Abstract
Recent mobile brain/body imaging (MoBI) techniques based on active electrode scalp electroencephalogram (EEG) allow the acquisition and real-time analysis of brain dynamics during active unrestrained motor behavior involving whole body movements such as treadmill walking, over-ground walking and other locomotive and non-locomotive tasks. Unfortunately, MoBI protocols are prone to physiological and non-physiological artifacts, including motion artifacts that may contaminate the EEG recordings. A few attempts have been made to quantify these artifacts during locomotion tasks but with inconclusive results due in part to methodological pitfalls. In this paper, we investigate the potential contributions of motion artifacts in scalp EEG during treadmill walking at three different speeds (1.5, 3.0, and 4.5 km/h) using a wireless 64 channel active EEG system and a wireless inertial sensor attached to the subject’s head. The experimental setup was designed according to good measurement practices using state-of-the-art commercially available instruments, and the measurements were analyzed using Fourier analysis and wavelet coherence approaches. Contrary to prior claims, the subjects’ motion did not significantly affect their EEG during treadmill walking although precaution should be taken when gait speeds approach 4.5 km/h. Overall, these findings suggest how MoBI methods may be safely deployed in neural, cognitive, and rehabilitation engineering applications.
Introduction
The development of non-invasive mobile brain/body imaging (MoBI) techniques based on active electroencephalography (EEG) synchronized with motion sensing (; ) and advanced signal processing methods to identify and remove physiological and non-physiological artifacts (; ; ; ) promise to allow neuroscientists and engineers to investigate the neural dynamics in brain networks during natural (i.e., unconstrained environments) cognition and action.
Recent advances in non-invasive EEG to detect brain activation patterns signaling movement intent during locomotive and non-locomotive tasks (, ; ; ; ) and during assisted walking using in lower extremity wearable exoskeletons (; ; ; ; ) offer the potential to elucidate the cortical contributions to gait and the harnessing of such gait-related neural activity for brain-machine interfaces (BMI) to wearable robots for assistive and therapeutic applications ().
However, little is known about the motor circuits for walking in humans. It is generally agreed that central pattern generators are important in the control of walking; however, supraspinal networks, including the cortex, must be critical as a result of the complexity of locomotive and non-locomotive tasks in activities of daily living. Several studies have shown electrocortical activity coupled to gait cycle phase during treadmill walking (; ), and robotic-assisted treadmill walking (). That primary motor cortex carries information about bipedal locomotion has been directly proven by the work of , who demonstrated that chronic recordings from ensembles of cortical neurons in primary motor (M1) and primary somatosensory (S1) cortices can be used to predict the kinematics of bipedal walking in rhesus macaques.
Neural decoding studies based on scalp EEG have shown that linear and angular kinematics (, ; ) and surface electromyography (EMG) activity can be inferred from scalp EEG during treadmill or robot-assisted walking (). Moreover, recent studies have deployed neural classifiers based on scalp EEG signals to detect cortical involvement immediately before gait (e.g., gait intention detection; ; ) or non-locomotion tasks such as sit-to-stand and stand-to-sit (). Closed-loop BMI based on EEG have shown the feasibility of using brain waves to control powered exoskeleton for over ground in individuals with spinal cord injury () and in robotic-assisted treadmill walking ().
Unfortunately, EEG signals are susceptible to physiological and non-physiological artifacts, including motion artifacts, which may compromise the decoding of gait and the interpretation of the neural signals relevant to bipedal locomotion. Methods have been developed to identify and remove such artifacts from the EEG signals (; ; ), but the efficacy of such methods has been questioned recently (; ). Given that brain activity and the level of artifactual components may vary with walking speed, experimental setup, quality of the instrumentation, tasks, and expertise of the experimenters, published data remains inconclusive. Thus, the purpose of this study was to examine the potential contributions of motion artifacts in scalp EEG during treadmill walking at three different speeds, as in . The experimental setup was designed according to good measurement practices using state-of-the-art commercial off-the-shelf instruments, and the measurements were analyzed using time-frequency analysis and non-parametric spectral estimation approaches.
Methods
Participants
Three able-bodied males and one able-bodied female (ages 26–33) participated in this study. All participants provided voluntary informed consent and performed study procedures that were approved by the Institutional Review Board at the University of Houston.
Experimental Procedure and Data Acquisition
The experimental protocol followed closely to that reported in . Participants were instructed to walk on a treadmill at three fixed speeds of 1.5, 3.0, and 4.5 km/h for a minimum of 3-min sessions for each speed. Whole scalp active 64-channel EEG data were collected (battery-operated BrainAmpDC amplifiers with actiCap system, Brain Products GmbH, Munich, Germany) and labeled in accordance with the extended 10–20 international system. EEG data were online referenced to channel FCZ, while electrode impedances were maintained below 10 kΩ. A wireless interface (MOVE system, Brain Products GmbH) transmitted the data to the amplifier, which applied low-pass analog filters set from DC-1000 Hz, and the EEG signals were digitized at 1 kHz using a BrainAmp DC amplifier linked to BrainVision Recorder software version 1.10.
A light-weight wireless Magnetic, Angular Rate, and Gravitational (MARG) sensor (Opal IMU sensors; APDM, Inc.; Portland, OR) was placed on the forehead to record triaxial magnetic, gyroscopic, and acceleration data at a sampling rate of 1280 Hz with an output rate of 128 Hz at 14 bits resolution (bandwidth of 50 Hz) during treadmill walking. The MARG sensor specifications were: weight (<22 g with battery), dimensions (48.4 L × 36.1 W × 13.4 H mm), latency (30 ms), accelerometer range and noise (±6 g; 0.0012 m/s2/√Hz), gyroscope range and noise (±2000 deg/s; 0.05 deg/s/√Hz), magnetometer range and noise (±6 Gauss; 0.5 mGauss/√Hz). Figure 1A shows a photo of the experimental setup with the subject wearing the EEG cap and Opal sensor. Careful placement of the MARG sensor on the participant’s forehead, as in , ensured no physical interference with the EEG electrodes that could potentially lead to perturbation or distortions of the EEG signals. For comparison, Figure 1B depicts the experimental setup used by (reproduced here with permissions from the author and original publisher), which may have potentially interfered with the EEG electrode recordings and affected the inertial mass properties of the subject’s head (note that mass of the accelerometer and other technical specifications of this custom setup were not provided in their published manuscript). Flexible contact switches were placed on the heel and toe of both feet to be used as footswitches (FS4 Contact Switch Assembly with DataLOG, Biometrics Ltd., Cwmfelinfach, Gwent, UK), to identify the timing of the heel-strike and toe-off phases of gait at a sampling rate of 1 kHz. EEG, MARG, and footswitch data were time-locked using an external trigger circuit to mark the start and stop of the walking periods. The trigger signal was transmitted wirelessly using the Pololu Wixel RF transmitter/receiver (Pololu Corporation, Las Vegas, NV, USA). Figure 1C shows representative raster plots depicting recorded raw EEG (midline channels FZ, CZ, PZ, and OZ as well as channels C1, C2, and T8), and gravity-compensated components of the 3D acceleration (x: gravity; y: toward subject’s left shoulder; z: direction of walking) for the four participants walking in the treadmill at 1.5, 3.0, and 4.5 km/h.
FIGURE 1
Signal Processing and Spectrotemporal Analysis
Pre-processing
The magnetic, acceleration, and gyroscopic data from the MARG sensor were transformed from the sensor’s reference frame to Earth-fixed frame, and were then used to produce a gravity-compensated acceleration output signal (
Spectral Analysis
The spectra of the three EEG signals and the adjusted (normalized magnitude) acceleration were analyzed by performing a fast Fourier transform (FFT command in Matlab). Default parameters were used (i.e., FFT length was set to the length of the signal rounded up to the next power of 2). The single-sided spectra were analyzed for each channel for each speed and for each subject. These methods were adopted to facilitate comparison with findings from
Event-Related Spectral Perturbation Analysis
The average deviation from baseline spectral power during the gait cycle, i.e., the ERSP (
Wavelet Coherence Analysis
We measured the coherence via a wavelet analysis to analyze frequency correlation between each EEG channel and the acceleration measured by the head-mounted MARG sensor. The raw EEG and acceleration data were similarly detrended, but the time-frequency analysis was performed with the Crosswavelet and Wavelet Coherence package (
Artifact Subspace Reconstruction
As an ancillary analysis, we repeated the above steps after performing an automated artifact rejection process known as Artifact Subspace Reconstruction (ASR) (
Results
Frequency Spectra of EEG and Accelerometer
Single-sided spectra computed using the fast Fourier transform are shown in Figure 2 for subject S3 for the three EEG channels (CZ, OZ, and T8), and for the x-axis (pointing in the direction of gravity) of vertical head acceleration at three speeds of 1.5, 3.0, and 4.5 km/h. (Sample traces for three full gait cycles for the raw and ASR-processed EEG and acceleration channels are shown in Figure 1C). Plots for the other three subjects are included as Supplementary Material as the data is representative across all subjects. The spectra of the EEG channels in our study exhibit commonly found 1/f properties, but absent are large amplitude spikes dominating the spectra which correspond to the stepping frequency of walking (0.47 Hz for 1.5 km/h, 0.76 Hz for 3.0 km/h, 0.93 Hz for 4.5 km/h) or any harmonics thereof, contrary to the findings reported in Figure 1 of
FIGURE 2

Fast fourier transform (FFT) of EEG channels and downward acceleration showing frequency spectra for subject S3 at each speed; tick marks on top of plots indicate harmonics of the fundamental stepping frequency.
Event-Related Spectral Perturbation Analysis
Average deviations in spectral power throughout the normalized gait cycle are shown in the ERSP plots in Figure 3 for one individual subject (S3) and for grouped subject data. Individual plots for the other subjects are included as Supplementary Material. The x-axis vertical acceleration channel, oriented toward gravity, shows striking intra-stride broadband oscillations, particularly for the two faster speeds (3.0 and 4.5 km/h), spanning continuously (except for an interruption around 60 Hz, likely due to electrical noise) from 20 Hz up to at least 80 Hz. For the individual subject data from S3, we see a decrease in power after the heel strikes followed by a rise during the swing phase (after RTO and LTO). This pattern gets shifted or reversed when averaged across all subjects at 3.0 km/h (and in some cases of other individual subjects at other speeds, see Supplementary Material) with the decrease in power occurring after the swing phases. The oscillations coinciding with gait phase still remain a consistent feature of the acceleration ERSP, but such features are generally absent when comparing with the EEG ERSPs, even when notably reducing the scale of the color bar. Individually, S3 shows some oscillations in power at low frequencies (less than 10 Hz), but these are not seen in the group averaged data.
FIGURE 3

(A) Event-related spectral perturbations (ERSPs) of EEG channels and magnitude acceleration averaged across all gait cycles for one subject (S3) and all subjects’ averaged data at each speed. (B) ERSP plots of EEG channels and acceleration after processing EEG with Artifact Subspace Reduction.
The above analysis was repeated after applying ASR to the raw EEG data (see Figure 3B), with the acceleration ERSPs remaining unchanged. In the group-averaged data, ASR attenuated the changes in spectral power seen in the temporal channels, as alternating regions of dark blue and dark red became negligible. This reduction was not evident in the individual data (S3), and some frequencies showed increased power changes after ASR, particularly in EEG channels at 4.5 km/h.
Wavelet Coherence Between EEG and Accelerometer Signals
We computed the wavelet coherence between the three EEG channels (CZ, OZ, and T8) and the accelerometer, and display continuous time data for one subject (S3, Figure 4) and group-averaged data averaged for all gait cycles (Figure 5). The Crosswavelet and Wavelet Coherence package (
FIGURE 4

Wavelet coherence of EEG channels with x-axis of acceleration for sample 10 s of walking data for subject S3 at each speed, (A) before and (B) after processing with Artifact Subspace Reduction. Frequency is scaled logarithmically on the y-axis and is limited to the delta band range of EEG (up to 4 Hz). Vertical black lines indicate onset of RHS; horizontal black lines indicate the frequency of stepping. The arrows indicate the relative phase relationship (in-phase pointing right, anti-phase pointing left, and EEG leading acceleration by 90° pointing straight down), and are only shown for regions with coherence greater than 0.5. Thick black contour lines indicate regions are significant against red noise at the 5% level.
FIGURE 5

Wavelet coherence of delta band EEG with x-axis of acceleration averaged across all subjects’ gait cycles at each speed (A) before and (B) after processing with Artifact Subspace Reduction. Vertical black lines indicate onset of gait cycle phase; horizontal black lines indicate the frequency of stepping. The arrows indicate the relative phase relationship (in-phase pointing right, anti-phase pointing left, and EEG leading acceleration by 90° pointing straight down), and are only shown for regions with coherence greater than 0.5.
In the individual subject data (S3 shown in Figure 4; additional subjects are included in the Supplementary Materials), regions of significant coherence (at the 5% level determined using Monte Carlo generated noise, marked by thick black boundaries) generally do not span across the gait cycles on a consistent basis, but appear sparsely in small blots. At speeds of 4.5 km/h, long regions of significant coherence span continuously across multiple gait cycles in channels CZ and OZ for S3 with phase angles close to -180° around 0.17–0.27 Hz. Consistent generalizations are hard to discern for all of the subjects, but with the exception of S4 (see Supplementary Materials), significant coherence tends to be seen only at the two faster speeds.
In the group- and gait cycle-averaged data (Figure 5), coherence does not seem to vary significantly with time within the averaged gait cycle. The magnitude of coherence in the delta band exceeds 0.5 only at speeds greater than 1.5 km/h. At 3.0 km/h, there is strong coherence (i.e., greater than 0.5) in the CZ and T8 channels between the narrow band of 0.68–0.89 Hz with phase angles varying from 23.9 to 43.4° (mean 33.9°); this band is centered around the stepping frequency for this speed (0.76 Hz), and is likely an artifactual component, especially with the positive phasic relationship. Each channel shows strong coherence at 4.5 km/h between the frequencies of 1.57–2.32 Hz, and also between 0.83 and 1.11 Hz for T8, similar to the coherence at 3.0 km/h; the phase angles were all mostly positive but close to zero for CZ and OZ, calculated to range from -13.6 to 32.7° and -4.3 to 21.9° for the bands in CZ and OZ respectively; for T8, the lower band had positive phase angles between 39.9 and 64.6° and the upper band had negative phase angles toward the end of the gait cycle after the RTO phase from (-28.8)-(-2.02)°.
When ASR was applied, any evidence of delta band coherence disappeared in the averaged group data (Figure 5B) except at 4.5 km/h for CZ at the same frequency ranges with the phase angles mostly unaltered. The effects of ASR are quite varied on an individual subject basis: Figure 4B shows fewer and smaller regions of significant coherence in S3 after ASR for speeds of 3.0 km/h or slower, except for some low frequency regions below 0.1 Hz, while the opposite effect is seen at the fast walking speed. The rest of the individual subject data and group-averaged data for ASR are included in Supplementary Figures S3 and S4.
Discussion
Negligible Effects of Head Motion on EEG Signals During Treadmill Walking
The main finding of this study is that head motion unlikely contaminated the EEG recordings at treadmill gait speeds of 1.5, 3.0, and 4.5 km/hr. This finding is in contrast with a recent study by
Several discrepancies in the experimental setup and recording techniques may explain these discrepancies. First, it is likely that the experimental setup used in
A recent study by
We extended our analysis to focus on the potential effects of motion artifacts within the delta band (0.1–4 Hz) of EEG, given that this range has been practically used in decoding studies (
Artifact Subspace Reduction and Other Means of Removing Artifacts
While the main purpose of this study was to understand the extent to which motion artifacts can contaminate raw EEG signals during walking without any processing, we performed our analysis of the EEG data both with and without an automated artifact rejection algorithm known as the ASR method.
We found ASR to be most beneficial in attenuating the large amplitude deviations of the ERSP at speeds of 4.5 km/h (Figure 3) and in reducing regions of significant coherence (Figure 5) at speeds greater than 3.0 km/h; the artifact content at slower walking speeds seems negligible enough to not require additional processing for artifact removal. We note also that sit-to-stand and stand-to-sit actions are likely to be more prone to motion artifacts due to excessive gross movement during these actions.
For other MoBI applications that involve excessive movement, including fast treadmill walking or running, there may a stronger tendency for motion artifact to be introduced into the EEG, thereby necessitating optimized artifact removal algorithms to minimize these effects and salvage the EEG signal.
This study focused on the possible mechanical artifacts induced in the EEG by the movement of cables due to head motion during treadmill walking. This is not to disregard other potential contributors to artifacts that are not movement-related, but to emphasize that non-physiological artifacts can generally be accounted for and minimized with proper instrumentation and measuring practices (
Conclusion
In this study, we analyzed head acceleration data from a forehead-mounted inertial sensor along with active EEG recordings during treadmill walking at three different fixed gait rates. To assess for the potential effects of head motion-related artifacts on the signal quality of the EEG, we analyzed the spectral content of the EEG and acceleration data to inspect for common harmonics in the spectra and computed the ERSPs to measure the deviations from baseline in spectral power across the average gait cycle. We found that the patterns in these measurements are not similar between individual EEG channels and the acceleration, in that strong harmonics in the Fourier spectra and strong spectral gait-synced spectral deviations were found for acceleration but these harmonics were generally absent or negligible in the scalp EEG at gait speeds no faster than 3.0 km/h with minor evidence of motion artifacts in the 4.5 km/h condition in the case of peripheral electrodes. Additional wavelet coherence analysis focusing on the delta band frequency range (0.1–4 Hz) showed a lack of continuous and consistent periods of significant coherence between the head motion and the EEG. Furthermore, comparisons of these findings with results from ASR-cleaned EEG signals suggest that motion artifacts did not likely affect the EEG signals. We primarily found ASR to reduce peak values of spectral deviations in the ERSPs and remove regions of strong coherence for speeds up to 3.0 km/h for the group data. For experiments involving faster walking speeds, ASR may be useful to help mitigate the contamination of motion artifacts. While
Statements
Author contributions
KN collected the data, performed the analysis, wrote the manuscript, and created the figures for the paper. JV supervised the experiment, provided suggestions for the analysis, and reviewed the manuscript.
Acknowledgments
We would like to thank Yongtian He, No-Sang Kwak, and Keun-Tae Kim for their assistance in collecting the data. This study was funded by NIH Award NINDS R01NS075889.
Conflict of interest
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Supplementary material
The Supplementary Material for this article can be found online at: http://journal.frontiersin.org/article/10.3389/fnhum.2015.00708
FIGURE S1 | Fast fourier transform (FFT) of EEG channels and downward acceleration showing frequency spectra for each subject at each speed.FIGURE S2 | (A) Event-related spectral perturbations (ERSPs) of EEG channels and magnitude acceleration averaged across all gait cycles for each subject at each speed. (B) ERSP plots of EEG channels and acceleration after processing EEG with Artifact Subspace Reduction.FIGURE S3 | Wavelet coherence of EEG channels with x-axis of acceleration for sample 10 s of walking data for each subject at each speed, (A) before and (B) after processing with Artifact Subspace Reduction. Frequency is scaled logarithmically on the y-axis and is limited to the delta band range of EEG (up to 4 Hz). Vertical black lines indicate onset of Right Heel Strikes (RHS); horizontal black lines indicate the frequency of stepping. The arrows indicate the relative phase relationship (in-phase pointing right, anti-phase pointing left, and EEG leading acceleration by 90° pointing straight down), and are only shown for regions with coherence greater than 0.5. Thick black contour lines indicate regions are significant against Brownian noise at the 5% level.FIGURE S4 | Wavelet coherence of delta band EEG with x-axis of acceleration averaged across all gait cycles for each subject at each speed (A) before and (B) after processing with Artifact Subspace Reduction. Vertical black lines indicate gait cycle phase; horizontal black lines indicate the frequency of stepping. The arrows indicate the relative phase relationship (in-phase pointing right, anti-phase pointing left, and EEG leading acceleration by 90° pointing straight down), and are only shown for regions with coherence greater than 0.5.References
1
BarlowJ. S. (1986). “Artifact processing (rejection and minimization) in EEG data processing,” in Clinical Applications of Computer Analysis of EEG and other Neurophysiological Signals: Handbook of Electroencephalography and Clinical Neurophysiology, edsLopes da SilvaF. H.Storm van LeeuwenW.RémondA. (Amsterdam: Elsevier), 15–65.
2
BrowningR. C.EmilyA. B.JessicaA. H.RodgerK. (2006). Effects of obesity and sex on the energetic cost and preferred speed of walking.J. Appl. Physiol.100390–398. 10.1152/japplphysiol.00767.2005
3
BuleaT. C.PrasadS.KilicarslanA.Contreras-VidaJ. L. (2014). Sitting and standing intention can be decoded from scalp EEG recorded prior to movement execution.Front. Neurosci.8:376. 10.3389/fnins.2014.00376
4
CastermansT.DuvinageM.CheronG.DutoitT. (2014). About the cortical origin of the low-delta and high-gamma rhythms observed in EEG signals during treadmill walking.Neurosc. Lett.561166–170. 10.1016/j.neulet.2013.12.059
5
CroftR. J.BarryR. J. (2000). Removal of ocular artifact from the EEG: a review.Neurophysiol. Clin.305–19. 10.1016/S0987-7053(00)00055-1
6
De VosM.GandrasK.DebenerS. (2014). Towards a truly mobile auditory brain-computer interface: exploring the P300 to take away.Int. J. Psychophysiol.9146–53. 10.1016/j.ijpsycho.2013.08.010
7
DebenerS.MinowF.EmkesR.GandrasK.de VosM. (2012). How about Taking a Low-Cost, Small, and Wireless EEG for a Walk?Psychophysiology491617–1621. 10.1111/j.1469-8986.2012.01471.x
8
DelormeA.MakeigS. (2004). EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis.J. Neurosci. Methods1349–21. 10.1016/j.jneumeth.2003.10.009
9
DoA. H.WangP. T.KingC. E.ChunS. N.NenadicZ. (2013). Brain-computer interface controlled robotic gait orthosis.J. Neuroeng. Rehabilit.10:111. 10.1186/1743-0003-10-111
10
FatourechiM.BashashatiA.WardR. K.BirchG. E. (2007). EMG and EOG artifacts in brain computer interface systems: a survey.Clin. Neurophysiol.118480–494. 10.1016/j.clinph.2006.10.019
11
FischB. J.SpehlmannR. (1999). Fisch and Spehlmann’s EEG Primer: Basic Principles of Digital and Analog EEG. Available at: http://www.researchgate.net/publication/203917877_Fisch_and_Spehlmann’s_EEG_primer_Basic_principles_of_digital_and_analog_EEG
12
FitzsimmonsN. A.LebedevM. A.PeikonI. D.NicolelisM.A.L. (2009). Extracting kinematic parameters for monkey bipedal walking from cortical neuronal ensemble activity.Front. Integr. Neurosci.3:3. 10.3389/neuro.07003.2009
13
GoncharovaI. I.McFarlandD. J.VaughanT. M. and Wolpaw J. R. (2003). EMG contamination of EEG: spectral and topographical characteristics.Clin. Neurophysiol.1141580–1593. 10.1016/S1388-2457(03)00093-2
14
GramannK.FerrisD. P.GwinJ.MakeigS. (2014). Imaging natural cognition in action.Int. J. Psychophysiol. Organ. Psychophysiol.9122–29. 10.1016/j.ijpsycho.2013.09.003
15
GrinstedA.MooreJ. C.JevrejevaS. (2004). Application of the cross wavelet transform and wavelet coherence to geophysical time series.Nonlinear Process. Geophys.11561–566. 10.5194/npg-11-561-2004
16
GwinJ. T.GramannK.MakeigS.FerrisD. P. (2010). Removal of movement artifact from high-density EEG recorded during walking and running.J. Neurophysiol.1033526–3534. 10.1152/jn.00105.2010
17
GwinJ. T.GramannK.MakeigS.FerrisD. P. (2011). Electrocortical activity is coupled to gait cycle phase during treadmill walking.Neuroimage541289–1296. 10.1016/j.neuroimage.2010.08.066
18
HeY.NathanK.VenkatakrishnanA.RovekampR.BeckC.OzdemirR.et al (2014). “An integrated neuro-robotic interface for stroke rehabilitation using the NASA X1 powered lower limb exoskeleton,” in Proceedings of the Conference Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Chicago, IL.
19
JiangN.GizziL.Mrachacz-KerstingN.DremstrupK.FarinaD. (2015). A brain-computer interface for single-trial detection of gait initiation from movement related cortical potentials.Clin. Neurophysiol.126154–159. 10.1016/j.clinph.2014.05.003
20
KilicarslanA.PrasadS.GrossmanR. G.Contreras-VidalJ. L. (2013). High accuracy decoding of user intentions using eeg to control a lower-body exoskeleton.Conf. Proc. IEEE Eng. Med. Biol. Soc.35606–5609. 10.1109/EMBC.2013.6610821
21
KlineJ. E.HuangH. J.SnyderK. L.FerrisD. P. (2015). Isolating gait-related movement artifacts in electroencephalography during human walking.J. Neural Eng.12:046022. 10.1088/1741-2560/12/4/046022
22
KlineJ. E.PoggenseeK.FerrisD. P. (2014). Your brain on speed: cognitive performance of a spatial working memory task is not affected by walking speed.Front. Hum. Neurosci.8:288. 10.3389/fnhum.2014.00288
23
LauT. M.GwinJ. T.FerrisD. P. (2014). Walking reduces sensorimotor network connectivity compared to standing.J. Eng. Rehabilit.11:14. 10.1186/1743-0003-11-14
24
LinsO. G.PictonT. W.BergP.SchergM. (1993). Ocular artifacts in eeg and event-related potentials i: scalp topography.Brain Topogr.651–63. 10.1007/BF01234127
25
MakeigS. (1993). Auditory event-related dynamics of the eeg spectrum and effects of exposure to tones.Electroencephalogr. Clin. Neurophysiol.86283–293.
26
MakeigS.GramannK.JungT.-P.SejnowskiT. J.PoiznerH. (2009). Linking brain, mind and behavior.Int. J. Psychophysiol.7395–100. 10.1016/j.ijpsycho.2008.11.008
27
MullenT.KotheC.ChiY. M.OjedaA.KerthT.MakeigS.et al (2013). Real-time modeling and 3D visualization of source dynamics and connectivity using wearable EEG.Conf. Proc. IEEE Eng. Med. Biol. Soc.20132184–2187. 10.1109/EMBC.2013.6609968
28
NolanH.WhelanR.ReillyR. B. (2010). FASTER: fully automated statistical thresholding for EEG artifact rejection.J. Neurosci. Methods192152–162. 10.1016/j.jneumeth.2010.07.015
29
NoureldinA.KaramatT. B.GeorgyJ. (2013). Fundamentals of Inertial Navigation, Satellite-Based Positioning and Their Integration.Berlin: Springer Science & Business Media.
30
O’ReganS.MarnaneW. (2013). Multimodal detection of head-movement artefacts in EEG.J. Neurosci. Methods218110–120. 10.1016/j.jneumeth.2013.04.017
31
PetersenT. H.Willerslev-OlsenM.ConwayB. A.NielsenJ. B. (2012). The motor cortex drives the muscles during walking in human subjects.J. Physiol.590(Pt 10), 2443–2452. 10.1113/jphysiol.2012.227397
32
PresaccoA.ForresterL. W.Contreras-VidalJ. L. (2012). Decoding intra-limb and inter-limb kinematics during treadmill walking from scalp electroencephalographic (EEG) signals.IEEE Trans. Neural Syst. Rehabil. Eng.20212–219.
33
PresaccoA.GoodmanR.ForresterL.Contreras-VidalJ. L. (2011). Neural decoding of treadmill walking from noninvasive electroencephalographic signals.J. Neurophysiol.1061875–1887. 10.1152/jn.00104.2011
34
RaethjenJ.GovindanR. B.BinderS.ZeunerK. E.DeuschlG.StolzeH. (2008). Cortical representation of rhythmic foot movements.Brain Res.123679–84. 10.1016/j.brainres.2008.07.046
35
ReisP. M. R.HebenstreitF.GabsteigerF.von TscharnerV.LochmannM. (2014). Methodological aspects of EEG and body dynamics measurements during motion.Front. Hum. Neurosci.8:156. 10.3389/fnhum.2014.00156
36
RongF.Contreras-VidalJ. L. (2006). Magnetoencephalographic artifact identification and automatic removal based on independent component analysis and categorization approaches.J. Neurosci. Methods157337–354. 10.1016/j.jneumeth.2006.04.024
37
SeeberM.SchererR.WagnerJ.Solis-EscalanteT.Müller-PutzG. R. (2014). EEG beta suppression and low gamma modulation are different elements of human upright walking.Front. Hum. Neurosci.8:485. 10.3389/fnhum.2014.00485
38
SeverensM.NienhuisB.DesainP.DuysensJ. (2012). Feasibility of measuring event related desynchronization with electroencephalography during walking.Conf. Proc. IEEE Eng. Med. Biol. Soc.20122764–2767. 10.1109/EMBC.2012.6346537
39
SörnmoL.LagunaP. (2005). Biomedical Engineering?: Bioelectrical Signal Processing in Cardiac and Neurological Applications.Burlington, MA: Academic Press. Available at: http://site.ebrary.com/lib/uhmain/docDetail.action?docID=10206421
40
SweeneyK. T.WardT. E.McLooneS. F. (2012). Artifact removal in physiological signals–practices and possibilities.IEEE Trans. Inf. Technol. Biomed.16488–500. 10.1109/TITB.2012.2188536
41
UrigüenJ. A.Garcia-ZapirainB. (2015). EEG artifact removal-state-of-the-art and guidelines.J. Neural Eng.12:031001. 10.1088/1741-2560/12/3/031001
42
VeluP. D.de SaV. R. (2013). Single-trial classification of gait and point movement preparation from human EEG.Front. Neurosci.7:84. 10.3389/fnins.2013.00084
43
VenkatakrishnanA.FranciscoG. E.Contreras-VidalJ. L. (2014). Applications of brain-machine interface systems in stroke recovery and rehabilitation.Curr. Phys. Med. Rehabil. Rep.293–105. 10.1007/s40141-014-0051-4
44
WagnerJ.Solis-EscalanteT.GrieshoferP.NeuperC.Müller-PutzG.SchererR. (2012). Level of participation in robotic-assisted treadmill walking modulates midline sensorimotor EEG rhythms in able-bodied subjects.Neuroimage631203–1211. 10.1016/j.neuroimage.2012.08.019
45
WillisJ.NelsonA.RiceJ.BlackF. W. (1993). The topography of muscle activity in quantitative EEG.Clin. Electroencephalogr.24123–126. 10.1177/155005949302400310
Summary
Keywords
electroencephalography, EEG, artifacts, walking
Citation
Nathan K and Contreras-Vidal JL (2016) Negligible Motion Artifacts in Scalp Electroencephalography (EEG) During Treadmill Walking. Front. Hum. Neurosci. 9:708. doi: 10.3389/fnhum.2015.00708
Received
18 September 2015
Accepted
17 December 2015
Published
13 January 2016
Volume
9 - 2015
Edited by
Richard A. P. Roche, Maynooth University, Ireland
Reviewed by
Maide Bucolo, University of Catania, Italy; Maarten De Vos, University of Oldenburg, Germany
Updates

Check for updates
Copyright
© 2016 Nathan and Contreras-Vidal.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Kevin Nathan, kcnathan@uh.edu
Disclaimer
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.