Investigating associations between social determinants, self-efficacy measurement of sleep apnea and CPAP adherence: the SEMSA study

Thibaut GentinaThibaut Gentina1Elodie GentinaElodie Gentina2Bernard DouayBernard Douay1Jean-Arthur Micoulaud-Franchi,Jean-Arthur Micoulaud-Franchi3,4Jean-Louis Ppin,Jean-Louis Pépin5,6Sbastien Bailly,
Sébastien Bailly5,6*
  • 1Ramsey General Healthcare La Louviere Hospital, Lille, France
  • 2IESEG School of Management, CNRS, UMR 9221 – LEM – Lille Economie Management, Univ. Lille, Lille, France
  • 3SANPSY, UMR 6033, University of Bordeaux, Bordeaux, France
  • 4Sleep Medicine Service, University Hospital, Bordeaux, France
  • 5HP2 Laboratory, INSERM U1300, Univ. Grenoble Alpes, Grenoble, France
  • 6EFCR Laboratory, Grenoble Alpes University Hospital, Grenoble, France

Study objectives: The prospective Self-Efficacy Measure for Sleep Apnea study (SEMSAS) is investigating thresholds for health literacy, self-efficacy and precariousness at obstructive sleep apnea (OSA) diagnosis to predict CPAP adherence. This paper describes the study protocol and presents baseline data from the ongoing study.

Methods: Eligible individuals had confirmed OSA and were referred to a homecare provider for continuous positive airway pressure (CPAP) therapy initiation. Data on patient characteristics and comorbidities were collected, along with baseline evaluations of self-efficacy [15-item Self-Efficacy Measure for Sleep Apnea tool (SEMSA-15)], precariousness [Deprivation in Primary Care Questionnaire (DipCareQ)], and health literacy (Health Literacy Questionnaire). CPAP adherence over 12 months of follow-up will be determined using remote monitoring of CPAP device data. The primary objective is to define an optimal SEMSA-15 score threshold to predict CPAP adherence at 3- and 12-month follow-up.

Results: Enrollment of 302 participants (71% male, median age 55 years, median body mass index 31.6 kg/m2) is complete. Low self-efficacy (SEMSA-15 score ≤ 2.78) was found in 93/302 participants (31%), and 38 (12.6%) reported precariousness (DipCareQ score > 1); precariousness did not differ significantly between individuals with a SEMSA-15 score ≤ 2.78 versus >2.78. Health literacy was generally good, but was significantly lower in individuals with versus without precariousness, and with low versus high self-efficacy.

Conclusion: SEMSAS is the first study using multidimensional baseline assessment of self-efficacy, health literacy and precariousness, plus other characteristics, to determine future adherence to CPAP, including CPAP adherence trajectories. Collection of follow-up data is underway.

1. Introduction

Obstructive sleep apnea (OSA) is an important chronic condition that is characterized by repetitive complete (apnea) or partial (hypopnea) cessation of airflow due to collapse of the upper airway during sleep that induce symptoms or harms. The factors underlying these events are multifactorial and not fully understood, but are likely to include obesity, craniofacial features/changes, altered upper airway function, fluid shift towards the neck when in a supine position, and pharyngeal neuropathy (1).

OSA of at least mild severity has been estimated to affect nearly 1 billion adults aged 3–69 years worldwide (2). This is clinically relevant due to well-documented associations between OSA and several important neurocognitive, cardiovascular and metabolic comorbidities, including hypertension, cardiovascular disease, atrial fibrillation, diabetes, and even cancer (312). In addition, undiagnosed and untreated OSA have been associated with major depressive disorder, reduced quality of life, and increased healthcare utilization (1319).

The standard treatment for moderate-to-severe OSA is continuous positive airway pressure (CPAP), which splints the upper airway open during sleep (20). When used correctly and for an adequate duration each night, CPAP is highly effective in suppressing sleep-related respiratory events, and improving symptoms and cognitive function (20, 21). However, in real-life clinical practice settings, the effectiveness of CPAP for suppressing apneas and hypopneas, and ameliorating the negative clinical consequences of OSA, is limited by poor adherence rates and high rates of therapy termination (2224).

Numerous studies have investigated the clinical and physiological determinants of adherence to CPAP therapy. A high residual apnea-hypopnea index during treatment (>5–10 per hour) has been associated with poor adherence and high rates of therapy termination (25). In addition, device factors, such as the type of interface and its supply, have also been shown to influence longer-term adherence to PAP therapy (26). With respect to patient factors, higher income, educational level and number of household members have been associated with increased CPAP adherence in some studies, but currently available data are not consistent (2729). Low socioeconomic status (SES) is another predictor of poor adherence to CPAP, and individuals with higher SES are more likely to start therapy (27, 3032). Other factors that individually have been shown to increase the risk of non-adherence to CPAP therapy include low health literacy, forgoing healthcare, and precariousness (3335). OSA health literacy has been found to be lower in individuals with lower educational attainment and socioeconomic status (36). Socioeconomic disparities were acknowledged as contributing to sleep health disparities and CPAP adherence in a recent American Thoracic Society consensus document (37).

A good understanding of individual characteristics at the time of the diagnosis could help to predict CPAP adherence after treatment initiation and allow clinicians and homecare providers to better manage patient adherence trajectories by selecting and implementing the most appropriate strategies to increase adherence. However, the majority of currently published studies have only investigated a single, or small number of, determinants of CPAP adherence and no one factor has been consistently identified has having high predictive value. In addition, no study has yet investigated the contribution of health literacy, precariousness and self-efficacy measures, as well as clinical characteristics, to CPAP therapy adherence.

The Self-Efficacy Measure for Sleep Apnea (SEMSA) tool is a psychometrically acceptable self-report questionnaire for the measurement of health beliefs and behaviors in individuals with OSA being treated with CPAP (38). It was developed based on Bandura’s social cognitive theory (39) and originally included 26 items (38, 39). A shorter 15-item version (SEMSA-15) was developed to improve usability in clinical practice (40) while retaining similar psychometric properties to the original version. The SEMSA study (SEMSAS) has been designed to identify specific thresholds for health literacy, self-efficacy and precariousness assessed at the time of OSA diagnosis to predict CPAP adherence over the short (3 months) and long (12 months) term. The objective of this paper is to describe the study protocol and present baseline data relating to self-efficacy based on the SEMSA-15, precariousness and health literacy from the ongoing SEMSAS, which will soon complete follow-up.

2. Materials and methods

2.1. Study design

SEMSAS is a multicenter (n = 3), prospective observational cohort trial (NCT04894175) that started in May 2021 and finished recruiting in December 2022. All participants are from the North of France (Bétune, Denain and Lille), a region that includes areas that have differing levels of precariousness. The study protocol was approved by the French Comité de protection des personnes Nord Ouest III (ref 2020-68). As an observational study without changes in patient care or management, potential participants were provided with information about the study. Those who did not object to the use of their data for the study were included, in accordance with French law and European General Data Protection Regulation (GDPR).

2.2. Study participants

Eligible individuals were adults with a physician diagnosis of OSA who were referred for initiation of CPAP therapy managed by a homecare provider. Individuals without OSA or those with OSA that was not being treated with CPAP were not eligible.

2.3. Data acquisition and assessments

Clinicians collected demographic and clinical data at baseline (after enrollment/provision of informed consent), including age, height, weight, sex, comorbidities (hypertension, cardiovascular disease, diabetes, COPD, and asthma), OSA-related symptoms (presence or absence of any of the following: severe snoring, daytime sleepiness, daytime tiredness, morning headache, and nycturia), and method used for OSA diagnosis (single night polysomnography or polygraphy). The following data were collected at CPAP initiation: device, interface, pressure, and use of a humidifier (Figure 1). Data on CPAP adherence, residual AHI and leak were collected during follow-up, and data on quality of life and the ESS score were collected at the end of follow-up (Figure 1).

FIGURE 1
www.frontiersin.org

Figure 1. Study design and assessments. CPAP, continuous positive airway pressure; DipCare-Q, deprivation in primary care questionnaire; ESS, epworth sleepiness scale; HLQ, health literacy questionnaire; OSA; obstructive sleep apnea; PG, polygraphy; PSG, polysomnography; SEMSA-15, 15-item self-efficacy measure for sleep apnea; SF-12, Short Form-12.

Participants completed several baseline questionnaires that were provided by the homecare provider involved in setting up and initiating CPAP. These questionnaires gathered data relating to following parameters: personal characteristics (marital status, socioeconomic information, and health insurance); precariousness [the Deprivation in Primary Care Questionnaire (DipCareQ)] (41); health literacy [the Health Literacy Questionnaire (HLQ)] (42); chronotype (the degree to which individuals are active and alert at certain times of the day, primarily in the morning or evening); the shortened version of SEMSA (SEMSA-15 scale) (40); the 12-item Short Form health survey for quality of life (SF-12) (43); and the Epworth Sleepiness Scale (ESS) (44). The ESS and SF-12 will also be completed at the 12-month follow-up to allow assessment of the evolution of daytime sleepiness and quality of life during CPAP therapy.

2.3.1. DipCareQ

The DipCareQ questionnaire includes 16 questions about subjective social status, education, source of income, welfare status and subjective poverty that define deprivation in three distinct dimensions: material deprivation (eight items), social deprivation (five items), and health deprivation (three items) (41). Patients provide a yes or no answer to each question, with a score of 1 for yes and 0 for no. A score for each type of deprivation is determined, then a formula is used to calculate an overall score from 0 to 5, with higher scores indicating greater deprivation. For this study, DipCareQ score groups of 0–1 and 2–5 were used.

2.3.2. HLQ

The HLQ includes 44 items and covers nine distinct scales representing health literacy: (1) feeling understood and supported by healthcare providers; (2) having sufficient information to manage my health; (3) actively managing my health; (4) social support for health; (5) appraisal of health information; (6) ability to actively engage with healthcare providers; (7) navigating the healthcare system; (8) ability to find good health information; and (9) understand health information enough to know what to do (42). Responses for items in scales 1–5 are: strongly agree, disagree, agree and strongly agree. Responses for items in scales 6–9 are: cannot do, very difficult, quite difficult, easy, and very easy. Scale scores are determined by summing the item scores and then dividing by the number of items in the scale.

For scales 1–5 (four possible responses from strongly disagree to strongly agree), scores below 2.5 indicate that, on average, respondents tend to disagree with the statements within a scale. For scales 6–9 (five possible responses from cannot do/always difficult to always easy), scores below 3.5 indicate that, on average, respondents find the task within a scale difficult to do.

2.3.3. SEMSA-15

The SEMSA-15 includes five items each relating to perceived risks, outcome expectancies and self-efficacy, and has been shown to have the same good psychometric properties as the 26-item version (40). Items are groups into three subscales: perception of the consequences and risks of OSA (perceived risk); perception of the expected benefits of CPAP (outcome expectations); and feeling of self-efficacy in regular use of CPAP (self-efficacy). Each item is rated on a Likert scale from 1 to 4, with higher scores indicating greater risk perception, higher benefit expectancy with treatment, and greater perceived self-efficacy (38, 39). The final score is obtained by averaging scores for each item. With the SEMSA-15, the best classification performance for prediction of CPAP adherence was for the self-efficacy sub-score, with a cut-off value of 2.78 (sensitivity 57%, specificity 79%, positive predictive value 31%, and negative predictive value of 92%) (40).

2.4. Validity and reliability of measures

Exploratory and confirmatory factor analyses were conducted for each measurement scale. A Structural Equation Model (AMOS 26.0) tested the measurement models among all four using full information maximum likelihood estimation (FIML) with missing values estimation. The following criteria were used to assess configural invariance: χ2 and degrees of freedom (χ2/df < 5), Tucker–Lewis index (TLI >0.90), comparative fit index (CFI >0.90), incremental fit index (IFI >0.90), and root mean square error of approximation (RMSEA <0.10). The reliability coefficients for all constructs were acceptable (all Cronbach alpha’s > 0.70). Convergent validity (AVE >0.50) was based on Fornell and Larcker (45).

2.5. CPAP adherence and follow-up

CPAP adherence will be determined from remote monitoring of device data, and will be reported at 3 and 12 months after CPAP initiation. CPAP adherence will be reported as both a continuous variable and as a binary variable (threshold of 4 h/night).

Over the 12-month follow-up period reasons for loss of follow-up will be identified to differentiate between participants who stop using CPAP and are therefore non-adherent and those who stop participating in the study but remain adherent to CPAP or those who are deceased. In addition, the number and nature of physical interventions performed by the homecare provider technician during the follow-up period will be recorded.

2.6. Study objectives

The primary objective of SEMSAS is to define an optimal SEMSA-15 score threshold to predict adherence to CPAP at 3- and 12-month follow-up. The study also had a number of secondary objectives (Table 1). The objective of the current report is to present full details of the study protocol and describe baseline data relating to self-efficacy based on the SEMSA-15, precariousness and health literacy for enrolled participants.

TABLE 1
www.frontiersin.org

Table 1. Secondary study endpoints.

2.7. Sample size

The sample size calculation was based on achieving 90% power to identify an optimal threshold for the primary objective (i.e., the SEMSA-15 score threshold to predict 3- and 12-month CPAP adherence) with a minimum area under the receiver operator characteristic curve (ROC AUC) of 0.63. Assuming a CPAP non-adherence or therapy termination rate of 25% and a 20% loss to follow-up rate of 20%, it was calculated that 300 individuals would need to be included in the study.

2.8. Statistical analysis

2.8.1. Baseline data

In the current paper, qualitative variables are described using number and percentage, and qualitative variables as median and interquartile range (IQR). A Chi-squared test was used to compare qualitative variables and the Mann–Whitney test was used to compare quantitative variables. Effect sizes were computed using Cohen’ d coefficient for quantitative variable and phi coefficient for binary variables. Statistical analyses of baseline data were performed using SAS v9.4 (SAS Institute Inc., Cary, NC, United States). A value of p threshold of 0.05 was used to define statistical significance.

2.8.2. Methodology for follow-up analysis

The imputation strategy for missing values will be considered based on patterns of missingness and rate of missing values. For the primary objective, predictors of CPAP adherence (as a binary variable: <4 vs. ≥4 h/night) will be determined using a multivariable mixed logistic regression model, with a random effect on center determine possible variability between centers. Various parameters, including demographic and clinical covariables, will be considered as possible confounding factors based on clinical expertise and the results of univariable analysis. ROC AUC values for different models will be compared using the Delong method to identify which has the best performance and the Youden index will be used to define the optimal threshold for the SEMSA-15 questionnaire score. The dataset will be divided into two for training and validation (75% and 25% of the total sample, respectively). The model will be developed using the training dataset and then tested on the validation dataset. Performance of the final model, including sensitivity, specificity, and positive and negative predictive values, will be computed on the validation dataset.

Trajectories of CPAP adherence will be clustered by using specific approaches for time series, such as dynamic time warping, as previously described (46). Associations between patient characteristics and CPAP adherence trajectory clusters will be investigated by using comparison tests.

Multivariable linear generalized mixed effect models will be used to study the evolution of quality of life (SF-12 score) and daytime sleepiness (ESS score) over time. Confounding factors will be selected using univariable analyses and introduced into the model. Finally, unsupervised clustering will be performed to identify specific phenotypes at the time of the diagnosis and to investigate the impact of individual determinants such as health literacy, precariousness and SEMSA-15 score on patient clinical phenotype at baseline.

Finally, a structural equation model will be considered to identify direct and indirect relationships between measured variables and 12-month CPAP adherence. This approach will allow assessment of causal relationships between different measured factors and the outcome. For this approach, exploratory and confirmatory factorial analyses will be performed for each score to assess convergent and discriminant validity. Moderating effects, including precarity and individual determinants, will be considered by performing subgroup models.

Statistical analyses will be performed using a variety of different software, including SAS, R, and AMOS.

3. Results

3.1. Study population

A total of 302 individuals were included in the study. Participant characteristics were typical of an OSA population, being predominantly male, older age and high body mass index (Table 2). There were some differences between study centers with respect to OSA diagnosis, OSA severity, rate of hypertension, and SEMSA-15 score at baseline (Supplementary Table S1); these will be corrected for in the statistical analysis of follow-up data. Hypertension was the most common comorbidity, occurring in nearly half of the study population. Based on the apnea-hypopnea index (AHI), baseline OSA was severe, and the prevalence of symptoms was high. A majority of participants reported daytime sleepiness or tiredness, almost all had severe snoring, and more than half had morning headache. Most individuals (82.5%) were married or in a permanent relationship [median duration 26 years (range 12–42)]. Nearly half of all participants (44.5%) had children living at home. More than half (58.6%) reported a professional activity (of whom 40.2% were a worker or employee), 35.8% reported being a senior manager or business owner, while 24% reported an “intermediate” profession. Validity and reliability data for all measures being used in the study are shown in Supplementary Tables S2, S3.

TABLE 2
www.frontiersin.org

Table 2. Participant demographic and clinical characteristics at baseline, overall and in patient subgroups based on baseline 15-item self-efficacy measure for sleep apnea (SEMSA-15) score.

3.2. Self-efficacy at baseline

The median (IQR) SEMSA-15 score at baseline was 3 (2.7–3). Overall, 31% of the study population (n = 93/302) had low self-efficacy based on a SEMSA-15 score of was ≤2.78 in 93 patients. Overall demographic and clinical characteristics were generally comparable between individuals with a low SEMSA-15 score compared with those who had a high SEMSA-15 score. However, those with a SEMSA-15 score of ≤2.8 were significantly more likely to have heart failure and an ESS score of >10, but significantly less likely to report daytime sleepiness or daytime tiredness, compared with individuals who had a higher SEMSA-15 score (Table 2). Although statistically significant, the effect sizes for these differences were small. Most of the fit indices for each of these measurement models were within the acceptable range suggested by Collier (47). With respect to socio-economic characteristics, individuals with a high SEMSA-15 score usually had a graduate education and were in the high socio-professional category. Of the different SEMSA-15 subscales, scores were lowest for perceived risk and highest for outcome expectations (Table 3). The total score, and scores for all three subscales were significantly higher in the high versus low SEMSA-15 score group with a large effect size (Table 3).

TABLE 3
www.frontiersin.org

Table 3. Self-efficacy based on the SEMSA-15 score, overall and by subscale.

3.3. Precariousness at baseline

A total of 38 participants (12.6%) reported precariousness (based on a DipCareQ score > 1). Precariousness did not differ significantly between those with a SEMSA-15 score ≤ 2.78 versus >2.78, indicating that there was no association between self-efficacy and precariousness.

3.4. Health literacy and impact of precariousness and self-efficacy

Based on a threshold score of 2.5 for each item on the HLQ, the individuals with OSA enrolled in this study had a good level of health literacy (Table 4). Health literacy across most domains did differ significantly based on precariousness and self-efficacy, with median scores being significantly lower in patients with versus without precariousness (DipCareQ score > 1 vs. ≤1) and low versus high self-efficacy (SEMSA-15 score ≤ 2.78 vs. >2.78) (Table 4). Distributions around median values also varied between participant subgroups (Supplementary Figure S1).

TABLE 4
www.frontiersin.org

Table 4. Health literacy item scores for the overall population and in patient subgroups based on DipCareQ index score and SEMSA-15 score.

4. Discussion

The SEMSA study (SEMSAS) is the first to propose a multidimensional evaluation of determinants of CPAP adherence based on a combination of data including self-efficacy, precariousness, health literacy and individual characteristics/demographics. Data on these parameters will be used to predict CPAP adherence at 3 months and 1 year, and also to relate individual characteristics to CPAP adherence trajectories using remote monitoring data. It will be interesting to see associations between self-efficacy based on the SEMSA-15 score and other sociological evaluations. The inclusion and assessment of a broad range of potential factors that could influence adherence to CPAP should facilitate the identification of new predictors of CPAP adherence in conjunction with SEMSA-15, as well as confirm those already known to influence use of CPAP after therapy initiation.

Participants enrolled in SEMSAS have clinical characteristics that are indicative of a cohort with severe OSA and a clear indication for CPAP therapy. The study population showed a good level of health literacy, a low rate of precariousness, and more than two-thirds had good self-efficacy (based on a SEMSA-15 score > 2.78). Interestingly, there was no difference in precariousness between individuals with low or good self-efficacy even though other factors such as education level and profession did differ between patient subgroups based on SEMSA score (≤2.78 vs. >2.78). However, health literacy was significantly impacted by precariousness and self-efficacy, and was predictably lower in those with higher levels of precariousness and/or lower self-efficacy.

The rate of precariousness reported by study participants was 12.6%. To the best of our knowledge, SEMSAS is the first study to report precariousness in individuals starting CPAP. One previous analysis that included patients with OSA syndrome found that 43.7% reported deprivation based on the Evaluation de la précarité et des inégalités de santé dans les Centres d’examens de santé (EPICES) questionnaire score (36). Deprivation may differ from precariousness, limiting the ability to directly compare these findings. However, both studies were conducted in France and highlight the fact that precariousness and/or deprivation are likely to be important factors for a relevant proportion of individuals with OSA.

As described in the Methods section, the original SEMSA scale included 26 questions, but a shortened version was developed and validated (38) to improve clinical utility. It was this shorter version (SEMSA-15) that was used in the current study. Data on association between SEMSA-15 scores and adherence are only available from one previous study (as a secondary endpoint), where the self-efficacy subscale score was significantly correlated with mean CPAP usage at 1 month and a trend was found at 6 months (48). In addition, a number of previous prospective studies have reported an association between SEMSA-26 scores and CPAP adherence, although none had a follow-up period of longer than 3 months (28, 4955). In addition, the SEMSA-26 score has been found to be higher in individuals defined as CPAP adherers (3.5 ± 0.52) or CPAP attempters (3.1 ± 0.7) compared with CPAP non-adherers (2.8 ± 0.2) (48).

Poor adherence to CPAP therapy remains a challenge that limits the clinical benefits of treatment in real-world settings. Identifying which variables and data are able to predict CPAP adherence is crucial both for clinicians and homecare providers. This is likely to best be achieved by collecting information at the time of CPAP initiation to allow identification of individuals that might need additional support to achieve appropriate levels of CPAP adherence during long-term therapy. Appropriate and personalized measures can then be implemented during the early stages of treatment, allowing both adherence and the clinical benefits of CPAP therapy to be maximized.

Recruitment and collection of baseline data in SEMSAS are now complete. Adherence data at 3- and 12-month follow-up are being collated, which will allow this to be correlated with the extensive baseline data collected to provide a comprehensive picture of factors associated with CPAP adherence. In addition, data on CPAP adherence are being collected daily by remote monitoring utilizing the cloud connectivity features built in to CPAP devices. This will allow additional and informative analysis of CPAP adherence trajectories rather than just at two specific timepoints during follow-up.

In conclusion, SEMSAS aims to answer specific questions to help improve knowledge about patient determinants of CPAP adherence, especially self-efficacy, precariousness and health literacy. A multidimensional evaluation of data from these assessments combined with clinical/demographic data will allow more in-depth understanding of sociological concerns that are associated with poor CPAP adherence and could limit access to healthcare. The study findings should help to facilitate the identification of individuals who will be nonadherent to CPAP therapy, and determine specific clinical thresholds for several questionnaires that might help to differentiate between those who will be adherent or non-adherent.

Data availability statement

The raw data supporting the conclusions of this article will be made available by the authors under request.

Ethics statement

The studies involving human participants were reviewed and approved by French Comité de protection des personnes Nord Ouest III (ref 2020-68). The patients/participants provided their written informed consent to participate in this study.

Author contributions

TG: study conception, principal investigator, patient enrollment, interpretation of data, drafting of the manuscript, and data analysis and interpretation. EG: study conception and methodology, data management and data acquisition, and drafting of the manuscript. BD: study methodology, data acquisition and quality control, patient enrollment, and final check and approval of the manuscript. J-LP: study conception and methodology, and final check and approval of the manuscript. SB: study conception and methodology, data management, statistical analyses, and drafting of the manuscript. J-AM-F: final check and approval of the manuscript. All authors contributed to the article and approved the submitted version.

Funding

This study was funded by AUXILAIR, France. J-LP and SB are supported by the French National Research Agency in the framework of the “Investissements d’avenir” program (ANR-15-IDEX-02) and the “e-health and integrated care and trajectories medicine and MIAI artificial intelligence” Chairs of excellence from the Grenoble Alpes University Foundation. This work has been partially supported by MIAI @ university Grenoble Alpes (ANR-19-P3IA-0003).

Acknowledgments

Medical writing assistance was provided by Nicola Ryan, independent medical writer, funded by AUXILAIR, France.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary material

The Supplementary material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fneur.2023.1148700/full#supplementary-material

References

1. Lévy, P, Kohler, M, McNicholas, WT, Barbé, F, McEvoy, RD, Somers, VK, et al. Obstructive sleep apnoea syndrome. Nat Rev Dis Primers. (2015) 1:15015. doi: 10.1038/nrdp.2015.15

CrossRef Full Text | Google Scholar

2. Benjafield, AV, Ayas, NT, Eastwood, PR, Heinzer, R, Ip, MSM, Morrell, MJ, et al. Estimation of the global prevalence and burden of obstructive sleep apnoea: a literature-based analysis. Lancet Respir Med. (2019) 7:687–98. doi: 10.1016/s2213-2600(19)30198-5

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Gami, AS, Pressman, G, Caples, SM, Kanagala, R, Gard, JJ, Davison, DE, et al. Association of atrial fibrillation and obstructive sleep apnea. Circulation. (2004) 110:364–7. doi: 10.1161/01.Cir.0000136587.68725.8e

CrossRef Full Text | Google Scholar

4. Nieto, FJ, Peppard, PE, Young, T, Finn, L, Hla, KM, and Farré, R. Sleep-disordered breathing and cancer mortality: results from the Wisconsin sleep cohort study. Am J Respir Crit Care Med. (2012) 186:190–4. doi: 10.1164/rccm.201201-0130OC

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Lavie, P, Herer, P, and Hoffstein, V. Obstructive sleep apnoea syndrome as a risk factor for hypertension: population study. BMJ. (2000) 320:479–82. doi: 10.1136/bmj.320.7233.479

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Seicean, S, Kirchner, HL, Gottlieb, DJ, Punjabi, NM, Resnick, H, Sanders, M, et al. Sleep-disordered breathing and impaired glucose metabolism in normal-weight and overweight/obese individuals: the sleep heart health study. Diabetes Care. (2008) 31:1001–6. doi: 10.2337/dc07-2003

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Javaheri, S, Barbe, F, Campos-Rodriguez, F, Dempsey, JA, Khayat, R, Javaheri, S, et al. Sleep Apnea: types, mechanisms, and clinical cardiovascular consequences. J Am Coll Cardiol. (2017) 69:841–58. doi: 10.1016/j.jacc.2016.11.069

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Marin, JM, Carrizo, SJ, Vicente, E, and Agusti, AG. Long-term cardiovascular outcomes in men with obstructive sleep apnoea-hypopnoea with or without treatment with continuous positive airway pressure: an observational study. Lancet. (2005) 365:1046–53. doi: 10.1016/s0140-6736(05)71141-7

CrossRef Full Text | Google Scholar

9. Linz, D, Woehrle, H, Bitter, T, Fox, H, Cowie, MR, Böhm, M, et al. The importance of sleep-disordered breathing in cardiovascular disease. Clin Res Cardiol. (2015) 104:705–18. doi: 10.1007/s00392-015-0859-7

CrossRef Full Text | Google Scholar

10. Marshall, NS, Wong, KKH, Cullen, SRJ, Knuiman, MW, and Grunstein, RR. Sleep Apnea and 20-year follow-up for all-cause mortality, stroke, and cancer incidence and mortality in the Busselton health study cohort. J Clin Sleep Med. (2014) 10:355–62. doi: 10.5664/jcsm.3600

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Mitra, AK, Bhuiyan, AR, and Jones, EA. Association and risk factors for obstructive sleep Apnea and cardiovascular diseases: a systematic review. Diseases. (2021) 9:88. doi: 10.3390/diseases9040088

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Reutrakul, S, and Mokhlesi, B. Obstructive sleep Apnea and diabetes: a state of the art review. Chest. (2017) 152:1070–86. doi: 10.1016/j.chest.2017.05.009

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Baldwin, CM, Griffith, KA, Nieto, FJ, O'Connor, GT, Walsleben, JA, and Redline, S. The association of sleep-disordered breathing and sleep symptoms with quality of life in the sleep heart health study. Sleep. (2001) 24:96–105. doi: 10.1093/sleep/24.1.96

CrossRef Full Text | Google Scholar

14. Ding, Q, and Kryger, M. Greater health care utilization and cost associated with untreated sleep apnea. J Clin Sleep Med. (2020) 16:5–6. doi: 10.5664/jcsm.8152

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Edwards, C, Almeida, OP, and Ford, AH. Obstructive sleep apnea and depression: a systematic review and meta-analysis. Maturitas. (2020) 142:45–54. doi: 10.1016/j.maturitas.2020.06.002

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Lacasse, Y, Godbout, C, and Sériès, F. Health-related quality of life in obstructive sleep apnoea. Eur Respir J. (2002) 19:499–503. doi: 10.1183/09031936.02.00216902

CrossRef Full Text | Google Scholar

17. Wheaton, AG, Perry, GS, Chapman, DP, and Croft, JB. Sleep disordered breathing and depression among U.S. adults: National Health and nutrition examination survey, 2005-2008. Sleep. (2012) 35:461–7. doi: 10.5665/sleep.1724

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Sterling, KL, Cistulli, PA, Linde-Zwirble, W, Malik, A, Benjafield, AV, Malhotra, A, et al. Association between positive airway pressure therapy adherence and health care resource utilization in patients with obstructive sleep apnea and type 2 diabetes in the United States. J Clin Sleep Med. (2022) 19:563–71. doi: 10.5664/jcsm.10388

CrossRef Full Text | Google Scholar

19. Sterling, KL, Pépin, JL, Linde-Zwirble, W, Chen, J, Benjafield, AV, Cistulli, PA, et al. Impact of positive airway pressure therapy adherence on outcomes in patients with obstructive sleep Apnea and chronic obstructive pulmonary disease. Am J Respir Crit Care Med. (2022) 206:197–205. doi: 10.1164/rccm.202109-2035OC

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Patil, SP, Ayappa, IA, Caples, SM, Kimoff, RJ, Patel, SR, and Harrod, CG. Treatment of adult obstructive sleep apnea with positive airway pressure: an American Academy of sleep medicine clinical practice guideline. J Clin Sleep Med. (2019) 15:335–43. doi: 10.5664/jcsm.7640

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Condoleo, V, Bonfrate, L, Armentaro, G, Pelaia, C, Cassano, V, De Marco, M, et al. Effects of continuous positive airway pressure on comprehensive geriatric assessment and cognitive function in elderly patients with obstructive sleep apnea syndrome. Intern Emerg Med. (2023) 18:769–79. doi: 10.1007/s11739-023-03220-z

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Gervès-Pinquié, C, Bailly, S, Goupil, F, Pigeanne, T, Launois, S, Leclair-Visonneau, L, et al. Positive airway pressure adherence, mortality, and cardiovascular events in patients with sleep Apnea. Am J Respir Crit Care Med. (2022) 206:1393–404. doi: 10.1164/rccm.202202-0366OC

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Pépin, JL, Bailly, S, Rinder, P, Adler, D, Benjafield, AV, Lavergne, F, et al. Relationship between CPAP termination and all-cause mortality: a French Nationwide database analysis. Chest. (2022) 161:1657–65. doi: 10.1016/j.chest.2022.02.013

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Pépin, JL, Bailly, S, Rinder, P, Adler, D, Szeftel, D, Malhotra, A, et al. CPAP therapy termination rates by OSA phenotype: a French Nationwide database analysis. J Clin Med. (2021) 10:936. doi: 10.3390/jcm10050936

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Liu, D, Armitstead, J, Benjafield, A, Shao, S, Malhotra, A, Cistulli, PA, et al. Trajectories of emergent central sleep Apnea during CPAP therapy. Chest. (2017) 152:751–60. doi: 10.1016/j.chest.2017.06.010

PubMed Abstract | CrossRef Full Text | Google Scholar

26. Benjafield, AV, Oldstone, LM, Willes, LA, Kelly, C, Nunez, CM, Malhotra, A, et al. Positive airway pressure therapy adherence with mask resupply: a propensity-matched analysis. J Clin Med. (2021) 10:720. doi: 10.3390/jcm10040720

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Palm, A, Grote, L, Theorell-Haglöw, J, Ljunggren, M, Sundh, J, Midgren, B, et al. Socioeconomic factors and adherence to CPAP: the population-based course of disease in patients reported to the Swedish CPAP oxygen and ventilator registry study. Chest. (2021) 160:1481–91. doi: 10.1016/j.chest.2021.04.064

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Bakker, JP, O'Keeffe, KM, Neill, AM, and Campbell, AJ. Ethnic disparities in CPAP adherence in New Zealand: effects of socioeconomic status, health literacy and self-efficacy. Sleep. (2011) 34:1595–603. doi: 10.5665/sleep.1404

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Gulati, A, Ali, M, Davies, M, Quinnell, T, and Smith, I. A prospective observational study to evaluate the effect of social and personality factors on continuous positive airway pressure (CPAP) compliance in obstructive sleep apnoea syndrome. BMC Pulm Med. (2017) 17:56. doi: 10.1186/s12890-017-0393-7

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Wickwire, EM, Jobe, SL, Oldstone, LM, Scharf, SM, Johnson, AM, and Albrecht, JS. Lower socioeconomic status and co-morbid conditions are associated with reduced continuous positive airway pressure adherence among older adult medicare beneficiaries with obstructive sleep apnea. Sleep. (2020) 43:zsaa122. doi: 10.1093/sleep/zsaa122

PubMed Abstract | CrossRef Full Text | Google Scholar

31. Kendzerska, T, Gershon, AS, Tomlinson, G, and Leung, RS. The effect of patient Neighborhood income level on the purchase of continuous positive airway pressure treatment among patients with sleep Apnea. Ann Am Thorac Soc. (2016) 13:93–100. doi: 10.1513/AnnalsATS.201505-294OC

PubMed Abstract | CrossRef Full Text | Google Scholar

32. Simon-Tuval, T, Reuveni, H, Greenberg-Dotan, S, Oksenberg, A, Tal, A, and Tarasiuk, A. Low socioeconomic status is a risk factor for CPAP acceptance among adult OSAS patients requiring treatment. Sleep. (2009) 32:545–52. doi: 10.1093/sleep/32.4.545

PubMed Abstract | CrossRef Full Text | Google Scholar

33. Ellender, CM, Le Feuvre, S, Boyde, M, Duce, B, Winter, S, and Hukins, CA. Adequate health literacy is associated with adherence to continuous positive airway pressure in adults with obstructive SLEEP apnea. Sleep Adv. (2021) 2:zpab013. doi: 10.1093/sleepadvances/zpab013

PubMed Abstract | CrossRef Full Text | Google Scholar

34. Li, Y, Shikino, K, Terada, J, Katsumata, Y, Kinouchi, T, Koshikawa, K, et al. The relationship between CPAP and health literacy: a prospective observational study. J Gen Fam Med. (2022) 23:370–5. doi: 10.1002/jgf2.568

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Daabek, N, Tamisier, R, Foote, A, Revil, H, Joyeux-Jaure, M, Pépin, JL, et al. Impact of healthcare non-take-up on adherence to long-term positive airway pressure therapy. Front Public Health. (2021) 9:713313. doi: 10.3389/fpubh.2021.713313

PubMed Abstract | CrossRef Full Text | Google Scholar

36. Robbins, R, Hays, RD, Calderón, JL, Seixas, A, Newsome, V, Chung, A, et al. The development and psychometric evaluation of the survey of obstructive sleep Apnea functional health literacy. Sleep Med Res. (2021) 12:64–73. doi: 10.17241/smr.2021.00885

PubMed Abstract | CrossRef Full Text | Google Scholar

37. May, AM, Patel, SR, Yamauchi, M, Verma, TK, Weaver, TE, Chai-Coetzer, CL, et al. Moving toward Equitable Care for Sleep Apnea in the United States: positive airway pressure adherence thresholds: an official American Thoracic Society policy statement. Am J Respir Crit Care Med. (2023) 207:244–54. doi: 10.1164/rccm.202210-1846ST

PubMed Abstract | CrossRef Full Text | Google Scholar

38. Micoulaud-Franchi, JA, Coste, O, Bioulac, S, Guichard, K, Monteyrol, PJ, Ghorayeb, I, et al. A French update on the self-efficacy measure for sleep Apnea (SEMSA) to assess continuous positive airway pressure (CPAP) use. Sleep Breath. (2019) 23:217–26. doi: 10.1007/s11325-018-1686-7

PubMed Abstract | CrossRef Full Text | Google Scholar

39. Weaver, TE, Maislin, G, Dinges, DF, Younger, J, Cantor, C, McCloskey, S, et al. Self-efficacy in sleep apnea: instrument development and patient perceptions of obstructive sleep apnea risk, treatment benefit, and volition to use continuous positive airway pressure. Sleep. (2003) 26:727–32. doi: 10.1093/sleep/26.6.727

PubMed Abstract | CrossRef Full Text | Google Scholar

40. Dupuy, L, Bioulac, S, Coste, O, Guichard, K, Monteyrol, P-J, Ghorayeb, I, et al. Proposition of a shortened version of the self-efficacy measure for sleep Apnea (SEMSA-15): psychometric validation and cut-off score for CPAP adherence. Sleep Vigil. (2020) 4:17–21. doi: 10.1007/s41782-020-00083-8

CrossRef Full Text | Google Scholar

41. Vaucher, P, Bischoff, T, Diserens, EA, Herzig, L, Meystre-Agustoni, G, Panese, F, et al. Detecting and measuring deprivation in primary care: development, reliability and validity of a self-reported questionnaire: the DiPCare-Q. BMJ Open. (2012) 2:e000692. doi: 10.1136/bmjopen-2011-000692

PubMed Abstract | CrossRef Full Text | Google Scholar

42. Osborne, RH, Batterham, RW, Elsworth, GR, Hawkins, M, and Buchbinder, R. The grounded psychometric development and initial validation of the health literacy questionnaire (HLQ). BMC Public Health. (2013) 13:658. doi: 10.1186/1471-2458-13-658

PubMed Abstract | CrossRef Full Text | Google Scholar

43. Ware, J Jr, Kosinski, M, and Keller, SD. A 12-item short-form health survey: construction of scales and preliminary tests of reliability and validity. Med Care. (1996) 34:220–33. doi: 10.1097/00005650-199603000-00003

CrossRef Full Text | Google Scholar

44. Johns, MW. A new method for measuring daytime sleepiness: the Epworth sleepiness scale. Sleep. (1991) 14:540–5. doi: 10.1093/sleep/14.6.540

CrossRef Full Text | Google Scholar

45. Fornell, C, and Larcker, DF. Evaluating structural equation models with unobservable variables and measurement error. J Mark Res. (1981) 18:39–50. doi: 10.1177/002224378101800104

CrossRef Full Text | Google Scholar

46. Bottaz-Bosson, G, Hamon, A, Pépin, JL, Bailly, S, and Samson, A. Continuous positive airway pressure adherence trajectories in sleep apnea: clustering with summed discrete Fréchet and dynamic time warping dissimilarities. Stat Med. (2021) 40:5373–96. doi: 10.1002/sim.9130

PubMed Abstract | CrossRef Full Text | Google Scholar

47. Collier, JE. Applied structural equation modelling using AMOS. New York: Routledge (2020).

Google Scholar

48. Gauld, C, Rhanmi, H, Philip, P, and Micoulaud-Franchi, JA. Validation of the French cues to CPAP use questionnaire in patients with OSAS: a step forward for evaluating cues to CPAP use in order to predict treatment adherence. J Psychosom Res. (2022) 158:110943. doi: 10.1016/j.jpsychores.2022.110943

PubMed Abstract | CrossRef Full Text | Google Scholar

49. Olsen, S, Smith, S, Oei, T, and Douglas, J. Health belief model predicts adherence to CPAP before experience with CPAP. Eur Respir J. (2008) 32:710–7. doi: 10.1183/09031936.00127507

PubMed Abstract | CrossRef Full Text | Google Scholar

50. Sawyer, AM, Canamucio, A, Moriarty, H, Weaver, TE, Richards, KC, and Kuna, ST. Do cognitive perceptions influence CPAP use? Patient Educ Couns. (2011) 85:85–91. doi: 10.1016/j.pec.2010.10.014

PubMed Abstract | CrossRef Full Text | Google Scholar

51. Sawyer, AM, King, TS, Hanlon, A, Richards, KC, Sweer, L, Rizzo, A, et al. Risk assessment for CPAP nonadherence in adults with newly diagnosed obstructive sleep apnea: preliminary testing of the index for nonadherence to PAP (I-NAP). Sleep Breath. (2014) 18:875–83. doi: 10.1007/s11325-014-0959-z

PubMed Abstract | CrossRef Full Text | Google Scholar

52. Wallace, DM, Shafazand, S, Aloia, MS, and Wohlgemuth, WK. The association of age, insomnia, and self-efficacy with continuous positive airway pressure adherence in black, white, and Hispanic U.S. Veterans. J Clin Sleep Med. (2013) 09:885–95. doi: 10.5664/jcsm.2988

PubMed Abstract | CrossRef Full Text | Google Scholar

53. Lai, AY, Fong, DY, Lam, JC, Weaver, TE, and Ip, MS. Linguistic and psychometric validation of the Chinese version of the self-efficacy measures for sleep apnea questionnaire. Sleep Med. (2013) 14:1192–8. doi: 10.1016/j.sleep.2013.04.023

PubMed Abstract | CrossRef Full Text | Google Scholar

54. Ye, L, Pack, AI, Maislin, G, Dinges, D, Hurley, S, McCloskey, S, et al. Predictors of continuous positive airway pressure use during the first week of treatment. J Sleep Res. (2012) 21:419–26. doi: 10.1111/j.1365-2869.2011.00969.x

PubMed Abstract | CrossRef Full Text | Google Scholar

55. Wallace, DM, Vargas, SS, Schwartz, SJ, Aloia, MS, and Shafazand, S. Determinants of continuous positive airway pressure adherence in a sleep clinic cohort of South Florida Hispanic veterans. Sleep Breath. (2013) 17:351–63. doi: 10.1007/s11325-012-0702-6

CrossRef Full Text | Google Scholar

Keywords: obstructive sleep apnea, continuous positive airway pressure, adherence, health behavior, health literacy

Citation: Gentina T, Gentina E, Douay B, Micoulaud-Franchi J-A, Pépin J-L and Bailly S (2023) Investigating associations between social determinants, self-efficacy measurement of sleep apnea and CPAP adherence: the SEMSA study. Front. Neurol. 14:1148700. doi: 10.3389/fneur.2023.1148700

Received: 20 January 2023; Accepted: 29 June 2023;
Published: 17 July 2023.

Edited by:

Henri Korkalainen, University of Eastern Finland, Finland

Reviewed by:

Ashley H. Sanderlin, North Carolina Agricultural and Technical State University, United States
Corrado Pelaia, Magna Græcia University, Italy

Copyright © 2023 Gentina, Gentina, Douay, Micoulaud-Franchi, Pépin and Bailly. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Sébastien Bailly, sbailly@chu-grenoble.fr

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.