Skip to main content

CORRECTION article

Front. Cardiovasc. Med., 20 July 2022
Sec. Cardiovascular Imaging

Corrigendum: Quantitative evaluation of post-stenotic blood flow disturbance in canine femoral artery stenosis model: An early experience with vector flow imaging

  • 1Department of Ultrasound, Peking University International Hospital, Beijing, China
  • 2Department of Ultrasound, The Fourth Medical Center of PLA General Hospital, Beijing, China
  • 3Shenzhen Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China
  • 4Department of Vascular Surgery, Austin Hospital, University of Melbourne, Melbourne, VIC, Australia

A corrigendum on
Quantitative Evaluation of Post-stenotic Blood Flow Disturbance in Canine Femoral Artery Stenosis Model: An Early Experience With Vector Flow Imaging

by Zhao, R., Zheng, H., Wang, W., Du, Y., Tong, Y., and Wen, C. (2022). Front. Cardiovasc. Med. 9:829825. doi: 10.3389/fcvm.2022.829825

In the published article, there was an error in the Section Materials and Methods, subsection “V Flow Ultrasound Assessment of Canine Femoral Artery.” The equation for the Tur index calculation used by the ultrasound system was incorrectly displayed as:

Tur=(1C2S2N)×100%

The corrected equation appears below:

Tur=(1C2+S2N)×100%

The authors apologize for this error and state that this does not change the scientific conclusions of the article in any way. The original article has been updated.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Keywords: arterial stenosis, Doppler, duplex ultrasound, femoral artery, post-stenotic turbulence, vector flow imaging

Citation: Zhao R, Zheng H, Wang W, Du Y, Tong Y and Wen C (2022) Corrigendum: Quantitative evaluation of post-stenotic blood flow disturbance in canine femoral artery stenosis model: An early experience with vector flow imaging. Front. Cardiovasc. Med. 9:979992. doi: 10.3389/fcvm.2022.979992

Received: 28 June 2022; Accepted: 07 July 2022;
Published: 20 July 2022.

Edited and reviewed by: Himadri Chattopadhyay, Jadavpur University, India

Copyright © 2022 Zhao, Zheng, Wang, Du, Tong and Wen. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Chaoyang Wen, wenchaoyang@pkuih.edu.cn; Yisha Tong, yisha.tong@austin.org.au

These authors have contributed equally to this work

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.