Skip to main content

SYSTEMATIC REVIEW article

Front. Cardiovasc. Med., 11 February 2022
Sec. Cardiac Rhythmology
This article is part of the Research Topic Conduction System Pacing: What's missing for the paradigm shift? View all 18 articles

Clinical Outcomes Associated With His-Purkinje System Pacing vs. Biventricular Pacing, in Cardiac Resynchronization Therapy: A Meta-Analysis

\nYang GuiYang Gui1Lifang YeLifang Ye2Liuyang WuLiuyang Wu2Haohui MaiHaohui Mai2Qiqi YanQiqi Yan2Lihong Wang
Lihong Wang2*
  • 1BengBu Medical College, Bengbu, China
  • 2Department of Cardiovascular Medicine, Zhejiang Provincial People's Hospital, People's Hospital of Hangzhou Medical College, Hangzhou, China

Aims: His-Purkinje system pacing has recently emerged as an alternative to biventricular pacing (BIVP) in cardiac resynchronization therapy (CRT). The aim of this study was to conduct a meta-analysis comparing the clinical outcomes associated with His-Purkinje system pacing (HPSP) vs. BIVP in patients with heart failure. There is also a comparison of clinical outcomes of His-bundle pacing (HBP) and left bundle branch pacing (LBBP) in the His-Purkinje system.

Methods: We searched the Cochrane Library, Embase, and PubMed, for studies published between January 2010 and October 2021 that compared the clinical outcomes associated with HPSP vs. BIVP and HBP vs. LBBP in HPSP in patients who underwent CRT. The pacing threshold, R-wave amplitudes, QRS duration, New York Heart Association functional (NYHA), left ventricular ejection fraction (LVEF), and LV end-diastolic diameter (LVEDD) of heart failure, at follow-up, were extracted and summarized for meta-analysis.

Results: A total of 18 studies and 1517 patients were included in our analysis. After a follow-up period of 9.3 ± 5.4 months, the HPSP was found to be associated with shorter QRS duration in the CRT population compared to that in the BIVP (SMD, −1.17; 95% CI, −1.56 to −0.78; P < 0.00001; I2 = 74%). No statistical difference was verified between HBP and LBBP on QRS duration (SMD, 0.04; 95% CI, −0.32 to 0.40; P = 0.82; I2 = 84%). In the comparison of HPSP and BIVP, the LBBP subgroup showed improved LVEF (SMD, 0.67; 95% CI, 0.42–0.91; P < 0.00001; I2 = 0%), shorter LVEDD (SMD, 0.59; 95% CI, 0.93–0.26; P = 0.0005; I2 = 0%), and higher New York Heart Association functional class (SMD, −0.65; 95% CI, −0.86 to −0.43; P < 0.00001; I2 = 45%). In terms of pacing threshold and R-wave amplitude clinical outcomes, LBBP has a lower pacing threshold (SMD, 1.25; 95% CI, 1.12–1.39; P < 0.00001; I2 = 47%) and higher R-wave amplitude (MD, −7.88; 95% CI, −8.46 to −7.31; P < 0.00001; I2 = 8%) performance compared to HBP.

Conclusion: Our meta-analysis showed that the HPSP produced higher LVEF, shorter QRS duration, and higher NYHA functional class in the CRT population than the BIVP as observed on follow-up. LBBP has a lower pacing threshold and higher R-wave amplitude. HPSP may be a new and promising alternative to BIVP in the future.

Highlights

- QRS duration was shorter in His-Purkinje system pacing than in biventricular pacing.

- The left bundle branch pacing group in His-Purkinje system pacing is associated with improved LVEF, increased LVEDD, and higher NYHA functional class.

- In patients with heart failure who underwent cardiac resynchronization therapy, the His-Purkinje system pacing showed better results than biventricular pacing.

- LBBP has a lower pacing threshold and higher R-wave amplitude.

Introduction

Cardiac resynchronization therapy (CRT) is used to treat patients with heart failure (HF), and ventricular systolic dyssynchrony. By electrically activating the heart in a coordinated manner, CRT can successfully restore mechanical synchrony. Traditionally, this therapy has been implemented using biventricular pacing. Studies have shown that biventricular pacing (BIVP) can improve symptoms, reduce hospitalization times, and prolong the survival of patients (14). However, multiple clinical trials have demonstrated that 30-40% of patients showed no changes after BIVP-based CRT (510).

In 2015, a crossover study by Lustgarten et al. showed that His-bundle pacing (HBP) can achieve clinical outcomes comparable to BIVP (11). Similarly, several other studies have suggested that HBP may be a suitable alternative for CRT non-responders and patients with failed left ventricle (LV) lead placement (1214); some of these studies have even recommended HBP as frontline therapy for heart failure and left ventricle dyssynchrony (1214). In addition, recent guidelines by the American College of Cardiology/American Heart Association have assigned HBP a grade II in terms of recommendation for replacing right ventricular pacing in patients who need chronic ventricular pacing with reduced LV ejection fraction (LVEF; 36–50%) (11, 15). More recently, however, studies compared HPSP with BIVP pacing and evaluated the potential advantages in CRT. The HPSP is characterized by a generation of strategies that can mimic pacing or fully restore normal atrioventricular (AV) activation, ensuring optimal clinical outcomes; it involves left bundle branch pacing (LBBP) and HBP. LBBP can correct left bundle branch blocks (LBBB) and, thus, lead to improvement of cardiac electrical dyssynchrony compared with conventional right ventricular apical pacing (16). LBBP produces a lower pacing capture threshold and higher R-wave amplitude than HBP and stimulates the conduction system of the heart as well as the deep septal myocardium (17, 18). The role of His-Purkinje conduction system is usually to produce true cardiac resynchronization. In contrast, some studies have concluded that ventricular mechanical synchronization parameters are significantly better in patients with HBP than in patients with right ventricular septal pacing (RVSP) (19, 20).

HBP is the most physiological pacing strategy for restoring normal ventricular excitation patterns (21). In the case of His bundle pacing (HBP), HBP corrects complete left bundle branch block (CLBBB) by activating the heart's intrinsic conduction system and thus providing natural ventricular excitation propagation (22, 23). There are currently no publications that comprehensively analyze and summarize the data generated from clinical trials that have evaluated the influence of HPSP therapy. Currently for the His-Purkinje conduction system, both the comparison with conventional BIVP pacing and the advantages and disadvantages of HBP vs. LBBP pacing in the His-Purkinje conduction system have a great role for CRT. Therefore, this study aimed to compare HPSP and BIVP in clinical outcomes in patients with HF and to conduct a meta-analysis.

Methods

This study protocol has been published previously in PROSPERO (CRD42021235736).

Search Strategy

The meta-analysis was conducted according to the meta-analysis statement and the preferred reporting items for systematic reviews (24). We selected relevant studies published between January 2010 and October 2021 by searching PubMed, EMBASE, and Cochrane Library. Our search did not have any language restrictions. The search terms were “His bundle pacing” OR “Left branch bundle pacing” OR “biventricular pacing” AND “Cardiac Resynchronization Therapy.” In addition, we also searched the list of references in the studies retrieved by our search criteria.

Study Eligibility Criteria

We included randomized clinical trials (RCTs) and observational studies which examined patients with HF requiring CRT. Specifically, studies were included if they (i) were RCTs, (ii) were observational studies, or (iii) reported empirical data regarding clinical outcomes, including Pacing threshold, R-wave amplitudes, QRS duration, LVEF, LV end-diastolic diameter (LVEDD), and New York Heart Association (NYHA) class of HF. Studies were excluded if they (i) were missing text, (ii) reported results from a previously included study, (iii) did not include or directly study CRT, or (iv) had missing data or insufficient original data.

Data Extraction

Two reviewers independently extracted data from the included RCTs and observational studies; disagreements were resolved by consensus through discussion. We recorded the following information from the included RCTs and observational studies: duration of follow-up, number of participants, and year of publication, and study design. We also extracted information on pacing threshold, R-wave amplitudes QRS duration, LVEF, LVEDD, and NYHA HF class.

Quality Assessment

Two reviewers independently assessed the RCTs included in this study using the Jadad scoring system (25), which assesses the methodological quality of RCTs. Investigations that received Jadad scores below 4 (out of a possible 5) were classified as low-quality, while those that scored ≥4 were deemed high-quality. Among the included observational studies, for the retrospective studies and cohort studies, assessment of using the Newcastle Ottawa scale (NOS) (26) to performed the quality of nonrandomized studies. Investigations that received NOS scores below 6 (out of a possible 9) were classified as low-quality, while those that scored ≥6 were deemed high-quality. When the format of the required data for inclusion was not suitable for the meta-analysis, the primary authors and publishing journals were contacted by email to access unpublished data.

Statistical Analyses

For all statistical analyses, RevMan 5.3 software (27) was used. A comprehensive analysis of individual studies was done to compare the different effects of His-Purkinje system pacing and BIVP in patients with HF. We assessed statistical heterogeneity with the Q statistic from the chi-square test and P < 0.05 represented a significant result. We dequantified the proportion of variation using the I2 statistics between studies due to heterogeneity. It was considered that there was little heterogeneity between studies if P ≥ 0.1, or I2 ≤ 50%; P < 0.1, or I2 > 50% indicated moderate heterogeneity, and I2 > 75% indicated considerable heterogeneity, I2 ≤ 50% used fixed-effects model and I2 > 50% used-random effects model. A subgroup analysis was attempted to find the source of heterogeneity. To analyze the literature for the presence or absence of publication bias, we used funnel plots. The mean and standard deviation were reported for continuous variables. Review Manager V5.3 (27) was used for all data processing analyses.

Results

Study and Patient Characteristics

Initially, a total of 425 articles were retrieved. Out of which, 32 articles were retained for full article evaluation by reviewing the study titles with the abstracts. Duplicate reviews and duplicate case reports with non-relevant studies were excluded. These 32 studies underwent a thorough screening process as shown in Figure 1. Following the screening, 18 studies were included in our analysis; four of these were RCT studies, while 14 were observational studies. Ten of them are the comparison of HPSP with BIVP and eight are the comparison of HBP with LBBP in HPSP. Further details regarding the studies analyzed are shown in Table 1. The 18 included studies (11, 2945), which were RCTs and observational studies, were scored using the Jadad scoring system and the NOS quality assessment system, as shown in Figures 2A,B.

FIGURE 1
www.frontiersin.org

Figure 1. A flow diagram showing how articles were selected for analysis, Moher et al. (28).

TABLE 1
www.frontiersin.org

Table 1. Basic characteristics of included studies analyzed during this study.

FIGURE 2
www.frontiersin.org

Figure 2. (A) Four of the included RCT studies were using scoring system at risk of bias. (B) Fourteen of the included studies using the Newcastle Ottawa scale (NOS).

QRS Duration

The heterogeneity between individual studies was tested by analyzing differences in the QRS duration in 482 patients from 10 studies (I2 = 74%). The random-effect model was used. As shown in Figure 3A, patients treated with the His-Purkinje system pacing had shorter QRS duration than those treated with BIVP (SMD, −1.17; 95% CI, −1.56 to −0.78; P < 0.00001; I2 = 74%; Figure 3A). Although the heterogeneity test between the 10 studies indicated that there was moderate heterogeneity, sensitivity analysis showed that the results did not change significantly among all the studies included.

FIGURE 3
www.frontiersin.org

Figure 3. (A) QRS duration in patients receiving HPSP therapy vs. BIVP therapy. (B) QRS duration in patients receiving LBBP vs. HBP [(A) top table; (B) bottom table].

The eight included papers on HBP and LBBP directly compared clinical outcomes. There was no significant difference between LBP and LBBP in the QRS duration index (SMD, 0.04; 95% CI, −0.32 to 0.40; P = 0.82; I2 = 84%; Figure 3B). HPSP produced a reduction in QRS duration compared to the BIVP group, but no differences were found when comparing within groups.

LV Function Assessment

LVEF was analyzed by fixed models in 436 patients from nine studies. The LVEF fraction was higher in the HPSP group, compared with that in the BIVP group (SMD, 0.47; 95% CI, 0.29–0.65; P < 0.00001; I2 = 42%; Figure 4A).There was little heterogeneity among the study results (P < 0.00001; I2 = 42%). Three studies were included in the evaluation of LVEDD differences. We used the fixed-effects model because of the heterogeneity between the studies (I2 = 0%). When compared with BIVP, the His-Purkinje system pacing indicated better performance (SMD, 0.59; 95% CI, 0.93–0.26; P = 0.0005; I2 = 0%; Figure 4B).

FIGURE 4
www.frontiersin.org

Figure 4. (A) LVEF. (B) LVEDD. Left ventricular function pacing of the His-Purkinje system is required in patients with HF therapy vs. biventricular pacing therapy. Both LVEF and LVEDD were measured by echocardiography.

NYHA Functional Class

Of the eight included studies, seven of them reported a functionally relevant improvement analysis. We used the random-effect model because of the heterogeneity between the studies (I2 = 45%). Compared with BIVP, His-Purkinje system pacing indicated better performance (SMD, −0.65; 95% CI, −0.86 to −0.43; P < 0.00001; I2 = 45%, Figure 5). No evidence of publication bias was found, after passing the inspection of the corresponding funnel plots.

FIGURE 5
www.frontiersin.org

Figure 5. New York Heart Association functional class in patients receiving His-Purkinje system pacing therapy vs. biventricular pacing therapy.

Pacing Threshold

In the eight papers we adopted on the direct comparison between LBBP and HBP, the pacing threshold indexes all showed a great advantage of LBBP (SMD, 1.25; 95% CI, 1.12–1.39; P < 0.00001; I2 = 47%, Figure 6).

FIGURE 6
www.frontiersin.org

Figure 6. Pacing thresholds in patients receiving comparison between HBP and LBBP in His-Purkinje system.

R-wave Amplitudes

Seven of the eight included papers reported R-wave amplitudes, with LBBP reflecting considerable R-wave amplitudes compared to HBP (MD, −7.88; 95% CI, −8.46 to −7.31; P < 0.00001; I2 = 8%, Figure 7).

FIGURE 7
www.frontiersin.org

Figure 7. R-wave amplitudes in patients receiving comparison between HBP and LBBP in His-Purkinje system.

Discussion

This systematic review and meta-analysis identified 18 trials with a total of 1,517 participants and compared cardiac electrophysiology and cardiac function in HPSP and BIVP and in HBP and LBBP. Ultimately, we concluded that HPSP resulted in a favorable improvement in QRS duration in patients with HF, while LBBP improved LV function and improved NYHA functional class in CRT candidates. When HBP and LBBP were directly compared in terms of the His-Purkinje system, LBBP demonstrated a lower pacing threshold and higher R-wave amplitude than HBP.

Several randomized controlled trials and observational studies have shown that long-term differences in LVEF have the potential to lead to interventricular dyssynchrony. One of the parameters of interventricular dyssynchrony is QRS duration (2933, 35, 46). In the present study, the HPSP group performed better than the BIVP group in terms of QRS duration. It can also be argued that LBBP or HBP may produce better electromechanical synchronization and thus induce more synchronized LV contractions. In our study, HPSP improved the QRS duration by 22.23 ms relative to BIVP. Moreover, no difference in QRSd was found between LBBP and HBP (P = 0.82).

Sheng et al. (41) also confirmed that HBP and LBBP produce similar QRSd. During atrial fibrillation, LBBP is equally as viable as HBP. A unique finding of Sheng's (41) study was the difference in interventricular synchrony between HBP and LBBP. In contrast, the unipolar configuration of LBBP produced a slightly later contraction of the right ventricular myocardium compared to that produced by HBP. In bradycardic patients requiring CRT, HBP and LBBP led to similar QRSd and implantation success rates and shorter procedure and fluoroscopy times. However, the study (41) also noted a significantly lower pacing threshold for LBBP and a higher R-wave amplitude at implantation and at the 3-month follow-up. Moreover, LBBP has better clinical feasibility compared to the HBP. This is consistent with our findings comparing HBP with LBBP, in which LBBP improved pacing thresholds by an average of 0.62 ms over HBP and by 7.88 mv in R-wave amplitude. Chen et al. (47) demonstrated the clinical feasibility of LBBP by using a transventricular septal approach. Massing et al. (48) suggested that LBBP could directly branch out from the branch point of the His bundle in the cardiac structure under the endocardium on the left side of the septum, thus forming a reticular structure, so that the left bundle branch can be paced faster than by HBP through the septal approach. This may explain the better pacing threshold and R-wave amplitude of LBBP compared with HBP. Zhang et al. (49) attributed the narrow QRS pattern during LBBP to the activation of the right bundle branch of the ventricle by electrophysiological retrograde conduction, which forms a connection with intrinsic conduction fusion. Huang et al. (50) had a higher success rate and a stable lower pacing threshold with LBBP than HBP and a better perception of ventricular excitation (R-wave amplitude).

LBBP is now the preferred conduction system pacing modality for patients with pacing indications (20, 21). Li et al. (21) reported on LBBP in 33 patients with AVB and found that it has a success rate of more than 90%, produces low and stable thresholds, maintains LV synchronization, and has few complications. The current potential hypothesis is that LBBP further enriches physiological pacing and may even be more applicable to patients with AVB. Furthermore, Vinther et al. (37) found that His bundle improved ventricular function and quality of life, but this was at the cost of a higher pacing threshold. Hou et al. (39) found that left bundle branch pacing produced higher R-wave amplitude than HBP and lower capture threshold stability parameters than HBP. Qian et al. (44) concluded that His-Purkinje system pacing produces good electrical synchronization and narrow QRS time frames and that it has beneficial effects in maintaining cardiac function. In contrast, left bundle branch pacing showed superior lead stability in terms of pacing parameters. Ye et al. (45) found that both HBP and LBBP can be successfully implemented in the same patient with atrial fibrillation and that LBBP produces better and more stable parameters compared to HBP. Patients with AF with HF and arrhythmias benefit more from HPSP in terms of physical performance and echocardiographic parameters.

Overall, we concluded that HPSP produced better electromechanical synchronization than BIVP; further, when comparing HPSP within groups, LBBP had higher success rates, lower pacing thresholds, and higher R-wave amplitudes compared to HBP.

HPSP, a physiological pacing modality that directly stimulates the conduction system of the heart and maintains synchronization of ventricular electrical activation has produced better results compared to BIVP in clinical practice (41, 45). Lustgarten et al. (11) summarized the clinical outcome data from a 2015 study of 12 patients with a mean baseline LVEF of 26%; at the 6-month follow-up, HBP was shown to improve by 32% and BIVP by 31% (P = 0.043 and P = 0.02, respectively); the baseline NYHA grades for HBP and BIVP improved from 2.9 to 1.9 (P < 0.01 and P < 0.01, respectively). The multicenter 2019 RCT His-SYNC study by Upadhyay et al. (33) included 41 patients from 7 centers who met the criteria indications for CRT; 20 and 21 of these patients were randomized to the BIVP CRT and His CRT groups, respectively. Patients in both groups showed a significant improvement in LVEF after 6.2 months of follow-up, when compared with the baseline values. The median LVEF increased from 28.0 to 34.6% (P < 0.001) in patients treated with HBP CRT, whereas it increased from 27.7 to 32.0% (P < 0.001) in those treated with BIVP CRT. To determine the difference in LV function by pacing modality, we also compared LVEF, LVEDD, and NYHA. In our meta-analysis, LVEF was significantly improved in both groups compared with the baseline values at the 6-month follow-up. HPSP showed a 3.91% improvement in LVEF, a 5.36 mm reduction in LVEDD, and a 0.44 grade reduction in NYHA compared with BIVP. Clinical outcomes were similar for BIVP and HBP. In patients with HF, cardiac resynchronization can be achieved by pacing the His-Purkinje system to correct LBBB. Theoretically, HPSP may be more physiologically consistent than BIVP because the latter still relies on stimuli that do not propagate through the normal conduction system but through the myocardium. The relatively small number of 18 studies analyzed may have influenced the results. Larger RCTs are needed to validate the relationship between His-Purkinje system pacing and BIVP.

In summary, we conclude that the His-Purkinje system produces higher LVEF, shorter QRS duration, and higher NYHA functional class in the CRT group compared to BIVP in pacing therapy overall. When comparing HPSP systems within groups, LBBP had a higher success rate, a lower pacing threshold, and higher R-wave amplitude compared to HBP. HPSP may be a new and promising alternative to BIVP in the future.

Study Limitations

This meta-analysis has several limitations. First, is a bias due to the small number of included relevant RCTs and the fact that most studies (2932, 34, 35, 3845) were post-hoc analyses. This bias may have influenced the conclusions of the present study. Second, the length of follow-up in the included literature takes longer to justify the results. Third, this study did not include data on mortality or cardiovascular hospitalization. Fourth, the complications after different pacing procedures are not discussed.

Conclusion

In conclusion, the HPSP can produce shorter QRS duration, higher LVEF, and higher NYHA functional class in the CRT population compared with BIVP as observed by follow-up. HPSP may be a new and promising alternative to BIVP in the future. LBBP has a lower pacing threshold and higher R-wave amplitude. Considering the clinical significance of pacing therapies, RCTs are required to further evaluate the efficacy of HPSP compared with BIVP in achieving CRT.

Data Availability Statement

The original contributions presented in the study are included in the article/supplementary material, further inquiries can be directed to the corresponding author.

Author Contributions

All authors listed have made a substantial, direct, and intellectual contribution to the work and approved it for publication.

Funding

This study was supported by the National Natural Science Foundation of China under Grant No. 81670447; the National Natural Science Foundation of Zhejiang Province under Grant No. LY15H020006; Zhejiang Province Key Subject of Medicine (Neurological Rehabilitation) and the Traditional Chinese Medicine Program of Zhejiang Provincial under Grant No. 2017ZZ001; the Zhejiang Provincial Health Commission Project under Grant No. 2017KY559; the National Natural Science Foundation of Zhejiang Province under Grant No. LY19H070003. LW is sponsored by Zhejiang Provincial Program for the Cultivation of High-Level Innovative Health Talents.

Conflict of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict ofinterest.

Publisher's Note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Acknowledgments

The author wishes to thank all those who have helped.

References

1. Abraham WT, Fisher WG, Smith AL, Delurgio DB, Leon AR, Loh E, et al. Cardiac resynchronization in chronic heart failure. N Engl J Med. (2002) 346:1845–53. doi: 10.1056/NEJMoa013168

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Cleland JG, Daubert JC, Erdmann E, Freemantle N, Gras D, Kappenberger L, et al. The effect of cardiac resynchronization on morbidity and mortality in heart failure. N Engl J Med. (2005) 352:1539–49. doi: 10.1056/NEJMoa050496

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Daubert C, Gold MR, Abraham WT, Ghio S, Hassager C, Goode G, et al. Prevention of disease progression by cardiac resynchronization therapy in patients with asymptomatic or mildly symptomatic left ventricular dysfunction: insights from the European cohort of the REVERSE (resynchronization reverses remodeling in systolic left ventricular dysfunction) trial. J Am Coll Cardiol. (2009) 54:1837–46. doi: 10.1016/j.jacc.2009.08.011

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Moss AJ, Hall WJ, Cannom DS, Klein H, Brown MW, Daubert JP, et al. Cardiacresynchronization therapy for the prevention of heart-failure events. N Engl J Med. (2009) 361:1329–38. doi: 10.1056/NEJMoa0906431

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Carluccio E, Biagioli P, Alunni G, Murrone A, Zingarini G, Coiro S, et al. Noncardiac factors for prediction of response to cardiac resynchronization therapy: the value of baseline, and of serial changes, in red cell distribution width. Int J Cardiol. (2017) 243:347–53. doi: 10.1016/j.ijcard.2017.05.123

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Kydd AC, Khan FZ, Ring L, Pugh PJ, Virdee MS, Dutka DP. Development of a multiparametric score to predict left ventricular remodelling and prognosis after cardiac resynchronization therapy. Eur J Heart Fail. (2014) 16:1206–13. doi: 10.1002/ejhf.167

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Martin CA, Gajendragadkar PR, Pugh PJ. Unusual cause of poor response to cardiac resynchronisation therapy. Heart. (2014) 100:514. doi: 10.1136/heartjnl-2013-305340

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Thompson N, Derval N. Left ventricular endocardial stimulation in patients with a poor response to cardiac resynchronization therapy: what is next? JACC Clin Electrophysiol. (2016) 2:810–1. doi: 10.1016/j.jacep.2016.06.003

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Wang J, Su Y, Bai J, Wang W, Qin S, Ge J. Elevated pulmonary artery pressure predicts poor outcome after cardiac resynchronization therapy. J Interv Card Electrophysiol. (2014) 40:171–8. doi: 10.1007/s10840-014-9890-2

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Werys K, Petryka-Mazurkiewicz J, Blaszczyk L, Misko J, Spiewak M, Malek LA, et al. Cine dyscontractility index: a novel marker of mechanical dyssynchrony that predicts response to cardiac resynchronization therapy. J Magn Reson Imaging. (2016) 44:1483–92. doi: 10.1002/jmri.25295

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Lustgarten DL, Crespo EM, Arkhipova-Jenkins I, Lobel R, Winget J, Koehler J, et al. His-bundle pacing versus biventricular pacing in cardiac resynchronization therapy patients: a crossover design comparison. Heart Rhythm. (2015) 12:1548–57. doi: 10.1016/j.hrthm.2015.03.048

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Sharma PS, Dandamudi G, Herweg B, Wilson D, Singh R, Naperkowski A, et al. Permanent His-bundle pacing as an alternative to biventricular pacing for cardiac resynchronization therapy: a multicenter experience. Heart Rhythm. (2018) 15:413–20. doi: 10.1016/j.hrthm.2017.10.014

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Ajijola OA, Upadhyay GA, Macias C, Shivkumar K, Tung R. Permanent His-bundle pacing for cardiac resynchronization therapy: initial feasibility study in lieu of left ventricular lead. Heart Rhythm. (2017) 14:1353–61. doi: 10.1016/j.hrthm.2017.04.003

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Shan P, Su L, Zhou X, Wu S, Xu L, Xiao F, et al. Beneficial effects of upgrading to His bundle pacing in chronically paced patients with left ventricular ejection fraction <50%. Heart Rhythm. (2018) 15:405–12. doi: 10.1016/j.hrthm.2017.10.031

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Kusumoto FM, Schoenfeld MH, Barrett C, Edgerton JR, Ellenbogen KA, Gold MR, et al. ACC/AHA/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delay: Executive summary—a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines, and the Heart Rhythm Society. J Am Coll Cardiol. (2018) 74:932–87. doi: 10.1016/j.jacc.2018.10.043

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Zhang J, Wang Z, Cheng L, Zu L, Liang Z, Hang F, et al. Immediate clinical outcomes of left bundle branch area pacing vs conventional right ventricular pacing. Clin Cardiol. (2019) 42:1–6. doi: 10.1002/clc.23215

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Vigmond EJ, Stuyvers BD. Modeling our understanding of the His-Purkinje system. Prog Biophys Mol Biol. (2016) 120:179–88. doi: 10.1016/j.pbiomolbio.2015.12.013

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Zhang J, Guo J, Hou X, Wang Y, Qian Z, Li K, et al. Comparison of the effects of selective and non-selective his bundle pacing on cardiac electrical and mechanical synchrony. Europace. (2018) 20:1010–7. doi: 10.1093/europace/eux120

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Thosani AJ, Liu E, Shaw G, Belden W, Chenarides J. Rapid reversal of right ventricular pacing-induced cardiomyopathy by His bundle pacing. Heart Rhythm Case Rep. (2017) 3:189–91. doi: 10.1016/j.hrcr.2017.01.004

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Vijayaraman P, Subzposh FA, Naperkowski A, Panikkath R, John K, Mascarenhas V, et al. Prospective evaluation of feasibility, electrophysiologic and echocardiographic characteristics of left bundle branch area pacing. Heart Rhythm. (2019) 16:1774–82. doi: 10.1016/j.hrthm.2019.05.011

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Li X, Li H, Ma W, Ning X, Liang E, Pang K, et al. Permanent left bundle branch area pacing for atrioventricular block: feasibility, safety, and acute effect. Heart Rhythm. (2019) 16:1766–73. doi: 10.1016/j.hrthm.2019.04.043

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Sharma PS, Vijayaraman P, Ellenbogen KA. Permanent his bundle pacing: shaping the future of physiological ventricular pacing. Nat Rev Cardiol. (2020) 17:22–36. doi: 10.1038/s41569-019-0224-z

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Huang W, Su L, Wu S, Xu L, Xiao F, Zhou X, et al. Benefits of permanent his bundle pacing combined with atrioventricular node ablation in atrial fibrillation patients with heart failure with both preserved and reduced left ventricular ejection fraction. J Am Heart Assoc. (2017) 6:e005309. doi: 10.1161/JAHA.116.005309

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Liberati A, Altman DG, Tetzlaff J, Mulrow G, Gøtzsche PC, Ioannidis JPA et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. PLoS Med. (2009) 6:e1000100. doi: 10.1371/journal.pmed.1000100

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Jadad AR, Moore RA, Carroll D, Jenkinson C, Reynolds DJ, Gavaghan DJ, et al. Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials. (1996) 17:1e12. doi: 10.1016/0197-2456(95)00134-4

PubMed Abstract | CrossRef Full Text | Google Scholar

26. Stang A. Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in metaanalyses. Eur J Epidemiol. (2010) 25:603–5. doi: 10.1007/s10654-010-9491-z

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Review Manager (RevMan) [Computer program]. Version 5.3. Copenhagen: The Nordic Cochrane Centre, The Cochrane Collaboration (2014).

Google Scholar

28. Moher D Liberati A Tetziaff J Altman DG The The PRISMA Group (2009). Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement. PLoS Med 6(7): e1000097. doi: 10.1371/journal.pmed1000097

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Li X, Qiu C, Xie R, Ma W, Wang Z, Li H, et al. Left bundle branch area pacing delivery of cardiac resynchronization therapy and comparison with biventricular pacing. ESC Heart Fail. (2020) 7:1711–22. doi: 10.1002/ehf2.12731

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Wang Y, Gu K, Qian Z, Hou X, Chen X, Qiu Y, et al. The efficacy of left bundle branch area pacing compared with biventricular pacing in patients with heart failure: a matched case-control study. J Cardiovasc Electrophysiol. (2020) 31:2068–77. doi: 10.1111/jce.14628

PubMed Abstract | CrossRef Full Text | Google Scholar

31. Guo J, Li L, Xiao G, Ye T, Huang X, Meng F, et al. Remarkable response to cardiac resynchronization therapy via left bundle branch pacing in patients with true left bundle branch block. Clin Cardiol. (2020) 43:1460–8. doi: 10.1002/clc.23462

PubMed Abstract | CrossRef Full Text | Google Scholar

32. Wu S, Su L, Vijayaraman P, Zheng R, Cai M, Xu L, et al. Left bundle branch pacing for cardiac resynchronization therapy: nonrandomized on-treatment comparison with his bundle pacing and biventricular pacing. Can J Cardiol. (2021) 37:319–28. doi: 10.1016/j.cjca.2020.04.037

PubMed Abstract | CrossRef Full Text | Google Scholar

33. Upadhyay GA, Vijayaraman P, Nayak HM, Verma N, Dandamudi G, Sharma PS, et al. On-treatment comparison between corrective His bundle pacing and biventricular pacing for cardiac resynchronization: a secondary analysis of the His-SYNC pilot trial. Heart Rhythm. (2019) 16:1797–807. doi: 10.1016/j.hrthm.2019.05.009

PubMed Abstract | CrossRef Full Text | Google Scholar

34. Arnold AD, Shun-Shin MJ, Keene D, Howard JP, Sohaib SMA, Wright IJ, et al. His resynchronization versus biventricular pacing in patients with heart failure and left bundle branch block. J Am Coll Cardiol. (2018) 72:3112–22. doi: 10.1016/j.jacc.2018.09.073

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Vijayaraman P, Herweg B, Ellenbogen KA, Gajek J. His-optimized cardiac resynchronization therapy to maximize electrical resynchronization: a feasibility study. Circ Arrhythm Electrophysiol. (2019) 12:e006934. doi: 10.1161/CIRCEP.118.006934

PubMed Abstract | CrossRef Full Text | Google Scholar

36. Upadhyay GA, Vijayaraman P, Nayak HM, Verma N, Dandamudi G, Sharma PS, et al. His corrective pacing or biventricular pacing for cardiac resynchronization in heart failure. J Am Coll Cardiol. (2019) 74:157–9. doi: 10.1016/j.jacc.2019.04.026

PubMed Abstract | CrossRef Full Text | Google Scholar

37. Vinther M, Risum N, Svendsen JH, Møgelvang R, Philbert BT. A randomized trial of his pacing versus biventricular pacing in symptomatic HF patients with left bundle branch block (His-Alternative). JACC Clin Electrophysiol. (2021) 7:1422–32. doi: 10.1016/j.jacep.2021.04.003

PubMed Abstract | CrossRef Full Text | Google Scholar

38. Hua W, Fan X, Li X, Niu H, Gu M, Ning X, et al. Comparison of left bundle branch and His bundle pacing in bradycardia patients. JACC Clin Electrophysiol. (2020) 6:1291–9. doi: 10.1016/j.jacep.2020.05.008

PubMed Abstract | CrossRef Full Text | Google Scholar

39. Hou X, Qian Z, Wang Y, Qiu Y, Chen X, Jiang H, et al. Feasibility and cardiac synchrony of permanent left bundle branch pacing through the interventricular septum. Europace. (2019) 21:1694–702. doi: 10.1093/europace/euz188

PubMed Abstract | CrossRef Full Text | Google Scholar

40. Hu Y, Li H, Gu M, Hua W, Niu H, Zhang N, et al. Comparison between his-bundle pacing and left bundle branch pacing in patients with atrioventricular block. J Interv Card Electrophysiol. (2021) 62:63–73. doi: 10.1007/s10840-020-00869-w

PubMed Abstract | CrossRef Full Text | Google Scholar

41. Sheng X, Pan YW Yu C, Wang B, Zhang P, Li J, et al. Comparison of synchronization between left bundle branch and his bundle pacing in atrial fibrillation patients: an intra-patient-controlled study. Pacing Clin Electrophysiol. (2021) 44:1523–31. doi: 10.1111/pace.14331

PubMed Abstract | CrossRef Full Text | Google Scholar

42. Vijayaraman P, Patel N, Colburn S, Beer D, Naperkowski A, Subzposh FA. His-Purkinje conduction system pacing in atrioventricular block: new insights into site of conduction block. JACC Clin Electrophysiol. (2021) 8:73–85. doi: 10.1016/j.jacep.2021.07.007

PubMed Abstract | CrossRef Full Text | Google Scholar

43. Vijayaraman P, Cano Ó, Koruth JS, Subzposh FA, Nanda S, Pugliese J, et al. His-Purkinje conduction system pacing following transcatheter aortic valve replacement: feasibility and safety. JACC Clin Electrophysiol. (2020) 6:649–57. doi: 10.1016/j.jacep.2020.02.010

PubMed Abstract | CrossRef Full Text | Google Scholar

44. Qian Z, Qiu Y, Wang Y, Jiang Z, Wu H, Hou X, Zou J. Lead performance and clinical outcomes of patients with permanent His-Purkinje system pacing: a single-centre experience. Europace. (2020) 22(Suppl_2):ii45–ii53. doi: 10.1093/europace/euaa295

PubMed Abstract | CrossRef Full Text | Google Scholar

45. Ye Y, Zhang K, Yang Y, Jiang D, Pan Y, Sheng X, et al. Feasibility and safety of both His bundle pacing and left bundle branch area pacing in atrial fibrillation patients: intermediate term follow-up. J Interv Card Electrophysiol. (2021) 2021:1–10. doi: 10.1007/s10840-021-00964-6

PubMed Abstract | CrossRef Full Text | Google Scholar

46. Slotwiner DJ, Raitt MH, Del-Carpio MF, Mulpuru SK, Nasser N, Peterson PN. Impact of physiologic pacing versus right ventricular pacing among patients with left ventricular ejection fraction greater than 35%: a systematic review for the 2018 ACC/AHA/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delay. J Am Coll Cardiol. (2018) 140:e483–503. doi: 10.1161/CIR.0000000000000629

PubMed Abstract | CrossRef Full Text | Google Scholar

47. Chen K, Li Y, Dai Y, Sun Q, Luo B, Li C, et al. Comparison of electrocardiogram characteristics and pacing parameters between left bundle branch pacing and right ventricular pacing in patients receiving pacemaker therapy. Europace. (2019) 21:673–80. doi: 10.1093/europace/euy252

PubMed Abstract | CrossRef Full Text | Google Scholar

48. Massing GK, James TN. Anatomical configuration of the his bundle and bundle branches in the human heart. Circulation. (1976) 53:609–21. doi: 10.1161/01.CIR.53.4.609

PubMed Abstract | CrossRef Full Text | Google Scholar

49. Zhang S, Zhou X, Gold MR. Left bundle branch pacing. J Am Coll Cardiol. (2019) 7:3039–49. doi: 10.1016/j.jacc.2019.10.039

PubMed Abstract | CrossRef Full Text | Google Scholar

50. Huang W, Chen X, Su L, Wu S, Xia X, Vijayaraman P, et al. beginner's guide to permanent left bundle branch pacing. Heart Rhythm. (2019) 16:1791–6. doi: 10.1016/j.hrthm.2019.06.016

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: cardiac resynchronization therapy, His-Purkinje system pacing, biventricular pacing, meta-analysis, biventricular pacing, meta-analysis (as topic)

Citation: Gui Y, Ye L, Wu L, Mai H, Yan Q and Wang L (2022) Clinical Outcomes Associated With His-Purkinje System Pacing vs. Biventricular Pacing, in Cardiac Resynchronization Therapy: A Meta-Analysis. Front. Cardiovasc. Med. 9:707148. doi: 10.3389/fcvm.2022.707148

Received: 09 May 2021; Accepted: 13 January 2022;
Published: 11 February 2022.

Edited by:

Richard Hauer, University Medical Center Utrecht, Netherlands

Reviewed by:

Jiangang Zou, Nanjing Medical University, China
Yongquan Wu, Capital Medical University, China

Copyright © 2022 Gui, Ye, Wu, Mai, Yan and Wang. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Lihong Wang, wanglhnew@126.com

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.