Comparison of branched, fenestrated, and parallel strategies for endovascular treatment of thoracoabdominal aortic pathologies involving visceral regions

\r\nXiaochen Ma,&#x;Xiaochen Ma1,†Zhishi Wu,&#x;Zhishi Wu1,†Guanglang Zhu,&#x;Guanglang Zhu2,†Mingjin GuoMingjin Guo3Yongxin LiYongxin Li3Junjun LiuJunjun Liu3Mingyuan LiuMingyuan Liu4Youjin LiYoujin Li5Bo YeBo Ye6Tao ChenTao Chen6Ming QiMing Qi7Hongyan XiaoHongyan Xiao7Zhaoxiang ZengZhaoxiang Zeng8Yudong Sun
Yudong Sun2*Rui Feng
Rui Feng8*Zaiping Jing
Zaiping Jing9*Jiaxuan Feng
\r\nJiaxuan Feng2*
  • 1Department of Vascular Surgery, Changhai Hospital, Navy Medical University, Shanghai, China
  • 2Department of Vascular Surgery, Ruijin Hospital, Affiliated to Medical School of Shanghai Jiaotong University, Shanghai, China
  • 3Department of Vascular Surgery, Affiliated Hospital of Qingdao University, Qingdao University, Shandong, China
  • 4Department of Vascular Surgery, Beijing Friendship Hospital, Capital Medical University, Beijing, China
  • 5Department of Cardiovascular Surgery, People’s Hospital of Ningxia Hui Autonomous Region, Yinchuan, China
  • 6The Department of Vascular & Hernia Surgery, Ganzhou People’s Hospital, Ganzhou, Jiangxi, China
  • 7Department of Vascular Surgery, Wuhan Asia Heart Hospital, Wuhan, Hubei, China
  • 8Department of Vascular Surgery, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
  • 9Department of Vascular Surgery, Shanghai Fourth People’s Hospital, School of Medicine, Tongji University, Shanghai, China

Purpose: To compare the long-term efficacy of the parallel stent graft (PSG), fenestrated stent graft (FSG), and branched stent graft (BSG) techniques to treat thoracoabdominal aortic pathologies.

Materials and methods: In total, 291 patients with thoracic aortic aneurysm (TAA) and dissection (TAD) involving visceral arteries who underwent PSG (n = 85; 15 TAA and 70 TAD), FSG (n = 107; 47 TAD and 60 TAA), or BSG (n = 99; 37 TAD and 62 TAA) were included from multiple centers from January 2015 to December 2022, and a total of 1,108 visceral aortic branches were reconstructed.

Results: The average reconstruction time of each visceral aortic branch for FSG, BSG, and PSG is 27.5 ± 12.1, 23.2 ± 11.9, and 18.8 ± 11.8 min, respectively (P < 0.01). The free-from-endoleak rate at the last follow-up for FSG, BSG, and PSG was 86.9%, 91.9%, and 60.0%, respectively. The last follow-up patency rate for FSG, BSG, and PSG was 85.0%, 91.9%, and 94.1%, respectively. The average reconstruction price of each visceral aortic branch for FSG, BSG, and PSG was 41.40 ± 3.22 thousand RMB, 41.84 ± 3.86 thousand RMB, and 42.35 ± 4.52 thousand RMB, respectively (P = 0.24).

Conclusion: To treat the aortic pathologies involving the visceral segment, BSG had a lower endoleak rate and higher branch patency rate when compared with the FSG and PSG techniques. The expense of BSG was comparable to the other two techniques.

1 Introduction

Thoracic and abdominal aortic pathologies involving abdominal visceral areas include thoracic and abdominal aortic aneurysm, visceral aortic pseudoaneurysm, and aortic dissection aneurysm with distal false lumen. For example, the incidence of aortic dissection aneurysm with distal false lumen is not low, especially in the follow-up period after type A dissection surgery (1).

Thoracic and abdominal aortic pathologies can be treated with open surgery, hybrid surgery, or endovascular therapy. Open repair remains the first-line therapy, particularly in patients with connective tissue disorders. However, these procedures are associated with high morbidity and mortality rates, even in centers of excellence. Open arch repairs after acute type A surgery are associated with a 9% 30-day mortality and a 15% stroke rate. Open repair of postdissection thoracic aortic aneurysm (TAA) is associated with early mortality (8.3%), spinal cord ischemia (SCI; 1.3%), stroke (2.9%), and dialysis (5%) risks. The early reported experience of the endovascular management of postdissection TAA is encouraging and has been associated with favorable early outcomes (2). Endovascular aneurysm repair proved to have lower early morbidity and mortality compared with open repair in prospective randomized trials (3). There are three main options for endovascular therapy: parallel stent graft (PSG), fenestrated stent graft (FSG), and branched stent graft (BSG) techniques. However, endovascular treatment remained a challenge because of the need to reconstruct the visceral branch arteries. Endovascular strategies such as PSG, FSG, and BSG techniques have been reported for years (26). There are studies that have reported results for respective strategies, but the comparison among the three strategies in thoracoabdominal aortic pathologies is still lacking.

To compare the long-term results of the three endovascular strategies, data from multiple centers were collected and analyzed. The long-term results, safety, and economic cost were compared among the three groups.

2 Materials and methods

2.1 Patient enrollment

This was a multicenter retrospective study from 10 centers. From January 2015 to December 2022, there were 291 patients with thoracoabdominal aortic aneurysm and dissection involving visceral regions who underwent PSG [n = 85, 15 TAA and 70 thoracic aortic dissection (TAD)], FSG (n = 107, 60 TAA and 47 TAD), and BSG (n = 99, 62 TAA and 37 TAD). A total of 1,108 visceral aortic branches (N = 1,108) were reconstructed. This study was approved by the ethics committee and obtained informed consent from all patients.

The inclusion criteria were as follows: (a) aortic pathologies including aneurysm, and aortic dissection, involving abdominal visceral areas; (b) maximal diameter of aortic aneurysm ≥5.5 cm; (c) patients with aortic dissections pending rupture or aortic growth of >1 cm per year or >0.5 cm per half a year; (d) received endovascular repair (EVAR).

The exclusion criteria were as follows: (a) open surgery and hybrid surgery; (b) the combination of two or three kinds of PSG, FSG, and BSG; (c) aortic pseudoaneurysm involving visceral arteries, which might be caused by mycotic or inflammatory lesions; (d) patients who were unable to provide informed consent or participate in long-term follow-up. Figure 1 provides an overview of the patient enrollment process.

Figure 1
www.frontiersin.org

Figure 1. Screening process. CA, celiac axis; SMA, superior mesenteric artery; LRA, left renal artery; RRA, right renal artery.

2.2 Surgical procedures

2.2.1 FSG

All patients were provided general anesthesia in the supine position. Their left brachial artery and bilateral femoral arteries were then exposed and the fenestration of the stent graft was customized on the table according to the preoperative computed tomography angiography (CTA) (7).

The constraint guidewire was sutured at 6 o’clock of the stent graft and then the stent graft was folded back into the delivery catheter.

After re-sheathing the FSG, the delivery catheter was introduced to the ideal location during the angiography. The stent graft was slowly deployed during angiography to make the fenestration align with the origin of the visceral arteries. The guidewire and catheter went through the fenestrations into the relevant visceral arteries one by one. Viabahn stent grafts (Gore, Newark, DE, USA) were delivered and deployed to bridge the branch arteries and the fenestrations.

2.2.2 BSG

The procedure details of BSG have been described in previous literature (8). The mini-cuff on the stent graft was made using a Viabahn stent graft (Gore, USA). Figure 2 shows the preoperative and postoperative CTA images of a patient as an example.

Figure 2
www.frontiersin.org

Figure 2. Preoperative and postoperative CTA images of a patient who underwent EVAR. (A) Preoperative CTA image of thoracoabdominal aortic aneurysms. (B) Intraoperative CTA image. (C) Final postoperative CTA image. (D) Follow-up CTA demonstrates satisfactory aortic remodeling without endoleaks. (E) A picture of BSG.

2.2.3 PSG

The procedure details of PSG have been described in previous literature from this team (9).

2.3 Measurement and follow-up

The operational difficulty of the repair was measured by the average time of reconstructing a single visceral aortic branch (T=totaltime/numberofbranches). The surgical cost was measured by the average price required for the reconstruction of a single visceral aortic branch [C=(totalcostaorticstentgraftcost)/ numberofbranches].

The postoperative follow-up protocol for the patients included in the study involved performing a CTA every 3 months during the first year after the operation. Subsequently, the patients underwent a CTA every half a year in the second year, and then annually in the following years. The evaluation of the CTA images was conducted by two experienced vascular surgeons who were responsible for assessing the various parameters and outcomes.

The primary focus of the evaluation was to identify any adverse events, including but not limited to death, endoleak (leakage of blood outside the stent graft), stent graft migration, organ ischemia (reduced blood flow to organs), spinal cord ischemia, aneurysm enlargement, and branch graft occlusion. These events were considered important indicators of the long-term success and safety of the EVAR.

2.4 Statistical analysis

Continuous variables were summarized as mean ± standard deviation. Skewed variables were summarized as median and range. The Kaplan–Meier analysis was employed to compare the follow-up for free from endoleak among the three different repair techniques. The data obtained from the study were analyzed using SPSS for Windows software (version 26.0.0.0, IBM Corporation, Armonk, NY, USA). A P-value <0.05 was considered significant.

3 Results

3.1 Patient demographics

In the study, a total of 291 patients who met the criteria from January 2015 to December 2022 were enrolled. Among these patients, 156 were diagnosed with aortic dissection. Out of these patients, 47 underwent FSG repair, 37 received BSG, and 70 received PSG repair. The remaining 137 patients were diagnosed with aortic aneurysm. Among these patients, 60 underwent FSG repair, 62 received BSG repair, and 15 received PSG repair. In terms of the number of aortic branches reconstructed, 235 patients had all four aortic branches reconstructed, while 56 patients had only three aortic branches reconstructed.

A summary of the patient demographics is presented in Table 1. There were no statistically significant differences in average ages among the FSG (66.77 ± 10.09), BSG (64.92 ± 9.26), and PSG groups (66.98 ± 9.02) (P1 = 0.17, P2 = 0.88, P3 = 0.14, P = 0.26 > 0.05). Similarly, there were no statistically significant differences in sex among the three groups (male: FSG: 91.59% vs. BSG: 85.86% vs. PSG: 88.24%, P1 = 0.20, P2 = 0.47, P3 = 0.61, P = 0.47 > 0.05). In addition, there were no significant differences between the groups in terms of risk factors associated with vascular diseases, including smoking history (FSG: 50.47% vs. BSG: 49.49% vs. PSG: 49.41%, P1 = 0.89, P2 = 0.89, P3 = 0.99, P = 0.99 > 0.05), hypertension (FSG: 74.77% vs. BSG: 80.81% vs. PSG: 76.47%, P1 = 0.30, P2 = 0.78, P3 = 0.49, P = 0.57 > 0.05), and diabetes mellitus (FSG: 19.63% vs. BSG: 21.21% vs. PSG:29.41%, P1 = 0.79, P2 = 0.11, P3 = 0.19, P = 0.24 > 0.05).

Table 1
www.frontiersin.org

Table 1. Summary of patient demographics.

3.2 In-hospital comparisons

The operational difficulty of the repair was assessed by measuring the average time required to reconstruct a single visceral artery branch. The results showed that FSG had the longest average time of 27.5 ± 12.1 min, followed by BSG with an average time of 23.2 ± 11.9 min, and PSG with the shortest average time of 18.8 ± 11.8 min (P < 0.01).

The surgical cost was evaluated by determining the average cost required for the reconstruction of a single visceral artery branch. The average reconstruction price of each visceral aortic branch for FSG, BSG, and PSG was 41.40 ± 3.22 thousand RMB, 41.84 ± 3.86 thousand RMB, and 42.35 ± 4.52 thousand RMB, respectively (P = 0.24 > 0.05). This shows that the expense of BSG was comparable to the other two techniques.

In all the included patients, there were no deaths in the three groups. The endoleakage rate discovered in final angiography during surgery for FSG, BSG, and PSG was 8.4%, 3.0%, and 29.4%, respectively. Five patients in the PSG group and two patients in the BSG group experienced stent graft migration. Furthermore, 15 patients in the FSG group, 4 patients in the PSG group, and 3 patients in the BSG group developed organ ischemia (kidney or spleen). One patient in the FSG group developed spinal cord ischemia. Four patients in the FSG group and 13 patients in the PSG group had an aneurysm enlargement due to endoleak. Finally, 21 patients in the FSG group, 7 patients in the PSG group, and 4 patients in the BSG group experienced branch graft occlusion.

3.3 Follow-up outcomes

The endoleakage rate and patency rate during the follow-up period were determined based on the last CTA. The average follow-up time for FSG, BSG, and PSG was 45.86 ± 26.32, 44.13 ± 26.71, and 43.31 ± 24.11, respectively (P1 = 0.63, P2 = 0.50, P3 = 0.83, P = 0.78 > 0.05). There was no difference in follow-up time among the groups. Figure 3 shows that the free-from-endoleak rate at follow-up for FSG, BSG, and PSG was 86.9%, 91.9%, and 60.0%, respectively. The follow-up patency rate for FSG, BSG, and PSG was 85.0%, 91.9%, and 94.1%, respectively. The results showed that BSG had the lowest endoleak rate and highest branch patency rate, indicating better long-term efficacy.

Figure 3
www.frontiersin.org

Figure 3. Follow-up for free-from-endoleak and patency rates. Kaplan–Meier analysis of follow-up for free-from-endoleak and patency rates among the three EVAR techniques. (A) Follow-up for free-from-endoleak rate. (B) Follow-up for patency rate.

During the follow-up period, three patients died in the PSG group and two of these died of aortic aneurysm rupture due to endoleak after endovascular surgery. Two patients died in the FSG group and one of these died of an aortic ulcer and infection. Three patients died in the BSG group and none of these died of aortic disease or complications. As for complications during follow-up, 14 patients had an endoleak, 1 patient had an aortic ulcer and infection, and 2 patients had stent graft occlusion in the FSG group. Furthermore, 8 patients had an endoleak in the BSG group, and 34 patients had an endoleak and 2 patients had aortic aneurysm rupture in the PSG group. No patients had their endovascular surgery transform into open surgery, but four patients had an endovascular secondary intervention in the PSG group compared with no endovascular secondary interventions in the FSG and BSG groups.

4 Discussion

Thoracic and abdominal aortic pathologies mainly include true aneurysm, dissection, and pseudoaneurysm of the thoracic and abdominal aorta. Among them, the incidence rate of thoracic aortic aneurysm is 5–10 per 100,000 person years (10), and the incidence rate of abdominal aortic aneurysm is approximately three times that of thoracic aortic aneurysm (11). The incidence of aortic dissection is estimated to be 5–30 cases per million people per year (10). Pseudoaneurysm of the thoracic and abdominal aorta is caused by infection, trauma, and iatrogenic factors, and mostly appears as a complication of true aneurysm and intracavitary dissection treatment.

Procedures to repair proximal aortic dissection have improved the survival rate of acute phase patients tremendously. The false lumen of aortic dissection can be diminished by open repair or thrombosis and obliterated after stent graft repair and true lumen remodeling thereafter (12, 13). Nevertheless, most of the distal intimal tears and false lumen would exist consistently without intervention, especially in the distending aorta (14) and abdominal aorta (15). Most patients with Stanford type A aortic dissection would live with a patent distal false lumen after open repair of the ascending aorta with a speed of processing pathology as fast as 1–3.7 mm per year (16). The false lumen would become a dissection aneurysm eventually and threaten patients’ lives. Chronic aortic dissection is the second reason for aortic aneurysm. Approximately 9% of Stanford type A aortic dissection patients need a second intervention for distal dissection aneurysm after the proximal procedure (14). As for Stanford type B aortic dissection after thoracic endovascular repair (TEVAR), the prevalence is 7.8% (14).

There is no level I data supporting a size threshold for the repair of TAAs. The decision to treat TAAs is based on the risk of rupture and complications against the risk of morbidity and mortality due to the intervention (17). A 2010 joint guideline on thoracic aortic disease suggested open repair for TAA at a threshold of 5.5 cm for patients without comorbidities with TAAs secondary to chronic dissection and EVAR for those with degenerative or secular aneurysms (18). The background was less developed endovascular techniques. As endovascular techniques have developed and showed promise in TAA treatment, we began to treat some chronic dissection patients with complications or at a threshold of 5.5 cm. Patient selection was largely based on the high risk of morbidity and mortality of open aortic repair with 95.2% (20/21) of patients categorized as Crawford I (4.8%, 1/21), II (33.3%, 7/21), III (52.3%, 11/21), and V (4.8%, 1/21) with high risk of open repair. One Crawford IV patient was 83 years old with chronic obstructive pulmonary disease (COPD) and cardiac inefficiency and was deemed a poor candidate for open aortic repair (9).

Open surgery repair has been recognized as the first means of treating thoracic and abdominal aortic lesions and was the gold standard (1921); however, it also causes severe complications and mortality. For example, evidence shows that perioperative mortality cases range from 5%–19% and the paraparesis rate is between 3.8% and 15.1%. Compared with open surgery, EVAR has the risk of stent graft occlusion and endoleak but it also has promising short-term and mid-term outcomes.

There are several procedures for treating aortic aneurysm. Open repair with prosthesis graft replacement of aneurysmal aorta was the first method of treating thoracic abdominal aortic aneurysm and pararenal aortic aneurysm and is also the gold standard (2023). However, this method needs a large incision to expose the aorta, the aorta is clamped for a long time, and there is inevitable ischemia of abdominal organs. In addition, there is a much higher risk of spinal cord ischemia due to direct damage of intercostal arteries. The mortality of open surgery is as high as 7%–17% (22) and is especially high for Crawford type Ⅱ thoracic abdominal aortic aneurysm (23). In our previous study, 95.2% (20/21) of the patients involved had a descending thoracic aorta and were deemed high-risk patients for open surgery. This is a very difficult technique and can only be applied in a small number of large and experienced centers. Older patients or patients with multiple comorbidities are deemed poor candidates for this technique.

The debranching procedure was initially used to treat TAA in 1999 (24). As a hybrid procedure that combined open repair and endovascular therapy, it was less invasive, reducing organ ischemia and causing fewer respiratory system complications. However, an abdominal opening under general anesthesia is also needed which is a great challenge for senior patients or those with a hostile abdomen.

Total endovascular therapy is an alternative for patients who are deemed poor candidates for open or hybrid procedures. The branched and fenestrated EVAR techniques have shown good safety and efficiency in treating pararenal AAs and some TAAs. However, there are very strict limitations for anatomic character and patients should be stringently selected by accurate preoperative CTA examination and measurement. The origin of branch arteries must be good for fenestrated EVAR to be positioned; the space of the true lumen must be sufficient for branch EVAR to expand and select the branch arteries. But for TAD with a narrow and sometimes circuitous true lumen compressed by a false lumen and a highly variable origin of branch arteries, the branched and fenestrated EVAR techniques are not a good choice. The minimum preoperative diameter of the true lumen was 12.3 ± 4.8 mm in our study. Furthermore, the long time required for customization of a branched EVAR stent graft is a disadvantage. They also remain costly (25) and may not be fit for urgent or semi-urgent patients.

The parallel stent graft technique is defined as putting two or more stent grafts in one lumen to supply several different arteries. It is first invented to bail out the miscovered renal artery in the EVAR procedure. After modification and improvement, this technique has been widely used in treating pararenal AAs and some TAAs. There are marked advantages such as easy to maneuver, availability of materials, and flexible adaptation. Thus, it can be easily used in medical centers with basic conditions. Several large volume studies have proved that the parallel stent graft technique showed safety and efficiency in treating pararenal AAs and some TAAs (26, 27).

The patency of the false lumen and distal intimal tears are independent risk factors for chronic dilation of aortic dissection (28, 29). The intimal tear acts as an inflow and maintains the patency of the false lumen. Sealing the proximal intimal tear can lower the pressure of the false lumen and induce thrombosis and eventually remodel the true lumen. TEVAR is widely used to treat acute aortic dissection and has proven efficient (30, 31). Even uncomplicated type B aortic dissection can benefit from TEVAR (32). It is a good alternative for chronic aortic dissection, especially in patients deemed poor open repair candidates, to seal the intimal tear with a stent graft. However, the visceral district of the aorta limits the use of standard endovascular therapy because of the difficulty in reconstructing branch arteries. Parallel stent grafts can bridge the true lumen and branch artery across the intimal tear and false lumen, sealing the intimal tear at the same time as reconstructing the branch artery.

The most common complications of the parallel stent technique are endoleaks and occlusion of branch stent. In our previous study, we used coil and glue to assist in sealing the intimal tear and inducing thrombosis of the false lumen. Any type I a or Ib or type III endoleak during digital subtraction angiography (DSA) was treated with a coil and glue in our study. In total, 28.6% (6/21) patients were detected to have a type I or III endoleak during DSA. All were treated with a coil or Onyx glue embolization in the gutter. Full thrombosis of the false lumen was achieved in most cases (85.7%, 18/21). Two cases did not achieve full thrombosis of the false lumen because of a type II endoleak. There was no lesion progression observed in any patients. Those with part thrombosis of false lumen had a consistent diameter of the total aorta and showed no expansion during follow-up. The maximum diameter of the total aorta at follow-up showed a shrinking trend.

As to length of overlap between the branch stent graft and the main body, some specialists suggest as long as 5 instead of 2 cm to reduce endoleaks. In our experience, a 2–3 cm overlap is enough and no type Ⅱ endoleak was seen in the TAD. For TAD, the aims are to seal the tears and diminish the inflow and outflow of the false lumen with the branch arteries being validly reconstructed. Concepts such as a neck aneurysm and sufficient anchoring zone are not the same as a degenerative aortic aneurysm. As to the length of stenting in the branch arteries, 4–5 cm is preferred because stent grafts in a large aneurysm sac can swing and migrate with the heartbeat. If there is not enough landing zone, for example if the renal artery trunk is 2 cm only, a bare metal stent can be placed in advance to extend the anchor zone.

Acute occlusions of the branch stents are mostly due to mechanical reasons such as compression or kinks that lead to severe blood flow reduction. Our experience is to expand the balloon sufficiently and line the bare metal stent in the parallel stent graft aggressively if a kink or stenosis exists after balloon expansion. Bare stents were used (37.9%, n = 25) where necessary. In our previous study, a heparin banded weaved stent graft, Viabahn (Gore), was primarily chosen over (60, 90.9%) a laser-engraved cover stent such as Fluency (BARD, New Providence, NJ, USA) (6, 9.1%) for the flexibility and long enough length to avoid acute thrombosis and kinking. Furthermore, the main body of the Excluder (Gore) is much more flexible due to the continuous little wave weaved structure and can avoid compression in the parallel stent graft. One of our patients suffered from acute loss of their right kidney postoperatively. Emergency angiography confirmed thrombosis and a narrow renal stent graft. It was treated by catheter-directed thrombolysis and a bare metal stent was lined in the stenosis. One patient with occlusion of branch stent graft of renal arteries was seen in the follow-up period. There was moderate atherosclerosis in the run-off. No patient needed permanent hemodialysis though. The hyperplasia of the anastomosis may have contributed to the later restenosis and occlusion of the branch artery. We may see it in follow-up over a longer duration.

Another problem is ischemia of organs and the spinal cord due to long segment covering of the aorta. The reintervention of aortic dissection may face the challenge of covering almost all the intercostal arteries and lumbar arteries. Spinal cord ischemia is theoretically possible and was observed in one patient in our study. It may be because slow and gradual thrombosis occlusion instead of direct diminishing of the false lumen provides enough time for collateral circulation of intercostal arteries to establish. We tried our best to reserve the left subclavian artery and at least one side of the internal iliac arteries to protect the collateral circulation blood supply of the spinal cord. Another reason may be the small gutter at the landing zone and between parallel stent grafts could provide some blood supply for a period long enough for collateral circulation of the intercostal arteries to establish. Maintaining moderately high blood pressure and sufficient blood volume preoperatively are also important for spinal cord perfusion. Because of small number in our sample, we cannot give a solid conclusion.

The fenestrated stent graft technology includes in vivo in situ fenestration and in vitro pre-fenestration, and is mainly used to treat aortic arch diseases (33, 34). It can also be used to bridge branch stents on the basis of fenestration to provide blood supply to thoracic and abdominal aortic branch vessels, mostly for distal dissection. The problem with in situ fenestrated stent graft technology mainly lies in the changes and covering in the stent during the fenestrating process, which may cause potential damage to the graft and patients, such as ischemia caused by prolonged fenestrated time and iatrogenic complications caused by an improper fenestration operation. Therefore, it is mostly suitable for emergency surgery. Pre-fenestrated stent graft technology mainly includes customizing fenestration from manufacturers after measuring the patient's aortic data and fenestration on the operating table by the physician, but the difficulty lies in the accuracy of stent release, which needs high technical requirements.

In our study, we compared the endoleak rate and branch patency rate of three kinds of EVAR techniques, FSG, BSG, and PSG, in a sample of 291 patients during perioperation. In different case reports, due to differences in sample size, physician technical level, and stent production companies, there exist differences in the endoleak rate and branch patency rate of the three techniques, but the overall trend is consistent with our study (3538). Based on the scope of application, technical difficulty, short-term and long-term complications, and patient prognosis of the three technologies for aortic pathologies, we consider the parallel stent graft technology to have an endoleak problem that is difficult to solve. There exists technical barriers and durability issues with fenestrated stent graft technology, making it difficult to operate. Branched stent graft technology, as a technology with a wide range of applications, moderate technical difficulty, relatively few complications, and relatively good patient prognosis, can achieve good therapeutic effects and is the future development direction.

5 Limitations

The study only focused on evaluating the operational difficulty, surgical cost, and long-term efficacy without considering other important factors such as patient’s quality of life and potential complications associated with each repair method. Therefore, a more comprehensive analysis is needed to fully understand the benefits and drawbacks of each approach. While this study provides some insights into the three EVAR methods, it has several limitations that should be taken into consideration. Further research with larger sample sizes, longer follow-up periods, and comprehensive evaluations is needed to fully understand the efficacy and safety of these repair methods for aortic dissection and aortic aneurysm.

6 Conclusions

In conclusion, based on the limited data available, to treat the aortic pathologies involving visceral segment, BSG had a lower endoleak rate and higher branch patency rate when compared with the FSG and PSG techniques. It offers a balance between ease of use and cost. However, it is important to note that further research with larger sample sizes and longer follow-up periods is needed to fully evaluate the efficacy and safety of these repair methods.

Data availability statement

The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding authors.

Author contributions

XM: Writing – original draft, Writing – review & editing, Conceptualization, Data curation, Formal Analysis, Investigation, Methodology, Project administration, Software, Supervision, Validation, Visualization. ZW: Writing – original draft, Writing – review & editing, Data curation, Formal Analysis, Supervision. GZ: Data curation, Formal Analysis, Supervision, Writing – original draft, Writing – review & editing. MG: Software, Supervision, Writing – review & editing. YonL: Resources, Software, Supervision, Writing – review & editing. JL: Data curation, Writing – review & editing. ML: Data curation, Funding acquisition, Writing – review & editing. YouL: Data curation, Writing – review & editing. BY: Data curation, Writing – review & editing. TC: Data curation, Writing – review & editing. MQ: Data curation, Writing – review & editing. HX: Data curation, Writing – review & editing. ZZ: Data curation, Writing – review & editing. YS: Supervision, Writing – review & editing. RF: Supervision, Writing – review & editing. ZJ: Supervision, Writing – review & editing. JF: Formal Analysis, Funding acquisition, Investigation, Methodology, Supervision, Writing – original draft, Writing – review & editing.

Funding

The authors declare financial support was received for the research, authorship, and/or publication of this article. This study received support from the Natural Science Fund of China (No. 81970208), Shanghai Shenkang Frontier Technology Joint Research Project (No. SHDC12020115), Shanghai Education Commission Project (2021科技科创-03-163), Capital’s Funds for Health Improvement and Research (CFH 2022-4-20217), Beijing Nova Program (No.20230484308), Young Elite Scientists Sponsorship Program by CAST (2023QNRC001), Youth Elite Program of Beijing Friendship Hospital (YYQCJH2022-9), Science and Technology Program of Beijing Tongzhou District (KJ2023CX012), and Shanghai ShenKang Municipal Hospital's Joint Initiative on Emerging Cutting-Edge Technologies (SHDC120221).

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Zeng Z, Zhao Y, Wu M, Bao X, Li T, Feng J, et al. False lumen stent-grafts for repair of postdissection aortic aneurysms. J Vasc Interv Radiol. (2021) 32(5):703–11. doi: 10.1016/j.jvir.2021.01.280

PubMed Abstract | Crossref Full Text | Google Scholar

2. Spear R, Hertault A, Van Calster K, Settembre N, Delloye M, Azzaoui R, et al. Complex endovascular repair of postdissection arch and thoracoabdominal aneurysms. J Vasc Surg. (2018) 67(3):685–93. doi: 10.1016/j.jvs.2017.09.010

PubMed Abstract | Crossref Full Text | Google Scholar

3. Amiot S, Haulon S, Becquemin JP, Magnan PE, Lermusiaux P, Goueffic Y, et al. Fenestrated endovascular grafting: the French multicentre experience. Eur J Vasc Endovasc Surg. (2010) 39(5):537–44. doi: 10.1016/j.ejvs.2009.12.008

PubMed Abstract | Crossref Full Text | Google Scholar

4. Lobato AC, Camacho-Lobato L. Endovascular treatment of complex aortic aneurysms using the sandwich technique. J Endovasc Ther. (2012) 19(6):691–706. doi: 10.1583/JEVT-12-4023R.1

PubMed Abstract | Crossref Full Text | Google Scholar

5. Greenberg R, Eagleton M, Mastracci T. Branched endografts for thoracoabdominal aneurysms. J Thorac Cardiov Surg. (2010) 140(6 Suppl):S171–8. doi: 10.1016/j.jtcvs.2010.07.061

PubMed Abstract | Crossref Full Text | Google Scholar

6. Silveira PG, Galego GN, Bortoluzzi CT, Franklin RN. RE: “branched grafts for thoracoabdominal aneurysms: off-label use of FDA-approved devices”. J Endovasc Ther. (2012) 19(1):130. doi: 10.1583/11-3773.1

PubMed Abstract | Crossref Full Text | Google Scholar

7. Kuo HS, Huang JH, Chen JS. Handmade fenestrated stent grafts to preserve all supra-aortic branches in thoracic endovascular aortic repair. J Thorac Cardiov Surg. (2020) 160(3):629–39. doi: 10.1016/j.jtcvs.2019.07.096

PubMed Abstract | Crossref Full Text | Google Scholar

8. Zeng Z, Zhao Y, Ainiwaer A, Wu M, Bao X, Li T, et al. Physician-modified branched double-trunk stent-graft (PBDS) for thoracoabdominal aortic aneurysm. Heart Lung Circ. (2021) 30(6):896–901. doi: 10.1016/j.hlc.2020.10.022

PubMed Abstract | Crossref Full Text | Google Scholar

9. Liu J, Li Z, Feng J, Zhou J, Zhao Z, Bao X, et al. Total endovascular repair with parallel stent-grafts for postdissection thoracoabdominal aneurysm after prior proximal repair. J Endovasc Ther. (2019) 26(5):668–75. doi: 10.1177/1526602819863779

PubMed Abstract | Crossref Full Text | Google Scholar

10. Isselbacher EM, Preventza O, Hamilton BIJ, Augoustides JG, Beck AW, Bolen MA, et al. 2022 ACC/AHA guideline for the diagnosis and management of aortic disease: a report of the American Heart Association/American College of Cardiology joint committee on clinical practice guidelines. J Am Coll Cardiol. (2022) 80(24):e223–393. doi: 10.1016/j.jacc.2022.08.004

PubMed Abstract | Crossref Full Text | Google Scholar

11. Lu H, Du W, Ren L, Hamblin MH, Becker RC, Chen YE, et al. Vascular smooth muscle cells in aortic aneurysm: from genetics to mechanisms. J Am Heart Assoc. (2021) 10(24):e23601. doi: 10.1161/JAHA.121.023601

PubMed Abstract | Crossref Full Text | Google Scholar

12. Tolenaar JL, Kern JA, Jonker FH, Cherry KJ, Tracci MC, Angle JF, et al. Predictors of false lumen thrombosis in type B aortic dissection treated with TEVAR. Ann Cardiothorac Surg. (2014) 3(3):255–63. doi: 10.3978/j.issn.2225-319X.2014.05.17

PubMed Abstract | Crossref Full Text | Google Scholar

13. Kim KM, Donayre CE, Reynolds TS, Kopchok GE, Walot I, Chauvapun JP, et al. Aortic remodeling, volumetric analysis, and clinical outcomes of endoluminal exclusion of acute complicated type B thoracic aortic dissections. J Vasc Surg. (2011) 54(2):316–24; 324–5. doi: 10.1016/j.jvs.2010.11.134

PubMed Abstract | Crossref Full Text | Google Scholar

14. Thrumurthy SG, Karthikesalingam A, Patterson BO, Holt PJ, Hinchliffe RJ, Loftus IM, et al. A systematic review of mid-term outcomes of thoracic endovascular repair (TEVAR) of chronic type B aortic dissection. Eur J Vasc Endovasc Surg. (2011) 42(5):632–47. doi: 10.1016/j.ejvs.2011.08.009

PubMed Abstract | Crossref Full Text | Google Scholar

15. Ruddy JM, Reisenman P, Priestley J, Brewster LP, Duwayri Y, Veeraswamy RK. Stent graft therapy for false lumen aneurysmal degeneration in established type B aortic dissection (FADED) results in differential volumetric remodeling of the thoracic versus abdominal aortic segments. Ann Vasc Surg. (2014) 28(7):1602–9. doi: 10.1016/j.avsg.2014.02.009

PubMed Abstract | Crossref Full Text | Google Scholar

16. Fattori R, Bacchi-Reggiani L, Bertaccini P, Napoli G, Fusco F, Longo M, et al. Evolution of aortic dissection after surgical repair. Am J Cardiol. (2000) 86(8):868–72. doi: 10.1016/S0002-9149(00)01108-5

PubMed Abstract | Crossref Full Text | Google Scholar

17. Chaikof EL, Blankensteijn JD, Harris PL, White GH, Zarins CK, Bernhard VM, et al. Reporting standards for endovascular aortic aneurysm repair. J Vasc Surg. (2002) 35(5):1048–60. doi: 10.1067/mva.2002.123763

PubMed Abstract | Crossref Full Text | Google Scholar

18. Hiratzka LF, Bakris GL, Beckman JA, Bersin RM, Carr VF, Casey DJ, et al. 2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM guidelines for the diagnosis and management of patients with thoracic aortic disease. A report of the American College of Cardiology foundation/American Heart Association task force on practice guidelines, American Association for Thoracic Surgery, American College of Radiology, American Stroke Association, Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Interventional Radiology, Society of Thoracic Surgeons, and Society for Vascular Medicine. J Am Coll Cardiol. (2010) 55(14):e27–129. doi: 10.1016/j.jacc.2010.02.015

PubMed Abstract | Crossref Full Text | Google Scholar

19. Murana G, Castrovinci S, Kloppenburg G, Yousif A, Kelder H, Schepens M, et al. Open thoracoabdominal aortic aneurysm repair in the modern era: results from a 20-year single-centre experience. Eur J Cardiothorac Surg. (2016) 49(5):1374–81. doi: 10.1093/ejcts/ezv415

PubMed Abstract | Crossref Full Text | Google Scholar

20. Coselli JS. Update on repairs of the thoracoabdominal aorta. Tex Heart Inst J. (2013) 40(5):572–4.24391325

PubMed Abstract | Google Scholar

21. Coselli JS, LeMaire SA, Preventza O, de la Cruz KI, Cooley DA, Price MD, et al. Outcomes of 3309 thoracoabdominal aortic aneurysm repairs. J Thorac Cardiovasc Surg. (2016) 151(5):1323–37. doi: 10.1016/j.jtcvs.2015.12.050

PubMed Abstract | Crossref Full Text | Google Scholar

22. Coselli JS, Conklin LD, LeMaire SA. Thoracoabdominal aortic aneurysm repair: review and update of current strategies. Ann Thorac Surg. (2002) 74(5):S1881–4; discussion S1892–8. doi: 10.1016/S0003-4975(02)04139-5

PubMed Abstract | Crossref Full Text | Google Scholar

23. Coselli JS, Bozinovski J, LeMaire SA. Open surgical repair of 2286 thoracoabdominal aortic aneurysms. Ann Thorac Surg. (2007) 83(2):S862–4; discussion S890–2. doi: 10.1016/j.athoracsur.2006.10.088

PubMed Abstract | Crossref Full Text | Google Scholar

24. Quinones-Baldrich WJ, Panetta TF, Vescera CL, Kashyap VS. Repair of type IV thoracoabdominal aneurysm with a combined endovascular and surgical approach. J Vasc Surg. (1999) 30(3):555–60. doi: 10.1016/S0741-5214(99)70084-4

PubMed Abstract | Crossref Full Text | Google Scholar

25. Dias NV, Resch TA, Sonesson B, Ivancev K, Malina M. EVAR of aortoiliac aneurysms with branched stent-grafts. Eur J Vasc Endovasc Surg. (2008) 35(6):677–84. doi: 10.1016/j.ejvs.2007.10.022

PubMed Abstract | Crossref Full Text | Google Scholar

26. Donas KP, Torsello GB, Piccoli G, Pitoulias GA, Torsello GF, Bisdas T, et al. The PROTAGORAS study to evaluate the performance of the endurant stent graft for patients with pararenal pathologic processes treated by the chimney/snorkel endovascular technique. J Vasc Surg. (2016) 63(1):1–7. doi: 10.1016/j.jvs.2015.07.080

PubMed Abstract | Crossref Full Text | Google Scholar

27. Donas KP, Lee JT, Lachat M, Torsello G, Veith FJ. Collected world experience about the performance of the snorkel/chimney endovascular technique in the treatment of complex aortic pathologies: the PERICLES registry. Ann Surg. (2015) 262(3):546–53; 552–3. doi: 10.1097/SLA.0000000000001405

PubMed Abstract | Crossref Full Text | Google Scholar

28. Kunishige H, Myojin K, Ishibashi Y, Ishii K, Kawasaki M, Oka J. Predictors of surgical indications for acute type B aortic dissection based on enlargement of aortic diameter during the chronic phase. Jpn J Thorac Cardiovasc Surg. (2006) 54(11):477–82. doi: 10.1007/s11748-006-0039-9

PubMed Abstract | Crossref Full Text | Google Scholar

29. Akutsu K, Nejima J, Kiuchi K, Sasaki K, Ochi M, Tanaka K, et al. Effects of the patent false lumen on the long-term outcome of type B acute aortic dissection. Eur J Cardiothorac Surg. (2004) 26(2):359–66. doi: 10.1016/j.ejcts.2004.03.026

PubMed Abstract | Crossref Full Text | Google Scholar

30. Nienaber CA, Fattori R, Lund G, Dieckmann C, Wolf W, von Kodolitsch Y, et al. Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement. New Engl J Med. (1999) 340(20):1539–45. doi: 10.1056/NEJM199905203402003

PubMed Abstract | Crossref Full Text | Google Scholar

31. Dake MD, Kato N, Mitchell RS, Semba CP, Razavi MK, Shimono T, et al. Endovascular stent-graft placement for the treatment of acute aortic dissection. New Engl J Med. (1999) 340(20):1546–52. doi: 10.1056/NEJM199905203402004

PubMed Abstract | Crossref Full Text | Google Scholar

32. Nienaber CA, Kische S, Rousseau H, Eggebrecht H, Rehders TC, Kundt G, et al. Endovascular repair of type B aortic dissection: long-term results of the randomized investigation of stent grafts in aortic dissection trial. Circ Cardiovasc Interv. (2013) 6(4):407–16. doi: 10.1161/CIRCINTERVENTIONS.113.000463

PubMed Abstract | Crossref Full Text | Google Scholar

33. Shang T, Tian L, Li DL, Wu ZH, Zhang HK. Favourable outcomes of endovascular total aortic arch repair via needle based in situ fenestration at a mean follow-up of 5.4 months. Eur J Vasc Endovasc Surg. (2018) 55(3):369–76. doi: 10.1016/j.ejvs.2017.11.022

PubMed Abstract | Crossref Full Text | Google Scholar

34. Liu W, Wang B, Cui C. In situ fenestration combined with in vitro pre-fenestration techniques for treating multiple aortic aneurysms. Asian J Surg. (2023) 46(9):4094–5. doi: 10.1016/j.asjsur.2023.04.075

PubMed Abstract | Crossref Full Text | Google Scholar

35. Eagleton MJ, Follansbee M, Wolski K, Mastracci T, Kuramochi Y. Fenestrated and branched endovascular aneurysm repair outcomes for type II and III thoracoabdominal aortic aneurysms. J Vasc Surg. (2016) 63(4):930–42. doi: 10.1016/j.jvs.2015.10.095

PubMed Abstract | Crossref Full Text | Google Scholar

36. Dossabhoy SS, Simons JP, Diamond KR, Flahive JM, Aiello FA, Arous EJ, et al. Reinterventions after fenestrated or branched endovascular aortic aneurysm repair. J Vasc Surg. (2018) 68(3):669–81. doi: 10.1016/j.jvs.2017.12.036

PubMed Abstract | Crossref Full Text | Google Scholar

37. Kanaoka Y, Ohki T. Midterm results of endovascular treatment for the patients with thoracoabdominal aortic aneurysms. Ann Vasc Dis. (2019) 12(2):163–70. doi: 10.3400/avd.ra.19-00039

PubMed Abstract | Crossref Full Text | Google Scholar

38. Lepidi S, Piazza M, Scrivere P, Menegolo M, Antonello M, Grego F, et al. Parallel endografts in the treatment of distal aortic and common iliac aneurysms. Eur J Vasc Endovasc Surg. (2014) 48(1):29–37. doi: 10.1016/j.ejvs.2014.03.017

PubMed Abstract | Crossref Full Text | Google Scholar

Keywords: aortic aneurysm, aortic dissection, endovascular repair, visceral arteries, branched stent graft, parallel stent graft, fenestrated stent graft

Citation: Ma X, Wu Z, Zhu G, Guo M, Li Y, Liu J, Liu M, Li Y, Ye B, Chen T, Qi M, Xiao H, Zeng Z, Sun Y, Feng R, Jing Z and Feng J (2024) Comparison of branched, fenestrated, and parallel strategies for endovascular treatment of thoracoabdominal aortic pathologies involving visceral regions. Front. Cardiovasc. Med. 11:1416635. doi: 10.3389/fcvm.2024.1416635

Received: 12 April 2024; Accepted: 26 August 2024;
Published: 24 September 2024.

Edited by:

Tharmarajan Ramprasath, Georgia State University, United States

Reviewed by:

Senthamizharasi Manivasagam, The University of Iowa, United States
Baolei Guo, Fudan University, China
Yonghui Qiao, Northwestern Polytechnical University, China

Copyright: © 2024 Ma, Wu, Zhu, Guo, Li, Liu, Liu, Li, Ye, Chen, Qi, Xiao, Zeng, Sun, Feng, Jing and Feng. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Yudong Sun, c3VueXVkb25nQHNtbXUuZWR1LmNu; Rui Feng, d2VibWFzdGVyQHh1ZWd1YW4ubmV0; Zaiping Jing, SmluZ3phaXBpbmdAMTI2LmNvbQ==; Jiaxuan Feng, ZmVuZ2ppYXh1YW4wMUAxNjMuY29t

These authors have contributed equally to this work

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.