Skip to main content

REVIEW article

Front. Neurol., 02 June 2022
Sec. Sleep Disorders
This article is part of the Research Topic Insights in Sleep Disorders: 2021 View all 8 articles

Changes in Periodic Limb Movements of Sleep After the Use of Continuous Positive Airway Pressure Therapy: A Meta-Analysis

\nTzu-Chao Lin&#x;Tzu-Chao Lin1Bing-Yan Zeng&#x;Bing-Yan Zeng2Meng-Ni Wu,,Meng-Ni Wu1,3,4Tien-Yu Chen,Tien-Yu Chen5,6Yen-Wen ChenYen-Wen Chen7Pin-Yang Yeh,Pin-Yang Yeh8,9Ping-Tao Tseng,,
Ping-Tao Tseng7,8,10*Chung-Yao Hsu,,
Chung-Yao Hsu1,3,4*
  • 1Department of Neurology, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
  • 2Department of Internal Medicine, E-DA Dachang Hospital, Kaohsiung, Taiwan
  • 3Department of Neurology and Sleep Disorders Center, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
  • 4Department of Neurology, Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
  • 5Department of Psychiatry, Tri-Service General Hospital, School of Medicine, National Defense Medical Center, Taipei, Taiwan
  • 6Institute of Brain Science, National Yang Ming Chiao Tung University, Taipei, Taiwan
  • 7Prospect Clinic for Otorhinolaryngology & Neurology, Kaohsiung, Taiwan
  • 8Department of Psychology, College of Medical and Health Science, Asia University, Taichung, Taiwan
  • 9Clinical Psychology Center, Asia University Hospital, Taichung, Taiwan
  • 10Institute of Biomedical Sciences, National Sun Yat-sen University, Kaohsiung, Taiwan

Background: Both obstructive sleep apnea (OSA) and periodic limb movements of sleep (PLMS) are common in the sleep laboratory. The severity of OSA can be improved by using continuous positive airway pressure (CPAP). However, increasing evidence has shown an elevated periodic limb movement index (PLMI) in patients with OSA who use CPAP, although the pathophysiology is still unknown. This meta-analysis aimed to investigate changes in PLMS after using CPAP and the potential pathophysiology of these changes.

Methods: Clinical trials in adult humans investigating the comorbidity between PLMS and CPAP were identified and analyzed using random-effects model meta-analysis.

Results: This meta-analysis included 14 studies comprising 2,938 patients with OSA. The PLMI was significantly increased after using CPAP with a difference in means of 1.894 (95% confidence interval = 0.651–3.138, p = 0.003). Subgroup analysis showed that CPAP was only significantly associated with an increase in PLMI in the patients without PLMS at baseline (p = 0.045) and in those with a baseline body-mass index <30 kg/m2 (p = 0.045). The use of CPAP, apnea-hypopnea index, and arousal index were positively correlated with changes in PLMI.

Conclusion: These characteristics may serve as qualitative predictive indicators of changes in PLMI after CPAP usage. Further analysis of the quantitative relationships between PLMI and the predictive indicators may be warranted.

Trial Registration: PROSPERO (registration number: CRD42021252635).

Introduction

Obstructive sleep apnea (OSA) and periodic limb movements during sleep (PLMS) are commonly encountered in the sleep laboratory. The prevalence of OSA in the general population is about 2%−7% in adults (1), while that of PLMS is about 5%−11% (2). A high proportion of subjects with OSA have been reported to have concurrent PLMS, with a comorbidity rate of about 24%−28% (3). Continuous positive airway pressure (CPAP) is a standard treatment for OSA (4), and it has been shown to reduce the apnea–hypopnea index (AHI) and improve sleep quality (5).

Several studies have reported changes in the severity of PLMS during CPAP treatment in OSA patients (6). This phenomenon has also been reported in later clinical trials, however the results of these clinical trials have been inconsistent. Some trials have shown the potential beneficial effect of CPAP in OSA patients to reduce the severity of PLMS (79). For example, Kerkhofs and colleague found that CPAP could reduce the leg movement index with regards to time in bed [LMI (TIB)] from 391 per hour to 22.5 per hour in patients with OSA (8). In contrast, several recent trials have reported different findings (10). Wu et al. reported increased periodic limb movement index (PLMI) in OSA patients after using CPAP (10). However, another trial suggested that there might not be an association between the usage of CPAP in OSA patients and changes in PLMI (11).

Patients with a higher frequency of PLMS have been associated with more severe cardiovascular disease (12). In addition, the use of CPAP has been associated with a higher PLMI in certain populations, for example, the elderly, patients with chronic kidney disease, and those with higher baseline AHI (10, 13). This may imply the potential cardiovascular effect of residual PLMS after using CPAP, since CPAP per se aims to decrease the cardiovascular impact. Although the Sleep Apnea Cardiovascular Endpoints (SAVE) study reported that CPAP did not prevent cardiovascular events in patients with moderate-to-severe OSA (14), other study reported that CPAP reduced the risk of cardiovascular disease in patients with OSA and heart failure (15). Consequently, it is unclear which population may benefit from the cardiovascular protective effects of CPAP. Data on quantized, efficient and reliable indices for predicting an increase in the frequency of PLMS in OSA patients using CPAP are currently lacking. However, this is an important issue, as CPAP treatment may not provide as much cardiovascular protection in some patients as in others, and it could potentially lead to harm.

Patients with a higher PLMS frequency have also been reported to have worse sleep quality (16). Consequently, patients who experience an increase in the frequency of PLMS while using CPAP may also have a deterioration in the quality of sleep, which may in turn lower CPAP compliance. Identifying these patients before initiating CPAP could allow clinical physicians to inform the patient of the potential deterioration in sleep quality, thereby maintaining rapport and increasing the likelihood of better compliance with future medical plans. Therefore, it is vital to elucidate whether the application of CPAP affects the PLMI in patients with OSA.

The aim of this meta-analysis was to clarify the changes in PLMI associated with the use of CPAP in OSA patients, and to identify potential characteristics of OSA patients to predict these changes in PLMI.

Methods and Materials

In this study, we followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guidelines (17) (Supplementary Table 1 and Figure 1) and AMSTAR2 (a measurement tool to assess systematic reviews) guidelines (18). The current study is registered in PROSPERO (registration number: CRD42021252635). In addition, the study protocol of the current meta-analysis (Appendix: study protocol) was approved by the Institutional Review Board of Tri-Service General Hospital (TSGHIRB: B-109-29).

FIGURE 1
www.frontiersin.org

Figure 1. Flowchart of the current meta-analysis.

Database Searches and Identification of Eligible Papers

Two well-trained and independent authors (T-CL and B-YZ) performed electronic searches of PubMed, Embase, ScienceDirect, ClinicalKey, Cochrane Library, ProQuest, Web of Science, and ClinicalTrials.gov using the keywords (CPAP OR continuous positive airway pressure) AND (PLM OR periodic limb movement during sleep OR PLMD OR periodic limb movement disorder) up to May 8th, 2021 (detailed keyword and search results are shown in Supplementary Table 2). In the initial stage, both authors screened the titles and abstracts for eligibility through consensus. If a consensus could not be reached, a third author (P-TT) was consulted. Furthermore, in order to increase the number of included studies, we hand searched the reference lists of review articles and clinical guidelines (9).

Inclusion and Exclusion Criteria

The PICO applied in this meta-analysis was: (1) Patient or Problem: patients with sleep apnea, either central or obstructive; (2) Intervention: CPAP; (3) Comparator: before and after CPAP treatment; and (4) Outcome: changes in PLMI.

Therefore, the inclusion criteria when screening the eligible studies identified from the search were: (1) formal published articles investigating changes in PLMI before and after CPAP treatment, either in forms of a pre-post comparison design or placebo-controlled trial; and (2) articles that were clinical trials in adult humans. To expand the potential eligibility, we did not set any limitations. The exclusion criteria were: (1) animal studies; and (2) articles not related to changes in PLMI before and after CPAP treatment.

Methodological Quality Appraisal

To investigate the methodological quality of the recruited studies, we used the Jadad scale, which ranges from zero (poor quality) to five (high quality) (19).

Primary Outcome

The primary outcome was the change in PLMI, which was defined as the rate of PLM during sleep (PLM/hour) recorded by polysomnography based on either the American Association of Sleep Medicine (AASM) guidelines (20) or Coleman's criteria (21).

Secondary Outcome

The secondary outcome was defined as the change in PLM with arousal index (PLMAI) recorded by polysomnography based on either the AASM guidelines (20) or Coleman's criteria (21).

Data Extraction and Management

Based on the predetermined clinical variables of interest, the two authors (T-CL and B-YZ) extracted data from the recruited studies, including mean age (years), gender, body mass index (BMI), sleep parameters recorded by polysomnography, including total sleep time (TST) (min), sleep efficiency (%), percentage of deep sleep phase (i.e. non-rapid eye movement (NREM) stage, N3 sleep phase) (%), percentage of rapid eye movement (REM) sleep phase (%), REM sleep onset latency (min), sleep onset latency (min), AHI, arousal index (AI), oxygen desaturation index (ODI), mean O2 saturation, Epworth Sleepiness Scale (ESS), and Jadad scores.

In situations where data were unavailable in a study, we tried to contact the corresponding authors to request the original data on at least two different occasions.

Meta-Analysis

Based on the presumed heterogeneity of the populations among the recruited studies, the current meta-analysis was conducted using random-effects meta-analysis models. The meta-analysis procedure was performed using Comprehensive Meta-Analysis software, version 3 (Biostat, Englewood, NJ). We chose differences in means and 95% confidence intervals (95% CIs) as the main effect sizes (ESs) of the primary outcome (change in PLMI) and secondary outcome (change in PLMAI). Two-tailed p values < 0.05 were considered to be statistically significant.

Heterogeneity, Publication Bias, and Sensitivity Test

To detect potential heterogeneity, we used the Q statistic and corresponding p values (22). In addition, we visually inspected funnel plots when there were fewer than 10 datasets (23), and used Egger's regression test when there were 10 or more datasets (24). We used the Duval and Tweedie trim and fill test when there was evidence of publication bias (25).

Sensitivity testing was done using the one study removal method, in which one study was excluded from the analysis at a time, to observe whether the significant or insignificant results of the meta-analysis were biased by an outlier (26).

Meta-Regression and Subgroup Meta-Analysis

We used meta-regression and subgroup meta-analyses to identify potential sources of heterogeneity and confounding factors. Specifically, in situations of at least 10 datasets, we performed meta-regression using the unrestricted maximum likelihood method. The variables of interest for meta-regression were mean age, proportion of females, BMI, TST, sleep efficiency, percentage of deep sleep phase, percentage of REM sleep phase, REM sleep onset latency, sleep onset latency, AHI, AI, ODI, mean O2 saturation, ESS, and Jadad scores. In addition, we performed subgroup meta-analysis when there were at least three datasets (27). We also performed subgroup meta-analysis among different groups with/without baseline PLMS, and BMI higher/lower than 30 kg/m2.

Results

Study Selection

The protocol of study selection for the current meta-analysis is depicted in Figure 1. In brief, 29 full-text articles were considered to be eligible for screening. Among them, 15 were excluded because they did not fulfill the inclusion criteria (reasons summarized in Figure 1 and Supplementary Table 3), and the remaining 14 articles were enrolled in this meta-analysis (3, 7, 8, 10, 13, 2836) (Table 1).

TABLE 1
www.frontiersin.org

Table 1. Characteristics of the included studies.

Among the 14 articles, 13 were pre-post comparisons and only one was a randomized controlled trial. All of these articles provided data on changes in PLMI before and after CPAP treatment (3, 7, 8, 10, 13, 2836) (participants = 2,938, mean age = 49.3 years, mean female proportion = 16.9%). Furthermore, five provided changes in PLMI in patients without baseline PLMS or baseline PLMI <5 (7, 13, 32, 33, 36) (participants = 1,872, mean age = 47.2 years, mean female proportion = 10.4%), and seven provided changes in PLMI in those with baseline PLMS or baseline PLMI ≥5 (3, 7, 8, 13, 28, 29, 36) (participants = 367, mean age = 53.1 years, mean female proportion = 21.7%). In addition, five articles provided changes in PLMAI before and after CPAP treatment (7, 10, 28, 29, 31) (participants = 149, mean age = 57.2 years, mean female proportion = 24.3%). The patients in the recruited studies had a diagnosis of sleep-disordered breathing plus PLMS (28), sleep-disordered breathing plus chronic kidney disease (10), sleep-disordered breathing only (7, 31, 34, 35), sleep apnea-hypopnea syndrome with high leg activity (8), or obstructive sleep apnea syndrome only (3, 13, 29, 30, 36).

Methodological Quality of the Included Studies

Across the 14 studies, the average Jadad score was 0.8 with a standard deviation (SD) of 0.4 (Supplementary Table 4).

Primary Outcome: Changes in PLMI Before and After CPAP Treatment

The 14 articles provided 22 datasets of changes in PLMI before and after CPAP treatment (3, 7, 8, 10, 13, 2836). The main results of the meta-analysis revealed that PLMI was significantly increased after CPAP treatment with a difference in means of 1.894 (95% CI = 0.651–3.138, p = 0.003; Figure 2A) with significant heterogeneity (Q value = 187.278, df = 21, p < 0.001; I2 = 88.787%) but not publication bias via Egger's regression (t-value = 1.390, df = 20, p = 0.180).

FIGURE 2
www.frontiersin.org

Figure 2. (A) Forest plot of changes in PLMI before and after CPAP treatment. (B) Forest plot of changes in PLMI before and after CPAP treatment: subgroup baseline PLMS. (C) Forest plot of changes in PLMI before and after CPAP treatment: subgroup baseline BMI. (D) Forest plot of changes in PLMAI before and after CPAP treatment. In (A–D), effect sizes >0 indicated that CPAP treatment was associated with increased PLMI or PLMAI. AHI, apnea-hypopnea index; BMI, body mass index; CI, confidence interval; CPAP, continuous positive airway pressure; PLMS, periodic limb movements of sleep; PLMAI, periodic limb movement with arousal index; PLMI, periodic limb movement index; PSG, polysomnography.

Sensitivity Test

The sensitivity test via one study removed revealed that the main results of the meta-analysis became insignificant after removing the dataset by Wu et al. (32) (difference in means = 1.193, 95% CI = −0.009 to 2.396, p = 0.052).

Meta-Regression

The meta-regression showed that there were only significant positive associations between changes in PLMI and female proportion (k = 22, slope = 0.155, p < 0.001), AHI at baseline (k = 20, slope = 0.157, p = 0.048), and AI at baseline (k = 10, slope = 1.744, p = 0.002), but not mean age (p = 0.556) or BMI (p = 0.194) (Supplementary Figures 1A–E).

Subgroup Meta-Analysis: The Presence of Baseline PLMS

We then performed subgroup meta-analysis according to the baseline PLMI status among the recruited patients. According to the International Classification of Sleep Disorders (ICSD-3), a PLMI of 5 or more is regarded as abnormal (14). The four articles that provided changes in PLMI in patients without baseline PLMS or baseline PLMI <5 included a total of six datasets (7, 13, 32, 36). The subgroup meta-analysis results revealed a significant increase in PLMI after CPAP treatment (k = 6, difference in means = 1.241, 95% CI = 0.028–2.454, p = 0.045; Figure 2B). In addition, seven studies with 10 datasets (3, 7, 8, 13, 28, 29, 36) provided changes in PLMI in patients with baseline PLMS ≥5. The subgroup meta-analysis results revealed that there was no significant change in PLMI after CPAP treatment (k = 10, difference in means = −2.007, 95% CI = −10.011 to 5.997, p = 0.623; Figure 2B).

Subgroup Meta-Analysis: Differences in Baseline BMI

We performed further subgroup meta-analysis based on a cut-off baseline BMI of 30 kg/m2. Five studies with seven datasets (8, 13, 32, 34, 36) provided data on patients with a baseline BMI <30 kg/m2. The subgroup meta-analysis results revealed a significant increase in PLMI after CPAP treatment (k = 11, difference in means = 1.568, 95% CI = 0.038–3.098, p = 0.045; Figure 2C). In addition, six studies with eight datasets (3, 7, 30, 31, 33, 35) provided data on patients with a baseline BMI ≥30 kg/m2. The subgroup meta-analysis results revealed that there was no significant change in PLMI after CPAP treatment (k = 8, difference in means = 1.424, 95% CI = −1.742 to 4.589, p = 0.378; Figure 2C).

Secondary Outcome: Changes in PLMAI Before and After CPAP Treatment

Six of the articles provided six datasets of changes in PLMAI before and after CPAP treatment (7, 10, 28, 29, 31, 33). The main results of the meta-analysis revealed that there was no significant change in PLMAI before or after CPAP treatment (k = 6, difference in means = 0.434, 95% CI = −2.191 to 3.060, p = 0.746; Figure 2D) with significant heterogeneity (Q value = 37.238, df = 5, p < 0.001; I2 = 86.573%) and significant publication bias via inspection of funnel plots (Supplementary Figure 2). The adjusted estimated ESs by Duval and Tweedie's trim and fill test remained insignificant (adjusted difference in means = −0.045, 95% CI = −2.629 to 2.539).

Sensitivity Test

The sensitivity test via one study removed revealed that the insignificant results of the meta-analysis did not change by removing of any one of the studies. Therefore, the insignificant results were not due to an outlier.

Discussion

To the best of our knowledge, this is the first meta-analysis to address the changes in PLMI associated with CPAP treatment. The major finding of the current study is the significant increase in PLMI after using CPAP, which was independent of the presence of PLMS at baseline and a baseline BMI <30 kg/m2. Specifically, the PLMI was significantly increased after CPAP treatment with strong positive associations with baseline AHI and AI (slope = 0.157, p = 0.048 and slope = 1.744, p = 0.002, respectively), while there were no significant changes in PLMAI. Furthermore, only the subgroups with a baseline minimal PLMI (<5 or without baseline PLMS) and BMI <30 kg/m2 had a significant increase in PLMI associated with CPAP treatment.

The increase in PLMI after CPAP treatment found in this meta-analysis is consistent with previous studies (7, 13). However, clear pathophysiological explanations for the effect of CPAP on the increase in PLMI are still lacking. Baran et al. (3) hypothesized that CPAP may increase PLMI either through OSA-related sleep fragmentation or CPAP-triggered sleep fragmentation and bodily discomfort. However, further studies are needed to elucidate this issue.

Our subgroup meta-analysis showed that the OSA patients without PLMS (or PLMI <5) at baseline had an increase in PLMI after CPAP treatment, but those with PLMS (or PLMI ≥5) at baseline showed no obvious change in PLMI. Pathophysiological explanations for this result are also lacking. In a recent study focusing on OSA patients who received CPAP treatment, emerging PLMS (increase in PLMS by 5/h with the disappearance of respiratory events after CPAP treatment) accounted for about 30% of the patients, which inevitably increased PLMI scores after CPAP treatment (16). This may explain the elevation in PLMI after CPAP treatment in the subgroup with PLMI <5. In the same study, the authors suggested that serum ferritin could predict an increase in PLMI rather than the initial PLMI score. Therefore, a low ferritin level, rather than initial low PLMI, may be a predictor of a higher frequency of PLMS after CPAP treatment. Accordingly, despite the subgroup results, ferritin level may be more pathophysiologically useful than baseline PLMI in predicting changes in PLMI after CPAP treatment. However, this hypothesis requires further verification as it was based on only a single study, and because ferritin is not more pathologically plausible than baseline PLMI in predicting an increase in PLMI.

Our results also showed that the patients with higher baseline AHI had a greater increase in PLMI after using CPAP. Explanations for this finding are lacking. Some studies have reported that arousals showed the same tendency as PLMI in patients using CPAP (3, 29). Although some previous studies have reported a tendency of PLMI, arousals and AHI to increase in patients using CPAP, further studies are needed to investigate these effects before reasonable pathophysiological explanations can be drawn.

In our main results, BMI was not correlated with CPAP treatment. However, in subgroup analysis, those with a BMI <30 kg/m2 had an increase in PLMI after using CPAP. PLMS is known to be most active during the transition from wakefulness to sleep and most NREM sleep (light NREM sleep), and then to be attenuated during very deep NREM sleep and even more during REM sleep (16). According to a case control study, after 3 months of CPAP treatment, people with normal BMI (NG, range from 18 to 25 kg/m2) seemed to have an increase in NREM sleep (baseline 69.6% of TID increasing to 70.9%), whereas the obese group (OG, range from 30 to 40 kg/m2) and severely obese group (SOG, >40 kg/m2) had a decrease (OG baseline 72.9% TID decreasing to 67.8%, and SOG baseline 68.7% TID decreasing to 65.9%). Moreover, although REM sleep stage increased in all three groups, the NG group had the smallest increase (NG 4.3%, OG 9.2% and OSG 10.5%) and final total REM TIB percentage (NG 12.6%, OG 15.0% and OSG 15.2%) (37). However, CPAP treatment in obese patients may increase neural respiratory drive (38), which may increase the frequency of arousals (39), thus increasing wakefulness-sleep transition times and worsening PLMS. Therefore, PLMI may increase in non-obese patients due to an increase in the proportion of NREM sleep. Whereas in obese patients, although improvements in PLMS may decrease the proportion of NREM sleep and increase REM sleep, this may be offset by an increase in the frequency of neural-respiratory-drive-related arousals and wakefulness-sleep transition times. In summary, our main results showed that BMI was not significantly correlated with CPAP treatment. However, recent studies (16, 3739) support our subgroup findings that an increase in PLMI was associated with CPAP treatment in patients with a BMI <30 kg/m2, but not in those with a BMI ≥30 kg/m2.

In conclusion, PLMI was significantly increased after CPAP treatment. An increase in PLMI could be predicted using factors including baseline high AHI, baseline high AI and BMI <30 kg/m2. Baseline PLMI <5 (or without baseline PLMS) was a possible pathophysiological predictor. Although ferritin level may be a more convincing predictor, further studies are needed to investigate this hypothesis. Patients with OSA and more predictive factors may have a higher risk of severe PLMS after CPAP treatment.

There are some limitations to the current study. First, the wide variety of heterogeneity among the included studies, such as differences in subject selection criteria (one of the enrolled studies used PLMI >5 on polysomnography with CPAP as their inclusion criteria and excluded patients without PLMS after CPAP), different ages, comorbidities of the enrolled patients, different scoring criteria of sleep disordered breathing and PLMS, different equipment to measure PLMS (i.e. traditional polysomnography and actigraphy), and different methods of titrating CPAP (i.e. manual titration and auto-titration). Second, night-to-night variability of PLMI and PLMAI in two consecutive nights occurred in 27 and 19% of PLMS, respectively (40), and it is unclear whether night-to-night variability may worsen or improve after long-term CPAP therapy. In this study, the interval between the first polysomnography for diagnosis and polysomnography with CPAP ranged from 1 day to 2–7 months. The night-to-night variability per se and the different intervals between the two polysomnography sessions may have affected comparisons of absolute changes in PLMI. Third, the PLMI may differ between different sleep stages and time of night. One study conducted standard polysomnography during the first half of the night and polysomnography with CPAP during the second half of the night, which may also have affected the results. Fourth, not all of the included studies confirmed PLM using the standard method (i.e. polysomnography), and some used actigraphy to measure PLM, which may not be sufficiently sensitive. Fifth, since there are two subtypes of sleep apnea (i.e. central sleep apnea and obstructive sleep apnea), it would be clinically helpful to conduct subgroup analysis based on these two subtypes. However, because few studies provided such detailed subtype information, further subgroup analysis could not be done. Sixth, because of the natural limitation of a meta-analysis, we could only observe the phenomenon of changes in PLMI related to CPAP treatment, but could not directly conclude the physiopathology responsible for these changes. Finally, and most importantly, every study except that by Budhiraja et al. (35) performed peri-CPAP treatment. It is possible that the increase in PLMI with CPAP treatment could be related to a circadian variation. In addition, the increase in PLMI could just be related to a tendency to be higher in the morning hours rather than the influence of CPAP. It should be noted that Budhiraja et al. (35) (a randomized controlled trial and also the third largest study in the meta-analysis) did not show any difference in the change in PLMI when comparing sham CPAP to active CPAP over a 6-month period.

Conclusion

Conclusion: The main findings of this meta-analysis were that patients with OSA had a significant increase in PLMI after CPAP treatment, while there were no significant changes in PLMAI. AHI and AI were strongly and positively correlated with changes in PLMI. In addition, PLMI was also increased in the patients with PLMI <5 and BMI <30 kg/m2. The proposed predictors may serve as indicators to qualitatively predict an increase in PLMI, and they may serve as qualitative predictive indicators of changes in PLMI after CPAP usage.

Future recommendation: Future studies analyzing the quantitative relationship between PLMI and these indicators may be warranted.

Author Contributions

T-CL, P-TT, and B-YZ performed manuscript drafting, data analysis, and visualization. M-NW, T-YC, Y-WC, and P-YY contributed to concept formation, data curation, literature review, study design, and manuscript revision. C-YH was responsible for collecting information from the other authors, manuscript major revision, software analysis, and manuscript submission. All authors contributed to the article and approved the submitted version.

Conflict of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's Note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary Material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fneur.2022.817009/full#supplementary-material

Abbreviations

AASM, American Association of Sleep Medicine; AHI, apnea-hypopnea index; AI, arousal index; BMI, body mass index; CI, confidence interval; CPAP, continuous positive airway pressure; ES, effect size; ESS, Epworth Sleepiness Scale; ODI, oxygen desaturation index; OSA, obstructive sleep apnea; PLMS, periodic limb movements of sleep; PLMAI, periodic limb movements with arousal index; PLMI, periodic limb movement index; PRISMA, Preferred Reporting Items for Systematic Reviews and Meta-Analyses; REM, rapid eye movement; TST, total sleep time.

References

1. Punjabi NM. The epidemiology of adult obstructive sleep apnea. Proc Am Thorac Soc. (2008) 5:136–43. doi: 10.1513/pats.200709-155MG

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Hornyak M, Feige B, Riemann D, Voderholzer U. Periodic leg movements in sleep and periodic limb movement disorder: prevalence, clinical significance and treatment. Sleep Med Rev. (2006) 10:169–77. doi: 10.1016/j.smrv.2005.12.003

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Baran AS, Richert AC, Douglass AB, May W, Ansarin K. Change in periodic limb movement index during treatment of obstructive sleep apnea with continuous positive airway pressure. Sleep. (2003) 26:717–20. doi: 10.1093/sleep/26.6.717

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Epstein LJ, Kristo D, Strollo PJ Jr, Friedman N, Malhotra A, Patil SP, et al. Clinical guideline for the evaluation, management and long-term care of obstructive sleep apnea in adults. J Clin Sleep Med. (2009) 5:263–76. doi: 10.5664/jcsm.27497

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Jonas DE, Amick HR, Feltner C, Weber RP, Arvanitis M, Stine A. Screening for obstructive sleep apnea in adults: evidence report and systematic review for the US preventive services task force. JAMA. (2017) 317:415–33. doi: 10.1001/jama.2016.19635

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Stoohs RA, Blum HC, Suh BY, Guilleminault C. Misinterpretation of sleep-breathing disorder by periodic limb movement disorder. Sleep Breath. (2001) 5:131–7. doi: 10.1055/s-2001-17431

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Drigo R, Fontana M, Coin A, Ferraresso A, Enzo E, Zambotto FM. APAP titration in patients with mild to moderate OSAS and periodic limb movement syndrome. Monaldi Arch Chest Dis. (2006) 65:196–203. doi: 10.4081/monaldi.2006.549

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Noseda A, Nouvelle M, Lanquart JR, Kempenaers CH, De Maertelaer V, Linkowski R, et al. (2002). High leg motor activity in sleep apnea hypopnea patients: efficacy of clonazepam combined with nasal CPAP on polysomnographic variables. Respir Med. (2002) 96:693–9. doi: 10.1053/rmed.2002.1333

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Ferri R, Fulda S, Allen RP, Zucconi M, Bruni O, Chokroverty S, et al. World Association of Sleep Medicine (WASM) 2016 standards for recording and scoring leg movements in polysomnograms developed by a joint task force from the International and the European Restless Legs Syndrome Study Groups (IRLSSG and EURLSSG). Sleep Med. (2016) 26:86–95. doi: 10.1016/j.sleep.2016.10.010

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Benz RL, Pressman MR, Wu X. Periodic limb movements in sleep revealed by treatment of sleep apnea with continuous positive airway pressure in the advanced chronic kidney disease population. Clin Nephrol. (2011) 76:470–4. doi: 10.5414/CN107072

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Hoffstein V. Review of oral appliances for treatment of sleep-disordered breathing. Sleep Breath. (2007) 11:1–22. doi: 10.1007/s11325-006-0084-8

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Huang TC, Tseng PT, Wu MN, Stubbs B, Carvalho AF, Lin PY. Periodic limb movements during sleep are associated with cardiovascular diseases: a systematic review and meta-analysis. J Sleep Res. (2019) 28:e12720. doi: 10.1111/jsr.12720

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Aritake-Okada S, Namba K, Hidano N, Asaoka S, Komada Y, Usui A. Change in frequency of periodic limb movements during sleep with usage of continuous positive airway pressure in obstructive sleep apnea syndrome. J Neurol Sci. (2012) 317:13–6. doi: 10.1016/j.jns.2012.03.013

PubMed Abstract | CrossRef Full Text | Google Scholar

14. American Academy of Sleep Medicine. International Classification of Sleep Disorders. 3rd ed. Darien, IL: American Academy of Sleep Medicine (2014).

Google Scholar

15. Hall AB, Ziadi MC, Leech JA, Chen SY, Burwash IG, Renaud J. Effects of short-term continuous positive airway pressure on myocardial sympathetic nerve function and energetics in patients with heart failure and obstructive sleep apnea: a randomized study. Circulation. (2014) 130:892–901. doi: 10.1161/CIRCULATIONAHA.113.005893

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Van Herzeele C, Dhondt K, Roels SP, Raes A, Groen LA, Hoebeke P. Periodic limb movements during sleep are associated with a lower quality of life in children with monosymptomatic nocturnal enuresis. Eur J Pediatr. (2015) 174:897–902. doi: 10.1007/s00431-014-2474-4

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. (2021)372, n71. doi: 10.1136/bmj.n71

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Shea BJ, Reeves BC, Wells G, Thuku M, Hamel C, Moran J. AMSTAR 2: a critical appraisal tool for systematic reviews that include randomised or non-randomised studies of healthcare interventions, or both. BMJ. (2017) 358:j4008. doi: 10.1136/bmj.j4008

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Jadad AR, Moore RA, Carroll D, Jenkinson C, Reynolds DJ, Gavaghan DJ, et al. Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials. (1996) 17:1–12. doi: 10.1016/0197-2456(95)00134-4

PubMed Abstract | CrossRef Full Text | Google Scholar

20. American Sleep Disorders SRS Association. EEG arousals: scoring rules and examples: a preliminary report from the sleep disorders atlas task force of the American Sleep Disorders Association. Sleep. (1992) 15:173–84. doi: 10.1093/sleep/15.2.174

CrossRef Full Text | Google Scholar

21. Coleman RM. Periodic leg movements in sleep (nocturnal myoclonus) and restless leg syndrome. In: C. Guilleminault, editor. Sleep and Waking: Indications and Techniques. Boston: Butterworths (1982), p. 265–96.

Google Scholar

22. Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. BMJ. (2003) 327:557–60. doi: 10.1136/bmj.327.7414.557

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Higgins JP, Green S. Recommendations on testing for funnel plot asymmetry. In: Higgins JP, Green S, , editors. Cochrane Handbook for Systematic Reviews of Interventions. Cochrane Library. Hoboken, NJ: John Wiley & Sons (2011).

Google Scholar

24. Egger M, Davey Smith G, Schneider M, Minder C. Bias in meta-analysis detected by a simple, graphical test. BMJ. (1997) 315:629–34. doi: 10.1136/bmj.315.7109.629

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Duval S, Tweedie R. Trim and fill: a simple funnel-plot-based method of testing and adjusting for publication bias in meta-analysis. Biometrics. (2000) 56:455–63. doi: 10.1111/j.0006-341X.2000.00455.x

PubMed Abstract | CrossRef Full Text | Google Scholar

26. Tobias A. Assessing the influence of a single study in meta-analysis. Stata Tech Bull. (1999) 47:15–7.

Google Scholar

27. Davey J, Turner RM, Clarke MJ, Higgins JP. Characteristics of meta-analyses and their component studies in the Cochrane Database of Systematic Reviews: a cross-sectional, descriptive analysis. BMC Med Res Methodol. (2011) 11:160. doi: 10.1186/1471-2288-11-160

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Yamashiro Y, Kryger MH. Acute effect of nasal CPAP on periodic limb movements associated with breathing disorders during sleep. Sleep. (1994) 17:172–5. doi: 10.1093/sleep/17.2.172

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Fry JM, DiPhillipo MA, Pressman MR. Periodic leg movements in sleep following treatment of obstructive sleep apnea with nasal continuous positive airway pressure. Chest. (1989) 96:89–91. doi: 10.1378/chest.96.1.89

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Carelli G, Krieger J, Calvi-Gries F, Macher JP. Periodic limb movements and obstructive sleep apneas before and after continuous positive airway pressure treatment. J Sleep Res. (1999) 8:211–6. doi: 10.1046/j.1365-2869.1999.00153.x

PubMed Abstract | CrossRef Full Text | Google Scholar

31. Hedli LC, Christos P, Krieger AC. Unmasking of periodic limb movements with the resolution of obstructive sleep apnea during continuous positive airway pressure application. J Clin Neurophysiol. (2012) 29:339–44. doi: 10.1097/WNP.0b013e3182624567

PubMed Abstract | CrossRef Full Text | Google Scholar

32. Wu MN, Lai CL, Liu CK, Yen CW, Liou LM, Hsieh CF. Basal sympathetic predominance in periodic limb movements in sleep after continuous positive airway pressure. Sleep Breath. (2018) 22:1005–12. doi: 10.1007/s11325-018-1620-z

PubMed Abstract | CrossRef Full Text | Google Scholar

33. Mwenge GB, Rougui I, Rodenstein D. Effect of changes in periodic limb movements under cpap on adherence and long term compliance in obstructive sleep apnea. Acta Clin Belg. (2018) 73:191–8. doi: 10.1080/17843286.2017.1405137

PubMed Abstract | CrossRef Full Text | Google Scholar

34. Murase K, Azuma M, Tachikawa R, Minami T, Matsumoto T, Hamada S. Prospective associations of sleep apnea, periodic limb movements, and plasma fibrinogen level. Sleep Breath. (2020). doi: 10.1007/s11325-020-02147-5

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Budhiraja R, Javaheri S, Pavlova MK, Epstein LJ, Omobomi O, Quan SF. Prevalence and correlates of periodic limb movements in OSA and the effect of CPAP therapy. Neurology. (2020) 94:e1820–7. doi: 10.1212/WNL.0000000000008844

PubMed Abstract | CrossRef Full Text | Google Scholar

36. Yang XR, Ren R, Li X, He JM, Xue XF, Zhang Y. [Effects of continuous positive airway pressure on periodic limb movements during sleep in patients with obstructive sleep apnea]. Zhonghua yi xue za zhi. (2018) 98:1570–3. doi: 10.3760/cma.j.issn.0376-2491.2018.20.008

PubMed Abstract | CrossRef Full Text | Google Scholar

37. Antczak J, Horn B, Richter A, Bodenschatz R, Latuszynski K, Schmidt EW. The differences in sleep profile changes under continuous positive airway pressure (CPAP) therapy between non-obese, obese and severely obese sleep apnea patients. J Physiol Pharmacol. (2012) 63:263–9.

PubMed Abstract | Google Scholar

38. Xiao S, Bastianpillai J, Ratneswaran C, Pengo MF, Luo Y, Jolley CJ. Continuous positive airway pressure and breathlessness in obese patients with obstructive sleep apnea: a pilot study. Sleep. (2016) 39:1201–10. doi: 10.5665/sleep.5832

PubMed Abstract | CrossRef Full Text | Google Scholar

39. Berry RB, Gleeson K. Respiratory arousal from sleep: mechanisms and significance. Sleep. (1997) 20:654–75. doi: 10.1093/sleep/20.8.654

PubMed Abstract | CrossRef Full Text | Google Scholar

40. Hornyak M, Kopasz M, Feige B, Riemann D, Voderholzer U. Variability of periodic leg movements in various sleep disorders: implications for clinical and pathophysiologic studies. Sleep. (2005) 28:331–5. doi: 10.1093/sleep/28.3.331

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: continuous positive airway pressure (CPAP), periodic limb movement during sleep, obstructive sleep apnea, sleep medicine, respiration

Citation: Lin T-C, Zeng B-Y, Wu M-N, Chen T-Y, Chen Y-W, Yeh P-Y, Tseng P-T and Hsu C-Y (2022) Changes in Periodic Limb Movements of Sleep After the Use of Continuous Positive Airway Pressure Therapy: A Meta-Analysis. Front. Neurol. 13:817009. doi: 10.3389/fneur.2022.817009

Received: 17 November 2021; Accepted: 06 May 2022;
Published: 02 June 2022.

Edited by:

Thomas Penzel, Charité Universitätsmedizin Berlin, Germany

Reviewed by:

Mikhail G. Poluektov, I.M. Sechenov First Moscow State Medical University, Russia
Stuart F. Quan, Harvard Medical School, United States

Copyright © 2022 Lin, Zeng, Wu, Chen, Chen, Yeh, Tseng and Hsu. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Ping-Tao Tseng, ducktseng@gmail.com; Chung-Yao Hsu, cyhsu@kmu.edu.tw

These authors have contributed equally to this work and share first authorship

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.