ORIGINAL RESEARCH article

Front. Chem., 31 August 2023
Sec. Analytical Chemistry
This article is part of the Research Topic Analytical Chemistry Editor's Pick 2024 View all 18 articles

Noninvasive drug adherence monitoring of antipsychotic patients via finger sweat testing

  • 1School of Chemistry and Chemical Engineering, University of Surrey, Guildford, United Kingdom
  • 2Surrey Ion Beam Centre, University of Surrey, Guildford, United Kingdom
  • 3Abraham Cowley Unit, St Peter’s Hospital, Surrey and Borders Partnership NHS Foundation Trust, Chertsey, United Kingdom
  • 4Faculty of Health and Medical Sciences, University of Surrey, Guildford, United Kingdom

Collection of finger sweat is explored here as a rapid and convenient way of monitoring patient adherence to antipsychotic drugs. Finger sweat samples (n = 426) collected from patients receiving treatment with clozapine, quetiapine and olanzapine were analysed by liquid chromatography mass spectrometry, including a subgroup of patients with paired plasma samples. Finger sweat samples were also analysed from a negative control group and patients who had handled antipsychotic medication only. The finger sweat test (based on the detection of parent drug in one donated sample) was 100% effective in monitoring adherence within commonly prescribed dosing ranges. In comparison to participants who handled the medication only, the test could distinguish between contact and administration through monitoring of the drug metabolite, or the level of parent drug. Additionally, in a subgroup of patients prescribed clozapine, a statistically significant correlation was observed between the mass of parent drug in finger sweat and plasma concentration. The finger sweat technology shows promise as a dignified, noninvasive method to monitor treatment adherence in patients taking antipsychotics.

1 Introduction

One of the greatest challenges in the treatment of psychotic disorders is nonadherence to antipsychotic medication, where approximately half of patients do not adhere to their prescribed regime (García et al., 2016). Poor compliance is consistently associated with a high rate of relapse and unfortunate patient outcomes, including increased risk of rehospitalization and suicide (Higashi et al., 2013). Such consequences extend beyond patient welfare, where greater use of emergency services, longer hospital stays and societal effects from violent or criminal behavior incur increased costs to society and healthcare systems.

Atypical antipsychotics such as clozapine (CLZ), quetiapine (QTP) and olanzapine (OLZ) are commonly prescribed for the treatment of schizophrenia and other psychotic and affective disorders. Reportedly more effective than their predecessors, particularly in respect to the negative or depressive symptoms of psychosis, these second-generation medications are less likely to produce extrapyramidal side effects (Gründer et al., 2009). Whilst better tolerated, several adverse effects, most notably metabolic disruption (Pillinger et al., 2020) are associated with these medications, especially at higher dosages (Haddad and Sharma, 2012). Despite the associated risks, antipsychotic medications are considered the primary tool for the alleviation and management of psychotic symptoms.

Various objective (observed administration, electronic pill dispensers and drug measurements) and subjective (self-reporting, clinicians’ opinion) methods have been used to monitor antipsychotic adherence (Velligan et al., 2006; Haddad et al., 2014). Objective methods are considered to provide more accurate measurements than subjective methods. Measurement of antipsychotic drugs and metabolites in biofluids can inform dose adjustment and reduce the risk of adverse effects or toxicity (Skogh et al., 2002; Qi and Liu, 2021), as well as provide information relating to adherence. Traditionally such measurements are performed using serum or plasma (Aravagiri and Marder, 2001; Zhou et al., 2004; Cao et al., 2020; Qi and Liu, 2021). However, analytical methods have been developed for the evaluation of antipsychotics in hair (Weinmann et al., 2002; Günther et al., 2018; 2020), oral (Fisher et al., 2013), and cerebrospinal fluid (Josefsson et al., 2010).

Fingerprints, or finger sweat, offer a noninvasive alternative for drug monitoring. Sample collection is quick, convenient and does not require any specialist materials or training. Storage and transportation of sweat samples is much simpler than more traditional matrices as the samples are not biohazardous. The detection of drugs and their metabolites in fingerprint sweat has been reported previously for both illicit (Jacob et al., 2008; Bailey et al., 2015; Costa et al., 2017; Hudson et al., 2018; Ismail et al., 2018; Czerwinska et al., 2020; Jang et al., 2020) and therapeutic drugs (Goucher et al., 2009; Costa et al., 2021; Ismail et al., 2022). Finger sweat from unwashed hands comprises eccrine sweat, as well as substances handled by a participant. In contrast, finger sweat samples provided after handwashing are understood to be more reflective of eccrine sweat (Jang et al., 2020).

Our previous work (Costa et al., 2021) has shown that QTP was detected in the fingerprints of two patients, but to our knowledge, the presence of other antipsychotic drugs in finger sweat, and the significance of detecting them, has never been reported. Here we seek to explore the prevalence of antipsychotic medication in finger sweat and assess the significance of a ‘Positive’ result for the first time.

In this work, we describe a method for the determination of CLZ, QTP and OLZ in finger sweat by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). We assess the ability of the method to detect the parent drug and metabolite in finger sweat with respect to administered dose. To test whether a patient can falsify the test, we compare these results to participants who have handled the drug only, along with a negative control group. Finally, to assess the quantitative potential of the finger sweat test, we explore the relationship between CLZ and its metabolite, N-desmethylclozapine (NDMC) in finger sweat and paired plasma samples.

2 Methods

2.1 Sample collection

Favorable ethical opinion was obtained from the National Research Ethics Service (NRES-REC reference 18/NE/0071) for the collection of finger sweat and plasma samples from patients at Surrey and Borders Partnership NHS Trust and Sussex Partnership NHS Foundation Trust. Prior to sampling, all patients provided written informed consent for collection and subsequent analysis for drug level determination. Informed consent for study participation included provision for the collection of basic metadata parameters (including treatment regime and time of last dose–see Supplementary Table S1) alongside biological sampling.

The study primarily focused on collection of finger sweat samples from patients receiving treatment with either CLZ (n = 33 patients; 198 samples), QTP (n = 7 patients; 42 samples) or OLZ (n = 20 patients; 120 samples). An additional sub study was performed where patients (n = 11) receiving CLZ also provided paired (time-matched) plasma for comparison to finger sweat. For patients receiving CLZ and QTP, oral administration was prescribed in the range 25—550 and 100—500 mg/day, respectively. For OLZ, the prescribed treatment regime was a combination of oral administration in the range 2.5—20 mg/day and monthly injection in the range 300—420 mg. Information relating to dose and time of last administration included within this study was self-reported by patients. We have therefore assumed truthful reporting and adherence to prescribed medication.

Additional finger sweat samples were collected from a drug naive negative control group (n = 30) as well as participants whose only association with an assigned antipsychotic drug was through touch. To mimic events which may lead to a false positive result, either accidental or intentional, these “contact only” participants (n = 6) were asked to handle antipsychotic medication. The participants were asked to handle whole tablets with their right hand and to touch crushed tablets with the left hand before donating samples from both hands.

2.1.1 Finger sweat collection

Finger sweat collection devices were prepared by mounting a paper substrate (Whatman 1-Chr-grade) atop a glass microscopy slide.

Finger sweat samples were collected from patients receiving antipsychotic medication before and after a hand washing procedure, hereby described as “as presented” and “after washing” respectively. Unless otherwise specified, finger sweat samples were collected from the index, middle and ring fingers of the right hand. After hand washing with soap and tap water to remove external contamination, patients were required to wear nitrile gloves for a period of 10 min to induce sweating before collection of after washing samples (Figure 1).

FIGURE 1
www.frontiersin.org

FIGURE 1. Sample collection procedure. Finger sweat samples collected (1) “as presented” and (2) “after washing”. Created using Biorender.com.

Finger sweat samples from a drug naive control group (n = 30) were collected from the right index finger only. Collection of samples within drug contact study were collected from both hands after handling of medication. To avoid contact between the two hands, the fingertips were washed separately by a gloved third party.

All samples were collected onto the porous paper substrate using controlled deposition time and pressure, 30 s at a pressure of 800–1,200 g (measured using a generic kitchen scale). Samples were transported at ambient temperature in microscope storage boxes before transfer to—80°C for long-term storage until analysis.

2.1.2 Plasma sample collection

Paired plasma samples were also collected from subgroup of patients (n = 11) receiving treatment with CLZ. Venous blood samples were collected into 3 mL heparinized vials. All samples were centrifuged at 4°C for 10 min (1725 ×g) and the resultant plasma was stored at—80 °C until analysis.

2.2 Chemicals and reagents

Certified reference materials of antipsychotic drugs (CLZ, QTP, OLZ) their respective metabolites (NDMC, norquetiapine (NQTP), N-desmethylolanzapine (DMO)) and deuterated internal standards (IS) (CLZ-d4, QTP-d8, OLZ-d8) were obtained from Sigma Aldrich. Optima™ LC/MS grade acetonitrile (ACN), formic acid (FA), methanol and water were obtained from Fisher Scientific.

2.3 Standard curve samples

2.3.1 Finger sweat methodology

A typical standard curve consisted of six standard levels prepared in water and spiked in fixed volume (10 µL) onto chromatography paper (Whatman 1-Chr-grade, 2 × 2 cm) as well as blank papers. Each level was freshly prepared in triplicate before drying at ambient temperature for 1 hour prior to extraction from paper as described in section 2.4.1. Based on proof-of-concept data, standard curve and quality control (QC) samples were prepared using this procedure but at different concentrations depending on analyte. Standards ranged from 60—360 pg for CLZ/NDMC, 30—180 pg for QTP/NQTP and 100—600 pg for OLZ/DMO. Internal standards (IS) were 200 pg, 100 pg and 350 pg, respectively. For assessment of method performance, three QC levels were prepared on paper for each analyte, reflective of lower, middle and upper of the working range. These were 90, 200 and 330 pg for CLZ/NDMC; 40, 100 and 160 pg for QTP/NQTP; and 150, 350 and 550 pg for OLZ/DMO.

For patients with matched plasma samples, the working range was extended to 100—600 pg (IS = 350 pg) for CLZ and NDMC. Three QC levels (150, 350 and 550 pg) were selected to assess the performance of the extended range.

2.3.2 Plasma methodology

For measurement of CLZ and NDMC only, standard curve samples were prepared by spiking pooled plasma in the range of 25—1,500 ng/mL. Three QC levels (75, 500 and 1,200 ng/mL) were prepared in pooled plasma for verification of method performance. An IS solution (100 ng/mL CLZ-d4) was prepared in methanol.

2.4 Sample preparation

2.4.1 Finger sweat samples

Prior to extraction, samples prepared on paper (i.e., standard curve or QC samples) or collected onto paper (i.e., finger sweat from patients or drug naïve controls) were spiked with an IS solution (exact mass of IS described in Section 2.3.1) and allowed to dry at ambient temperature for 1 hour. Using sterile tweezers, the papers were transferred into 2 mL centrifuge tubes with 1.5 mL of methanol. The tubes were then centrifuged at 9,500 ×g for 2 min. The paper substrate was discarded using sterilized tweezers, and the resultant solvent extract was evaporated to dryness using nitrogen. Samples were reconstituted in 100 µL 50:50 mobile phase A (10 mM ammonium acetate adjusted to pH 4.6 using FA) and mobile phase B (ACN +0.1% FA (v/v)) for analysis.

2.4.2 Plasma samples

All standard, QC and patient plasma samples were prepared using an existing extraction procedure (Qi and Liu, 2021). 50 μL aliquots of plasma were defrosted and prepared by protein precipitation with ACN. To each sample, 150 µL of ACN and 20 µL of IS solution were added and vortexed for 5 min. The mixtures were subjected to refrigerated (4°C) centrifugation at 15,000 rpm for 8 min 40 μL of the resultant supernatant was removed and immersed in 200 µL of water, vortexed for a further minute and transferred into vials for analysis.

2.5 Instrumentation and sample analysis

Chromatographic separation was performed using a Thermo Scientific™ Ultimate 3,000 ultra-high-performance liquid chromatography (UHPLC) system equipped with a Kinetex XB-C18 column (100 × 2.1 mm, 5 μm, Phenomenex). The 3-min gradient separation was operated at 30°C with a flow rate of 0.25 mL/min. The starting mobile phase comprised 95% A and 5% B which linearly increased to 80% B at 2 min, held constant for 0.5 min, before returning to the initial composition.

The UHPLC system was coupled to a Thermo Scientific Q Exactive™ Plus Hybrid Quadrupole-Orbitrap™ Mass Spectrometer (MS). The MS was used to scan for all analytes using high resolution full scan (HRFS). MS/MS analysis was performed using data dependent acquisition mode (dd-MS2). The operating conditions of both the HRFS and dd-MS2 are defined in Supplementary Table S2.

Data acquisition and processing was completed using Thermo Scientific TraceFinder™ software (version 5.0). Statistical analysis was performed using IBM SPSS Statistics software (version 28.0).

2.6 Method performance

Method performance was evaluated using the Food and Drug Administration guidelines to determine selectivity, linearity, intra- and inter-day accuracy and precision, limit of detection (LOD) and lower limit of quantification (LLOQ), matrix effect and recovery (finger sweat only), carryover and stability (U.S. Department of Health and Human Services and Food and Drug Administration, 2018). Full details of method performance are provided within the Supplementary Material.

In brief, a linear response was obtained for all drugs and metabolites with R2 values of >0.973 when extracted from paper (Supplementary Table S3). Using the initially selected working ranges for qualitative assessment of antipsychotics in finger sweat only, the method was repeatable for analytes extracted on the same day (intra-day relative standard deviation (RSD) < 20%) (Supplementary Table S4). However, for OLZ/DMO, the method showed poor reproducibility when comparing QC samples extracted from paper on non-consecutive days. Therefore, clinical finger sweat samples were run in batches determined by drug type with standard curves extracted on each day of analysis.

Method performance experiments were repeated to assess the performance of the finger sweat method at the higher working range selected for the subset of patients with paired finger sweat and plasma samples. The intra- and inter-day accuracy and precision of CLZ/NDMC extracted from paper and in plasma was assessed using relative error (RE) and RSD. The three QC levels indicated acceptable accuracy and precision (RE and RSD <15%) for both biological matrices (Supplementary Tables S5, S6).

3 Results

Chromatograms of drug and metabolite standards are displayed in Supplementary Figure S1. No significant interference with the antipsychotic drugs and metabolites were observed within the paper only blanks. Proof of concept through successful detection and confirmation by dd-MS2 was achieved for each of the parent drugs and their metabolites within human samples (see Supplementary Figure S2). All antipsychotics were below the LOD for samples collected from the negative control group (see Supplementary Figure S3).

3.1 Detection of antipsychotics in finger sweat

The detection rate of the parent drug and metabolite in all finger sweat samples versus per participant is summarized in Table 1. Samples and/or patients are classified as “positive” where the analyte is detected.

TABLE 1
www.frontiersin.org

TABLE 1. Detection of antipsychotic drugs and metabolites in finger sweat only participants, collected “as presented” and “after washing”, defined in all samples and per participant.

3.1.1 Clozapine

CLZ performed most reliably of the three antipsychotics. In patients prescribed 100 mg/day or higher, detection rate of the parent drug was 100% in samples collected both as presented and after washing. Across all participants, successful detection of CLZ correlated with daily dose, where only one sample was CLZ negative. This sample was collected after washing from participant AP-109, prescribed the lowest dose of 25 mg/day. These results indicate that the fingerprint test has sufficient sensitivity for medical application, for example, in the treatment of schizophrenia, where a low dose of clozapine is 150—300 mg/day (Subramanian et al., 2017). Using presence of parent drug in at least one finger after washing as indication of drug administration, the finger sweat test was 100% effective in monitoring CLZ adherence in all patients, including those prescribed below the typical dose range.

Presence of NDMC within patient samples was less prevalent and did not correlate with prescribed dose. Although not detected in any samples from AP-109, other patients also did not exhibit the metabolite in any samples after washing, namely, AP-127 and AP-118, prescribed 140 and 500 mg/day. It is possible that these results are related to quality of sample, as previous studies in finger sweat have shown that poor deposition of sample can generate false negative results (Ismail et al., 2022). Using presence of the metabolite in at least one finger as indication of adherence in patients prescribed 100 mg/day or higher, the test was 94% effective using samples as presented or 88% effective after washing.

3.1.2 Quetiapine

Both QTP and NQTP were detected in all samples collected as presented and after washing. Therefore, the test was 100% effective in monitoring QTP adherence. Although only a small number of patients were recruited, these results suggest the test is sufficiently sensitive to monitor typical doses prescribed in the treatment of bipolar disorder and schizophrenia which range 400—800 mg/day by oral administration (Muneer, 2015) compared to 100—500 mg/day prescribed to patients included in this study.

3.1.3 Olanzapine

OLZ and its metabolite performed most inconsistently of the three groups. Whilst OLZ was detected in 75% of samples after washing, DMO was rarely detected and only observed in as presented samples. This is likely due to the higher LOD (100 pg) and low doses of drug in comparison to others within this study. Inspection of the data per participant showed that 100% (n = 20) could be classified as ‘Positive’ based on detection of OLZ in at least one finger as presented or 80% after washing. Detection of OLZ was found to be more consistent in patients who were administered medication by monthly injection, with 100% detection of OLZ in all fingers both before and after washing.

3.2 Drug contact versus administration

To explore the possibility of using the test to monitor adherence to antipsychotic medication, we assessed the feasibility of using the test to distinguish between contact and ingestion of a given drug. It is possible that false positive results could arise from both innocent handling of a tablet, as well as a deliberate attempt to cheat the test. Therefore, finger sweat samples were collected from volunteers who were asked to handle whole tablets with their right hand to mimic administration and to rub the powder crushed tablets across the tips of the left fingers to simulate intentional doctoring of a result.

For CLZ and QTP, contact-only participants were distinguished from drug users by lower levels or lack of metabolite within their sweat samples. Through plotting the ratio of metabolite to parent drug, a visually and statistically significant (p < 0.001, 2-tailed Mann Whitney U-test) distinction between the two populations was observed both before and after hand washing (Figures 2, 3).

FIGURE 2
www.frontiersin.org

FIGURE 2. Ratio of metabolite/parent drug in finger sweat samples collected (A) “as presented” and (B) “after washing” for clozapine users prescribed ≥100 mg/day (n = 32 participants, labelled “drug user”) and volunteers (N = 2) which held antipsychotic tablet in right hand (labelled “tablet”) and rubbed crushed tablet in left hand (labelled “powder”).

FIGURE 3
www.frontiersin.org

FIGURE 3. Ratio of metabolite/parent drug in finger sweat samples collected (A) “as presented” and (B) “after washing” for quetiapine users (n = 7 participants, labelled “drug user”) and volunteers (N = 2) which held antipsychotic tablet in right hand (labelled “tablet”) and rubbed crushed tablet in left hand (labelled “powder”).

As DMO was rarely detected in either the drug user or the contact only samples, it was not possible to adopt the same approach as for CLZ and QTP. Comparison of the mass of parent drug showed a statistically significant (p < 0.001, 2-tailed Mann Whitney U-test) difference between the two populations for OLZ (see Supplementary Figure S4). This result was repeatable for CLZ and QTP also, suggesting that high levels of parent drug could indicate a false positive result originating from contact with medication.

3.3 Comparison of plasma and finger sweat

Paired plasma and finger sweat samples were collected from a subgroup of patients prescribed CLZ. Daily dose was matched to the previous analysis, ranging 25—550 mg/day. Given that many of the first batch of samples exhibited analyte levels above the calibration range, the linear range was extended to provide quantitative measurements of drug and metabolite in finger sweat.

Finger sweat was found to be 100% effective in monitoring adherence, where both CLZ and NDMC were detected in at least one finger either as presented and after washing. Only one participant (PS-005) provided any negative finger sweat samples. In this case, the parent drug was detected in two fingers as presented and a single finger after washing, whereas NDMC was detected in the index finger as presented only. This could be due to several factors: including the sub-therapeutic dose of CLZ (25 mg/day), the short duration of treatment (approximately 1 week) and poor deposition of sample. It should also be noted that this patient was difficult to bleed, suggestive of dehydration, resulting in insufficient whole blood for plasma separation. In such cases, where an indication of patient adherence is required but collection of blood has failed, finger sweat provides a simplistic opportunity to assess adherence in the absence of sufficient plasma for drug analysis.

A comparison of CLZ and NDMC in after washing samples versus concentration in plasma is displayed in Figure 4. The ratio of metabolite to parent drug in sweat was 0.42 ± 0.19 compared to 0.65 ± 0.22 in plasma. Visually, the mass of analyte in finger sweat was found to mirror the concentration in plasma. The correlation of average mass per finger versus plasma concentration yields a Pearson correlation coefficient (r) of 0.56 (p < 0.04, 1-tailed) and 0.45 (p < 0.09, 1-tailed) for CLZ and NDMC. Inspection of CLZ correlation per finger showed that the middle and ring finger correlated most strongly, with Pearson’s r values of 0.62 (p < 0.02, 1-tailed) and 0.75 (p < 0.01, 1-tailed) (Figure 5). This suggests that sampling of middle and ring fingers is preferable for best representation of plasma level.

FIGURE 4
www.frontiersin.org

FIGURE 4. Comparison of mass in finger sweat collected “after washing” versus plasma concentration for (A) clozapine and (B) N-desmethylclozapine.

FIGURE 5
www.frontiersin.org

FIGURE 5. Pearson correlation coefficient (r) and p-value (P) (1-tailed) for the mass of clozapine in finger sweat collected “after washing” from the middle and ring fingers and clozapine concentration in paired plasma samples.

4 Discussion

Antipsychotic medication is considered to be the main course of treatment of psychotic disorders. Despite the extreme consequences associated with nonadherence and consequent relapse, patient adherence is often assessed by subjective means (Velligan et al., 2006). The introduction of a simple and dignified method of monitoring patients could improve patient experience and outcomes. Collection of finger sweat is quick, convenient and does not require any specialist training or equipment. Targeted analysis of finger sweat samples offers a more accurate alternative to subjective adherence monitoring methods without the invasive procedures required for blood collection. With further development, finger sweat based diagnostics has the potential to inform clinicians on dose efficacy and toxicity.

In this work, three common antipsychotic drugs (CLZ, QTP, OLZ) and their metabolites were successfully detected in finger sweat using LC-MS/MS. Our results demonstrate that a test based on the detection of the parent drug in at least 1 of 3 samples collected as presented was 100% effective in monitoring patient adherence. Using participants who had handled antipsychotic medication only, we were able to distinguish between contact and administration of a given drug where potential false positive results were characterized either by a lack of metabolite, or by exceedingly high levels of parent drug. Similarly, no interferences were found in the negative control group. A limitation of the finger sweat sampling method used within this study was additional time required for handwashing and collection of after washing samples. These results suggest that for qualitative assessment of adherence using finger sweat, the addition of the hand washing step is not necessary. This would simplify the test for use by a layperson, as well as further speed the collection process.

To our knowledge, this is also the first study describing the relationship of CLZ and its metabolite in finger sweat and plasma. Although inter-finger levels varied, the test was sufficiently sensitive to detect the typical dosing range of CLZ prescribed in the treatment of psychotic disorders such as schizophrenia. The middle and ring fingers were found to reflect the plasma concentrations most strongly, where a statistically significant correlation between CLZ plasma concentration and mass per finger after washing was observed. These data provide a foundation for further exploration of the relationship between the two biological matrices. Opportunities include the implementation of a standardization procedure, such as that described by (Goucher et al., 2009) whereby creatinine was used to smooth the elimination profile of lorazepam in ten overlayed fingerprints from the same donor or by (Ismail et al., 2022) who employed taurine to reduce the coefficient of variation of acetyl isoniazid (the main metabolite of a key anti-tuberculosis drug) between multiple fingerprint samples collected simultaneously from the same donor. Identification and implementation of similar small molecule metabolites within the antipsychotic finger sweat workflow could account for intra-donor variability and allow for more reliable quantitative measurements in future analyses.

In conclusion, a sensitive, convenient, and non-invasive method for monitoring adherence in antipsychotic patients has been developed. Analysis of human finger sweat samples from drug users has shown the method to be 100% effective at detecting commonly prescribed doses of antipsychotic medication, given the test criteria (detection of parent drug in 1 of 3 samples). Using these criteria, the test can distinguish drug administration from drug contact, and non-drug users. The finger sweat technology has broader opportunities in clinical environment, in quantitative monitoring antipsychotic medication or monitoring adherence to other treatment regimes.

Data availability statement

The raw data supporting the conclusion of this article will be made available by the authors, without undue reservation.

Ethics statement

The studies involving humans were approved by Health Research Authority’s National Research Ethics Service. The studies were conducted in accordance with the local legislation and institutional requirements. The participants provided their written informed consent to participate in this study.

Author contributions

KL, CF, CC, RN, and MB contributed to conceptualization of this study. KL and CF performed methodology development and validation experiments. KL was responsible for management of clinical study and, with HL and CF, completed the analysis of collected samples. MB was responsible for group supervision and funding acquisition. KL processed the raw data and wrote the original draft of the manuscript. All authors contributed to the article and approved the submitted version.

Funding

The authors would like to acknowledge funding from the EPSRC (EP/P001440/1 and EP/R031118/1), NIHR Clinical Research Network (CPMS ID: 37634) and Intelligent Fingerprinting Limited. The authors declare that this study received funding from Intelligent Fingerprinting Limited for the PhD studentship of CF. The funder was not involved in the study design, collection, analysis, interpretation of data, the writing of this article, or the decision to submit it for publication.

Acknowledgments

The authors would like to thank Joshua Cudworth and the staff at Surrey and Borders NHS Partnership Trust, as well as Evelin Vogel and the staff at Sussex Partnership NHS Foundation Trust, for assistance in collection of the samples used within this study.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fchem.2023.1245089/full#supplementary-material

References

Aravagiri, M., and Marder, S. R. (2001). Simultaneous determination of clozapine and its N-desmethyl and N-oxide metabolites in plasma by liquid chromatography/electrospray tandem mass spectrometry and its application to plasma level monitoring in schizophrenic patients. J. Pharm. Biomed. Anal. 26, 301–311. doi:10.1016/S0731-7085(0100410-1)

PubMed Abstract | CrossRef Full Text | Google Scholar

Bailey, M. J., Bradshaw, R., Francese, S., Salter, T. L., Costa, C., Ismail, M., et al. (2015). Rapid detection of cocaine, benzoylecgonine and methylecgonine in fingerprints using surface mass spectrometry. Analyst 140, 6254–6259. doi:10.1039/c5an00112a

PubMed Abstract | CrossRef Full Text | Google Scholar

Cao, Y., Zhao, F., Chen, J., Huang, T., Zeng, J., Wang, L., et al. (2020). A simple and rapid LC-MS/MS method for the simultaneous determination of eight antipsychotics in human serum, and its application to therapeutic drug monitoring. J. Chromatogr. B Anal. Technol. Biomed. Life Sci. 1147, 122129. doi:10.1016/j.jchromb.2020.122129

PubMed Abstract | CrossRef Full Text | Google Scholar

Costa, C., Frampas, C., Longman, K. A., Palitsin, V., Ismail, M., Sears, P., et al. (2021). Paper spray screening and liquid chromatography/mass spectrometry confirmation for medication adherence testing: a two-step process. Rapid Commun. Mass Spectrom. 35, e8553. doi:10.1002/rcm.8553

CrossRef Full Text | Google Scholar

Costa, C., Webb, R., Palitsin, V., Ismail, M., De Puit, M., Atkinson, S., et al. (2017). Rapid, secure drug testing using fingerprint development and paper spray mass spectrometry. Clin. Chem., 63 (11):1745–1752. doi:10.1373/clinchem.2017.275578

PubMed Abstract | CrossRef Full Text | Google Scholar

Czerwinska, J., Jang, M., Costa, C., Parkin, M. C., George, C., Kicman, A. T., et al. (2020). Detection of mephedrone and its metabolites in fingerprints from a controlled human administration study by liquid chromatography-tandem mass spectrometry and paper spray-mass spectrometry. Analyst 145, 3038–3048. doi:10.1039/C9AN02477H

PubMed Abstract | CrossRef Full Text | Google Scholar

Fisher, D. S., Partridge, S. J., Handley, S. A., Couchman, L., Morgan, P. E., and Flanagan, R. J. (2013). LC–MS/MS of some atypical antipsychotics in human plasma, serum, oral fluid and haemolysed whole blood. Forensic Sci. Int. 229, 145–150. doi:10.1016/J.FORSCIINT.2013.02.010

PubMed Abstract | CrossRef Full Text | Google Scholar

García, S., Martínez-Cengotitabengoa, M., López-Zurbano, S., Zorrilla, I., López, P., Vieta, E., et al. (2016). Adherence to antipsychotic medication in bipolar disorder and schizophrenic patients: a systematic review. J. Clin. Psychopharmacol. 36, 355–371. doi:10.1097/JCP.0000000000000523

PubMed Abstract | CrossRef Full Text | Google Scholar

Goucher, E., Kicman, A., Smith, N., and Jickells, S. (2009). The detection and quantification of lorazepam and its 3-O-glucuronide in fingerprint deposits by LC-MS/MS. J. Sep. Sci. 32, 2266–2272. doi:10.1002/jssc.200900097

PubMed Abstract | CrossRef Full Text | Google Scholar

Gründer, G., Hippius, H., and Carlsson, A. (2009). The “atypicality” of antipsychotics: a concept re-examined and re-defined. Nat. Rev. Drug Discov. 8:3, 197–202. doi:10.1038/nrd2806

PubMed Abstract | CrossRef Full Text | Google Scholar

Günther, K. N., Banner, J., Linnet, K., and Johansen, S. S. (2020). Segmental hair analysis of olanzapine and N-desmethyl-olanzapine in postmortem hair from mentally ill patients by LC-MS/MS. J. Pharm. Biomed. Anal. 190, 113510. doi:10.1016/J.JPBA.2020.113510

PubMed Abstract | CrossRef Full Text | Google Scholar

Günther, K. N., Johansen, S. S., Nielsen, M. K. K., Wicktor, P., Banner, J., and Linnet, K. (2018). Post-mortem quetiapine concentrations in hair segments of psychiatric patients - correlation between hair concentration, dose and concentration in blood. Forensic Sci. Int. 285, 58–64. doi:10.1016/J.FORSCIINT.2018.01.020

PubMed Abstract | CrossRef Full Text | Google Scholar

Haddad, P. M., Brain, C., and Scott, J. (2014). Nonadherence with antipsychotic medication in schizophrenia: challenges and management strategies. Patient Relat. Outcome Meas. 5, 43–62. doi:10.2147/PROM.S42735

PubMed Abstract | CrossRef Full Text | Google Scholar

Haddad, P. M., and Sharma, S. G. (2012). Adverse effects of atypical antipsychotics. CNS Drugs 21 (11), 911–936. doi:10.2165/00023210-200721110-00004

PubMed Abstract | CrossRef Full Text | Google Scholar

Higashi, K., Medic, G., Littlewood, K. J., Diez, T., Granström, O., and De Hert, M. (2013). Medication adherence in schizophrenia: factors influencing adherence and consequences of nonadherence, a systematic literature review. Ther. Adv. Psychopharmacol. 3, 200–218. doi:10.1177/2045125312474019

PubMed Abstract | CrossRef Full Text | Google Scholar

Hudson, M., Stuchinskaya, T., Ramma, S., Patel, J., Sievers, C., Goetz, S., et al. (2018). Drug screening using the sweat of a fingerprint: lateral flow detection of d9-tetrahydrocannabinol, cocaine, opiates and amphetamine. J. Anal. Toxicol. 43, 88–95. doi:10.1093/jat/bky068

PubMed Abstract | CrossRef Full Text | Google Scholar

Ismail, M., Costa, C., Longman, K., Chambers, M. A., Menzies, S., and Bailey, M. J. (2022). Potential to use fingerprints for monitoring therapeutic levels of isoniazid and treatment adherence. ACS Omega 7, 15167–15173. doi:10.1021/acsomega.2c01257

PubMed Abstract | CrossRef Full Text | Google Scholar

Ismail, M., Stevenson, D., Costa, C., Webb, R., De Puit, M., and Bailey, M. (2018). Noninvasive detection of cocaine and heroin use with single fingerprints: Determination of an environmental cutoff. doi:10.1373/clinchem.2017.281469

CrossRef Full Text | Google Scholar

Jacob, S., Jickells, S., Wolff, K., and Smith, N. (2008). Drug testing by chemical analysis of fingerprint deposits from methadone- maintained opioid dependent patients using UPLC-MS/MS. Drug Metab. Lett. 2, 245–247. doi:10.2174/187231208786734094

PubMed Abstract | CrossRef Full Text | Google Scholar

Jang, M., Costa, C., Bunch, J., Gibson, B., Ismail, M., Palitsin, V., et al. (2020). On the relevance of cocaine detection in a fingerprint. Sci. Rep. 10, 1974. doi:10.1038/s41598-020-58856-0

PubMed Abstract | CrossRef Full Text | Google Scholar

Josefsson, M., Roman, M., Skogh, E., and Dahl, M. L. (2010). Liquid chromatography/tandem mass spectrometry method for determination of olanzapine and N-desmethylolanzapine in human serum and cerebrospinal fluid. J. Pharm. Biomed. Anal. 53, 576–582. doi:10.1016/J.JPBA.2010.03.040

PubMed Abstract | CrossRef Full Text | Google Scholar

Muneer, A. (2015). Pharmacotherapy of bipolar disorder with quetiapine: a recent literature review and an update. Clin. Psychopharmacol. Neurosci. 13, 25–35. doi:10.9758/CPN.2015.13.1.25

PubMed Abstract | CrossRef Full Text | Google Scholar

Pillinger, T., McCutcheon, R. A., Vano, L., Mizuno, Y., Arumuham, A., Hindley, G., et al. (2020). Comparative effects of 18 antipsychotics on metabolic function in patients with schizophrenia, predictors of metabolic dysregulation, and association with psychopathology: a systematic review and network meta-analysis. Lancet Psychiatry 7, 64–77. doi:10.1016/S2215-0366(19)30416-X

PubMed Abstract | CrossRef Full Text | Google Scholar

Qi, Y., and Liu, G. (2021). Ultra-performance liquid chromatography-tandem mass spectrometry for simultaneous determination of antipsychotic drugs in human plasma and its application in therapeutic drug monitoring. Drug Des. Devel Ther. 15, 463–479. doi:10.2147/DDDT.S290963

PubMed Abstract | CrossRef Full Text | Google Scholar

Skogh, E., Reis, M., Dahl, M. L., Lundmark, J., and Bengtsson, F. (2002). Therapeutic drug monitoring data on olanzapine and its N-demethyl metabolite in the naturalistic clinical setting. Ther. Drug Monit. 24, 518–526. doi:10.1097/00007691-200208000-00010

PubMed Abstract | CrossRef Full Text | Google Scholar

Subramanian, S., Völlm, B. A., and Huband, N. (2017). Clozapine dose for schizophrenia. Cochrane Database Syst. Rev. 2017. doi:10.1002/14651858.CD009555.PUB2

PubMed Abstract | CrossRef Full Text | Google Scholar

U.S. Department of Health and Human Services, and Food and Drug Administration (2018). Bioanalytical method validation guidance for industry. Available at: http://www.fda.gov/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/default.htmand/orhttp://www.fda.gov/AnimalVeterinary/GuidanceComplianceEnforcement/GuidanceforIndustry/default.htm (Accessed January 18, 2023).

Google Scholar

Velligan, D. I., Lam, Y. W. F., Glahn, D. C., Barrett, J. A., Maples, N. J., Ereshefsky, L., et al. (2006). Defining and assessing adherence to oral antipsychotics: a review of the literature. Schizophr. Bull. 32, 724–742. doi:10.1093/SCHBUL/SBJ075

PubMed Abstract | CrossRef Full Text | Google Scholar

Weinmann, W., Müller, C., Vogt, S., and Frei, A. (2002). LC-MS-MS analysis of the neuroleptics clozapine, flupentixol, haloperidol, penfluridol, thioridazine, and zuclopenthixol in hair obtained from psychiatric patients. J. Anal. Toxicol. 26, 303–307. doi:10.1093/JAT/26.5.303

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhou, Z., Li, X., Li, K., Xie, Z., Cheng, Z., Peng, W., et al. (2004). Simultaneous determination of clozapine, olanzapine, risperidone and quetiapine in plasma by high-performance liquid chromatography–electrospray ionization mass spectrometry. J. Chromatogr. B 802, 257–262. doi:10.1016/J.JCHROMB.2003.11.037

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: finger sweat, noninvasive, antipsychotic, adherence, liquid chromatography mass spectrometry

Citation: Longman K, Frampas C, Lewis H, Costa C, Nilforooshan R, Chambers M and Bailey M (2023) Noninvasive drug adherence monitoring of antipsychotic patients via finger sweat testing. Front. Chem. 11:1245089. doi: 10.3389/fchem.2023.1245089

Received: 23 June 2023; Accepted: 02 August 2023;
Published: 31 August 2023.

Edited by:

Maria Del Mar Ramirez Fernandez, Institut National de Criminalistique et de Criminologie, Belgium

Reviewed by:

Rafael Linden, Feevale University, Brazil
Mário Barroso, Portuguese National Institute of Legal Medicine and Forensic Sciences, Portugal

Copyright © 2023 Longman, Frampas, Lewis, Costa, Nilforooshan, Chambers and Bailey. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: M. Bailey, bS5iYWlsZXlAc3VycmV5LmFjLnVr

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.