Intra-subject variability in oscillometry correlates with acute rejection and CLAD post-lung transplant

\r\nAnastasiia VasilevaAnastasiia Vasileva1Nour HanafiNour Hanafi1Ella HusztiElla Huszti2John MatelskiJohn Matelski2Natalia Belousova,Natalia Belousova1,3Joyce K. Y. Wu,Joyce K. Y. Wu1,4Tereza Martinu,Tereza Martinu1,3Rasheed GhanyRasheed Ghany3Shaf Keshavjee,Shaf Keshavjee3,5Jussi Tikkanen,Jussi Tikkanen1,3Marcelo Cypel,Marcelo Cypel3,5Jonathan C. Yeung,Jonathan C. Yeung3,5Clodagh M. Ryan,Clodagh M. Ryan1,4Chung-Wai Chow,*Chung-Wai Chow1,3*
  • 1Division of Respirology, Department of Medicine, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
  • 2Biostatistics Research Unit, University Health Network, Toronto, ON, Canada
  • 3Toronto Lung Transplant Program, Ajmera Multi-Organ Transplant Unit, University Health Network, Toronto, ON, Canada
  • 4Pulmonary Function Laboratory, University Health Network, Toronto, ON, Canada
  • 5Division of Thoracic Surgery, Department of Surgery, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada

Background: Chronic lung allograft dysfunction (CLAD) is the major cause of death post-lung transplantation, with acute cellular rejection (ACR) being the biggest contributing risk factor. Although patients are routinely monitored with spirometry, FEV1 is stable or improving in most ACR episodes. In contrast, oscillometry is highly sensitive to respiratory mechanics and shown to track graft injury associated with ACR and its improvement following treatment. We hypothesize that intra-subject variability in oscillometry measurements correlates with ACR and risk of CLAD.

Methods: Of 289 bilateral lung recipients enrolled for oscillometry prior to laboratory-based spirometry between December 2017 and March 2020, 230 had ≥ 3 months and 175 had ≥ 6 months of follow-up. While 37 patients developed CLAD, only 29 had oscillometry at time of CLAD onset and were included for analysis. These 29 CLAD patients were time-matched with 129 CLAD-free recipients. We performed multivariable regression to investigate the associations between variance in spirometry/oscillometry and the A-score, a cumulative index of ACR, as our predictor of primary interest. Conditional logistic regression models were built to investigate associations with CLAD.

Results: Multivariable regression showed that the A-score was positively associated with the variance in oscillometry measurements. Conditional logistic regression models revealed that higher variance in the oscillometry metrics of ventilatory inhomogeneity, X5, AX, and R5-19, was independently associated with increased risk of CLAD (p < 0.05); no association was found for variance in %predicted FEV1.

Conclusion: Oscillometry tracks graft injury and recovery post-transplant. Monitoring with oscillometry could facilitate earlier identification of graft injury, prompting investigation to identify treatable causes and decrease the risk of CLAD.

1. Introduction

Chronic lung allograft dysfunction (CLAD) is the main cause of death beyond 1 year post-transplant and develops in 50–70% of recipients by 5 years. Acute cellular rejection (ACR) is the most significant factor that contributes to graft injury leading to CLAD (13). There are no effective treatments for CLAD. While retransplantation is an option, it is associated with lower maximum lung function achieved and higher post-transplant mortality (4). Therefore, early identification of graft injury and treatment of risk factors contributing to CLAD are crucial to improving long-term survival.

Patients are routinely monitored with spirometry, specifically the forced expiratory volume in 1 s (FEV1) with the goal of identifying ACR and graft injury from other causes. However, a 10% drop in FEV1 is only 60% sensitive to ACR (57). Respiratory oscillometry is a pulmonary function modality that is exquisitely sensitive to respiratory mechanics. We recently showed that oscillometry tracks changes in lung mechanics associated with graft injury in biopsy-proven, clinically significant ACR and improvement following treatment with augmented immunosuppression (8). Furthermore, we observed the magnitude of the abnormal oscillometry measurements to correlate with the severity of ACR as quantified by the A-grade (8). While our center performs surveillance transbronchial biopsies at pre-determined timepoints during the first 2 years post-transplant to identify clinically silent ACR, many centers do not and rely primarily on spirometry for patient monitoring.

Studies in asthma and chronic obstructive pulmonary disease (COPD) populations found that intra-subject variations in the longitudinal oscillometry measurements are predictive of future asthma and COPD exacerbations (913) and that variance in the oscillometry metric of inspiratory reactance was highly correlated with respiratory symptoms in COPD (14). These and our observations in lung transplant recipients (8) led us to hypothesize that the intra-subject variability in oscillometry measurements could be a marker of ongoing graft injury that is associated with cumulative burden of ACR and risk of CLAD.

2. Patient population and methods

This prospective longitudinal observational study was approved by the University Health Network (UHN) Research Ethics Board (REB# 17-5652). All eligible double lung transplant recipients are enrolled at the first visit to Toronto General Hospital Pulmonary Function Laboratory after transplant for oscillometry prior to routine spirometry. Oscillometry is conducted using the tremoflo-C100 (Thorasys, Montreal, Canada). We previously reported detailed inclusion/exclusion criteria and the standard operating, quality control and assurance protocols for oscillometry and pulmonary function testing (PFT) (8, 15). All testing is conducted in accordance with international guidelines (16, 17). Routine post-lung transplant care includes weekly PFT for the first 3 months, then at 6, 9, 12, 18, 24 months and annually thereafter, and surveillance bronchoscopies with broncho-alveolar lavage and transbronchial biopsies at 2, 6 and 12 weeks up to late 2018, and at 4 and 12 weeks thereafter, followed by 6, 9, 12, 18 and 24 months after transplant. During the COVID-19 pandemic, surveillance bronchoscopes were suspended between late March 2020 and late 2021.

The specific oscillometry parameters of interest were those previously found to be associated with ACR (8): R5 (resistance at 5 Hz, a measure of total lung resistance), R5-19 (the difference between the resistance at 5 and 19 Hz, a metric of small airway function), X5 (reactance at 5 Hz) and AX (area of reactance). R5-19, X5 and AX are also metrics of ventilatory inhomogeneity (1822).

Demographic and clinical data were obtained from electronic medical records and/or the Toronto lung transplant database. The A-score is defined as the sum of biopsy A-grades divided by the total number of transbronchial biopsies where a numeric A-grade is available (23). CLAD was diagnosed according to the 2019 ISHLT guidelines (24).

2.1. Study population

For the current study, we included 234 of the 289 patients enrolled from 28 December 2017 to 13 March 2020, excluding patients who had < 3 months follow-up (n = 19), consistently indeterminate transbronchial biopsy grade (n = 18), no biopsies (n = 8), died or dropped-out in the first 3 months (n = 13) (Figure 1). For the A-score analysis, only patients who had 1 or more years of follow-up were included in the analysis. For the CLAD analysis, additional criteria were applied to exclude patients who did not meet the definition of CLAD nor that of CLAD-free. Details of these criteria are below.

FIGURE 1
www.frontiersin.org

Figure 1. Patient recruitment, enrolment and study cohort. A-score = mean of A-grades of all transbronchial biopsies performed excluding those with indeterminate transbronchial biopsy grade; A-score zero, A-score low (i.e., > 0 but < 0.5) and A-score high (A ≥ 0.05); FEV1, forced expiratory volume in 1 s; CLAD, chronic lung allograft dysfunction; LTx, lung transplant. Possible CLAD–most recent FEV1 is < 80% of baseline but there is no repeat PFT or repeat PFT is < 3 weeks later; probable CLAD–two FEV1 values < 80% of baseline, > 3 weeks but < 3 months apart; no CLAD FEV1 drop–20% FEV1 drop deemed to not be CLAD; definite CLAD–persistent decline (≥ 20%) in measured FEV1 from the baseline value for at least 3 months; InsPFT-patient had < 3 measurements of spirometry in total; undefined–insufficient information to determine whether CLAD is present or was present at the time of death; missing Osc/biopsies–oscillometry or biopsies were not performed at time of CLAD onset.

2.2. Statistical analyses

2.2.1. Association with acute cellular rejection

To investigate associations between oscillometry and the cumulative burden of clinically apparent ACR at 1 year, we excluded 112 patients with < 1 year of follow-up (Figure 1). For the remaining 122 patients, individual intra-subject variance of each spirometry/oscillometry parameter was calculated as the average squared deviation from the mean of all measurements up to 365 ± 30 days post-transplant (Supplementary Equation 1). A minimum of 3 paired visits was required for inclusion. The same cut-off dates were used to calculate the A-score; biopsies performed within 7 days of spirometry/oscillometry were included, as bronchoscopy frequently occurs up to 7 days after spirometry. Group comparisons were conducted using Student’s t-test for normally distributed continuous variables, Wilcoxon test for non-normally distributed continuous variables and Pearson’s chi-square test for categorical variables.

We performed linear regression analyses to assess the association between variability in oscillometry parameters and A-score. A separate model was fitted for each spirometry/oscillometry parameter, where each variance parameter served as the outcome, and the A-score served as the predictor of primary interest. Log transformation of the oscillometry variance parameters was performed to stabilize residual variance. The first regression analysis considered spirometry/oscillometry variance as the response variable and A-score as a categorical predictor. The second, dose-responsiveness regressions considered the A-score as a continuous predictor using data from all patients with an A-score > 0, which was log-transformed. We performed univariable and multivariable linear regression models, controlling for the variables with a conceivable biological association with graft injury: sex, recipient age at transplant, primary disease, primary hospitalization length of stay, CMV match status, as well as the number of biopsies to account for differential biopsy follow-up between patients.

2.2.2. Association with CLAD status

To investigate the association between variability in oscillometry and CLAD status, we used conditional logistic regression models, wherein CLAD-free individuals were time-matched to CLAD cases to account for differences in duration of follow-up. We excluded patients with possible/probable CLAD (n = 19), where CLAD adjudication was not possible (n = 4) and CLAD-free patients with < 6 months of follow-up (n = 34). Of the remaining 177 patients, 19 patients were excluded as oscillometry or biopsies were not performed at time of or within 30 days of CLAD onset. A total of 129 CLAD-free patients had a paired spirometry/oscillometry test that was time-matched within 14 days of a CLAD patient. All patients had to have a minimum of 3 paired spirometry-oscillometry tests and at least one gradable biopsy during the time-matched period to be included in the final analyses. Each CLAD case had a minimum of 2 and a maximum of 7 CLAD-free matches in order to optimize the relatively small sample size. We performed univariable followed by multivariable regressions. For the multivariable regressions, we selected primary disease, actual human leukocyte antigen (HLA) crossmatch status at transplant, and continuous A-score for inclusion as covariates due to known biological associations with CLAD. All statistical analysis was performed using R Version 4.0.3 (25).

3. Results

3.1. Association of oscillometry measurements with acute cellular rejection

3.1.1. Patient demographics and clinical characteristics with at least 1 year of follow-up

Comparison of patients with consistently no rejection on transbronchial biopsies (A-score = 0, n = 55), those with an A-score between 0 and < 0.5 (n = 34) and A-score ≥ 0.5 (n = 33) revealed no significant differences in the demographic characteristics (Table 1).

TABLE 1
www.frontiersin.org

Table 1. Demographics and clinical characteristics of patients with ≥ 1 year follow-up.

The duration of hospitalization for transplantation was significantly longer in the A-score = 0 group (p = 0.033; Table 2) who also had fewer transbronchial biopsies per patient compared to other groups (p < 0.001). Most high A-grade biopsies occur early post-transplant, with 88% of the A-grade ≥ 2 ACR and 73% A-grade ≥ 1 ACR identified within the first 4 months. Beyond 1 year, only 7 episodes of A1 and no A2 rejections occurred (Supplementary Table 1). The number of paired oscillometry-spirometry tests was similar between the groups (Table 2).

TABLE 2
www.frontiersin.org

Table 2. Peri-operative and post-transplant characteristics of the cohort with ≥ 1 year follow-up.

3.1.2. Associations between A-score and intrasubject variance in oscillometry and spirometry at 1 year

In agreement with findings from previous studies (26), our data shows that most ACR episodes occur within the first year. Therefore, we evaluated the relationship between the A-score and variance in the oscillometry at the 1 year mark in the 122 patients who had ≥ 1 year of follow-up. We considered the A-score as a categorical variable with 3 groups: zero, low (A-score between 0 and 0.5) and high (A-score ≥ 0.5). Setting the high A-score group as the reference value, univariable analysis revealed significant differences between the low and high A-score groups in the variance in X5, AX, and R5-19 (p < 0.05) (Table 3). The absolute oscillometry and spirometry measurements at the 1 year-mark were not significantly different between the groups, and thus, not used in the analyses (Supplementary Table 2).

TABLE 3
www.frontiersin.org

Table 3. Association of categorical A-score with the variance in lung function measurements at 1 year.

Next, we conducted multivariable linear regression analysis, adjusting for variables known to impact lung function and/or graft rejection (recipient age, sex, primary disease and CMV serostatus matching), primary hospital length of stay and the number of transbronchial biopsies. The multivariable linear regressions revealed comparable results to the univariable analysis, with a significant difference between the low and high A-score groups. We found an expected decrease of 54.8% in the variance estimate in X5 (p = 0.029), 62.7% in AX (p = 0.033) and 50.8% in R5-19 (p = 0.019) for patients in the low A-score group compared to the high A-score. Notably, we observed no significant difference in the variance in %predicted FEV1 (%FEV1) between any A-score groups on either analysis (Table 3). We also investigated correlations in the absolute FEV1 measurements with A-score and found none (Table 3). No significant differences in either the spirometry or oscillometry metrics were identified when the zero A-score group was set as the reference (Supplementary Table 3).

We present a representative table of expected changes in spirometry and oscillometry variance with increasing categorical A-score in Supplementary Table 4. The example patient is a 58 year-old male with interstitial lung disease whose duration of ICU stay was 23.67 days and had 4 gradable transbronchial biopsies in the first year; a change from A-score zero to high results in 1.48 times increase in the variance in R5, 1.44 times in R5-19, 1.78 times in X5 and 2.10 times in AX but only 1.12 times in %FEV1.

As the A-score is a cumulative burden of graft injury, we also analyzed it as a continuous variable. Excluding patients with A-score = 0, we assessed the association of variance with an increasing burden of acute rejection. Univariable analysis identified a significant association between the A-score and the variance in X5 (Table 4; p = 0.024). The multivariable regression models, adjusted for the clinical parameters, revealed significant associations between the A-score and the variance in X5, AX, and R5-19 (p < 0.05). In other words, for a 50% increase in the A-score, there was an expected increase of 45.8%, 50% and 31.21% in the variance in X5, AX, and R5-19, respectively (Table 4). Again, we found no significant association between the variance in %FEV1 nor absolute FEV1 and the A-score (Table 4).

TABLE 4
www.frontiersin.org

Table 4. Regression analysis to evaluate association in variance in pulmonary function measures and A-score > zero.

3.2. Association of CLAD and variance in oscillometry and spirometry

As ACR is a known risk factor for CLAD (13, 16), we investigated the relationship between CLAD and variance in oscillometry among patients with ≥ 6 month follow-up. The CLAD and CLAD-free patients were similar in demographic and clinical characteristics, as well as numbers of paired oscillometry-spirometry tests and biopsies over the course of follow-up (Supplementary Tables 5, 6).

Univariable conditional logistic regression analysis showed that higher intra-subject variance in oscillometry measurements but not %FEV1 was strongly associated with a higher risk of CLAD (X5 OR: 2.19, 95% CI 1.34–3.65, p = 0.002; AX OR: 1.67, 95% CI 1.17–2.38, p = 0.005; R5-19 OR: 1.84, 95% CI 1.25–2.71, p = 0.002; Table 5).

TABLE 5
www.frontiersin.org

Table 5. Association of CLAD with A-score and variance in lung function measurements.

Multivariable analysis, adjusting for parameters known to affect graft function, showed that intra-subject variance in X5, AX, and R5-19 was independently associated with increased risk of CLAD with an OR of 2.06 (95% CI 1.22–3.49, p = 0.007), 1.57 (95% CI 1.08–2.30, p = 0.019), and 1.78 (95% CI 1.20–2.63, p = 0.004), respectively (Table 5). We found that higher variance was due to bidirectional changes rather than progressive improvement or worsening over time (Supplementary Figure 1).

4. Discussion

Monitoring with spirometry is a mainstay of post-lung transplant care with a goal of identifying early graft injury to prompt investigations for acute rejection and/or infection (27). FEV1 and forced vital capacity (FVC) are also used to determine the baseline or best lung function achieved post-transplant (24), identify baseline lung allograft dysfunction (28), and adjudicate CLAD (24). However, spirometry is known to be is poorly sensitive to graft injury (57). Based on our previous findings that oscillometry can track changes in lung mechanics associated with biopsy-proven but spirometrically silent episodes of ACR and improvement after treatment (8), we hypothesized that measurements of oscillometry parameters could provide markers of graft injury independently of spirometry.

The current study revealed that the intra-subject variance in R5-19, X5, and AX, was strongly associated with CLAD development. The positive correlations observed in the variance in X5, AX, and R5-19 with the A-score at 1 year, support the posit that variance reflects repeated episodes of patchy graft injury associated with ACR and improvement following treatment. In our previous study significant differences in AX and R5-19 were observed between the clinically significant A2 rejection and no (A0) rejection. While A1 (or minimal) rejection episodes were associated with changes in AX and R5-19 values intermediary to the A0 and A2 biopsies (8), these differences were not significant. These A1 episodes and the changes in the oscillometry measurements, however, are captured in the calculations of the variance at 1 year.

This would be in keeping with the computed tomography (CT) imaging where patchy ground-glass opacities and inhomogenous patterns of gas trapping are observed. Our findings are congruent with studies in asthma and COPD that showed variance in oscillometry measurements are predictive of future exacerbations and strongly correlated with respiratory symptoms (914, 2931). We did not find associations between R5 and the A-score or CLAD. R5 reflects total respiratory resistance and is less sensitive than the reactance measurements, particularly those of X5 and AX, to ventilatory inhomogeneity and non-linearities in the small airways (1822). The underlying pathologic processes responsible for acute rejection and CLAD, particularly early in the clinical course, occur in the small airways and lung periphery, and are likely responsible for the associations found with R5-19, X5, and AX. Future studies using quantitative imaging techniques such as hyper-polarized magnetic resonance imaging will provide a better understanding of the structure-function relationship of the different oscillometry parameters.

We recently reported that X5, AX, and R5-19 are significantly different in CLAD and time-matched CLAD-free patients at time of the initial drop in the FEV1 to 80% of baseline value (32). By definition, the diagnosis of CLAD cannot be confirmed until the FEV1 drop is sustained for 12 weeks (24). If a diagnosis could be ascertained at time of initial FEV1 drop or if oscillometry could predict CLAD earlier, it would offer a window for earlier intervention for CLAD. Further studies to evaluate the predictive value of combining variance in oscillometry along with oscillometry (32) and CT metrics at time of CLAD onset (33) are currently underway.

Our results showed no association between A-score and CLAD (Table 5). This may be due to the low power but is more likely related to the fact that the A-score is an incomplete marker of the overall burden of graft injury. It only considers biopsy-proven ACR and does not account for other causes of graft injury that contribute to CLAD, including infections, antibody-mediated rejection and aspiration. In contrast, variance in oscillometry reflects changes in respiratory mechanics associated with all types of graft injury irrespective of cause. We found no association between variance in FEV1 with the A-score, underscoring the insensitivity of spirometry for detection of acute graft rejection. As spirometry requires forced expiratory maneuvers, increases in FEV1 during the first 6–9 months (34, 35) likely result from improved physical condition of the recipient rather than improvement in lung mechanics as the graft is subjected to rejection, infection and other graft injury over time. Oscillometry is independent of patient effort. Thus, it is unsurprising that the best baseline lung function as measured by oscillometry was achieved earlier (median time ranging from 1.5 months for R5-19 and R5, and 2 months for X5 and AX) than spirometry (median 3 months for baseline FEV1).

Oscillometry offers several advantages over current monitoring modalities. Completed in < 10 min during normal quiet breathing, anyone who can breathe normally while wearing a nose clip can complete an oscillometry test. The multi-breath nitrogen washout technique is also non-invasive and has been used to evaluate small airway function following lung transplant (36), but unlike spirometry, it requires significant expertise and infrastructure. Oscillometry could be combined with other non-invasive biomarkers, such as computer-aided quantitative analysis of chest imaging (33, 37) or molecular signature of mucosal biopsies (38) to provide a cumulative risk with improved sensitivity and predictive value than individual metrics alone. Such future studies would provide value to improve in lung transplant care.

5. Limitations

This study was conducted in a single, high-volume transplant center. While this is a limitation, we were able to enroll 289 patients within 27 months. While the prospective nature of the study permitted comprehensive data collection from time of transplant, only 37 patients developed CLAD (and only 29 could be included for analysis) due to the relatively short follow-up. This is a major limitation, although the incidence of CLAD will increase over time to provide internal validation of our findings. Development of a multi-center study will provide external validation, and account for the differences in the post-transplant protocols and patient populations amongst lung transplant centers.

We excluded 22 patients who remained hospitalized at 3 months from the study (Figure 1). These patients have a complicated post-transplant course and were too sick to undergo transbronchial biopsies. As such we did not have the A-grade documentation for the A-grade calculation.

Due to the COVID-19 pandemic, our transplant center suspended surveillance bronchoscopies for stable patients between March 2020 and late 2021. For inclusion all patients in the study had completed 3 months of follow-up, a period of highest risk for acute rejection when routine post-transplant monitoring is most intense. Our data shows that the majority of clinically relevant rejections occurs early post-transplant during the initial 4 months (Supplementary Table 1). It is notable that the total number of biopsies at 1 year was different amongst the groups (Table 2). However, analysis at 100 days showed no difference with the A-score 0 and the A-score > 0 groups with each having a median of 2 bronchoscopies with gradable transbronchial biopsies (data not shown). Thus, the likelihood of rejection episodes being missed in patients who did not undergo routine surveillance biopsies at 6 to 12 months post-transplant during the pandemic or for other clinical reasons is low. Interestingly, the A-score 0 group had a longer hospital stay (Table 2). It is possible that more frequent monitoring of immunosuppressive drug levels during the additional week of hospitalization resulted enhanced immunosuppression that confers better outcomes beyond. This is a topic for future investigation.

Our study was conducted with a single oscillometry device, allowing us to compare individual patient’s values over time. Until full harmonization of the manufacturing standards commercial of oscillometers is achieved, comparisons of oscillometry measurements obtained with different oscillometers should be made with caution as discordance in the impedance measurements, particularly reactance, exist (39).

6. Conclusion

Our findings suggest that monitoring of patients with oscillometry following lung transplant provides an excellent marker of graft injury over time. Our data indicate intra-subject variance in oscillometry provides a risk assessment of subsequent CLAD, independent of other clinical variables and the A-score. It is a sound rationale to implement oscillometry as a non-invasive monitoring tool of patients following transplantation, especially at centers that do not routinely perform surveillance transbronchial biopsies. Inclusion of oscillometry as part of routine care could provide an early assessment of graft function and help identify those at higher risk for CLAD development. This will allow for earlier interventions such as changes in immunosuppressive therapies or closer monitoring, and potentially improve patient outcomes.

Data availability statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation in accordance with the institutional guidelines regarding data sharing and patient confidentiality.

Ethics statement

The studies involving human participants were reviewed and approved by the University Health Network (UHN) Research Ethics Board (REB# 17-5652). The patients/participants provided their written informed consent to participate in this study.

Author contributions

AV conducted the research, compiled and verified the clinical data, performed the data analysis, and drafted the manuscript. NH developed the statistical plan, performed and oversaw the data analysis, and drafted the manuscript. EH and JM developed the statistical analysis plan and oversaw data analysis. NB verified clinical data and edited the manuscript. JW maintained the research ethics protocol, developed the standard operating procedures and quality control of the oscillometry tests, and quality assurance of the data. TM helped with the statistical analysis plan and edited the manuscript. RG, SK, MC, JY, and TM developed and maintained the lung transplant research database and verified the clinical data. JT refined the research plan and data analysis. CR refined the research protocol, ensured quality control of pulmonary function data, and edited the manuscript. C-WC developed the concept, study protocol and oversaw all aspects of the project. All authors contributed to the article and approved the submitted version.

Funding

This study was supported by a grant-in-aid from the Lung Health Foundation, the Pettit Block Term Grants, the CIHR/NSERC Collaborative Health Research Program (grant #415013), and the Ajmera Foundation Multi-Organ Transplant Innovation Fund. AV was supported by a University of Toronto Fellowship and Queen Elizabeth II/Institute of Medical Science Graduate Scholarships in Science & Technology (QEII-GSST).

Acknowledgments

We thank the Registered Pulmonary Technologists at Toronto General Hospital for helping to conduct the study and C-WC’s research group members for collecting the oscillometry data.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fmed.2023.1158870/full#supplementary-material

Abbreviations

ACR, acute cellular rejection; AX, the area under the respiratory reactance curve; CLAD, chronic lung allograft dysfunction; CMV, cytomegalovirus; COPD, chronic obstructive pulmonary disease; ICU, intensive care unit; ISHLT, the International Society for Heart and Lung Transplantation; R5, resistance at 5 Hz; R5-19, resistance between 5 and 19 Hz; TLTP, Toronto Lung Transplant Program; UHN, University Health Network; X5, reactance at 5 Hz.

References

1. Khalifah AP, Hachem RR, Chakinala MM, Yusen RD, Aloush A, Patterson GA, et al. Minimal acute rejection after lung transplantation: a risk for bronchiolitis obliterans syndrome. Am J Transplant. (2005) 5:2022–30. doi: 10.1111/j.1600-6143.2005.00953.x

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Shino MY, Weigt SS, Li N, Derhovanessian A, Sayah DM, Huynh RH, et al. Impact of allograft injury time of onset on the development of chronic lung allograft dysfunction after lung transplantation. Am J Transplant. (2017) 17:1294–303. doi: 10.1111/ajt.14066

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Hopkins PM, Aboyoun CL, Chhajed PN, Malouf MA, Plit ML, Rainer SP, et al. Association of minimal rejection in lung transplant recipients with obliterative bronchiolitis. Am J Respir Crit Care Med. (2004) 170:1022–6. doi: 10.1164/rccm.200302-165OC

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Halloran K, Aversa M, Tinckam K, Martinu T, Binnie M, Chaparro C, et al. Comprehensive outcomes after lung retransplantation: a single-center review. Clin Transplant. (2018) 32:e13281. doi: 10.1111/ctr.13281

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Cosio M, Ghezzo H, Hogg JC, Corbin R, Loveland M, Dosman J, et al. The relations between structural changes in small airways and pulmonary-function tests. N Engl J Med. (1978) 298:1277–81. doi: 10.1056/NEJM197806082982303

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Burgel P, Bergeron A, Blic J d, Bonniaud P, Bourdin A, Chanez P, et al. Small airways diseases, excluding asthma and COPD: an overview. Eur Respir Rev. (2013) 22:131–47. doi: 10.1183/09059180.00001313

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Van Muylem A, Mélot C, Antoine M, Knoop C, Estenne M. Role of pulmonary function in the detection of allograft dysfunction after heart-lung transplantation. Thorax. (1997) 52:643–7. doi: 10.1136/thx.52.7.643

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Cho E, Wu JK, Birriel DC, Matelski J, Nadj R, DeHaas E, et al. Airway oscillometry detects spirometric-silent episodes of acute cellular rejection. Am J Respir Crit Care Med. (2020) 201:1536–44. doi: 10.1164/rccm.201908-1539OC

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Gulotta C, Suki B, Brusasco V, Pellegrino R, Gobbi A, Pedotti A, et al. Monitoring the temporal changes of respiratory resistance: a novel test for the management of asthma. Am J Respir Crit Care Med. (2012) 185:1330–1. doi: 10.1164/ajrccm.185.12.1330

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Gobbi A, Dellacá R, King G, Thamrin C. Toward predicting individual risk in asthma using daily home monitoring of resistance. Am J Respir Crit Care Med. (2017) 195:265–7. doi: 10.1164/rccm.201603-0537LE

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Gobbi A, Gulotta C, Suki B, Mellano E, Pellegrino R, Brusasco V, et al. Monitoring of respiratory resistance in the diagnosis of mild intermittent asthma. Clin Exp Allergy. (2019) 49:921–3. doi: 10.1111/cea.13376

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Kaminsky DA, Simpson SJ, Berger KI, Calverley P, Melo PL, Dandurand R, et al. Clinical significance and applications of oscillometry. Eur Respir Rev. (2022) 31:210208. doi: 10.1183/16000617.0208-2021

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Wong A, Hardaker K, Field P, Huvanandana J, King GG, Reddel H, et al. Home-based forced oscillation technique day-to-day variability in pediatric asthma. Am J Respir Crit Care Med. (2019) 199:1156–60. doi: 10.1164/rccm.201809-1659LE

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Zimmermann SC, Huvanandana J, Nguyen CD, Bertolin A, Watts JC, Gobbi A, et al. Day-to-day variability of forced oscillatory mechanics for early detection of acute exacerbations in COPD. Eur Respir J. (2020) 56:1901739. doi: 10.1183/13993003.01739-2019

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Wu JK, DeHaas E, Nadj R, Cheung AB, Dandurand RJ, Hantos Z, et al. Development of quality assurance and quality control guidelines for respiratory oscillometry in clinic studies. Respir Care. (2020) 65:1687–93. doi: 10.4187/respcare.07412

PubMed Abstract | CrossRef Full Text | Google Scholar

16. King GG, Bates J, Berger KI, Calverley P, de Melo PL, Dellacà RL, et al. Technical standards for respiratory oscillometry. Eur Respir J. (2020) 55:1900753. doi: 10.1183/13993003.00753-2019

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Graham BL, Steenbruggen I, Miller MR, Barjaktarevic IZ, Cooper BG, Hall GL, et al. Standardization of spirometry 2019 Update. An official American thoracic society and European respiratory society technical statement. Am J Respir Crit Care Med. (2019) 200:e70–88. doi: 10.1164/rccm.201908-1590ST

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Eddy R, Westcott A, Maksym G, Parraga G, Dandurand R. Oscillometry and pulmonary magnetic resonance imaging in asthma and COPD. Physiol Rep. (2019) 7:e13955. doi: 10.14814/phy2.13955

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Bates J, Irvin C, Farré R, Hantos Z. Oscillation mechanics of the respiratory system. Compr Physiol. (2011) 1:1233–72. doi: 10.1002/cphy.c100058

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Bates J, Maksym G. Mechanical determinants of airways hyperresponsiveness. Crit Rev Biomed Eng. (2011) 39:281–96. doi: 10.1615/critrevbiomedeng.v39.i4.30

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Foy BH, Soares M, Bordas R, Richardson M, Bell A, Singapuri A, et al. Lung computational models and the role of the small airways in asthma. Am J Respir Crit Care Med. (2019) 200:982–91. doi: 10.1164/rccm.201812-2322OC

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Young H, Guo F, Eddy R, Maksym G, Parraga G. Oscillometry and pulmonary MRI measurements of ventilation heterogeneity in obstructive lung disease: relationship to quality of life and disease control. J Appl Physiol. (2018) 125:73–85. doi: 10.1152/japplphysiol.01031.2017

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Todd JL, Jain R, Pavlisko EN, Copeland CA, Reynolds JM, Snyder LD, et al. Impact of forced vital capacity loss on survival after the onset of chronic lung allograft dysfunction. Am J Respir Crit Care Med. (2014) 189:159–66. doi: 10.1164/rccm.201306-1155OC

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Glanville A, Verleden G, Todd J, Benden C, Calabrese F, Gottlieb J, et al. Chronic lung allograft dysfunction: definition and update of restrictive allograft syndrome—A consensus report from the Pulmonary Council of the ISHLT. J Heart Lung Transplant. (2019) 38:483–92. doi: 10.1016/j.healun.2019.03.008

PubMed Abstract | CrossRef Full Text | Google Scholar

25. R Core Team.R: A Language and Environment for Statistical Computing. Vienna: R Foundation for Statistical Computing (2019).

Google Scholar

26. Todd JL, Neely ML, Kopetskie H, Sever ML, Kirchner J, Frankel CW, et al. Risk factors for acute rejection in the first year after lung transplant. A multicenter study. Am J Respir Crit Care Med. (2020) 202:576–85. doi: 10.1164/rccm.201910-1915OC

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Otulana B, Higenbottam T, Ferrari L, Scott J, Igboaka G, Wallwork J. The use of home spirometry in detecting acute lung rejection and infection following heart-lung transplantation. Chest. (1990) 97:353–7. doi: 10.1378/chest.97.2.353

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Liu J, Jackson K, Weinkauf J, Kapasi A, Hirji A, Meyer S, et al. Baseline lung allograft dysfunction is associated with impaired survival after double-lung transplantation. J Heart Lung Transplant. (2018) 37:895–902. doi: 10.1016/j.healun.2018.02.014

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Frantz S, Nihlén U, Dencker M, Engström G, Löfdahl C, Wollmer P. Impulse oscillometry may be of value in detecting early manifestations of COPD. Respir Med. (2012) 106:1116–23. doi: 10.1016/j.rmed.2012.04.010

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Aarli B, Calverley P, Jensen R, Eagan T, Bakke P, Hardie J. Variability of within-breath reactance in COPD patients and its association with dyspnoea [published correction appears in Eur Respir J. 2017 Jan 25;49(1):]. Eur Respir J. (2015) 45:625–34. doi: 10.1183/09031936.00051214

PubMed Abstract | CrossRef Full Text | Google Scholar

31. Dean J, Kolsum U, Hitchen P, Gupta V, Singh D. Clinical characteristics of COPD patients with tidal expiratory flow limitation. Int J Chron Obstruct Pulmon Dis. (2017) 12:1503–6. doi: 10.2147/COPD.S137865

PubMed Abstract | CrossRef Full Text | Google Scholar

32. Fu A, Vasileva A, Hanafi N, Belousova N, Wu J, Rajyam SS, et al. Characterization of chronic lung allograft dysfunction phenotypes using spectral and intrabreath oscillometry. Front Physiol. (2022) 13:980942. doi: 10.3389/fphys.2022.980942

PubMed Abstract | CrossRef Full Text | Google Scholar

33. McInnis MC, Ma J, Karur GR, Houbois C, Levy L, Havlin J, et al. Chronic lung allograft dysfunction phenotype and prognosis by machine learning CT analysis. Eur Respir J. (2021) 60:2101652. doi: 10.1183/13993003.01652-2021

PubMed Abstract | CrossRef Full Text | Google Scholar

34. Mason DP, Rajeswaran J, Murthy SC, McNeill AM, Budev MM, Mehta AC, et al. Spirometry after transplantation: how much better are two lungs than one? Ann Thorac Surg. (2008) 85:1193–201.e1–2. doi: 10.1016/j.athoracsur.2007.12.023

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Mason DP, Rajeswaran J, Li L, Murthy SC, Su JW, Pettersson GB, et al. Effect of changes in postoperative spirometry on survival after lung transplantation. J Thorac Cardiovasc Surg. (2012) 144:197–203. doi: 10.1016/j.jtcvs.2012.03.028

PubMed Abstract | CrossRef Full Text | Google Scholar

36. Thompson BR, Hodgson YM, Kotsimbos T, Liakakos P, Ellis MJ, Snell GI, et al. Bronchiolitis obliterans syndrome leads to a functional deterioration of the acinus post lung transplant. Thorax. (2014) 69:487–8. doi: 10.1136/thoraxjnl-2013-204671

PubMed Abstract | CrossRef Full Text | Google Scholar

37. Belloli EA, Degtiar I, Wang X, Yanik GA, Stuckey LJ, Verleden SE, et al. Parametric response mapping as an imaging biomarker in lung transplant recipients. Am J Respir Crit Care Med. (2017) 195:942–52. doi: 10.1164/rccm.201604-0732OC

PubMed Abstract | CrossRef Full Text | Google Scholar

38. Halloran K, Parkes MD, Timofte IL, Snell GI, Westall GP, Hachem R, et al. Molecular phenotyping of rejection-related changes in mucosal biopsies from lung transplants. Am J Transplant. (2020) 20:954–66. doi: 10.1111/ajt.15685

PubMed Abstract | CrossRef Full Text | Google Scholar

39. Dandurand R, Lavoie J, Lands L, Hantos Z. Oscillometry harmonisation study group. Comparison of oscillometry devices using active mechanical test loads. ERJ Open Res. (2019) 5:00160–2019. doi: 10.1183/23120541.00160-2019

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: oscillometry, acute rejection (AR), chronic lung allograft dysfunction (CLAD), lung transplantation (LTx), pulmonary function testing (PFT)

Citation: Vasileva A, Hanafi N, Huszti E, Matelski J, Belousova N, Wu JKY, Martinu T, Ghany R, Keshavjee S, Tikkanen J, Cypel M, Yeung JC, Ryan CM and Chow C-W (2023) Intra-subject variability in oscillometry correlates with acute rejection and CLAD post-lung transplant. Front. Med. 10:1158870. doi: 10.3389/fmed.2023.1158870

Received: 13 February 2023; Accepted: 04 May 2023;
Published: 25 May 2023.

Edited by:

Lars Knudsen, Hannover Medical School, Germany

Reviewed by:

Mark Greer, Hannover Medical School, Germany
Sarah Svenningsen, McMaster University, Canada

Copyright © 2023 Vasileva, Hanafi, Huszti, Matelski, Belousova, Wu, Martinu, Ghany, Keshavjee, Tikkanen, Cypel, Yeung, Ryan and Chow. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Chung-Wai Chow, Y2h1bmctd2FpLmNob3dAdWhuLmNh

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.