Microfluidic integrated gas sensors for smart analyte detection: a comprehensive review

Arian Yeganegi&#x;Arian YeganegiKaveh Yazdani&#x;Kaveh YazdaniNishat TasnimNishat TasnimSomayeh FardindoostSomayeh FardindoostMina Hoorfar
Mina Hoorfar*
  • School of Engineering and Computer Science, University of Victoria, Victoria, BC, Canada

The utilization of gas sensors has the potential to enhance worker safety, mitigate environmental issues, and enable early diagnosis of chronic diseases. However, traditional sensors designed for such applications are often bulky, expensive, difficult to operate, and require large sample volumes. By employing microfluidic technology to miniaturize gas sensors, we can address these challenges and usher in a new era of gas sensors suitable for point-of-care and point-of-use applications. In this review paper, we systematically categorize microfluidic gas sensors according to their applications in safety, biomedical, and environmental contexts. Furthermore, we delve into the integration of various types of gas sensors, such as optical, chemical, and physical sensors, within microfluidic platforms, highlighting the resultant enhancements in performance within these domains.

1 Introduction

The air surrounding us and our exhaled breath contains many different gases which could be toxic and dangerous for human health and safety or contain markers of different diseases (Paknahad et al., 2012a; Li et al., 2014a; Yunusa et al., 2014). In recent years, the use of gas sensors for the detection and monitoring of these gases has been of great importance in environmental (Su et al., 2019a), safety monitoring (Lee et al., 2015a), and health-related (Paknahad et al., 2016a) fields.

The release of hazardous gases, such as volatile organic compounds (VOCs), ammonia, hydrogen peroxide, and petroleum gases, into the environment through different sources, including agriculture, transportation, industries, and commercial products, has deteriorated the ecosystem, changed the climate, and caused a lot of health complications, such as liver, brain, and respiratory problems (Anjum et al., 2018; Majhi et al., 2021; Narwade et al., 2021). According to the World Health Organization (WHO) report published in 2019, 91% of people worldwide reside in areas with air pollution exceeding the recommended threshold, leading to the death of approximately 4.2 million humans yearly (Buckley et al., 2020).

Gas sensors have been used widely in many safety-related applications, including public safety, household toxic gases, industries and warehouses, military and security, and food and beverage industries. Nowadays, detecting toxic and flammable gases is critical for public safety. Furthermore, as a safety measure, gas sensors are used in different industries to monitor gas leakages and are utilized in finding explosive gases (Yadav and Sinha, 2022).

The spread of numerous infectious diseases has posed a great threat to human health, and consequently, preventing the growth of these diseases has become crucial (Singh et al., 2020a). For example, gas sensors have been utilized for early diagnostics of Influenza and Ebola (Gouma et al., 2015). Monitoring and detecting more than 3,500 VOCs in the exhaled breath that can be biomarkers of different diseases is an effective use of gas sensors in healthcare applications (Dixit et al., 2021a; Kwiatkowski et al., 2018). For instance, the breath of people with diabetes, schizophrenia, and lung cancer patients frequently contains acetone, ethanol, pentane, and aldehyde (Rebordão et al., 2020a).

The conventional methods for gas sensing, like gas chromatography-mass spectroscopy, face some concerning challenges, including being bulky, expensive, time-consuming, and hard-to-operate, despite having high selectivity (Zhu et al., 2007; Barbosa et al., 2018; Rebordão et al., 2020b). This gives rise to the necessity of producing affordable, portable, selective, sensitive, and easy-to-use gas sensors, which are decent alternatives for conventional gas sensors at point-of-care and point-of-use applications. For example, by constantly monitoring human breath, these gas sensors can shed light on the cause of some respiratory diseases not directly related to environmental pollution, such as asthma, lung cancer, emphysema, and myocardial infection (Phillips et al., 1999; Kampa and Castanas, 2008). Also, they can be used in non-invasive disease diagnosis requiring low-volume biomarkers, such as dimethylsulphide and ketones, for diagnosing liver cancer and diabetes, respectively (Arasaradnam et al., 2014).

Miniaturization of gas sensors can lead to producing gas sensors with high accuracy, fast response and recovery time, low price, ease of use, and reduced analyte and reagent consumption. In this regard, microfluidic gas sensors can bring about various benefits due to their small size and the capability to integrate multiple functions into one platform, among the most important of which are being capable of in-situ detection, having low reagent consumption and high throughput and generating a quick response (Hong and Quake, 2003; Tani et al., 2004; Demello, 2006; Chen et al., 2019).

In this work, microfluidic-based gas sensors with wide applications in the environmental, safety, and health monitoring sectors have been investigated. The screening process involved selecting papers published between 1982 and the present, with a focus on the last 6 years for relevance. The papers were evaluated for their connection to gas sensor technology, particularly microfluidic-based sensors. Priority was given to reputable peer-reviewed journals and conferences in the gas sensing field. Keyword searches were conducted in databases like PubMed, Scopus, Web of Science, and Google Scholar, using terms like “gas sensors,” “microfluidic gas sensors,” and others related to monitoring applications. Studies specifically centered on microfluidic-based gas sensors were included, while those not directly relevant were excluded. Expert input was also incorporated to enhance the selection process. Papers published after 1980 were gathered and reviewed by three of the authors and categorized into the three mentioned categories. For data presentation, the authors did three rounds of data filtering. In the first round, all the papers published after 1980 and related to microfluidic gas sensing are considered. Any paper unrelated to microfluidic-based gas sensors (i.e., microfluidic-based liquid sensors), dissolved gas sensors, and all articles on microfluidic-based gas sensors published before 1980 are excluded. In the second round, each paper was reviewed by at least two of the writers and the paper was labelled as a review or technical research paper. Also, each paper was compared to our inclusion criteria, and the ones that did not meet the criteria were omitted. For the third and final round of filtration, the papers were reviewed deeply by at least two of the writers and categorized by the gas sensor application area into three different groups: environmental, personal safety, and health applications. At this step, some papers that did not meet the inclusion criteria were deleted again. Figure 1 show the number of papers gathered after each round of filtration and the number of papers based on application category, respectively.

FIGURE 1
www.frontiersin.org

FIGURE 1. Number of papers on microfluidic gas sensor at different steps of filtration (Top) Number of papers based on application category (Bottom).

Figure 2A represents the timeline view of the microfluidic gas sensor papers gathered for this review paper. As can be seen, the number of publications initially shows an increasing trend. However, after 2020, the trend changed, and the number of publications decreased. Figure 2B shows the distribution of publications based on countries and the corresponding authors. The countries with the most published papers are Canada, the United States, China, France, Germany, Iran, Japan, South Korea, Australia, India, Ireland, Italy, New Zealand, Portugal, Spain, Switzerland, and Thailand.

FIGURE 2
www.frontiersin.org

FIGURE 2. (A) Timeline view of the microfluidic gas sensor papers gathered for this review, (B) Geographical view of distribution of publications based on countries, and the correspondence authors.

Essential data and information were extracted from the selected papers and tabulated, including the gas sensor detector type, target analyte, sensor fabrication, microchannel fabrication, and response results. In the beginning, the working principle of different gas sensor types and the basic associated parameters are introduced. The next section discusses the systematic search strategy, eligibility criteria, and method of categorization of the papers. The three application categories of microfluidic gas sensors are introduced, and target analytes, detector types, and fabrication techniques are reviewed for each application. To conclude, this field’s research gaps and possible future are discussed.

2 Microfluidic based gas sensors: methodology, working principles, and performance metrics

In this section, the methodology, working principles, and performance metrics of different types of gas sensors that can be integrated with microfluidic channels are discussed.

2.1 Chemiresistive gas sensors

Generally, chemiresistive sensors work based on the conductivity change upon exposure to a target gas. Under the sensing conditions (temperature and humidity), the sensing layer is exposed to airflow at its steady state. At this stage, oxygen molecules get adsorbed at the surface of the sensing material in different types depending on the working temperature. The oxygen adsorption reaction traps electrons from the conduction band of the material which is generally a semiconductor, creating an electron depletion layer and hole accumulated layer at the surface of an n-type and p-type semiconductor, respectively. As the sensing layer is exposed to a target gas, the adsorbed oxygen species react with the target gas and change the density of the electrons in the conduction band. So, the sensing layer resistance would either increase or drop depending on the type of the it (i.e., n-type or p-type) and the type of the target gas (i.e., reducing or oxidizing). By exposing back to air, the sensing layer resistance will change, until it gets back to its initial value. Generally, the response value in chemiresistive gas sensors can be obtained by investigating either the conductivity changes or changes in resistance upon exposure to a target gas. The conductivity changes can be monitored by measuring the sensing layer conductivity (G, S), resistance (R, Ω), the current passing through (I, A), or the voltage of a series resistance (V, v), which all can be easily converted to one another. Assuming the resistance as the parameter being monitored, the response value is defined as the ratio of the sensing layer resistance at the steady state over the minimum resistance value the sensor reaches (RaRg) (upon exposure of an n-type sensing layer to a reducing layer or p-type sensing layer to an oxidizing gas), or vice versa (RgRa) (upon exposure of an n-type sensing layer to an oxidizing gas or p-type sensing layer to a reducing gas), where Ra is the resistance at the steady-state and Rg is the resistance upon exposure to a target gas. The response value can also be defined as the ratio of the total change in resistance over the resistance at the steady state stage (RRa×100).

The principles described above are fundamental to the operation of most chemiresistive gas sensors, enabling their use in a wide range of applications for smart analyte detection. Tin Oxide (SnO2), Zinc Oxide (ZnO), Tungsten Oxide (WO3), Titanium Dioxide (TiO2), and Copper Oxide (CuO) are some common examples of metal oxide based chemiresistive gas sensors widely used for detecting various gases, including methane (CH4), carbon monoxide (CO), nitrogen dioxide (NO2), ammonia (NH3), hydrogen (H2), hydrogen sulfide (H2S) and volatile organic compounds (VOCs). These sensors operate based on the changes in the electrical conductivity of the oxide sensing layer upon exposure to the target gas. For example, in the presence of reducing gases like methane, the conductivity of the n-type oxide sensor increases, resulting in a drop in resistance. Conversely, in the presence of oxidizing gases like nitrogen dioxide, the resistance increases. These examples highlight the versatility of metal oxide semiconductor (MOS)-based gas sensors and their ability to detect various target gases through changes in their electrical conductivity (Dey, 2017; Gaun, 2020; Singh Bhati et al., 2021).

In addition to MOS, there are several other types of chemiresitive gas sensors that are widely used for detecting various gases. Nanomaterials, such as nanowires, nanotubes, and nanoclusters made from various semiconducting materials, have shown promising gas sensing properties. These nanomaterial-based sensors offer high sensitivity and selectivity for different gases. Metal-organic frameworks (MOFs) are a class of porous materials with high surface area and tunable chemical properties. MOFs can be synthesized to have selective adsorption properties for specific gases, making them useful for gas sensing applications (Sohrabi et al., 2023).

TMDs (Transition Metal Dichalcogenides) and TMTs (Transition Metal Trichalcogenides) are two types of 2D semiconductor-based gas sensors that have attracted significant research attention due to their unique properties. Their large surface-to-volume ratio and tunable bandgap make them suitable for designing high-performance and sensitive gas sensors (Kumar et al., 2020; Rafiefard et al., 2020; Shooshtari et al., 2022; Wu et al., 2023; Yang et al., 2023).

TMDs are a class of materials composed of transition metals (such as Mo, W) and chalcogen elements (such as S, Se, Te) arranged in a layered structure. They have gained prominence due to their exceptional electronic and optical properties in the 2D form. Some common TMDs include MoS2 (Molybdenum Disulfide), WS2 (Tungsten Disulfide), MoSe2 (Molybdenum Diselenide), and WSe2 (Tungsten Diselenide). TMTs are another class of 2D semiconducting materials, but they differ from TMDs in that they contain three chalcogen elements (such as S, Se, Te) for each transition metal atom. Similar to TMDs, TMTs exhibit intriguing electronic and optical properties that make them promising candidates for various applications, including sensing.

It is worth noting that the field of 2D materials and semiconductor-based sensors is rapidly evolving, and new materials and sensor configurations may have emerged.

2.2 Optical

Optical gas sensors work based on the adsorption properties of chemical species in different regions of the electromagnetic spectra. The region of the mid-infrared (mid-IR) spectrum spanning from 2 to 20 μm holds special significance due to its presentation of distinct vibration/rotation absorption spectra featuring narrow, distinct bands for many of the gases mentioned earlier (Bogue, 2015). Generally, the adsorption-based techniques in optical gas sensors, work based on the Beer-Lamber adsorption law which can be described as Eq. 1.

I=I0×expαL(1)

Where I0 and I are the intensity of the light that has passed through the cell and the intensity of the incident light, respectively. Here, α is defined as the adsorption coefficient of the gas and L is defined as the optical path length (Hodgkinson and Tatam, 2012). The adsorption-based optical methods are categorized into two main groups: direct spectrometry and reagent mediated. In direct spectrometry, the changes in a light source intensity is investigated passing through a target gas cell, whereas, in reagent mediated techniques, the sensing properties are investigated via monitoring the changes in luminousness properties of a mediated material in the presence and absence of a target gas. The response value in optical gas sensors is defined based on the type of the optical sensor, i.e., direct spectrometry and reagent mediated optical gas sensor. In direct spectrometry optical sensors, the adsorption coefficient (α) is defined as the response value and it can be measured via investing the intensity of incident light and emitted light. In reagent mediated optical sensors, the sensing properties are investigated by monitoring the changes in the luminescence properties of the intermediate agent, such as the refractive index, wavelength and frequency of the diffracted wave (Youssef et al., 2012), and the emission intensity (Shirbeeny and Mahmoud, 2014). Therefore, the response value could have different definitions depending on the monitored parameter. If the emission intensity is the issued parameter, as the relative change of the emission intensity, the response value can be defined as (I0IgI0×100), where I0 and Ig are defined as the spectra intensity in the absence and presence of the target gas, respectively (Subashini et al., 2018). Similarly, if the frequency is being monitored, the response value is defined as (fsfrfr×100), where fs and fr are defined as the frequency of the optical wavelength in the absence and presence of the target gas, respectively (Kladsomboon et al., 2018).

2.3 Field effect transistor (FET)

In FET-based gas sensors, the sensing layer is used as the gate or channel of the transistor. These types of gas sensors are multi-parameter sensors meaning that upon exposure to a target gas, the change in the threshold voltage (Vth), transconductance (gm), field effect mobility (FET), or drain current (ID) can be monitored and investigated as the sensor response (Hong et al., 2021). The threshold voltage of the sensor can be defined as Eq. 2 (Jung et al., 2020).

Vth=ϕmsQoxCox+2ψB2qNDεSi2ψBCox(2)

Where ϕms is defined as the work function difference between the gate and the channel and Qox and Cox are defined as the oxide charge and gate-oxide capacitance, respectively. ψB, ND, and εSi are defined as surface potential at the threshold condition, doping concentration in the channel and the dielectric constant of Si, respectively. As the gas sensor is exposed to a target gas, the sensing layer reacts with the target gas and would either accept or donate electrons based on the type of the target gas (i.e., reducing or oxidizing, respectively). Then, the work function of the sensing layer changes and would shift the value of the threshold voltage which is monitored as the response (Jung et al., 2021). In FET-based gas sensors, the response can be investigated via monitoring the drain current change as the gate voltage and field effect changes upon exposure to a target gas. Therefore, the response value can be defined as (IaIgIg×100) where Ia and Ig are the current magnitudes upon exposure to air and the target gas, respectively (Kladsomboon et al., 2018).

2.4 Bubble-based gas sensing

Bubble-based gas sensing is a recent and innovative sensing mechanism to distinguish gas types both individually and in a mixture. The general concept of this method is to stream a target gas into a liquid, using a career gas, and monitor the change in the volume of the bubble upon streaming different target gases and gas mixture ratios. As the gas is streamed into the liquid, a portion of the gas is dissolved into the liquid and another portion diffuses through the liquid and forms bubbles. The diameter of these bubbles can be affected by three main parameters: gas diffusivity (k), gas solubility normalized by density (Csρ), and the ratio of the initial dissolved gas concentration over the saturation dissolved gas concentration CiCs (Bulbul et al., 2014). Therefore, based on the target gas characteristics, one of the three parameters becomes the main parameter in defining the bubble size as the gas is streamed into a liquid (Bulbul and Kim, 2015a). The response in these types of sensors is investigated via monitoring the bubble volume versus time upon injection of the target gas and any peak or sudden change in the volume of the bubble is investigated as the sensor response.

3 Microfluidic based gas sensors: applications, detection and fabrication

3.1 Environmental monitoring

The rapid growth of industry, agriculture, and transportation has culminated in releasing various harmful pollutants into the environment. Volatile Organic Compounds (VOCs) are among these hazardous pollutants. Benzene is a VOC with significant carcinogenetic characteristics, promoting the risk factor of getting diagnosed with leukemia and lymphomas (Ueno et al., 2003a). Formaldehyde, another type of carcinogenic VOC, is one of the causes of allergic diseases in people with asthma (Yu et al., 2020; on Cancer, 2004). Chlorine, which is widely used in papermaking, dyeing, printing, and producing hydrochloric acid, and phosgene, is another harmful environmental pollutant that can harm the skin and respiratory tract, even at sub-ppm concentration (Gao et al., 2008). Ammonia is one of the essential chemicals in agriculture, as it is the foundation for all nitrogen (N) fertilizers (Riva et al., 2016), and its exposure to humans can adversely affect the eyes, skin, respiratory system, and gastrointestinal system (Welch, 2006).

Because of the detrimental effects of the pollutants mentioned above, stringent regulations are applied to control their concentration. For example, the upper limit for the concentration of benzene in the United States (U. S. E. P. A. USEPA, 1999), Japan (Ministry of the Environment, 2009), and the European Union (Directive, 2000) is equal to 0.33, 1.0, and 1.6 ppb, respectively. The maximum allowable concentration of chlorine in the atmosphere that does not pose a danger is 0.3 ppm in China (Gao et al., 2008). According to the WHO, humans should not be exposed to more than 0.08 ppm concentration of formaldehyde over 30 min (Guo X.-L. et al., 2018). Pollutants can be produced either by indoor sources, such as paints, solvents, cleaning materials, and smoke, or by outdoor sources, such as agriculture, automobile exhaust, and industry. We also spend about 85 percent of our time in closed environments such as houses, schools, supermarkets, and offices (Guillam et al., 2010; Mugherli et al., 2020). With these in mind, it is of paramount importance to design a portable gas sensor with a low limit of detection. Gas chromatography and capillary electrophoresis are among the highly sensitive gas sensors that can detect harmful pollutants with a detection limit below their threshold. That being said, they are expensive, difficult to use, sedentary, and heavy, making them unsatiable options for indoor and on-site measurements. Miniaturization of gas sensors can lead to the production of gas sensors with high accuracy, fast response and recovery time, low price, ease of use, and reduced analyte and reagent consumption. Gas sensors miniaturization can be achieved by designing microfluidic gas sensors. In what follows, we delve into various types of microfluidic gas sensors utilized to detect a wide array of analytes for monitoring gases posing a threat to the environment.

A wide array of gas sensors has been developed to detect different pollutants. In this regard, some gas sensors, like MOS-based ones, can be used in microfluidic systems in various ways. For example, Becker et al. were the first researchers that suggested the concept of using MOS in a microreactor to detect environmental pollutants, including ozone (O3), nitrite oxides (NO and NO2), CO, and CH4, (Becker et al., 2001a). They showed that using microreactor chambers with a volume of 45 µL can enhance the selectivity and response time of the gas sensor. This type of gas sensor includes two microreactor systems. The first one is utilized to detect reducing gases, including CO and CH4, and the second is used to detect oxidizing gases, including O3, NO, and NO2. Each microreactor is made of a chamber containing a SnO2 gas sensor surrounded by opening and closing valves. Such a system can operate in constant-flow and no-flow modes. A micropump pumps the analyte into the chamber in the constant-flow mode, and the no-flow mode initiates by closing both the inlet and outlet valves. In the no-flow mode, the gas trapped in the chamber reacts with tin oxide surfaces and produces a unique signal whereby it can be specified. However, using an external pumping source in microfluidic systems has some drawbacks, including space requirement, electrical noise, and sensor response deterioration. This problem can be addressed by integrating gas pumping into the microchannel. To address this problem, Martini et al. suggested that gas flow through the microchannel can be instigated by thermal creep along the microchannel by heating the sensing element (Martini et al., 2012a). Even though designing this microfluidic gas sensor was an important step toward miniaturizing MOS-based microfluidic gas sensors, the proposed detector has drifting issues. Tackling this problem leads to the emergence of a new type of MOS-based microfluidic gas detector. These types of gas detectors classify analytes based on their diffusivity through the microchannel and their interactions with the walls through desorption and adsorption. Given that the analyte is recognized by its physical properties rather than its chemical properties, these gas sensors have great potential to avoid generating drifts.

To the best of the authors’ knowledge, Hossein-Babaei and Ghafarinia were the first researchers that utilized this concept for gas identification (Hossein-Babaei and Ghafarinia, 2010a). The designed device consists of a 50 mm × 50 μm microchannel made of borosilicate. It uses a tin oxide-based sensor to discriminate between 24 gaseous analytes with a detection limit of 500 ppm for some of the analytes, including methanol. The sensor can also estimate the compositions of binary and ternary mixtures of analytes at various concentrations. Later, Mohaghegh Montazeri et al. (2019) used COMSOL Multiphysics to develop a numerical method capable of accurately simulating diffusion, adsorption/desorption, chemical reaction, and heat and mass transfer phenomena in the MOS-based microfluidic gas sensor. This numerical method is then used in other publications (Ghazi et al., 2021a; Ghazi et al., 2022a) to improve the LOD by modifying the channel’s geometry. While diffusion-based gas detectors eliminate most of the drifts caused by chemical reactions, their responses still depend on environmental factors, including ambient temperature and humidity. In this regard, Paknahad et al. (2014) considered the sensor a multi-input-single-output system, where the analyte (methanol) concentration in air and ambient temperature and humidity are the inputs of the system, and the output is the resistance of the sensing element. They used the analysis of variances method to carry out a sensitivity analysis to find out which inputs or their possible interactions have the most pronounced effect on the output of the device. According to the results, temperature, humidity, analyte concentration, and the interaction of the last two parameters have the most impact on the device response. In addition, a regression model is used to predict the response of the device at temperature, humidity, and analyte concentration for which experimental data are not available. In another study, Paknahad et al. (2018) studied the effect of different levels of humidity, ranging from 15% to 80%, on the performance of a diffusion-based microfluidic gas detector in detecting four different analytes, including 2-pentanol, 2-pentanone, methanol, and ethanol. The results showed that the gas detector is unable to distinguish between analytes when a small change in humidity level occurs. To tackle this problem, they developed a humidity removal membrane made of different inorganic compounds, leading to a 36% improvement in the selectivity of analytes.

In addition to the miniaturization of MOS-based gas sensors, several attempts have also been made to miniaturize optical gas sensors. Ueno et al. attempted to miniaturize GC-MS by using a nanostructured material, mesoporous silicate SBA-15, as a gas chromatographer to detect VOCs, including benzene, toluene, and xylenes (BTX) (Ueno et al., 2003a). This microfluidic device consists of two Pyrex plates, namely, separation and detection plates, with a size of 3 cm × 1 cm. Mesoporous silicate is placed in a microchannel at the separation plate and functions as an adsorbent. The adsorbed components are then heated by a thin-film heater. The samples will be desorbed at different rates based on their desorption temperatures and will then be sent to the spectrometer.

Chemiluminescence (CL) is a simple, selective, and cheap detection method that does not require optical systems and light sources, making it a more straightforward alternative than GC-MS (Su et al., 2004). Gao et al. (2008) developed a microfluidic-based CL to detect chlorine gas with a detection limit of 0.2 ppm. They utilized luminol solution as a CL reagent to instigate chemical reactions required to release electromagnetic radiation. When chlorine reacts with an alkali solution, like luminol, it converts into hypochlorite ion (ClO) and luminal converts to an excited state of phthalate. Having returned to the ground state, luminol releases light with a wavelength of 425 nm, which will be detected by a photomultiplier tube (Marquette and Blum, 2006). The luminol also functions as an absorption reagent, eliminating the possibility of forming bubbles at liquid-gas interfaces, which can adversely affect the accuracy of the device.

Fluorescence (FL) is like CL, except a chemical reaction does not cause electromagnetic radiation. In this method, the analyte or another molecule formed by the analyte is bombarded by photons, raising electrons to the excited level. The excited electrons then undergo energy loss and generate electromagnetic radiation by which they can be identified. Becker et al. developed a microfluidic FL gas detector (20 cm × 25 cm × 15 cm) to detect formaldehyde with a detection limit of 0.08 μg m−3 (Becker et al., 2020). In this device, a porous interface is used to trap formaldehyde in the acetylacetone solution, where the Hantzsch reaction transforms the trapped formaldehyde into a fluorescent molecule 3,5-Diacetyl-1,4-dihydrolutidine (DDL). The formed DDL is then detected with the use of fluorescence.

The first step toward miniaturization of optical absorption spectroscopy (OAS) gas sensors was taken by Mortensen et al. (2008). They showed that the use of a photonic crystal (PC) waveguide could improve the light absorption of the analyte by instigating slow-light optical propagation in the absorption chamber. Lai et al. (2011) showed that the combined effect of slow-light propagation with the electric field intensity enhancement created by making a slot in the PC waveguide could decrease the absorption length by a factor of 1,000, making it suitable in gas sensing applications. Alternatively, Cubillas et al. (2009) suggested the use of a hollow-core photonic crystal fiber (HPCF) to decrease the absorption length, where the electric field confined in a hollow-core interacts with the analyte following through it. Ebnali-Heidari et al. (2014) improved the HPCF concept by introducing tunability to the device by utilizing optofluidic infiltration techniques. Also, Su et al. (2019b) developed an OAS microfluidic device with an on-chip detector. This device, which utilizes a waveguide integrated PbTe detector, has better response time and lower noise and can detect methane with the detection limit of 330 ppmv.

While photoionization detectors (PIDs) are non-destructive and have high sensitivity and selectivity, they are not suitable in GC and microfluidic GC because of their high response time stemming from their large ionization chamber and dead volume. Zhu et al. (2015) utilized an archimedean spiral channel GC in concert with a rapid, flow-through, and sensitive microfluidic PID to detect various VOCs, including benzene, toluene, ethylbenzene, m-Xylene, and hexane, with the detection limit of 0.2, 0.24, 0.34, 0.34, and 0.23 ppt, respectively. The flow-through design of the PID allows it to have a low dead volume ( 2 nL), and the volume of the ionization chamber is 1.3 μ L, which is over 100 smaller than conventional PIDs.

In addition to conventional MOS-based and optical gas sensors, microfluidic systems allow us to develop more innovative methods for the detection of analytes. For example, Bulbul and Kim developed a microfluidic bubble-based gas sensor to detect CO2, He, H2, CH4, pentane (C5), and various mixtures of CO2—N2, (Bulbul and Kim, 2015b). In this method, as shown in Figure 3, helium, as an inert gas, carries a mixture through a conventional capillary column chromatographer, where the mixture is separated into its constituents. The separated gas is then transformed into a liquid channel, where bubbles will be formed because of gas-liquid interactions. Each type of gas produces bubbles with unique volumes and linear expansion coefficients, which help us to specify the type of gas.

FIGURE 3
www.frontiersin.org

FIGURE 3. The mechanism of the bubble-based gas sensor: the gas mixture is separated into its constituents by passing through a separation column. Then, having passed through a flow-focusing microchannel, different analytes will be categorized based on their bubble diameter (Bulbul and Kim, 2015b). Reprinted with permission from RSC.

3.1.1 Fabrication methods

Several factors should be considered when it comes to the fabrication of gas sensors. For example, in MOS-based microfluidic gas sensors working based on the diffusion and adsorption of analytes, increasing the surface to volume ratio promotes the adsorption rate of the analyte to the microchannel’s walls, leading to the improvement of the sensor’s selectivity. Researchers have utilized various techniques in the fabrication process of these sensors to increase the surface-to-volume ratio. In this regard, Ghazi et al. (2021a) enhanced the selectivity of the sensor in detecting 100 ppm of seven various analytes (methanol, ethanol, propanol, pentanol, hexane, hexanal, and toluene), increasing the surface to volume ratio by decreasing the channel width and introducing nanofeatures and functional groups to the microchannel. The first part of the study, which investigates the effect of channel width on sensor selectivity, is carried out through numerical simulations, leading to an average enhancement of 93.44% and 60.1% in the selectivity of polar and non-polar VOCs, respectively. Then, the surface of the channel is modified by graphene dots, leading to an average improvement of 98.72% and 86.6% in the selective detection of polar and non-polar analytes, respectively. Finally, combining the methods mentioned above culminates in an average improvement of 101.45% and 98.82% in the selectivity for polar and non-polar analytes.

The gas sensors’ fabrication method also plays a critical role in their portability and safety. In this regard, Rezende et al. (2019) designed a microfluidic PID using micro-milling and electrical discharge machining fabrication techniques to detect toluene with the highest detection limit of 0.6 ppm. The unique fabrication of the device allows quick mount and dismount of its components. The shell of the assembly, which encapsulates all components together to minimize leakage, is made of PVC. Electrodes are fabricated by the electrical discharge machining approach and are made of copper because of its availability and high thermal conductivity. Should the electrodes be exposed to radiation higher than the operating condition of copper [4.48–4.94 eV (Haynes, 2014)], the electrons will be ejected from their surface, causing signal noise. To address this issue, the authors used two different coatings, namely, PMMA and diamond-like carbon, to filter the destructive radiations.

The new generation of smartphones provides a unique platform for implementing microfluidic technology for health monitoring (Yang et al., 2016). For example, since their digital color cameras can evaluate the color of an object, they can function as the sensor in a colorimetric gas detector. Guo X.-L. et al., 2018a developed a smartphone-based microfluidic colorimetric detector to detect formaldehyde with a detection limit of 0.01 ppm. This study chose 4-aminohydrazine-5-mercapto-1,2,4-triazole (AHMT) as the sensing reagent due to its high sensitivity, selectivity, and short response time. To prevent the fluid from coming out of the microfluidic device and allow gas samples to get in, a hydrophobic porous polytetrafluoroethylene (PTFE) membrane is utilized on the top of the reaction chamber.

Innovative fabrication methods can also be used to enhance the performance of existing microfluidic devices. Tirandazi and Hidrovo fabricated a novel colorimetric device to detect airborne gaseous analytes (Tirandazi and Hidrovo, 2018). In this method, as shown in Figure 4, the liquid mixture containing the sensing reagent is injected into a continuous gas flow carrying the analyte, leading to the formation of droplets due to the interfacial tension and shear forces caused by the gaseous phase. The formed droplets are then gathered in an immiscible liquid medium, which functions as the secondary carrier. After that, the formed droplets are carried by the secondary carrier through a microchannel network, where further analysis is carried out on them. They used this method to detect vaporized ammonia (NH3). To that end, the liquid phase containing the Nessler reagent is injected into a mixture of dry air and ammonia. As a result of the reaction between Nessler and ammonia, the orange color spreads in the formed droplets. The colorimetric study with the detection limit of 500 ppm is then conducted using a high-speed CMOS camera (Photron SA5) coupled with a Nikon Ti-U inverted microscope as the sensor and a metallic halide white lamp as the light source. Mugherli et al. (2020) fabricated a novel FL method to detect formaldehyde. Two different molds are used to fabricate the microdevice into PDMS. The top part of the device, which is a medium through which the analyte flows, is formed using solid-film resins, and the bottom portion is made on a micro-machined brass mold. They used the sol-gel process to create the porous medium made of silica-zirconia materials. They used the anchored droplet method to generate well-calibrated micro-spheres liquid droplets with the size of 30 nL (sol phase) (Abbyad et al., 2011). Then, the porous medium is generated through the gelation of the generated droplets (gel phase). They included 4-amino-3-penten-2-one probe molecules in the sol phase, which turn into fluorescent 3,5-diacetyl-2,6-lutidine after reacting with formaldehyde.

FIGURE 4
www.frontiersin.org

FIGURE 4. The mechanism of the colorimetric gas sensor suggested by Tirandazi and Hidrovo (Tirandazi and Hidrovo, 2018): I) The liquid phase carrying reagent enters a flow focusing microchannel, where they will be mixed with the gas analytes, II) the formed droplets containing both analytes and reagents are gathering in a liquid medium, III) The formed droplets are then carried through a series of microchannels by the liquid carrier, where further analysis is conducted on them. Reprinted with permission from Elsevier.

3.1.2 Analytes

Miniaturization of conventional gas detectors can extend their selectivity. For example, conventional PIDs use sealed lamps containing permanent and noble gases, such as xenon, krypton, and argon, to generate plasma that emits photons with the energy of 9.6–11.7 eV. These detectors cannot specify analytes whose ionization energy is higher than 11.7 eV, such as formaldehyde, which is one of the most important sources of environmental pollution. To tackle this problem, the researchers developed helium discharge PIDs (HDPIDs), which use helium to emit photons with the energy of 13.5–17.5 eV (Freeman and Wentworth, 1971; Gras et al., 2006; Shinada et al., 2012). However, HDPIDs’ bulky design and high helium consumption limit their application to laboratory use and make them unviable in portable GC applications. Maxwell et al. designed a microfluidic HDPID with low power and helium consumption with an in-house plasma excitation system and readout circuits (Li et al., 2021). The device was utilized to analyze permanent gases, light hydrocarbons, and formaldehyde. The limit of detection is less than 10 pg for VOCs and less than 20 pg for permanent gases, where argon with 15.76 eV ionization potential has the highest limit of detection of 19.8 pg.

The hydrophobicity of analytes plays an integral role in the selectivity of the MOS-based microfluidic detectors. In this regard, Paknahad et al. investigated the effect of channel coating hydrophobicity on the selectivity of the detector to differentiate seven different analytes with various polarities (methanol, ethanol, 1-propanol, 2-pentanol, acetone, pentane, and hexane) (Paknahad et al., 2019a). The results show that the non-polar channel coatings have better selectivity when it comes to polar analytes. This is due to the high diffusivity of polar gases, which makes diffusion the dominant factor in the diffusion-physisorption equation. With this in mind, the channel coating, which mainly affects the physisorption of the channel, has a less pronounced effect on polar analytes.

Using machine learning to differentiate between various analytes helps operators work with detectors more conveniently and faster, especially for the analytes whose responses are similar. Barriault et al. (2021) used various machine learning methods, including k-nearest-neighbors, random forests, multilayer perceptron, support vector machines, and convolutional neural networks, to discriminate between pure methane and natural gas containing 1%–3% ethane and specify the concentrations of methane and ethane in arbitrary binary mixtures of them using a MOS sensor (FIGARO, TGS 2602). According to the results, the device can distinguish between methane and natural gas with 98.75% accuracy and can specify the concentrations of methane in natural gas mixtures containing 1% and 3% ethane with an accuracy of 86.7% and 93.3%, respectively.

Developing a gas detector capable of detecting analytes with sub-ppm concentration is another challenge that can be addressed by using microfluidic systems. Surface-Enhanced Raman Spectroscopy (SERS) is a gas sensing method that detects analytes with femtomolar or lower concentrations (Grubisha et al., 2003). Miniaturization of these sensors helps us continuously monitor gaseous molecules released from explosions, toxic airborne compounds, and environmental contaminations (Dubnikova et al., 2005). Piorek et al. (2007) attempted to develop a microfluidic SERS gas sensor, as illustrated in Figure 5). They made a 1.5 µm × 15 µm microfluidic channel through which a free-surface flow is flowing. The small size of the microchannel provides a situation wherein the flow is confined merely by surface tension. Then, they distributed Au nanoparticles throughout the channel. The free-surface flow absorbed the analyte, namely, 4-amino benzenethiol (4-ABT). Then, the absorbed 4-ABTs diffuse through the microchannel until they adsorb onto the surface of Au nanoparticles, replacing the surface ions. The adsorbed analyte promotes the aggregation of the Au nanoparticles, forming SERS hot spots. The entrained analytes in SERS hot spots generate intense SERS spectra whereby they can be detected.

FIGURE 5
www.frontiersin.org

FIGURE 5. The mechanism of the microfluidic SERS gas sensor, (A) The carrier liquid flows from the reservoir into the open microchannel, (B) Au nanoparticles adsorb analytes, which leads to the formation of Au aggregates function as SERS hotspots (Piorek et al., 2007). Reprinted with permission from PNAS.

3.2 Personal safety monitoring

One of the leading causes of illness and mortality around the world is exposure to pollutants, toxic, and explosive compounds (Atkinson, 2000; Li et al., 2014b; Raj et al., 2015). As a result, in the last few decades many regulations have been established in order to ensure the safety of personnel, and people in different working and living areas (Bulbul et al., 2014; Bulbul and Kim, 2015a). To make sure that the established regulations and requirements are satisfied fully different sensing and monitoring devices are needed in different environments. Implementation of gas sensing and monitoring devices in a variety of living and working environments is essential to guarantee the safety of people and personnel (Youssef et al., 2012; Shirbeeny and Mahmoud, 2014). To do so, different methods and devices have been used in the past few decades such as gas chromatography and mass spectrometry (Subashini et al., 2018; Kladsomboon et al., 2018), optical-based methods (Vashist and Luong, 2018; Yu et al., 2020), acoustic-based methods (on Cancer, 2004; Gao et al., 2008), and calorimetric methods (Riva et al., 2016; Welch, 2006). Despite the advantages which these devices provide they suffer from several issues and limitations including being bulky and expensive, fabrication difficulty, risk of catalyst poisoning, risk of explosion, poor sensitivity and selectivity, need of having an expert operator, and long-term instability (Mahajan and Jagtap, 2020; Ghazi et al., 2021b). On the other hand, microfluidic gas sensors have provided compact, light, inexpensive, and user-friendly solutions for safety monitoring and as a result, they have been used excessively in this area (Ministry of the Environment, 2009; Directive, 2000). As an example, in a study, Lee et al. (2015b) fabricated a microfluidic-based gas sensor using which they were able to determine the quality of different foods and whether they are spoiled. The fabricated device can then be used to prevent illnesses caused by food poisoning. In this work, the authors developed a microfluidic-based bioelectronic nose that is able to detect gaseous trimethylamine (TMA) in a real-time and online approach (Lee et al., 2015b). Functionalized single-walled carbon nanotube-field effect transistors (SWNT-FETs) were used as the detectors of TMA which showed not only an excellent limit of detection (LOD) of 10 ppt but also a great selectivity toward TMA and other odors. The successful fabrication of SWNT-FETs and also the gas sensing properties are shown in Figures 6A–H. Microfluidic gas sensors also have potential use in the wine industry, where they could enhance the quality assessment of the wines and help rapidly identify different types of them (Paknahad et al., 2017a).

FIGURE 6
www.frontiersin.org

FIGURE 6. (A–H) The results of SWNT-FETs characterizations tests and gas sensing properties (Lee et al., 2015b). Reprinted with permission from Elsevier.

Similar to the mentioned example, there are more publications available in the literature which are proofs of successful utilization of microfluidic gas sensors for personal safety monitoring. Some of the remarkable works in the field are categorized based on the analyte type, detector type, and fabrication method which are discussed in the following sections.

3.2.1 Target analytes

Different target analytes are of interest when it come to the personal safety monitoring, analytes such as sulfur-based compounds, ammonia, ozone, BTX, some ketones, and some hydrocarbons (Aliyu et al., 2015; Ghaderahmadi et al., 2021a; Song et al., 2021). Microfluidic gas sensors have shown to be promising methods for personal safety monitoring, they have been used widely for detecting and monitoring NOx (Meckes et al., 1999), VOCs such as alcohols and ketones (Janfaza et al., 2019a), hydrocarbons such as alkanes (Ghazi et al., 2021c), ammonia (Martini et al., 2012b), carbon monoxide (Meckes et al., 1999), and ozone (Becker et al., 2001b).

In a study Meckes et al. (1999) proposed a microfluidic system for gas detection. The proposed system is consisted of different channels (controlled by microvalves) and a sensing chamber (with a thin film gas sensor). The proposed setup can help improve the selectivity if the sensor and reduce the baseline drift. The authors used the setup for monitoring 100 ppm of NO and CO gases, each testing cycle is consisted of purging, calibration, and measurement steps. It has been shown that the device’s response/recovery time toward 100 ppm of NO and CO are 110/865 s and 172/844 s respectively.

Ammonia is among the most toxic gases and exposure to it can affect the health severely, as a result monitoring it is vital to minimize the risks. In a work (Martini et al., 2010) fabricated a gas detection microfluidic system which is capable of detecting ammonia. In this study the materials and the dimensions of the microfluidic system has been chosen based on the simulation results. Silicon and Pyrex were studied in the computational studies and based on the results Pyrex would be a better candidate than silicon. Figure 7A, shows the device with its dimensions. A MOS detector (WO3) is used and combined with the microchannel. The device was exposed to different concentrations of ammonia ranging from 10 to 100 ppm. Figures 7B, C show the calibration curve and short term stability of the proposed setup.

FIGURE 7
www.frontiersin.org

FIGURE 7. (A) Image of the microfluidic gas detection system, (B) The calibration curves, (C) The short term stability study of the proposed setup (Martini et al., 2010). Reprinted with permission from Elsevier.

3.2.2 Detector types

Generally, detectors used in microfluidic gas sensors for personal safety monitoring can be categorized into three main groups including chemiresistors, optical sensors, and colorimeters (Ghazi et al., 2022b; Ueno et al., 2005a; Lee et al., 2015c). Each of these detectors provides specific advantages and disadvantages based upon which they are used for different applications with different requirements, and limitations. Among different available chemiresistors, MOS sensors have been used in microfluidic gas sensors the most. This group of sensors provides fast, and sensitive response signals with relatively low costs and ease of operation (Ghaderahmadi et al., 2021b). However, they suffer from poor selectivity, and in some conditions poor stability. Paknahad et al. (2019b) used a tin oxide semiconductor in a microfluidic gas sensor to detect 1,000 ppm of different VOCs including hexane which is known to be the cause of negative pulmonary changes. In this study the authors mounted a commercially available tin oxide detector (Figaro TGS 2602) at the end of a microfluidic channel (to improve the selectivity of the MOS sensor) and achieved and improved performance by optimizing the surface chemistry of the microchannel in terms of the polarity. It has been shown that using a non-polar coating (i.e., Cytonix on top of Parylene C) for the microchannel improves the selectivity of the sensor toward non-polar compounds such as hexane based on the “like dissolves like principle”. Normalized response signals of this sensor to different analytes and the schematic of the sensor, and sensing setup are shown in Figure 8.

FIGURE 8
www.frontiersin.org

FIGURE 8. (A) Normalized response signals of the microfluidic gas sensor with tin oxide detector to seven different analytes with eight repetitions, (B) Schematic of the microfluidic gas sensor, and (C) The schematic of the sensing setup (Paknahad et al., 2019b). Reprinted with permission from Springer Nature.

Another group of detectors which have been widely used in microfluidic gas sensors are optical detectors. These group of detectors provide high sensitivity, long term stability, and low LOD. However, their application is limited due to a few downsides such as high cost and complexity (Liu et al., 2012). In a study Ueno et al. worked on detection of benzene, toluene, and xylene with high selectivity (Ueno et al., 2005a). The authors fabricated a concentration channel with length of 5 mm loaded with 0.5 mg of adsorbent. A microchannel with inlets and outlets is integrated into the detection unit which is aligned between a UV light source (30 W deuterium (D2) lamp, Soma Optics) and a UV spectrometer (modified Fastevert S-2400, Soma Optics). Both ends of the channel are also covered with optical fibers (Figure 9A). It is stated that by introducing mesoporous silicate (SBA16) to the microfluidic setup, a 100 ppb limit of detection of benzene with high selectivity can be achieved due to it’s uniform cubic structure (Figure 9B). In another study, Chatterjee et al. have developed an optical hydrogen gas sensor utilizing aluminum-doped zinc oxide (AZO) nanotubes inside a microchannel. After exposing their sensor to hydrogen gas at room temperature and pressure, a considerable shift in the wavelength and reduction in the reflectance intensity is reported (Chatterjee et al., 2020).

FIGURE 9
www.frontiersin.org

FIGURE 9. (A) Schematic of the gas sensing device, (B) TEM images of SBA-15, SBA-16, SBA-15-acid, and CPG (Chatterjee et al., 2020). Reprinted with permission from RSC.

Microfluidic gas sensors that are based on nanomaterials have high sensitivity, selectivity, reliability, small size, low power consumption, and prolonged stability. Hence, these nano gas-sensitive materials have drawn significant research interest. For instance, Liu et al. have used first principles to study the potential of Mo2C in the detection of SF6 decomposition products and they demonstrate that MO2C can play a critical role in FET microfluidic selective gas sensing (Liu et al., 2022).

3.2.3 Fabrication methods

One of the main challenges of gas sensors is detecting analytes in the order of ppb. Preconcentrators can increase the concentration of a low-volume sample by decreasing its volume. Preconentrators are made of the adsorption and desorption processes. In the former, adsorbents adsorb the analytes; in the latter, heaters heat the adsorbents to trigger the analytes to be released (Lu and Zellers, 2002). However, the conventional preconcentrators are big in size, and their desorption stage requires a substantial amount of heat and consumes a lot of power. In this regard, Dow et al. fabricated a preconcentrator microfluidic system to detect ethylene, which is the sole indicator of fruit ripening (Dow et al., 2011). The microfluidic device comprises a series of silicon trenches whose walls function as heaters, and their surfaces are loaded by carboxen 1,000 adsorbent. Silicon trenches are etched using DRIE process. Then, anodic bonding is used to compress silicon microstructures between two Pyrex glass. The device can increase the concentration of 100 ppb ethylene by 100 time, and detect it using a PID.

Coating the surface of microchannels is another method whereby researchers can increase the selectivity of the sensors. Molecularly imprinted polymer (MIP) is a synthetic polymer that can differentiate between different analytes due to the presence of binding sites compatible with the analytes’ size and shape. Janfaza et al. coated MIP nanoparticles with acetone recognition sites on microchannels to improve the selectivity of MOS-based microfluidic gas sensors toward different concentrations of methanol, ethanol, acetone, acetonitrile, butanone, and toluene ranging from 200 to 4,000 ppm (Janfaza et al., 2019a). A 3D printer is used to fabricate the microchannel with 500 µm height. Then, a chemical vapor deposition coating machine is used to coat the surface of the channels with Parylene C. A specified amount of MIP nanoparticles is then suspended in acetonitrile and dropcasted on the surface of the microchannel. The drying process is carried out in a clean air chamber over a day. The characterization test results are provided in Figures 10A, B and the sensor was exposed to different concentrations of different VOCs (Figure 10C)). The response values of 0.17 (vg-va), and 0.315 (vg-va) are reported when the sensor is exposed to 800 ppm of acetone and methanol respectively along with the response times of 85 and 45 s.

FIGURE 10
www.frontiersin.org

FIGURE 10. (A) FTIR spectra, (B) SEM photographs of synthesised MIP nanoparticles, (C) Results of the modified microfluidic gas sensor when exposed to 800 ppm of different VOCs (Janfaza et al., 2019a). Reprinted with permission from Springer Nature.

3.3 Biological related monitoring

Sensors have been utilized in many different areas, including medical and health applications, environmental monitoring, and a wide range of other industrial uses. In recent years developing devices that can sense biological parameters (biosensors) have been essential for the health industry to detect diseases in humans and cure illnesses. Biosensors have a vast area of applications (Salim and Lim, 2018; Serra, 2011). Disease monitoring, drug discovery, and the detection of contaminants, illness-causing micro-organisms, and markers that are signs of disease in bodily fluids are among the many biosensors’ applications. Among the health-related applications of biosensors, we can name cancer cell detection, cholesterol detection, glucose sensor, bacterial biosensor, pH measurement, and DNA biosensor (Antony et al., 2014a; Bhalla et al., 2016).

Biosensors are composed of three parts, a sensing material, a transducer, and an electronic system. A biosensor is categorized according to different sensing materials and transducer into various types (Singh et al., 2020b).

The goal of the healthcare industry has been the diagnosis of the disease, monitoring its propagation, and following the treatment results by implementing a non-invasive approach. Achieving this goal requires knowledge of biomarkers of different illnesses, a non-invasive technique to detect and monitor the biomarkers, and technology to distinguish the biomarkers. Diabetes, cardiovascular disease, and cancer are three of the many diseases that affect humanity significantly, and the need for an early diagnosis and a monitored treatment is crucial (Bhalla et al., 2016). Consequently, there is a significant need for a sensor to detect specific biomarkers. Gas detection and quantification, using different types of gas sensors, have been successful solutions for assessing health status (Antony et al., 2014b).

Microfluidics is becoming a widespread tool in various fields, including the gas sensor industry. Since the development of microfluidic gas sensors, they have played a crucial role in many biological and health-related applications. These devices are widely used in biomedical applications due to their excellent selectivity and sensitivity, as well as their quick response time.

3.3.1 Target analytes

Different types of gas sensors have been used for health monitoring applications. Their goal is to detect certain analytes that can be useful in the detection of health problems. Methanol, ethanol, acetone, isoprene, isopropanol, propane, and undecane are of the many biomarkers that can be helpful in diagnosing diabetes, lung cancer, heart failure, and cystic fibrosis (Dixit et al., 2021b). One of the main analytes that have been studied over the years is oxygen. The ability of cells to take in oxygen is a potent indicator of sensitivity to external and internal stimuli, as well as their metabolic health and the development state of higher organisms and consequently, oxygen monitoring is of great importance (Nock et al., 2008a). Ammonia, alcohols (methanol, ethanol, and acetone), nitrogen oxide, benzene, and hydrogen have also been investigated as target analytes in the literature (Zhang et al., 2022).

Cooney and Towe (2004) have shown that in the case of using suitable sensor residence times, blood gas can be analyzed using a microdialysis-based optical sensor inside of the blood. One of the main analytes that have been studied over the years is oxygen. Bunge et al. (2019a) have studied the development of a microfluidic system to track the intake of oxygen by mammalian cells, which is a direct measure of metabolism. Their emphasis was on oxygen sensing, as well as its applicability in biolabs for large-scale cell assessments. Grist et al. (2015a) dived deep into improving sensor stability which is a must for long-term oxygen monitoring experiments. They developed a microfluidic oxygen control device with integrated ratiometric oxygen sensors to monitor chronic and cyclic Hypoxia. In another study, the patterning process was utilized to detect locally changing oxygen concentrations in both gaseous and dissolved forms by Nock et al. (2008b). Brennan et al. (2014) have successfully gathered studies on oxygen control of cells and tissues within microfluidic systems, which play a significant role in controlling oxygen tension which impacts cellular function and behavior.

Ammonia dissolved in an aqueous sample was extracted and sensed by using superhydrophobic virtual walls integrated with a microfluid chip by Raj et al. (2021a). Ammonia gas in low concentration has been measured by quantifying the electrolyte concentration in Timmer et al. (2006a) study. Paknahad et al. (2016a) developed a breath analyzer with the goal of detecting disease biomarkers. They were able to detect methanol, ethanol, and acetone in mixtures with a low concentration of 30 ppm. In another study, the effect of microchannel properties, including the channel coating and channel shape and dimensions, was studied on multiple target analytes including methanol, ethanol, and acetone (Paknahad et al., 2017b). Paknahad et al. (2012a) showed that simultaneous detection of important biomarkers such as acetone, hydrogen, benzene, and ethanol can be achieved by utilizing a system comprising a microfluidic channel with a semiconductor gas sensor. Using a novel thin film sensor with all electrochemical components combined in a multilayered, planar structure, (Cha et al., 2010) successfully created a microfluidic NO detection device which is crucial to numerous physiological processes.

3.3.2 Detector types

Different detector types have been employed for the detection of gases important in biological applications. The literature shows that the focus is on chemo-resistive (metal oxides) and optical gas detectors. Besides these two detection methods, electrochemical gas sensing has also been employed in a few cases. Paknahad et al. (2017b) have used tin-based metal oxide semiconductors as their sensing material for the detection of different biomarkers such as methanol, ethanol, and acetone (Figures 11A, B). This detector type is based upon the change in resistance of the sensing layer once it gets in contact with different gases (Paknahad et al., 2017b). Aghaseyedi et al. (2022) simulated gas flow in both serpentine and simple microchannels to determine the optimal microchannel configuration for enhancing gas selectivity using COMSOL Multiphysics. Through simulations they discovered that simple microchannel shows more response but less selectivity in comparison with serpentine microchannel. The optimal serpentine microchannel was fabricated and both acetone and ethanol were detected selectively and accurately using this MOS microfluidic-based gas sensor (Aghaseyedi et al., 2022).

FIGURE 11
www.frontiersin.org

FIGURE 11. (A) Schematic of a basic MOS gas sensor, (B) Equivalent electrical circuit for the MOS sensor (Paknahad et al., 2017b). Reprinted with permission from Elsevier.

Ammonia, an important biomarker, has been measured using two methods in the literature, optical and electrochemical methods. The optical method developed by Raj et al. (2021a) is based on gathering spectroscopic data from the sample. With aim of detecting ammonia in breath, Timmer et al. (2006a) used an electrolyte conductivity sensor besides a gas sampler and a selector. Oxygen sensing has been done using the optical method. Nock et al. (2008b) have used fluorescent dye-based optical sensing for detecting oxygen in the LOC devices application area.

3.3.3 Fabrication methods

In Paknahad et al. (2017b) studies a commercial thick film metal oxide sensing pallet and a thick film thermo-resistor micro-heater are deposited on opposing surfaces of a millimetre-scale ceramic substrate to make a chemo-resistor (MOS sensor). The microchannels were either 3D printed or made using CO2 laser ablation and micromachining. Raj et al. (2021a) have fabricated a novel microchip using adhesive tape and adding hydrophobic silica gel. In Grate et al. (2019a) study fabrication of the oxygen sensor was done by hot embossing polystyrene against a glass-backed PDMS structure which created the pore network device in polystyrene. Nock et al. fabricated fluorescence-based oxygen sensors by using spin-coating and dry-etching methods with PDMS stamps (Raj et al., 2021a). In the process of NO sensor fabrication, 1) PE insulating tape, 2) pAu/ITO electrode, 3) TeflonAF-treated Celgard membrane, 4) Nuclepore membrane, 5) Durapore membrane filter, 6) HybriWell chamber, 7) KCl/HCl internal solution, 8) Ag/AgCl wire was used to develop a thin planar configuration (Figure 12). Also, the microchannel was fabricated using the soft lithography method (Cha et al., 2010).

FIGURE 12
www.frontiersin.org

FIGURE 12. (A) Schematic representation of the sensor microchip fabrication (Raj et al., 2021a), (B) Fabrication of NO sensor (Cha et al., 2010). Reprinted with permission from ACS.

4 Summary tables for microfluidic platforms integrated gas sesnors

Supplementary Tables S1-S3 summarize the fabricated microfluidic platforms integrated gas sesnors utilizing different detection techniques and target analytes for environment, safety, and health monitoring.

5 Challenges and outlook

Microfluidic integrated gas sensors have garnered significant interest in recent years due to their potential to revolutionize smart analyte detection in various applications, such as environmental monitoring, healthcare, industrial process control, and food safety. These sensors offer several advantages, including rapid analysis, miniaturization, reduced sample volumes, and the ability to detect multiple analytes simultaneously. However, they also face several challenges and issues that need to be addressed to realize their full potential. Here we cover some of the key issues, challenges, and the outlook for microfluidic integrated gas sensors.

Microfluidic gas sensors require seamless integration of different components, such as microfluidic channels, gas chambers, and sensing elements, onto a small chip. One of the primary challenges in microfluidic gas sensors is achieving high levels of miniaturization while maintaining optimal performance. Achieving high sensitivity and selectivity at low concentrations of target analytes in complex gas mixtures while discriminating against interference from other gases is one of the significant challenges. Improving the selectivity of the sensors is essential to ensure accurate and reliable analyte detection.

The other challenge is selecting appropriate materials with high chemical resistance and low gas permeability which is crucial for long-term sensor stability and accuracy. The materials used in microfluidic devices should be compatible with the target analytes to prevent chemical reactions or adsorption that could lead to false readings or sensor degradation.

For portable and battery-operated applications, minimizing power consumption is critical. Developing energy-efficient sensing mechanisms and signal processing techniques is vital to extend the sensor’s operational lifetime and reduce its environmental impact.

The widespread adoption of microfluidic gas sensors depends on their cost-effectiveness. Reducing production costs, optimizing fabrication processes, and using affordable materials are essential to make these sensors more accessible to various industries and applications. There are couple of benefits derived from utilizing microfluidic integrated gas sensors in real-world scenarios to optimize industrial processes, and improving health monitoring, resulting in reduced healthcare expenses and increased workplace safety.

Some factors to consider in relation to the economic aspects of adopting microfluidic integrated gas sensors are expenses related to the design, and manufacturing of the microfluidic integrated gas sensors associated with acquiring the necessary components such as microfluidic chips, sensing elements, electronic components, also power requirements, including power for the microfluidic systems and associated electronics, as well as expenses related to calibration to maintain sensor accuracy and reliability.

Despite the challenges, the outlook for microfluidic integrated gas sensors is promising. Continuous research and advancements in materials science, microfabrication techniques, and sensing technologies are expected to overcome many of the existing issues. The integration of microfluidic gas sensors with other smart technologies, such as wireless communication and internet of things (IoT) platforms, will enable remote and interconnected monitoring systems. This will find applications in smart cities, environmental monitoring networks, and wearable health devices. Moreover, the capability to detect multiple analytes simultaneously will further enhance the utility of microfluidic gas sensors in various industries, enabling comprehensive and multifaceted analysis.

Overall, with ongoing research and interdisciplinary collaborations, microfluidic integrated gas sensors are likely to play a significant role in the future of smart analyte detection, revolutionizing various sectors and improving the quality of life.

6 Conclusion

This systematic review paper focuses on microfluidic gas sensors published after 1980. It provides an overview of different types of microfluidic gas sensors and their corresponding performance metrics. The papers were categorized into three sections: environment, safety, and health, based on their respective application areas. Within each application area, the articles were analyzed with respect to detector types, target analytes, and fabrication methods.

Microfluidic gas sensors have proven valuable for environmental applications, enabling in-door and on-site measurements. They play a crucial role in ensuring the safety of individuals and workers by monitoring and detecting gases in various living and working environments. Furthermore, microfluidic gas sensors have contributed to the health sector by offering selective, sensitive, and rapid biomarker detection systems.

Conventional metal-oxide semiconductor (MOS) sensors often suffer from drift issues caused by chemical reactions. The emergence of microfluidic MOS sensors has given rise to a new generation of sensors that detect analytes based on their physical properties, potentially resolving the drifting issues. Computational fluid dynamics (CFD) simulations are utilized to optimize channel geometries by modifying dimensions, altering directions, and introducing nanofeatures. Surface coatings with substances like graphene dots and adjustment of surface polarity have also been found to impact sensor performance. Machine learning techniques have been employed in conjunction with MOS sensors to train models based on sensor data, allowing for the classification of different analytes without direct operator intervention.

In addition to MOS sensors, there has been significant interest in integrating various optical sensors, such as gas chromatography-mass spectrometry (GC-MS), chemiluminescence (CL), fluorescence (FL), optical absorption spectroscopy (OAS), photoionization detection (PID), and surface-enhanced Raman spectroscopy (SERS), into microfluidic platforms. Conventional PID sensors, like those used for formaldehyde detection, may struggle to detect analytes with high ionization energy. Microfluidic high-density PID (HDPID) sensors have been developed to address this limitation, enabling the detection of various analytes with low power consumption. Microfluidic SERS gas sensors offer continuous detection of analyte molecules released from explosions, toxic airborne compounds, and environmental contaminants at sub-ppm levels.

Author contributions

AY: Conceptualization, Investigation, Visualization, Writing–original draft. KY: Conceptualization, Investigation, Visualization, Writing–original draft. NT: Resources, Writing–review and editing. SF: Writing–review and editing. MH: Funding acquisition, Supervision, Project administration, Writing–review and editing.

Funding

The author(s) declare financial support was received for the research, authorship, and/or publication of this article. This work was supported by the Discovery Grant (RGPIN-2017-04407) from the Natural Sciences and Engineering Research Council (NSERC) of Canada.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fchem.2023.1267187/full#supplementary-material

References

Abbyad, P., Dangla, R., Alexandrou, A., and Baroud, C. N. (2011). Rails and anchors: Guiding and trapping droplet microreactors in two dimensions. Lab. Chip 11 (5), 813–821. doi:10.1039/c0lc00104j

PubMed Abstract | CrossRef Full Text | Google Scholar

Abraham, N., Krishnakumar, R. R., Unni, C., and Philip, D. (2019). Simulation studies on the responses of ZnO-CuO/CNT nanocomposite based SAW sensor to various volatile organic chemicals. J. Sci. Adv. Mater. Devices 4 (1), 125–131. doi:10.1016/j.jsamd.2018.12.006

CrossRef Full Text | Google Scholar

Aghaseyedi, M., Salehi, A., Valijam, S., and Shooshtari, M. (2022). Gas selectivity enhancement using serpentine microchannel shaped with optimum dimensions in microfluidic-based gas sensor. Micromachines 13 (9), 1504. doi:10.3390/MI13091504

PubMed Abstract | CrossRef Full Text | Google Scholar

Aliyu, F., Al-Shaboti, M., Garba, Y., Sheltami, T., Barnawi, A., and Morsy, M. A. (2015). Hydrogen sulfide (h2s) gas safety system for oil drilling sites using wireless sensor network. Procedia Comput. Sci. 63, 499–504. doi:10.1016/j.procs.2015.08.375

CrossRef Full Text | Google Scholar

Anjum, S. R., Narwade, V. N., Bogle, K. A., and Khairnar, R. S. (2018). Graphite doped Hydroxyapatite nanoceramic: Selective alcohol sensor. Nano-Structures Nano-Objects 14, 98–105. doi:10.1016/j.nanoso.2018.01.010

CrossRef Full Text | Google Scholar

Antony, R., Giri Nandagopal, M. S., Sreekumar, N., and Selvaraju, N. (2014a). Detection principles and development of microfluidic sensors in the last decade. Microsyst. Technol. 20 (6), 1051–1061. doi:10.1007/s00542-014-2165-0

CrossRef Full Text | Google Scholar

Antony, R., Giri Nandagopal, M. S., Sreekumar, N., and Selvaraju, N. (2014b). Detection principles and development of microfluidic sensors in the last decade. Microsyst. Technol. 20 (6), 1051–1061. doi:10.1007/s00542-014-2165-0

CrossRef Full Text | Google Scholar

Arasaradnam, R. P., Covington, J. A., Harmston, C., and Nwokolo, C. U. (2014). Review article: Next generation diagnostic modalities in gastroenterology - gas phase volatile compound biomarker detection. Aliment. Pharmacol. Ther. 39 (8), 780–789. doi:10.1111/apt.12657

PubMed Abstract | CrossRef Full Text | Google Scholar

Atkinson, R. (2000). Atmospheric chemistry of VOCs and NOx. Atmos. Environ. 34 (12), 2063–2101. doi:10.1016/S1352-2310(99)00460-4

CrossRef Full Text | Google Scholar

Barbosa, A. J. M., Oliveira, A. R., and Roque, A. C. A. (2018). Protein-and peptide-based biosensors in artificial olfaction. Trends Biotechnol. 36 (12), 1244–1258. doi:10.1016/j.tibtech.2018.07.004

PubMed Abstract | CrossRef Full Text | Google Scholar

Barriault, M., Alexander, I., Tasnim, N., O’Brien, A., Najjaran, H., and Hoorfar, M. (2021). Classification and regression of binary hydrocarbon mixtures using single metal oxide semiconductor sensor with application to natural gas detection. Sens. Actuators B Chem. 326, 129012. doi:10.1016/j.snb.2020.129012

CrossRef Full Text | Google Scholar

Bavcon Kralj, M., Franko, M., and Trebše, P. (2007). Photodegradation of organophosphorus insecticides – investigations of products and their toxicity using gas chromatography–mass spectrometry and AChE-thermal lens spectrometric bioassay. Chemosphere 67 (1), 99–107. doi:10.1016/j.chemosphere.2006.09.039

PubMed Abstract | CrossRef Full Text | Google Scholar

Becker, A., Andrikopoulou, C., Bernhardt, P., Trocquet, C., and Le Calvé, S. (2020). On-Line gaseous formaldehyde detection based on a closed-microfluidic-circuit analysis. Chemosensors 8 (3), 57. doi:10.3390/chemosensors8030057

CrossRef Full Text | Google Scholar

Becker, T., Mühlberger, S., Braunmühl, C. B.-V., Müller, G., Meckes, A., and Benecke, W. (2001a). Microreactors and microfluidic systems: An innovative approach to gas sensing using tin oxide-based gas sensors. Sens. Actuators B Chem. 77 (1), 48–54. doi:10.1016/S0925-4005(01)00671-2

CrossRef Full Text | Google Scholar

Becker, T., Mühlberger, S., Braunmühl, C. B.-V., Müller, G., Meckes, A., and Benecke, W. (2001b). Microreactors and microfluidic systems: An innovative approach to gas sensing using tin oxide-based gas sensors. Sens. Actuators B Chem. 77 (1), 48–54. doi:10.1016/S0925-4005(01)00671-2

CrossRef Full Text | Google Scholar

ben Youssef, I., Sarry, F., Nysten, B., Alexieva, G., Strashilov, V., Kolev, I., et al. (2016). Growth and toxic gas sensing properties of poly(urethaneimide) thin films. Talanta 153, 145–151. doi:10.1016/j.talanta.2016.03.021

PubMed Abstract | CrossRef Full Text | Google Scholar

Bhalla, N., Jolly, P., Formisano, N., and Estrela, P. (2016). Introduction to biosensors. Essays Biochem. 60 (1), 1–8. doi:10.1042/EBC20150001

PubMed Abstract | CrossRef Full Text | Google Scholar

Bogue, R. (2015). Detecting gases with light: A review of optical gas sensor technologies. Sens. Rev. 35, 133–140. doi:10.1108/SR-09-2014-696

CrossRef Full Text | Google Scholar

Brennan, M. D., Rexius-Hall, M. L., Elgass, L. J., and Eddington, D. T. (2014). Oxygen control with microfluidics. Lab. Chip 14 (22), 4305–4318. doi:10.1039/C4LC00853G

PubMed Abstract | CrossRef Full Text | Google Scholar

Buckley, D. J., Black, N. C. G., Castanon, E. G., Melios, C., Hardman, M., and Kazakova, O. (2020). Frontiers of graphene and 2D material-based gas sensors for environmental monitoring. 2d Mater 7 (3), 032002. doi:10.1088/2053-1583/ab7bc5

CrossRef Full Text | Google Scholar

Bulbul, A., Hsieh, H.-C., and Kim, H. (2014). “Microfluidic bubble-based gas sensor,” in 2014 IEEE 27th International Conference on Micro Electro Mechanical Systems (MEMS), San Francisco, USA, 26-30 January 2014, 226–229.

CrossRef Full Text | Google Scholar

Bulbul, A., and Kim, H. (2015a). A bubble-based microfluidic gas sensor for gas chromatographs. Lab. Chip 15 (1), 94–104. doi:10.1039/c4lc00892h

PubMed Abstract | CrossRef Full Text | Google Scholar

Bulbul, A., and Kim, H. (2015b). A bubble-based microfluidic gas sensor for gas chromatographs. Lab. Chip 15 (1), 94–104. doi:10.1039/c4lc00892h

PubMed Abstract | CrossRef Full Text | Google Scholar

Bunge, F., van den Driesche, S., Waespy, M., Radtke, A., Belge, G., Kelm, S., et al. (2019a). Microfluidic oxygen sensor system as a tool to monitor the metabolism of mammalian cells. Sens. Actuators B Chem. 289, 24–31. doi:10.1016/J.SNB.2019.03.041

CrossRef Full Text | Google Scholar

Bunge, F., van den Driesche, S., Waespy, M., Radtke, A., Belge, G., Kelm, S., et al. (2019b). Microfluidic oxygen sensor system as a tool to monitor the metabolism of mammalian cells. Sens. Actuators B Chem. 289, 24–31. doi:10.1016/j.snb.2019.03.041

CrossRef Full Text | Google Scholar

Cha, W., Tung, Y. C., Meyerhoff, M. E., and Takayama, S. (2010). Patterned electrode-based amperometric gas sensor for direct nitric oxide detection within microfluidic devices. Anal. Chem. 82 (8), 3300–3305. doi:10.1021/ac100085w

PubMed Abstract | CrossRef Full Text | Google Scholar

Chatterjee, S., Shkondin, E., Takayama, O., Fisher, A., Fraiwan, A., Gurkan, U. A., et al. (2020). Hydrogen gas sensing using aluminum doped ZnO metasurfaces. Nanoscale Adv. 2 (8), 3452–3459. doi:10.1039/D0NA00289E

PubMed Abstract | CrossRef Full Text | Google Scholar

Chen, G., Zheng, J., Liu, L., and Xu, L. (2019). Application of microfluidics in wearable devices. Small Methods 3 (12), 1900688. doi:10.1002/smtd.201900688

CrossRef Full Text | Google Scholar

Cooney, C. G., and Towe, B. C. (2004). Evaluation of microfluidic blood gas sensors that combine microdialysis and optical monitoring. Med. Biol. Eng. Comput. 42 (5), 720–724. doi:10.1007/BF02347556

PubMed Abstract | CrossRef Full Text | Google Scholar

Cubillas, A. M., Lazaro, J. M., Conde, O. M., Petrovich, M. N., and Lopez-Higuera, J. M. (2009). Multi-Line fit model for the detection of methane at ν2 + 2ν3 band using hollow-core photonic bandgap fibres. Sensors 9 (1), 490–502. doi:10.3390/s90100490

PubMed Abstract | CrossRef Full Text | Google Scholar

Demello, A. J. (2006). Control and detection of chemical reactions in microfluidic systems. Nature 442 (7101), 394–402. doi:10.1038/nature05062

PubMed Abstract | CrossRef Full Text | Google Scholar

Dey, A. (2017). Semiconductor metal oxide gas sensors: A review. A Rev. 229, 206–217. doi:10.1016/j.mseb.2017.12.036

CrossRef Full Text | Google Scholar

Directive, C. (2000). 69/EC of 16 November 2000 relating to limit values for benzene and carbon monoxide in ambient air. Official J. Eur. Communities, No L 313, 12–13.

Google Scholar

Dixit, K., Fardindoost, S., Ravishankara, A., Tasnim, N., and Hoorfar, M. (2021a). Exhaled breath analysis for diabetes diagnosis and monitoring: Relevance, challenges and possibilities. Biosensors 11 (12), 476. doi:10.3390/BIOS11120476

PubMed Abstract | CrossRef Full Text | Google Scholar

Dixit, K., Fardindoost, S., Ravishankara, A., Tasnim, N., and Hoorfar, M. (2021b). Exhaled breath analysis for diabetes diagnosis and monitoring: Relevance, challenges and possibilities. Biosensors 11 (12), 476. doi:10.3390/BIOS11120476

PubMed Abstract | CrossRef Full Text | Google Scholar

Dow, A. B. A., Sklorz, A., and Lang, W. (2011). A microfluidic preconcentrator for enhanced monitoring of ethylene gas. Sens. Actuators A Phys. 167 (2), 226–230. doi:10.1016/j.sna.2011.01.019

CrossRef Full Text | Google Scholar

Duarte, K., Justino, C. I. L., Freitas, A. C., Duarte, A. C., and Rocha-Santos, T. A. P. (2014). Direct-reading methods for analysis of volatile organic compounds and nanoparticles in workplace air. TrAC Trends Anal. Chem. 53, 21–32. doi:10.1016/j.trac.2013.08.008

CrossRef Full Text | Google Scholar

Dubnikova, F., Kosloff, R., Almog, J., Zeiri, Y., Boese, R., Itzhaky, H., et al. (2005). Decomposition of triacetone triperoxide is an entropic explosion. J. Am. Chem. Soc. 127 (4), 1146–1159. doi:10.1021/ja0464903

PubMed Abstract | CrossRef Full Text | Google Scholar

Ebnali-Heidari, M., Koohi-Kamali, F., Ebnali-Heidari, A., Moravvej-Farshi, M. K., and Kuhlmey, B. T. (2014). Designing tunable microstructure spectroscopic gas sensor using optofluidic hollow-core photonic crystal fiber. IEEE J. Quantum Electron 50 (12), 1–8. doi:10.1109/JQE.2014.2362353

CrossRef Full Text | Google Scholar

Freeman, R. R., and Wentworth, W. E. (1971). Helium photoionization detector utilizing a microwave discharge source. Anal. Chem. 43 (14), 1987–1991. doi:10.1021/ac60308a003

CrossRef Full Text | Google Scholar

Gao, Z.-X., Li, H.-F., Liu, J., and Lin, J.-M. (2008). A simple microfluidic chlorine gas sensor based on gas–liquid chemiluminescence of luminol-chlorine system. Anal. Chim. Acta 622 (1), 143–149. doi:10.1016/j.aca.2008.05.067

PubMed Abstract | CrossRef Full Text | Google Scholar

Gaun, , (2020). Gas-sensing performances of metal oxide nanostructures for detecting dissolved gases: A mini review. Front. Chem.Sec. Nanosci. 8–2020. doi:10.3389/fchem.2020.00076

CrossRef Full Text | Google Scholar

Ghaderahmadi, S., Kamkar, M., Tasnim, N., Arjmand, M., and Hoorfar, M. (2021a). A review of low-temperature H 2 S gas sensors: Fabrication and mechanism. New J. Chem. 45, 17727–17752. doi:10.1039/d1nj02468j

CrossRef Full Text | Google Scholar

Ghaderahmadi, S., Kamkar, M., Tasnim, N., Arjmand, M., and Hoorfar, M. (2021b). A review of low-temperature H 2 S gas sensors: Fabrication and mechanism. New J. Chem. 45, 17727–17752. doi:10.1039/d1nj02468j

CrossRef Full Text | Google Scholar

Ghafarinia, V., and Hossein-Babaei, F. (2011). Single sensor gas analysis using a microfluidic channel. Key Eng. Mater 495, 302–305. doi:10.4028/www.scientific.net/kem.495.302

CrossRef Full Text | Google Scholar

Ghazi, M., Janfaza, S., Tahmooressi, H., Ravishankara, A., Earl, E., Tasnim, N., et al. (2021a). Enhanced selectivity of microfluidic gas sensors by modifying microchannel geometry and surface chemistry with graphene quantum dots. Sens. Actuators B Chem. 342, 130050. doi:10.1016/j.snb.2021.130050

CrossRef Full Text | Google Scholar

Ghazi, M., Janfaza, S., Tahmooressi, H., Ravishankara, A., Earl, E., Tasnim, N., et al. (2021b). Enhanced selectivity of microfluidic gas sensors by modifying microchannel geometry and surface chemistry with graphene quantum dots. Sens. Actuators B Chem. 342, 130050. doi:10.1016/j.snb.2021.130050

CrossRef Full Text | Google Scholar

Ghazi, M., Janfaza, S., Tahmooressi, H., Ravishankara, A., Earl, E., Tasnim, N., et al. (2021c). Enhanced selectivity of microfluidic gas sensors by modifying microchannel geometry and surface chemistry with graphene quantum dots. Sens. Actuators B Chem. 342, 130050. doi:10.1016/j.snb.2021.130050

CrossRef Full Text | Google Scholar

Ghazi, M., Janfaza, S., Tahmooressi, H., Ravishankara, A., Earl, E., Tasnim, N., et al. (2021d). Enhanced selectivity of microfluidic gas sensors by modifying microchannel geometry and surface chemistry with graphene quantum dots. Sens. Actuators B Chem. 342, 130050. doi:10.1016/j.snb.2021.130050

CrossRef Full Text | Google Scholar

Ghazi, M., Janfaza, S., Tahmooressi, H., Tasnim, N., and Hoorfar, M. (2022a). Selective detection of VOCs using microfluidic gas sensor with embedded cylindrical microfeatures coated with graphene oxide. J. Hazard Mater 424, 127566. doi:10.1016/J.JHAZMAT.2021.127566

PubMed Abstract | CrossRef Full Text | Google Scholar

Ghazi, M., Janfaza, S., Tahmooressi, H., Tasnim, N., and Hoorfar, M. (2022b). Selective detection of VOCs using microfluidic gas sensor with embedded cylindrical microfeatures coated with graphene oxide. J. Hazard Mater 424, 127566. doi:10.1016/j.jhazmat.2021.127566

PubMed Abstract | CrossRef Full Text | Google Scholar

Ghazi, M., Janfaza, S., Tahmooressi, H., Tasnim, N., and Hoorfar, M. (2022c). Selective detection of VOCs using microfluidic gas sensor with embedded cylindrical microfeatures coated with graphene oxide. J. Hazard Mater 424, 127566. doi:10.1016/j.jhazmat.2021.127566

PubMed Abstract | CrossRef Full Text | Google Scholar

Ghazi, M., Tasnim, N., and Hoorfar, M. (2022d). Selective monitoring of natural gas sulphur-based odorant mixture of t-butyl mercaptan and methyl ethyl sulphide using an array of microfluidic gas sensors. J. Hazard Mater 438, 129548. doi:10.1016/j.jhazmat.2022.129548

PubMed Abstract | CrossRef Full Text | Google Scholar

Gouma, P. I., Stanacevic, M., and Simon, S. (2015). An overview of the translation of selective semiconducting gas sensors from first results to automotive exhaust gas monitors to a platform for breath-based diagnostics. Transl. Mater. Res. 2 (4), 045001. doi:10.1088/2053-1613/2/4/045001

CrossRef Full Text | Google Scholar

Grant, W. B., Kagann, R. H., and McClenny, W. A. (1992). Optical remote measurement of toxic gases. J. Air Waste Manage Assoc. 42 (1), 18–30. doi:10.1080/10473289.1992.10466965

PubMed Abstract | CrossRef Full Text | Google Scholar

Gras, R., Luong, J., Monagle, M., and Winniford, B. (2006). Gas chromatographic applications with the dielectric barrier discharge detector. J. Chromatogr. Sci. 44 (2), 101–107. doi:10.1093/chromsci/44.2.101

PubMed Abstract | CrossRef Full Text | Google Scholar

Grate, J. W., Liu, B., Kelly, R. T., Anheier, N. C., and Schmidt, T. M. (2019a). Microfluidic sensors with impregnated fluorophores for simultaneous imaging of spatial structure and chemical oxygen gradients. ACS Sens. 4 (2), 317–325. doi:10.1021/acssensors.8b00924

PubMed Abstract | CrossRef Full Text | Google Scholar

Grate, J. W., Liu, B., Kelly, R. T., Anheier, N. C., and Schmidt, T. M. (2019b). Microfluidic sensors with impregnated fluorophores for simultaneous imaging of spatial structure and chemical oxygen gradients. ACS Sens. 4 (2), 317–325. doi:10.1021/acssensors.8b00924

PubMed Abstract | CrossRef Full Text | Google Scholar

Grist, S. M., Schmok, J. C., Andy Liu, M. C., Chrostowski, L., and Cheung, K. C. (2015a). Designing a microfluidic device with integrated ratiometric oxygen sensors for the long-term control and monitoring of chronic and cyclic hypoxia. Sensors 15, 20030–20052. doi:10.3390/S150820030

PubMed Abstract | CrossRef Full Text | Google Scholar

Grist, S. M., Schmok, J. C., Liu, M.-C. A., Chrostowski, L., and Cheung, K. C. (2015b). Designing a microfluidic device with integrated ratiometric oxygen sensors for the long-term control and monitoring of chronic and cyclic hypoxia. Sensors 15 (8), 20030–20052. doi:10.3390/s150820030

PubMed Abstract | CrossRef Full Text | Google Scholar

Grubisha, D. S., Lipert, R. J., Park, H.-Y., Driskell, J., and Porter, M. D. (2003). Femtomolar detection of prostate-specific antigen: An immunoassay based on surface-enhanced Raman scattering and immunogold labels. Anal. Chem. 75 (21), 5936–5943. doi:10.1021/ac034356f

PubMed Abstract | CrossRef Full Text | Google Scholar

Guillam, M.-T., Thomas, N., Nedellec, V., Derbez, M., Kirchner, S., Pédrono, G., et al. (2010). Children’s indoor leisure activities in France: Time budget data for indoor air risk assessment. Hum. Ecol. risk Assess. 16 (5), 977–988. doi:10.1080/10807039.2010.512237

CrossRef Full Text | Google Scholar

Guo, X.-L., Chen, Y., Jiang, H.-L., Qiu, X.-B., and Yu, D.-L. (2018a). Smartphone-based microfluidic colorimetric sensor for gaseous formaldehyde determination with high sensitivity and selectivity. Sensors 18 (9), 3141. doi:10.3390/s18093141

PubMed Abstract | CrossRef Full Text | Google Scholar

Guo, Y., Xue, S., Dîrtu, M. M., and Garcia, Y. (2018b). A versatile iron (II)-based colorimetric sensor for the vapor-phase detection of alcohols and toxic gases. J. Mater Chem. C Mater 6 (15), 3895–3900. doi:10.1039/c8tc00375k

CrossRef Full Text | Google Scholar

Gupta Chatterjee, S., Chatterjee, S., Ray, A. K., and Chakraborty, A. K. (2015). Graphene–metal oxide nanohybrids for toxic gas sensor: A review. Sens. Actuators B Chem. 221, 1170–1181. doi:10.1016/j.snb.2015.07.070

CrossRef Full Text | Google Scholar

Haynes, W. M. (2014). CRC handbook of chemistry and physics. Florida, United States: CRC Press.

Google Scholar

Hodgkinson, J., and Tatam, R. P. (2012). Optical gas sensing: A review. Meas. Sci. Technol. 24 (1), 012004. doi:10.1088/0957-0233/24/1/012004

CrossRef Full Text | Google Scholar

Hong, J. W., and Quake, S. R. (2003). Integrated nanoliter systems. Nat. Biotechnol. 21 (10), 1179–1183. doi:10.1038/nbt871

PubMed Abstract | CrossRef Full Text | Google Scholar

Hong, S., Wu, M., Hong, Y., Jeong, Y., Jung, G., Shin, W., et al. (2021). FET-type gas sensors: A review. Sens. Actuators B Chem. 330, 129240. doi:10.1016/j.snb.2020.129240

CrossRef Full Text | Google Scholar

Hossein-Babaei, F., and Ghafarinia, V. (2010a). Gas analysis by monitoring molecular diffusion in a microfluidic channel. Anal. Chem. 82 (19), 8349–8355. doi:10.1021/ac101767r

PubMed Abstract | CrossRef Full Text | Google Scholar

Hossein-Babaei, F., and Ghafarinia, V. (2010b). Gas analysis by monitoring molecular diffusion in a microfluidic channel. Anal. Chem. 82 (19), 8349–8355. doi:10.1021/ac101767r

PubMed Abstract | CrossRef Full Text | Google Scholar

Hossein-Babaei, F., Hooshyar Zare, A., Ghafarinia, V., and Erfantalab, S. (2015). Identifying volatile organic compounds by determining their diffusion and surface adsorption parameters in microfluidic channels. Sens. Actuators B Chem. 220, 607–613. doi:10.1016/j.snb.2015.06.014

CrossRef Full Text | Google Scholar

Hossein-Babaei, F., Paknahad, M., and Ghafarinia, V. (2012). A miniature gas analyzer made by integrating a chemoresistor with a microchannel. Lab. Chip 12 (10), 1874–1880. doi:10.1039/c2lc00035k

PubMed Abstract | CrossRef Full Text | Google Scholar

Janfaza, S., Kim, E., O’Brien, A., Najjaran, H., Nikkhah, M., Alizadeh, T., et al. (2019a). A nanostructured microfluidic artificial olfaction for organic vapors recognition. Sci. Rep. 9 (1), 19051. doi:10.1038/s41598-019-55672-z

PubMed Abstract | CrossRef Full Text | Google Scholar

Janfaza, S., Kim, E., O’Brien, A., Najjaran, H., Nikkhah, M., Alizadeh, T., et al. (2019b). A nanostructured microfluidic artificial olfaction for organic vapors recognition. Sci. Rep. 9 (1), 19051–19058. doi:10.1038/s41598-019-55672-z

PubMed Abstract | CrossRef Full Text | Google Scholar

Jung, G., Hong, Y., Hong, S., Jang, D., Jeong, Y., Shin, W., et al. (2021). A low-power embedded poly-Si micro-heater for gas sensor platform based on a FET transducer and its application for NO2 sensing. Sens. Actuators B Chem. 334, 129642. doi:10.1016/j.snb.2021.129642

CrossRef Full Text | Google Scholar

Jung, G., Jeong, Y., Hong, Y., Wu, M., Hong, S., Shin, W., et al. (2020). SO2 gas sensing characteristics of FET-and resistor-type gas sensors having WO3 as sensing material. Solid State Electron 165, 107747. doi:10.1016/j.sse.2019.107747

CrossRef Full Text | Google Scholar

Kampa, M., and Castanas, E. (2008). Human health effects of air pollution. Environ. Pollut. 151 (2), 362–367. doi:10.1016/j.envpol.2007.06.012

PubMed Abstract | CrossRef Full Text | Google Scholar

Kim, D., Kim, S., and Kim, S. (2018). Development of novel complementary metal-oxide semiconductor-based colorimetric sensors for rapid detection of industrially important gases. Sens. Actuators B Chem. 265, 600–608. doi:10.1016/j.snb.2018.03.101

CrossRef Full Text | Google Scholar

Kladsomboon, S., Thippakorn, C., and Seesaard, T. (2018). Development of organic-inorganic hybrid optical gas sensors for the non-invasive monitoring of pathogenic bacteria. Sensors 18 (10), 3189. doi:10.3390/s18103189

PubMed Abstract | CrossRef Full Text | Google Scholar

Kumar, S., Pavelyev, V., Mishra, P., Tripathi, N., Sharma, P., and Calle, F. (2020). A review on 2D transition metal di-chalcogenides and metal oxide nanostructures based NO2 gas sensors. Mater. Sci. Semicond. Process. 107, 104865. doi:10.1016/j.mssp.2019.104865

CrossRef Full Text | Google Scholar

Kwiatkowski, A., Chludziński, T., and Smulko, J. (2018). Portable exhaled breath analyzer employing fluctuation-enhanced gas sensing method in resistive gas sensors. Metrology Meas. Syst. 25 (3), 551–560. doi:10.24425/123892

CrossRef Full Text | Google Scholar

Lai, W.-C., Chakravarty, S., Wang, X., Lin, C., and Chen, R. T. (2011). On-chip methane sensing by near-IR absorption signatures in a photonic crystal slot waveguide. Opt. Lett. 36 (6), 984–986. doi:10.1364/ol.36.000984

PubMed Abstract | CrossRef Full Text | Google Scholar

Lee, S. H., Lim, J. H., Park, J., Hong, S., and Park, T. H. (2015a). Bioelectronic nose combined with a microfluidic system for the detection of gaseous trimethylamine. Biosens. Bioelectron. 71, 179–185. doi:10.1016/J.BIOS.2015.04.033

PubMed Abstract | CrossRef Full Text | Google Scholar

Lee, S. H., Lim, J. H., Park, J., Hong, S., and Park, T. H. (2015b). Bioelectronic nose combined with a microfluidic system for the detection of gaseous trimethylamine. Biosens. Bioelectron. 71, 179–185. doi:10.1016/j.bios.2015.04.033

PubMed Abstract | CrossRef Full Text | Google Scholar

Lee, S. H., Lim, J. H., Park, J., Hong, S., and Park, T. H. (2015c). Bioelectronic nose combined with a microfluidic system for the detection of gaseous trimethylamine. Biosens. Bioelectron. 71, 179–185. doi:10.1016/j.bios.2015.04.033

PubMed Abstract | CrossRef Full Text | Google Scholar

Li, H., Mu, X., Yang, Y., and Mason, A. J. (2014a). Low power multimode electrochemical gas sensor array system for wearable health and safety monitoring. IEEE Sens. J. 14 (10), 3391–3399. doi:10.1109/JSEN.2014.2332278

CrossRef Full Text | Google Scholar

Li, H., Mu, X., Yang, Y., and Mason, A. J. (2014b). Low power multimode electrochemical gas sensor array system for wearable health and safety monitoring. IEEE Sens. J. 14 (10), 3391–3399. doi:10.1109/JSEN.2014.2332278

CrossRef Full Text | Google Scholar

Li, M. W.-H., Ghosh, A., Sharma, R., Zhu, H., and Fan, X. (2021). Integrated microfluidic helium discharge photoionization detectors. Sens. Actuators B Chem. 332, 129504. doi:10.1016/j.snb.2021.129504

CrossRef Full Text | Google Scholar

Liu, L., Zhang, G., Wang, Z., Yuan, J., Tan, S., and Li, Y. (2022). Mo2C-Based microfluidic gas sensor detects SF6 decomposition components: A first-principles study. Chemosensors 10 (9), 368. doi:10.3390/CHEMOSENSORS10090368

CrossRef Full Text | Google Scholar

Liu, X., Cheng, S., Liu, H., Hu, S., Zhang, D., and Ning, H. (2012). A survey on gas sensing technology. Sensors 12 (7), 9635–9665. doi:10.3390/s120709635

PubMed Abstract | CrossRef Full Text | Google Scholar

Lu, C. J., and Zellers, E. T. (2002). Multi-adsorbent preconcentration/focusing module for portable-GC/microsensor-array analysis of complex vapor mixtures. Analyst 127 (8), 1061–1068. doi:10.1039/b111689d

PubMed Abstract | CrossRef Full Text | Google Scholar

Lungarella, G., Barni-Comparini, I., and Fonzi, L. (1984). Pulmonary changes induced in rabbits by long-term exposure to n-hexane. Arch. Toxicol. 55 (4), 224–228. doi:10.1007/BF00341015

PubMed Abstract | CrossRef Full Text | Google Scholar

Mahajan, S., and Jagtap, S. (2020). Metal-oxide semiconductors for carbon monoxide (CO) gas sensing: A review. Appl. Mater Today 18, 100483. doi:10.1016/j.apmt.2019.100483

CrossRef Full Text | Google Scholar

Majhi, S. M., Mirzaei, A., Navale, S., Kim, H. W., and Kim, S. S. (2021). Boosting the sensing properties of resistive-based gas sensors by irradiation techniques: A review. Nanoscale 13 (9), 4728–4757. doi:10.1039/d0nr08448d

PubMed Abstract | CrossRef Full Text | Google Scholar

Mariuta, D., Govindaraji, A., Colin, S., Barrot, C., Le Calvé, S., Korvink, J. G., et al. (2020). Optofluidic formaldehyde sensing: Towards on-chip integration. Micromachines (Basel) 11 (7), 673. doi:10.3390/mi11070673

PubMed Abstract | CrossRef Full Text | Google Scholar

Marquette, C. A., and Blum, L. J. (2006). Applications of the luminol chemiluminescent reaction in analytical chemistry. Anal. Bioanal. Chem. 385 (3), 546–554. doi:10.1007/s00216-006-0439-9

PubMed Abstract | CrossRef Full Text | Google Scholar

Martini, V., Bernardini, S., Bendahan, M., Aguir, K., Perrier, P., and Graur, I. (2010). Fabrication and characterization of gas detection microfluidic system. Procedia Eng. 5, 1188–1191. doi:10.1016/j.proeng.2010.09.324

CrossRef Full Text | Google Scholar

Martini, V., Bernardini, S., Bendahan, M., Aguir, K., Perrier, P., and Graur, I. (2012a). Microfluidic gas sensor with integrated pumping system. Sens. Actuators B Chem. 170, 45–50. doi:10.1016/j.snb.2011.01.011

CrossRef Full Text | Google Scholar

Martini, V., Bernardini, S., Bendahan, M., Aguir, K., Perrier, P., and Graur, I. (2012b). Microfluidic gas sensor with integrated pumping system. Sens. Actuators B Chem. 170, 45–50. doi:10.1016/j.snb.2011.01.011

CrossRef Full Text | Google Scholar

Martini, V., Bernardini, S., Bendahan, M., Aguir, K., Perrier, P., and Graur, I. (2012c). Microfluidic gas sensor with integrated pumping system. Sens. Actuators B Chem. 170, 45–50. doi:10.1016/j.snb.2011.01.011

CrossRef Full Text | Google Scholar

Meckes, A., Behrens, J., Kayser, O., Benecke, W., Becker, Th., and Müller, G. (1999). Microfluidic system for the integration and cyclic operation of gas sensors. Sens. Actuators A Phys. 76 (1), 478–483. doi:10.1016/S0924-4247(99)00060-6

CrossRef Full Text | Google Scholar

Ministry of the Environment, J. (2009). Environmental quality standards in Japan—air quality. Tokyo, Japan: Ministry of the Environment.

Google Scholar

Mohaghegh Montazeri, M., O’Brien, A., and Hoorfar, M. (2019). Understanding microfluidic-based gas detectors: A numerical model to investigate fundamental sensor operation, influencing phenomena and optimum geometries. Sens. Actuators B Chem. 300, 126904. doi:10.1016/j.snb.2019.126904

CrossRef Full Text | Google Scholar

Montazeri, M. M., (2017). “A sensor for nuisance sewer gas monitoring,” in 2017 IEEE SENSORS, Glassboro, NJ, USA, March 15, 2017 - March 17, 2017, 1–3.

CrossRef Full Text | Google Scholar

Moraes, T. A., Farrôco, M. J., Pontes, K., Bittencourt, M. F., Soares, B. G., and Souza, F. G. (2020). An optical-magnetic Material as a toxic gas filter and sensing device. RSC Adv. 10 (39), 23233–23244. doi:10.1039/d0ra00537a

PubMed Abstract | CrossRef Full Text | Google Scholar

Mortensen, N. A., Xiao, S., and Pedersen, J. (2008). Liquid-infiltrated photonic crystals: Enhanced light-matter interactions for lab-on-a-chip applications. Microfluid Nanofluidics 4 (1–2), 117–127. doi:10.1007/s10404-007-0203-2

CrossRef Full Text | Google Scholar

Mugherli, L., Lety-Stefanska, A., Landreau, N., Tomasi, R. F.-X., and Baroud, C. N. (2020). Quantifying the sol–gel process and detecting toxic gas in an array of anchored microfluidic droplets. Lab. Chip 20 (2), 236–243. doi:10.1039/c9lc00750d

PubMed Abstract | CrossRef Full Text | Google Scholar

Narwade, V. N., (2021). “Nanostructured hydroxyapatite biomaterial as gas sensor,” in Nanoscale processing (Amsterdam, Netherlands: Elsevier), 439–466.

CrossRef Full Text | Google Scholar

Nedjalkov, A., Meyer, J., Köhring, M., Doering, A., Angelmahr, M., Dahle, S., et al. (2016). Toxic gas emissions from damaged lithium ion batteries—analysis and safety enhancement solution. Batteries 2 (1), 5. doi:10.3390/batteries2010005

CrossRef Full Text | Google Scholar

Nock, V., Blaikie, R. J., and David, T. (2008a). Patterning, integration and characterisation of polymer optical oxygen sensors for microfluidic devices. Lab. Chip 8 (8), 1300–1307. doi:10.1039/B801879K

PubMed Abstract | CrossRef Full Text | Google Scholar

Nock, V., Blaikie, R. J., and David, T. (2008b). Patterning, integration and characterisation of polymer optical oxygen sensors for microfluidic devices. Lab. Chip 8 (8), 1300–1307. doi:10.1039/B801879K

PubMed Abstract | CrossRef Full Text | Google Scholar

Nock, V., Blaikie, R. J., and David, T. (2008c). Patterning, integration and characterisation of polymer optical oxygen sensors for microfluidic devices. Lab. Chip 8 (8), 1300–1307. doi:10.1039/b801879k

PubMed Abstract | CrossRef Full Text | Google Scholar

on Cancer, I. A. for R. (2004). IARC classifies formaldehyde as carcinogenic to humans. Press release 15.

Google Scholar

Paknahad, M., Ahmadi, A., Rousseau, J., Nejad, H. R., and Hoorfar, M. (2017a). On-chip electronic nose for wine tasting: A digital microfluidic approach. IEEE Sens. J. 17 (14), 4322–4329. doi:10.1109/JSEN.2017.2707525

CrossRef Full Text | Google Scholar

Paknahad, M., Bachhal, J. S., Ahmadi, A., and Hoorfar, M. (2017b). Characterization of channel coating and dimensions of microfluidic-based gas detectors. Sens. Actuators B Chem. 241, 55–64. doi:10.1016/J.SNB.2016.10.048

CrossRef Full Text | Google Scholar

Paknahad, M., Bachhal, J. S., Ahmadi, A., and Hoorfar, M. (2017c). Characterization of channel coating and dimensions of microfluidic-based gas detectors. Sens. Actuators B Chem. 241, 55–64. doi:10.1016/j.snb.2016.10.048

CrossRef Full Text | Google Scholar

Paknahad, M., Bachhal, J. S., Ahmadi, A., and Hoorfar, M. (2017d). Characterization of channel coating and dimensions of microfluidic-based gas detectors. Sens. Actuators B Chem. 241, 55–64. doi:10.1016/j.snb.2016.10.048

CrossRef Full Text | Google Scholar

Paknahad, M., Bachhal, J. S., Ahmadi, A., and Hoorfar, M. (2016a). Highly selective multi-target 3D-printed microfluidic-based breath analyzer. Proc. IEEE Int. Conf. Micro Electro Mech. Syst. (MEMS), 905–908. doi:10.1109/MEMSYS.2016.7421777

CrossRef Full Text | Google Scholar

Paknahad, M., Bachhal, J. S., Ahmadi, A., and Hoorfar, M. (2016b). “Highly selective multi-target 3D-printed microfluidic-based breath analyzer,” in 2016 IEEE 29th International Conference on Micro Electro Mechanical Systems (MEMS), Shanghai, China, 24-28 January 2016, 905–908.

CrossRef Full Text | Google Scholar

Paknahad, M., Bachhal, J. S., and Hoorfar, M. (2018). Diffusion-based humidity control membrane for microfluidic-based gas detectors. Anal. Chim. Acta 1021, 103–112. doi:10.1016/j.aca.2018.03.021

PubMed Abstract | CrossRef Full Text | Google Scholar

Paknahad, M., Ghafarinia, V., and Hoorfar, M. (2014). Refined Navier-Stokes-fourier equations for rarefied polyatomic gases. Int. Conf. Nanochannels, Microchannels, Minichannels 46278, V001T11A002. doi:10.1115/ICNMM2014-21055

CrossRef Full Text | Google Scholar

Paknahad, M., Ghafarinia, V., and Hossein-Babaei, F. (2012a). “A microfluidic gas analyzer for selective detection of biomarker gases,” in 2012 IEEE Sensors Applications Symposium, SAS 2012 - Proceedings, Brescia, Italy, 7-9 February 2012, 10–14.

CrossRef Full Text | Google Scholar

Paknahad, M., Ghafarinia, V., and Hossein-Babaei, F. (2012b). “A microfluidic gas analyzer for selective detection of biomarker gases,” in 2012 IEEE Sensors Applications Symposium Proceedings, Brescia, Italy, 7-9 February 2012, 1–5.

CrossRef Full Text | Google Scholar

Paknahad, M., Mcintosh, C., and Hoorfar, M. (2019a). Selective detection of volatile organic compounds in microfluidic gas detectors based on ‘like dissolves like. Sci. Rep. 9 (1), 161–211. doi:10.1038/s41598-018-36615-6

PubMed Abstract | CrossRef Full Text | Google Scholar

Paknahad, M., Mcintosh, C., and Hoorfar, M. (2019b). Selective detection of volatile organic compounds in microfluidic gas detectors based on ‘like dissolves like. Sci. Rep. 9 (1), 161. doi:10.1038/s41598-018-36615-6

PubMed Abstract | CrossRef Full Text | Google Scholar

Phillips, M., Herrera, J., Krishnan, S., Zain, M., Greenberg, J., and Cataneo, R. N. (1999). Variation in volatile organic compounds in the breath of normal humans. J. Chromatogr. B Biomed. Sci. Appl. 729 (1–2), 75–88. doi:10.1016/s0378-4347(99)00127-9

PubMed Abstract | CrossRef Full Text | Google Scholar

Piorek, B. D., Lee, S. J., Santiago, J. G., Moskovits, M., Banerjee, S., and Meinhart, C. D. (2007). Free-surface microfluidic control of surface-enhanced Raman spectroscopy for the optimized detection of airborne molecules. Proc. Natl. Acad. Sci. 104 (48), 18898–18901. doi:10.1073/pnas.0708596104

PubMed Abstract | CrossRef Full Text | Google Scholar

Qin, J., Zhu, B., Du, Y., and Han, Z. (2019). Terahertz detection of toxic gas using a photonic crystal fiber. Opt. Fiber Technol. 52, 101990. doi:10.1016/j.yofte.2019.101990

CrossRef Full Text | Google Scholar

Rafiefard, N., Iraji zad, A., Esfandiar, A., Sasanpour, P., Fardindoost, S., Zou, Y., et al. (2020). A graphene/TiS3 heterojunction for resistive sensing of polar vapors at room temperature. Microchim. Acta 187, 117. doi:10.1007/s00604-019-4097-y

PubMed Abstract | CrossRef Full Text | Google Scholar

Raj, A., Viswanathan, A., and Athul, T. (2015). LPG gas monitoring system. IJITR 3 (2), 1957–1960.

Google Scholar

Raj, W., Yang, D., Priest, C., Nguyen, N.-T., and Kashaninejad, N. (2021a). Rapid fabrication of superhydrophobic virtual walls for microfluidic gas extraction and sensing. Micromachines 12 (5), 514. doi:10.3390/MI12050514

PubMed Abstract | CrossRef Full Text | Google Scholar

Raj, W., Yang, D., and Priest, C. (2021b). Rapid fabrication of superhydrophobic virtual walls for microfluidic gas extraction and sensing. Micromachines (Basel) 12 (5), 514. doi:10.3390/mi12050514

PubMed Abstract | CrossRef Full Text | Google Scholar

Rebordão, G., Palma, S. I. C. J., and Roque, A. C. A. (2020a). Microfluidics in gas sensing and artificial olfaction. Sensors 20 (20), 5742. doi:10.3390/S20205742

PubMed Abstract | CrossRef Full Text | Google Scholar

Rebordão, G., Palma, S. I. C. J., and Roque, A. C. A. (2020b). Microfluidics in gas sensing and artificial olfaction. Sensors 20 (20), 5742. doi:10.3390/s20205742

PubMed Abstract | CrossRef Full Text | Google Scholar

Rezende, G. C., Le Calvé, S., Brandner, J. J., and Newport, D. (2020). Characterization of a modular microfluidic photoionization detector. Sens. Actuators B Chem. 324, 128667. doi:10.1016/j.snb.2020.128667

CrossRef Full Text | Google Scholar

Rezende, G. C., Le Calvé, S., Brandner, J. J., and Newport, D. (2019). Micro milled microfluidic photoionization detector for volatile organic compounds. Micromachines (Basel) 10 (4), 228. doi:10.3390/mi10040228

PubMed Abstract | CrossRef Full Text | Google Scholar

Riva, C., Orzi, V., Carozzi, M., Acutis, M., Boccasile, G., Lonati, S., et al. (2016). Short-term experiments in using digestate products as substitutes for mineral (N) fertilizer: Agronomic performance, odours, and ammonia emission impacts. Sci. Total Environ. 547, 206–214. doi:10.1016/j.scitotenv.2015.12.156

PubMed Abstract | CrossRef Full Text | Google Scholar

Salim, A., and Lim, S. (2018). Review of recent metamaterial microfluidic sensors. Sensors 18 (1), 232. doi:10.3390/S18010232

PubMed Abstract | CrossRef Full Text | Google Scholar

Serra, P. A. (2011). Biosensors for health, environment and biosecurity. Biosens. Health, Environ. Biosecurity. doi:10.5772/928

CrossRef Full Text | Google Scholar

Shen, C.-Y., and Liou, S.-Y. (2008). Surface acoustic wave gas monitor for ppm ammonia detection. Sens. Actuators B Chem. 131 (2), 673–679. doi:10.1016/j.snb.2007.12.061

CrossRef Full Text | Google Scholar

Shinada, K., Horiike, S., Uchiyama, S., Takechi, R., and Nishimoto, T. (2012). Development of new ionization detector for gas chromatography by applying dielectric barrier discharge. Shimadzu Hyoron 69, 255–263.

Google Scholar

Shirbeeny, W., and Mahmoud, W. E. (2014). Synthesis and characterization of transparent optical gas sensor device made of indium oxide pyramid like nanoarchitectures. Sens. Actuators B Chem. 191, 102–107. doi:10.1016/j.snb.2013.09.058

CrossRef Full Text | Google Scholar

Shooshtari, L., Rafiefard, N., Barzegar, M., Fardindoost, S., Irajizad, A., and Mohammadpour, R. (2022). Self-powered humidity sensors based on SnS2 nanosheets. ACS Appl. Nano Mat. 5 (11), 17123–17132. doi:10.1021/acsanm.2c04050

CrossRef Full Text | Google Scholar

Singh Bhati, V., Kumar, M., and Banerjee, R. (2021). Gas sensing performance of 2D nanomaterials/metal oxide nanocomposites: A review. J. Mat. Chem. C 9, 8776–8808. doi:10.1039/D1TC01857D

CrossRef Full Text | Google Scholar

Singh, S., Kumar, V., Dhanjal, D. S., Datta, S., Prasad, R., and Singh, J. (2020a). Biological biosensors for monitoring and diagnosis. Basic Res. Appl., 317–335. doi:10.1007/978-981-15-2817-0_14

CrossRef Full Text | Google Scholar

Singh, S., Kumar, V., Dhanjal, D. S., Datta, S., Prasad, R., and Singh, J. (2020b). Biological biosensors for monitoring and diagnosis. Biochimica Biophysica Acta (BBA) - Rev. Cancer, 317–335. doi:10.1007/978-981-15-2817-0_14

CrossRef Full Text | Google Scholar

Sohrabi, H., Ghasemzadeh, S., Ghoreishi, Z., Majidi, M. R., Yoon, Y., Dizge, N., et al. (2023). Metal-organic frameworks (MOF)-based sensors for detection of toxic gases: A review of current status and future prospects. Mater. Chem. Phys. 299, 127512. doi:10.1016/j.matchemphys.2023.127512

CrossRef Full Text | Google Scholar

Song, X., Hu, R., Xu, S., Liu, Z., Wang, J., Shi, Y., et al. (2021). Highly sensitive ammonia gas detection at room temperature by integratable silicon nanowire field-effect sensors. ACS Appl. Mater Interfaces 13 (12), 14377–14384. doi:10.1021/acsami.1c00585

PubMed Abstract | CrossRef Full Text | Google Scholar

Su, P., Han, Z., Kita, D., Becla, P., Lin, H., Deckoff-Jones, S., et al. (2019a). Monolithic on-chip mid-IR methane gas sensor with waveguide-integrated detector. Appl. Phys. Lett. 114 (5), 051103. doi:10.1063/1.5053599

CrossRef Full Text | Google Scholar

Su, P., Han, Z., Kita, D., Becla, P., Lin, H., Deckoff-Jones, S., et al. (2019b). Monolithic on-chip mid-IR methane gas sensor with waveguide-integrated detector. Appl. Phys. Lett. 114 (5), 51103. doi:10.1063/1.5053599

CrossRef Full Text | Google Scholar

Su, R., Lin, J.-M., Qu, F., Chen, Z., Gao, Y., and Yamada, M. (2004). Capillary electrophoresis microchip coupled with on-line chemiluminescence detection. Anal. Chim. Acta 508 (1), 11–15. doi:10.1016/j.aca.2003.11.080

CrossRef Full Text | Google Scholar

Subashini, T., Renganathan, B., Stephen, A., and Prakash, T. (2018). Acetone sensing behaviour of optical fiber clad-modified with γ-CuBr nanocrystals. Mater Sci. Semicond. Process 88, 181–185. doi:10.1016/j.mssp.2018.08.015

CrossRef Full Text | Google Scholar

Tani, H., Maehana, K., and Kamidate, T. (2004). Chip-based bioassay using bacterial sensor strains immobilized in three-dimensional microfluidic network. Anal. Chem. 76 (22), 6693–6697. doi:10.1021/ac049401d

PubMed Abstract | CrossRef Full Text | Google Scholar

Tao, J., Zhang, Q., Xiao, Y., Li, X., Yao, P., Pang, W., et al. (2016). A microfluidic-based fabry-pérot gas sensor. Micromachines (Basel) 7 (3), 36. doi:10.3390/mi7030036

PubMed Abstract | CrossRef Full Text | Google Scholar

Timmer, B. H., van Delft, K. M., Koelmans, W. W., Olthuis, W., and van den Berg, A. (2006a). Selective low concentration ammonia sensing in a microfluidic lab-on-a-chip. IEEE Sens. J. 6 (3), 829–835. doi:10.1109/JSEN.2006.874020

CrossRef Full Text | Google Scholar

Timmer, B. H., van Delft, M., Koelmans, W. W., Olthuis, W., and van den Berg, A. (2006b). Selective low concentration ammonia sensing in a microfluidic lab-on-a-chip. IEEE Sens. J. 6 (3), 829–835. doi:10.1109/jsen.2006.874020

CrossRef Full Text | Google Scholar

Tirandazi, P., and Hidrovo, C. H. (2018). An integrated gas-liquid droplet microfluidic platform for digital sampling and detection of airborne targets. Sens. Actuators B Chem. 267, 279–293. doi:10.1016/j.snb.2018.03.057

CrossRef Full Text | Google Scholar

Ueno, Y., Horiuchi, T., Niwa, O., Zhou, H., Yamada, T., and Honma, I. (2003a). Improvement of on-site microfluidic benzene, toluene, xylene (BTX) gas sensor loaded with nanostructured mesoporous silicate. Sensors Mater. 15 (8), 393–402.

Google Scholar

Ueno, Y., Horiuchi, T., Niwa, O., Zhou, H., Yamada, T., and Honma, I. (2003b). Improvement of on-site microfluidic benzene, toluene, xylene (BTX) gas sensor loaded with nanostructured mesoporous silicate. Sensors Mater. 15 (8), 393–402.

Google Scholar

Ueno, Y., Tate, A., Niwa, O., Zhou, H.-S., Yamada, T., and Honma, I. (2005a). High benzene selectivity of mesoporous silicate for BTX gas sensing microfluidic devices. Anal. Bioanal. Chem. 382 (3), 804–809. doi:10.1007/s00216-004-2974-6

PubMed Abstract | CrossRef Full Text | Google Scholar

Ueno, Y., Tate, A., Niwa, O., Zhou, H.-S., Yamada, T., and Honma, I. (2005b). High benzene selectivity of mesoporous silicate for BTX gas sensing microfluidic devices. Anal. Bioanal. Chem. 382 (3), 804–809. doi:10.1007/s00216-004-2974-6

PubMed Abstract | CrossRef Full Text | Google Scholar

U. S. E. P. A. (USEPA) (1999). National air toxics program: The integrated urban strategy. Fed. Reg. 64 (137), 38706.

Google Scholar

Vallejos, S., Gràcia, I., Bravo, J., Figueras, E., Hubálek, J., and Cané, C. (2015). Detection of volatile organic compounds using flexible gas sensing devices based on tungsten oxide nanostructures functionalized with Au and Pt nanoparticles. Talanta 139, 27–34. doi:10.1016/j.talanta.2015.02.034

PubMed Abstract | CrossRef Full Text | Google Scholar

Vashist, S. K., and Luong, J. H. T. (2018). Bioanalytical requirements and regulatory guidelines for immunoassays. Handb. Immunoass. Technol. Approaches, Performances, Appl., 81–95. doi:10.1016/B978-0-12-811762-0.00004-9

CrossRef Full Text | Google Scholar

Welch, A. (2006). Exposing the dangers of anhydrous ammonia. Nurse Pract. 31 (11), 40–45. doi:10.1097/00006205-200611000-00008

PubMed Abstract | CrossRef Full Text | Google Scholar

Wu, R., Yan, K., Zhao, J., Cai, Z., Jian, S., and Qiu, L. (2023). 2D/2D SnS2/SnSe2 van der Waals heterostructure for highly sensitive room-temperature NO2 sensor: Key role of interface contact. Chem. Eng. J. 466, 143369. doi:10.1016/j.cej.2023.143369

CrossRef Full Text | Google Scholar

Yadav, A., and Sinha, N. (2022). Nanomaterial-based gas sensors: A review on experimental and theoretical studies. Mater. Express 12 (1), 1–33. doi:10.1166/MEX.2022.2121

CrossRef Full Text | Google Scholar

Yang, K., Peretz-Soroka, H., Liu, Y., and Lin, F. (2016). Novel developments in mobile sensing based on the integration of microfluidic devices and smartphones. Lab. Chip 16 (6), 943–958. doi:10.1039/c5lc01524c

PubMed Abstract | CrossRef Full Text | Google Scholar

Yang, K., Zhu, K., Wang, Y., Qian, Z., Zhang, Y., Yang, Z., et al. (2021). Ti3C2Tx MXene-loaded 3D substrate toward on-chip multi-gas sensing with surface-enhanced Raman spectroscopy (SERS) barcode readout. ACS Nano 15 (8), 12996–13006. doi:10.1021/acsnano.1c01890

PubMed Abstract | CrossRef Full Text | Google Scholar

Yang, K., Zong, S., Zhang, Y., Qian, Z., Liu, Y., Zhu, K., et al. (2020). Array-assisted SERS microfluidic chips for highly sensitive and multiplex gas sensing. ACS Appl. Mater Interfaces 12 (1), 1395–1403. doi:10.1021/acsami.9b19358

PubMed Abstract | CrossRef Full Text | Google Scholar

Yang, Y., Mao, J., Yin, D., Zhang, T., Liu, C., Hao, W., et al. (2023). Synergy of S-vacancy and heterostructure in BiOCl/Bi2S3−x boosting room-temperature NO2 sensing. J. Hazard. Mater. 455, 131591. doi:10.1016/j.jhazmat.2023.131591”

PubMed Abstract | CrossRef Full Text | Google Scholar

Youssef, S., Podlecki, J., Habchi, R., Brouche, M., Foucaran, A., Bouvier, D., et al. (2012). Innovative prototype of a zinc-oxide based optical gas sensor. Sens. Actuators B Chem. 173, 391–395. doi:10.1016/j.snb.2012.07.025

CrossRef Full Text | Google Scholar

Yu, L., Wang, B., Cheng, M., Yang, M., Gan, S., Fan, L., et al. (2020). Association between indoor formaldehyde exposure and asthma: A systematic review and meta-analysis of observational studies. Indoor Air 30 (4), 682–690. doi:10.1111/ina.12657

PubMed Abstract | CrossRef Full Text | Google Scholar

Yunusa, Z., Hamidon, M. N., Kaiser, A., and Awang, Z. (2014). Gas sensors: A review. undefined 168 (4), 61–75. doi:10.13074/JENT.2015.12.153163

CrossRef Full Text | Google Scholar

Zhang, S., Yang, J., Alssaidy, S., Li, Z., Cheng, Y. H., Menon, N. H., et al. (2022). Microfluidic gas sensors: Detection principle and applications. Micromachines 13 (10), 1716. doi:10.3390/MI13101716

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhu, H., Nidetz, R., Zhou, M., Lee, J., Buggaveeti, S., Kurabayashi, K., et al. (2015). Flow-through microfluidic photoionization detectors for rapid and highly sensitive vapor detection. Lab. Chip 15 (14), 3021–3029. doi:10.1039/C5LC00328H

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhu, L., Meier, D., Boger, Z., Montgomery, C., Semancik, S., and DeVoe, D. L. (2007). Integrated microfluidic gas sensor for detection of volatile organic compounds in water. Sens. Actuators B Chem. 121 (2), 679–688. doi:10.1016/j.snb.2006.03.023

CrossRef Full Text | Google Scholar

Keywords: microfluidic, gas sensors, miniaturization, selectivity, sensitivity

Citation: Yeganegi A, Yazdani K, Tasnim N, Fardindoost S and Hoorfar M (2023) Microfluidic integrated gas sensors for smart analyte detection: a comprehensive review. Front. Chem. 11:1267187. doi: 10.3389/fchem.2023.1267187

Received: 26 July 2023; Accepted: 28 August 2023;
Published: 11 September 2023.

Edited by:

Juanyuan Hao, Harbin Institute of Technology, China

Reviewed by:

Lakshmi Narayanan Mosur Saravana Murthy, Intel, United States
Ruozhen Wu, Wuyi University, China

Copyright © 2023 Yeganegi, Yazdani, Tasnim, Fardindoost and Hoorfar. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Mina Hoorfar, bWhvb3JmYXJAdXZpYy5jYQ==

These authors have contributed equally to this work

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.