Skip to main content

REVIEW article

Front. Cardiovasc. Med., 26 April 2022
Sec. Structural Interventional Cardiology
This article is part of the Research Topic Insights in Structural Interventional Cardiology: 2022 View all 8 articles

Periprocedural Strategies for Stroke Prevention in Patients Undergoing Transcatheter Aortic Valve Implantation

  • 1Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
  • 2German Centre for Cardiovascular Research (DZHK), Partner Site Hamburg/Lübeck/Kiel, Hamburg, Germany

Cerebrovascular events remain a serious complication in patients undergoing transcatheter aortic valve implantation with an incidence of 2–3% at 30 days. While expanding TAVI to younger low-risk patients, prevention of periprocedural strokes becomes even more important. Different cerebral embolic protection devices have been tested but a clear clinical benefit has not been demonstrated in randomized trials. Due to the multifactorial aetiology with different predisposing factors, stroke prevention should include procedural and periprocedural strategies. This article aims to summarize different approaches and discuss open questions.

Cerebrovascular Events in Patients Undergoing TAVI

Despite continuous improvements in outcomes after transcatheter aortic valve implantation (TAVI), periprocedural strokes remain a devastating complication with severe implications on quality of life, morbidity, and mortality (1, 2). Large trials demonstrated a reduction in periprocedural complications and mortality in the past years, most probably due to procedural and device-related refinements and the expansion of TAVI to younger low-risk patients (38). Subsequently, the PARTNER 3 trial reported an incidence of only 0.6% for strokes within 30 days after TAVI in a highly selected low-risk patient cohort (8) (see Table 1 and Figure 1). But the applicability of these encouraging results to an all-comers patient population remains to be determined. A recent analysis of more than 100,000 patients from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapies Registry reported an overall stroke rate of 2.3% after TAVI in a real-world patient population which remained largely unchanged from 2011 to 2017 (9). Predictors for stroke after TAVI have frequently been investigated with varying and partly conflicting results, underlining the multifactorial aetiology of cerebrovascular events. These included female sex, chronic kidney disease, impaired left-ventricular function, bicuspid aortic valves, aortic stenosis severity, a history of stroke, atrial fibrillation and higher CHA2DS2-Vasc scores, and spontaneous echo contrast in the left atrial appendage for patient-related factors. Procedure-related risk factors were non-transfemoral access, embolization and migration of the transcatheter heart valve, prolonged procedure duration or

TABLE 1
www.frontiersin.org

Table 1. Incidence of stroke events at 30 days after TAVI in randomized controlled trials and registries.

FIGURE 1
www.frontiersin.org

Figure 1. The incidence of stroke within 30 days after TAVI in randomized controlled trials and in a real world clinical registry.

balloon postdilatation. Postprocedural aspects included antithrombotic medication or new-onset atrial fibrillation (1, 1014) (see Figure 2).

FIGURE 2
www.frontiersin.org

Figure 2. Potential risk factors for stroke in patients undergoing TAVI.

Timing and Characterization of Periprocedural Strokes

According to several studies, 91.5–98.3% of cerebrovascular events were of ischemic origin and most strokes became apparent within the first days following TAVI (9, 1518). However, stroke did not necessarily occur during the procedure itself (see Figure 3). Pathology studies identified thrombus, aortic valve tissue, foreign materials, calcium, endothelium, myocardium, and collagen as captured debris in CEP (19). Transcranial Doppler studies detected high-intensity transient signals (HITS) in every TAVI procedure, predominantly during manipulation of the calcified aortic valve during THV positioning and implantation (20, 21). However, the association of HITS and clinically apparent strokes remains to be determined at current. Furthermore, several studies investigated brain lesions after TAVI on DW-MRI (17). Most of these lead to silent brain infarctions (SBI) rather than to clinically apparent strokes. SBI were linked to cognitive decline, perioperative delirium and a composite of overt strokes or TIA after non-cardiac surgery (18). A recently published meta-analysis found SBI in at least 70% of patients following TAVI and linked it to impaired early neurocognitive outcomes (19). The long-term impact of SBI after TAVI remains yet to be determined.

FIGURE 3
www.frontiersin.org

Figure 3. Timing of stroke after TAVI in a randomized controlled trial (18) and several registries (9, 1517).

Cerebral Embolic Protection Devices

While expanding TAVI to younger and lower risk patients, procedural safety—including the prevention of periprocedural strokes in particular—becomes even more important. One approach to reduce procedural cerebrovascular events is to capture or deflect embolic debris from the brain-supplying arteries during TAVI. Several devices for cerebral embolic protection (CEP) have been designed and a significant increase of CEP utilization has recently been described for the United States (2017: 2.8%, 2018: 17.3%) (22). Three devices, that are currently used in clinical routine or under clinical investigation, are discussed briefly:

Sentinel

The SentinelTM (Boston Scientific, Marlborough, Massachusetts) is a CE-marked, FDA-approved, and widely commercially available CEP. It consists of a 6-French compatible dual-filter (140 μm pore size) intra-luminal embolic protection device introduced via the right radial, ulnar, or brachial artery. A proximal filter is positioned in the brachiocephalic artery and a distal filter is deployed in the left carotid artery for the time of the TAVI procedure (see Figure 4A), as previously described (23). At the end of the procedure, both filters are withdrawn.

FIGURE 4
www.frontiersin.org

Figure 4. Current cerebral embolic protection devices. (A) The Sentinel device is a dual- filter-based intra-luminal embolic protection device introduced via the right radial, ulnar, or brachial artery. A proximal filter is placed in the brachiocephalic trunk and a distal filter in the left carotid artery (material provided courtesy of Boston Scientific.© 2022 Boston Scientific Corporation or its affiliates. All rights reserved). (B) The TriGuard3 device is advanced to the aortic arch via the contralateral femoral artery and accommodates a diagnostic pigtail catheter. It covers all three supraaortic vessels to deflect embolic material (material provided courtesy of Keystone Heart, Ltd. All rights reserved). (C) The ProtEmbo device is delivered via the left radial arteria and deployed at the aortic arch roof to cover all three supraaortic vessels and deflect embolic material (material provided courtesy of Protembis GmbH. All rights reserved).

Several studies demonstrated a reduction in the total volume of new cerebral lesions, however, no significant changes in the number of patients with new lesions or the total number of new lesions were observed (2325). In addition, these trials failed to demonstrate a significant reduction of clinically apparent stroke events due to CEP in patients undergoing TAVI (26). On the contrary, a pooled propensity matched pair analysis of randomized and non-randomized linked the SentinelTM CEP to lower rates of strokes within 72 h and mortality at 30 days (27). As results were largely driven by an unusually high stroke rate in the control group of the non-randomized patient population, these findings should be interpreted with caution.

The left vertebral artery arising from the left subclavian artery remains unprotected with the SentinelTM. This may leave a relevant number of patients only partially protected against embolic debris and illustrates a potential limitation of a dual filter CEP-device (15).

To gain additional evidence on the reduction of clinically apparent strokes with CEP during TAVI, the large-scale PROTECTED TAVR (NCT04149535) and British Heart Foundation PROTECT-TAVI (ISRCTN16665769) trials are underway and first results are expected to be presented soon.

TriGUARD3

The TriGUARD3 (Keystone Heart Ltd., Tampa, Florida) is the latest iteration of a 8-French compatible self-positioning deflection filter system (115 μm pore size) that is introduced through the common femoral artery and deployed in the aortic arch (see Figure 4B). By covering all three major cerebral vessels during TAVI, embolic debris is deflected into the descending aorta. The device lumen allows for the placement of a pigtail catheter into the aortic root to guide the TAVI procedure (28). The device received CE-mark in 2020.

After evaluation of the earlier TriGuard™ CEP in the DEFLECT III trial (29), the results of REFLECT II for the TriGUARD3 were recently presented (28). This study was designed to evaluate safety and efficacy of the TriGUARD3 CEP in reducing clinical events and cerebral lesions during TAVI. The trial was prematurely terminated by the sponsor at recommendations of the FDA and Data and Safety Monitoring Board after enrollment of 179 of 225 planned patients. Compared to a historical performance goal, the REFLECT II trial demonstrated the use of the TriGUARD3 to be safe and met the composite 30-day primary safety endpoint according to VARC-2 (30). However, the trial failed to demonstrate efficacy compared with the controls in the pre-specified superiority primary hierarchical composite of all death or stroke at 30 days, NIHSS score worsening, freedom from cerebral ischemic lesions, and total cerebral lesion volume (28). Of note, interaction with the transcatheter heart valve delivery system was reported in 9.6% of cases and complete cerebral coverage was achieved in only 59.7% of patients according to the core laboratory analysis. If complete coverage in all patients may have altered clinical efficacy remains unclear at present.

ProtEmbo

The ProtEmbo Cerebral Protection System (Protembis GmbH, Aachen, Germany) is currently under clinical investigation. It consists of a 6-French compatible implantable aortic filter (pore size 60 μm) designed to cover all three major cerebral arteries in the aortic arch and deflect embolic debris away from the cerebral circulation into the descending aorta during TAVI. It is delivered via the left radial arteria, deployed at the aortic arch roof and retrieved at the end of the procedure (see Figure 4C). A first in human use (31) was the very first case of the PROTEMBO C trial, a European multi-center, single-arm trial evaluating the safety and efficacy in 60 patients undergoing TAVI (NCT04618718). Results of the study are expected to be presented shortly.

Despite promising results in smaller single-center analyses for CEP devices, trials have failed to decrease stroke rates in randomized controlled trials until now. Due to an unclear clinical benefit and additional economic constraints, widespread clinical adoption remains limited at current.

Additional Strategies for Stroke Prevention

The observation that a relevant number of strokes occur early after TAVI but not necessarily during the procedure itself (9, 1518) and that no CEP has yet demonstrated a significant reduction in stroke rate suggests that a sufficient CEP strategy should expand “beyond the procedure itself.” In addition to refined CEP devices, this may include a tailored pharmacological approach to prevent peri- and postprocedural cerebrovascular events by targeting risk factors. Anticoagulation and antithrombotic therapies are a mainstay of this approach.

Periprocedural Anticoagulation

In the absence of specific recommendations for TAVI, non-vitamin K antagonist oral anticoagulants (NOAC) or Vitamin K antagonists (VKA) are frequently switched to low-molecular weight heparin during diagnostic workup in patients with an indication for oral anticoagulation (mostly non-valvular atrial fibrillation) and resumed after the procedure. Several trials demonstrated that uninterrupted anticoagulation throughout cardiovascular procedures, e.g., catheter ablation for atrial fibrillation, was safe and associated with a lower risk for bleeding or stroke (32, 33). First non-randomized data suggest that the continuation of NOAC or VKA may also be safe and effective in patients undergoing TAVI without increased bleeding risk (34). A potential advantage of uninterrupted anticoagulation in these patients, a reduction in peri-procedural strokes, has yet to be shown.

Procedural Anticoagulation and Heparin Reversal

TAVI procedures are performed after anticoagulation with unfractionated heparin to achieve a target activated clotting time of >250 s. At the end of the procedure, protamine is frequently given for heparin reversal to avoid bleeding complications. A recent non-randomized, single center analysis of 873 TAVI procedures found a significant reduction of the primary endpoint (all-cause mortality, major bleeding and life threatening bleeding), of 3.2% after heparin reversal with protamine compared to 8.7% in the control group, driven by less bleeding complications (35). Importantly, no elevated rates of ischemic events were found, However, the limited power and study design may not have been sufficient to adequately evaluate this essential aspect. Whether heparin reversal may increase the risk for ischemic events in patients with a high baseline stroke risk remains unclear at current. Further investigations are warranted to address this aspect and help to further tailor procedural management to the patients’ needs.

Antithrombotic Strategies After TAVI

Following the procedure, sufficient antithrombotic therapies or oral anticoagulation aim to prevent ischemic events early and late after TAVI. However, in this vulnerable patient population, ischemic risk must be weighed against bleeding risk, particularly in the early postprocedural phase. Recently, several trials explored different therapeutic regimen in patients with and without an indication for oral anticoagulation due to atrial fibrillation, the latter of whom are at particular risk for cerebrovascular events during follow-up after TAVI.

In general, oral anticoagulation prevents embolism of fibrin-rich thrombi which mainly occur in areas of low shear stress (e.g., left atrial appendage) while antiplatelet therapy is thought to prevent platelet-rich thrombi developed in areas of high shear stress (e.g., transcatheter heart valve stent frame) (36). Accordingly, adding an antiplatelet agent to oral anticoagulation after TAVI may be beneficial to reduce ischemic events after TAVI. Interestingly, the following trials draw a different picture:

In the POPular TAVI trial aspirin alone was associated with a lower incidence of bleeding (hazard ratio [HR] 0.57; CI 0.42–0.77) and the composite of bleeding or thromboembolic events (HR 0.74; CI 0.57–0.95) at 1 year compared to aspirin plus clopidogrel administered for 3 months (37). In patients with an indication for long-term oral anticoagulation, the incidence of bleeding was lower with oral anticoagulation alone compared to oral anticoagulation and clopidogrel (HR 0.63; CI 0.43–0.90) (38). Importantly, no increased rates of ischemic events were observed in the monotherapy groups of either study arm. Interestingly, although most endpoint-related bleeding events were classified as non-procedural bleedings, Kaplan-Meier event curves diverge in the very early postprocedural period. Timing of initiation and loading dose of antithrombotic medication may have impacted these findings. The ongoing CLOE trial is designed like POPular TAVI but will enroll up to 4,000 patients to investigate the role of clopidogrel on top of aspirin or oral anticoagulation. These results might help us to define a tailored antithrombotic approach.

The ATLANTIS (39) and the ENVISAGE-TAVI AF (40) trials investigated the safety and efficacy of direct oral anticoagulants vs. vitamin K antagonists after TAVI in patients with non-valvular atrial fibrillation. In patients with successful TAVI, edoxaban was non-inferior to VKA for a composite primary outcome of adverse clinical events (death, myocardial infarction, ischemic stroke, systemic embolism, valve thrombosis, and major bleeding). However, the he incidence of major bleeding—mainly driven by gastrointestinal bleeding—was higher in the edoxaban group (hazard ratio 1.40, 95% CI 1.03–1.91) (40). Although superiority for the net clinical benefit was missed in the ATLANTIS trial comparing apixaban with standard of care (VKA or antiplatelet, depending on the indication for oral anticoagulation), event rates for the composite primary and safety bleeding endpoints were similar in both groups (41). The trial design comprising two strata additionally allowed for evaluation of apixaban therapy in patients without an indication for oral anticoagulation (39). However, in line with earlier data from the GALILEO trial (42), ATLANTIS demonstrated an unfavorable risk-benefit ratio for DOAC therapy compared to standard antiplatelets in patients without an indication for oral anticoagulation.

These results led to a de-escalation of antithrombotic regimen after TAVI in most heart teams and a corresponding update in the recent European guidelines on the management of valvular heart disease (43). However, several aspects, including the timing and initiation of antithrombotic therapy, remain unclear at current and deserve further investigation, particularly for the prevention of periprocedural stroke events.

Conclusion

In summary, cerebrovascular events in patients undergoing TAVI remain a multifactorial phenomenon (36) with different predisposing factors according to symptom onset (18). Prevention should include procedural and periprocedural strategies. More randomized data are necessary to clarify open questions concerning the clinical benefit of CEP, anticoagulation and antithrombotic strategies in this setting.

Author Contributions

Both authors listed have made a substantial, direct, and intellectual contribution to the work, and approved it for publication.

Conflict of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s Note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Miller DC, Blackstone EH, MacK MJ, Svensson LG, Kodali SK, Kapadia S, et al. Transcatheter (TAVR) versus surgical (AVR) aortic valve replacement: occurrence, hazard, risk factors, and consequences of neurologic events in the PARTNER trial. J Thorac Cardiovasc Surg. (2012) 143:832–43.e13. doi: 10.1016/j.jtcvs.2012.01.055

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Arnold SVM, Zhang YM, Baron SJM, McAndrew TCP, Kodali SKM, Kapadia SM, et al. Impact of short-term complications on mortality and quality of life after transcatheter aortic valve replacement. J Am Coll Cardiol Interv. (2019) 12:362–9. doi: 10.1016/j.jcin.2018.11.008

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Smith CR, Leon MB, Mack MJ, Miller C, Moses JW, Svensson LG, et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med. (2011) 364:2187–98.

Google Scholar

4. Thyregod HGH, Steinbrüchel DA, Ihlemann N, Nissen H, Kjeldsen BJ, Petursson P, et al. Transcatheter versus surgical aortic valve replacement in patients with severe aortic valve stenosis: 1-year results from the all-comers NOTION randomized clinical trial. J Am Coll Cardiol. (2015) 65:2184–94. doi: 10.1016/j.jacc.2015.03.014

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Leon MB, Smith CR, Mack MJ, Makkar RR, Svensson LG, Kodali SK, et al. Transcatheter or surgical aortic-valve replacement in intermediate-risk patients. N Engl J Med. (2016) 374:1609–20.

Google Scholar

6. Reardon MJ, Van Mieghem NM, Popma JJ, Kleiman NS, Sondergard L. Surgical or transcatheter aortic valve replacement in intermediate-risk patients. N Engl J Med. (2017) 376:1321–31.

Google Scholar

7. Popma JJ, Deeb M, Yakubov SJ, Mumtaz M, Gada H, O’Hair D, et al. Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients. N Engl J Med. (2019) 380:1706–15. doi: 10.1056/NEJMoa1816885

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Mack MJ, Leon MB, Thourani VH, Makkar R, Kodali SK, Russo M, et al. Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients. N Engl J Med. (2019) 380:1695–705.

Google Scholar

9. Huded CP, Tuzcu EM, Krishnaswamy A, Mick S, Kleiman NS, Svensson LG, et al. Association between transcatheter aortic valve replacement and early postprocedural stroke. JAMA. (2019) 321:2306–15.

PubMed Abstract | Google Scholar

10. Auffret V, Regueiro A, Del Trigo M, Abdul-Jawad Altisent O, Campelo-Parada F, Chiche O, et al. Predictors of early cerebrovascular events in patients with aortic stenosis undergoing transcatheter aortic valve replacement. J Am Coll Cardiol. (2016) 68:673–84. doi: 10.1016/j.jacc.2016.05.065

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Linder M, Voigtländer L, Schneeberger Y, Bhadra OD, Grundmann D, Demal TJ, et al. Spontaneous echo contrast, left atrial appendage thrombus and stroke in patients undergoing transcatheter aortic valve implantation. Eurointervention. (2021) 16:1114–22. doi: 10.4244/EIJ-D-20-00743

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Vlastra W, Jimenez-Quevedo P, Tchétché D, Chandrasekhar J Jr, Barbanti M, Kornowski R, et al. Predictors, incidence, and outcomes of patients undergoing transfemoral transcatheter aortic valve implantation complicated by stroke. Circ Cardiovasc Interv. (2019) 12:e007546. doi: 10.1161/CIRCINTERVENTIONS.118.007546

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Hatfield SA, Nores MA, James TM, Rothenberg M, Kapila A, Cubeddu RJ, et al. Predictors and outcomes of stroke after transcatheter aortic valve replacement. J Card Surg. (2020) 35:21–7. doi: 10.1111/jocs.14300

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Makkar RR, Yoon SH, Leon MB, Chakravarty T, Rinaldi M, Shah PB, et al. Association between transcatheter aortic valve replacement for bicuspid vs tricuspid aortic stenosis and mortality or stroke. JAMA. (2019) 321:2193–202. doi: 10.1001/jama.2019.7108

CrossRef Full Text | Google Scholar

15. Linder M, Higgen FL, Voigtländer L, Weimann J, Ludwig S, Waldschmidt L, et al. Stroke events after transcatheter aortic valve implantation: temporal relationships and affected brain regions. Am Heart J. (2022) 247:112–122. doi: 10.1016/j.ahj.2022.02.004

CrossRef Full Text | Google Scholar

16. Tchetche D, Farah B, Misuraca L, Pierri A, Vahdat O, Lereun C, et al. Cerebrovascular events post-transcatheter aortic valve replacement in a large cohort of patients: a FRANCE-2 registry substudy. JACC Cardiovasc Interv. (2014) 7:1138–45. doi: 10.1016/j.jcin.2014.04.018

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Nombela-Franco L, Webb JG, De Jaegere PP, Toggweiler S, Nuis RJ, Dager AE, et al. Timing, predictive factors, and prognostic value of cerebrovascular events in a large cohort of patients undergoing transcatheter aortic valve implantation. Circulation. (2012) 126:3041–53. doi: 10.1161/CIRCULATIONAHA.112.110981

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Kapadia S, Agarwal S, Miller DC, Webb JG, MacK M, Ellis S, et al. Insights into timing, risk factors, and outcomes of stroke and transient ischemic attack after transcatheter aortic valve replacement in the PARTNER trial (placement of aortic transcatheter valves). Circ Cardiovasc Interv. (2016) 9:1–10. doi: 10.1161/CIRCINTERVENTIONS.115.002981

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Kroon H, von der Thusen JH, Ziviello F, van Wiechen M, Ooms J, Kardys I, et al. Heterogeneity of debris captured by cerebral embolic protection filters during TAVI. Eurointervention. (2021) 16:1141–7.

PubMed Abstract | Google Scholar

20. Erdoes G, Basciani R, Huber C, Stortecky S, Wenaweser P, Windecker S, et al. Transcranial doppler-detected cerebral embolic load during transcatheter aortic valve implantation. Eur J Cardio Thorac Surg. (2012) 41:778–84. doi: 10.1093/ejcts/ezr068

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Kahlert P, Al-Rashid F, Döttger P, Mori K, Plicht B, Wendt D, et al. Cerebral embolization during transcatheter aortic valve implantation: a transcranial Doppler study. Circulation. (2012) 126:1245–55. doi: 10.1161/circulationaha.112.092544

CrossRef Full Text | Google Scholar

22. Alkhouli M, Alqahtani F, Harris AH, Hohmann SF, Rihal CS. Early experiencewith cerebral embolic protection during transcatheter aortic valve replacement in the United States. JAMA Intern Med. (2020) 180:783–4. doi: 10.1001/jamainternmed.2019.6767

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Van Mieghem NM, van Gils L, Ahmad H, van Kesteren F, van der Werf HW, Brueren G, et al. Filter-based cerebral embolic protection with transcatheter aortic valve implantation: the randomised MISTRAL-C trial. Eurointervention. (2016) 12:499–507. doi: 10.4244/EIJV12I4A84

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Kapadia SR, Kodali S, Makkar R, Mehran R, Lazar RM, Zivadinov R, et al. Protection against cerebral embolism during transcatheter aortic valve replacement. J Am Coll Cardiol. (2017) 69:367–77. doi: 10.1016/j.jacc.2016.10.023

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Haussig S, Mangner N, Dwyer MG, Lehmkuhl L, Lücke C, Woitek F, et al. Effect of a cerebral protection device on brain lesions following transcatheter aortic valve implantation in patients with severe aortic stenosis the CLEAN-TAVI randomized clinical trial. JAMA. (2016) 316:592–601. doi: 10.1001/jama.2016.10302

PubMed Abstract | CrossRef Full Text | Google Scholar

26. Stachon P, Kaier K, Heidt T, Wolf D, Duerschmied D, Staudacher D, et al. The use and outcomes of cerebral protection devices for patients undergoing transfemoral transcatheter aortic valve replacement in clinical practice. JACC Cardiovasc Interv. (2021) 14:161–8. doi: 10.1016/j.jcin.2020.09.047

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Seeger J, Kapadia SR, Kodali S, Linke A, Wo J, Haussig S, et al. Rate of peri-procedural stroke observed with cerebral embolic protection during transcatheter aortic valve replacement: a patient-level propensity-matched analysis. Eur Heart J. (2019) 40:1334–9. doi: 10.1093/eurheartj/ehy847

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Nazif TM, Moses J, Sharma R, Dhoble A, Rovin J, Brown D, et al. Randomized evaluation of TriGuard 3 cerebral embolic protection after transcatheter aortic valve replacement: REFLECT II. JACC Cardiovasc Interv. (2021) 14:515–27. doi: 10.1016/j.jcin.2020.11.011

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Lansky AJ, Schofer J, Tchetche D, Stella P, Pietras CG, Parise H, et al. A prospective randomized evaluation of the TriGuard TM HDH embolic DEFLECTion device during transcatheter aortic valve implantation: results from the DEFLECT III trial. Eur Heart J. (2015) 36:2070–8. doi: 10.7759/cureus.2494

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Kappetein AP, Head SJ, Généreux P, Piazza N, van Mieghem NM, Blackstone EH, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation. J Am Coll Cardiol. (2012) 60:1438–54.

Google Scholar

31. Jagielak D, Targoński R, Ciećwierz D. First-in-human use of the next-generation protembo cerebral embolic protection system during transcatheter aortic valve-in-valve implantation. Interv Cardiol Rev. (2020) 16:1–4. doi: 10.15420/icr.2021.S1

PubMed Abstract | CrossRef Full Text | Google Scholar

32. Di Biase L, Burkhardt JD, Santangeli P, Mohanty P, Sanchez JE, Horton R, et al. Periprocedural stroke and bleeding complications in patients undergoing catheter ablation of atrial fibrillation with different anticoagulation management. Circulation. (2014) 129:2638–44. doi: 10.1161/CIRCULATIONAHA.113.006426

PubMed Abstract | CrossRef Full Text | Google Scholar

33. Calkins H, Willems S, Gerstenfeld E, Verma A, Schilling R, Hohnloser SH, et al. Uninterrupted dabigatran versus warfarin for ablation in atrial fibrillation. N Engl J Med. (2017) 376:1627–36. doi: 10.1056/nejmoa1701005

CrossRef Full Text | Google Scholar

34. Brinkert M, Mangner N, Moriyama N, Keller LS, Hagemeyer D, Crusius L, et al. Safety and efficacy of transcatheter aortic valve replacement with continuation of vitamin K antagonists or direct oral anticoagulants. JACC Cardiovasc Interv. (2021) 14:134–44. doi: 10.1016/j.jcin.2020.09.062

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Al-Kassou B, Kandt J, Lohde L, Shamekhi J, Sedaghat A, Tabata N, et al. Safety and efficacy of protamine administration for prevention of bleeding complications in patients undergoing TAVR. JACC Cardiovasc Interv. (2020) 13:1471–80. doi: 10.1016/j.jcin.2020.03.041

PubMed Abstract | CrossRef Full Text | Google Scholar

36. Capodanno D, Greco A. Stroke after transcatheter aorticvalve replacement: a multifactorial phenomenon. JACC Cardiovasc Interv. (2019) 12:10–3.

Google Scholar

37. Brouwer J, Nijenhuis VJ, Delewi R, Hermanides RS, Holvoet W, Dubois CLF, et al. Aspirin with or without clopidogrel after transcatheter aortic-valve implantation. N Engl J Med. (2020) 383:1447–57.

Google Scholar

38. Nijenhuis VJ, Brouwer J, Delewi R, Hermanides RS, Holvoet W, Dubois CLF, et al. Anticoagulation with or without clopidogrel after transcatheter aortic-valve implantation. N Engl J Med. (2020) 382:1696–707. doi: 10.1056/NEJMoa1915152

PubMed Abstract | CrossRef Full Text | Google Scholar

39. Collet JP, Berti S, Cequier A, Van Belle E, Lefevre T, Leprince P, et al. Oral anti-Xa anticoagulation after trans-aortic valve implantation for aortic stenosis: the randomized ATLANTIS trial. Am Heart J. (2018) 200:44–50. doi: 10.1016/j.ahj.2018.03.008

PubMed Abstract | CrossRef Full Text | Google Scholar

40. Van Mieghem NM, Unverdorben M, Hengstenberg C, Möllmann H, Mehran R, López-Otero D, et al. Edoxaban versus vitamin K antagonist for atrial fibrillation after TAVR. N Engl J Med. (2021) 385:2150–60.

Google Scholar

41. Collet JP, Belle E Van, Thiele H, Jacques Portal J, Vicaut E, Montalescot G, et al. Anti-Thrombotic Strategy to Lower all Cardiovascular and Neurologic Ischemic and Hemorrhagic Events after Trans- Aortic Valve Implantation for Aortic Stenosis: A Randomized, Open-Label, Phase 3 Trial. (n.d.). Available online at: https://www.acc.org/-/media/Clinical/PDF-Files/Approved-PDFs/2021/05/11/ACC21/15May-Sat/9amET-ATLANTIS-acc-2021.pdf (accessed March 3, 2022).

Google Scholar

42. Dangas GD, Tissen JGP, Wöhrle J, Søndergaard L, Gilard M, Möllmann H, et al. A controlled trial of rivaroxaban after transcatheter aortic-valve replacement. New Engl J Med J Med. (2020) 382:120–9.

Google Scholar

43. Vahanian A, Beyersdorf F, Praz F, Milojevic M, Baldus S, Bauersachs J, et al. 2021 ESC/EACTS guidelines for the management of valvular heart disease: developed by the task force for the management of valvular heart disease of the European society of cardiology (ESC) and the European association for cardio-thoracic surgery (EACTS). Eur Heart J. (2021) 43:561–632. doi: 10.1093/eurheartj/ehac051

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: anticoagulation, antithrombotic therapy, cerebrovascular embolic protection, stroke, TAVI

Citation: Linder M and Seiffert M (2022) Periprocedural Strategies for Stroke Prevention in Patients Undergoing Transcatheter Aortic Valve Implantation. Front. Cardiovasc. Med. 9:892956. doi: 10.3389/fcvm.2022.892956

Received: 09 March 2022; Accepted: 15 March 2022;
Published: 26 April 2022.

Edited by:

Marco Zimarino, Asl Lanciano Vasto Chieti, Italy

Reviewed by:

Tiziana Attisano, Ospedali Riuniti San Giovanni di Dio e Ruggi d’Aragona, Italy
Ran Kornowski, Rabin Medical Center, Israel

Copyright © 2022 Linder and Seiffert. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Moritz Seiffert, m.seiffert@uke.de

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.