ORIGINAL RESEARCH article
Front. Cardiovasc. Med. , 18 February 2025
Sec. Cardiovascular Surgery
Volume 12 - 2025 | https://doi.org/10.3389/fcvm.2025.1486375
Introduction: Since TAVR was approved for lower-risk aortic stenosis (AS) patients, managing post-implantation conduction disturbances has become crucial, especially with self-expanding heart valves (SEV). This study aims to identify risk factors for conduction disturbances in such patients using a specific fluoroscopic cusp overlap (COL) technique.
Methods: This retrospective study analyzed AS patients who underwent TAVR with SEV from 2019 to 2022, excluding those needing pacemakers or valve-in-valve procedures. Patients were grouped by conventional (CON) and COL techniques, with outcomes monitored using Valve Academic Research Consortium (VARC)-2 criteria.
Results: In this cohort study of 114 patients, 17 were excluded due to pre-existing pacemakers. Forty-seven received SEVs using COL, and 50 with CON techniques. The COL group showed a significant reduction in new LBBB (27.7% vs. 46%, p = 0.006) and PPI rates (4.3% vs. 18%, p = 0.033) compared to the CON group. Deeper implantation depth below the non-coronary cusp (NCC) and left coronary cusp (LCC) was linked to an increased risk of conduction disturbances. Multivariate analysis identified smaller left ventricular outflow tract diameter, shorter membranous septum length, and greater pre-releasing implantation depth below the LCC as predictors of future PPI risk.
Conclusion: The use of the COL technique significantly reduces the risk of newly developed conduction disturbances after SEV TAVR. Keeping SEV implantation depth within 1 mm of the membranous septum length and maintaining an implantation depth of <6 mm below the LCC before final release further minimizes the risk of PPI.
Since the approval of transcatheter aortic valve replacement (TAVR) for intermediate and low-risk aortic stenosis (AS) patients, lifetime management has become a significant concern, especially for younger and lower-risk individuals (1). One critical consideration in performing TAVR in these patients is the risk of conduction disturbances post-implantation, particularly with the use of self-expanding heart valves (SEVs) (2). Conduction disturbances following TAVR are associated with poor ventricular function recovery and increased hospitalizations years after the procedure (3, 4). These disturbances include new-onset LBBB and the need for permanent pacemaker implantation (PPI).
SEVs are associated with a higher risk of PPI compared to BEVs, primarily due to their longer stent frames and deeper implantation, which can disrupt the conduction system at the membranous septum. The use of right anterior oblique (RAO) fluoroscopic projection, known as the COL view, has been shown to reduce the incidence of PPI in patients undergoing SEV TAVR. Despite these advancements, a significant proportion of patients still require PPI after valve implantation. In the ATLAS registry, Kalogeras et al. reported a significantly lower PPI rate with the Evolut Pro™ compared to the Evolut R™ (5). However, data from the Society of Thoracic Surgeons (STS) registry (2014–2017) showed no significant difference in PPI rates across three generations of the CoreValve system (6). Recent findings on the Evolut FX suggest that PPI rates with this latest-generation valve are relatively low. These findings highlight ongoing uncertainty regarding whether advancements in device design alone are sufficient to reduce PPI rates (7). We propose that improvements in understanding the anatomy of the conduction system and optimizing implantation techniques, such as precise control of device depth, may also play a critical role in reducing PPI rates. This perspective underscores the need for further investigation and will be included in the introduction to provide a comprehensive background on PPI incidence following. This study aims to identify risk factors in AS patients undergoing SEV TAVR using the COL fluoroscopic projection in comparison to the conventional three-cusp (CON) view technique.
This cohort study is a retrospective analysis conducted from January 1, 2019, to January 31, 2022, with institutional review board approval. The study enrolled AS patients who underwent TAVR using SEVs. From January 2019 to December 2020, the Medtronic CoreValve Evolut R™ (Medtronic, Minneapolis, MN) was the most commonly used device and was implanted using the conventional three-cusp (CON) view technique (the CON group). From January 2021 to December 2022, the Medtronic Evolut PRO™ (Medtronic, Minneapolis, MN) was the most commonly used device and was implanted using the COL technique (the COL group). Patients who required a pacemaker before TAVR and those undergoing aortic valve-in-valve procedures were excluded.
Pre-operative, peri-operative, and post-operative characteristics and outcomes were recorded according to Valve Academic Research Consortium (VARC)-2 criteria (8) up to 30 days after TAVR. Electrocardiograms (EKGs) were analyzed for PR interval, QRS interval, P axis, QRS axis, R axis, and QTc pre-operatively, immediately after TAVR, and 1-week post-TAVR implantation.
On an EKG, left bundle branch block (LBBB) is identified by a QRS complex duration of 120 ms (ms) or more, indicating delayed ventricular depolarization due to a blockage in the left bundle branch. Morphologically, LBBB typically shows a broad, notched, or slurred R wave in Lead V1 (rS or RSr' pattern) and a similarly broad, notched, or slurred S wave in Lead V6. The lateral leads (I, aVL, V5, V6) also exhibit broad, notched, or slurred R waves with a delayed intrinsicoid deflection (R peak time ≥60 ms). Right bundle branch block (RBBB) is characterized by a prolonged QRS complex duration, typically exceeding 120 ms, indicating altered conduction through the right bundle branch, affecting the sequence and timing of ventricular depolarization. In Lead V1, RBBB often presents with a broad, slurred S wave (rsR' pattern), while Lead V6 shows a wide, notched R wave. These electrocardiographic characteristics indicate RBBB's impact on ventricular activation.
Severe Leaflet or Annular Calcification was defined by specific criteria assessed via computed tomography (CT) imaging, including an Agatston score of more than 2,000 for the aortic valve leaflets and annulus. Membranous Septum Length was assessed by multi-slice CT, which provides detailed cross-sectional views of the heart. This method allows for precise evaluation of the anatomical dimensions of the membranous septum in relation to surrounding cardiac structures. In the context of Minimizing Depth According to the Membranous Septum (MIDAS) (9), the membranous septum length is determined by identifying the thinnest part of the interventricular septum on the axial plane image, typically aligned with the tricuspid annulus (7). This approach is crucial for assessing the optimal depth for interventions involving the membranous septum, such as valve replacements or procedures impacting the heart's conduction system.
All patients in the cohort received general anesthesia for the TAVR procedure, performed under transesophageal echocardiography guidance. Transesophageal echocardiography was used to monitor for complications, assess valvular and paravalvular leakage, and evaluate post-procedure outcomes according to VARC-2 definitions.
The SEVs implanted starting from the virtual ring plane under the three-cusp view (10). The implanter adjusted the TAVR stent to maintain a position 3–6 mm below the lowest non-coronary cusp (NCC) inflow point by continuously adjusting the delivery catheter. Control pacing at a rate of 120 BPM was initiated when the second portion (node 2) CoreValve stent frame emerged from the capsule to the point of no return, after which the CoreValve was fully released. If the final valve position was not ideal, the valve was recaptured and repositioned to an appropriate depth. The final pre-releasing depths (PRD) of the NCC and left coronary cusp (LCC) were identified and recorded.
The valve was deployed at a higher position, from 1/2 to 1/3 of the diagnostic pigtail catheter at the nadir or NCC, using the fluoroscopic COL view (11). This view is achieved by adjusting the fluoroscopic angles so that the right coronary cusp (RCC) and LCC overlap, with the NCC centered between them, typically in a right anterior oblique (RAO) caudal position. After releasing the valve, it descends into the left ventricle and stops 1–6 mm below the annular virtual ring at the NCC side. At the point of no return, the C-arm fluoroscopy is rotated to the left anterior oblique (LAO) view with removal of parallax, aligning the fluoroscopic angles correctly to avoid visual distortion, making the aortic annulus appear as a perfect circle and the delivery catheter free of angular displacement. Root angiography is then performed. The valve is released when the entire stent is positioned below the annulus plane. If the desired depth is not achieved after root angiography, the valve is recaptured and redeployed at a higher or lower position. All angles and implantation depths below the annulus plane at different projections are recorded and compared.
Univariate analyses were conducted to compare demographic, procedural, and outcome parameters of patients undergoing SEV TAVR using different techniques. Continuous variables are presented as mean ± SD and were compared using either the Student's t-test or the Wilcoxon rank sum test. Categorical variables are expressed as counts and percentages and were compared using Pearson's chi-square test or Fisher's exact test, as appropriate. Clinical characteristics and laboratory measurements between the groups were compared using relevant statistical tests.
In multivariate analyses, independent predictors of conduction disturbances (both new LBBB and PPI) and PPI were identified, including device types and variables associated with conduction disturbances or PPI in univariate analyses. The Receiver Operating Characteristic (ROC) curve was used to assess the predictive performance of demographic and procedural parameters for PPI risk. The optimal cutoff point on the ROC curve was determined using Youden's index. A two-sided p-value of <0.05 was considered statistically significant for all analyses. Statistical calculations were performed using GraphPad Prism 10.0 software.
In this cohort study, 114 patients received either the Medtronic CoreValve Evolut R™ or the Medtronic Evolut PRO™. Seventeen patients (6 in the COL group and 11 in the CON group) were excluded from the study due to pre-existing pacemakers. Forty-seven patients received SEVs utilizing the COL technique (the COL group), and 50 patients received TAVR using the conventional three-cusp view technique (the CON group). The pre-operative, peri-operative, and post-operative patient demographics, electrocardiographic and CT measurements are shown in Table 1. Overall, the two groups were well matched, with no significant differences observed in baseline characteristics including demographic data and baseline electrocardiographic and CT measurements. However, there were more patients presented with heart failure and the measured left ventricular outflow tract (LVOT) area was significantly larger in the CON group. The length of the membranous septum, measured by either the coronal method or the MIDAS method, also showed no significant difference between the two groups (Table 1).
Table 1. Baseline characteristics, electrocardiographic and computed tomographic measurements of the patients in this study.
The technical details of the procedures and their outcomes are outlined in Table 2. TAVR procedures were predominantly conducted via transfemoral access. Transcarotid alternative access was used for SEV implantation in 4% of patients in the CON group and 10.6% of patients in the COL group. As mentioned, the Medtronic CoreValve Evolut R™ was more commonly used in the CON group, while the Medtronic Evolut PRO™ was more commonly used in the COL group. Additionally, the requirement for pre- and post-dilatation, and recapture/repositioning was similar in both groups (Table 2).
Table 2. Procedural characteristics, and procedural and clinical outcomes of the patients in this study.
In the CON group, 54% of the SEVs were successfully deployed using a top-down approach from either the annular (50%) or supra-annular plane (4%). However, in 46% of patients, the SEVs were successfully deployed using a bottom-up approach, pulling back from the LVOT for better positioning. In contrast, 87% of the SEVs in the COL group were successfully deployed using a top-down approach from either the annular (4.4%) or supra-annular plane (82.6%). Only 13% of patients needed a bottom-up approach for positioning. The differences in SEV deployment approaches were significantly different between the two groups.
The implantation depth below the NCC is considered to be associated with the PPI rate and the rate of newly developed conduction disturbances after TAVR. We examined and compared the implantation depths below the NCC and LCC before and after the final release of the SEV using the LAO view with the removal of the parallax and the COL view (Table 2; Figure 1). Our findings showed that the implantation depth below the NCC did not change significantly before and after the release of the SEVs (PRD vs. RD = 4.3 ± 1.8 mm vs. 3.9 ± 2.6 mm, p = NS in the CON group; PRD vs. RD = 3.4 ± 1.5 mm vs. 2.7 ± 2.0 mm, p = NS in the COL group). However, the COL technique resulted in a significant reduction in implantation depth below the NCC both before and after the final release (PRD: CON group vs. COL group = 4.3 ± 1.8 mm vs. 3.4 ± 1.5 mm, p = 0.007; RD: CON group vs. COL group = 3.9 ± 2.6 mm vs. 2.7 ± 2.0 mm, p = 0.021) (Table 2).
Figure 1. Measurements of implantation depth were taken in the left anterior oblique view with the removal of parallax. The implantation depths before and after final release were measured accordingly. In this particular case, a tilt of the Medtronic Evolut PRO™ with upward displacement was observed, changing from 4 mm to 2 mm on the NCC side and from 8 mm to 3 mm on the LCC side after the final release.
In contrast to the findings on the NCC side, the implantation depth below the LCC changed significantly after release. In the CON group, the depth decreased from 7.3 ± 2.8 mm in the PRD to 5.7 ± 2.3 mm after release (p < 0.0001). In the COL group, the depth decreased from 7.2 ± 2.8 mm in PRD to 4.7 ± 2.3 mm in the COL view, and to 4.6 ± 2.2 mm in the LAO parallax view (p < 0.0001). Additionally, the COL technique resulted in a significant reduction in implantation depth below the LCC after the final release (PRD: CON group vs. COL group = 7.3 ± 2.8 mm vs. 7.2 ± 2.8 mm, p = NS; RD: CON group vs. COL group = 5.7 ± 2.3 mm vs. 4.6 ± 2.2 mm, p = 0.018). These findings indicate that the SEV moved upwards significantly after release on the LCC side, while on the NCC side, there was a slight but insignificant upward displacement after the final release of the SEV. Moreover, the COL technique significantly decreases the implantation depths on both the NCC and LCC sides.
Comparisons between the membranous septum length and the implantation depth below NCC for the two deployment techniques revealed statistical significance. The pre-releasing membranous septum length minus the implantation depth below NCC was significantly shorter in the CON group compared to the COL group, regardless of whether the membranous septum length was measured using the coronal method or the MIDAS method (PRD: CON vs. COL = −0.4 ± 2.6 mm vs. 1.1 ± 2.6 mm, p = 0.006; RD: CON vs. COL = 0.1 ± 0.32 mm vs. 1.5 ± 2.8 mm, p = 0.002, by coronal method, and PRD: CON vs. COL = −2.3 ± 2.6 mm vs. −1.0 ± 2.5 mm, p = 0.017; RD: CON vs. COL = −1.8 ± 2.9 mm vs. −0.5 ± 2.6 mm, p = 0.046, by MIDAS method, respectively).
Patients in the CON group tended to have a higher incidence of moderate or greater paravalvular leakage after TAVR, although this difference did not reach statistical significance (CON group vs. COL group = 6.01% vs. 0%, p = 0.0881) Figure 2; Table 2; Supplementary Video 1.
Figure 2. Significantly reduced conduction disturbance rates in the COL group compared to the CON group after TAVR. The incidences of new permanent pacemaker (PPM) implantation, newly developed LBBB in the operating room (new LBBB@OR), newly developed LBBB 1 week after transcatheter aortic valve replacement (TAVR) (new LBBB@1W), and recovery of LBBB 1 week after TAVR were illustrated and compared between the conventional (CON) group and cusp-overlap (COL) group.
In terms of conduction disturbances, patients in the COL group demonstrated significantly lower rates of newly developed LBBB both in the operating room and 1 week post-TAVR (immediate LBBB after TAVR: CON vs. COL = 46% vs. 27.7%, p = 0.0062; and LBBB 1 week after TAVR: CON vs. COL = 26% vs. 8.7%, p = 0.027, respectively). Moreover, the PPI rates 1 week after TAVR were also significantly lower in the COL group compared to the CON group (4.3% vs. 18%, p = 0.0329). A proportion of patients who initially presented with LBBB in the operating room showed recovery after 1 week (43.5% in the CON group vs. 61.5% in the COL group, p = 0.137).
Predictors for newly developed LBBB and PPI were further analyzed using univariate and multivariate logistic regression. Independent predictors of newly developed LBBB, PPI, and both were identified using multivariate analyses. Variables with a p-value < 0.1 in the univariate analysis were included in the multivariate model (Table 3).
Table 3. Predictors of conduction disturbances and permanent pacemaker implantation in aortic stenosis patients undergoing self-expanding valve transcatheter aortic valve replacement using the cusp overlap technique.
Significantly, deeper pre-release and release implantation depths beneath the NCC and LCC were correlated with an increased risk of conduction disturbances. Multivariate analysis further identified the LVOT perimeter, membranous septum length measured via the coronal method, and pre-release implantation depth below the LCC as significant predictors of PPI. The receiver operating characteristic (ROC) curve, along with Youden's index, were utilized to establish optimal thresholds for predicting PPI following transcatheter aortic valve replacement (TAVR). It was determined that a pre-releasing LCC implantation depth greater than 6 mm (ROC area: 0.799, p = 0.0028, maximal Youden's index at depth >6.5 mm), a membranous septum length less than 5 mm measured by the coronal method (ROC area: 0.690, p = 0.0412, maximal Youden's index at length <4.85 mm), and a difference between coronally measured membranous septum length and implantation depth below the NCC of −1 mm (ROC area: 0.726, p = 0.016, maximal Youden's index at length ≤0.9 mm) were the optimal cutoff values for predicting PPI post-TAVR.
The main findings of our study are as follows: (1) higher implantation and less post-TAVR paravalvular leakage were achieved with the use of the COL technique and Evolut PRO™ valve compared to the CON technique and Evolut R™; (2) the pre-releasing and released membranous septum length minus the implantation depth below the NCC was significantly shorter in the CON group compared to the COL group; (3) in terms of conduction disturbances, patients in the COL group demonstrated significantly lower rates of newly developed LBBB and PPI compared to the CON group; (4) multivariate analysis identified LVOT perimeter, membranous septum length measured by the coronal method, and pre-releasing implantation depth below the LCC as significant predictors of PPI after TAVR.
Conduction system abnormalities are the most common complication following TAVR and are associated with increased morbidity and mortality, longer hospital stays, and higher costs of care (12). Key risk factors for conduction disturbances include pre-existing RBBB, the use of certain SEVs, and the depth of device implantation within the LVOT (1–4). In this cohort, pre-existing RBBB was present in 14.3% of the conventional group compared to 4.3% in the cusp overlap group (p = 0.167). Univariate and multivariate analyses did not identify pre-existing RBBB as a contributing factor, suggesting that implantation technique may have a greater impact than pre-existing conduction block (13). Strategies to minimize conduction system injury focus on reducing interaction between the transcatheter heart valve and the membranous and muscular septum of the LVOT, where conduction fibers are most superficial. The membranous septum, located at the junction of the NCC and RCC, varies significantly among individuals and can influence the risk of conduction disturbances. Recent outcomes after SEV TAVR have improved significantly with the adoption of the COL technique, which targets a 3 mm inflow implantation depth to optimize valve placement and reduce PPI rates (2–4, 14–16). In this study, we aimed to identify risk factors for patients undergoing SEV TAVR using the COL technique. Our findings demonstrate that higher implantation depths and reduced post-TAVR paravalvular leakage were achieved with the COL technique using the Evolut PRO™ valve compared to the CON technique with the Evolut R™ valve. Additionally, the COL group exhibited significantly lower rates of newly developed LBBB and PPI compared to the CON group. Multivariate analysis identified not only the well-recognized risk factors of final implantation depth and smaller LVOT diameter but also a membranous septum length of less than 5 mm (measured by the coronal method) and a pre-releasing implantation depth below the LCC greater than 6 mm as significant predictors of PPI after TAVR. The depth of implantation relative to the membranous septum length is a critical factor influencing the risk of PPI. Jilaihawi et al. (9) reported that deploying a transcatheter heart valve below the membranous septum increases PPI risk, with the risk rising significantly when the difference between membranous septum length and implantation depth is negative (−1.6 mm in patients requiring pacemakers vs. 0.6 mm in those who did not; p < 0.001). Consistent with previous studies, we observed that the membranous septum length minus the implantation depths below the NCC and LCC was significantly shorter in the CON group compared to the COL group, regardless of the measurement method (coronal or MIDAS) (17). Furthermore, we identified a membranous septum length of less than 5 mm and a difference between the coronally measured membranous septum length and the implantation depth below the NCC of less than −1 mm as significant predictors of PPI. Therefore, maintaining SEV implantation depth within 1 mm of the membranous septum, in addition to using the COL technique and targeting a depth of less than 3 mm below the NCC, may significantly reduce the risk of PPI following SEV TAVR.
As mentioned earlier, if the SEV is deployed below the membranous septum, there is a greater chance of interaction with the conduction system (17). Therefore, in contrast to the CON technique, we emphasize a top-down approach for deployment of the SEV, starting with the catheter marker band positioned at the mid-portion or lower third of the pigtail in the NCC. Once the capsule is retracted, the inflow of the nitinol frame advances across the annulus and is positioned 3 mm below. This maneuver avoids traumatic advancement of the SEV into the ventricle, which would necessitate subsequent maneuvers to retract the catheter and increase interaction of the flared end of the SEV and/or the nose cone of the delivery system with the membranous septum. This top-down deployment approach was successfully accomplished in 87% of patients using COL techniques in our series and is considered a critical aspect of SEV deployment.
It is noteworthy that, in addition to the conventionally recognized released implantation depth below the NCC and LCC, we identified that pre-releasing implantation depths below the NCC and LCC were also predictive of newly developed LBBB and PPI. This is particularly true for a pre-releasing LCC implantation depth greater than 6 mm, which can predict PPI risk after TAVR. By using the COL technique, valve displacement on the LCC side is minimized (Table 2). After valve release, LCC depth is no longer a determining factor for conduction system injury, as the correction effect of the COL technique during SEV TAVR minimizes this asymmetry. This occurs because, during deployment of the CoreValve Evolut system, the valve frame is often asymmetrical, with the LCC side typically deeper. This occurs because the CoreValve Evolut delivery system has two spines, causing the valve to tilt towards the NCC side and unfold in a fan shape towards the LCC side when it begins to release. Since the membranous septum may extend partially to the vicinity of the LCC and the His bundle pierces the membranous portion between the NCC and LCC, sometimes following a more posterior path (15), a deeply implanted stent frame on the LCC side can still compress the conduction tissue, leading to conduction disturbances. When the implantation depth on the NCC side is successfully reduced to an average of about 3 mm using the COL technique, the implantation depth of the valve on the LCC side becomes even more critical. It is recommended that, at 80% deployment, implanters should rotate the gantry to a LAO projection to visualize the LCC and ensure that the inflow is neither supra-annular nor more than 6 mm in depth. Once final positioning is confirmed, implanters may retract the left ventricular wire, centralize the nose cone, and slowly release the delivery catheter from the SEV by releasing the frame paddles. The newer iteration of the Medtronic Evolut system (Evolut FX™) may reduce device pivoting upon release and achieve more symmetric implantation depths on both the NCC and LCC when utilizing the COL technique (7).
The study has several limitations that should be acknowledged. Firstly, the relatively small sample size in both groups and the single-center nature of the study limit the generalizability of the findings. Consequently, caution should be exercised when interpreting the results, especially regarding comparisons between the two techniques. Secondly, this is a before-and-after observational study with inherent limitations, primarily selection and confounding biases. Additionally, the evolution of the heart team's experience and technical refinements over time may have contributed to improved outcomes. However, we have tried to mitigate these biases by recruiting consecutive patients undergoing SEV TAVR during a relatively short period of 3 years.
Therefore, we consider this study useful for assessing the effects of implantation technique changes over time. Furthermore, this study was focused on a particular kind of SEV (Medtronic Evolut system). Therefore, caution should be taken in extrapolating these results. The Medtronic Evolut R™ and Evolut Pro™ systems featured a sealing skirt and delivery sheath diameter. The delivery system, which incorporated two metal spines, demonstrated similar trackability and radial force as the self-expanding valve. According to our observations, these differences did not significantly affect the outcomes. However, the Evolut R™ and Pro™ systems were not widely available in most centers globally. The newer Evolut FX™ system, with a single metal spine, has been shown to have equivalent effectiveness when using the COL technique (17, 18). The use of other self-expanding systems, such as the Abbott Portico system, has yielded similar results. However, modifications were necessary due to changes in the radial force of the valve and the trackability of the delivery system (19). Future studies addressing these limitations, such as larger multicenter randomized controlled trials conducted over a shorter and more homogeneous time frame, are warranted to provide more definitive conclusions regarding the use of the COL technique in SEV TAVR.
The COL implantation technique is a safe and feasible modification to the SEV TAVR procedure (20). This study showed that using the COL technique significantly reduced the incidence of newly developed LBBB and PPI in SEV TAVR compared to the CON technique. Furthermore, our study recommends maintaining an implantation depth of less than 6 mm below the left coronary cusp (LCC) prior to final release to enhance the controlled ostial landing (COL) technique (Central Illustration). This approach may further reduce the risk of permanent pacemaker implantation (PPI).
Central Illustration. Using the cusp-overlap technique significantly reduces the risk of newly developed LBBB and permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR). Refining the technique by keeping the self-expanding valve implantation depth within 1 mm of the membranous septum and maintaining an implantation depth of less than 6 mm below the LCC before final release may further minimize the risk of PPI.
The datasets presented in this article are not readily available because the data has limited access by IRB. Requests to access the datasets should be directed toeW91bmd0X2xlZUB5YWhvby5jb20udHc=.
The studies involving humans were approved by Institutional review board at Cheng-Hsin General Hospital. The studies were conducted in accordance with the local legislation and institutional requirements. The ethics committee/institutional review board waived the requirement of written informed consent for participation from the participants or the participants' legal guardians/next of kin because this is a retrospective study.
YL: Conceptualization, Data curation, Formal Analysis, Investigation, Methodology, Software, Validation, Visualization, Writing – original draft, Writing – review & editing. TT: Investigation, Validation, Writing – review & editing. KL: Data curation, Writing – review & editing. HL: Data curation, Investigation, Writing – review & editing. CL: Data curation, Investigation, Writing – review & editing. MH: Investigation, Visualization, Writing – review & editing. WY: Supervision, Validation, Writing – original draft, Writing – review & editing. JW: Funding acquisition, Resources, Supervision, Validation, Writing – review & editing.
The author(s) declare that no financial support was received for the research, authorship, and/or publication of this article.
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
The handling editor MS-L declared a past co-authorship with the author YT-L.
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fcvm.2025.1486375/full#supplementary-material
TAVR, transcatheter aortic valve replacement; AS, aortic stenosis; SEV, self-expanding heart valve; LBBB, left bundle branch block; PPI, permanent pacemaker implantation; BEV, balloon expandable heart valve; RAO view, right anterior oblique view; LAO view, left anterior oblique view; LVOT, left ventricular outflow tract; MSCT, multi-slice computed tomography; RCC, right coronary cusp; LCC, left coronary cusp; COL view, cusp overlap view; CON view, conventional three cusp view; MIDAS, minimizing depth according to the membranous septum; PRD, pre-releasing depth; RD, released depth.
1. Russo G, Tang GHL, Sangiorgi G, Pedicino D, Enriquez-Sarano M, Maisano F, et al. Lifetime management of aortic stenosis: transcatheter versus surgical treatment for young and low-risk patients. Circ Cardiovasc Interv. (2022) 15(11):915–27. doi: 10.1161/CIRCINTERVENTIONS.122.012388
2. Sammour Y, Krishnaswamy A, Kumar A, Puri R, Tarakji KG, Bazarbashi N, et al. Incidence, predictors, and implications of permanent pacemaker requirement after transcatheter aortic valve replacement. JACC Cardiovasc Interv. (2021) 14(2):115–34. doi: 10.1016/j.jcin.2020.09.063
3. Dobson LE, Musa TA, Uddin A, Fairbairn TA, Bebb OJ, Swoboda PP, et al. The impact of trans-catheter aortic valve replacement induced left-bundle branch block on cardiac reverse remodeling. J Cardiovasc Magn Reson. (2016) 19(1):22. doi: 10.1186/s12968-017-0335-9
4. Nazif TM, Chen S, George I, Dizon JM, Hahn RT, Crowley A, et al. New-onset left bundle branch block after transcatheter aortic valve replacement is associated with adverse long-term clinical outcomes in intermediate-risk patients: an analysis from the PARTNER II trial. Eur Heart J. (2019) 40(27):2218–27. doi: 10.1093/eurheartj/ehz227
5. Kalogeras K, Ruparelia N, Kabir T, Jabbour R, Naganuma T, Vavuranakis M, et al. Comparison of the self-expanding evolut-PRO transcatheter aortic valve to its predecessor evolut-R in the real world multicenter ATLAS registry. Int J Cardiol. (2020) 310:120–5. doi: 10.1016/j.ijcard.2020.02.070
6. Forrest JK, Kaple RK, Tang GHL, Yakubov SJ, Nazif TM, Williams MR, et al. Three generations of self-expanding transcatheter aortic valves: a report from the STS/ACC TVT registry. JACC Cardiovasc Interv. (2020) 13(2):170–9. doi: 10.1016/j.jcin.2019.08.035
7. Zaid S, Attizzani GF, Krishnamoorthy P, Yoon SH, Palma Dallan LA, Chetcuti S, et al. First-in-human multicenter experience of the newest generation supra-annular self-expanding evolut FX TAVR system. JACC Cardiovasc Interv. (2023) 16(13):1626–35. doi: 10.1016/j.jcin.2023.05.004
8. Kappetein AP, Head SJ, Genereux P, Piazza N, van Mieghem NM, Blackstone EH, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the valve academic research consortium-2 consensus document (VARC-2). Eur J Cardiothorac Surg. (2012) 42(5):S45–60. doi: 10.1093/ejcts/ezs533
9. Jilaihawi H, Zhao Z, Du R, Staniloae C, Saric M, Neuburger PJ, et al. Minimizing permanent pacemaker following repositionable self-expanding transcatheter aortic valve replacement. JACC Cardiovasc Interv. (2019) 12(18):1796–807. doi: 10.1016/j.jcin.2019.05.056
10. Tzeng YH, Lee YT, Tsao TP, Lee KC, Huang KC, Hsiung MC, et al. Performance and short-term outcomes of three different transcatheter aortic valve replacement devices in patients with aortic stenosis: a single-center experience. J Chin Med Assoc. (2019) 82(11):827–34. doi: 10.1097/JCMA.0000000000000187
11. Tang GHL, Zaid S, Michev I, Ahmad H, Kaple R, Undemir C, et al. “Cusp-Overlap” view simplifies fluoroscopy-guided implantation of self-expanding valve in transcatheter aortic valve replacement. JACC Cardiovasc Interv. (2018) 11(16):1663–5. doi: 10.1016/j.jcin.2018.03.018
12. Muntane-Carol G, Okoh AS, Chen C, Nault I, Kassotis J, Mohammadi S, et al. Ambulatory electorcardiographic monitoring following minimalist transcatheter aortic valve replacement. JACC Cardiovasc Interv. (2021) 14(24):2711–22. doi: 10.1016/j.jcin.2021.08.039
13. Aljabbary TF, Komatsu I, Ochiai T, Fremes SE, Ali N, Burke L, et al. Cusp overlap method for self-expanding transcatheter aortic valve replacement. Catheter Cardiovasc Interv. (2024) 103(1):202–8. doi: 10.1002/ccd.30910
14. Auffret V, Puri R, Urena M, Chamandi C, Rodriguez-Gabella T, Philippon F, et al. Conduction disturbances after transcatheter aortic valve replacement: current status and future perspectives. Circulation. (2017) 136(11):1049–69. doi: 10.1161/CIRCULATIONAHA.117.028352
15. Chen YH, Chang HH, Liao TW, Leu HB, Chen IM, Chen PL, et al. Membranous septum length predicts conduction disturbances following transcatheter aortic valve replacement. J Thorac Cardiovasc Surg. (2022) 164(1):42–51.e2. doi: 10.1016/j.jtcvs.2020.07.072
16. Kawashima T, Sato F. Visualizing anatomical evidences on atrioventricular conduction system for TAVI. Int J Cardiol. (2014) 174(1):1–6. doi: 10.1016/j.ijcard.2014.04.003
17. Hioki H, Watanabe Y, Kozuma K, Ryuzaki T, Goto S, Inohara T, et al. Validation of reliability and predictivity of membrane septum length measurements for pacemaker need after transcatheter aortic valve replacement. Catheter Cardiovasc Interv. (2022) 100(5):868–76. doi: 10.1002/ccd.30377
18. Bajwa T, Attizzani GF, Gada H, Chetcuti SJ, Williams MR, Ahmed M, et al. Use and performance of the evolut FX transcatheter aortic valve system. Cardiovasc Revasc Med. (2024) 67:1–7. doi: 10.1016/j.carrev.2024.04.002
19. Wang X, Wong I, Bajoras V, Vanhaverbeke M, Nuyens P, Bieliauskas G, et al. Impact of implantation technique on conduction disturbances for TAVR with the self-expanding portico/navitor valve. Catheter Cardiovasc Interv. (2023) 101(2):431–41. doi: 10.1002/ccd.30517
Keywords: transcatheter aortic valve replacement, self-expanding valves, cusp overlap technique, conduction disturbances, permanent pacemaker implantation
Citation: Lee Y-T, Tsao T-P, Lee K-C, Lin H-C, Liu C-T, Hsiung M-C, Yin W-H and Wei J (2025) Predictors of permanent pacemaker requirement in aortic stenosis patients undergoing self-expanding valve transcatheter aortic valve replacement using the cusp overlap technique. Front. Cardiovasc. Med. 12:1486375. doi: 10.3389/fcvm.2025.1486375
Received: 4 September 2024; Accepted: 3 February 2025;
Published: 18 February 2025.
Edited by:
Mao-Shin Lin, National Taiwan University Hospital, TaiwanReviewed by:
Jimmy Hon, National University Health System, SingaporeCopyright: © 2025 Lee, Tsao, Lee, Lin, Liu, Hsiung, Yin and Wei. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Wei-Hsian Yin, eWlud2g4OEBnbWFpbC5jb20=
Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.
Research integrity at Frontiers
Learn more about the work of our research integrity team to safeguard the quality of each article we publish.