Skip to main content

ORIGINAL RESEARCH article

Front. Neurol., 13 November 2024
Sec. Endovascular and Interventional Neurology
This article is part of the Research Topic Diagnostic and Predictive Roles of Computational Cardiovascular Hemodynamics in the Management of Cardiovascular Diseases View all 6 articles

Hemodynamic assessment of intracranial atherosclerotic stenosis: comparison between invasive non-hyperemic pressure ratio and angiography-derived quantitative flow ratio

Xiaohui Wang&#x;Xiaohui Wang1Yang Bian&#x;Yang Bian2Rongju ZhangRongju Zhang1Haojing ZhuHaojing Zhu1Junjie YangJunjie Yang3Ruiling WangRuiling Wang4Xinfeng LiuXinfeng Liu1Bin LvBin Lv1Xiangyu CaoXiangyu Cao1Wei DaiWei Dai1Zhibin SunZhibin Sun5Jing JingJing Jing3Zhihua Du
Zhihua Du1*Shengyuan Yu
Shengyuan Yu1*Jun Wang
Jun Wang1*
  • 1Department of Neurology, The First Medical Center, Chinese PLA General Hospital, Beijing, China
  • 2Health One Departments, The Second Medical Center, Chinese PLA General Hospital, Beijing, China
  • 3Department of Cardiology, The First Medical Center, Chinese PLA General Hospital, Beijing, China
  • 4Department of Clinical Laboratory, The Third Medical Center, Chinese PLA General Hospital, Beijing, China
  • 5Department of Mathematics, College of Science, Hebei Agricultural University, Baoding, China

Objectives: To evaluate the diagnostic accuracy of the quantitative flow ratio (QFR) for hemodynamic exploration of intracranial atherosclerotic stenosis, using the invasive cerebrovascular pressure ratio (CVPR) and resting full-cycle ratio (RFR) as reference standards.

Materials and methods: Patients with symptomatic unifocal intracranial atherosclerotic stenosis were included. The CVPR was defined as the ratio of the proximal and distal pressures. All patients underwent angioplasty under general anesthesia. The QFR was calculated based on digital subtraction angiography. Using the CVPR as a reference, we compared its correlation with the QFR across different degrees and locations of stenosis.

Results: The CVPR and QFR were measured in 34 vessels of 32 patients. The QFR demonstrated a high correlation and excellent agreement(r = 0.8227, p < 0.001) with the CVPR in distal stenosis before intervention. In the subgroup with diameter stenosis >80%, the QFR showed a high correlation (r = 0.8812, p < 0.001) with the CVPR. In the anterior circulation subgroup, the QFR showed an excellent correlation (r = 0.9066, p < 0.001) with the CVPR. In the posterior circulation subgroup, the QFR showed a high correlation with the CVPR (r = 0.7706, p < 0.001). Diameter stenosis rates showed a moderate negative correlation with the CVPR.

Conclusion: There was a strong correlation between the QFR and wire-based CVPR, especially for anterior circulation lesions before intervention. The QFR may serve as a predictive factor for evaluating hemodynamic changes in intracranial atherosclerotic stenosis.

1 Introduction

Intracranial atherosclerotic stenosis (ICAS) is the most common reason of ischemic stroke worldwide, especially in Asian populations, with a higher incidence than that in other ethnic groups. In Asian populations, ICAS accounts for approximately 30–54% of ischemic cerebral infarctions and transient ischemic attacks (TIAs) compared with 5–10% in White populations and 15–29% in Black populations (15). The risk of recurrent stroke and death is increased by 25–30% in symptomatic intracranial arterial stenosis (6). In China, the morbidity and mortality of stroke remain high throughout the year (7). The recurrence rate 30 days after cerebral infarction in patients with intracranial artery stenosis is up to 15% after active drug treatment (8).

Therefore, it is important to provide patients with better evaluation, optimized screening, and accurate identification. In addition to the degree of artery stenosis and collateral compensation, hemodynamic estimation is vital for ICAS. At present, the clinical evaluation of blood flow is mainly related to perfusion examinations, including computed tomography perfusion (CTP) examination and perfusion-weighted magnetic resonance imaging. These examinations play important roles in facilitating hemodynamic evaluation and enhancing the efficacy of percutaneous transluminal angioplasty and stenting for intracranial artery stenosis, particularly of the middle cerebral artery (9, 10). However, the utility of CTP in the assessment of the posterior circulation is limited, and one study has shown that CTP has limited diagnostic utility in cases involving acute ischemia of the posterior circulation (11). For cases with bilateral lesions in the intracranial arteries, the accuracy of these perfusion tests may be affected by the lack of good contrast, precluding direct assessment of cerebral hemodynamics in ICAS. To address these limitations, Miao et al. (12) and Liu et al. (13) evaluated changes in cerebrovascular hemodynamics in patients with ICAS using a pressure guidewire in the cerebral vasculature, which verified its safety and feasibility. No serious adverse events associated with the device or procedure occurred.

Fractional flow reserve (FFR) using an invasive pressure guidewire has become one of the gold standards for evaluating hemodynamic deficiency of coronary artery stenosis (14). Studies have shown that resting indices derived from the pressure measurements at rest, without the administration of adenosine, are also independent measures of ischemia (15, 16), thereby reducing the need for hyperemic agents that could cause adverse reactions. In fact, some validation studies have demonstrated that non-hyperemic pressure ratios (NHPRs), including the resting full-cycle ratio (RFR) and instantaneous wave-free ratio (iFR), have similar diagnostic performance to FFR in identifying ischemia-causing coronary lesions (17, 18). The RFR is a non-hyperemic pressure-derived index based on unbiased identification of the lowest distal arterial pressure (Pd)/proximal arterial pressure (Pa) within the entire cardiac cycle and has been shown to be equivalent to the iFR in clinical practice (19). However, hemodynamic assessments of cerebrovascular intravascular pressure are currently lacking. In this regard, some studies used a pressure guidewire to measure the Pa and Pd of intracranial arterial stenosis, and geometric directories based on angiography were correlated with pressure gradient indices between the proximal and distal ends of the stenosis (20).

The quantitative flow ratio (QFR) is a novel method for estimating the fractional flow rate using computational fluid dynamics computations of the coronary arteries from the angiograph. This measurement does not require hyperemic agents or invasive pressure wires, and can virtually evaluate FFR (21). Previous studies from China, Europe, and Japan have verified the feasibility and accuracy of QFR assessment in determining the hemodynamic significance of coronary stenoses, in contrast to FFR measurement using invasive pressure wires (22, 23). However, there is a lack of relevant comparative cerebrovascular studies to verify their accuracy. Therefore, this study aimed to evaluate the diagnostic accuracy of QFR for hemodynamic exploration of ICAS, using the invasive cerebrovascular pressure ratio (CVPR) and RFR as reference standards, in which the pressure ratio between the distal and proximal of the stenosis is different from FFR, because the intracranial artery is far from the heart, the pressure ratio is not equivalent to the flow ratio. So we defined the measured ratio as CVPR (the ratio of the proximal and distal pressure), which is also termed as FF (fractional flow) in the relevant literature.

2 Materials and methods

2.1 Study design and patients

This study enrolled patients with ICAS who underwent cerebral angiography and NHPR measurements using a pressure guidewire between February 2021 and April 2022. The inclusion criteria were as follows: (1) age 18 to 80 years, (2) presence of recurrent TIA or ischemic stroke within 6 months, (3) stenosis rate of 50–99% confirmed by cerebral angiography, (4) onset of TIA or ischemic stroke symptoms >21 days, and (5) modified Rankin Scale (mRS) score ≤ 3. The exclusion criteria were as follows: (1) tandem lesion with concurrent stenosis or occlusion; (2) any form of intracranial hemorrhage within 3 months; (3) severe coronary atherosclerotic cardiopathy intolerance under general anesthesia; and (4) patients with intracranial hydrocephalus, arteriovenous malformation, aneurysm, or tumor. This study was approved by the Ethics Committee of Chinese PLA General Hospital, and patients or their legally authorized representative provided written informed consent. To limit the effect that the degree of stenosis might have on collateral compensation, all patients were classified into subgroups based on percentage diameter stenosis (DS%) by cerebral angiography: DS% ≤ 80% subgroup and DS% > 80% subgroup.

2.2 Cerebrovascular angiography and measurement of invasive NHPRs

General anesthesia was administered to all patients. Access was established through conventional neurointerventional surgery for ICAS, and an appropriate type of intermediate catheter or guide catheter was advanced to the proximal end of the target artery. A microcatheter was used to guide a 0.014-inch pressure wire (C12008; Abbot St. Jude Medical, Minneapolis, MN, United States) to measure the intracranial pressure of the proximal and distal lesions of the stenosis. CVPR and RFR were calculated without hyperemia.

Pd was defined as the pressure at the distal end of the stenosis and Pa was the pressure on the intermediate catheter; both were measured. The CVPR and RFR were measured and calculated automatically using the Abbott Vascular instrument with QUANTIEN™ System (C12787; St. Jude Medical, Minnesota, United States). The CVPR, a parameter close to the FFR, was calculated as Pd/Pa. RFR was defined as the point with the lowest Pd/Pa ratio during the whole cardiac cycle. RFR was calculated by instantaneous Pd/Pa measuring continuously around five cardiac cycles.

2.3 Quantitative flow ratio assessment

The calculation of the QFR was performed using a prototype software by Pulse Medical Imaging Technology made in Shanghai (AngioPlus Core) by an experienced analyst blind to the QFR data (24). The following steps were primarily followed for the computation. (a) Two image projections of digital subtraction angiography (DSA) were selected for analysis of the primary vessel and associated lateral branches, acquired greater than or equal to 25° apart and displayed presenting the minimum overlap and least stenosis. (b) Contour lines were drawn automatically and manually corrected when appropriate. The key frames with a clear outline were selected as the analysis frames, with side branch diameters of ≥1.0 mm and a clear outline at the narrow segment. (c) The reference diameter function was reconstructed with a reduced size at the bifurcations, and performed according to the Murray fractal law (25). (d) The hyperemic flow velocity was modeled based on the pressure drop calculation from the empirical low velocity and the hydrodynamic equation (26), assuming a blood density of 1,060 kg/m3 and viscosity of 0.0035 kg/(ms) (27). In addition, QFR was calculated from the mean empirical flow velocities of the intracranial arteries (0.60 m/s for middle cerebral artery and 0.40 m/s for vertebrobasilar artery and internal carotid artery) (28). QFR combines morphological and functional features to calculate a pressure-derived index across the stenosis area, allowing for a comprehensive assessment of severity (Figure 1).

Figure 1
www.frontiersin.org

Figure 1. Schematic of QFR calculation process.

2.4 Statistical analysis

The statistical analyses were completed using SPSS version 26.0, Python of Anaconda Navigator (version 1.9.7, Anaconda), and GraphPad Prism 9 (Software, California, Belgium). Correlation analyses between QFR, RFR, and CVPR were performed using the Pearson correlation coefficient method. The goodness of fit R2, the correlation coefficient (r), and p-value were used as important indicators to evaluate linear correlation. The Bland–Altman plot was used to assess the consistency of the two continuous variable measurements. Statistical significance was defined as p < 0.05.

As there is no recognized critical value for CVPR in ICAS, two empirical critical values based on the FFR threshold for coronary heart disease (CVPR = 0.75, CVPR = 0.80) were established to investigate the diagnostic efficiency of QFR and the percentage diameter of stenosis based on the value of coronary artery stenosis. Computation with the area under the curve (AUC) of the receiver operating characteristic was to assess the predictive accuracy.

3 Results

In this study, 32 patients with 34 cerebrovascular lesions were included. A single lesion was examined in 30 patients, and two lesions examined in two patients.

3.1 Baseline clinical characteristics

The average patient age was 58.7 ± 6.2 years; 29 patients were male, 37.5% were diabetic, and 84.4% were suffering from new ischemic stroke or TIA. There were 12 patients with anterior circulation lesions (nine in the intracranial segment of the internal carotid artery and three in the middle cerebral artery) and 22 with posterior circulation lesions (eight in the intracranial segment of the vertebral artery and 14 in the basilar artery; Table 1). All patients underwent percutaneous transluminal angioplasty consisting of balloon dilatation alone or with stenting, and CVPR measurement before and after interventional surgery.

Table 1
www.frontiersin.org

Table 1. Characteristics of the patients at baseline.

An illustrative example is shown in Figure 2. A 52-year-old man was diagnosed with a TIA and severe basilar artery stenosis. Cerebral angiography revealed a severe lesion in the basilar artery (Figure 2A). In the distal stenosis lesion, the CVPR and RFR measured by invasive pressure wire were 0.73 and 0.66, respectively (Figure 2B). QFR measured at the same location was 0.68 (Figure 2C), with a clear pressure ratio decrease. Post basilar artery angioplasty, the stenosis was significantly improved (Figure 2D). The CVPR and RFR values increased to 0.92 and 0.91 (Figure 2E), and the QFR value recovered significantly to 0.94 (Figure 2F).

Figure 2
www.frontiersin.org

Figure 2. Typical case: A 52-year-old male was admitted due to intermittent dizziness with blurred vision in the right eye for 20 days. Panel (A) showed severe basilar artery stenosis (yellow arrow) before surgery; (B) the CVPR and RFR values of the distal stenosis measured using an invasive pressure wire were 0.73 and 0.66; and (C) the calculated QFRwas 0.68 in the same lesion. The bottom row presented the postoperative figure, and panel (D) showed an obvious improvement in stenosis; (E) the CVPR and RFR values were increased to 0.92 and 0.91; and (F) QFR was noted to have recovered significantly to 0.94.

3.2 Correlation between quantitative flow ratios and cerebrovascular pressure ratios

In the preoperative evaluation of intracranial atherosclerotic stenosis, QFR showed a high correlation (r = 0.8227, p < 0.001) with CVPR (Figure 3A). Prominent consistency was demonstrated between CVPR and QFR (95% limits of agreement: −0.15 to 0.17, Figure 3B). After interventional surgery, QFR revealed a moderate correlation (r = 0.4975, p = 0.004) with CVPR (Figure 3C). RFR showed an excellent correlation (r = 0.9817, p < 0.001) with CVPR, the difference around the fitted regression line was distributed by residual plot presents (Standard Deviation: (SD) = 0.02318, Figure 4A).

Figure 3
www.frontiersin.org

Figure 3. Correlation and consistency between QFR and CVPR. Before interventional surgery, strongly positive correlation (A) and agreement (B) is observed between QFR and CVPR. (C) After interventional surgery, a weakly positive correlation is observed between QFR and CVPR. The light blue area represents predicted “QFR” for a confidence interval of 99%.

Figure 4
www.frontiersin.org

Figure 4. A strong, positive correlation between CVPR and RFR. Analysis diagram of a linear correlation is in the figure above, and the figure below is the residual error diagram. (A) Correlation between QFR or CVPR and diameter stenosis rate. (B) A weekly negative correlation between CVPR and DS%. (C) Medium negative correlation between QFR and DS%.

3.2.1 Subgroup analysis based on different vessels and degree of stenosis

Among groups categorized by degrees of DS, the DS% >80 subgroup showed a high correlation between QFR and CVPR (r = 0.8812, p < 0.001; Figure 5A). The DS% ≤80% subgroup showed a moderate correlation between QFR and CVPR (r = 0.6242, p = 0.007; Figure 5B). Among the different vessel lesions groups, the anterior circulation subgroup showed an excellent correlation between QFR and CVPR (r = 0.9066, p < 0.001; Figure 5C). The posterior circulation subgroup showed a high correlation between QFR and CVPR (r = 0.7706, p < 0.001; Figure 5D).

Figure 5
www.frontiersin.org

Figure 5. Correlation analysis of QFR and CVPR among different subgroups. Panels (A) and (B) present different degrees of diameter stenosis (DS): (A) DS% >80 and (B) DS% ≤80%. Panels (C) and (D) represent different lesions: (C) the anterior circulation (middle cerebral artery and internal carotid artery in intracranial segment) and (D) posterior circulation (basilar artery and vertebral artery in intracranial segment).

3.2.2 Subgroup analysis between DS% and CVPR and QFR

DS rates showed a moderate inverse correlation with CVPR (r = −0.4196, p = 0.013), and the difference around the fitted regression line was distributed by residual plot (SD = 0.07753; Figure 4B). DS rates showed a moderate negative correlation with QFR (r = −0.5365, p = 0.001) and the residual plot around the fitted regression line (SD = 0.07208; Figure 4C).

3.3 Diagnostic efficiency of QFR

Regarding the cut-off quantitative value of coronary artery lesions, a CVPR value of <0.75 was considered to cause significant hemodynamic disturbance. The area under the curve for QFR was higher than that for DS% (0.873, 95% CI 0.759 to 0.988 vs. 0.616, 95% CI 0.422 to 0.811, p = 0.004), indicating QFR has significantly higher diagnostic efficiency than DS% (Figure 6A). The results were obtained when assuming a CVPR of <0.80 as the critical value (0.956, 95% CI 0.894 to 0.999 vs. 0.696, 95% CI 0.435 to 0.956, p = 0.051; Figure 6B), which showed no statistical significance, but a trend that QFR can better reflect the degree of hemodynamic disturbance was observed.

Figure 6
www.frontiersin.org

Figure 6. Contrast of diagnostic efficiency between QFR and DS% by ROC analyses. (A) ROC curves for QFR and DS% when CVPR <0.75 and (B) ROC curves when CVPR <0.8.

4 Discussion

In this study, we adapted the calculation method of the coronary FFR to measure intracranial atherosclerotic stenosis lesions using NHPRs, including CVPR and RFR. In some studies on coronary stenosis (29), NHPRs, such as the ratio at rest in coronary stenosis in the distal to proximal coronary pressure (Pd/Pa), were more accurate than the FFR. Compared with coronary FFR, CVPR is not completely representative of the fractional flow in cerebrovascular diseases. CVPR measurements can only represent pressure values at different positions of the intracranial artery, and the change in vascular pressure is an important hemodynamicparameters. Hemodynamic indicators have garnered increasing attention when compared to DS% and clinical symptoms. Cerebral perfusion examinations, although commonly employed in clinical practice, can be adversely influenced by various subjective and objective factors. For instance, Transcranial Doppler (TCD) requires a high level of professional expertise from inspectors, while CTP or PWI may not accurately evaluate hemodynamic changes in bilateral lesions. Furthermore, these methods demonstrate poor accuracy in assessing perfusion within the posterior circulation lesions due to the complexity of rich autoregulation and collateral circulation (30). Thus, we contend that direct pressure measurement upstream and downstream the stenosis serves as the most intuitive representation and an indicator of hemodynamic abnormalities in the target vessel.

4.1 Circulation further complicate the cerebral hemodynamic status

In previous studies on coronary artery disease, the agreement and correlation between the QFR and FFR have been well verified, and QFR has become widely used for guiding coronary intervention operations (31). In the cerebrovascular field of intracranial atherosclerotic stenosis, few studies have compared QFR and invasive pressure ratio measurements. The classical QFR calculation is widely used for assessing coronary artery stenosis, but there is a notable shortage of related calculations in the field of cerebrovascular disease. Measurement of the QFR in the intracranial arteries is still being explored. The new QFR calculation method considers the side branches that are closer to natural bifurcation physiology. Instead of assuming linear tapering, a function of step-down reference diameter using Murray bifurcation fractal law is used to reconstruct more accurate reference vessel dimensions (24). The QFR calculation in this paper has been modified to account for the blood flow velocity of cerebral arteries, which may introduce certain limitations. Our team is attempting to optimize the measurements based on 3D-DSA images and artificial intelligence calculations, aiming to find a more suitable measurement method for intracranial arteries.

The measurement and calculation of CVPR and QFR were completed before and after surgery, which more comprehensively covered the different vascular conditions in our study. Most lesions demonstrated severe stenosis before surgery, whereas, after surgery, mild or no stenosis was observed. The results showed a good degree of agreement and correlation between non-invasive QFR and invasive CVPR, especially preoperatively, when the correlation of QFR and CVPR was more significant. Compared with CVPR measurement, non-invasive QFR measurement has more advantages in clinical application, as patients with CVPR measurement require general anesthesia, and a pressure guidewire in the intracranial artery increases the probability of surgical risk. QFR measurement could be used to calculate the pressure ratio of the distal stenosis lesion with high reliability based on cerebral angiography, determining whether stenosis leads to hemodynamic variation. The analysis after the interventional operation of ICAS showed that the correlation between QFR and CVPR was significantly reduced, which might be related to intima damage in the target arterial lumen and the different extents of dissection that appeared during the operation. Although the level of stenosis was obviously improved, it was repaired slowly with a topical vascular wall; therefore, QFR could not completely represent hemodynamic alterations.

In addition, collateral compensation of the intracranial arteries was considered one of the factors affecting the flow in stenotic lesions. The more severe the stenosis, the more obvious the existence of collateral compensation (32, 33). Therefore, a subgroup analysis was performed according to different degrees of stenosis, with >80% defined as absolute severe stenosis and 60–80% as possible severe stenosis. In the subgroup with stenosis >80%, the R-value was 0.8812 in the correlation comparison between QFR and CVPR, while in the group with <80% stenosis, it was 0.6242, indicating that the correlation between QFR and CVPR was stronger in patients with more severe stenosis. This indicates that the more severe the stenosis, the stronger the correlation between QFR and CVPR, which might be a higher reference for clinical impact.

We also performed a subgroup analysis of the different parts of the intracranial arteries. Middle cerebral and internal carotid arteries in the intracranial segments were assigned to the anterior circulation group, and vertebral and basilar arteries in the intracranial segments were assigned to the posterior circulation group. The results revealed a correlation between the QFR and CVPR, which was larger in the anterior circulation. This might be attributed to the different mechanisms in the collateral circulation between the anterior and posterior circulations; in the anterior circulation, the complete circle of Willis is more common than that in the posterior circulation (34, 35). Analysis of different subgroups suggested that QFR and CVPR were moderately correlated at different degrees of stenosis and lesion locations. Non-invasive QFR could better reflect pressure changes in intracranial atherosclerotic stenosis, indirectly indicating whether the lesion was associated with hemodynamic disorders.

Regarding anatomical structure, we analyzed the correlation between CVPR or QFR and the DS% of ICAS. We revealed a negative correlation in individuals with different DS%, and the degree of QFR correlation was slightly higher. This indicates that the more severe the stenosis, the lower the pressure fraction at the distal stenosis, which might imply a greater hemodynamic change in the lesion. From the analysis of the strength of correlation, both r values were below 0.55, suggesting that not all patients with severe stenosis had a lower pressure ratio. It is possible that other factors, such as the influence of collateral circulation within the intracranial arteries, may play a role.

While investigating non-invasive pressure measurement, we also measured RFR without injecting hyperemic drugs. RFR has been recognized and widely used in percutaneous coronary intervention (PCI) guidance for coronary artery stenosis (36, 37). In previous studies on coronary artery diseases, the quantitative value of the RFR was lower than that of the FFR. However, the RFR and CVPR data in our study were in high agreement, which could be because the CVPR data were also measured using non-hyperemic conditions. The calculation methods are based on a coronary artery model. Our team considered that RFR measurements alone could not explain this issue, and compared with CVPR measurements, additional RFR measurements were not necessary. In addition to QFR, other hemodynamic indicators have been established using non-invasive approaches, including computational fluid dynamics modeling and signal intensity ratio based on the quantitative and time-of-flight magnetic resonance angiography (3842), with promising results. However, all of these have their own limitations. The automatic delineation of artery contours by an artificial intelligence algorithm facilitated by 3D-DSA angiography images might provide more accurate data for intraoperative application. We proposed that the measurement of the direct translesional pressure ratio can potentially have a significant impact. To further investigate this, our neurointerventional team has initiated both a prospective cohort study and a comparative study with quantitative analysis between nuclear magnetic perfusion and CVPR. These studies are expected to provide stronger evidence regarding ICAS. Intracranial pressure measurement of invasive non-hyperemic pressure ratios is a direct pressure value on specific vascular location by using pressure-wire, and the pressure ratio was one of the important indicators of hemodynamics but still could not reflect the reserve function and complete state of cerebral blood flow. The calculation of QFR was in the preliminary phase in cerebrovascular evaluation, and the measured method could be provided a portion of hemodynamic reference value. In the future, artificial intelligence algorithms or algorithms based on 3D-DSA, TCD, and other parameters could be optimized and may be more suitable for intracranial arteries.

4.2 Limitations

In this study, we did not perform CTP and PWI examinations, focusing instead on a comparison between invasive pressure guide-wire measurement (CVPR) and non-invasive QFR measurement. Currently, cerebral vascular perfusion examination also plays an important role in clinical treatment decisions. Recognizing that evaluating in ICAS solely by stenosis rate and clinical symptoms is insufficient, the hemodynamics assessment in ICAS was very important, our team is dedicated to studying this condition in more depth. We have on-going research on perfusion-related data and its impact on CVPR, aiming to determine the cut off value of intracranial artery. We expect to have results available soon. Additionally, the small sample size of this study is one of its main limitations, primarily because the pressure guidewire measurement is an invasive procedure and is subject to many constraints. In the future studies, we will live this issue thorough consideration.

5 Conclusion

The calculated QFR derived from the angiographic view was related to CVPR by measuring the invasive pressure wire. The repeatability and reliability of QFR in intracranial atherosclerotic stenosis may reflect hemodynamic changes in the cerebral vasculature. Further studies are warranted to demonstrate that CVPR reliably and comprehensively reflects cerebral hemodynamics.

Data availability statement

The original contributions presented in the study are included in the article/supplementary material, further inquiries can be directed to the corresponding author/s.

Ethics statement

The studies involving humans were approved by Ethics Committee of Chinese PLA General hospital. The studies were conducted in accordance with the local legislation and institutional requirements. The participants provided their written informed consent to participate in this study.

Author contributions

XW: Data curation, Investigation, Methodology, Writing – original draft. YB: Data curation, Formal analysis, Resources, Writing – original draft. RZ: Data curation, Methodology, Writing – original draft. HZ: Investigation, Project administration, Writing – review & editing. JY: Conceptualization, Project administration, Resources, Writing – review & editing. RW: Formal analysis, Writing – review & editing. XL: Conceptualization, Methodology, Writing – review & editing. BL: Supervision, Validation, Writing – review & editing. XC: Methodology, Supervision, Writing – review & editing. WD: Formal analysis, Writing – review & editing. ZS: Software, Visualization, Writing – review & editing. JJ: Supervision, Validation, Writing – review & editing. ZD: Project administration, Resources, Supervision, Writing – review & editing. SY: Conceptualization, Resources, Supervision, Writing – review & editing. JW: Conceptualization, Funding acquisition, Methodology, Writing – review & editing.

Funding

The author(s) declare that no financial support was received for the research, authorship, and/or publication of this article.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Gutierrez, J, Turan, TN, Hoh, BL, and Chimowitz, MI. Intracranial atherosclerotic stenosis: risk factors, diagnosis, and treatment. Lancet Neurol. (2022) 21:355–68. doi: 10.1016/S1474-4422(21)00376-8

Crossref Full Text | Google Scholar

2. Gorelick, PB, Wong, KS, Bae, HJ, and Pandey, DK. Large artery intracranial occlusive disease: a large worldwide burden but a relatively neglected frontier. Stroke. (2008) 39:2396–9. doi: 10.1161/STROKEAHA.107.505776

Crossref Full Text | Google Scholar

3. Banerjee, C, and Chimowitz, MI. Stroke caused by atherosclerosis of the major intracranial arteries. Circ Res. (2017) 120:502–13. doi: 10.1161/CIRCRESAHA.116.308441

PubMed Abstract | Crossref Full Text | Google Scholar

4. Sacco, RL, Kargman, DE, Gu, Q, and Zamanillo, MC. Race-ethnicity and determinants of intracranial atherosclerotic cerebral infarction. The Northern Manhattan Stroke. Study Stroke. (1995) 26:14–20. doi: 10.1161/01.str.26.1.14

PubMed Abstract | Crossref Full Text | Google Scholar

5. Wong, LKS. Global burden of intracranial atherosclerosis. Int J Stroke. (2006) 1:158–9. doi: 10.1111/j.1747-4949.2006.00045.x

Crossref Full Text | Google Scholar

6. Kasner, SE, Chimowitz, MI, Lynn, MJ, Howlett-Smith, H, Stern, BJ, Hertzberg, VS, et al. Predictors of ischemic stroke in the territory of a symptomatic intracranial arterial stenosis. Circulation. (2006) 113:555–63. doi: 10.1161/CIRCULATIONAHA.105.578229

PubMed Abstract | Crossref Full Text | Google Scholar

7. Lv, B, Song, G, Jing, F, Li, M, Zhou, H, Li, W, et al. Mortality from cerebrovascular diseases in China: exploration of recent and future trends. Chin Med J. (2023) 7:2760. doi: 10.1097/CM9.0000000000002760

Crossref Full Text | Google Scholar

8. Derdeyn, P, Chimowitz, MI, Lynn, MJ, Fiorella, D, Turan, TN, Janis, LS, et al. Aggressive medical treatment with or without stenting in high-risk patients with intracranial artery stenosis (SAMMPRIS): the final results of a randomised trial. Lancet. (2014) 383:333–41. doi: 10.1016/S0140-6736(13)62038-3

PubMed Abstract | Crossref Full Text | Google Scholar

9. Yaghi, S, Havenon, AD, Honda, T, Hinman, JD, Raychev, R, Sharma, LK, et al. Impaired distal perfusion predicts length of hospital stay in patients with symptomatic middle cerebral artery stenosis. J Neuroimaging. (2021) 31:475–9. doi: 10.1111/jon.12839

PubMed Abstract | Crossref Full Text | Google Scholar

10. Cheng, XQ, Tian, JM, Zuo, CJ, Zhang, LJ, Zhou, CS, Zhao, YE, et al. Hemodynamic alterations in unilateral chronic middle cerebral artery stenosis patients and the effect of percutaneous transluminal angioplasty and stenting: a perfusion-computed tomography study. Acta Radiol. (2015) 56:754–60. doi: 10.1177/0284185114538793

PubMed Abstract | Crossref Full Text | Google Scholar

11. Katyal, A, Calic, Z, Killingsworth, M, and Bhaskar, SMM. Diagnostic and prognostic utility of computed tomography perfusion imaging in posterior circulation acute ischemic stroke: a systematic review and meta-analysis. Eur J Neurol. (2021) 28:2657–68. doi: 10.1111/ene.14934

PubMed Abstract | Crossref Full Text | Google Scholar

12. Miao, Z, Liebeskind, DS, Lo, W, Liu, LP, Pu, YH, Leng, XY, et al. Fractional flow assessment for the evaluation of intracranial atherosclerosis: a feasibility study. Interv Neurol. (2016) 5:65–75. doi: 10.1159/000444333

PubMed Abstract | Crossref Full Text | Google Scholar

13. Han, Y-F, Liu, W-H, Chen, X-L, Xiong, YY, Yin, Q, Xu, GL, et al. Severity assessment of intracranial large artery stenosis by pressure gradient measurements: a feasibility study. Catheter Cardiovasc Interv. (2016) 88:255–61. doi: 10.1002/ccd.26414

PubMed Abstract | Crossref Full Text | Google Scholar

14. de Bruyne, B, Pijls, NHJ, Kalesan, B, Barbato, E, Tonino, PA, Piroth, Z, et al. Fractional flow reserve-guided PCI versus medical therapy in stable coronary disease. N Engl J Med. (2012) 367:991–1001. doi: 10.1056/NEJMoa1205361

PubMed Abstract | Crossref Full Text | Google Scholar

15. Sen, S, Asrress, KN, Nijjer, S, Petraco, R, Malik, IS, Foale, RA, et al. Diagnostic classification of the instantaneous wave-free ratio is equivalent to fractional flow reserve and is not improved with adenosine administration. Results of CLARIFY (classification accuracy of pressure-only ratios against indices using flow study). J Am Coll Cardiol. (2013) 61:1409–20. doi: 10.1016/j.jacc.2013.01.034

PubMed Abstract | Crossref Full Text | Google Scholar

16. van de Hoef, TP, Meuwissen, M, Escaned, J, Sen, S, Petraco, R, van Lavieren, MA, et al. Head-to-head comparison of basal stenosis resistance index, instantaneous wave-free ratio, and fractional flow reserve: diagnostic accuracy for stenosis-specific myocardial ischaemia. EuroIntervention. (2015) 11:914–25. doi: 10.4244/EIJY14M08_17

PubMed Abstract | Crossref Full Text | Google Scholar

17. van de Hoef, TP, Lee, JM, Echavarria-Pinto, M, Koo, BK, Matsuo, H, Patel, MR, et al. Non-hyperaemic coronary pressure measurements to guide coronary interventions. Nat Rev Cardiol. (2020) 17:629–40. doi: 10.1038/s41569-020-0374-z

PubMed Abstract | Crossref Full Text | Google Scholar

18. Wienemann, H, Meyer, A, Mauri, V, Baar, T, Adam, M, Baldus, S, et al. Comparison of resting full-cycle ratio and fractional flow reserve in a German real-world cohort. Front Cardiovasc Med. (2021) 8:744181. doi: 10.3389/fcvm.2021.744181

PubMed Abstract | Crossref Full Text | Google Scholar

19. Kumar, G, Desai, R, Gore, A, Rahim, H, Maehara, A, Matsumura, M, et al. Real world validation of the nonhyperemic index of coronary artery stenosis severity-resting full-cycle ratio-RE-VALIDATE. Catheter Cardiovasc Interv. (2020) 96:E53–8. doi: 10.1002/ccd.28523

PubMed Abstract | Crossref Full Text | Google Scholar

20. Li, L, Yang, B, Dmytriw, AA, Wang, T, Luo, J, Li, Y, et al. Hemodynamic versus anatomic assessment of symptomatic atherosclerotic middle cerebral artery stenosis: the relationship between pressure wire translesional gradient and angiographic lesion geometry. Front Neurol. (2021) 12:671778. doi: 10.3389/fneur.2021.671778

PubMed Abstract | Crossref Full Text | Google Scholar

21. Tu, S, Westra, J, Yang, J, von Birgelen, C, Ferrara, A, Pellicano, M, et al. Diagnostic accuracy of fast computational approaches to derive fractional flow reserve from diagnostic coronary angiography: the international multicenter FAVOR pilot study. JACC Cardiovasc Interv. (2016) 9:2024–35. doi: 10.1016/j.jcin.2016.07.013

PubMed Abstract | Crossref Full Text | Google Scholar

22. Xu, B, Tu, S, Qiao, S, Qu, X, Chen, Y, Yang, J, et al. Diagnostic accuracy of angiography-based quantitative flow ratio measurements for online assessment of coronary stenosis. J Am Coll Cardiol. (2017) 70:3077–87. doi: 10.1016/j.jacc.2017.10.035

PubMed Abstract | Crossref Full Text | Google Scholar

23. Westra, J, Andersen, BK, Campo, G, Matsuo, H, Koltowski, L, Eftekhari, A, et al. Diagnostic performance of in-procedure angiography-derived quantitative flow reserve compared to pressure-derived fractional flow reserve: the FAVOR II Europe-Japan study. J Am Heart Assoc. (2018) 7:e009603. doi: 10.1161/JAHA.118.009603

PubMed Abstract | Crossref Full Text | Google Scholar

24. Tu, S, Ding, D, Chang, Y, Li, C, Wijns, W, and Xu, B. Diagnostic accuracy of quantitative flow ratio for assessment of coronary stenosis significance from a single angiographic view: a novel method based on bifurcation fractal law. Catheter Cardiovasc Interv. (2021) 97:1040–7. doi: 10.1002/ccd.29592

PubMed Abstract | Crossref Full Text | Google Scholar

25. Tu, S, Echavarria-Pinto, M, von Birgelen, C, Holm, NR, Pyxaras, SA, Kumsars, I, et al. Fractional flow reserve and coronary bifurcation anatomy: a novel quantitative model to assess and report the stenosis severity of bifurcation lesions. JACC Cardiovasc Interv. (2015) 8:564–74. doi: 10.1016/j.jcin.2014.12.232

PubMed Abstract | Crossref Full Text | Google Scholar

26. Kirkeeide, RL. Coronary obstructions, morphology and physiologic significance In: JHC Reiber and PW Serruys, editors. Quantitative coronary arteriography, vol. 117. Dordrecht: Springer Netherlands (1991). 229–44.

Google Scholar

27. Mehta, OH, Hay, M, Lim, RY, Ihdayhid, AR, Michail, M, Zhang, JM, et al. Comparison of diagnostic performance between quantitative flow ratio, non-hyperemic pressure indices and fractional flow reserve. Cardiovasc Diagn Ther. (2020) 10:442–52. doi: 10.21037/cdt-20-179

PubMed Abstract | Crossref Full Text | Google Scholar

28. Tegeler, CH, Crutchfield, K, Katsnelson, M, Kim, J, Tang, R, Passmore Griffin, L, et al. Transcranial Doppler velocities in a large, healthy population. J Neuroimaging. (2013) 23:466–72. doi: 10.1111/j.1552-6569.2012.00711.x

PubMed Abstract | Crossref Full Text | Google Scholar

29. Ahn, J-M, Nakayoshi, T, Hashikata, T, Kashiyama, K, Arashi, H, Kweon, J, et al. Impact of serial coronary stenoses on various coronary physiologic indices. Circ Cardiovasc Interv. (2022) 15:e012134. doi: 10.1161/CIRCINTERVENTIONS.122.012134

PubMed Abstract | Crossref Full Text | Google Scholar

30. van der Hoeven, EJRJ, Dankbaar, JW, Algra, A, Vos, JA, Niesten, JM, van Seeters, T, et al. Additional diagnostic value of computed tomography perfusion for detection of acute ischemic stroke in the posterior circulation. Stroke. (2015) 46:1113–5. doi: 10.1161/STROKEAHA.115.008718

PubMed Abstract | Crossref Full Text | Google Scholar

31. Xu, B, Tu, S, Song, L, Jin, Z, Yu, B, Fu, G, et al. Angiographic quantitative flow ratio-guided coronary intervention (FAVOR III China): a multicentre, randomised, sham-controlled trial. Lancet. (2021) 398:2149–59. doi: 10.1016/S0140-6736(21)02248-0

Crossref Full Text | Google Scholar

32. Leng, X, Wong, KS, and Liebeskind, DS. Evaluating intracranial atherosclerosis rather than intracranial stenosis. Stroke. (2014) 45:645–51. doi: 10.1161/STROKEAHA.113.002491

PubMed Abstract | Crossref Full Text | Google Scholar

33. Leng, X, Fang, H, Leung, TWH, Mao, C, Miao, Z, Liu, L, et al. Impact of collaterals on the efficacy and safety of endovascular treatment in acute ischaemic stroke: a systematic review and meta-analysis. J Neurol Neurosurg Psychiatry. (2016) 87:537–44. doi: 10.1136/jnnp-2015-310965

PubMed Abstract | Crossref Full Text | Google Scholar

34. Jalali Kondori, B, Azemati, F, and Dadseresht, S. Magnetic resonance angiographic study of anatomic variations of the circle of Willis in a population in Tehran. Arch Iran Med. (2017) 20:235–9.

PubMed Abstract | Google Scholar

35. Li, Q, Li, J, Lv, F, Li, K, Luo, T, and Xie, P. A multidetector CT angiography study of variations in the circle of Willis in a Chinese population. J Clin Neurosci. (2011) 18:379–83. doi: 10.1016/j.jocn.2010.07.137

PubMed Abstract | Crossref Full Text | Google Scholar

36. Muroya, T, Kawano, H, Hata, S, Shinboku, H, Sonoda, K, Kusumoto, S, et al. Relationship between resting full-cycle ratio and fractional flow reserve in assessments of coronary stenosis severity. Catheter Cardiovasc Interv. (2020) 96:E432–8. doi: 10.1002/ccd.28835

PubMed Abstract | Crossref Full Text | Google Scholar

37. Casanova-Sandoval, J, Fernández-Rodríguez, D, Otaegui, I, Gil Jiménez, T, Rodríguez-Esteban, M, Rivera, K, et al. Usefulness of the hybrid RFR-FFR approach: results of a prospective and multicenter analysis of diagnostic agreement between RFR and FFR-the RECOPA (REsting full-cycle ratio Comparation versus fractional flow reserve (a prospective validation)) study. J Interv Cardiol. (2021) 2021:5522707. doi: 10.1155/2021/5522707

PubMed Abstract | Crossref Full Text | Google Scholar

38. Chen, Z, Qin, H, Liu, J, Wu, B, Cheng, Z, Jiang, Y, et al. Characteristics of wall shear stress and pressure of intracranial atherosclerosis analyzed by a computational fluid dynamics model: a pilot study. Front Neurol. (2019) 10:1372. doi: 10.3389/fneur.2019.01372

PubMed Abstract | Crossref Full Text | Google Scholar

39. Liu, H, Lan, L, Leng, X, Ip, HL, Leung, TWH, Wang, D, et al. Impact of side branches on the computation of fractional flow in intracranial arterial stenosis using the computational fluid dynamics method. J Stroke Cerebrovasc Dis. (2018) 27:44–52. doi: 10.1016/j.jstrokecerebrovasdis.2017.02.032

PubMed Abstract | Crossref Full Text | Google Scholar

40. Lan, L, Leng, X, Ip, V, Soo, Y, Abrigo, J, Liu, H, et al. Sustaining cerebral perfusion in intracranial atherosclerotic stenosis: the roles of antegrade residual flow and leptomeningeal collateral flow. J Cereb Blood Flow Metab. (2020) 40:126–34. doi: 10.1177/0271678X18805209

PubMed Abstract | Crossref Full Text | Google Scholar

41. Feng, X, Chan, KL, Lan, L, Abrigo, J, Ip, VHL, Soo, YOY, et al. Translesional pressure gradient alters relationship between blood pressure and recurrent stroke in intracranial stenosis. Stroke. (2020) 51:1862–4. doi: 10.1161/STROKEAHA.119.028616

PubMed Abstract | Crossref Full Text | Google Scholar

42. Lan, L, Liu, H, Ip, V, Soo, Y, Abrigo, J, Fan, F, et al. Regional high wall shear stress associated with stenosis regression in symptomatic intracranial atherosclerotic disease. Stroke. (2020) 51:3064–73. doi: 10.1161/STROKEAHA.120.030615

PubMed Abstract | Crossref Full Text | Google Scholar

Keywords: intracranial atherosclerotic stenosis, hemodynamics, pressure wire, cerebrovascular pressure ratio, quantitative flow ratio, full-cycle ratio

Citation: Wang X, Bian Y, Zhang R, Zhu H, Yang J, Wang R, Liu X, Lv B, Cao X, Dai W, Sun Z, Jing J, Du Z, Yu S and Wang J (2024) Hemodynamic assessment of intracranial atherosclerotic stenosis: comparison between invasive non-hyperemic pressure ratio and angiography-derived quantitative flow ratio. Front. Neurol. 15:1466864. doi: 10.3389/fneur.2024.1466864

Received: 18 July 2024; Accepted: 01 November 2024;
Published: 13 November 2024.

Edited by:

Fuyou Liang, Shanghai Jiao Tong University, China

Reviewed by:

Shengzhang Wang, Fudan University, China
Tianqi Wang, University of Shanghai for Science and Technology, China

Copyright © 2024 Wang, Bian, Zhang, Zhu, Yang, Wang, Liu, Lv, Cao, Dai, Sun, Jing, Du, Yu and Wang. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Zhihua Du, ZHV6aGlodWExOTc4MTAyNEAxMjYuY29t; Shengyuan Yu, eXVzeTE5NjNAMTI2LmNvbQ==; Jun Wang, d2FuZ2p1bjMwMUAxMjYuY29t

These authors have contributed equally to this work

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.