- 1Department of Cardiology, Hospital Álvaro Cunqueiro, University Hospital of Vigo, Vigo, Spain
- 2Cardiovascular Research Group, Galicia Sur Health Research Institute (IIS Galicia Sur), Vigo, Spain
Since its conception, transcatheter aortic valve implantation (TAVI) has undergone important improvements both in the implantation technique and in transcatheter devices, allowing an enthusiastic adoption of this therapeutic approach in a wide population of patients previously without a surgical option and managed conservatively. Nowadays, patients with severe symptomatic aortic stenosis are typically managed with TAVI, regardless of their risk to surgery, improving the prognosis of patients and thus achieving an exponential global expansion of its use. However, thromboembolic and hemorrhagic complications remain a latent concern in TAVI recipients. Both complications can appear simultaneously in the periprocedural period or during the follow-up, and when minor, they resolved without apparent sequelae, but in a relevant percentage of cases, they are devastating, overshadowing the benefit achieved with TAVI. Our review outlines the etiology and incidence of thromboembolic complications associated with TAVI, the main current strategies for their prevention, and the implications of its pharmacological management at the follow-up in a TAVI population, mostly frail and predisposed to bleeding complications.
Introduction
The current American (1) and European (2) guidelines for the treatment of patients with valvular heart disease favor transcatheter aortic valve implantation (TAVI) by transfemoral access for patients with aortic stenosis (AS) who are at low to high risk for surgical aortic valve replacement (SAVR). Although the results of its pivotal clinical trials and reports of its clinical use were published, several concerns regarding its neurological safety arose soon afterward.
The expansion of TAVI indication to a younger and less comorbid population has prompted active research into the mechanisms involved in procedure-related stroke and the development of various devices to protect the brain from the passage of emboli during TAVI. Also, the determination of the most balanced antithrombotic strategy after TAVI in terms of ischemic protection and bleeding is a relevant clinical need and is under current quest. In this article, we provide an updated overview on stroke related to TAVI and its most relevant advances in devices aimed at stroke prevention, and on the ongoing clinical research in preventive pharmacological strategies.
Etiology, timing, and mechanism of transcatheter aortic valve implantation-related stroke
Despite great advances in patient management and latest iterations on TAVI devices occurred during the last decade, stroke has remained steady over time and continues to be a frequent TAVI complication with relevant prognostic implications (Table 1). In general, strokes related to TAVI can be divided into procedure-related strokes (acute) and patient- or prosthesis-related strokes (long-term). In addition, the clinical manifestations can be broad, ranging from silent or subclinical events detected as findings in brain imaging studies, to episodes of transitory delirium or acute confusional state, to a major stroke with manifest clinical expression and disabling sequelae. Overt stroke is one of the most fearful and catastrophic complication of TAVI, being strongly associated with morbidity and mortality (3), increasing the average 30-day mortality more than six times in patients who suffer from it than those who do not after TAVI (4). Also, bleeding complications remain a problem to be solved, not only those that occur periprocedural but also those that continue for a long-standing period, the former being more in relation to TAVI vascular access, and the latter to long-term post-TAVI antithrombotic management (5).
Clinical stroke
Stroke occurrence during and after TAVI is likely multifactorial and closely linked with the patients’ risk profile (6). Ischemic stroke can happen during or after TAVI, either in periprocedural days or during the long-term follow-up; is strongly linked to morbidity; and can entirely nullify TAVI prognostic improvements (5–8). TAVI and transcatheter valve components induce a prothrombotic environment in the aortic root (9, 10). Mechanical disruption of atheromatous or calcific debris during different procedural steps of TAVI (crossing of catheters and devices in the aortic arch/valve, during balloon aortic valvuloplasty, during deployment, or during valve post-dilation) may account as the main mechanisms for most of the periprocedural strokes (11, 12). Also, suboptimal intraprocedural anticoagulation levels inducing the formation of thrombi in guidewires and catheters, air embolism, and severe hypotension states may also be involved in the stroke pathophysiology during TAVI. The use of cerebral embolic protection devices (CEPDs) during TAVI may contribute to decrease the procedural stroke risk. Different biological responses to the presence of an aortic bioprosthesis and its materials, such as increased platelet activation and an acute rise in prothrombotic factors, increased shear stress and endothelial injury, altered aortic flow dynamics in the neosinus, and suboptimal antiplatelet effect, may favor the formation of thrombi and embolic phenomena during the first year after TAVI, with the first 3 months being the period of greatest risk (9, 10, 12–14). Also, postprocedural subacute and late events can be at least partly explained by atrial fibrillation (AF), which has been reported in about 20–40% of patients admitted for TAVI, and by the development of new-onset atrial fibrillation (NOAF) in up to 8% of cases during or after the intervention (15–17). In addition to AF, it is likely that the mechanism of late events is also associated with other baseline characteristics known predictors of late cardiovascular events, such as cerebrovascular disease, peripheral artery disease, and/or renal disease, namely the baseline burden of the aged TAVI patient. Therefore, TAVI-related stroke seems to be linked to both increased platelet activation due to endothelial injury after valve deployment and to AF-related thromboembolic risk factors (Figure 1).
Figure 1. Potential mechanisms related to stroke after TAVI and main antithrombotic strategies. TAVI, transcatheter aortic valve implantation; APT, antiplatelet therapy; OAC, oral anticoagulation therapy; TIA, transient ischemic attack.
Subclinical stroke
Different studies have shown the presence of silent cerebral embolic lesions in most patients undergoing percutaneous and surgical aortic valve replacement detected by diffusion-weighted magnetic resonance imaging (DW-MRI) (18, 19). Increasing evidence indicates that these subclinical phenomena may be associated with progressive cognitive deterioration, leading to a neurocognitive decline and dementia (20, 21). The long-term relevance of these clinically “silent” brain lesions still remains unknown, but since they can be found in the vast majority of patients undergoing TAVI, they constitute the hidden part of the iceberg; so, the adoption of preventive measures will be of utmost importance. The recognition of overt strokes and asymptomatic brain lesions after TAVI is largely dependent on the intensity of the neurological and imaging tests used. Therefore, the inclusion of an experienced neurologist in the heart team to assess the neurological integrity after TAVI and to detect any early subtle sign of brain damage is paramount.
Preventive strategies for acute and late strokes in transcatheter aortic valve implantation
Since manipulation of the transcatheter valve in the calcified aortic arch and native aortic valve plays an important role in the genesis of emboli and periprocedural acute stroke (procedure associated origin) (11, 12), cerebral protection devices may provide benefit (22–25). By contrast, strategies for the prevention of subsequent stroke are based on an optimal and balanced antithrombotic therapy to prevent ischemic events without substantially increasing the risk of long-term bleeding.
Cerebral embolic protection devices
Given that most CVEs in patients undergoing TAVI are embolic in nature, the use of CEPDs seems reasonable to reduce debris or embolic material that travels to the brain, subsequently minimizing the risk of stroke and lessen the extent of neurological damage. Previous studies have shown the feasibility and safety of CEPD use (22–25), but its efficacy remains to be clearly demonstrated (26).
Currently, there are four devices with published data, two of them under clinical use, and the other two under active investigation in early phase studies for their potential applications in TAVI and structural heart interventions (Figure 2). Basically, they are divided into two types based on their mechanism of action: devices that capture (totally or partially) debris before it reaches the brain arteries and devices that deflect the debris away from the main arterial branches of the aortic arch.
Figure 2. Cerebral embolic protection devices with published data. (A) Sentinel® Cerebral Protection System (Boston Scientific, Marlborough, Massachusetts). (B) TriGUARD 3 Cerebral Protection Device (Keystone Heart, Tampa, FL, USA, a Venus Medtech Company). (C) Emblok Embolic Protection System (Innovative Cardiovascular Solutions, Grand Rapids, Michigan). (D) ProtEmbo® Cerebral Protection System (Protembis GmbH, Aachen, Germany).
Another classification of devices is based on the brain protection they offer, being partial – covering two of the three main arteries of the aortic arch (brachiocephalic trunk or right common carotid artery and left common carotid artery) – or total (the former two plus the left vertebral artery originating from the left subclavian artery which merges with the right vertebral artery to form the basilar artery, the major supply to the posterior portion of the circle of Willis). The implications of leaving the left subclavian artery and thus the left vertebral artery unprotected are relevant.
Fanning JP and col (27) provided a detailed description of the anatomical distribution and the subsequent cerebral predilection for injury of the cerebral ischemic lesions occurring secondary to TAVI using DW-MRI. The authors observed that the distribution of lesions suggests the posterior circulation and the right hemisphere are particularly vulnerable to perioperative cerebrovascular injury. They found that 59% of all cerebral infarcts occurred in the posterior circulation, and around two-thirds of all lesions affected the right hemisphere. Interestingly, when considering the total volume of infarction, 10,255 μl (90%) occurred in the posterior compared with 1,192 μl (10%) in the anterior circulation (27).
Thus, embolic protection devices that lack coverage of the left subclavian artery also fail to completely protect the posterior circulation, resulting in potentially 19 of 28 cerebral vascular territories and 26% of the brain volume being completely unprotected. The authors hypothesized that the relatively impaired cerebral autoregulation in the posterior versus anterior circulation is a plausible explanation for the observed differences in vulnerability to injury, increasing the importance of providing complete cerebral protection in cases of cardiovascular procedures with risk of cerebral embolization (27).
Sentinel cerebral protection system
The Sentinel® Cerebral Protection System (Boston Scientific, Marlborough, MA, USA) consists of two polyurethane filters with 140-mm-diameter pores fixed in a flexible nitinol radiopaque frame, advanced from a 6-Fr sheath through the right radial or right brachial artery and deployed into the ostia of the brachiocephalic trunk and left common carotid artery (22). It is designed to capture emboli passing to the cerebral circulation in two of the three branches of the aortic arch, leaving the left subclavian open and potentially the left vertebral circulation unprotected (22, 28). The device has CE and FDA approval and is to date the most widely used CEPD in TAVI.
The MISTRAL-C trial (27) (n = 65 patients) and the CLEAN TAVI trial (22) (n = 100 patients) are randomized clinical trials that showed fewer new lesions and a smaller total lesion volumes in the protected group with Sentinel vs. no protection. Also, neurocognitive deterioration was more frequent in patients treated without protection (28).
The SENTINEL U.S. IDE trial (25) was a multicenter study (n = 363 patients) with a 1:1:1 randomization into a safety device arm (n = 123), an imaging device arm (n = 121), and an imaging control arm (n = 119). The authors found debris in 99% of the filters. Despite a reduction in all-cause strokes at 30 days, statistical significance was not met (5.6% for the EPD group vs. 9.1% in the control group; p = 0.25). Also, the decrease in the median total new lesion volume in protected territories (44%) evaluated by DW-MRI 2–7 days after TAVI was not statistically significant (102.8 mm3, IQR 36.9–423.2 mm3 in the device arm vs. 178.0 mm3, IQR 34.3–482.5 mm3 in the control arm; p = 0.33). It is noteworthy that using the procedural stroke classification by NeuroARC definition, the CEPD group showed a significant reduction in stroke within 72 h after TAVI when compared with the unprotected group (3.0 vs. 8.2%; p = 0.053).
In total, two large ongoing randomized trials will probably bring definitive evidence on the efficacy of Sentinel on stroke prevention in TAVI: Stroke PROTECTion With SEntinel During Transcatheter Aortic Valve Replacement (PROTECTED TAVR) (NCT04149535, N = 3,000) and British Heart Foundation Randomised Trial of Routine Cerebral Embolic Protection in Transcatheter Aortic Valve Implantation (BHF PROTECT-TAVI) (ISRCTN16665769, N = 7,730).
TriGUARD 3™ cerebral protection device
The TriGUARD 3™ Cerebral Protection Device (Keystone Heart, Tampa, FL, USA, a Venus Medtech Company) is a deflection device positioned in the aortic arch to provide protection to all three branches of the aortic arch, including the left subclavian artery (23). It is placed through a transfemoral access via a 9-Fr femoral arterial sheath, which also allows for concomitant use of a 6-Fr pigtail catheter. The device is composed of a semi-permeable nitinol mesh with pores of 115 × 145 mm, which deflects particles larger than 140 μm (24).
The first and latest generation of the TriGUARD was assessed in four prospective clinical studies of TAVI recipients in the United States and Europe showing a numerical reduction (non-statistically significant) in stroke rates and a lower total lesion volume in cases who have complete coverage of all brain branches than in cases who were not protected in a combined analysis (23, 24).
The feasibility and safety of this device were investigated in DEFLECT I (29) and DEFLECT II (30) trials, which were prospective, single-arm studies (n = 37 patients and 14 patients, respectively). Data on DW-MRI showed that in the DEFLECT I trial (28), the presence of new brain infarcts was comparable with those in historical controls (82 vs. 76%, p = NS). However, as compared with historical data, the total lesion volume per patient was 34% smaller (0.2 vs. 0.3 cm3). Similarly, the DEFLECT II study (30) comparing the DWI-MRI of these patients with that of a historical control group revealed no significant reduction in the number of lesions [median 5.5 vs. 5.0, p = 0.857] but a substantial reduction in the mean lesion volume per patient [median 13.8 vs. 25.1, p = 0.049].
The DEFLECT III trial (31) (n = 85 patients) was a single-blind multicenter randomized trial in which patients with TAVI were randomized to either EPD (n = 46) with TriGUARD HDH or no CEPD (n = 39). DW-MRI was performed in all patients on days 4 ± 2 and 30 ± 7 after TAVI, as well as multiple serial neurological assessments. The dropout rate for DW-MRI assessment at 4 days was 30% (33 of 46 in the CEPD group and 26 of 39 in the no-CEPD group). Device success was achieved in 88.9% of the patients (40 of 45). The primary in-hospital procedural safety endpoints (death, stroke, life-threatening or disabling bleeding, stage 2 or 3 acute renal failure, or major vascular complications) did not differ statistically in TriGUARD HDH (21.7%) compared with the control group (30.8%, p = 0.34), but in cases with complete brain protection, TriGUARD HDH was associated with a higher rate of freedom from new cerebral lesions at 1 month (26.9 vs. 11.5%, p not reported) and less neurological damage assessed by the National Institutes of Health Stroke Scale (NIHSS) (3.1 vs. 15.4%, p = 0.16).
The REFLECT I trial (n = 258 patients of the initially planned 375 patients) was a multicenter (20 U.S. and 6 European centers), randomized controlled trial that evaluated the safety, efficacy, and performance of the TriGUARD™ HDH device in patients undergoing TAVI (23). There were 54 roll-in patients and 204 patients randomized 2:1 to TriGUARD HDH device (n = 141) or control (n = 63). The trial was suspended by recommendation of the data safety monitoring committee before patients’ enrollment was completed. The primary efficacy endpoint was a hierarchical composite of (i) all-cause mortality or any stroke at 30 days, (ii) NIHSS worsening at 2–5 days or Montreal Cognitive Assessment worsening at 30 days, and (iii) total volume of brain ischemic lesions detected by DW-MRI at 2–5 days. Complete protection of all three cerebral vessels throughout the TAVI procedure was achieved in 57.3% (78/136).
Compared with the performance goal, the primary safety outcome was met (21.8 vs. 34.4%, p < 0.0001). The primary hierarchical efficacy endpoint was comparable between the groups, with a mean score (higher is better) of −5.3 ± 99.8 for TriGUARD and 11.8 ± 96.4 for controls (p = 0.314), corresponding to a win percentage of 44.6% for TriGUARD and 55.4% without protection. Comparable results were obtained in patients with complete cerebral coverage (mean score of −2.0 ± 71.4 for TriGUARD and 2.5 ± 70.1 for controls, p = 0.766, with a similar win percentage of 48 vs. 52%). When compared with the controls, covert central nervous system damage was reduced with TriGUARD both in-hospital (46.1 vs. 60.3%, p = 0.0698) and at 5 days (61.7 vs. 76.2%, p = 0.054).
In 18 U.S. sites, the REFLECT II U.S. trial (24) enrolled 220 of the 345 patients planned (63.8%), with 41 roll-in and 179 randomized patients (121 TriGUARD 3 and 58 control subjects). The study suffered an early discontinuation of the enrollment by the sponsor after the U.S. Food and Drug Administration advised for unblinded safety data assessment. Complete cerebral coverage (before, during, and after TAVI) was achieved in 59.7% (94/157), and device interaction was reported in 9.6% (15/157). The primary safety endpoint was met compared with the performance goal (15.9 vs. 34.4%; p < 0.0001), but the primary hierarchal efficacy endpoint at 30 days (death or stroke at 30 days, NIHSS score worsening in-hospital, and cerebral ischemic lesions on DW-MRI at 2 to 5 days) was not met (mean scores [higher is better]: −8.58 TG3 vs. 8.08 control; p = 0.857).
Emblok® embolic protection system
The Emblok Embolic Protection System (Innovative Cardiovascular Solutions, Grand Rapids, MI, USA) is a device designed to protect all supraaortic vessels by a full circumferential coverage of the aortic arch (32). The delivery system is an 11-Fr catheter compatible to be deployed through a single access site supported by 0.035 guidewire and integrates a 4-Fr radiopaque pigtail catheter for aortogram performance. Anatomical criteria for its use include an ascending aorta length ≥ 9 cm, an ascending aorta or aortic arch diameter between 30 and 35 mm, and an arterial femoral access suitable for an 11-Fr delivery system. The filter is made of a polyurethane mesh with a pore size of 125 μm, supported by a nitinol frame positioned just proximal to the brachiocephalic trunk. Once the transcatheter valve is deployed, the Emblok system must be recaptured to be able to retrieve the transcatheter delivery system from the body (32).
The Emblok device (n = 20 patients) was tested in a prospective, multicenter, non-randomized, first-in-man pilot study intended to evaluate its efficacy and safety during TAVI (32). The device was successfully positioned in all the cases, and no major adverse cardiovascular and cerebrovascular events occurred at the 30-day follow-up. Significant debris was captured in 18 (90%) filters, but 19 (95%) patients had new brain lesions at postprocedural DW-MRI. The median number of new lesions per patient was 10.00 (interquartile range [IQR]: 4.75 to 15.25), the total new lesion volume was 199.9 mm3 (IQR: 83.9 to 447.5 mm3), and the mean lesion volume per lesion was 42.5 mm3 (IQR: 21.5 to 75.6 mm3).
ProtEmbo® cerebral protection system
The ProtEmbo® Cerebral Protection System (Protembis GmbH, Aachen, Germany) is a temporary, intra-aortic embolic deflection filter used as an adjunct device during transcatheter heart interventions and is the only available device that can be positioned through a 6-Fr left radial access (33, 34). ProtEmbo is designed to provide complete cerebral protection and inserted in the beginning of the procedure prior to the TAVI device and removed following the completion of the TAVI procedure. The device consists of (1) a heparin-coated, 60-μm-pore size mesh (currently the smallest pore size of CEPDs), (2) a self-expanding nitinol frame that when expanded ensures sufficient coverage of all cerebral vessels of the aortic arch and includes radiopaque markers for fluoroscopic visualization and precise device placement, and (3) a delivery unit. The device is delivered unexpanded and deployed by unsheathing the self-expanding filter. A handle provides a simple user interface for preparation, delivery, deployment, and removal of the device. The device is loaded into a commercially available delivery catheter and placed into the aortic arch using a commercially available guiding sheath via the left radial artery (33, 34).
The first-generation ProtEmbo device was shown to be safe and feasible in the first-in-human PROTEMBO SF trial (n = 4 patients) in two clinical sites in Europe (33). The PROTEMBO C trial (n = 41 patients) was a prospective, non-randomized, multicenter (eight sites in Europe) study designed to evaluate the safety and performance of the second-generation ProtEmbo Cerebral Protection System in patients undergoing TAVI (34). The primary safety endpoint was the rate of major adverse cardiac and cerebrovascular events (MACCE) at 30 days, as per the Valve Academic Research Consortium 2 definition, and the primary performance endpoint was the composite rate of technical success compared with performance goals (33). Secondary analyses included the brain DW-MRI new lesion volume and rate of death, or all strokes compared with historical data. Both primary endpoints were met early in this study. MACCE at 30 days were 8.1% (3/37) (upper limit of the 95% confidence interval [CI]: 21.3% versus performance goals 25%, p = 0.009), and technical success was 94.6% (35/37) (lower limit of the 95% CI: 82.3% versus performance goals 75%, p = 0.003). The new DW-MRI lesion volume with ProtEmbo was lower than that in historical data, and most patients who completed the MRI follow-up (87%, 27/31) were free of any single lesion larger than 150 mm3.
Antithrombotic therapy in transcatheter aortic valve implantation
The current European (2) and American (1) guidelines for the management of valvular heart disease have modified their recommendation favoring the use of single antiplatelet therapy (SAPT) over dual antiplatelet therapy (DAPT) in TAVI patients without an underlying indication for oral anticoagulation (OAC), and in OAC alone over the association of OAC with antiplatelet therapy for TAVI patients requiring lifelong OAC. SAPT on top of vitamin K antagonists (VKAs) may be beneficial only in specific subsets (i.e., TAVI patients with recent acute coronary syndrome or recent coronary stenting). VKA or a direct-acting oral anticoagulant (DOAC) may be considered if OAC is indicated in the absence of contraindications. VKA is indicated in cases of clinical valve thrombosis, accompanied with symptoms or high transvalvular gradient, whereas its role in asymptomatic patients or with those with a normal transvalvular gradient (subclinical leaflet thrombosis) is currently not yet defined. A consensus document of the European Society of Cardiology Working Group on Thrombosis and the European Association of Percutaneous Cardiovascular Interventions (35) supports these recommendations.
Periprocedural antithrombotic management
The decision to start the antithrombotic therapy before TAVI is not standardized and is primarily left to the physicians’ discretion. However, preprocedural DAPT with aspirin and clopidogrel has been linked to a two-fold increased risk of in-hospital bleeding and transfusions compared with SAPT or no antiplatelet medication, with no clear benefit in terms of ischemic protection (36, 37). Low-dose aspirin is the recommended pre-TAVI treatment in patients without OAC indication (35). Although most patients with TAVI have high residual platelet reactivity to clopidogrel (9, 38), no additional benefits on thromboembolic event reduction have been demonstrated with clopidogrel maintenance or with loading dose prior to TAVI (39).
Among patients on OAC, both VKAs and DOACs are usually stopped before the procedure. A bridging strategy with low-molecular weight heparin is optional and, based on local practice, is restarted for OAC after an uncomplicated intervention (36, 37). Recent evidence suggests that TAVI in patients with OAC may be as safe as and equivalent to an OAC interruption strategy (40–42).
During the intervention, unfractionated heparin is the most used strategy and may be reversed with protamine sulfate at procedure completion according to local practice (43). Although the use of protamine to reverse unfractionated heparin (UFH) after the procedure is not widespread in all TAVI centers and small studies have found no benefit in its use (44), some other evidence points in favor of this strategy after the procedure. In a prospective observational study of 873 patients undergoing TAVI (43), authors found lower rates of the primary composite outcome (a composite of 30-day all-cause mortality and major and life-threatening bleeding) in the group with UFH reversal using protamine (3.2%) than in the control group without heparin reversal (8.7%; p = 0.003). This finding was driven by a reduction in major and life-threatening bleeding complications (1.0 vs. 4.1%; p = 0.008; and 0.1 vs. 2.6%; p < 0.001, respectively). Also, in the control group, the hemoglobin level at 24 h was lower, need for transfusion was higher, and hospital stay was longer, suggesting the benefits for the prevention of clinically relevant complications by protamine administration. Another relevant observation was that thromboembolic complications were equal between the groups. These data are reassuring regarding one of the main concerns of protamine use, which are thrombotic complications, primarily at the transcatheter valve level or in patients with a recent coronary stent. The use of protamine was independently associated with the reduction of the primary composite outcome in the multivariate analysis. Hence, the EAPCI states that protamine sulfate may be used before vascular access closure to reverse anticoagulation with UFH to prevent vascular access site complications and bleedings (35).
The role of procedural bivalirudin is limited to patients who are unable to receive heparin (i.e., allergy and heparin-induced thrombocytopenia) (45). Ongoing studies [Periprocedural Continuation Versus Interruption of Oral Anticoagulant Drugs During Transcatheter Aortic Valve Implantation trial (POPular PAUSE TAVI), NCT04437303] will provide more evidence on this topic.
Antithrombotic management after transcatheter aortic valve implantation
From the latest ACC/AHA guidelines (1), a SAPT of aspirin (75–100 mg daily) is recommended after TAVI in the absence of other indications for oral anticoagulants (class of recommendation: 2a, level of evidence: B-R), while DAPT (aspirin 75–100 mg plus clopidogrel 75 mg daily) for 3 to 6 months has been retroceded to class of recommendation 2b.
In the same line, in the ESC/EACTS guidelines (2), lifelong SAPT is recommended after TAVI in patients with no baseline indication for OAC (class of recommendation: I, level of evidence: A), while the routine use OAC is not recommended after TAVI in patients with no baseline indication for OAC (class of recommendation: III, level of evidence: B) (Figure 3).
Figure 3. Summary of current recommendations of the European and American guidelines on the antithrombotic regimen after TAVI, including the main studies assessing a variety of antiplatelet and anticoagulant combinations. TAVI, transcatheter aortic valve implantation; OAC, oral anticoagulation; CAD, coronary artery disease; PAD, peripheral artery disease; CVD, cerebrovascular disease; CKD, chronic kidney disease; DM, diabetes mellitus; ACS, acute coronary syndrome; PCI, percutaneous coronary intervention; ESC, European Society of Cardiology; EACTS, European Association for Cardio-Thoracic Surgery; AHA, American Heart Association; ACC, American College of Cardiology; ASA, acetylsalicylic acid; DAPT, dual antiplatelet therapy; SAPT, single antiplatelet therapy; HBR, high-bleeding risk; VKA, vitamin K antagonist; LBR, low bleeding risk; DOAC, direct oral anticoagulant.
Previous observational studies and recent randomized control trials have demonstrated in patients undergoing TAVI with no underlying indication of OAC, the use of DAPT has no advantage over SAPT for the prevention of ischemic events and increases the risk of bleeding. A total of three small-scale RCTs did not find differences between DAPT and SAPT after TAVI on ischemic outcomes (46–48). In the POPular TAVI trial cohort A (49), 665 patients undergoing TAVI without an indication for OAC were randomized to aspirin 100 mg or aspirin 100 mg + clopidogrel 75 mg for 3 months following TAVI (no loading dose prior TAVI). At 1 year, bleeding and the composite endpoint of bleeding or thromboembolic events were significantly less frequent with aspirin monotherapy than with DAPT (15.1 vs. 26.6%, respectively, relative risk [RR] 0.57; 95% CI: 0.42–0.77; p = 0.001 for bleeding); and non-procedure-related bleeding (15.1 vs. 24.9%; RR, 0.61 [95% CI, 0.44–0.83]; p = 0.005), and this benefit was driven by less major bleeding events, mostly due to periprocedural bleeding. In addition, the rates of ischemia events and valve function measurements were comparable in both groups. However, there are certain scenarios, where in the absence of increased bleeding risk, DAPT should be considered for a limited period (i.e., within 1–12 months), such as recent acute coronary syndrome, complex coronary stenting prior TAVI or during TAVI (chimney stenting), valve-in-valve procedures, large aortic arch atheromas, and previous non-cardioembolic stroke.
Also, the use of OAC (either VKA or DOAC) has not shown evidence to support its use. The GALILEO trial (n = 1,644 patients) tested rivaroxaban 10 mg/d (plus aspirin for the first 3 months) versus aspirin 75 to 100 mg/d (plus clopidogrel 75 mg/d for the first 3 months). The authors found a higher risk of thromboembolic complications (hazard ratio [HR], 1.35 [95% CI, 1.01–1.81]; p = 0.04), death (HR, 1.69 [95% CI, 1.13–2.53]), and major, disabling, or life-threatening bleeding (HR, 1.50 [95% CI, 0.95–2.37]; p = 0.08) with the OAC strategy (50). Notably, in the GALILEO-4D substudy (n = 231), patients treated with rivaroxaban plus aspirin showed a less frequency of subclinical leaflet motion anomalies and leaflet thrombosis than patients treated with a DAPT regimen (51). The ADAPT-TAVR (n = 229) was an open-label trial that evaluated the use of edoxaban for 6 months or DAPT with ASA plus clopidogrel on leaflet thrombosis assessed by 4DCT in patients without indication of OAC. At 6 months after TAVI, the researchers noted no link between subclinical leaflet thrombosis and an increased risk of cerebral thromboembolism or neurological impairment (52). Also, no statistically significant difference between edoxaban and DAPT in leaflet thrombosis incidents were found, although edoxaban group patients did show a lower trend (9.8 vs. 18.4% for DAPT; absolute difference: −8.5%; 95% CI: −17.8 to 0.8%; p = 0.076). The edoxaban group had numerically more new cerebral lesions on DW-MRI than the DAPT group (25.0 vs. 20.2%, respectively; difference, 4.8%; 95% CI: −6.4 to 16.0%; p = 0.40). The median total new lesion number (1 for each group; p = 0.85) and volume (36.6 mm3 for edoxaban and 43.9 mm3 for DAPT; p = 0.88) were also not different between the two groups. Neurocognitive outcomes measured by the NIHSS, modified Rankin Scale, and Montreal Cognitive Assessment, and any or major bleeding events (11.7% of the edoxaban patients versus 12.7% on DAPT, hazard ratio 0.93; 95% CI: 0.44–1.96) were comparable between the two groups. Similar data on the potential lack of benefit on the prevention of silent cerebral lesions after TAVI with OAC (acenocoumarol) compared with DAPT (aspirin + clopidogrel) has been presented (53).
For patients undergoing TAVI with underlying indication of long-term OAC, definitive evidence supporting DOACs over VKAs after TAVI is currently lacking. Observational data have shown inconsistent results regarding the thromboembolic risk associated with DOACs in the post-TAVI population. A collaborative registry between German and Italian centers (n = 962) showed higher all-cause mortality, myocardial infarction, and cerebrovascular events at 1 year with DOACs (rivaroxaban, apixaban, or dabigatran) than with VKA, with a comparable 1-year event rates of bleeding (54), while in a nationwide observational cohort Danish study (n = 735), a similar risk of thromboembolism, bleeding, or all-cause mortality post-TAVI among DOACs (dabigatran, rivaroxaban, apixaban, or edoxaban) and VKAs (warfarin or phenprocoumon) was found (55). According to the data from the PARTNER 2 cohort, OAC alone was ineffective in reducing 2-year stroke, while antiplatelet therapy with or without anticoagulant therapy significantly lowered the risk of stroke at 2 years after TAVI. OAC, on the other hand, was linked to a lower risk of combined death and stroke when taken alone (56).
The POPular TAVI cohort B (n = 326) evaluated the safety and efficacy of OAC plus clopidogrel or OAC alone post-TAVI (57). The rate of non-procedural bleeding at 1 year was considerably higher in the OAC plus clopidogrel than in the OAC alone group (34 vs. 21.7%, p = 0.02), while the composite of cardiovascular death, stroke, or MI was comparable between the two treatment strategies non-inferior (17.3 and 13.4%, respectively; 95% CI for non-inferiority, −11.9 to 4.0).
The ENVISAGE-TAVI AF (n = 1,426) trial compared edoxaban with VKAs in patients with an indication for anticoagulation (58). Regarding NACE (death from any cause, myocardial infarction, ischemic stroke, systemic thromboembolism, valve thrombosis, or major bleeding), edoxaban was non-inferior to VKA (17.3 vs. 16.5 per 100 person-years; HR, 1.05; 95% CI, 0.85 to 1.31; p = 0.01 for non-inferiority), but edoxaban was associated with a higher incidence of major bleeding (mostly gastrointestinal bleeds) than VKA, mainly among patients who received specified concomitant antiplatelet therapy (9.7 vs. 7.0 per 100 person-years; HR, 1.40; 95% CI, 1.03 to 1.91; p = 0.93 for non-inferiority). No valve thrombosis events were reported in the trial.
The recently published ATLANTIS trial (n = 1,500) tested apixaban 5 mg (2.5 mg if impaired renal function or concomitant antiplatelet therapy) (n = 749) two times daily, or standard of care (n = 751) (59). In stratum 1, patients in the standard-of-care group received a VKA, while in stratum 2, patients received antiplatelet therapy with aspirin and clopidogrel, if there was an indication for anticoagulation or not, respectively. The primary endpoint was the composite of death, myocardial infarction, stroke or transient ischemic attack, systemic embolism, intracardiac or bioprosthesis thrombosis, deep vein thrombosis or pulmonary embolism, and life-threatening, disabling, or major bleeding over the 1-year follow-up. The primary safety endpoint was major, disabling, or life-threatening bleeding. Apixaban was not superior to standard of care globally (18.4 vs. 20.1%; HR 0.92; 95% CI 0.73–1.16; P interaction = 0.57) and in each stratum arms (indication or not for OAC). Similar to observed in the GALILEO trials (50, 51), subclinical valve thrombosis was reduced with apixaban compared with the aspirin and clopidogrel regimen (HR 0.19; 95% CI 0.08–0.46), while a signal of higher non-cardiovascular mortality was observed with apixaban.
Ongoing trials (AVATAR, NCT02735902; Strategies to Prevent Transcatheter Heart Valve Dysfunction in Low Risk Transcatheter Aortic Valve Replacement, NCT03557242; REACTIC-TAVI, NCT04331145; REAC-TAVI 2, NCT05283356; and REDOX-TAVI, NCT04171726) will provide more information regarding the antithrombotic management on this complex field.
The conventional TAVI population carries a large burden of comorbidities that make them more susceptible to long-term cerebrovascular events. The incidence of diabetes mellitus, coronary artery disease, history of atrial fibrillation, previous stroke, or peripheral vascular disease raises up to 60–70% in TAVI recipients, including high- to intermediate-risk (60–64) to low-risk patients (65, 66).
In these patients, achieving an optimal long-term antithrombotic strategy that provides protection from future ischemic events (stroke, myocardial infarction, or valve thrombosis) without significantly increasing the cumulative risk of bleeding over time is crucial. This long-term treatment is very relevant primarily in the low-risk population and in younger patients with a long life expectancy in whom extending the durability of the aortic bioprosthesis as much as possible is essential to avoid repeat interventions, as well as in certain scenarios, such as bicuspid valve, valve-in-valve, or valve-in-TAV procedures. Also, it should be in line with the optimal medical management of their comorbidities. Some studies are in this direction (NCT05283356, NCT03042104, NCT02825134, NCT03972644, NCT04204915, and NCT03094143), exploring the lifetime management of the TAVI population and will provide data in future.
Conclusion
In current TAVI practice, the rate of overt stroke during or early after TAVI is relatively low (2–4%) (5) but remain stable over the years (4). However, it may represent only the tip of the iceberg of cerebral cardioembolic events, being microembolization and cerebral “silent” injury more frequent phenomena, but still poorly understood with a potential substantial impact on mid- and long-term cognitive function. Although there is still not enough clinical evidence to conclusively establish a direct relationship between the use of CEPDs and stroke prevention, the available studies point to significant protection from periprocedural cerebrovascular events. Important studies are under way to clarify this point (NCT04149535 and ISRCTN16665769). Therefore, in light of TAVI expansion to lower risk patients and the younger population, measures to abate neurological risks during and after TAVI are warranted.
Author contributions
VJ, RE, and AI developed the concept, design, and drafted the manuscript. JB, PJ, GB, BC, and CV contributed substantially to the critical revision of the manuscript and add important intellectual content. All authors contributed to the article and approved the submitted version.
Funding
This research has been partially supported by the Axencia Galega de Innovación – GAIN through program code IN607B-2021/18.
Conflict of interest
VJ serves as clinical advisor for Protembis GmbH.
The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Publisher’s note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
References
1. Otto CM, Nishimura RA, Bonow RO, Carabello BA, Erwin JP III, Gentile F, et al. 2020 ACC/AHA guideline for the management of patients with valvular heart disease: a report of the American college of cardiology/American heart association joint committee on clinical practice guidelines. Circulation. (2021) 143:e72–227. doi: 10.1161/CIR.0000000000000923
2. Vahanian A, Beyersdorf F, Praz F, Milojevic M, Baldus S, Bauersachs J, et al. 2021 ESC/EACTS guidelines for the management of valvular heart disease. Eur Heart J. (2022) 43:561–632. doi: 10.1093/ejcts/ezac209
3. Vlastra W, Jimenez-Quevedo P, Tchétché D, Chandrasekhar J, de Brito FS Jr., Barbanti M, et al. Predictors, incidence, and outcomes of patients undergoing transfemoral transcatheter aortic valve implantation complicated by stroke. Circ Cardiovasc Interv. (2019) 12:e007546. doi: 10.1161/CIRCINTERVENTIONS.118.007546
4. Huded CP, Tuzcu EM, Krishnaswamy A, Mick SL, Kleiman NS, Svensson LG, et al. Association between transcatheter aortic valve replacement and early postprocedural stroke. JAMA. (2019) 321:2306–15. doi: 10.1001/jama.2019.7525
5. Guedeney P, Mehran R, Collet JP, Claessen BE, Ten Berg J, Dangas GD. Antithrombotic therapy after transcatheter aortic valve replacement. Circ Cardiovasc Interv. (2019) 12:e007411. doi: 10.1161/CIRCINTERVENTIONS.118.007411
6. Matsuda Y, Nai Fovino L, Giacoppo D, Scotti A, Massussi M, Ueshima D, et al. Association between surgical risk and 30-day stroke after transcatheter versus surgical aortic valve replacement: a systematic review and meta-analysis. Catheter Cardiovasc Interv. (2021) 97:E536–43. doi: 10.1002/ccd.29105
7. Nombela-Franco L, Webb JG, de Jaegere PP, Toggweiler S, Nuis RJ, Dager AE, et al. Timing, predictive factors, and prognostic value of cerebrovascular events in a large cohort of patients undergoing transcatheter aortic valve implantation. Circulation. (2012) 126:3041–53. doi: 10.1161/CIRCULATIONAHA.112.110981
8. Bosmans J, Bleiziffer S, Gerckens U, Wenaweser P, Brecker S, Tamburino C, et al. The incidence and predictors of early- and mid-term clinically relevant neurological events after transcatheter aortic valve replacement in real-world patients. J Am Coll Cardiol. (2015) 66:209–17. doi: 10.1016/j.jacc.2015.05.025
9. Jimenez Diaz VA, Tello-Montoliu A, Moreno R, Cruz Gonzalez I, Baz Alonso JA, Romaguera R, et al. Assessment of platelet reactivity after transcatheter aortic valve replacement: the REAC-TAVI trial. JACC Cardiovasc Interv. (2019) 12:22–32. doi: 10.1016/j.jcin.2018.10.005
10. Hatoum H, Gooden SCM, Sathananthan J, Sellers S, Kutting M, Marx M, et al. Neosinus and sinus flow after self-expanding and balloon-expandable transcatheter aortic valve replacement. JACC Cardiovasc Interv. (2021) 14:2657–66. doi: 10.1016/j.jcin.2021.09.013
11. Kahlert P, Al-Rashid F, Döttger P, Mori K, Plicht B, Wendt D, et al. Cerebral embolization during transcatheter aortic valve implantation: a transcranial doppler study. Circulation. (2012) 126:1245–55. doi: 10.1161/CIRCULATIONAHA.112.092544
12. Erdoes G, Basciani R, Huber C, Stortecky S, Wenaweser P, Windecker S, et al. Transcranial doppler-detected cerebral embolic load during transcatheter aortic valve implantation. Eur J Cardiothorac Surg. (2012) 41:778–83. doi: 10.1093/ejcts/ezr068
13. Merie C, Kober L, Skov Olsen P, Andersson C, Gislason G, Skov Jensen J, et al. Association of warfarin therapy duration after bioprosthetic aortic valve replacement with risk of mortality, thromboembolic complications, and bleeding. JAMA. (2012) 308:2118–25. doi: 10.1001/jama.2012.54506
14. Noble S, Asgar A, Cartier R, Virmani R, Bonan R. Anatomo-pathological analysis after corevalve revalving system implantation. EuroIntervention. (2009) 5:78–85. doi: 10.4244/EIJV5I1A12
15. Tarantini G, Mojoli M, Urena M, Vahanian A. Atrial fibrillation in patients undergoing transcatheter aortic valve implantation: epidemiology, timing, predictors, and outcome. Eur Heart J. (2017) 38:1285–93. doi: 10.1093/eurheartj/ehw456
16. Carroll JD, Mack MJ, Vemulapalli S, Herrmann HC, Gleason TG, Hanzel G, et al. STS-ACC TVT registry of transcatheter aortic valve replacement. Ann Thorac Surg. (2021) 111:701–22. doi: 10.1016/j.athoracsur.2020.09.002
17. Vora AN, Dai D, Matsuoka R, Harrison JK, Hughes GC IV, Sherwood MW, et al. Incidence, management, and associated clinical outcomes of new-onset atrial fibrillation following transcatheter aortic valve replacement: an analysis from the STS/ACC TVT registry. JACC Cardiovasc Interv. (2018) 11:1746–56. doi: 10.1016/j.jcin.2018.05.042
18. Ghanem A, Müller A, Nähle CP, Kocurek J, Werner N, Hammerstingl C, et al. Risk and fate of cerebral embolism after transfemoral aortic valve implantation: a prospective pilot study with diffusion-weighted magnetic resonance imaging. J Am Coll Cardiol. (2010) 55:1427–32. doi: 10.1016/j.jacc.2009.12.026
19. Kahlert P, Knipp SC, Schlamann M, Thielmann M, Al-Rashid F, Weber M, et al. Silent and apparent cerebral ischemia after percutaneous transfemoral aortic valve implantation: a diffusion-weighted magnetic resonance imaging study. Circulation. (2010) 121:870–8. doi: 10.1161/CIRCULATIONAHA.109.855866
20. De Carlo M, Liga R, Migaleddu G, Scatturin M, Spaccarotella C, Fiorina C, et al. Evolution, predictors, and neurocognitive effects of silent cerebral embolism during transcatheter aortic valve replacement. JACC Cardiovasc Interv. (2020) 13:1291–300. doi: 10.1016/j.jcin.2020.03.004
21. Woldendorp K, Indja B, Bannon PG, Fanning JP, Plunkett BT, Grieve SM. Silent brain infarcts and early cognitive outcomes after transcatheter aortic valve implantation: a systematic review and meta-analysis. Eur Heart J. (2021) 42:1004–15. doi: 10.1093/eurheartj/ehab002
22. Haussig S, Mangner N, Dwyer MG, Lehmkuhl L, Lücke C, Woitek F, et al. Effect of a cerebral protection device on brain lesions following transcatheter aortic valve implantation in patients with severe aortic stenosis: the CLEAN-TAVI randomized clinical trial. JAMA. (2016) 316:592–601. doi: 10.1001/jama.2016.10302
23. Lansky AJ, Makkar R, Nazif T, Messé S, Forrest J, Sharma R, et al. A randomized evaluation of the triguard™ HDH cerebral embolic protection device to reduce the impact of cerebral embolic lesions after transcatheter aortic valve implantation: the REFLECT I trial. Eur Heart J. (2021) 42:2670–9. doi: 10.1093/eurheartj/ehab213
24. Nazif TM, Moses J, Sharma R, Dhoble A, Rovin J, Brown D, et al. Randomized evaluation of triguard 3 cerebral embolic protection after transcatheter aortic valve replacement: REFLECT II. JACC Cardiovasc Interv. (2021) 14:515–27. doi: 10.1016/j.jcin.2020.11.011
25. Kapadia SR, Kodali S, Makkar R, Mehran R, Lazar RM, Zivadinov R, et al. Protection against cerebral embolism during transcatheter aortic valve replacement. J Am Coll Cardiol. (2017) 69:367–77.
26. Isogai T, Bansal A, Vanguru HR, Agrawal A, Shekhar S, Puri R, et al. Cerebral embolic protection and stroke-related mortality following transcatheter aortic valve replacement. JACC Cardiovasc Interv. (2022) 15:569–71. doi: 10.1016/j.jcin.2022.01.007
27. Fanning JP, Wesley AJ, Walters DL, Wong AA, Barnett AG, Strugnell WE, et al. Topographical distribution of perioperative cerebral infarction associated with transcatheter aortic valve implantation. Am Heart J. (2018) 197:113–23. doi: 10.1016/j.ahj.2017.12.008
28. Van Mieghem NM, van Gils L, Ahmad H, van Kesteren F, van der Werf HW, Brueren G, et al. Filter-based cerebral embolic protection with transcatheter aortic valve implantation: the randomized MISTRAL-C trial. EuroIntervention. (2016) 12:499–507. doi: 10.4244/EIJV12I4A84
29. Baumbach A, Mullen M, Brickman AM, Aggarwal SK, Pietras GG, Forrest JK, et al. Safety and performance of a novel embolic deflection device in patients undergoing transcatheter aortic valve replacement: results from the DEFLECT I study. EuroIntervention. (2015) 11:75–84. doi: 10.4244/EIJY15M04_01
30. Samim M, van der Worp B, Agostoni P, Hendrikse J, Budde RP, Nijhoff F, et al. TriGuard™ HDH embolic deflection device for cerebral protection during transcatheter aortic valve replacement. Catheter Cardiovasc Interv. (2017) 89:470–7. doi: 10.1002/ccd.26566
31. Lansky AJ, Schofer J, Tchetche D, Stella P, Pietras CG, Parise H, et al. A prospective randomized evaluation of the triguard HDH embolic DEFLECTION device during transcatheter aortic valve implantation: results from the DEFLECT III trial. Eur Heart J. (2015) 36:2070–8. doi: 10.1093/eurheartj/ehv191
32. Latib A, Mangieri A, Vezzulli P, Spagnolo P, Sardanelli F, Fellegara G, et al. First-in-man study evaluating the emblok embolic protection system during transcatheter aortic valve replacement. JACC Cardiovasc Interv. (2020) 13:860–8. doi: 10.1016/j.jcin.2019.11.017
33. Mylotte D, Narbute I, Neylon A, Ulrich S, Nikos W, Renu W, et al. TCT-43 first-in-human experience of a novel transradial device for embolic deflection during transcatheter aortic valve replacement. J Am Coll Cardiol. (2018) 72:B19. doi: 10.1016/j.jacc.2018.08.1127
34. Jagielak D, Targonski R, Frerker C, Abdel-Wahab M, Wilde J, Werner N, et al. Safety and performance of a novel cerebral embolic protection device for transcatheter aortic valve implantation: the PROTEMBO C trial. EuroIntervention. (2022) Epub ahead of print.
35. Ten Berg J, Sibbing D, Rocca B, Van Belle E, Chevalier B, Collet JP, et al. Management of antithrombotic therapy in patients undergoing transcatheter aortic valve implantation: a consensus document of the ESC working group on thrombosis and the European association of percutaneous cardiovascular interventions (EAPCI), in collaboration with the ESC council on valvular heart disease. Eur Heart J. (2021) 42:2265–9. doi: 10.1093/eurheartj/ehab196
36. Hioki H, Watanabe Y, Kozuma K, Nara Y, Kawashima H, Kataoka A, et al. Pre-procedural dual antiplatelet therapy in patients undergoing transcatheter aortic valve implantation increases risk of bleeding. Heart. (2017) 103:361–7. doi: 10.1136/heartjnl-2016-309735
37. Zimarino M, Barbanti M, Dangas GD, Testa L, Capodanno D, Stefanini GG, et al. Early adverse impact of transfusion after transcatheter aortic valve replacement: a propensity-matched comparison from the TRITAVI registry. Circ Cardiovasc Interv. (2020) 13:e009026. doi: 10.1161/CIRCINTERVENTIONS.120.009026
38. Tousek P, Kocka V, Sulzenko J, Bednar F, Linkova H, Widimsky P. Pharmacodynamic effect of clopidogrel in patients undergoing transcatheter aortic valve implantation. Biomed Res Int. (2013) 2013:386. doi: 10.1155/2013/386074
39. Nijenhuis VJ, Ten Berg JM, Hengstenberg C, Lefèvre T, Windecker S, Hildick-Smith D, et al. Usefulness of clopidogrel loading in patients who underwent transcatheter aortic valve implantation (from the BRAVO-3 randomized trial). Am J Cardiol. (2019) 123:1494–500. doi: 10.1016/j.amjcard.2019.01.049
40. Tagliari AP, Perez-Camargo D, Ferrari E, Haager PK, Jörg L, Gennari M, et al. Pre-operative continued oral anticoagulation impact on early outcomes after transcatheter aortic valve implantation. Am J Cardiol. (2021) 149:64–71. doi: 10.1016/j.amjcard.2021.03.022
41. Mangner N, Crusius L, Haussig S, Woitek FJ, Kiefer P, Stachel G, et al. Continued versus interrupted oral anticoagulation during transfemoral transcatheter aortic valve implantation and impact of postoperative anticoagulant management on outcome in patients with atrial fibrillation. Am J Cardiol. (2019) 123:1134–41. doi: 10.1016/j.amjcard.2018.12.042
42. Brinkert M, Mangner N, Moriyama N, Keller LS, Hagemeyer D, Crusius L, et al. Safety and efficacy of transcatheter aortic valve replacement with continuation of vitamin K antagonists or direct oral anticoagulants. JACC Cardiovasc Interv. (2021) 14:135–44. doi: 10.1016/j.jcin.2020.09.062
43. Al-Kassou B, Kandt J, Lohde L, Shamekhi J, Sedaghat A, Tabata N, et al. Safety and efficacy of protamine administration for prevention of bleeding complications in patients undergoing TAVR. JACC Cardiovasc Interv. (2020) 13:1471–80. doi: 10.1016/j.jcin.2020.03.041
44. Zbroński K, Grodecki K, Gozdowska R, Ostrowska E, Wysińska J, Rymuza B, et al. Protamine sulfate during transcatheter aortic valve implantation (PS TAVI) – a single-center, single-blind, randomized placebo-controlled trial. Kardiol Pol. (2021) 79:995–1002. doi: 10.33963/KP.a2021.0070
45. Dangas GD, Lefèvre T, Kupatt C, Tchetche D, Schäfer U, Dumonteil N, et al. Bivalirudin versus heparin anticoagulation in transcatheter aortic valve replacement: the randomized BRAVO-3 trial. J Am Coll Cardiol. (2015) 66:2860–8. doi: 10.1016/j.jacc.2015.10.003
46. Ussia GP, Scarabelli M, Mulè M, Barbanti M, Sarkar K, Cammalleri V, et al. Dual antiplatelet therapy versus aspirin alone in patients undergoing transcatheter aortic valve implantation. Am J Cardiol. (2011) 108:1772–6. doi: 10.1016/j.amjcard.2011.07.049
47. Stabile E, Pucciarelli A, Cota L, Sorropago G, Tesorio T, Salemme L, et al. SAT-TAVI (single antiplatelet therapy for TAVI) study: a pilot randomized study comparing double to single antiplatelet therapy for transcatheter aortic valve implantation. Int J Cardiol. (2014) 174:624–62. doi: 10.1016/j.ijcard.2014.04.170
48. Rodés-Cabau J, Masson JB, Welsh RC, Garcia Del Blanco B, Pelletier M, Webb JG, et al. Aspirin versus aspirin plus clopidogrel as antithrombotic treatment following transcatheter aortic valve replacement with a balloon-expandable valve: the ARTE (aspirin versus aspirin + Clopidogrel following transcatheter aortic valve implantation) randomized clinical trial. JACC Cardiovasc Interv. (2017) 10:1357–65. doi: 10.1016/j.jcin.2017.04.014
49. Brouwer J, Nijenhuis VJ, Delewi R, Hermanides RS, Holvoet W, Dubois CLF, et al. Aspirin with or without clopidogrel after transcatheter aortic-valve implantation. N Engl J Med. (2020) 383:1447–57. doi: 10.1056/NEJMoa2017815
50. Dangas GD, Tijssen JGP, Wöhrle J, Søndergaard L, Gilard M, Möllmann H, et al. A controlled trial of rivaroxaban after transcatheter aortic-valve replacement. N Engl J Med. (2020) 382:120–9. doi: 10.1056/NEJMoa1911425
51. De Backer O, Dangas GD, Jilaihawi H, Leipsic JA, Terkelsen CJ, Makkar R, et al. Reduced leaflet motion after transcatheter aortic-valve replacement. N Engl J Med. (2020) 382:130–9. doi: 10.1056/NEJMoa1911426
52. Park DW, Ahn JM, Kang DY, Kim KW, Koo HJ, Yang DH, et al. Edoxaban versus dual antiplatelet therapy for leaflet thrombosis and cerebral thromboembolism after TAVR: the ADAPT-TAVR randomized clinical trial. Circulation. (2022) 146:466–79. doi: 10.1161/CIRCULATIONAHA.122.059512
53. Jimenez Diaz VA. Short-course dual antiplatelet therapy vs. Oral anticoagulation to prevent cerebral embolism after TAVI: AUREA trial. In: Proceeding of the Transcatheter Cardiovascular Therapeutics Annual Conference. San Francisco, CA (2019).
54. Jochheim D, Barbanti M, Capretti G, Stefanini GG, Hapfelmeier A, Zadrozny M, et al. Oral anticoagulant type and outcomes after transcatheter aortic valve replacement. JACC Cardiovasc Interv. (2019) 12:1566–76. doi: 10.1016/j.jcin.2019.03.003
55. Butt JH, De Backer O, Olesen JB, Gerds TA, Havers-Borgersen E, Gislason GH, et al. Vitamin K antagonists vs. Direct oral anticoagulants after transcatheter aortic valve implantation in atrial fibrillation. Eur Heart J Cardiovasc Pharmacother. (2021) 7:11–9. doi: 10.1093/ehjcvp/pvz064
56. Kosmidou I, Liu Y, Alu MC, Liu M, Madhavan M, Chakravarty T, et al. Antithrombotic therapy and cardiovascular outcomes after transcatheter aortic valve replacement in patients with atrial fibrillation. JACC Cardiovasc Interv. (2019) 12:1580–9. doi: 10.1016/j.jcin.2019.06.001
57. Nijenhuis VJ, Brouwer J, Delewi R, Hermanides RS, Holvoet W, Dubois CLF, et al. Anticoagulation with or without clopidogrel after transcatheter aortic-valve implantation. N Engl J Med. (2020) 382:1696–707. doi: 10.1056/NEJMoa1915152
58. Van Mieghem NM, Unverdorben M, Hengstenberg C, Möllmann H, Mehran R, López-Otero D, et al. Edoxaban versus Vitamin K antagonist for atrial fibrillation after TAVR. N Engl J Med. (2021) 385:2150–60. doi: 10.1056/NEJMoa2111016
59. Collet JP, Van Belle E, Thiele H, Berti S, Lhermusier T, Manigold T, et al. Apixaban vs. standard of care after transcatheter aortic valve implantation: the ATLANTIS trial. Eur Heart J. (2022) 43:2783–97. doi: 10.1093/eurheartj/ehac242
60. Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med. (2010) 363:1597–607. doi: 10.1056/NEJMoa1008232
61. Gilard M, Eltchaninoff H, Iung B, Donzeau-Gouge P, Chevreul K, Fajadet J, et al. Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med. (2012) 366:1705–15. doi: 10.1056/NEJMoa1114705
62. Smith CR, Leon MB, Mack MJ, Miller DC, Moses JW, Svensson LG, et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med. (2011) 364:2187–98. doi: 10.1056/NEJMoa1103510
63. Auffret V, Lefevre T, Van Belle E, Eltchaninoff H, Iung B, Koning R, et al. Temporal trends in transcatheter aortic valve replacement in France: FRANCE 2 to FRANCE TAVI. J Am Coll Cardiol. (2017) 70:42–55.
64. Reardon MJ, Van Mieghem NM, Popma JJ, Kleiman NS, Søndergaard L, Mumtaz M, et al. Surgical or transcatheter aortic-valve replacement in intermediate-risk patients. N Engl J Med. (2017) 376:1321–31. doi: 10.1056/NEJMoa1700456
65. Mack MJ, Leon MB, Thourani VH, Makkar R, Kodali SK, Russo M, et al. Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients. N Engl J Med. (2019) 380:1695–705. doi: 10.1056/NEJMoa1814052
Keywords: transcatheter aortic valve implantation (TAVI), stroke, cerebral embolic protection devices, complication, antithrombotic therapy, aortic stenosis (AS)
Citation: Jimenez Diaz VA, Estevez Loureiro R, Baz Alonso JA, Juan Salvadores P, Bastos Fernandez G, Caneiro Queija B, Veiga Garcia C and Iñiguez Romo A (2022) Stroke prevention during and after transcatheter aortic valve implantation: From cerebral protection devices to antithrombotic management. Front. Cardiovasc. Med. 9:958732. doi: 10.3389/fcvm.2022.958732
Received: 31 May 2022; Accepted: 12 September 2022;
Published: 17 October 2022.
Edited by:
Alessandro Iadanza, Siena University Hospital, ItalyReviewed by:
Matthias Linder, University Medical Center Hamburg-Eppendorf, GermanyFarhad R. Nezami, Brigham and Women’s Hospital and Harvard Medical School, United States
Copyright © 2022 Jimenez Diaz, Estevez Loureiro, Baz Alonso, Juan Salvadores, Bastos Fernandez, Caneiro Queija, Veiga Garcia and Iñiguez Romo. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Victor Alfonso Jimenez Diaz, dmljdG9yLmFsZm9uc28uamltZW5lei5kaWF6QHNlcmdhcy5lcw==