Skip to main content

ORIGINAL RESEARCH article

Front. Med., 08 February 2024
Sec. Ophthalmology
This article is part of the Research Topic Updates in Ocular Therapeutics and Surgery - Volume III View all 11 articles

Ophthalmic surgeries on post mortem porcine eyes with picosecond ultrashort laser pulses

Michael Krber,
&#x;Michael Körber1,2*Jakob FellingerJakob Fellinger3Milan FritscheMilan Fritsche1Andreas GieseAndreas Giese1Konstantina KostourouKonstantina Kostourou4Daniel KopfDaniel Kopf3Manfred KottckeManfred Kottcke1Francesco LucianiFrancesco Luciani5Josef M. Schmidbauer,Josef M. Schmidbauer2,5Jonathan WenkJonathan Wenk1Bernd BraunBernd Braun1
  • 1Applied Mathematics, Physics and Humanities, Nuremberg Institute of Technology, Nuremberg, Germany
  • 2Paracelsus Medical University, Nuremberg, Germany
  • 3MONTFORT Laser GmbH, Götzis, Austria
  • 4NANEO Precision IBS Coatings GmbH, Lindau, Germany
  • 5Clinic of Ophthalmology, Klinikum Nürnberg Nord, Nuremberg, Germany

Purpose: This work demonstrates significant advantages in ophthalmic surgeries through the use of picosecond ultrashort laser pulses instead of state-of-the-art nanosecond laser pulses. These ultrashort lasers shall serve as universal tools more effectively combining advantages of high precision, low impact and economic advantages compared to existing instruments.

Methods: As samples, we used post-mortem porcine eyes on which we performed the experiments with both picosecond and nanosecond lasers. Performed surgeries were laser iridotomy, (post-) cataract treatment/capsulotomy and selective laser-trabeculoplasty. Pulse widths were between 12 ps and 220 ns with pulse energies between 30 μJ and 10 mJ at 532 nm and 1,064 nm. Additionally, we investigated accompanying shock waves, cavitation bubbles, and heat effects during the ablation processes.

Results: For all surgeries, significant differences were observed between picosecond and nanosecond pulses: It was possible to scale the pulse energy down to 10 of microjoules rather than requiring millijoules, and resulting tissue ablations are much more precise, more deterministic and less frayed. The shock wave and cavitation bubble investigation revealed major differences in pressure between picosecond pulses (0.25 MPa, 50 μJ) and nanosecond pulses (37 MPa, 5 mJ). The heat input during ablation could be lowered by two orders of magnitude.

Conclusion: Picosecond ultrashort laser pulses show substantial benefits for several ophthalmic surgeries, with regard to ablation precision, shock wave generation and heat input. They are better than state-of-the-art ophthalmic nanosecond lasers in all aspects tested.

1 Introduction

In ophthalmology, laser sources are commonly used for non-invasive/incisionless or minimally invasive surgeries. These lasers are mainly neodymium doped yttrium-aluminum-garnet (Nd:YAG) lasers. They emit comparatively long pulse widths in the nanosecond (ns) range that lead to a non-negligible heat input during surgical tissue ablation. The energy input then causes immediate boiling, expansion and evaporation of the tissue. This results in acoustic shock waves and non-deterministic tissue ablation with collateral damage of surrounding tissue. Consequently, the ablation achieved is much larger than the actual laser spot, which can lead to side effects and additional clinical patterns such as ghost images, iris bleeding, corneal endothelial damage or retinal detachment. Furthermore, the tissue ablation with ns laser sources depends on the linear absorption properties of the tissue and therefore on the color of the eye (17). However, such unintended results can be counteracted by using ultrashort pulses (USP) (813). The main advantage of these pulses—which have a pulse width of a few picoseconds or less—is to be near the regime of cold material ablation. This physical effect results from the very short pulse width and the associated high peak intensity. Due to the high peak intensities, ionization and plasma formation occur through multi-photon processes when a single laser pulse interacts with the tissue. This interaction time is too short to transfer energy to the atomic lattice of the material, as the heat diffusion time in the lattice is much longer than the duration of the laser pulse. This results in material removal with very little heat input. Another advantage of cold material ablation is that the non-linear absorption properties of the material is predominant, which is why the ablation is almost independent of the material properties in terms of linear absorption, reflection and transmission (1417). Consequently, USP lasers should ablate tissue very precisely and deterministically independent of eye color (10, 1823). However, currently available ultrashort pulse lasers, such as those used for LASIK (laser in situ keratomileusis), are very expensive and therefore economically not appropriate for small surgeries such as laser iridotomy and post-cataract treatment. For this reason, ns laser sources are state-of-the-art in ophthalmology.

This paper discusses the use of an ultrashort pulse laser source emitting in the picosecond regime for ophthalmic surgeries and evaluates the potential benefits of these lasers, particularly for iridotomy, capsulotomy/post-cataract treatment and selective laser-trabeculoplasty (SLT). This research was motivated by ultra-compact Q-switched picosecond lasers recently becoming available, combining the advantages of the low price of currently used ns laser sources with cold material ablation capabilities of high-end femtosecond lasers (24, 25).

Laser iridotomy as treatment of narrow angle glaucoma involves piercing the iris next to the Schlemm’s canal to create a new floating path for the eye fluid. This piercing is done with a series of laser pulses that are applied to the tissue via an ophthalmic slit lamp laser system. The energy ranges from 1 to 10 mJ per pulse for the ns laser sources currently in use. The same laser source is used for post-cataract treatment, where the posterior lens capsule is opened with laser pulses applied in a cross-shaped pattern. Both treatments may lead to adverse effects and additional clinical patterns such as frayed edges, collateral damage and strong shock wave generation. The latter takes place, because tissue ablation with laser sources is accompanied by a laser-induced optical breakdown in the laser focus (8). Such breakdown leads to plasma formation and the generation of shock waves caused by cavitation formation inside the material (tissue). The cavitation bubble then oscillates as long as enough energy is available in the breakdown region. Here, the initial breakdown and every cavitation bubble collapse lead to a separate shock wave. Therefore, several shock waves are generated per laser pulse and alter the mechanisms of laser ablation by affecting tissue adjacent to the target. This leads to bigger ablation areas and—if the shock waves are strong enough—to additional undesired side effects such as retinal detachment after iridotomy or (post-) cataract surgery (2, 5, 2628). Therefore, it is necessary to ablate tissue with as low pulse energy as possible. With ultrashort pulse ps laser sources, the same treatment can be performed with much lower energy input. Furthermore, it can be shown that USP lasers lead to much less intense shock wave formation than ns lasers due to the aforementioned cold material ablation (8, 9, 2933). The same principle can be applied to SLT, whereby the trabecular meshwork (TM) is irradiated with a 532 nm laser source. Here, the laser pulses ablate some TM tissue and also stimulate the remaining TM tissue so that previously restricted immune reactions are made viable again. Furthermore, the lasers can also be used to penetrate the TM completely down to the Schlemm’s canal to create a drainage (3436). Both surgical methods can be performed with lower pulse energy and higher precision by using ultrashort pulse laser sources.

To investigate and prove our hypotheses, the research was executed as follows: First, the method and its application in laser iridotomy, post-cataract treatment/capsulotomy and SLT are described. Then, a quantitative analysis of shock waves associated with the treatment is presented. Finally, this paper investigates heat input of ultrashort laser pulses on biological tissue (porcine iris) and on aluminum plates, to gain a better understanding of the ablation processes and heat effects inside the tissue.

2 Materials and methods

This section describes the laser sources and methods used for the different experiments, namely ophthalmic surgeries, shock wave and cavitation bubble examination, and heat investigation.

2.1 Laser sources

Different laser beam sources are used for the experiments, emitting sech2 (picosecond laser) and gaussian (nanosecond lasers) shaped pulses with pulse widths between 12 ps and 220 ns and pulse energies between 30 μJ and 10 mJ, optionally at 1064 nm and 532 nm wavelength. Here, the nanosecond lasers are used as reference laser sources for state-of-the-art results. For all beam sources, the pulse energy can be adjusted manually with a polarizing beam splitter and a wave-plate up to the specific maximum. The following list describes the laser sources in more detail:

Laser 1: USP laser source with 12 ps pulse width: USP laser system consisting of a passively mode-locked Nd:YVO4 (neodymium-doped yttrium orthovanadate) oscillator and an Nd:YVO4 regenerative amplifier (37). The laser system emits a 1,064 nm pulse train with an adjustable pulse repetition rate between 1 Hz and 300 kHz, a pulse energy of up to 164 μJ, and a pulse width of 12 ps. The laser output can additionally be frequency doubled with a KTP (potassium titanyl phosphate—KTiOPO4) nonlinear crystal, leading to a wavelength of 532 nm with a pulse energy conversion efficiency of up to 70%.

Laser 2: ns laser source with 1.6 ns pulse width: 1.6 ns, 20 Hz quasi-continuous-wave (QCW) passively Q-switched (PQS) Nd:YAG (neodymium-doped yttrium aluminum garnet) laser source with pulse energies up to 7 mJ at 1064 nm from MONTFORT Laser GmbH, Götzis, Austria.

Laser 3: ns laser source with 8 ns pulse width: 8 ns, 10 Hz actively Q-switched laser source with pulse energies up to 50 mJ at 1064 nm from MONTFORT Laser GmbH, Götzis, Austria. The laser output can additionally be frequency doubled with a KTP nonlinear crystal, leading to a wavelength of 532 nm.

Laser 4: ns laser source with adjustable pulse width: 20 W, 1062 nm pulsed fiber master oscillator power amplifier (MOPA) laser from JENOPTIK Laser GmbH, Jena, Germany (‘JenLas®fiber ns 20 advanced single mode’). It emits in continuous wave (cw) operation or pulsed operation with pulse widths between 15 ns and 220 ns with maximum pulse energies between 68 and 570 μJ, respectively.

2.2 Method for ophthalmic surgeries

In contrast to ophthalmic surgical methods with special eye attachment optics/system, the different laser beams are focused on the samples via the following beam delivery system: This system consists of a 60 mm plano convex focusing lens, an x-y-z-translation stage for sample positioning, two laser diodes for laser focus alignment (FP-D-532-1-C-F from Laser Components GmbH, Olching, Germany), and a stereo microscope as visualization device for real-time observation and magnification (Stemi 508 trino from Carl Zeiss Microscopy GmbH, Oberkochen, Germany). This set-up is based on slit-lamp laser beam delivery systems such as used in clinics and is similar in function. For part of the capsulotomies and SLT, a laser scanner set-up is used, consisting of a two-axis laser scanner head (SS-II-15 [Y] D2 from Raylase GmbH, Wessling, Germany) with the F-Theta flat field objective S4LFT3046/328 (Sill Optics GmbH & Co. KG, Wendelstein, Germany) with a focal length of 50 mm. Since these components of the set-ups are designed for the near infrared (NIR), a second set-up for 532 nm was built, using another 60 mm plano convex focusing lens and the scanner head SS-IIE-15 [DY] D2 (Raylase GmbH, Wessling, Germany) with the F-Theta flat field objective S4LFT4066/292 (Sill Optics GmbH & Co. KG, Wendelstein, Germany) with a focal length of 67.2 mm. Focusing results in a focal spot diameter of about 25 μm for all focusing set-ups. This leads to fluences of 8 J/cm2 (12 ps, 50 μJ) and 800 J/cm2 (8 ns, 5 mJ), and peak intensities of 587 GW/cm2 and 94 GW/cm2, respectively.

The tissue samples used are post mortem porcine eyes, which are processed about 4 h after excision. The eyes are moistened with water before, during and after all surgeries. The iridotomy and capsulotomy surgeries were performed as open sky surgeries (with prior cornea removal) for better comparability without the influence of the cornea. SLT surgeries were performed in two ways: First, on a bisected porcine eye (removed lens) with the slit-lamp set-up to focus the laser beams directly on the trabecular meshwork (TM) without the necessity of a clinically used gonioscope. Second, on an exposed trabecular meshwork with the scanner set-up. For this, the eyes were prepared in such a way that the cornea, about 2 mm of the sclera around the cornea, and the TM were preserved. This is comparable to pieces of human donor corneas, where a part of the sclera and the TM are also still attached. The lasers can then be focused directly on the TM from the posterior side. Visualization, examination and measurement of the results are carried out using high-resolution light microscopy and scanning electron microscopy (SEM). For the latter, a special sample preparation and drying method is applied to the tissue samples that avoid water inside the tissue to boil and expand under vacuum in the plasma coating machine and the SEM. This would lead to warpage/deformation/distortion and destruction of the tissue. The preparation method starts with 1,5-pentanedial (glutaraldehyde solution 50% in water (5.6 mol); Sigma-Aldrich, St. Louis, United States) for protein linkage and tissue fixation. The tissue is then buffered with a phosphate buffer of pH = 7.0 (Bernd Kraft, Duisburg, Germany) and subsequently placed in an alcoholic solution in ascending concentration (start: 20%/80% ethanol/water; end: 100% ethanol; gradation: 10% ethanol—water: purified water; ethanol: Ethanol absolute ≥99.5% from VWR International, Radnor, United States). The last step before air drying is soaking the tissue in 1,1,1-Trimethyl-N-(trimethylsilyl)silanamine (hexamethyldisilazane, HMDS; Sigma-Aldrich, St. Louis, United States). The samples of the exposed TM for SLT are soaked in pure ethanol only and subsequently air dried, because the cornea and sclera lead to a high stiffness even without fixation. Some of the capsule samples are strictly air dried during compression to avoid warpage/deformation/distortion.

All samples can then be metal-coated (metal: gold/palladium—SC502-314B from Quorum Technologies, Laughton, United Kingdom) and visualized by SEM. For this, the plasma coating machine Q150R ES (Quorum Technologies, Laughton, United Kingdom) and the SEM JSM 6510 (Jeol Ltd., Tokyo, Japan) are used. Light microscope images were taken using the incident light microscope Axio Lab.A1, the transmitted light microscope Primo Star and the stereo microscope Stemi 508 trino, all from Carl Zeiss AG, Oberkochen, Germany.

In total, the research was performed on about 400 porcine eyes with over 1,000 surgeries (approx. 800 iridotomies, 25 capsulotomies, 200 SLTs).

2.3 Method for shock wave and cavitation bubble investigation

Shock waves generated by laser pulses were investigated using the following method and set-up (see Figure 1): The different laser sources are focused via a laser mirror and an f = 40 mm aspherical plano-convex lens in a basin (74 mm × 74 mm × 33 mm; l × w × h) filled with distilled water. Focusing results in a diameter of about 10 μm, leading to fluences of 50 J/cm2 (12 ps, 50 μJ) and 5 kJ/cm2 (8 ns, 5 mJ), and peak intensities of 5.5 TW/cm2 and 587 GW/cm2, respectively. The laser input results in an optical breakdown and shock waves, which are visualized using a streak camera system. The field of observation has a diameter of approximately 20 mm, roughly corresponding to the distance between laser focus and retina.

Figure 1
www.frontiersin.org

Figure 1. Shock wave measurement set-up. 1: switch for different laser sources; 2: laser mirror; 3: focusing lens; 4: water bath; 5: laser induced breakdown with shock waves; 6: illumination source; 7: camera; 8: function generator; 9: needle hydrophone; 10: oscilloscope.

The light source of the system, a collimated pulsed green laser diode PLT5 510 B1-3 (OSRAM GmbH, München, Germany), is synchronized to the pulse repetition rate of the breakdown laser. The phase delay between the laser pulse and the illumination pulse can be adjusted manually with a ns-increment to illuminate different shock wave propagation points. Both synchronization and delay adjustment are performed with a waveform generator (33500B from Agilent Technologies, Inc., Santa Clara, United States). Recording is done with a digital camera (RX100 from Sony, Tokyo, Japan). In addition to the photographs, a 2 mm diameter needle hydrophone with attenuator, pre-amplifier and DC-coupler (Precision Acoustics Ltd., Dorchester, United Kingdom) is placed next to the breakdown below the water surface. It serves as a receiver of the shock wave fronts. For visualization and measurement, it is connected to an oscilloscope (MSO64 from Tektronix, Inc., Beaverton, United States, 6 GHz bandwidth). The result of this measurement is a quantitative intensity profile of the shock waves as a function of the laser parameters.

For cavitation bubble investigation, the streak camera set-up was modified (see Figure 2): The water bath was replaced by a 2.5 mL polystyrene macro cuvette and the illumination source was replaced by a 1,062 nm cw laser source (Laser 4, see Sec. 2.1), triggered and modulated with a Pockels cell. The camera was changed to the system camera VEXU-24 M (Baumer Electric AG, Frauenfeld, Switzerland). Both the Pockels cell and the camera are triggered by the waveform generator to the pulse repetition rate of the breakdown laser. This set-up provides a minimum illumination time of 5 ns, which is limited by the switching time of the Pockels cell.

Figure 2
www.frontiersin.org

Figure 2. Cavitation bubble measurement set-up. 1: switch for different laser sources; 2: laser mirror; 3: focusing lens; 4: water cuvette; 5: laser breakdown with cavitation bubble; 6: illumination source; 7: camera; 8: function generator; 9: Pockels cell.

2.4 Method for heat investigation

The heat input of the different laser sources was investigated using the thermal imaging camera optris Xi 400 (Optris GmbH, Berlin, Germany). The different lasers were focused via the laser scanner set-up either on black anodized aluminum plates or on porcine eye irises. The scanner scribed a 5 mm long line with 10 mm/s. The emissivity was set to to εeye = 0.98 for the iris tissue (equal to water and skin) and εalu = 0.67 for anodized aluminum (38). The measurements are then compared to simulations computed with MATLAB (The MathWorks, Inc., Natick, United States) following the approach of Ansari et al. (39).

3 Results

This section includes results of the different ophthalmic surgeries, shock wave and cavitation bubble examination, and heat investigation.

3.1 Laser Iridotomy

The study revealed a major variation in size, shape, quality and reproducibility of iridotomies with different pulse widths. A comparison of four different pulse widths (12 ps, 8 ns, 15 ns, 220 ns) is shown in Figure 3. The images show typical results for each pulse width. In each case, the SEM magnification factor is 500 and the scale bars are 50 μm. While results (A) and (B) for 12 ps, 1 kHz at 1064 nm and 532 nm are very good, showing small and well-defined holes, the nanosecond results (C)–(F) with different pulse lengths, pulse energies, repetition rates, and wavelengths show frayed edges, ejection of ablated material, and large areas of altered surrounding tissue. The latter is attributed to the higher temperatures incurred through these pulse widths. Furthermore, Figure 4G shows an ideal result, which was achieved with the 12 ps USP laser source, with 40 μJ pulse energy, 1 kHz repetition rate, and 1 s irradiation time. Here, the quality is almost perfect: The ablated hole has very sharp edges and appears almost as if punched. The scale bar is also 50 μm but the SEM magnification factor is 230.

Figure 3
www.frontiersin.org

Figure 3. Iridotomies on post mortem porcine eye irises with pulse widths of 12 ps, 8 ns, 15 ns and 220 ns. Images (A–F) show typical results for each pulse width. Magnification factor is 500 and scale bars are 50 μm. Image (G) shows an ideal result for an iridotomy (SEM mag. Factor is 230).

Figure 4
www.frontiersin.org

Figure 4. Cuts (left) and piercings (right) in anterior lens capsules of porcine eyes with low-energy 12 ps USP laser pulses.

In addition to the far better defined laser processing, the pulse energy necessary for piercing the iris could be reduced to several 10 of microjoules (between 30 μJ and 70 μJ) when using USP laser pulses compared to several millijoules (1 mJ to 10 mJ) when using ns laser sources. To achieve complete penetration of the iris, approximately 1,000 USP pulses, dependent on the pulse energy, are required (and thus an exposure time of 1 s at 1 kHz repetition rate). The ablation per pulse is considerably lower than with nanosecond pulses, where a few pulses (with 5 mJ pulse energy) are sufficient to achieve complete penetration of the iris.

3.2 Capsulotomy

With ps pulses, well-defined capsulotomies can be performed in addition to iridotomies. As seen in Figure 4, precise cutting (left) and piercing (right) of the anterior lens capsule of porcine eyes is possible with 12 ps laser pulses—without tearing the remaining capsule. Similar to iridotomy, pulse energies between 30 μJ and 70 μJ prove to be suitable.

Figure 5 shows a comparison of capsulotomies with (A) 8 ns, 3 mJ and (B) 12 ps, 50 μJ. Both capsulotomies are performed on dissected anterior lens capsules. The lasers were focused on the capsules via the laser scanner head set-up. The capsulotomy diameter was set to 4 mm and the laser processing speed was set to 2.5 mm/s, resulting in a spot spacing of 5 μm for the 1 kHz ultrashort pulse train and 250 μm for the 10 Hz, 8 ns pulse train. Due to high energy input with accompanying high shock impact of the ns laser pulses, the processing speed could not be reduced to achieve the same spot spacing as for the USP pulses, since the capsule would have been torn right away. A comparison of the images reveals a big difference in capsules shape and cut quality. While the ns capsulotomy is torn and has frayed edges due to the high pulse energy required for these pulse widths, the USP capsulotomy is almost perfectly round with sharp and smooth cutting edges. The lower images (C) and (D) show higher magnifications of the respective capsulotomies cutting edges, visualized by light microscopy. In (C) the cutting edge is marked with a black arrow, since the capsule is folded over due to the high shock input. Additionally, Figure 5E shows an SEM visualization of the cutting edge of (B) with a magnification factor of 1,500. Here, the edge is very sharp and flat, which is comparable to state-of-the-art femtosecond and manual capsulotomies (19, 23).

Figure 5
www.frontiersin.org

Figure 5. Anterior capsules with 4 mm capsulotomies with (A) 8 ns, 3 mJ and (B) 12 ps, 50 μJ. Images (C,D) show light microscopy magnifications of respective cutting edges [magnified areas are marked in red in (A,B)]. The black arrow in (C) marks the edge, since it is folded over. Image (E) shows an SEM visualization of the cutting edge of the 12 ps, 50 μJ capsulotomy.

3.3 SLT—selective laser-trabeculoplasty

Similar to the results of the iridotomy and the capsulotomy, SLT is possible with the 12 ps USP laser pulses at much lower pulse energies compared to ns pulses, namely 30 μJ to 70 μJ instead of 1 mJ (40). A result with 12 ps, 50 μJ at 1064 nm is shown in Figure 6, where “champagne bubbles” can be seen to the left of the green target laser (marked with black arrow). These bubbles appeared during the surgery and are considered an indicator of successful treatment. All tested pulse energies between 30 μJ and 70 μJ led to comparable results.

Figure 6
www.frontiersin.org

Figure 6. SLT with 1,064 nm, 12 ps and 50 μJ on a bisected porcine eye. “Champagne bubbles” (marked with black arrow) to the left of the green target lasers are considered an indicator of successful treatment.

Figure 7 shows four typical results of SLTs in exposed trabecular meshwork with (A) picosecond ultrashort laser pulses and (B)–(D) nanosecond laser pulses. All SEM visualizations were taken with a magnification factor of 200. As with the other surgeries, the differences between USP and ns pulses are significant. Regardless of wavelength and pulse energy, 12 ps produce a small hole with sharp edges and clear boundaries. In contrast, all results with nanosecond pulses show large holes with poor quality. Furthermore, the heat affected zones are strongly pronounced around the holes.

Figure 7
www.frontiersin.org

Figure 7. Typical SLT results on exposed porcine eye’s trabecular meshwork using 12 ps USP (A) and nanosecond (B–D) laser sources. The magnification factor is 200 and the scale bars are 100 μm.

3.4 Shock wave and cavitation bubble investigations

Figure 8 shows the visualization of a laser induced shock wave in water—real image on the left and false color image on the right. The laser induced breakdown leads to a shock wave, which is reflected on a steel target. Here, the breakdown was induced with 147 μJ, 12 ps at 1064 nm from the top. Figure 9 shows a color-inverted photograph of a laser induced breakdown (dark spot) with 161 μJ, 12 ps at 1064 nm together with a cavitation bubble (brighter cycle) and a typical jet formation to the left of the bubble.

Figure 8
www.frontiersin.org

Figure 8. Visualization of a shock wave in water induced with a 147 μJ, 12 ps, 1,064 nm pulse train; left: real image; right: false color representation. 1: Laser induced breakdown; 2: Shock wave; 3: Shock wave reflection; 4: Steel target for reflection. The laser was irradiated from the top (41).

Figure 9
www.frontiersin.org

Figure 9. Photograph (inverted colors) of a cavitation bubble with 161 μJ, 12 ps at 1064 nm. The dark spot (1) results from the laser induced plasma and the brighter circle from the cavitation bubble (2). The maximum bubble radius is 198 μm. Moreover, a typical jet formation (3) can be seen left of the bubble. The laser was irradiated from the left (42, 43).

The shock wave pressure was measured with a hydrophone. Figure 10 shows a typical hydrophone measurement visualized with an oscilloscope. Peak 1 is the initial breakdown with expansion of the cavitation bubble—this is the shock wave of the laser induced breakdown (LIB). Peak 2 is the signal from the first bubble collapse and peak 3 from the second bubble collapse. Dependent on the breakdown energy, and therefore on the pulse energy, the cavitation bubble oscillation of expansion and collapse repeats more often. Here, the pulse energy of 5 mJ at a pulse width of 1.6 ns led to three (detectable) shock waves.

Figure 10
www.frontiersin.org

Figure 10. Shock wave pressure measurement with a needle hydrophone. Peak 1: initial breakdown with expansion of the cavitation bubble; Peak 2: first bubble collapse; Peak 3: second bubble collapse. The laser induced breakdown is initiated with 5 mJ pulse energy and 1.6 ns pulse width.

The needle hydrophone measurements are shown in Figure 11 (logarithmic scale due to major differences in amplitude). Here, the normalized hydrophone signal (voltage) Uhyd is plotted for 12 ps and 1.6 ns pulse width as a function of the pulse energy Epulse and the hydrophone distance dhyd to the focal spot. The pulse energies were chosen accordingly to the results from the ophthalmic surgeries, as 50 μJ are typical for USP and 3 mJ and 6 mJ are typical for ns laser sources. 100 μJ at 12 ps are measured to gain information about energy dependency at a fixed pulse width. As can be seen, there are large differences of a factor of 25 in average for ns/USP lasers between the different parameters.

Figure 11
www.frontiersin.org

Figure 11. Normalized shock wave signal Uhyd as a function of the hydrophone distance dhyd for different pulse widths τpulse and pulse energies Epulse.

To determine the actual pressure of the shock waves, the hydrophone voltages are converted to pressure values via spectrum analysis. In Figure 12, the LIB shock wave and the first collapse shock wave pressure are plotted for different pulse energies. The pulse width is 12 ps and the distance between the hydrophone and the breakdown area is 6 mm. This measurement results in higher pressures for higher pulse energies with a maximum pressure of 0.6 MPa at 161 μJ pulse energy.

Figure 12
www.frontiersin.org

Figure 12. Shock wave pressure pshock for LIB and collapse shock waves for different pulse energies Epulse at 6 mm distance to the breakdown. The pulse width is 12 ps.

A similar measurement is made for pulse energies between 0.2 mJ and 5 mJ at 1.6 ns pulse width (Figure 13). The distance between the needle hydrophone and the laser induced breakdown is 17 mm. The measurement was done for the LIB, the 1st and the 2nd collapse shock wave. It results in much stronger shock wave pressures compared to 12 ps pulses—even for longer distance. For example, a 50 μJ, 12 ps laser pulse leads to a maximum pressure of 0.25 MPa while a 5 mJ, 1.6 ns laser pulse generates 37 MPa.

Figure 13
www.frontiersin.org

Figure 13. Shock wave pressures pshock for the first, second and third shock wave per pulse for different pulse energies Epulse at 17 mm distance to the breakdown. The pulse width is 1.6 ns.

3.5 Heat investigation

Large differences between treatment with picosecond and nanosecond pulses also exist with respect to heat input and transfer around the laser focus (see Figure 14). On the left, the test is shown on porcine eyes for pulse widths of 12 ps, 8 ns, 15 ns and 220 ns as used for ophthalmic surgeries (Figures 14A,C,E,G), on the right, for comparison on black anodized aluminum (Figures 14B,D,F,H). As mentioned in the methods (see Sec. 2.4), the lasers scribed a 5 mm long line with 10 mm/s. The respective temperature before irradiation P, maximum temperature during irradiation M, and heating difference H in °C are indicated. Results (A) and (C), as well as (B) and (D) are the same, with different temperature scales for both better visibility and comparability to the nanosecond results. While 12 ps only lead to a marginal heating of a few degrees which is not even recognizable in the images (C) and (D), both 15 ns and 220 ns lead to a heating of more than 150°C. Again, the pulse energies for the various pulse widths were selected as required for the treatment.

Figure 14
www.frontiersin.org

Figure 14. Temperature measurement on porcine eyes (A,C,E,G) and black anodized aluminum (B,D,F,H) with different laser parameters. The values given are the temperature before irradiation P, the maximum temperature during irradiation M, and the heating difference H in °C. Measurement (A) and (C) as well as (B) and (D) are the same, with different temperature scales. The lasers scribed a 5 mm long line with 10 mm/s.

Figure 15 presents simulations of the temperature change on a water surface for different pulse widths. The simulations are calculated for one single pulse each, so that the heat accumulation for several pulses has no effect. As displayed in Figure 15 left (temperature change as function of pulse energy), there is a large difference for pulse widths of 12 ps, 100 ps, 1 ns, 15 ns and 220 ns: The longer the pulse width and the higher the pulse energy, the higher the temperature change. As expected, utilization of low energy ultrashort pulses results in much lower heat inputs than high energy nanosecond pulses (2.5 K change for 12 ps, 50 μJ and 250 K change for 1 ns, 570 μJ). This simulation in general agrees with the experimental results. It should be noted that the simulation reflects the maximum temperature at the center of the laser focus, while the measurement averages over a larger area of space (about 0.15 mm2). On the right in Figure 15, the temperature change is plotted as a function of distance to the laser spot. Here, 12 ps, 50 μJ pulses lead to a heat-affected zone of about 300 μm, while it is about 900 μm for 220 ns, 50 μJ and even larger for 220 ns, 570 μJ. Pulses with 8 ns, 3 mJ show a similar heat-affected zone than 12 ps. However, the much higher temperature change of 1800 K (8 ns) compared to 2.5 K (12 ps) would affect the surrounding tissue, e.g., due to the aforementioned stronger shock waves and instant evaporation.

Figure 15
www.frontiersin.org

Figure 15. Simulated temperature changes on a water surface. Left: for different pulse widths τpulse and pulse energies Epulse; Right: radial to the laser spot for 220 ns, 8 ns and 12 ps pulse width.

Whereas the impact of a single ps laser pulse is significantly lower compared to nanosecond pulses, the question remains whether or not this holds true for the required pulse train of some hundreds to thousand pulses. The thermo mechanical response of tissue to pulsed irradiation was investigated by, e.g., Vogel et al. (44) and Yakovlev et al. (45). According to these studies typical thermal relaxation times are in the range of a few microseconds. In comparison to the temporal distance of consequent pulses, which is in the millisecond range for ps lasers, this relaxation time ensures temperature and stress confinement in any case.

4 Discussion and conclusion

As expected, the use of ultrashort pulses in ophthalmic surgeries led to significant improvements with regard to ablation precision, surgery quality, and impact on surrounding tissue. By using picosecond pulses instead of nanosecond pulses, the pulse energy could be reduced from a few millijoules to 10 of microjoules (an on-average reduction factor of 100). As with femtosecond lasers, this regime is referred to as cold material processing. At a pulse width of 12 ps, all of the aforementioned ocular procedures, i.e., laser-iridotomy, (post-) cataract treatment/capsulotomy, and selective laser-trabeculoplasty, could be successfully performed in an energy range of 30 μJ to 70 μJ at both 532 nm and 1,064 nm. Furthermore, the shock wave and cavitation bubble formation during the surgeries could be reduced by a factor of x25 on average due to the shorter pulse widths and lower pulse energies. Finally, the thermal studies (experimental and simulative) revealed a significant reduction in both the temperature change and the temperature spreading (spatially and temporally) between picosecond and nanosecond laser pulses.

The recent availability of ultra-compact picosecond lasers—due to new physical approaches in laser physics—could lead to smaller and simpler laser sources. Therefore, the size- and cost-related disadvantages of former picosecond lasers are counteracted, as these systems consist of a two-stage set-up with two different laser resonators. The new approach is just one single micro-chip resonator with (if needed) subsequent pulse compression and/or pulse amplification (24, 25). Thus, the new technology is much simpler than existing systems, leading to a cost reduction and prices comparable to that of state-of-the-art ophthalmic nanosecond lasers.

Compared to former results with picosecond laser sources, we achieved at least comparable, mostly better results. Now it must be confirmed whether these results are also possible with the novel picosecond laser sources, which will be the next step in our project-plan. Furthermore, all results must then be transferred to human tissue ex vivo, in order to test the ablation possibilities as closely as possible to in vivo samples.

In conclusion, the use of picosecond ultrashort pulse laser sources in ophthalmology leads to substantial improvements and could be the stable basis for a very precise, universal tool for current ophthalmic surgeries and new surgical methods. Therefore, the next step will be to investigate the transferability of results from animal to pathological human tissue, and eventually a clinical study.

Data availability statement

The original contributions presented in the study are included in the article/supplementary material, further inquiries can be directed to the corresponding author.

Ethics statement

Ethical approval was not required for the study involving animals in accordance with the local legislation and institutional requirements because the used porcine eyes were exclusively from slaughterhouse waste.

Author contributions

MiK: Conceptualization, Formal analysis, Investigation, Methodology, Visualization, Writing – original draft. JF: Resources, Writing – review & editing. MF: Investigation, Resources, Writing – review & editing. AG: Investigation, Resources, Writing – review & editing. KK: Funding acquisition, Resources, Writing – review & editing. DK: Funding acquisition, Resources, Writing – review & editing. MaK: Conceptualization, Funding acquisition, Methodology, Supervision, Validation, Writing – review & editing. FL: Formal analysis, Investigation, Methodology, Resources, Validation, Writing – review & editing. JS: Funding acquisition, Methodology, Supervision, Validation, Writing – review & editing. JW: Investigation, Writing – review & editing. BB: Conceptualization, Funding acquisition, Methodology, Project administration, Supervision, Validation, Writing – review & editing.

Funding

The author(s) declare financial support was received for the research, authorship, and/or publication of this article. This project has received funding from the Eurostars-2 joint program with co-funding from the European Union Horizon 2020 research and innovation program - grant number E! 113846. The funder was not involved in the study design, collection, analysis, interpretation of data, the writing of this article or the decision to submit it for publication.

Conflict of interest

DK and JF are employed by MONTFORT Laser GmbH. KK is employed by NANEO Precision IBS Coatings GmbH.

The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Bazard, MC, Guldenfls, Y, and Raspiller, A. Early endothelial complications after treatment using a neodymium-Yag laser. J Fr Ophthalmol. (1989) 12:17–23.

Google Scholar

2. Wu, SC, Jeng, S, Huang, SC, and Lin, SM. Corneal endothelial damage after neodymium:YAG laser iridotomy. Ophthalmic Surg Lasers. (2000) 31:411–6. doi: 10.3928/1542-8877-20000901-09

PubMed Abstract | Crossref Full Text | Google Scholar

3. Hsiao, CH, Hsu, CT, Shen, SC, and Chen, HS. Midterm follow-up of Nd:YAG laser iridotomy in Asian eyes. Ophthalmic Surg Lasers Imaging. (2003) 34:291–8. doi: 10.3928/1542-8877-20030701-04

Crossref Full Text | Google Scholar

4. Kumar, H, Mansoori, T, Warjri, GB, Somarajan, BI, Bandil, S, and Gupta, V. Lasers in glaucoma. Indian J Ophthalmol. (2018) 66:1539–53. doi: 10.4103/ijo.IJO_555_18

PubMed Abstract | Crossref Full Text | Google Scholar

5. Ono, T, Iida, M, Sakisaka, T, Minami, K, and Miyata, K. Effect of laser peripheral iridotomy using argon and neodymium-YAG lasers on corneal endothelial cell density: 7-year longitudinal evaluation. Jpn J Ophthalmol. (2018) 62:216–20. doi: 10.1007/s10384-018-0569-6

PubMed Abstract | Crossref Full Text | Google Scholar

6. Agarwal, G, Kumar, S, and Malik, VK. Effect of Nd:YAG laser posterior capsulotomy on corneal endothelial cell count in relation to the power of laser used. Int J Sci Res. (2019) 8:1178–83.

Google Scholar

7. Saha, BC, Kumari, R, Sinha, BP, Ambasta, A, and Kumar, S. Lasers in Glaucoma: an overview. Int Ophthalmol. (2021) 41:1111–28. doi: 10.1007/s10792-020-01654-4

Crossref Full Text | Google Scholar

8. Vogel, A, Busch, S, Jungnickel, K, and Birngruber, R. Mechanisms of intraocular photodisruption with picosecond and nanosecond laser pulses. Lasers Surg Med. (1994) 15:32–43. doi: 10.1002/lsm.1900150106

PubMed Abstract | Crossref Full Text | Google Scholar

9. Vogel, A, Capon, MR, Asiyo-Vogel, MN, and Birngruber, R. Intraocular photodisruption with picosecond and nanosecond laser pulses: tissue effects in cornea, lens, and retina. Invest Ophthalmol Vis Sci. (1994) 35:3032–44.

PubMed Abstract | Google Scholar

10. Momma, C, Nolte, S, Chichkov, B, Tuennermann, A, and von Alvensleben, F. Precise laser ablation with ultrashort pulses. Appl Surf Sci. (1997) 109-110:15–9. doi: 10.1016/S0169-4332(96)00613-7

Crossref Full Text | Google Scholar

11. Kim, BM, Feit, MD, Rubenchik, AM, Joslin, EJ, Celliers, PM, Eichler, J, et al. Influence of pulse duration on ultrashort laser pulse ablation of biological tissues. J Biomed Opt. (2001) 6:332–8. doi: 10.1117/1.1381561

PubMed Abstract | Crossref Full Text | Google Scholar

12. Mayerhofer, R. The shorter, the better: materials processing with ultra short pulsed lasers. Laser Tech J. (2011) 8:44–7. doi: 10.1002/latj.201190025

Crossref Full Text | Google Scholar

13. Mayerhofer, R, May, AB, and Serbin, J. Is it cold enough, yet? Laser Tech J. (2016) 13:20–3. doi: 10.1002/latj.201600008

Crossref Full Text | Google Scholar

14. Du, D, Liu, X, Korn, G, Squier, J, and Mourou, G. Laser-induced breakdown by impact ionization in SiO2 with pulse widths from 7 ns to 150 fs. Appl Phys Lett. (1994) 64:3071–3. doi: 10.1063/1.111350

Crossref Full Text | Google Scholar

15. Pronko, PP, Dutta, SK, Squier, J, Rudd, JV, Du, D, and Mourou, G. Machining of sub-micron holes using a femtosecond laser at 800 nm. Opt Commun. (1995) 114:106–10. doi: 10.1016/0030-4018(94)00585-I

Crossref Full Text | Google Scholar

16. Chichkov, BN, Momma, C, Nolte, S, von Alvensleben, F, and Tünnermann, A. Femtosecond, picosecond and nanosecond laser ablation of solids. Appl Phys A Mater Sci Process. (1996) 63:109–15. doi: 10.1007/s003390050359

Crossref Full Text | Google Scholar

17. Cheng, J, Liu, CS, Shang, S, Liu, D, Perrie, W, Dearden, G, et al. A review of ultrafast laser materials micromachining. Opt Laser Technol. (2013) 46:88–102. doi: 10.1016/j.optlastec.2012.06.037

Crossref Full Text | Google Scholar

18. Palanker, DV, Blumenkranz, MS, Andersen, D, Wiltberger, M, Marcellino, G, Gooding, P, et al. Femtosecond laser-assisted cataract surgery with integrated optical coherence tomography. Sci Transl Med. (2010) 2:58ra85–11. doi: 10.1126/scitranslmed.3001305

PubMed Abstract | Crossref Full Text | Google Scholar

19. Friedman, NJ, Palanker, DV, Schuele, G, Andersen, D, Marcellino, G, Seibel, BS, et al. Femtosecond laser capsulotomy. J Cataract Refract Surg. (2011) 37:1189–98. doi: 10.1016/j.jcrs.2011.04.022

Crossref Full Text | Google Scholar

20. Nagy, ZZ, Kránitz, K, Takacs, AI, Miháltz, K, Kovács, I, and Knorz, MC. Comparison of intraocular lens decentration parameters after femtosecond and manual capsulotomies. J Refract Surg. (2011) 27:564–9. doi: 10.3928/1081597X-20110607-01

PubMed Abstract | Crossref Full Text | Google Scholar

21. Donaldson, KE, Braga-Mele, R, Cabot, F, Davidson, R, Dhaliwal, DK, Hamilton, R, et al. Femtosecond laser-assisted cataract surgery. J Cataract Refract Surg. (2013) 39:1753–63. doi: 10.1016/j.jcrs.2013.09.002

Crossref Full Text | Google Scholar

22. Grewal, DS, Schultz, T, Basti, S, and Dick, HB. Femtosecond laser-assisted cataract surgery-current status and future directions. Surv Ophthalmol. (2016) 61:103–31. doi: 10.1016/j.survophthal.2015.09.002

Crossref Full Text | Google Scholar

23. Kang, MJ, Lee, YE, Choi, JS, and Joo, CK. Ideal parameters for femto-second laser- assisted anterior capsulotomy: animal studies. PloS One. (2018) 13:1–8. doi: 10.1371/journal.pone.0190858

Crossref Full Text | Google Scholar

24. Kohl, H, Kulcsar, G, Kopf, D, and Braun, B. 12-ps megawatt peak power pulses out of a single laser oscillator with nonlinear pulse compression SPIE Photonics West - Solid State Lasers XXVIII - Sess 3 Pap. nr. 10896-19. (2019).

Google Scholar

25. Giese, A, Körber, M, Kostourou, K, Kopf, D, Kottcke, M, Lohbreier, J, et al. Passively Q-switched sub-100 ps Yb3+:YAG/Cr4+:YAG microchip laser: experimental results and numerical analysis. Proc. SPIE 12399, solid state lasers XXXII Technol. Dev Dent. (2023) 123990S:9057. doi: 10.1117/12.2649057

Crossref Full Text | Google Scholar

26. Schmidbauer, JM, Vargas, LG, Peng, Q, Escobar-Gomez, M, Werner, L, Arthur, SN, et al. Posterior Capsule Opacification. Int Ophtalmol Clin. (2001) 41:109–31. doi: 10.1097/00004397-200107000-00010

Crossref Full Text | Google Scholar

27. Haug, SJ, and Bhisitkul, RB. Risk factors for retinal detachment following cataract surgery. Curr Opin Ophthalmol. (2012) 23:7–11. doi: 10.1097/ICU.0b013e32834cd653

Crossref Full Text | Google Scholar

28. Choi, A, Kim, K, and Lee, C. Serous retinal detachment following laser peripheral Iridotomy for the angle closure secondary to posterior Scleritis. Keimyung Med J. (2017) 36:52–7. doi: 10.0000/kmj.2017.36.1.52

Crossref Full Text | Google Scholar

29. Lauterborn, W. Optische Kavitation. Phys J. (1976) 32:553–63. doi: 10.1002/phbl.19760321208

Crossref Full Text | Google Scholar

30. Puliafito, CA, and Steinert, RF. Short-pulsed Nd:YAG laser microsurgery of the eye: biophysical considerations. IEEE J Quantum Electron. (1984) 20:1442–8. doi: 10.1109/JQE.1984.1072343

Crossref Full Text | Google Scholar

31. Hammer, DX, Thomas, RJ, Noojin, GD, Rockwell, BA, Kennedy, PK, and Roach, WP. Experimental investigation of ultrashort pulse laser-induced breakdown thresholds in aqueous media. IEEE J Quantum Electron. (1996) 32:670–8. doi: 10.1109/3.488842

Crossref Full Text | Google Scholar

32. Petkovšek, R, Močnik, G, and Možina, J. Optodynamic characterization of shock waves after laser induced breakdown in water. Conf Lasers Electro-Optics Eur - Tech Dig. (2005) 13:4107–12. doi: 10.1109/CLEOE.2005.1568419

PubMed Abstract | Crossref Full Text | Google Scholar

33. Liang, XX, Linz, N, Freidank, S, Paltauf, G, and Vogel, A. Comprehensive analysis of spherical bubble oscillations and shock wave emission in laser-induced cavitation. J Fluid Mech. (2022) 940:A5. doi: 10.1017/jfm.2022.202

Crossref Full Text | Google Scholar

34. Schwartz, AL, and Anderson, DR. Trabecular surgery. Arch Ophthalmol. (1974) 92:134–8. doi: 10.1001/archopht.1974.01010010140012

Crossref Full Text | Google Scholar

35. Kramer, TR, and Noecker, RJ. Comparison of the morphologic changes after selective laser trabeculoplasty and argon laser trabeculoplasty in human eye bank eyes. Ophthalmology. (2001) 108:773–9. doi: 10.1016/S0161-6420(00)00660-6

PubMed Abstract | Crossref Full Text | Google Scholar

36. Gupta, M, Heo, JY, Gong, H, Cha, E, Latina, M, and Rhee, DJ. Morphologic and cellular changes induced by selective laser Trabeculoplasty. Clin Ophthalmol. (2022) 16:1383–90. doi: 10.2147/OPTH.S342787

PubMed Abstract | Crossref Full Text | Google Scholar

37. Körber, M. Master’s thesis - Iridotomy as glaucoma treatment using a novel ultrashort pulse laser source. Technische Hochschule Nürnberg Georg Simon Ohm: Nürnberg (2019).

Google Scholar

38. [Dataset] ‘Divest’. Available at: www.vizaar-xtra.de Emissionsgrad-Tabelle - date Accessed: 19.09.2023 (2023).

Google Scholar

39. Ansari, MA, and Zakeri, M. Blind localization of heating in neural tissues induced by a train of the infrared pulse laser. J Lasers Med Sci. (2019) 10:264–7. doi: 10.15171/jlms.2019.43

PubMed Abstract | Crossref Full Text | Google Scholar

40. Sacks, ZS, Dobkin-Bekman, M, Geffen, N, Goldenfeld, M, and Belkin, M. Non-contact direct selective laser trabeculoplasty: light propagation analysis. Biomed Opt Express. (2020) 11:2889–904. doi: 10.1364/boe.390849

PubMed Abstract | Crossref Full Text | Google Scholar

41. Körber, M, Fritsche, M, Giese, A, Kopf, D, Kottcke, M, Luciani, F, et al. Ophthalmological surgeries with a novel ultrashort pulse laser source In:. Paracelsus virtual Sci. Get together 2021. Nürnberg: PMU Nürnberg (2021)

Google Scholar

42. Wenk, J. Bachelor’s thesis - quantitative analyse laserinduzierter Kavitationsblasen. Nürnberg: Tech. rep., Technische Hochschule Nürnberg Georg Simon Ohm (2022).

Google Scholar

43. Körber, M, Fritsche, M, Giese, A, Kostourou, K, Kopf, D, Kottcke, M, et al. Iridotomy and capsulotomy on porcine eyes with ultrashort laser pulses in the picosecond regime. Proc. SPIE 12360, Ophthalmic Technol. (2023) XXXIII:123600J. doi: 10.1117/12.2650151

Crossref Full Text | Google Scholar

44. Vogel, A, and Venugopalan, V. Mechanisms of pulsed laser ablation of biological tissues. Chem Rev. (2003) 103:577–644. doi: 10.1021/cr010379n

Crossref Full Text | Google Scholar

45. Yakovlev, E, Shandybina, G, and Shamova, A. Modelling of the heat accumulation process during short and ultrashort pulsed laser irradiation of bone tissue. Biomed Opt Express. (2019) 10:3030–40. doi: 10.1364/boe.10.003030

PubMed Abstract | Crossref Full Text | Google Scholar

Keywords: iridotomy, capsulotomy, SLT, picosecond laser, shock waves, glaucoma, cataract

Citation: Körber M, Fellinger J, Fritsche M, Giese A, Kostourou K, Kopf D, Kottcke M, Luciani F, Schmidbauer JM, Wenk J and Braun B (2024) Ophthalmic surgeries on post mortem porcine eyes with picosecond ultrashort laser pulses. Front. Med. 11:1345976. doi: 10.3389/fmed.2024.1345976

Received: 28 November 2023; Accepted: 30 January 2024;
Published: 08 February 2024.

Edited by:

Horace Massa, Hôpitaux universitaires de Genève (HUG), Switzerland

Reviewed by:

Bojan Pajic, University of Novi Sad, Serbia
Azhar Zam, New York University Abu Dhabi, United Arab Emirates

Copyright © 2024 Körber, Fellinger, Fritsche, Giese, Kostourou, Kopf, Kottcke, Luciani, Schmidbauer, Wenk and Braun. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Michael Körber, bWljaGFlbC5rb2VyYmVyQHRoLW51ZXJuYmVyZy5kZQ==

ORCID: Michael Körber, http://orcid.org/0000-0003-3753-0657

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.