Skip to main content

REVIEW article

Front. Med., 13 March 2023
Sec. Ophthalmology
This article is part of the Research Topic Reviews in: Ophthalmology 2023 View all 12 articles

Evaluation of corneal dendritic cell density and subbasal nerve density in contact lens wearers using IVCM: A systematic review and meta-analysis

\r\nRongjie Guo&#x;Rongjie GuoJiaxuan Jiang&#x;Jiaxuan JiangYanan Zhang&#x;Yanan ZhangQi LiangQi LiangTaige ChenTaige ChenKai Hu*Kai Hu*
  • Department of Ophthalmology, The Affiliated Drum Tower Hospital, Medical School of Nanjing University, Nanjing, China

Purpose: To evaluate the subclinical changes in corneal dendritic cell density (CDCD) and corneal subbasal nerve density (CSND) in asymptomatic contact lens (CL) wearers.

Methods: Databases including PubMed, Scopus, Web of Science, and Cochrane Central Register of Controlled Trials were searched for trials and studies reporting the changes of corneal CDCD and CSND in contact lens wearers published until 25 June 2022. PRISMA guidelines as well as recommended meta-analysis practices were followed. Meta-analysis was conducted using RevMan V.5.3 software.

Results: After the screening, 10 studies with 587 eyes of 459 participants were included. Seven studies reported the data of CDCD. Compared with the control group, CDCD in the CL wearers was higher (18.19, 95% CI 18.8–27.57, p = 0.0001). Type of in vivo confocal microscopy (IVCM), wear duration, and frequency of lens change were sources of heterogeneity. The difference in CSND between CL wearers and the control group was insignificant, and subgroup analysis did not reveal a source of heterogeneity.

Conclusion: Overall, CDCD increased in CL wears, while CSND did not show significant differences. IVCM is a feasible tool to assess subclinical changes in CL wearers.

Introduction

Contact lenses (CL) are an essential part of vision care worldwide. It is commonly used to correct refraction and slow the progression of myopia. However, up to 75% of CL wearers reported eye discomfort, which can lead to CL intolerance (1, 2). A significant number of CL wearers are clinically diagnosed with dry eye disease (DED) (2). Asymptomatic contact lens wearers refer to CL wearers who have not been clinically diagnosed with CL-related diseases such as DED and who have no subjective discomfort. Subclinical changes in asymptomatic contact lens wearers still require attention. Previous studies have demonstrated that wearing contact lenses leads to changes in the corneal nerves and increase in infiltrating immune cells (3, 4). The alteration in the corneal nerves is responsible for the symptom of eye discomfort (5), and the increased immune cells reflect rising levels of inflammation on the ocular surface (6). Changes in the corneal nerves and inflammation levels are core factors in the pathogenesis of DED and mediate the development of CL-related DED (7). Thus, the subclinical corneal changes of CL wearers and their relation to CL discomfort requires in-depth investigation.

As a non-invasive method, in vivo confocal microscopy (IVCM) has become increasingly important in diagnosing ocular and systemic diseases. Due to its ease of operation and 800× magnification of living cell structures, IVCM allows clinicians to observe the eye at the cellular level under in vivo conditions (8). In recent years, studies using IVCM have focused on assessing the cornea’s neuronal changes and inflammatory states. Studies in multiple diseases have demonstrated the alteration in the corneal nerves and increased immune cells, such as keratitis (9) and corneal dystrophies (10).

Although several studies have investigated the effects of CL on the ocular surface using IVCM, divergent results were yielded. Multiple clinical trials have examined the effects of CL wearing on the corneal nerve density; however, the field has yet to reach a consensus. Therefore, we conducted a meta-analysis of clinical trials to evaluate the effects of CL on the cornea, including corneal subbasal nerve density (CSND) and corneal dendritic cell density (CDCD).

Methods

Search methods

The following databases were searched for studies published up to 25 June 2022: Pubmed, Scopus, Web of Science, and Cochrane Central Register of Controlled Trials, using these search strategies (Contact Lens OR Lens, Contact OR Lenses, Contact) and (in vivo confocal microscopy OR confocal microscopy OR IVCM).

Eligibility criteria for considering studies

Articles were included if they reported corneal dendritic cell density (CDCD) and corneal sub-basal nerve density (CSND) detected by in vivo confocal microscopy (IVCM). Exclusion Criteria were as follows: (1) subjects included minors; (2) inappropriate article type: such as reviews, case reports, conference papers, editorials, short surveys, or letters; (3) published not in English; (4) studies only contained cells and animal experiments; (5) subjects with systemic or ocular diseases or surgery history.

Data collection

Search results from all electronic databases were exported to Endnote X9 reference management software for screening. The titles and abstracts of the articles were independently evaluated by two reviewers (RG and JJ). In cases of disagreements, full texts of articles were screened, and ambiguity was solved by discussion or consulting a third reviewer (KH). Data from included studies were extracted by a single reviewer (RG) in Microsoft Excel and checked by a second reviewer (JJ). Extracted information includes: the first author of the article, year of publication, country of the first author, journal of publication, number of patients, sample size (eyes), age of patients, gender of patients, type of IVCM systems, CL type, CL wearing duration, the mean and standard deviation of CDCD, and CSND.

Risk of bias assessment

The studies included in this research consisted of case-control studies and cross-sectional studies. The 11-item checklist recommended by the Agency for Healthcare Research and Quality was used to assess the risk of bias in cross-sectional studies. Each study was judged as follows: low quality = 0-3, moderate quality = 4-7, and high quality = 8-11. The risk of bias in case-control studies was assessed by the Newcastle-Ottawa Scale. Article quality was judged as low quality = 0–5 stars, medium quality = 6-7 stars, and high quality = 8–9 stars.

Data synthesis and analysis

We used Review Manager Software 5.3® for statistical analysis. The data were analyzed by using the mean difference. We calculated the weighted mean difference (WMD) and associated 95% confidence interval (CI) for CDCD and CSND. Pooled estimates of effects were calculated by using random effects models. Heterogeneity was quantified by the I2 statistic; I2 > 50% defined high heterogeneity between studies. Subgroup analyses were performed when I2 > 50% to compare the heterogeneity as follows: country of study, type of IVCM, type of contact lens, CL wearing duration, and whether a daily change of CL.

Results

Search results

After a systematic literature search, 2,121 references were identified, and 10 randomized clinical trials that met the inclusion criteria were included (Figure 1). The included studies consist of 2 case-control studies (11, 12) and 8 cross-sectional studies (5, 1319). A total of 459 patients with 587 eyes were included. Details about the included studies are shown in Table 1.

FIGURE 1
www.frontiersin.org

Figure 1. Flow diagram of the studies selection process.

TABLE 1
www.frontiersin.org

Table 1. Characteristics of the included studies.

Quality assessment

One trial was considered to have an overall high risk of bias. Nine studies were of moderate quality, although some uncertain risk of bias remained. Subgroup analysis for the outcome comparing low versus moderate quality trials was performed. More details are shown in Table 2.

TABLE 2
www.frontiersin.org

Table 2. Subgroup meta-analysis of CSND.

Corneal dendritic cell density

Seven studies were included in this analysis. CDCD was significantly higher in CL wearers than in controls, with an overall RR of 18.19 (95% CI 18.8–27.57, p = 0.0001), which supports the inflammatory ocular environment of CL wearers. The included studies showed high heterogeneity (I2 = 72%). The detailed results can be found in Figure 2. The subgroup analysis of the country and the type of contact lens also showed high heterogeneity. In the subgroup analysis of the type of IVCM, the HRTIII/RCM subgroup showed lower heterogeneity (I2 = 53%, p = 0.1). In the comparison grouped by wearing duration, the subgroups with a wearing duration of ≤3 months and >3 months both showed very low heterogeneity (I2 = 25%, p = 0.26 vs. I2 = 0%, p = 0.55). CL wearing time of more than 3 months significantly upregulated CDCD (RR 32.68, 95% CI 21.22–44.13, p < 0.0001). Daily contact lens replacement was also a source of heterogeneity. Both the daily disposable CL (I2 = 41%, p = 0.18) and daily reusable CL (I2 = 48%, p = 0.15) subgroups showed low heterogeneity. The daily disposable CL group (RR 32.68, 95% CI 21.22–44.13, p < 0.0001) showed a higher CDCD than the daily reusable CL group (RR 32.68, 95% CI 21.22–44.13, p < 0.0001). Further details are provided in Table 3.

FIGURE 2
www.frontiersin.org

Figure 2. Forest plot of CDCD in CL wearer vs. control group. CI, confidence interval; IV, inverse variance; SD, standard deviation; CLW, contact lens wearers; CDCD, corneal dendritic cell density.

TABLE 3
www.frontiersin.org

Table 3. Subgroup meta-analysis of CDCD.

Corneal subbasal nerve density

Five studies were included, and no significant difference was observed when assessing the change in CSND (p = 0.09), with an overall RR of −2.86 (95% CI -6.18–0.46). Wearing contact lenses did not significantly change CSND in the wearers compared to the controls. Included studies show high heterogeneity (I2 = 83%), and subgroup analysis did not reveal a source of heterogeneity. The details are shown in Figure 3 and Table 2.

FIGURE 3
www.frontiersin.org

Figure 3. Forest plot of CSND in CL wearer vs. control group. CI, confidence interval; IV, inverse variance; SD, standard deviation; CLW, contact lens wearers; CSND, corneal sub-basal nerve density.

Discussion

As a highly prevalent treatment method, CL are receiving increasing attention. Although a significant number of CL wearers are diagnosed with DED, subclinical changes in the corneas of the wearers who are not clinically diagnosed remain of concern. When searching electronic databases, we found that several relevant studies had included subjects diagnosed with DED. This study focuses on the subclinical changes in healthy CL wearers. Thus, only studies investigating asymptomatic healthy CL wearers were selected. Ten articles were included in this study after screening. We analyzed CDCD, CSND, and assessed the effects of quality of the literature, country of study, type of IVCM, type of CL, wearing duration, and daily change on the outcomes.

Dendritic cells (DCs) are considered the most important resident corneal antigen-presenting cells (20). It has been demonstrated that corneal DCs are involved in multiple ocular surface diseases (21). The proliferation and maturation of DCs represent an inflammatory state of the ocular surface (22). Due to its real-time and non-invasive features, HRT/RCM of IVCM allows real-time observation of the corneal DCs from the cellular level.

Consistent with previous clinical findings, our overall results show a significant increase in CDCD in CL wearers (p = 0.0001). Our analysis demonstrated that even in asymptomatic healthy CL wearers, the cornea exhibited subclinical inflammation status. The changes, which were presented in asymptomatic healthy wearers, indicated that the inflammatory state was caused by CL, not CL-associated ocular surface diseases such as DED. Furthermore, we hypothesized that CL-induced subclinical inflammation was involved in the pathogenesis of DED in CL wearers. In subgroup analysis, the HRTIII/RCM subgroup showed lower heterogeneity compared to HRT/RCM and HRTII/RCM subgroups, suggesting that the results of studies using HRTIII/RCM for CDCD assessment are more stable and comparable.

The changes in the cornea have been associated with CL wear duration. A recent study showed that the density of corneal DCs significantly increased 1 week after soft CL wear, peaked at 1 month, and decreased after 3 months of CL wear (23). In our study, the duration of CL wear in the included studies ranged from 8 h to 14 years. We set 3 months as the boundary to divide the duration of wear into more than or less than 3 months. Unlike previous studies, we found that CL wearing for more than 3 months resulted in upregulated corneal DCs density compared with CL wearing for less than 3 months, and there were significant differences between the two groups. This study included different materials and types of contact lenses, and a comparison of wear duration for a particular type of CL may be more relevant.

It was generally considered that daily reusable contact lenses had a more significant impact on the cornea and carried a greater risk of disease than daily disposable lenses (24). However, our analysis demonstrated the opposite results. The CDCD of the daily disposable CL group was higher than the daily reusable CL group. Nonetheless, only 6 articles were included in this subgroup analysis, and more research may be needed to confirm this conclusion.

It has been demonstrated by IVCM and animal experiments that the density of DCs in the central cornea is lower than in the peripheral cornea (20). Five of the seven studies included did not clarify whether the DCs were in the central or peripheral cornea. Based on the analysis of their reported amounts, we speculated that these results may be from the peripheral cornea, and contacted the authors for confirmation. In two other studies, both central and peripheral cornea data were reported. To maintain data consistency, we only selected peripheral corneal data from these two studies for analysis.

The effects of CL wear on corneal nerves have been controversial. A few studies using IVCM have shown that wearing CL does not affect corneal nerve density, morphology, and distribution (8). Patel et al. (25) reported no reduction in corneal nerve density after CL wear, but corneal sensitivity decreased in CL wearers compared with the controls. Some studies presented conflicting results. Lum et al. (3) demonstrated by IVCM that CL wear resulted in decreased central corneal nerve density. Hiraoka et al. (26) reported that overnight orthokeratology lens wearing down-regulated corneal nerve density. Herein, we included five studies for the analysis of corneal nerve density. Two of these five studies reported a reduction in corneal nerve density, and the other three showed no significant changes. Our results showed that CL wear did not significantly alter the corneal nerve density. Although the results had no statistical significance, the CL group still showed lower corneal nerve density.

Subgroup analysis of the corneal nerve density was also performed, but the results did not reveal the source of heterogeneity and the differences between subgroups. This may be due to the small number of studies included. In addition to corneal nerve density, some studies have also investigated nerve fiber tortuosity, nerve fiber interconnections, the density of nerve branches, and nerve reflectivity. However, fewer than three studies reported these data. Therefore, the data were not further analyzed.

Our results showed that wearing CL did not directly lead to changes in the corneal nerves. Some studies have reported that CL wear reduced corneal sensitivity (27, 28). The decrease in corneal sensitivity has been attributed to disrupted corneal metabolism, mechanical effects, and sensory adaptations (29) caused by CL. In addition, CL wear can lead to the development of dry eye disease, further contributing to corneal nerve changes associated with the disease.

Our study has the following limitations: First, the number of articles included in this study was limited. If more new articles that meet the inclusion criteria can be included, more convincing outcomes might be drawn. Second, despite the attempt to control potential sources of heterogeneity, there were differences in study design, patient populations, and IVCM measurements that could have influenced outcomes. Meta-analysis that contains more studies with less heterogeneity may avoid the effect of heterogeneity on the results.

In conclusion, CL wear was associated with an increase in CDCD. When evaluating CDCD with IVCM, the results were more stable with HRTIII/RCM. CDCD was also related to CL wear duration and whether the lenses were changed daily. Although wearing contact lenses slightly reduced CSND, it was not statically significant. IVCM appears to be a feasible tool to assess subclinical changes in CL wearers.

Author contributions

RG and KH conceived and designed the overall study. RG, JJ, YZ, and KH worked on data acquisition. RG and QL worked on data analysis and interpretation. RG and TC prepared the original manuscript. KH supervised and reviewed the manuscript. All authors read and approved the final version of the manuscript.

Funding

This study was supported by the National Natural Science Foundation of China (81870695), Natural Science Foundation of Jiangsu Province (SBK2020022490), Key Program of Nanjing Science and Technology Development Plan (ZKX20022), Nanjing Science and Technology Development Plan (YKK21095), and Clinical Trials from the Affiliated Drum Tower Hospital, Medical School of Nanjing University.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Vajdic C, Holden B, Sweeney D, Cornish R. The frequency of ocular symptoms during spectacle and daily soft and rigid contact lens wear. Optom Vis Sci. (1999) 76:705–11. doi: 10.1097/00006324-199910000-00022

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Begley C, Caffery B, Nichols K, Chalmers R. Responses of contact lens wearers to a dry eye survey. Optom Vis Sci. (2000) 77:40–6.

Google Scholar

3. Lum E, Golebiowski B, Swarbrick H. Mapping the corneal sub-basal nerve plexus in orthokeratology lens wear using in vivo laser scanning confocal microscopy. Invest Ophthalmol Vis Sci. (2012) 53:1803–9. doi: 10.1167/iovs.11-8706

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Zhivov A, Stave J, Vollmar B, Guthoff R. In vivo confocal microscopic evaluation of Langerhans cell density and distribution in the normal human corneal epithelium. Graefes Arch Clin Exp Ophthalmol. (2005) 243:1056–61. doi: 10.1007/s00417-004-1075-8

PubMed Abstract | CrossRef Full Text | Google Scholar

5. López-De La Rosa A, Arroyo-Del Arroyo C, Cañadas P, López-Miguel A, Calonge M, Enríquez-De-Salamanca A, et al. Are contact lens discomfort or soft contact lens material properties associated with alterations in the corneal sub-basal nerve plexus? Curr Eye Res. (2018) 43:487–92. doi: 10.1080/02713683.2017.1420804

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Cavalcanti B, Cruzat A, Sahin A, Pavan-Langston D, Samayoa E, Hamrah P. In vivo confocal microscopy detects bilateral changes of corneal immune cells and nerves in unilateral herpes zoster ophthalmicus. Ocul Surf. (2018) 16:101–11. doi: 10.1016/j.jtos.2017.09.004

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Calonge M, Enríquez-de-Salamanca A, Diebold Y, González-García M, Reinoso R, Herreras J, et al. Dry eye disease as an inflammatory disorder. Ocul Immunol Inflamm. (2010) 18:244–53. doi: 10.3109/09273941003721926

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Cruzat A, Qazi Y, Hamrah P. In Vivo confocal microscopy of corneal nerves in health and disease. Ocul Surf. (2017) 15:15–47. doi: 10.1016/j.jtos.2016.09.004

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Hamrah P, Cruzat A, Dastjerdi M, Zheng L, Shahatit B, Bayhan H, et al. Corneal sensation and subbasal nerve alterations in patients with herpes simplex keratitis: An in vivo confocal microscopy study. Ophthalmology. (2010) 117:1930–6. doi: 10.1016/j.ophtha.2010.07.010

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Mocan M, Yilmaz P, Irkec M, Orhan M. In vivo confocal microscopy for the evaluation of corneal microstructure in keratoconus. Curr Eye Res. (2008) 33:933–9. doi: 10.1080/02713680802439219

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Alzahrani Y, Pritchard N, Efron N. Changes in corneal Langerhans cell density during the first few hours of contact lens wear. Cont Lens Anterior Eye. (2016) 39:307–10. doi: 10.1016/j.clae.2016.02.008

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Tse V, Zhou Y, Truong T, Lin K, Tan B, Lin M. Corneal health during three months of scleral lens wear. Optom Vis Sci. (2020) 97:676–82. doi: 10.1097/OPX.0000000000001566

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Dogan A, Gurdal C, Arslan N. Corneal confocal microscopy and dry eye findings in contact lens discomfort patients. Cont Lens Anterior Eye. (2018) 41:101–4. doi: 10.1016/j.clae.2017.08.001

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Golebiowski B, Chao C, Stapleton F, Jalbert I. Corneal nerve morphology, sensitivity, and tear neuropeptides in contact lens wear. Optom Vis Sci. (2017) 94:534–42. doi: 10.1097/OPX.0000000000001063

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Hu L, Chen J, Zhang L, Sun X, Huang J, Xie W, et al. Effects of Long-term Soft Contact Lenses on Tear Menisci and Corneal Nerve Density. Eye Contact Lens. (2016) 42:196–201. doi: 10.1097/ICL.0000000000000177

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Lum E, Golebiowski B, Swarbrick H. Reduced corneal sensitivity and sub-basal nerve density in long-term orthokeratology lens wear. Eye Contact Lens. (2017) 43:218–24. doi: 10.1097/ICL.0000000000000285

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Nombela-Palomo M, Felipe-Marquez G, Hernandez-Verdejo J, Nieto-Bona A. Short-term effects of overnight orthokeratology on corneal sub-basal nerve plexus morphology and corneal sensitivity. Eye Contact Lens. (2018) 44:77–84. doi: 10.1097/ICL.0000000000000282

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Sindt C, Grout T, Critser D, Kern J, Meadows D. Dendritic immune cell densities in the central cornea associated with soft contact lens types and lens care solution types: A pilot study. Clin Ophthalmol. (2012) 6:511–9. doi: 10.2147/OPTH.S28083

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Saliman N, Morgan P, MacDonald A, Maldonado-Codina C. Subclinical inflammation of the ocular surface in soft contact lens wear. Cornea. (2020) 39:146–54. doi: 10.1097/ICO.0000000000002192

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Hamrah P, Liu Y, Zhang Q, Dana M. The corneal stroma is endowed with a significant number of resident dendritic cells. Invest Ophthalmol Vis Sci. (2003) 44:581–9.

Google Scholar

21. Hu K, Harris D, Yamaguchi T, von Andrian U, Hamrah P. A dual role for corneal dendritic cells in herpes simplex keratitis: Local suppression of corneal damage and promotion of systemic viral dissemination. PLoS One. (2015) 10:e0137123. doi: 10.1371/journal.pone.0137123

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Hao R, Ding Y, Li X. Alterations in corneal epithelial dendritic cell in Sjogren’s syndrome dry eye and clinical correlations. Sci Rep. (2022) 12:11167. doi: 10.1038/s41598-022-15537-4

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Xu Y, Xu Z, Shu X, Liu Q, Wang Y, Xia J, et al. Dynamic changes of ocular surface in first-time contact lens wearers and the effective factors of contact lens discomfort. Front Med. (2022) 9:833962. doi: 10.3389/fmed.2022.833962

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Carnt N, Minassian D, Dart J. Acanthamoeba keratitis risk factors for daily wear contact lens users: A case-control study. Ophthalmology. (2023) 130:48–55. doi: 10.1016/j.ophtha.2022.08.002

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Patel S, McLaren J, Hodge D, Bourne W. Confocal microscopy in vivo in corneas of long-term contact lens wearers. Invest Ophthalmol Vis Sci. (2002) 43:995–1003.

Google Scholar

26. Hiraoka T, Kaji Y, Okamoto F, Oshika T. Corneal sensation after overnight orthokeratology. Cornea. (2009) 28:891–5. doi: 10.1097/ICO.0b013e31819c4fb1

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Polse K. Etiology of corneal sensitivity changes accompanying contact lens wear. Invest Ophthalmol Vis Sci. (1978) 17:1202–6.

Google Scholar

28. Stapleton F, Tan M, Papas E, Ehrmann K, Golebiowski B, Vega J, et al. Corneal and conjunctival sensitivity to air stimuli. Br J Ophthalmol. (2004) 88:1547–51.

Google Scholar

29. Stapleton F, Marfurt C, Golebiowski B, Rosenblatt M, Bereiter D, Begley C, et al. The TFOS international workshop on contact lens discomfort: Report of the subcommittee on neurobiology. Invest Ophthalmol Vis Sci. (2013) 54:TFOS71–97. doi: 10.1167/iovs.13-13226

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: contact lens (CL), IVCM, dendritic cells, nerve, corneal

Citation: Guo R, Jiang J, Zhang Y, Liang Q, Chen T and Hu K (2023) Evaluation of corneal dendritic cell density and subbasal nerve density in contact lens wearers using IVCM: A systematic review and meta-analysis. Front. Med. 10:1149803. doi: 10.3389/fmed.2023.1149803

Received: 23 January 2023; Accepted: 27 February 2023;
Published: 13 March 2023.

Edited by:

Michele Lanza, The University of Campania Luigi Vanvitelli, Italy

Reviewed by:

Stefano Barabino, University of Milan, Italy
Weihua Yang, Jinan University, China

Copyright © 2023 Guo, Jiang, Zhang, Liang, Chen and Hu. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Kai Hu, S2FpX2h1QG5qdS5lZHUuY24=

These authors have contributed equally to this work and share first authorship

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.