ORIGINAL RESEARCH article

Front. Endocrinol., 19 August 2022
Sec. Clinical Diabetes
This article is part of the Research Topic Daily Challenges Around Physical Exercise, Nutrition and Medication in Type 1 Diabetes View all 9 articles

Ana Gianini,Ana Gianini1,2Jana SuklanJana Suklan3Brigita Skela-Savi
Brigita Skela-Savič4Simona KlemencicSimona Klemencic1Tadej Battelino,Tadej Battelino1,2Klemen Dovc,Klemen Dovc1,2Nata&#x;a Bratina,*Nataša Bratina1,2*
  • 1Department of Pediatric Endocrinology, Diabetes and Metabolic Diseases, University Children’s Hospital, University Medical Centre Ljubljana, Ljubljana, Slovenia
  • 2Slovenia and Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
  • 3NIHR Newcastle In Vitro Diagnostics Co-operative, Faculty of Medical Sciences, Translational and Clinical Research Institute, Newcastle University, Newcastle upon Tyne, United Kingdom
  • 4Department for Masters and Phd in Health Care Science, Angela Boškin Faculty of Health Care, Jesenice, Slovenia

Purpose: To determine the impact of advanced hybrid closed - loop (AHCL) insulin delivery on quality of life, metabolic control and time in range (TIR) in youth with type 1 diabetes mellitus (T1DM).

Methods: Twenty-four children and adolescents with T1DM (14 female) aged of 10 to 18 years participated in the study. Mixed methods study design was implemented. Quantitative part of the study was conducted as a longitudinal crossover study with data collection before and at the end of AHCL use. Qualitative data were obtained with modeled interviews of four focus groups before and the end of the period. Clinical data were collected from the electronic medical records.

Results: The use of AHCL significantly improved the quality of life in terms of decreased fear of hypoglycemia (p<0.001), decrease in diabetes-related emotional distress (p<0.001), and increased wellbeing (p=0.003). The mean A1C decreased from 8.55 ± 1.34% (69.9 ± 12.3 mmol/mol) to 7.73 ± 0.42 (61.1 ± 2.2 mmol/mol) (p=0.002) at the end of the study. Mean TIR was 68.22% (± 13.89) before and 78.26 (± 6.29) % (p<0.001) at the end of the study.

Conclusion: The use of advanced hybrid closed loop significantly improved the quality of life and metabolic control in children and adolescents with T1DM.

Introduction

Type 1 diabetes (T1DM) is one of the most common chronic conditions in children and adolescents all over the world with an increasing incidence of approximately 3.4% per year in Europe (1). The principal goal in the management of T1DM is to maintain blood glucose levels as close to normal as possible with the aim of avoiding or delaying disease-related micro and macrovascular complications, which represent the major cause of morbidity and mortality in developed societies (2, 3). The majority of people with T1DM does not achieve glycated hemoglobin (A1C) below 7% (53 mmol/mol) (4), as suggested by all major guidelines (5). The use of technology in the management of T1DM is becoming the predominant component of care, often first with a continuous glucose monitor and an insulin pump as needed, and most recently with systems combining the two into an automated closed-loop insulin delivery system (6, 7). The use of closed-loop systems as an acceptable therapeutic modality for management of T1DM has been the focus of many recent studies. There is a growing body of evidence that advanced hybrid closed loop (AHCL) systems improve glycemic control irrespective of baseline A1C, while simultaneously decrease the rates of hypoglycemic events (8, 9). Glycemic control using AHCL is maintained particularly well overnight, which is of great importance to parents of children with T1DM who experience significant fear of undetected hypoglycemia and hyperglycemia during the sleep (10, 11). AHCL insulin delivery, characterized by automated insulin delivery apart from prandial boluses, now represents routine clinical care for people with T1DM (1217). The most recent data clearly confirm the ability of the AHCL insulin delivery systems to safely achieve a significant improvement of glucose control in T1DM (18).

In our study we aimed at determining the impact of AHCL usage on patient reported outcome measures.

Methods

We utilized a mixed methods research design using a quantitative and a qualitative part. Data were obtained from a cohort longitudinal crossover study in which same participants were investigated at two different points in time.

Study participants were identified from the Slovenian National Diabetes Registry and invited to participate in the study through outpatient clinic, National Diabetes Society webpage, and social media. Study was conducted at the University Children’s Hospital in Ljubljana, Slovenia, which is a national center for childhood diabetes (19).

Ethical approval was obtained from the Slovenian National Medical Ethics Committee. All participants and their parent or legal guardian signed informed consent prior to the enrolment in the study.

Inclusion/exclusion criteria

Inclusion criteria: participants were 10 - 18 years old (inclusive), had clinical diagnosis of T1DM for at least 6 months, and were using an insulin pump for at least 3 months. Exclusion criteria included concomitant diseases that could influence metabolic control or compromise a participant’s safety.

Procedures

Data were obtained first before the start of AHCL usage, when conventional therapy was used, and again after 4 months at the end of the study. At baseline (conventional therapy), one participant was using insulin pump without continuous glucose monitoring (CGM), nine participants were using insulin pump with intermittently scanned CGM, four were using predictive low glucose suspend system (PLGS) and 10 were using first generation hybrid closed-loop device (HCL). During the study, participants were using a modified investigational version of Minimed 780G (Medtronic, USA) (AHCL). Compared to first generation HCL, AHCL includes several algorithmic developments and features with the aim of remaining in closed-loop for longer periods of time without compromising safety, including automated correction boluses.

Upon entry into the study, all participants began to use AHCL and received structured education. Validated questionnaires were applied, and downloads from their previous sensor and insulin pump were obtained along with the clinical data from the electronic medical record.

The participants answered 3 validated questionnaires: C-HFS – Children, Hypoglycemia Fear Survey; PAID Problem Areas in Diabetes Scale; PAID-5 Problem Areas in Diabetes Scale—Five-item short form; WHO-5 Five Item Measure of Wellbeing.

The C-HFS is validated for youth to assess their Fear of Hypoglycemia (FoH). It consists of two subscales: a Behavior subscale (11-items) and a Worry subscale (15-items). The Behavior subscale measures the behaviors of children and adolescents to prevent hypoglycemic episodes and their consequences, similarly the Worry subscale measures concerns related to hypoglycemia and its negative consequences. Items are rated on a 5-point Likert scale (1 = “never” to 5 = “almost always”). Questionnaire scores are computed as a total score divided by the total number of items to obtain an item mean score. Higher scores indicate higher FoH.

Problem Areas in Diabetes (PAID) is another well-validated and commonly used 20 items questionnaire used for measuring diabetes-related emotional distress, covering negative emotional problems. Items are rated on a 5-point Likert scale (0 = “not a problem” to 4 = “serious problem”). Questionnaire scores are computed as a total sum is multiplied by 1.25 to produce a final possible score of 0–100, with higher scores indicating greater diabetes-related emotional distress.

The World Health Organization–Five Well-Being Index (WHO-5) is a short self-report measure of subjective well-being with good psychometric properties. The scale measures the degree to which the positive feelings were present in the last 2 weeks is scored on 6-point Likert scale ranging from 0 (not present) to 5 (constantly present). The total raw score, ranging from 0 to 25, is multiplied by 4 to give the final score, 0 (worst thinkable well-being) to 100 (best thinkable well-being). A score < 50 suggests poor emotional well-being, while a score ≤ 28 is indicative of depression.

In the qualitative part of the study, we conducted focus groups with modelled interviews in order to obtain data that could not be obtained with the quantitative methods. Focus groups were conducted twice: first at study entry when conventional therapy was used, and second at the end of the study after 4 months of AHCL use. Children and adolescents were separated into four focus groups. The facilitator used a semi-structured questionnaire to present the main topic for discussion and a set of ‘ground rules’ as well as relevant ethical issues around data capture, storage and dissemination. The reliability of the study was ensured by the sufficient number of focus groups, and the number of participants in each group. A focus groups discussions continued until data saturation was reached (20). We audio-recorded the focus group’s conversations and performed transcripts of the recordings.

Statistical analyses

Cronbach alpha was used to calculate the scale reliability (internal consistency) of the measurement scale. Paired sample two-tailed t-test with Holm – Bonferroni sequential multiplicity correction (21) was used to compare mean values from the beginning of the study with mean values from the end of the study adjusting for multiple comparisons. Since we conducted 9 comparisons, we are only able to reject the null hypothesis of each comparison if it has a p-value less than 0.006. The analysis of the data was done using IBM SPSS Statistics for Windows 27.0.

Results

In total, 24 participants (14 females) with T1DM on insulin pump were enrolled and competed the study (mean age 14.5 ± 1.7 years, T1DM duration mean 7.2 ± 3.7 years) (Table 1), among them 17 school-aged children (10-14 years) and 7 adolescents (15-18 years). The average use of the insulin pump was 6.3 ± 4.2 years.

TABLE 1
www.frontiersin.org

Table 1 Baseline characteristics.

Patient-reported outcome measures (PROMs)

Patient-reported outcome measures were gathered using 3 validated, standardized questionnaires (C-HFS, PAID, WHO-5). All participants (n=24) included in the study completed all 3 questionnaires at the beginning and at the end of the study. Data suggest acceptable internal consistency of the sample with alpha values ranging from 0.866 to 0.925 (Table 2).

TABLE 2
www.frontiersin.org

Table 2 Scale score reliability.

Fear of hypoglycemia

The combined results (behavior and worry subscale) showed a statistically significant decrease of fear of hypoglycemia with the use of AHCL. Statistical significance was calculated for all three groups (behavior, worry subscale and combined results) (Table 3).

TABLE 3
www.frontiersin.org

Table 3 Comparison of average Behavior and Worry, C-HFS total score with a post - hoc analysis for participants with A1C < 7% (< 53 mmol/mol) versus A1C ≥ 7% (≥ 53 mmol/l).

A post hoc breakdown comparison between children and adolescents with A1C < 7% (< 53 mmol/mol) versus children and adolescents with A1C ≥ 7% (≥ 53 mmol/mol) at the beginning and the end of the study also showed a reduction in fear of hypoglycemia with the use of AHCL in both < 7% (< 53 mmol/mol) and ≥ 7% (≥ 53 mmol/mol) (Table 3).

PAID problem areas in diabetes scale

The results show a statistically significant reduction in diabetes-related emotional distress from 19.3 ± 12.3 to 8.6 ± 8.3 (p>0.001) with the use of AHCL.

A post – hoc breakdown comparison children and adolescents with A1C < 7% (< 53 mmol/mol) versus children and adolescents with A1C ≥ 7% (≥ 53 mmol/mol) at the beginning of the study also shows a reduction in diabetes – related emotional distress with the use of AHCL in both < 7% (< 53 mmol/mol) and ≥ 7% (≥ 53 mmol/mol) (Table 4).

TABLE 4
www.frontiersin.org

Table 4 Post – hoc comparison of average PAID Problem Areas in Diabetes Scale among children and adolescents with A1C < 7% (< 53 mmol/mol) versus children and adolescents with A1C ≥ 7% (≥ 53 mmol/mol).

WHO-5 five item measure of wellbeing

The average WHO-5 score of well-being was increased from the beginning of the study (68.17 ± 16.83) compared to the end of the study (80.50 ± 14.02) (p=0.03). The significance was not below the adjusted threshold off p<0.006 (p=0.03).

A post – hoc breakdown comparison between children and adolescents with A1C < 7% (< 53 mmol/mol) versus children and adolescents with A1C ≥ 7% (≥ 53 mmol/mol) at the beginning of the study also shows an increase in WHO-5 well-being score with the use of AHCL in both A1C < 7% (< 53 mmol/mol) and ≥ 7% (≥ 53 mmol/mol) subgroups (Table 5) with no statistically significant difference within the group with higher A1c at baseline (t (13) = -2.08, p =0.058, Cohen’s d (based on differences) with Hedges correction = 0.54 (medium/moderate size effect). The group with lower A1c at baseline shows a statistically significant increase in quality of life (t (9) = -3.74, p = 0.005, Cohen’s d (based on differences) with Hedges correction = 1.13 (very large/strong size effect).

TABLE 5
www.frontiersin.org

Table 5 Post – hoc comparison of average World Health Organization – Five Well – Being score (WHO-5) among children and adolescents with A1C < 7% (< 53 mmol/mol) versus children and adolescents with A1C ≥ 7% (≥53 mmol/mol).

Correlations among questionnaires’ results

In the A1C ≥ 7% (≥ 53 mmol/mol) subgroup of children and adolescents at the beginning of the study we observed a statistically significant negative correlation between PAID-20 and WHO-5 scores (r=0.546, p=0.043) indicating that increased diabetes-related emotional distress had a negative impact on the well-being of children and adolescents. We also observed a positive correlation between PAID-20 and CHFS total (r= 0.552, p = 0.041) indicating that diabetes-related emotional distress is correlated with fear of hypoglycemia. This was also observed in the < 7% (< 53 mmol/mol) subgroup of children and adolescents at the end of the study (r= 0.635, p= 0.027). There were no statistically significant correlations among other subgroups.

Focus groups interviews

In the analysis of the interviews the baseline transcripts revealed 24 categories and 157 codes. The analysis of the qualitative data gathered after the introduction of AHCL generated 17 categories and 122 codes. Participants emphasized exhaustion with disease management, quality of sleep, and school related stress with dysglycemia.

Based on these results we confirmed that the burden of T1DM management was lower with the use of AHCL. We also confirmed that average well-being increased with the use AHCL. Additionally, the quality of life experienced by children and adolescents with T1DM using AHCL has increased (Table 6).

TABLE 6
www.frontiersin.org

Table 6 Results: Focus groups interviews.

TABLE 7
www.frontiersin.org

Table 7 Clinical and glycemic data.

The participants were more rested, worried less about their illness, and consequently had more time for other things. A notable improvement in the quality of sleep of both - participants and their parents were reported. The use of AHCL contributed to the increase in the quality of life. The use of AHCL was reported to bring less stress in disease management and was consequently less exhausting. The management of T1DM was easier, as reflected also in improved metabolic control.

Metabolic control

The average value of A1C at the beginning of the study (8.55 ± 1.34% (69.9 ± 12.3 mmol/mol)) was significantly higher than at the end (7.74 ± 0.42% (61.1 ± 2.2 mmol/mol)) TIR differed significantly between the use of conventional therapy 68.22 ± 3.69% and AHCL 78.26 ± 6.29 (p<0.001). The TBR, did not differ significantly between the two types of treatment, neither for TBR <3.0 mmol/L (p=0.577), nor TBR <3.9 mmol/L (p=0.276). The Time above range (TAR) was significant less for the AHCL: TAR > 10 mmol/L (p=0.001) and TAR > 13.9 mmol/L (p=0.006) (Table 7). No severe hypoglycemia or diabetic ketoacidosis were reported.

Conclusions

The standardized PROMs (C-HFS, PAID, WHO-5) were used to assess the observed benefits of using AHCL over a conventional therapy. All three scales were sufficiently reliable for the use as independent measures. Our results showed a significant decrease of Fear of Hypoglycemia, a reduction in diabetes-related emotional distress, and an increase in general well-being as reported by the participants. There was an overall rise in participants’ satisfaction with the use of AHCL as compared to the conventional therapy, less exhaustion, and a higher quality of life. Children and adolescents reported lower levels of fear, emotional distress, and increased well-being related to their T1DM. A recent clinical trial evaluating AHCL reports improved results from emotional burden scale, and behavioral burden, but no changes in distress or hypoglycemia confidence; it is of interest that satisfaction was greater in those who were more frequently in auto-mode (22). A group from Australia also showed improved glycemic control and improved diabetes treatment satisfaction as a possible consequence of reduced worry and increased trust in AHCL (23).

Our qualitative results indicated reduced exhaustion and increased sleep quality. Participants spent less time managing TIDM using the AHCL indicating reduced disease burden. Similarly, a study with a different AHCL also reports increased quality of life with AHCL usage (24).

Additionally, the quality of life experienced by children and adolescents with T1DM increased with the use of AHCL. This was accompanied by an increased satisfaction of their parents. Recently, data for a randomized controlled trial also demonstrated increase glucose monitoring satisfaction with the use of AHCL (22).

Our study showed that children and adolescents with T1DM had better metabolic control using AHCL. Different studies report that metabolic control with AHCL usage is significantly improved (25, 26). A recent trial shows that participants treated with AHCL had fewer episodes of hyperglycemia, and the TIR improved (27). The AHCL system can be used safely in children and adolescents with T1DM without episodes of severe hypoglycemia or diabetic ketoacidosis (24), as was also demonstrated in our study.

Different studies demonstrated that users of AHCL have less hypoglycemia (21, 2533). In our study, the TBR was low already at the beginning of the study and remained low at the end of study. Noteworthy, a majority of participants were using CGM at baseline and approximately half of them were using PLGS or first generation HCL. Participants spent less time in TAR when treated with AHCL, as demonstrated in several other studies (30, 34).

In conclusion, patient reported outcome measures and qualitative assessment demonstrated decreased fear of hypoglycemia, less emotional distress, increased quality of life and reduced burden of disease management with the use of AHCL. These outcomes were related to improved measures of metabolic control.

Limitations

Our study has limitations: a single center was included, and the sample size was relatively small. Additionally, the duration of the trial was limited.

Implications/relevance for diabetes educators

Our study demonstrated novel data on the quality of life improvement in children and adolescent with T1DM. This new knowledge could complement our standardized diabetes education programs both at disease onset as well as our educational programs for therapy intensification, particularly when introducing AHCL.

Data availability statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.

Ethics statement

The studies involving human participants were reviewed and approved by Slovenian National Medical Ethics Committee. Written informed consent to participate in this study was provided by the participants’ legal guardian/next of kin.

Author contributions

AG, KD, NB, and TB contributed to the study concept and design. NB and TB supervised the study. AG, JS, BS, KD, JS, and NB collected data, JS performed statistical analyses. All authors participated in data analysis and interpretation. The manuscript was drafted by AG, NB, and TB, and reviewed by all authors. NB and TB are the guarantors of this work and, as such, had full access to all the data in the study and takes responsibility for the integrity of the data and the accuracy of the data analysis. All authors read and approved the final submitted version of the manuscript.

Funding

The study was supported in part by the Slovenian Research Agency front # P3-0343, and University Medical Center Ljubljana grant # 20200234.

Acknowledgments

We thank all participants and their parents, and the diabetes team, particularly the CDEs.

Conflict of interest

TB served on advisory boards of Novo Nordisk, Sanofi, Eli Lilly, Boehringer, Medtronic, Indigo and DreaMed Diabetes; received honoraria for participating on the speaker’s bureaux of Eli Lilly, NovoNordisk, Medtronic, Abbott, Sanofi, Aventis, Astra Zeneca and Roche;and owns stock from DreamMed Diabetes. TB’s institution received research grant support and TB received travel and accommodation expenses in some cases, from Abbott, Medtronic, Novo Nordisk, GluSense, Sanofi, Sandoz and Zealand Pharma. KD served on advisory boards of Eli Lilly and Pfizer; received honoraria for participating on the speaker’s bureaux of Abbott, Medtronic and NovoNordisk. KD is a member of the European Commission Expert panel for Medical Devices for Endocrinology and Diabetes. NB received honoraria for participation on the speaker’s bureau of Medtronic and Roche.

The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Patterson CC, Harjutsalo V, Rosenbauer J, Neu J, Cinek O, Skrivarhaug T, et al. Trends and cyclical variation in the incidence of childhood type 1 diabetes in 26 European centres in the 25 year period 1989–2013: A multicentre prospective registration study. Diabetologia (2019) 62(3):408–17. doi: 10.1007/s00125-018-4763-3

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Atkinson MA, Eisenbarth GS, Michels AW. Type 1 diabetes. Lancet (2014) 383:69–82. doi: 10.1016/S0140-6736(13)60591-7

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Lind M, Svensson AM, Kosiborod M, Gudbjornsdottir S, Pivodic HW, Dahlqvist S, et al. Glycemic control and excess mortality in type 1 diabetes. N Engl J Med (2014) 371:1972–82. doi: 10.1056/NEJMoa1408214

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Battelino T, Danne T, Bergenstal RM, Amiel SA, Beck R, Biester T, et al. Clinical targets for continuous glucose monitoring data interpretation: Recommendations from the international consensus on time in range. Diabetes Care (2019) 42(8):1593–603. doi: 10.2337/dci19-0028

PubMed Abstract | CrossRef Full Text | Google Scholar

5. American Diabetes Association. Diabetes technology: Standards of medical care in diabetes-2022. Diabetes Care (2022) 45(suppl 1):S97–S112.doi: 10.2337/dc22-s007

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Martin CT, Criego AB, Carlson AL, Bergenstal RM. Advanced technology in the management of diabetes: Which comes first-continuous glucose monitor or insulin pump? Curr Diabetes Rep (2019) 19(8):50. doi: 10.1007/s11892-019-1177-7

CrossRef Full Text | Google Scholar

7. Beck RW, Bergenstal RM, Laffel LM, Pickup JC. Advances in technology for management of type 1 diabetes. Lancet (2019) 394:1265–73. doi: 10.1016/S0140-6736(19)31142-0

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Dovc K, Piona C, Mutlu GY, Bratina N, Jenko Bizjan B, Lepej D, et al. Faster compared with standard insulin aspart during day-and-Night full closed-loop insulin therapy in type 1 diabetes: A double-blind randomized crossover trial. Diabetes Care (2020) 43(1):29–36. doi: 10.2337/dc19-0895

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Tauschmann M, Thabit H, Leelarathna L, Elleri D, Allen JM, Lubina-Solomon A, et al. Factors associated with glycemic control during free-living overnight closed-loop insulin delivery in children and adults with type 1 diabetes. J Diabetes Sci Technol (2015) 9(6):1346–47. doi: 10.1177/1932296815604439

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Strandberg RB, Graue M, Wentzel-Larsen T, Peyrot M, Wahl AK, Rokne B. The relationships among fear of hypoglycaemia, diabetes-related quality of life and psychological well-being in Norwegian adults with type 1 diabetes. Diabetes Res Clin Pract (2017) 124:11–9. doi: 10.1016/j.diabres.2016.12.018

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Hovorka R, Allen JM, Elleri D, Chassin LJ, Harris J, Xing D, et al. Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: A phase 2 randomised crossover trial. Lancet (2010) 375:743–51. doi: 10.1016/S0140-6736(09)61998-X

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Bergenstal RM, Garg S, Weinzimer SA, Buckingham BA, Bode BW, Tamborlane WV, et al. Safety of a hybrid closed-loop insulin delivery system in patients with type 1 diabetes. JAMA (2016) 316:1407–08. doi: 10.1001/jama.2016.11708

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Bekiari E, Kitsios K, Thabit H, Tauschmann M, Athanasiadou E, Karagiannis T, et al. Artificial pancreas treatment for outpatients with type 1 diabetes: systematic review and meta-analysis. BMJ (2018) 18:361 k1310. doi: 10.1136/bmj.k1310

CrossRef Full Text | Google Scholar

14. Forlenza GP, Pinhas-Hamiel O, Liljenquist DR, Shulman DI, Bailey TS, Bode BW, et al. Safety evaluation of the MiniMed 670G system in children 7-13 years of age with type 1 diabetes. Diabetes Technol Ther (2019) 21:11–9. doi: 10.1089/dia.2018.0264

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Garg SK, Weinzimer SA, Tamborlane WV, Buckingham BA, Bode BW, Bailey TS, et al. Glucose outcomes with the in-home use of a hybrid closed-loop insulin delivery system in adolescents and adults with type 1 diabetes. Diabetes Technol Ther (2017) 19(3):155–63. doi: 10.1089/dia.2016.0421

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Tauschmann M, Thabit H, Bally L, Allen JM, Hartnell S, Wilinsk ME, et al. Closed-loop insulin delivery in suboptimally controlled type 1 diabetes: a multicentre, 12-week randomised trial. Lancet (2018) 392:1321–29. doi: 10.1016/S0140-6736(18)31947-0

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Tauschmann M, Allen JM, Nagl K, Fritsch M, Yong J, Metcalfe E, et al. Home use of day-and-night hybrid closed-loop insulin delivery in very young children: a multicenter, 3-week, randomized trial. Diabetes Care (2019) 42:594–600. doi: 10.2337/dc18-1881

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Ferrito L, Passanisi S, Bonfanti R, Cherubini V, Minuto N, Schiaffini R, et al. Efficacy of advanced hybrid closed loop systems for the management of type 1 diabetes in children. Minerva Pediatr (2021) 73(6):474–85. doi: 10.23736/s2724-5276.21.06531-9

CrossRef Full Text | Google Scholar

19. Bratina N, Shalitin S, Phillip M, Battelino T. Type 1 diabetes in the young: Organization of two national centers in Israel and Slovenia. Zdr Varst. (2015) 54(2):139–45. doi: 10.1515/sjph-2015-0021

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Lowe A, Norris AC, Farris J, Babbage DR. Quantifying thematic saturation in qualitative data analysis. SAGE journals (2018) 30(3):191–207. doi: 10.1177/1525822X17749386

CrossRef Full Text | Google Scholar

21. Holm S. A simple sequentially rejective multiple test procedure. Scand J Stat (1979) 6(2):65–70.

Google Scholar

22. Hood KK, Laffel LM, Danne T, Nimri R, Weinzimer SA, Sibayan J, et al. Lived experience of advanced hybrid closed–loop versus hybrid closed–loop: Patient–reported outcomes and perspectives. Diabetes Technol Ther (2021) 23(12):857–61. doi: 10.1089/dia.2021.0153

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Abraham MB, Bock M, Smith GJ, Dart J, Fairchild JM, King BR, et al. Effect of a hybrid closed-loop system on glycemic and psychosocial outcomes in children and adolescents with type 1 diabetes. JAMA Pediatr (2021) 175(12):1227–35. doi: 10.1001/jamapediatrics.2021.3965

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Musolino G, Dovc K, Boughton CK, Tauschmann M., Aleen JM, Nagl K, et al. Reduced burden of diabetes and improved quality of life: Experiences from unrestricted day-and-night hybrid closed-loop use in very young children with type 1 diabetes. Pediatr Diabetes (2019) 20(6):794–99. doi: 10.1111/pedi.12872

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Grosman B, Ilany J, Roy A, Kurtz N, Wu D, Parikh N, et al. Hybrid closed–loop insulin delivery in type 1 diabetes during supervised outpatient conditions. J Diabetes Sci Technol (2016) 10(3):708–13. doi: 10.1177/1932296816631568

PubMed Abstract | CrossRef Full Text | Google Scholar

26. Anderson SM, Raghinaru D, Pinsker JE, Boscari F, Renard E, Buckingham B, et al. Multinational home use of closed-loop control is safe and effective. Diabetes Care (2016) 39(7):1143–50. doi: 10.2337/dc15-2468

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Usoh CO, Johnson CP, Speiser JL, Bundy R, Dharod A, Aloi JA, et al. Real-world efficacy of the hybrid closed-loop system. J Diabetes Sci Technol (2021) 16(3):659–662. doi: 10.1177/1932296820985103

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Fuchs J, Hovorka R. Closed-loop control in insulin pumps for type-1 diabetes mellitus: safety and efficacy. Expert Rev Med Devices (2020) 17(7):707–20. doi: 10.1080/17434440.2020.1784724

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Dovc K, Battelino T. Evolution of diabetes technology. Endocrinol Metab Clin North Am (2020) 49(1):1–18. doi: 10.1016/j.ecl.2019.10.009

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Beato-Víbora PI, Gallego-Gamero F, Ambrojo-López A, Gil-Poch E, Martín-Romo I, Arroyo-Díez FJ, et al. Amelioration of user experiences and glycaemic outcomes with an advanced hybrid closed loop system in a real-world clinical setting. Diabetes Res Clin Pract (2021) 178:108986. doi: 10.1016/j.diabres.2021.108986

PubMed Abstract | CrossRef Full Text | Google Scholar

31. Bally L, Thabit H, Kojzar H, Mader JK, Qerimi–Hyseni J, Hartnell S, et al. Day–and–night glycaemic control with closed–loop insulin delivery versus conventional insulin pump therapy in free–living adults with well controlled type 1 diabetes: an open–label, randomised, crossover study. Lancet Diabetes Endocrinol (2017) 5(4):2612–70. doi: 10.1016/S2213-8587(17)30001-3

CrossRef Full Text | Google Scholar

32. Ruan Y, Ball L, Thabit H, Leelarathna L, Hartnell S, Tauschmann M, et al. Hypoglycemia incidence and recovery during home use of hybrid closed–loop insulin delivery in adults with type 1. Diabetes Obes Metab (2018) 20(8):2004–8. doi: 10.1111/dom.13304

PubMed Abstract | CrossRef Full Text | Google Scholar

33. Boughton CK, Hovorka R. Is an artificial pancreas (closed-loop system) for type 1 diabetes effective? Diabetes Med (2019) 36(3):279–86. doi: 10.1111/dme.13816

CrossRef Full Text | Google Scholar

34. Bergenstal RM, Nimri R, Beck RW, Criego A, Laffel L, Schatz D, et al. A comparison of two hybrid closed-loop systems in adolescents and young adults with type 1 diabetes (FLAIR): A multicentre, randomised, crossover trial. Lancet (2021) 16(397):208–19. doi: 10.1016/S0140-6736(20)32514-9

CrossRef Full Text | Google Scholar

Keywords: type 1 diabetes, advanced hybrid closed-loop, patient report outcome measure (PRO), HbA1c, time in range

Citation: Gianini A, Suklan J, Skela-Savič B, Klemencic S, Battelino T, Dovc K and Bratina N (2022) Patient reported outcome measures in children and adolescents with type 1 diabetes using advanced hybrid closed loop insulin delivery. Front. Endocrinol. 13:967725. doi: 10.3389/fendo.2022.967725

Received: 13 June 2022; Accepted: 27 July 2022;
Published: 19 August 2022.

Edited by:

Ernesto Maddaloni, Faculty of Medicine and Dentistry, Sapienza University of Rome, Italy

Reviewed by:

Silvia Pieralice, Campus Bio-Medico University, Italy
Riccardo Schiaffini, Bambino Gesù Children’s Hospital (IRCCS), Italy

Copyright © 2022 Gianini, Suklan, Skela-Savič, Klemencic, Battelino, Dovc and Bratina. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Nataša Bratina, bmF0YXNhLmJyYXRpbmFAbWYudW5pLWxqLnNp

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.