Skip to main content

SYSTEMATIC REVIEW article

Front. Med., 26 May 2023
Sec. Gastroenterology

Comparison of oral sodium phosphate tablets and polyethylene glycol lavage solution for colonoscopy preparation: a systematic review and meta-analysis of randomized clinical trials

\r\nLi Yao-dong,
Li Yao-dong1,2*Wang Yi-pingWang Yi-ping3Mai GangMai Gang4Han Yang-yunHan Yang-yun4Zhu Ling-ling&#x;Zhu Ling-ling3Deng HongDeng Hong1Deng Jia-zhengDeng Jia-zheng1Xiang Rong-chaoXiang Rong-chao4Li You-weiLi You-wei4Zhao MingZhao Ming1Ding Shun-binDing Shun-bin1Ling JingLing Jing1Shen YangShen Yang1Dong Jia-qiDong Jia-qi1Deng LeiDeng Lei1Song Xiong-fengSong Xiong-feng1Zhang You-jianZhang You-jian1Zhou Zuo-qiong&#x;Zhou Zuo-qiong2
  • 1Gastroenterology Department of Deyang People's Hospital, Deyang, China
  • 2School of Medical and Life Sciences, Chengdu University of Traditional Chinese Medicine, Chengdu, China
  • 3West China Hospital, Sichuan University, Chengdu, China
  • 4Surgical Department of Deyang People's Hospital, Deyang, China

Objective: To systematically compare the bowel cleaning ability, patient tolerance and safety of oral sodium phosphate tablets (NaPTab) and oral polyethylene glycol electrolyte lavage solution (PEGL) to inform clinical decision making.

Methods: PubMed, Embase, CBM, WanFang Data, CNKI, and VIP databases were searched for studies that used randomized controlled trials (RCTs) to compare the roles of NaPTab and PEGL in bowel preparation before colonoscopy. Two reviewers independently screened the studies, extracted data, and assessed the risk of bias in the included papers. A meta-analysis was performed using RevMan 5.3 software.

Results: A total of 13 RCTs were eligible for inclusion, including 2,773 patients (1,378 and 1,395 cases in the NaPTab and PEGL groups, respectively). Meta-analysis revealed no significant difference in the cleansing quality of the NaPTab and PEGL groups [RR 1.02, 95% CI (0.96–1.08), P = 0.46]. The incidence of nausea was lower in the NaPTab group than in the PEGL group [RR 0.67, 95% CI (0.58–0.76), p < 0.00001]. Patients rated the taste of NaPTab higher than PEGL [RR 1.33, 95% CI (1.26–1.40), P < 0.00001]. Willingness to repeat the treatment was also higher in the NaPTab group than in the PEGL group [RR 1.52, 95% CI (1.28–1.80), P < 0.00001]. Both serum potassium and serum calcium decreased in both groups after the preparation; however, meta-analysis revealed that both minerals decreased more in the NaPTab group than in the PEGL group [MD = 0.38, 95% CI (0.13–0.62), P = 0.006 for serum potassium and MD = 0.41, 95% CI (0.04–0.77), P = 0.03 for serum calcium]. Meanwhile, serum phosphorus increased in both groups after the preparation; however, levels increased more in the NaPTab group than in the PEGL group [MD 4.51, (95% CI 2.9–6.11), P < 0.00001].

Conclusions: While NaP tablets and PEGL were shown to have a similar cleaning effect before colonoscopy, NaP tablets had improved patient tolerance. However, NaP tablets had a strong effect on serum potassium, calcium, and phosphorus levels. For patients with low potassium, low calcium, and renal insufficiency, NaP tablets should be prescribed with caution. For those at high-risk for acute phosphate nephropathy, NaP tablets should be avoided. Given the low number and quality of included studies, these conclusions will require additional verification by large high-quality studies.

Systematic review registration: 10.37766/inplasy2023.5.0013, identifier: NPLASY202350013.

1. Introduction

Ideal bowel preparation allows for a detailed examination of the entire colon and should be safe and acceptable to patients. Insufficient bowel preparation is a cause of incomplete colonoscopy. Polyethylene glycol electrolyte lavage solution (PEGL), for example, is associated with inadequate cleaning rates of ≥10% (1, 2). Insufficient bowel preparation before colonoscopy can prevent the cecum from being reached or even approached and cause the mucous membranes to appear unclear (3). There is no ideal preparation that is safe, convenient, tolerable, and inexpensive (4). Oral sodium phosphate (OSP) and PEGL are the main methods for bowel preparation (5). PEGL has been available since 1980 and its efficacy was established compared with older diet and cathartic regimens (6). PEGL are large-volume (2–4 L), osmotically-balanced non-absorbable solutions that act as purgatives to evacuate the intestine. Similarly, 2 L PEG/bisacodyl preparations are as effective as the standard 4 L PEG regimens but are better tolerated (7). OSP acts as an osmotic purgative, drawing water into the bowel lumen and stimulating peristalsis and evacuation and OSP solution is a low volume laxative (8).

Oral sodium phosphate tablets (NaPTab) are convenient and associated with a lower incidence and severity of nausea than OSP solution (9). The current study conducted a meta-analysis of reports conducted to compare the use of NaPTab and PEGL for colonoscopy preparation. Differences in bowel cleaning effect, patient tolerance and safety were assessed to inform strategies for clinical use of the two treatments.

2. Materials and methods

2.1. Registration and search strategy

2.1.1. Registration

The registration number of the systematic review protocol was INPLASY202350013 in the INPLASY.

2.1.2. Search strategy

Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used to conduct this meta-analysis (10). A systematic search was performed of several databases, including PubMed, China National Knowledge Infrastructure (CNKI), Chinese Science and Technology Journals Database (VIP), Chinese Biomedical Literature Database (CBM), Wanfang Database, and Embase. The search was conducted using the following keywords: colonoscopy, bowel preparation, bowel cleaning, sodium phosphate, sodium phosphate tablets, polyethylene glycol electrolyte lavage solution, and polyethylene glycol. The retrieval strategy is shown in Box 1 using PubMed as an example.

Box 1. PubMed retrieval strategy.

#1 colonoscopy

#2 bowel preparation OR bowel cleaning

#3 sodium phosphate OR sodium phosphate tablets

#4 polyethylene glycol electrolyte lavage solution OR polyethylene glycol

#5 #1 AND #2 AND #3 AND #4

2.2. Inclusion criteria

The inclusion criteria included (1) patient populations with an indication for colonoscopy, including outpatients or inpatients requiring diagnosis or treatment (those receiving a sigmoidoscopy were not considered), (2) randomized controlled trial (RCT) study designs, (3) a sodium phosphate tablet intervention group, (4) a control group receiving PEGL administered orally or by nasogastric tube, (5) outcome measures including cleansing quality, adverse effects (incidence of nausea), patient acceptance (taste and willingness to repeat the treatment), and changes in serum electrolytes after preparation, and (6) all included articles were available in English.

2.3. Exclusion criteria

The exclusion criteria included (1) articles that were not rigorous or had incomplete data, (2) trials of bowel preparation treatments other than NaPTab and PEGL, (3) repeated publication of the same study, and 4)not in the English language.

2.4. Data extraction and quality assessment

Two reviewers (Li Yao-dong and Zhou Zuo-qiong) independently screened the literature, extracted data and cross-checked studies that met both the inclusion and exclusion criteria. Differences were solved by discussion or consultation with a third reviewer (Zhu Ling-ling et al.). The researchers began by reading the titles of the articles and excluding any studies that were obviously irrelevant before reading the abstract or full text of remaining articles to determine whether or not they should be included. Extracted data primarily included: basic report information (including title, author, publication date), methodology (including sample size, baseline characteristics, interventions), outcome evaluation indicators (including adverse drug events and adverse drug reactions) and key elements associated with a risk of bias.

Quality assessment was performed using the Cochrane risk-of-bias tool, which consists of a random distribution method, a distribution hiding method, a blind method, incomplete results and other deviations. Each study was rated as “yes” (low risk of bias), “no” (high risk of bias) or “unclear” (uncertain risk of bias) (11).

2.5. Statistical analysis

Meta-analysis was conducted using RevMan5.3 software. Quantitative data were presented as the relative risk degree (RR) and 95% confidence interval (CI). Measurement data included the mean difference (MD) and 95% CI as the effect index. The chi-square and I-square tests were used to measure heterogeneity in the trials (the test level was α = 0.05). If there was no obvious heterogeneity (p > 0.10, I2 < 50%) then the fixed effect model was used for analysis. When p < 0.10 and I2 ≥ 50%, a random effect model was used for analysis. Sensitivity analysis were used to handle obvious clinical heterogeneity. Publication bias was assessed through the visual check of funnel plots.

3. Results

3.1. Study selection process

Using the specified search strategy, 286 references were initially retrieved. After removing duplicate articles, 153 articles remained. Of these, 13 met both the inclusion and exclusion criteria, and were included in the meta-analysis (9, 1223). The screening process is shown in Figure 1.

FIGURE 1
www.frontiersin.org

Figure 1. Flowchart of the literature search and selection process.

3.2. Characteristics of included studies

All 13 RCTs were conducted outside of China and were published in English. The basic characteristics of the RCTs are listed in Table 1.

TABLE 1
www.frontiersin.org

Table 1. Basic characteristics of the included studies.

3.3. Quality evaluation of included studies

The quality of the 13 RCTs is shown in Figure 2. All articles mentioned using a “random” design but only ten described the specific randomization method used. Only two of 13 trials described the allocation plan. All trials used a blinded method to evaluate research objects and outcomes, had complete outcome data and did not describe other potential biases.

FIGURE 2
www.frontiersin.org

Figure 2. Quality evaluation of included studies.

3.4. Results of meta-analysis

3.4.1. Adequate cleansing quality

Eight trials including 2,605 patients used adequate cleansing quality as an index of bowel cleaning quality (the rate of excellent and good) (9, 12, 13, 18, 19, 2123). Heterogeneity testing revealed significant heterogeneity among the RCTs (P = 0.002), so the random effect model was used for analysis. Meta-analysis results showed that the ratio of excellent and good bowel cleaning quality was similar between the NaPTab and PEGL groups [RR 1.02, 95% CI (0.96–1.08), P = 0.46] (Figure 3).

FIGURE 3
www.frontiersin.org

Figure 3. Rate of excellent and good bowel cleaning quality.

Subgroup analysis according to different volumes of PEGL was conducted, 2 L PEGL subgroup and 4 L PEGL subgroup. Heterogeneity testing revealed significant heterogeneity among each subgroup, so the random effect model was used for analysis. Meta-analysis results showed that in each subgroup the ratio of excellent and good bowel cleaning quality was similar between the NaPTab and PEGL groups [P = 0.93, P = 0.49 accordingly] (Figure 4).

FIGURE 4
www.frontiersin.org

Figure 4. Subgroup analysis according different volumes of PEGL.

Subgroup analysis according to different numbers of sodium phosphate tablets was conducted, 32 or less subgroup and more than 32 subgroup. Heterogeneity testing revealed significant heterogeneity among 32 or less subgroup, so the random effect model was used for analysis. Meta-analysis results showed that in 32 or less subgroup the ratio of excellent and good bowel cleaning quality was similar between the NaPTab and PEGL groups [P = 0.89]. However, heterogeneity testing revealed no significant heterogeneity among more than 32 subgroup, so the fixed effect model was used for analysis. Meta-analysis results showed that in more than 32 subgroup the ratio of excellent and good bowel cleaning quality of the NaPTab group was higher than the PEGL group [RR 1.09, 95% CI (1.03, 1.16), p = 0.003] (Figure 5).

FIGURE 5
www.frontiersin.org

Figure 5. Rate of excellent and good bowel cleaning quality.

3.4.2. Nausea

Four trials including 1,531 patients used nausea incidence as an indicator of side effects (15, 17, 20, 23). Heterogeneity testing showed no significant heterogeneity among the RCTs (P = 0.26) so the fixed effect model was used for analysis. Meta-analysis results showed that nausea incidence was lower in the NaPTab group than in the PEGL group [RR 0.67, 95% CI (0.58–0.76), p < 0.00001] (Figure 6).

FIGURE 6
www.frontiersin.org

Figure 6. Incidence of nausea.

3.4.3. Taste evaluation

Four trials including 1,530 patients used the rate of excellent and good taste to compare the two preparations (15, 17, 19, 22). Heterogeneity testing showed no significant heterogeneity among the RCTs (P = 0.61), so the fixed effect model was employed for analysis. Meta-analysis results showed that the taste rating of the NaPTab group was higher than the PEGL group [RR 1.33, 95% CI (1.26, 1.40), p < 0.00001] (Figure 7).

FIGURE 7
www.frontiersin.org

Figure 7. Rate of excellent and good taste.

3.4.4. Willingness to repeat treatment

Four articles including 1,401 patients assessed willingness to receive the same bowel preparation method (15, 16, 20, 21). Heterogeneity testing showed that there was significant heterogeneity among the RCTs (P = 0.001), so the random effect model was used for analysis. Meta-analysis results showed that the NaPTab group had a higher willingness to repeat the treatment than the PEGL group [RR 1.52, 95% CI (1.28–1.80), P < 0.00001] (Figure 8).

FIGURE 8
www.frontiersin.org

Figure 8. Willingness to repeat treatment.

3.4.5. Serum electrolyte measurements

3.4.5.1. Serum potassium

Two articles including a total of 438 patients assessed the change in serum potassium levels before and after colonoscopy preparation (13, 14) and found that levels decreased in both groups. Heterogeneity testing showed that there was significant heterogeneity among the RCTs (P = 0.03) so the random effect model was used. Meta-analysis results showed that the NaPTab group had a greater decrease in serum potassium than the PEGL group [MD = 0.38, 95% CI (0.13–0.62), P = 0.006] (Figure 9).

FIGURE 9
www.frontiersin.org

Figure 9. Changes in serum potassium (mEq/L).

3.4.5.2. Blood calcium

Two articles including a total of 438 patients assessed the change in serum calcium before and after colonoscopy preparation (13, 14) and found that levels decreased in both groups. Heterogeneity testing revealed significant heterogeneity among the RCTs (P = 0.006) so a random effect model was used. Meta-analysis results showed that the decrease in serum calcium was greater in the NaPTab group than in the PEGL group [MD = 0.41, 95% CI (0.04–0.77), P = 0.03] (Figure 10).

FIGURE 10
www.frontiersin.org

Figure 10. Changes in blood calcium (mg/dL).

3.4.5.3. Blood phosphorus

Two articles including 438 patients assessed the change in serum phosphorus (inorganic) before and after colonoscopy preparation (13, 14). While patients in the NaPTab group had high serum phosphorus levels after preparation, some patients in the PEGL group had increased serum phosphorus levels while others had decreased levels. Heterogeneity testing revealed significant heterogeneity among the RCTs (P < 0.0001) so the random effect model was employed. Meta-analysis results showed that the NaPTab group had a greater increase in serum phosphate than the PEGL group [MD 4.51, (95% CI 2.9–6.11), P < 0.00001] (Figure 11).

FIGURE 11
www.frontiersin.org

Figure 11. Changes in blood phosphorus (mg/dL).

3.5. Sensitivity analysis and publication bias

A sensitivity analysis of adequate cleansing quality by omitting one study at a time did not fundamentally influence the pooled RR, suggesting that the combined RR was valid and credible. No evidence of publication bias was observed when the difference of adequate cleansing quality between NaPTab and PEGL were assessed (Figure 12).

FIGURE 12
www.frontiersin.org

Figure 12. Funnel chart of bowel cleaning quality.

4. Discussion

Colonoscopy has been used in medicine for over half a century. Many primary hospitals are now implementing this technique since it allows direct examination of the colonic mucosa. However, inadequate bowel preparation can make it difficult to clearly observe mucous membranes (3), resulting in missed diagnosis, or wasted time repeating the examination. Inadequate intestinal preparation can also increase the risk of intestinal perforation and peritonitis. If the intestine still includes a high amount of feces, high-frequency electronic resection can risk igniting any intestinal gas and result in explosion (24). A systematic review of 18 randomized controlled trials comparing sodium phosphate and polyethylene glycol solution was published in 2005. This review showed no differences in intestinal cleaning quality between the two groups. Sub-group analysis showed that the intestinal cleaning quality of NaPTab was significantly higher than PEGL (25). However, only 1,044 cases were included and no quantitative analysis of adverse reactions, patient acceptance, or electrolyte changes were assessed.

The current study collected 13 RCT studies that compared the success of intestinal preparation using NaPTab or PEGL prior to colonoscopy. Eight trials including 2,605 patients compared the effects of intestinal cleaning. Meta-analysis results showed that the NaPTab group was more likely to have an excellent and good rating of intestinal cleaning quality than the PEGL group (RR 1.02, 95% CI 0.96–1.08); however, the difference was not significant. Subgroup analysis showed that the NaPTab subgroup of more than 32 had a higher excellent and good rating of intestinal cleaning quality than the PEGL group (p = 0.003), but only two studies was included. The NaPTab group also had a lower incidence of nausea, a higher excellent and good taste rating and a higher willingness to repeat the treatment than the PEGL group, and these differences were significant. Two trials including 438 patients detected changes in serum potassium, calcium, and phosphorus levels before and after intestinal preparation. Serum potassium and calcium levels decreased after intestinal preparation with both treatments but the change was statistically greater for the NaPTab group than the PEGL group. Meanwhile, blood phosphorus increased following both treatments but the rise was significantly higher for the NaPTab group.

Currently, there are both oral sodium phosphate solutions and tablets available on the market. This treatment provides a low-capacity method of intestinal preparation and is convenient for patients to use. NaPTab also has a good taste, is well-tolerated and has a similar effect on intestinal cleaning than PEGL. Subgroup analysis showed that higher dose NaPTab may have better cleaning effect. Constipation is an important and highly common risk factor for poor quality of intestinal preparation (26). At present, there is little consensus on bowel preparation for constipation patients. A recent meta-analysis found that OSP may result in superior colonic cleanliness when compared to PEGL, however, quality of evidence was low (27). OSP may be a better choice for patients with chronic constipation and colonic diverticulum. The reason may be that OSP is a hyperosmotic agent, which can cause intestinal dilatation, peristalsis and evacuation of intestinal contents by inhaling water into the lumen of bowel (28).

Polyethylene glycol based intestinal lavage is an isosmotic solution that passes through the bowel without absorption or secretion. PEGL has been safely used in patients with serum electrolyte imbalance, advanced liver insufficiency, acute and chronic renal failure and congestive heart failure. PEGL does not change the histological characteristics of colon mucosa and can be used in patients suspected of having inflammatory bowel disease without obscuring the diagnostic capabilities of colonoscopy or biopsy analysis. However, patients have to take large volumes of fluid in order to achieve a cathartic effect, and the taste of PEGL is poor. In order to avoid the problem of volume and taste, a PEGL containing ascorbic acid (ACS) was developed. Large doses of ascorbic acid that are not fully absorbed remain in the colon cavity, where it plays an osmotic role, so a small amount of PEG is required (29).

Changes in electrolyte levels are more obvious for patients in the NaPTab group after intestinal preparation. This is a particular concern for high blood phosphorus, which is associated with severe kidney damage. A study identified 21 patients with acute renal failure a few weeks after a colonoscopy preparation using OSP. While renal function improved for most patients, four patients required renal replacement therapy (30). In addition, between January 2006 and December 2007, the Food and Drug Administration (FDA) reported 171 patients with acute renal failure after using OSP. The Huashan Hospital of Fudan University described a 61-year-old male who suffered from acute phosphate nephropathy (APN). His serum creatinine was normal before the colonoscopy but increased to 248 μmol/L within 4 months after taking OSP. Von Kassa staining of his renal pathology indicated APN (31). Another study found that the risk of acute renal failure was three times higher for OSP than PEGL. After nearly 9 months, the serum creatinine levels of most patients did not return to baseline levels (32). The US FDA has published high risk factors associated with acute renal failure from sodium phosphate including advanced age, hypovolemia, acute and chronic kidney disease, using diuretics and other drugs that influence renal blood flow, and ACEI/ARB. Advanced age and renal function were also highly correlated with APN (33). High blood pressure (30) and inflammatory bowel disease (IBD) (34) are predisposing factors. Drugs that alkalize urine can decrease the precipitation threshold of calcium phosphate, so are was not recommended for use with OSP (35). OSP for bowel preparation was not recommended by the 2019 Guide of the European Society of Gastroenterology (ESGE) for routine use, but the quality of support studies was poor (36). While patients do not favor PEGL for intestinal preparation because of its poor taste and large oral capacity, this treatment carries a lower risk of electrolyte disorders and kidney damage than sodium phosphate and is preferred over OSP for high-risk patients (37).

There are various ways for bowel preparation before colonoscopy, and different population need different volume of lavage or dose possibly. Westerners are heavier in body weight and need larger in dose when preparing. In addition, many cases require individualized bowel preparation based on risk factors. There are many risk factors for poor intestinal preparation, such as history of abdominal surgery. There are some possible explanations for the poor intestinal preparation in patients with a history of abdominal surgery. First of all, the patient has a decreased intestinal motility after intestinal resection. Second, after abdominal surgery, intra-abdominal adhesion may lead to the fixation of flexible intestine, which may lead to local retention of fecal substances. A study shown that gastric/small intestinal surgery was a potential risk factor for poor bowel preparation (38). According to the different conditions of abdominal surgery, except for using appropriate amount of intestinal cleanser, we can also choose prokinetic drugs, diet restrictions and other measures. Increased BMI is not predictive of poor bowel preparation for colonoscopy (39). In fact, the opposite is true for a particular group of patients, as it shows that the quality of bowel preparation is reduced for underweight females who are older than 70 years and have constipation, thus causing unfavorable colonoscopy outcomes (40). For such patients, if she has no risk factors of electrolyte disorder and acute phosphate nephropathy, she can consider using OSP. If yes, consider PEGL-ACS.

In conclusion, the current meta-analysis showed that NaPTab and PEGL have a similar cleaning effect before colonoscopy and that the tolerance of NaPTab is superior to PEGL. However, NaP tablets have a stronger effect on serum potassium, calcium and phosphorus levels. For patients with low potassium, low calcium and renal insufficiency, NaP tablets should be prescribed with caution. For patients at high risk for acute phosphate nephropathy, NaP tablets should be avoided. These conclusions are limited by both the number and quality of included studies and require verification by larger and more high-quality studies. Individualized bowel preparation based on risk factors is required for special cases. Good cleaning effect, low capacity, good taste, few adverse reactions and high security are goals to consider for the design of future intestinal preparations before colonoscopy. More clinical trials are required to evaluate relevant drugs or methods.

Data availability statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.

Author contributions

All authors listed have made a substantial, direct, and intellectual contribution to the work and approved it for publication.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Marshall JB, Pineda JJ, Barthel JS, King PD. Prospective, randomized trial comparing sodium phosphate solution with polyethylene glycol-electrolyte lavage for colonoscopy preparation. Gastrointest Endosc. (1993) 39:631–4. doi: 10.1016/S0016-5107(93)70213-8

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Church JM. Effectiveness of polyethylene glycol antegrade gut lavage bowel preparation for colonoscopy-timing is the key! Dis. Colon Rectum. (1998) 41:1223–5. doi: 10.1007/BF02258217

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Toledo TK, Dipalma JA. Colon cleansing preparation for gastrointestinal procedures. Aliment Pharmacol Ther. (2001) 15:605–11. doi: 10.1046/j.1365-2036.2001.00966.x

PubMed Abstract | CrossRef Full Text | Google Scholar

4. DiPalma JA, Brady CE. Colon cleansing for diagnostic and surgical procedures: polyethylene glycol-electrolyte lavage solution. Am J Gastroenterol. (1989) 84:1008–16.

PubMed Abstract | Google Scholar

5. Saltzman JR, Cash BD, Pasha SF, et al. Bowel preparation before colonoscopy. Gastrointest Endosc. (2015) 81:781–94. doi: 10.1016/j.gie.2014.09.048

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Thomas G, Brozinsky S, Isenberg JI. Patient acceptance and effectiveness of a balanced lavage solution (Golytely) vs. the standard preparation for colonoscopy. Gastroenterology. (1982) 82:435–7. doi: 10.1016/S0016-5085(82)80390-9

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Barkun A, Chiba N, Enns R, Marcon M, Natsheh S, Pham C, et al. Commonly used preparations for colonoscopy: efficacy, tolerability, and safety—A Canadian Association of gastroenterology position paper. Can J Gastroenterol. (2006) 20:699–710. doi: 10.1155/2006/915368

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Hookey LC, Depew WT, Vanner S. The safety profile of oral sodium phosphate for colonic cleansing before colonoscopy in adults. Gastrointest Endosc. (2002) 56:895–902. doi: 10.1016/S0016-5107(02)70367-2

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Aronchick CA, Lipshutz WH, Wright SH, Dufrayne F, Bergman GA. novel tableted purgative for colonoscopic preparation: efficacy and safety comparisons with Colyte and Fleet Phospho-Soda. Gastrointest Endosc. (2000) 52:346–52. doi: 10.1067/mge.2000.108480

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Moher D, Liberati A, Tetzlaff J, Altman DG, Group TP. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. (2009) 6:e1000097. doi: 10.1371/journal.pmed.1000097

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Clarke M, Oxman AD. “Cochrane Reviewers Handbook 4, 1.” [updated June 2000], in Review Manager (RevMan) [computerprogram] [CD/M]Version 4.1. Oxford, England: The Cochrane Collaboration (2000).

Google Scholar

12. Kastenberg D. Efficacy and safety of sodium phosphate tablets compared with PEG solution in colon cleansing: two identically designed, randomized, controlled, parallel group, multicenter phase III trials. Gastrointest Endosc. (2001) 54:705–13. doi: 10.1067/mge.2001.119733

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Johanson JF. A randomized, multicenter study comparing the safety and efficacy of sodium phosphate tablets with 2L polyethylene glycol solution plus bisacodyl tablets for colon cleansing. Am J Gastroenterol. (2007) 102:2238–46. doi: 10.1111/j.1572-0241.2007.01363.x

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Aihara H. Comparison of two sodium phosphate tablet-based regimens and a polyethylene glycol regimen for colon cleansing prior to colonoscopy: a randomized prospective pilot study. Int J Colorectal Dis. (2009) 24:1023–30. doi: 10.1007/s00384-009-0735-x

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Kastenberg D, Barish C, Burack H. INKP-00 Study Group. Tolerability and patient acceptance of sodium phosphate tablets compared with 4-L PEG solution in colon cleansing: combined results of 2 identically designed, randomized, controlled, parallel group, multicenter phase 3 trials. J. Clin. Gastroenterol. (2007) 41:54–61. doi: 10.1097/01.mcg.0000212662.66644.76

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Lichtenstein GR, Grandhi N, Schmalz M, Zhang B. Clinical trial: sodium phosphate tablets are preferred and better tolerated by patients compared to polyethylene glycol solution plus bisacodyl tablets for bowel preparation. Aliment Pharmacol Ther. (2007) 26:1361–70. doi: 10.1111/j.1365-2036.2007.03496.x

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Hosoe N, Nakashita M, Imaeda H, Ogata H. Comparison of patient acceptance of sodium phosphate versus polyethylene glycol plus sodium picosulfate for colon cleansing in Japanese. J Gastroenterol Hepatol. (2012) 27:1617–22. doi: 10.1111/j.1440-1746.2012.07190.x

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Kambe H, Yamaji Y, Sugimoto T, Yamada A, Watabe H, Yoshida H, et al. A randomized controlled trial of sodium phosphate tablets and polyethylene glycol solution for polyp detection. J Dig Dis. (2012) 13:374–80. doi: 10.1111/j.1751-2980.2012.00588.x

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Jung YS, Lee CK, Kim HJ, Eun CS, Han DS, Park DI, et al. Randomized controlled trial of sodium phosphate tablets vs polyethylene glycol solution for colonoscopy bowel cleansing. World J Gastroenterol. (2014) 20:15845–51. doi: 10.3748/wjg.v20.i42.15845

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Seung-Hwa L. Comparison of the efficacy and safety of sodium phosphate tablets and polyethylene glycol solution for bowel cleansing in healthy Korean adults. Yonsei Med J. (2014) 55:1542–55. doi: 10.3349/ymj.2014.55.6.1542

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Kumagai E. A Randomized prospective study of bowel preparation for colonoscopy with low-dose sodium phosphate tablets versus polyethylene glycol electrolyte solution. Gastroenterol Res Pract. (2014) 2014:879749. doi: 10.1155/2014/879749

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Ako S, Takemoto K, Yasutomi E, Sakaguchi C, Murakami M, Sunami T, et al. Comparing reduced-dose sodium phosphate tablets to 2 L of polyethylene glycol: a randomized study. World J Gastroenterol. (2017) 23:4454–61. doi: 10.3748/wjg.v23.i24.4454

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Chaussade S, Schmöcker C, Toulemonde P, Henri F. Phosphate tablets or polyethylene glycol for preparation to colonoscopy? A multicentre non-inferiority randomized controlled trial. Surg Endosc. (2017) 31:2166–73. doi: 10.1007/s00464-016-5214-1

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Bond JH, Levitt MD. Colonic gas explosion-is a fire extinguisher necessary? Gastroenterol. (1979) 77:1349–50. doi: 10.1016/0016-5085(79)90178-1

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Li Y, Wang Y, Pan T, Tian L. Oral sodium phosphate versus polyethylene glycol-electrolyte lavage solution for colonoscopy preparation: a systematic review. Chin JEBM. (2005) 7:555–61.

Google Scholar

26. Anderson JC, Messina CR, Cohn W, Gottfried E, Ingber S, Bernstein G, et al. Factors predictive of difficult colonoscopy. Gastrointest Endosc. (2001) 54:558–62. doi: 10.1067/mge.2001.118950

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Dang JT, Moolla M, Dang TT, Shaw A, Tian C, Karmali S, et al. Sodium phosphate is superior to polyethylene glycol in constipated patients undergoing colonoscopy: a systematic review and meta-analysis. Surg Endosc. (2021) 35:900–9. doi: 10.1007/s00464-020-07464-0

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Mamula P, Adler DG, Conway JD, Diehl DL, Farraye FA, Kantsevoy SV, et al. Colonoscopy preparation. Gastrointest Endosc. (2009) 69:1201–9. doi: 10.1016/j.gie.2009.01.035

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Shawki S, Wexner SD. Oral colorectal cleansing preparations in adults. Drugs. (2008) 68:417–37. doi: 10.2165/00003495-200868040-00003

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Markowitz GS, Stokes MB, Radhakrishnan J. Acute phosphate nephropathy following oral sodium phosphate bowel purgative:an underrecognized cause of chronic renal failure. J Am Soc Nephrol. (2005) 16:3389–96. doi: 10.1681/ASN.2005050496

PubMed Abstract | CrossRef Full Text | Google Scholar

31. Wang Y, Xie Q, Liu S, Xux J, Hao C. A case of acute phosphate nephropathy (APN) caused by oral sodium phosphate (OSP). Fudan Univ J Med Sci. (2020) 2:297–300.

Google Scholar

32. Hurs FP, Bohen EM, Osgard EM. Association of oral sodium phosphate purgative use with acute kidney injury. J Am Soc Nephrol. (2007) 18:3192–8. doi: 10.1681/ASN.2007030349

PubMed Abstract | CrossRef Full Text | Google Scholar

33. Aainley EJ, Winwood PJ, Begley JP. Measurement of serum electrolytes and phosphate after sodium phosphate colonoscopy bowel preparation:an evaluation. Dig Dis Sci. (2005) 50:1319–23. doi: 10.1007/s10620-005-2780-9

PubMed Abstract | CrossRef Full Text | Google Scholar

34. Hookey LC, Vanner S. Recognizing the clinical contraindications to the use of oral sodium phosphate for colon cleansing: a case study. Can J Gastroenterol. (2004) 18:455–8. doi: 10.1155/2004/787515

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Desmeules S, Bergeron MJ, Isenring P. Acute phosphate nephropathy and renal failure. N Engl J Med. (2003) 349:1006–7. doi: 10.1056/NEJM200309043491020

PubMed Abstract | CrossRef Full Text | Google Scholar

36. Hassan C, East J, Radaelli F. Bowel preparation for colonoscopy: European society of gastrointestinal endoscopy (ESGE) guideline—Update 2019. Endoscopy. (2019) 51:775–94. doi: 10.1055/a-0959-0505

PubMed Abstract | CrossRef Full Text | Google Scholar

37. Kan WC, Wang HY, Chien CC. Intermediate bioelectrolyte changes after phospho-soda or polyethylene glycol precolonoscopic laxatives in a population undergoing health examinations. Nephrol Dial Transplant. (2012) 27:752–7. doi: 10.1093/ndt/gfr189

PubMed Abstract | CrossRef Full Text | Google Scholar

38. Kim B, Kim BC, Kim J, Oh HJ, Ryu KH, Park BJ. Quality of bowel preparation for colonoscopy in patients with a history of abdomino-pelvic surgery: retrospective cohort study. Yonsei Med J. (2019) 60:73–8. doi: 10.3349/ymj.2019.60.1.73

PubMed Abstract | CrossRef Full Text | Google Scholar

39. Anklesaria AB, Ivanina EA, Chudy-Onwugaje KO, Tin K, Levine CM, Homel P, et al. The effect of obesity on the quality of bowel preparation for colonoscopy: results from a large observational study. J Clin Gastroenterol. (2019) 53:e214–20. doi: 10.1097/MCG.0000000000001045

PubMed Abstract | CrossRef Full Text | Google Scholar

40. Mohammed RA, Lafi SY. Effect of body size on quality of bowel preparation among patients experiencing colonoscopy. Gastroenterol Nurs. (2021) 44:122–8. doi: 10.1097/SGA.0000000000000557

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: colonoscopy, bowel preparation, sodium phosphate, polyethylene glycol electrolyte lavage solution, meta-analysis, systematic review

Citation: Yao-dong L, Yi-ping W, Gang M, Yang-yun H, Ling-ling Z, Hong D, Jia-zheng D, Rong-chao X, You-wei L, Ming Z, Shun-bin D, Jing L, Yang S, Jia-qi D, Lei D, Xiong-feng S, You-jian Z and Zuo-qiong Z (2023) Comparison of oral sodium phosphate tablets and polyethylene glycol lavage solution for colonoscopy preparation: a systematic review and meta-analysis of randomized clinical trials. Front. Med. 10:1088630. doi: 10.3389/fmed.2023.1088630

Received: 17 December 2022; Accepted: 11 May 2023;
Published: 26 May 2023.

Edited by:

Angel Lanas, University of Zaragoza, Spain

Reviewed by:

Mitsushige Sugimoto, Tokyo Medical University Hospital, Japan
Luiz Jardelino De Lacerda Neto, Federal University of Campina Grande, Brazil

Copyright © 2023 Yao-dong, Yi-ping, Gang, Yang-yun, Ling-ling, Hong, Jia-zheng, Rong-chao, You-wei, Ming, Shun-bin, Jing, Yang, Jia-qi, Lei, Xiong-feng, You-jian and Zuo-qiong. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Li Yao-dong, 16167050@qq.com

ORCID: Zhu Ling-ling orcid.org/0000-0002-4740-2838
Zhou Zuo-qiong orcid.org/0000-0001-9086-0431

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.