YD, Liu SD, et al. Three-dimensional vs two-dimensional video assisted thoracoscopic esophagectomy for patients with esophageal cancer. World J Gastroenterol (2015) 21(37):10675–82. doi: 10.3748/wjg.v21.i37.10675

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Yang CL, Wang W, Mo LL, Zhang L, Peng GL, Yu ZW, et al. Short-term outcome of three-dimensional versus two-dimensional video-assisted thoracic surgery for benign pulmonary diseases. Ann Thorac Surg (2016) 101(4):1297–302. doi: 10.1016/j.athoracsur.2015.10.042

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Li M. The world's first radical resection for lung cancer using glasses-free 3D thoracoscope was completed in guangzhou. J Thorac Dis (2015) 3(15):223. doi: 10.3978/j.issn.2305-5839.2015.09.06

CrossRef Full Text | Google Scholar

13. Luketich JD, Pennathur A, Awais O, Levy RM, Keeley S, Shende M, et al. Outcomes after minimally invasive esophagectomy: review of over 1000 patients. Ann Surg (2012) 256(1):95–103. doi: 10.1097/SLA.0b013e3182590603

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Ai B, Zhang Z, Liao Y. Laparoscopic and thoracoscopic esophagectomy with intrathoracic anastomosis for middle or lower esophageal carcinoma. J Thorac Dis (2014) 6(9):1354–7. doi: 10.3978/j.issn.2072-1439.2014.07.38

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Kalff MC, Fransen LFC, de Groot EM, Gisbertz SS, Nieuwenhuijzen GAP, Ruurda JP, et al. Long-term survival after minimally invasive versus open esophagectomy for esophageal cancer: A nationwide propensity-score matched analysis. Ann Surg (2020). doi: 10.1097/sla.0000000000004708

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Thirunavukarasu P, Gabriel E, Attwood K, Kukar M, Hochwald SN, Nurkin SJ. Nationwide analysis of short-term surgical outcomes of minimally invasive esophagectomy for malignancy. Int J Surg (2016) 25:69–75. doi: 10.1016/j.ijsu.2015.11.023

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Yerokun BA, Sun Z, Yang CJ, Gulack BC, Speicher PJ, Adam MA, et al. Minimally invasive versus open esophagectomy for esophageal cancer: A population-based analysis. Ann Thorac Surg (2016) 102(2):416–23. doi: 10.1016/j.athoracsur.2016.02.078

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Gottlieb-Vedi E, Kauppila JH, Malietzis G, Nilsson M, Markar SR, Lagergren J. Long-term survival in esophageal cancer after minimally invasive compared to open esophagectomy: A systematic review and meta-analysis. Ann Surg (2019) 270(6):1005–17. doi: 10.1097/sla.0000000000003252

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Gottlieb-Vedi E, Kauppila JH, Mattsson F, Lindblad M, Nilsson M, Lagergren P, et al. Long-term survival in esophageal cancer after minimally invasive esophagectomy compared to open esophagectomy. Ann Surg (2021). doi: 10.1097/sla.0000000000004645

CrossRef Full Text | Google Scholar

20. Ali AM, Bachman KC, Worrell SG, Gray KE, Perry Y, Linden PA, et al. Robotic minimally invasive esophagectomy provides superior surgical resection. Surg Endosc (2021) 35(11):6329–34. doi: 10.1007/s00464-020-08120-3

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Kandagatla P, Ghandour AH, Amro A, Popoff A, Hammoud Z. Long-term outcomes after robotic-assisted ivor Lewis esophagectomy. J Robot Surg (2022) 16(1):119–25. doi: 10.1007/s11701-021-01219-2

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Shao W, Yin W, Wang W, Zhang X, Peng G, Chen X, et al. Glasses-free three-dimensional endoscopic bronchoplasty, arterioplasty, and angioplasty of the superior vena cava for the radical treatment of right middle upper lung cancer. J Thorac Dis (2016) 8(3):608–11. doi: 10.21037/jtd.2016.01.57

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Li X, Cui F, Xing T, Huang Y, Deng J, Hao Z, et al. Glasses-free 3D versus 2D video-assisted thoracoscopic thymectomy: a single-center short-term comparative study. Ann Transl Med (2019) 7(23):761. doi: 10.21037/atm.2019.11.96

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Özsoy M, Kallidonis P, Kyriazis I, Panagopoulos V, Vasilas M, Sakellaropoulos GC, et al. Novice surgeons: do they benefit from 3D laparoscopy? Lasers Med Sci (2015) 30(4):1325–33. doi: 10.1007/s10103-015-1739-0

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Padin EM, Santos RS, Fernández SG, Jimenez AB, Fernández SE, Dacosta EC, et al. Impact of three-dimensional laparoscopy in a bariatric surgery program: Influence in the learning curve. Obes Surg (2017) 27(10):2552–56. doi: 10.1007/s11695-017-2687-5

PubMed Abstract | CrossRef Full Text | Google Scholar

26. Raymond D. Complications of esophagectomy. Surg Clin N Am (2012) 92(5):1299–313. doi: 10.1016/j.suc.2012.07.007

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: glasses-free 3D display system, thoracoscopy, minimally invasive esophagectomy (MIE), esophageal squamous cell carcinoma, thoracic surgery

Citation: Wei R, Ding X, Chen Z, Xin N, Liu C, Fang Y, Xu Z, Huang K and Tang H (2022) Clinical comparative study of glasses-free 3D and 2D thoracoscopic surgery in minimally invasive esophagectomy. Front. Oncol. 12:959484. doi: 10.3389/fonc.2022.959484

Received: 01 June 2022; Accepted: 12 July 2022;
Published: 05 August 2022.

Edited by:

Fernando A. M. Herbella, Federal University of São Paulo, Brazil

Reviewed by:

Hirotoshi Kikuchi, Hamamatsu University School of Medicine, Japan
Mariano Menezes, Pontifical Catholic University of Parana, Brazil

Copyright © 2022 Wei, Ding, Chen, Xin, Liu, Fang, Xu, Huang and Tang. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Hua Tang, tangh_mits@163.com; Kenan Huang, renrenhuanghe@163.com

These authors contributed to the work equally and share first authorship

These authors have contributed equally to this work

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.