Skip to main content

REVIEW article

Front. Chem., 30 September 2022
Sec. Analytical Chemistry

Use of whole-cell bioreporters to assess bioavailability of contaminants in aquatic systems

Yi ZhuYi Zhu1Evrim ElcinEvrim Elcin2Mengyuan JiangMengyuan Jiang1Boling LiBoling Li3Hailong WangHailong Wang4Xiaokai Zhang
Xiaokai Zhang1*Zhenyu WangZhenyu Wang1
  • 1School of Environmental and Civil Engineering, Institute of Environmental Processes and Pollution Control, Jiangnan University, Wuxi, China
  • 2Department of Agricultural Biotechnology, Division of Enzyme and Microbial Biotechnology, Faculty of Agriculture, Aydın Adnan Menderes University, Aydın, Turkey
  • 3School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou, China
  • 4Biochar Engineering Technology Research Center of Guangdong Province, School of Environmental and Chemical Engineering, Foshan University, Foshan, China

Water contamination has become increasingly a critical global environmental issue that threatens human and ecosystems’ health. Monitoring and risk assessment of toxic pollutants in water bodies is essential to identifying water pollution treatment needs. Compared with the traditional monitoring approaches, environmental biosensing via whole-cell bioreporters (WCBs) has exhibited excellent capabilities for detecting bioavailability of multiple pollutants by providing a fast, simple, versatile and economical way for environmental risk assessment. The performance of WCBs is determined by its elements of construction, such as host strain, regulatory and reporter genes, as well as experimental conditions. Previously, numerous studies have focused on the design and construction of WCB rather than improving the detection process and commercialization of this technology. For investigators working in the environmental field, WCB can be used to detect pollutants is more important than how they are constructed. This work provides a review of the development of WCBs and a brief introduction to genetic construction strategies and aims to summarize key studies on the application of WCB technology in detection of water contaminants, including organic pollutants and heavy metals. In addition, the current status of commercialization of WCBs is highlighted.

1 Introduction

With the acceleration of industrialization, pollution of aquatic systems is increasing more rapidly than ever (Maslova et al., 2019; Liu et al., 2021), which is undoubtedly worse in areas where water resources are already scarce. It has been reported that over 420 billion cubic meters of sewage are discharged into freshwater systems and seas globally every year, resulting in the pollution of 5.5 trillion cubic meters of freshwater, which is more than 14% of the world’s total runoff (Liang and Yu, 2018). Due to water scarcity, sewage must be used to irrigate farmland in many places (Xue et al., 2019), which may reduce soil fertility and destroy soil structure, resulting in reduced crop yields (Urbano et al., 2017). In addition, food crops and vegetables tend to accumulate harmful substances such as heavy metals exceeding the allowable limit for pollutant intake, which threatens human health through the food chain (Lei et al., 2015). Therefore, the detection, monitoring and risk assessment of various pollutants in aquatic systems is an essential task for environmental decision makers and of critical importance for human development and ecological protection.

The concentration of pollutants is an important indicator for analyzing their environmental risks and their impact on ecology as well as human health (Alamgir et al., 2017; Majeed et al., 2021). In general, analytical methods used for the detection of contaminants in polluted water can be roughly divided into five categories: electrochemical, chromatographic, atomic spectroscopic, fluorescence-based, and colorimetric (Alhamlan et al., 2015; Zolkefli et al., 2020). The corresponding specific detection methods based on the principles of these five methods can be selected according to the target analyte(s). Atomic spectroscopy is usually used for the detection of heavy metals in aquatic systems; however, chromatography is the first choice when there is organic pollution (Petrovic et al., 2010; Rathi et al., 2021). The electrochemical method can be applied to the abovementioned situations simultaneously (Ding et al., 2021). Based on numerous studies in recent years on the detection of contaminants in polluted waters (Abdullah et al., 2018; Kalaiyarasan et al., 2020; Wang et al., 2020; Brahmkhatri et al., 2021), it can be seen that traditional methods are still preferred research tools since they remain as the workhorse for chemical identification and quantification. Chemical instrumental methods are used to analyze the total concentrations of pollutants (Kolpin et al., 2002). However, the total concentration of a contaminant is not always related to its toxicity, it has been demonstrated that bioavailability is a prerequisite for toxicity (Wells et al., 2005a; Fairbrother et al., 2007; Din et al., 2019). In other words, the chemical analysis data are inadequate to efficiently reflect the biological impacts of toxic substances (Axelrod et al., 2016). Therefore, the bioassays based on numerous biological entities including microorganisms such as microalgae, bacteria and yeasts are gaining importance in the last decades. Increasingly, during the environmental risk assessment process, the contaminants bioavailability has become the most important parameter relating to toxicity (Wells, 2012; Zhang et al., 2020a).

In recent decades, whole-cell bioreporter (WCB) technology has demonstrated excellent performance in pollution detection and offers extraordinary application potential (Elad and Belkin, 2017; Gui et al., 2017; Zhang et al., 2022a). WCBs are living organisms that are engineered to sense physical or chemical entities in the environment, and in response generate electrochemical or optical signals by the action of reporter genes as a “report” that can be easily quantified (See Figure 1, Belkin, 2003; Dhyani et al., 2022). Many studies have shown that WCBs can effectively detect various contaminants in aquatic systems, such as chromium (Cr) (Zhang et al., 2019), arsenic (As) (Sharma et al., 2013), lead (Pb) (Zhang et al., 2022a), pesticides (Tang et al., 2014) and petroleum hydrocarbons (Jiang et al., 2021). In addition, WCBs have been demonstrated to be simple, portable, cost effective, sensitive and rapid compared to traditional methods (Zhang et al., 2017; He et al., 2018; Zeng et al., 2021; Dhyani et al., 2022). That’s why WCB technology offers an ideal technique to address the shortcomings of analysis via chemical instrumental methods for environmental risk assessment. In this paper, we reviewed the current status of WCBs for the detection of aqueous contaminants. The development of WCBs and principles of their use are briefly presented. Then, recent studies on the detection of heavy metals and organic substances in aquatic environments using WCB technology is surveyed. Future research directions for WCBs are then discussed, which may offer guidance for environmental scientists who would like to consider working in this field.

FIGURE 1
www.frontiersin.org

FIGURE 1. Diagram of the sensing mechanism of a bacterial Class I and Class II whole-cell bioreporters.

2 The development of whole-cell bioreporter technology

A very early example of the development of WCB can be traced back to a seminal paper in 1990, when investigators in the laboratory of Gary Sayler constructed a bacterial sensor which can produce bioluminescence signal for naphthalene detection (King et al., 1990). Since then, WCB technology has been developing over more than 30 years, and genetically modified WCBs are being designed to detect the bioavailability or toxicity of an increasing number of environmental contaminants. WCBs can be divided into three categories: Class I, Class II and Class III, with classification based on how molecular recognition occurs, how recognition is converted into a signal and what parameter is sensed (van Der Meer et al., 2004). Class I and Class II are inducible WCB systems (lights-on) (Figure 1, Belkin, 2003; Wells et al., 2005b) emitting a measurable signal upon activation by target analytes and stress conditions, respectively, while Class III is a constitutive WCB system (lights-off) showing signal decrease upon exposure to toxic agents (Struss et al., 2010; Woutersen et al., 2011). Class I WCB is a target-specific strain that is constructed by using particular, tightly-regulated promoter involved in a specific genetic regulatory mechanism, thus can only recognize or detect the target chemicals (e.g., metals, hormones, antibiotics, organic solvents) and do so by expressing reporter protein in the cell causing an increase in the output signal (Harms et al., 2006). Class II WCBs are stress-specific WCB strains that can produce an increasing output signal upon exposure to cellular stress conditions (e.g., DNA damage, protein damage, oxidative stress, heat shock) (Belkin et al., 1996). For both Class I and Class II, a linear or monotonic increase in the signal produced by the reporter allows quantitative determination of the bioavailable concentration of the analyte (Boyanapalli, 2006; Harms, 2007). Class III WCBs are those with a normally high signal level that display a decrease in output signal upon toxic response to a wide range of chemicals or stress conditions (Muhammad et al., 2021). These WCBs are nonspecific since the decrease in metabolic activity could be derived from the cumulative effects of multiple contaminants in a sample. Compared with the Class II and Class III, Class I WCB is the most extensively studied category, mainly due to its ability to measure the bioavailability of individual analytes.

Despite decades of development, Class I WCB construction has kept the same design principle, which is essentially coupling a sensing element (regulatory promoter sequence) to a reporter element (source of signal) so that the reporter element can be controlled by the sensing element. This design involves an artificial fusion of the natural regulatory circuit in a bacterium with a promoterless gene coding for a detectable signal molecule, often a protein. When exposed to a bioavailable chemical species, a transcription regulator will activate the relevant promoter in the regulatory circuit, followed by expression of the reporter gene, thus producing quantitative output signal (Belkin, 2003; Zeng et al., 2021). A generalized conceptual illustration that provides a representative summary of the process is shown in Figure 1. Such WCBs have shown great potential for detecting the bioavailability of the contaminants of interest (Magrisso et al., 2008; Jiang et al., 2015; Brányiková et al., 2020). So far, most studies have focused on the construction strategies of WCB rather than improving the detection process despite significant developments in WCB technology and, while commercialized, this technology has not yet become commercially dominant compared to other approaches in environmental analysis. This is because developing useful WCBs is difficult for non-biological experts, and the only experts who make WCBs know how to use them well (Zhang et al., 2022a). Since WCB technology is based on a live cell, scientists also have been working on the immobilization of WCBs by integrating them into hydrogel polymers using different techniques such as entrapment, covalent attachment and encapsulation and employing these WCB-hydrogel on different platforms such as 3D-printed materials and fiber optics for their on-site monitoring application (Lopreside et al., 2019). However, how to use this technology remains unfamiliar to many scientific researchers and environmental practitioners. As mentioned above, WCB has unique advantages for measurement of contaminants in aqueous environments, thus, it needs to be a widely accepted technology.

The factors mentioned above have limited the dissemination of WCB technology and its commercialization. However, many studies have demonstrated successfully implementation of WCB in environmental research. In 2000, for the first time, Sayler and Ripp used the genetically modified microorganisms to monitor field bioremediation processes (Sayler and Ripp, 2000), demonstrating the field applicability of WCB technology. Since then, some microbial WCBs have been successfully commercialized. However, many of the commercially available WCBs belong to Class III, and it is crucial to develop more specific WCB assays (Class I) to be commercialized for the detection of specific contaminants.

3 Design and construction of whole-cell bioreporter

3.1 Regulatory genes

Regulatory proteins and reporter genes are an important part of WCBs, especially regulatory proteins have been referred to as the heart of the Class I and Class II WCBs (van Der Meer et al., 2004). In the classic method of constructing a WCB, the responsive genes plus promoter or only the promoter itself is fused to a reporter gene without its promoter. The fused gene elements can be constructed on a plasmid and then the recombinant plasmid can be transformed into a host cell (Gupta et al., 2019; Liu et al., 2022). When applied to the detection of target compounds or stress factors, the transcriptional regulators in these WCBs stimulate the promoters, which leads to the expression of downstream reporter genes and the increase of the output signal for Classes I and II (Shin, 2011). Therefore, the sensitivity and function of the WCBs depend on the responsiveness of regulatory gene circuits to the tested species.

The main mechanism of how regulatory proteins work involves an effector-binding response to chemical species with structures that enable cognate recognition (Bilal and Iqbal, 2019; Liu et al., 2022). In some cases, targets with structural similarity may all provoke a response. Studies have shown that regulatory proteins that react with benzene also react with ethylbenzene and xylene (Kim et al., 2005). For example, with respect to heavy metals, one study showed how the regulatory proteins that can detect cadmium (Cd) may also detect other heavy metal ions (Biran et al., 2000). In another example, Li et al. (2022) found that the construction of Pb-specific WCB can also be applied for the detection of Cd. Thus, WCBs can vary from highly specific to selective. Some investigators pursue specificity and selectivity studies to tailor selective versus specific response by random mutagenesis of promoters or amino acid substitutions of regulatory proteins. For example, Kim et al. (2020) modulated the selectivity of the promoter regulatory protein, ZntR, of znt-operon of E. coli which is used to sense Cd, mercury (Hg) and zinc (Zn). By site-directed engineering of the metal-binding region of ZntR protein, the WCBs in their study found to be able to sense new metalloid species such as Cr and Pb. In another study, Guo et al. (2019) showed that the sensitivity of the WCB can be enhanced by tuning the molecular ratio of the promoter regulatory proteins. Shpigel et al. (2021) aimed to enhance the performance of their WCBs for the detection of trace explosives, 2,4-dinitrotoluene (DNT) and 2,4,6-trinitrotoluene (TNT). They applied three rounds of random mutagenesis of promoters, yqjF and azoR, selecting the best performing variant in each round for the next one, and they reported that the WCB in their study had much lower background signal with a 3-fold reduction in the limit of detection for DNT. Over the decades, many studies have been conducted to gain insights into the molecular mechanisms for the construction of WCBs (Díaz and Prieto, 2000; Looger et al., 2003; Bilal and Iqbal, 2019) and these efforts have greatly promoted the development of increasingly diverse and fit-for-purpose WCB technology.

3.2 Reporter genes

Based on the output signal, widely employed reporter elements are genes encoding β-galactosidase (lacZ), luciferase (luxCDABE) and green fluorescent protein (gfp) (Su et al., 2011). Studies have found that β-galactosidase is relatively stable, and when X-gal (a split substrate of β-galactose bonds) is used as a substrate for hydrolysis, β-galactosidase catalyzes the production of blue products that are convenient for optical detection and observation (i.e., by eye or visible spectroscopy, Casadaban et al., 1983; Gierut et al., 2014; Wallenfels and Weil, 1972). Of course, when the reaction substrate is labeled with luminescence or fluorophore, the luminescence or excited fluorescence of the reaction can also be used as a detection basis (Xu et al., 2013; Doura et al., 2016). At the same time, if p-aminophenyl-β-D-galactopyranoside (PAPG) is used as a substrate, the p-aminophenol (PAP) produced by the enzymatic hydrolysis can also be detected by an electrochemical method, so as to determine the expression status of β-galactosidase (Matsui et al., 2006; Biran et al., 2010). Owing to these advantages, the lacZ gene is widely used as a reporter gene in genetic engineering. In recent years, researchers combined lacZ gene with the gene encoding urease for the construction of WCB to detect Cd and showed a very low limit of detection of 10 ppm (Shetty et al., 2003). In addition, the lacZ gene can also be used to construct WCB for the detection of organic pollutants. Peng et al. (2010) constructed Escherichia coli bioreporter using the lacZ gene for detection of phenol, they found that the β-galactosidase activity of PEDRP34 was about twice that of PEDRP14 with 0.1–5 μM, also implicating the importance of the host strain (vide infra).

Bioluminescence, which uses luciferase to produce light is another most commonly used reporter protein for the design of WCBs. Engebrecht et al. (1983) isolated the complete lux cassette (luxCDABE) from bioluminescent bacteria, Vibrio fischeri, and the recombinant E. coli constructed on this basis was the first to generate bioluminescence without aldehyde addition. Luciferase can be found in various organisms such as firefly luciferase (encoded by luc) and sea pansy luciferase (encoded by ruc) (Wilson and Hastings, 1998), and bacterial luciferase-based reporter elements (luxAB or luxCDABE) are employed frequently by WCBs (Close et al., 2009). It has long been shown to be applicable in research such as the usage of WCBs for detection of contaminants and even the number of bacterial species (Ilina et al., 2018). Under aerobic conditions, bacterial luciferase oxidizes reduced riboflavin mononucleotide (FMNH2) and long-chain aldehydes, and this reaction produces a blue-green light with a peak wavelength of 490 nm (Close et al., 2012). Bhattacharyya et al. (2005) constructed five luminescent WCBs for the measurement of chlorinates in groundwater and found that the WCB results agreed well with the chemical analyses. Figure 2 shows a specific experimental process of how bioluminescence-based WCB works from our previous studies; however, in practice the same process may be applicable to other reporter genes that produce an optical signal.

FIGURE 2
www.frontiersin.org

FIGURE 2. In the specific experimental process, the bioluminescence signal intensity is analyzed by fitting the curve under different concentrations or time periods of the pollutants to be tested (taking Zn as an example, unpublished data).

The green fluorescent protein (GFP) firstly isolated from crystal jellyfish Aequorea victoria (Ormö et al., 1996) is also an important reporter element. Its potential to be successfully expressed in a wide variety of species without any exogenous substrate or ATP requirements along with its small size (238 amino acids) are the reasons why it has become a commonly used reporter protein (Oertner, 2006). GFP is an auto fluorescent protein emitting a fluorescent signal at 508 nm upon ultraviolet or blue light excitation, and requires only oxygen for its expression (Craggs 2009). The shortcomings of the gfp-based WCBs are a high background signal and a slow response to contaminants (Shin, 2011). Many studies have shown that the enhanced green fluorescent protein (EGFP) has superior stability, emit brighter fluorescence and egfp-based WCBs have become an effective tool for detection of bioavailable species (Roberto et al., 2002; Wells et al., 2005c).

In addition to the aforementioned commonly used reporter genes for the construction of bioreporters, some other genes can also be incorporated into the design and construction of WCBs. For example, the Renilla luciferase gene, which only requires coelenterazine and oxygen to produce blue light with a wavelength of 480 nm after expression (Farzannia et al., 2015). Another interesting gene is crtA which is responsible for carotenoid synthesis (Yagi, 2007), has also been used as reporter gene for the construction of WCB.

3.3 Host strain

When constructing a WCB, besides the reporter gene, the choice of host strain is also particularly important. A WCB is a living organism that is typically derived from bacteria as a host strain, but fungi, yeasts or microalgae can also be used. And the cell functional strategies are also different when exposure to pollutant which is mainly governed by regulatory genes and reporter genes. For different target compounds, suitable organisms with relevant detoxification, degradation or other metabolic pathways for a particular contaminant or group of contaminants should be selected as host cells also considering the actual environmental conditions. This is because the sensitivity and response of individual strains vary under the stress of different contaminants (Phyo et al., 2021). For example, for the construction of WCB to detect mercury, Din et al. (2019) isolated mercury-resistant bacteria, an Enterobacter cloacae strain, from a contaminated soil environment. They reported that their bioreporter was both more sensitive and faster than other bireporters constructed with model E. coli bacterial strains. Han et al. (2019) isolated salt-tolerant Platymonas subcordiformis from sea species of motile microalgae for the construction of WCB and found that this WCB showed good sensitivity to Cu under a wide range of salinity, temperature and light levels. In addition, the host cell can also set some restrictions during the detection process, such as induction temperature and test media used to culture the WCB (Hynninen and Virta, 2010). However, some strains for constructing WCBs are isolated from wild-type bacteria that can survive in a very wide array of mineral media.

The bacterium E. coli has been widely used as a host cell for WCB to measure the genotoxicity of typical environmental contaminants such as inorganic and organic compounds (Yoon et al., 2016; Ali et al., 2021). However, in addition to E. coli, other Gram-negative bacteria such as Alcaligenes eutrophus (Peitzsch et al., 1998; Leth et al., 2002) and Cupriavidus metallidurans (Magrisso et al., 2009) as well as Gram-positive bacteria such as Bacillus subtilis and Staphylococcus aureus (Tauriainen et al., 1998; Bondarenko et al., 2008) have also been widely used for the construction of WCBs. Aside from bacteria, fungi, yeasts and algae (Sanseverino et al., 2009; Bullerjahn et al., 2010) have been used as hosts for contaminant detection, albeit to a lesser degree.

4 Application of whole-cell bioreporter for the measurement of pollutants in aquatic environment

As discussed above, compared with the traditional methods of contaminant detection, WCB technology reflects the bioavailability of contaminants and is capable of being more sensitive, time and labor saving. In recent years, many studies have been conducted using this technology to measure different types of bioavailable contaminants in aquatic systems. However, as mentioned earlier, the popularization of this technology to environmental researchers is the key to promoting its development into a standard detection method for environmental pollutants. In this section, some recent studies that primarily focus on Class I WCBs were reviewed, at the same time, Class II and III WCBs were briefly discussed.

4.1 Organic contaminants

Organic pollutants may enter aquatic systems through different ways, for example, direct discharge of untreated industrial or domestic sewage, oil spills from shipping or offshore exploration, and infiltration of soil contaminants such as pesticide spraying (Kostianoy et al., 2020; Lamba et al., 2020; Zhou et al., 2020). Recent studies have reported WCBs as detection tools for measuring bioavailable organic pollutants in water and achieved considerable results (Jiang et al., 2019; Muurinen et al., 2019; Voon et al., 2022). The first WCB was constructed for the detection of naphthalene which is an organic pollutant (King et al., 1990). Since then, many kinds of organic pollutants such as phenol (Han et al., 2019), amoxicillin (Zhao et al., 2021), chloroform (Ma et al., 2020), naphthalene (Sun et al., 2017), and testosterone (Moscovici et al., 2020) have been evaluated. Table 1 summarizes the recent studies on the application of WCB to detect organic compounds in water. As shown in Table 1, the sensitivities of WCBs toward many organic contaminants, such as naphthalene, phenanthrene and toluene, have been achieved in μg/L range similar to the sensitivity of instrumental analysis (He et al., 2018; Hurtado-Gallego et al., 2018; Muurinen et al., 2019). This indicates the WCB technology is sensitive enough to assess the environmental risk of organic contaminants and approach the allowed concentration by environmental regulations in the mg/L‒level (WHO, 2021, in which the allowable concentrations of organic contaminants in drinking water are listed).

TABLE 1
www.frontiersin.org

TABLE 1. Whole-cell bioreporters used in the detection of organic pollutants.

In the aqueous environments, many different types of contaminants often coexist. Studies have also shown that one type of WCB can be used for detection of multiple different organic pollutants (Ko and Kong, 2017; Patel et al., 2019) which is an innovative technology for target contaminants. Patel et al. (2019) found that the WCB used in their study was highly sensitive to both monoaromatic and polyaromatic hydrocarbons in industrial wastewater samples, with a detection limit in the range of 0.1–1 μM. Chumjai and Vangnai (2020) also reported that WCB can measure the genotoxicity of a variety of combined pollutants. The hidden mechanism could be that regulatory proteins can respond to chemicals with similar structure that can fit into effector-binding, as discussed in Section 3.1. In addition, some WCBs have been constructed for assessment of one specific contaminant bioavailability and have achieved good results. For instance, Sun et al. (2017) showed that the WCB adopted by the study can effectively respond to a low concentration of 0.01 μM naphthalene, showing high specificity and sensitivity and not responding to other polycyclic aromatic hydrocarbons. Wang et al. (2021) also demonstrated that the WCB they used had a low limit of detection and a wide measurement range (from 0.05 to 500 μM) for the detection of the specific pollutant, toluene.

Antibiotic residues in water can strongly affect water quality which may also arouse the accumulation of antibiotic resistance genes. In order to construct WCBs for detection of an antibiotic, an antibiotic-sensitive promoter should be fused with a reporter gene (Parthasarathy et al., 2018; Ma et al., 2020). Melamed et al. (2012) investigated the response of different WCBs and found that each WCB can respond to a specific antibiotic. They thus demonstrated the ability of WCBs for the detection of unknown antibiotics in natural water. Recently, a tetracycline WCB was constructed for measuring water samples that had a detection limit of 5 μg/L making measurements in field conditions possible (Muurinen et al., 2019). Under natural conditions, differences in physical and chemical properties of water will be an important challenge factor affecting the performance of WCB. Zhang et al. (2014) found that pH strongly affects the measurement of bioavailable tetracycline. Therefore, it is of great importance to construct WCBs with high activity in complex water environments.

4.2 Heavy metals

Compared with organic pollutants, heavy metals have more adverse effects on global public health and various types of ecosystems due to their toxicity, mobility and persistence (Pujari and Kapoor, 2021). To cope with the complex requirements from environmental elements and necessary technical support, the WCB is a good tool for detection of heavy metal contamination.

The assessment of the heavy metal bioavailability is a hot topic in the research of WCBs. Table 2 summarizes the studies that applied WCB technology to detect various heavy metals such as (van Genuchten et al., 2018), Cr (Kim et al., 2020), Cd (Hui et al., 2021), copper (Cu) (Pang et al., 2020), mercury (Hg) (He et al., 2018), antimony (Sb) (Kim et al., 2020), Pb (Zhang et al., 2017), silver (Ag) (Hurtado-Gallego et al., 2019a), iron (Fe) (Blanco-Ameijeiras et al., 2019), titanium (Ti) (Hurtado-Gallego et al., 2019a), zinc (Zn) (Kim et al., 2020), cobalt (Co.) (Martin-Betancor et al., 2017), and nickel (Ni) (Cayron et al., 2017). Different WCBs may have different sensitivities for the same metal. A WCB Acinetobacter DF4/PUTK2 strain carrying luciferase genes luxCDABE was constructed for the measurement of Pb in water by Muhammad et al. (2021), who found that the WCB is sensitive to Pb in the concentration range from 19.25 to 15,000 mg/L. Kessler et al. (2012) demonstrated that E. coli zntA promoter could effectively detect Pb in a concentration range from 0.0012 to 12.5 mg/L and that a toxic effect appeared at higher Pb concentrations (>12.5 mg/L). Therefore, different WCBs can be selected according to the level of Pb pollution in targeted water. For example, the WCB Acinetobacter DF4/PUTK2 may be a good tool for detection of higher Pb concentrations in wastewater, whereas E. coli zntA could be applied to detect the lower Pb concentrations in drinking water (Kessler et al., 2012; Muhammad et al., 2021).

TABLE 2
www.frontiersin.org

TABLE 2. Whole-cell bioreporter used for heavy metal detection in aquatic system.

When constructing WCBs, it is important to note possible toxic effects of analytes. It has been reported that heavy metals (particularly non-essential metals) can be toxic to most bacteria at exceptionally low concentrations (Lemire et al., 2013). Therefore, in many WCBs, the detoxification genes can be selected to enhance the tolerance of WCB to heavy metals (Zeng et al., 2021). For instance, zntA and cadA which are two typical metal transporter protein-coding genes can be used to engineer WCBs to survive in extreme environments (Biran et al., 2000). Zhang et al. (2022b) demonstrated that zntA-based WCB can measure Pb bioavailability in a wide concentration range of 1.2 μg/L–12.5 mg/L, which makes this zntA-based WCB an effective tool for environmental Pb pollution risk assessment. Deletion of metal exporter genes (such as copA) can cause intracellular heavy metal accumulation, which may enhance the sensitivity of WCBs at low metal exposure conditions (Kang et al., 2018). Therefore, the difference in detection limits of WCBs is the key to determine at which level of water pollution detection they can be applied to. As shown in Table 2, the limit of detections of many WCBs for Cd, Hg, Cu and As in water are at the μg/L level, which are comparable to allowable limits for metals in water set in National Primary Drinking Water Regulations (US EPA, 2017). This further indicates that WCB technology can be applied for accurate environmental risk assessment.

Heavy metals can occur in different forms which can strongly affect the metal bioavailability and also determine the dose response of WCBs during the detection process. Zhang et al. (2017) used WCB for the detection of Pb and found that Pb can combine with the ligands such as EDTA, humic acid and natural dissolved organic carbon in aqueous solution which makes it less bioavailable. They also showed that the bioreporter data agreed well with the speciation model result. Another related study showed that when considering the effect of dissolved organic carbon as a ligand on the effect of Pb bioavailability, the WCB data were also in good agreement with the speciation model data (Zhang et al., 2020a). Since the speciation model has been widely used in the environmental risk assessment of heavy metal pollution, this study further confirmed the possibility of applying the WCB technology to the risk assessment of Pb in natural waters. Moreover, slight differences in experimental conditions such as pH, cell density and medium composition may result in different detection limits (Zhang et al., 2022a). Of course, selecting the most suitable carrier strain is also an important measure to reduce the detection limit of the target heavy metal (Ivask et al., 2009). Both Acinetobacter baylyi (Cui et al., 2018) and Platymonas subcordiformis (Han et al., 2019) were used as host cells for the constructing WCBs and testing bioavailable Cu in water. The difference between the two experimental results is that the detection limit of the latter is much lower than that of the former. The possible reason could be that Han et al. (2019) selected microalgae in the selected sea area, which are salt-tolerant and best adapted to temperature and radiation. Compared with the bioreporter strain of Cui et al. (2018), it had a higher fitness for the measured environment. The relationship between the concentration of metal cation and its bioavailability is evident; it is worth noting that both nitrate (NO3-) and carbonate (CO32-) ions can modulate the bioavailability of the metal (Rodea-Palomares et al., 2009). This demonstrates that the chemical properties of water environment are also the key factors affecting the detection results of WCB when used to detect the bioavailability of heavy metals in natural water. To our knowledge, there is no standard WCB method for environmental risk assessment. To address this issue, standard validation methods that taking environmental factors into consideration need to be combined with WCB research to facilitate their application to environmental risk assessment.

4.3 Class II and class III bioreporters

In addition to the widely investigated Class I WCB, other types of WCBs, namely Class II and Class III are also commonly used. In fact, these two types of WCBs have been more widely commercialized for water monitoring. Although the target analyte varies in different studies, the key point is that the stress response mechanism of Class II WCBs is under external pressure. Numerous studies have been carried out for investigation of the oxidant and antioxidant properties of chemicals by using WCBs (Senevirathna et al., 2009; Lim et al., 2019). To investigate the oxidative stress of the pollutants, as early as 1996 in Belkin’s laboratory, E. coli DPD2515 and E. coli DPD2511 strains of WCBs were constructed for the detection of hydrogen peroxide (H2O2) and superoxide (O2). They further indicated that the WCBs can be applied for environmental monitoring and studying cellular responses to oxidative hazards (Belkin et al., 1996). Hartono et al. (2018) explored the oxidative stress and cellular damage of multiwalled carbon nanotubes (MWCNT) to WCB and observed that membrane damage is a major cause of MWCNT toxicity. Hurtado-Gallego et al. (2019b) used cyanobacterial bioreporters for (reactive oxygen species) ROS detection and found that both WCBs can detect oxidative stress caused by emerging pollutants in aquatic system.

Class III WCB is also known as ‘lights-off’ WCB, which is an extension of the biotoxicity method (Belkin, 2003). The mechanism of this WCB is that a decrease in light emission is detected upon exposure to toxic compound(s) and/or stress conditions. This is, in whole or in part, because the ATP or reducing power required by cellular metabolism for the generation of signal (e.g., bioluminescence) may be affected by any factor that has an influence on this metabolism, thus resulting in a decrease of signal output (Mateo et al., 2015). Studies have shown that cyanobacterial bioreporters constructed for Fe detection in water, light emission decreased when increasing concentrations of Fe are supplied to the WCBs (McKay et al., 2005; Hassler et al., 2009). The strain of Synechococcus sp. PCC7942 was constructed as a WCB by fusing phoA promoter to reporter genes luxAB from Vibrio harveyi to detect phosphorus (P) (Gillor et al., 2002). This phoA gene promoter is induced in P-deficient environment, and as the P concentration increases, luminescence decreases (Gillor et al., 2002). In addition to detecting the nutrient bioavailability, Class III WCBs can also be applied to detect general toxicity. Abd-El-Haleem et al. (2006) showed that the bioluminescence lights-off took place when the WCB was used for the detection of different heavy metals (Cu, Fe, Ni, Zn, Co., Cd, and Cr). Similarly, Muhammad et al. (2021) demonstrated that “lights-off” WCB was effective for Pb detection.

5 Outlook and perspectives

The WCBs described in this review have been demonstrated to be an ideal tool for the detection of contaminants in aquatic systems. Even though this technology has numerous advantages, several considerations must be addressed before WCBs can be more widely accepted and commercialized, including further shortening the response times, increasing cell sensitivity and improving cell selectivity. In addition, how to construct a useful WCB that can exhibit good performance in detection of contaminants is of high importance. Moreover, during the detection processes, the chemical components of the culture medium, pH of the medium and cell concentration at harvesting are important parameters that may strongly affect the performance of WCBs. Therefore, it is essential to provide guidance to both non-bioengineer researchers and environmental practitioners, and efforts should be made toward the development of standard methods. While this has been realized to some extent for certain types of WCBs, most prominently Class III WCBs, such guidance and standard methodology is not yet mature for Class I WCBs. The dissemination of a greater array of commercially available Class I WCBs would be very helpful in this regard, which will also promote their application in the field of environmental risk assessment.

Author contributions

YZ and XZ reviewed the literature, designed the concept, wrote the manuscript, and prepared the tables and figures. EE, MJ, BL, HW, and ZW revised the manuscript. All authors approved the manuscript for publication.

Funding

This research was supported by the National Natural Science Foundation of China (42,107,245) and China Postdoctoral Science Foundation Funded Project (2021M701455).

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

Abd-El-Haleem, D., Zaki, S., Abulhamd, A., Elbery, H., and Abu-Elreesh, G. (2006). Acinetobacter bioreporter assessing heavy metals toxicity. J. Basic Microbiol. 46, 339–347. doi:10.1002/jobm.200510122

PubMed Abstract | CrossRef Full Text | Google Scholar

Abdullah, I. H., Ahmed, N., Mohamed, M. A., Ragab, Fawzy M. A., Abdel-Wareth, M. T. A., and Allam, N. K. (2018). An engineered nanocomposite for sensitive and selective detection of mercury in environmental water samples. Anal. Methods 10, 2526–2535. doi:10.1039/c8ay00618k

CrossRef Full Text | Google Scholar

Alamgir, A., Khan, M. A., Shaukat, S. S., Khan, T. M. A., and Zubair, S. (2017). Water quality appraisal of keti bandar and shah bandar creeks of indus delta, sindh, Pakistan. Desalin. Water Treat. 70, 95–105. doi:10.5004/dwt.2017.20466

CrossRef Full Text | Google Scholar

Alhamlan, F. S., Al-Qahtani, A. A., and Al-Ahdal, M. N. (2015). Recommended advanced techniques for waterborne pathogen detection in developing countries. J. Infect. Dev. Ctries. 9, 128–135. doi:10.3855/jidc.6101

PubMed Abstract | CrossRef Full Text | Google Scholar

Ali, S. A., Mittal, D., and Kaur, G. (2021). In-situ monitoring of xenobiotics using genetically engineered whole-cell-based microbial biosensors: Recent advances and outlook. World J. Microbiol. Biotechnol. 37, 81. doi:10.1007/s11274-021-03024-3

CrossRef Full Text | Google Scholar

Axelrod, T., Eltzov, E., and Marks, R. S. (2016). Bioluminescent bioreporter pad biosensor for monitoring water toxicity. Talanta 149, 290–297. doi:10.1016/j.talanta.2015.11.067

PubMed Abstract | CrossRef Full Text | Google Scholar

Belkin, S. (2003). Microbial whole-cell sensing systems of environmental pollutants. Curr. Opin. Microbiol. 6, 206–212. doi:10.1016/s1369-5274(03)00059-6

PubMed Abstract | CrossRef Full Text | Google Scholar

Belkin, S., Smulski, D. R., Vollmer, A. C., Van Dyk, T. K., and LaRossa, R. A. (1996). Oxidative stress detection with Escherichia coli harboring a katG’::lux fusion. Appl. Environ. Microbiol. 62, 2252–2256. doi:10.1128/aem.62.7.2252-2256.1996

PubMed Abstract | CrossRef Full Text | Google Scholar

Bhattacharyya, J., Read, D., Amos, S., Dooley, S., Killham, K., and Paton, G. I. (2005). Biosensor-based diagnostics of contaminated groundwater: Assessment and remediation strategy. Environ. Pollut. 134, 485–492. doi:10.1016/j.envpol.2004.09.002

PubMed Abstract | CrossRef Full Text | Google Scholar

Bilal, M., and Iqbal, H. M. (2019). Microbial-derived biosensors for monitoring environmental contaminants: Recent advances and future outlook. Process Saf. Environ. Prot. 124, 8–17. doi:10.1016/j.psep.2019.01.032

CrossRef Full Text | Google Scholar

Biran, A., Yagur-Kroll, S., Pedahzur, R., Buchinger, S., Reifferscheid, G., Ben-Yoav, H., et al. (2010). Bacterial genotoxicity bioreporters. Microb. Biotechnol. 3, 412–427. doi:10.1111/j.1751-7915.2009.00160.x

PubMed Abstract | CrossRef Full Text | Google Scholar

Biran, I., Babai, R., Levcov, K., Rishpon, J., and Ron, E. Z. (2000). Online and in situ monitoring of environmental pollutants: Electrochemical biosensing of cadmium. Environ. Microbiol. 2, 285–290. doi:10.1046/j.1462-2920.2000.00103.x

PubMed Abstract | CrossRef Full Text | Google Scholar

Blanco-Ameijeiras, S., Cabanes, D. J. E., and Hassler, C. S. (2019). Towards the development of a new generation of whole-cell bioreporters to sense iron bioavailability in oceanic systems—Learning from the case of Synechococcus sp. PCC7002 iron bioreporter. J. Appl. Microbiol. 127, 1291–1304. doi:10.1111/jam.14277

PubMed Abstract | CrossRef Full Text | Google Scholar

Bondarenko, O., Rõlova, T., Kahru, A., and Ivask, A. (2008). Bioavailability of Cd, Zn and Hg in soil to nine recombinant luminescent metal sensor bacteria. Sensors 8, 6899–6923. doi:10.3390/s8116899

PubMed Abstract | CrossRef Full Text | Google Scholar

Boyanapalli, R. (2006). Construction and characterization of cyanobacterial bioreporters to assess nutrient (P, Fe) availability in marine environments. Ph.D. dissertation (Bowling Green: Bowling Green State University).

Google Scholar

Brahmkhatri, V., Pandit, P., Rananaware, P., D’Souza, A., and Kurkuri, M. D. (2021). Recent progress in detection of chemical and biological toxins in water using plasmonic nanosensors. Trends Environ. Anal. Chem. 30, e00117. doi:10.1016/j.teac.2021.e00117

CrossRef Full Text | Google Scholar

Brányiková, I., Lucáková, S., Kuncová, G., Trögl, J., Synek, V., Rohovec, J., et al. (2020). Estimation of Hg(II) in soil samples by bioluminescent bacterial bioreporter E. coli ARL1, and the effect of humic acids and metal ions on the biosensor performance. Sensors 20, 3138. doi:10.3390/s20113138

CrossRef Full Text | Google Scholar

Bullerjahn, G. S., Boyanapalli, R., Rozmarynowycz, M. J., and McKay, R. M. L. (2010). Cyanobacterial bioreporters as sensors of nutrient availability. Adv. Biochem. Eng. Biotechnol. 118, 165–188. doi:10.1007/10_2009_23

PubMed Abstract | CrossRef Full Text | Google Scholar

Casadaban, M. J., Martinezarias, A., Shapira, S. K., Chou, J., and Martinez-AriAs, A. (1983). β-galactosidase gene fusions for analyzing gene-expression in Escherichia coli and yeast. Methods Enzymol. 100, 293–308. doi:10.1016/0076-6879(83)00063-4

PubMed Abstract | CrossRef Full Text | Google Scholar

Cayron, J., Prudent, E., Escoffier, C., Gueguen, E., Mandrand-Berthelot, M. A., Pignol, D., et al. (2017). Pushing the limits of nickel detection to nanomolar range using a set of engineered bioluminescent Escherichia coli. Environ. Sci. Pollut. Res. 24, 4–14. doi:10.1007/s11356-015-5580-6

PubMed Abstract | CrossRef Full Text | Google Scholar

Chen, X. J., Jiang, X., Tie, C. J., Yoo, J., Wang, Y., Xu, M. Y., et al. (2019). Contribution of nonconsensus base pairs within ArsR binding sequences toward ArsR-DNA binding and arsenic-mediated transcriptional induction. J. Biol. Eng. 13, 53–12. doi:10.1186/s13036-019-0181-4

PubMed Abstract | CrossRef Full Text | Google Scholar

Chen, X., Yao, H., Song, D., Sun, G., and Xu, M. (2022). Extracellular chemoreceptor of deca-brominated diphenyl ether and its engineering in the hydrophobic chassis cell for organics biosensing. Chem. Eng. J. 433, 133266. doi:10.1016/j.cej.2021.133266

CrossRef Full Text | Google Scholar

Chumjai, N., and Vangnai, A. S. (2020). A colorimetric-based bioreporter for rapid genotoxicity monitoring using Escherichia coli. Sci. Asia. 46, 344. doi:10.2306/scienceasia1513-1874.2020.039

CrossRef Full Text | Google Scholar

Close, D. M., Ripp, S., and Sayler, G. S. (2009). Reporter proteins in whole-cell optical bioreporter detection systems, biosensor integrations, and biosensing applications. Sensors 9, 9147–9174. doi:10.3390/s91109147

PubMed Abstract | CrossRef Full Text | Google Scholar

Close, D., Xu, T., Smartt, A., Rogers, A., Crossley, R., Price, S., et al. (2012). The evolution of the bacterial luciferase gene cassette (lux) as a real-time bioreporter. Sensors 12, 732–752. doi:10.3390/s120100732

PubMed Abstract | CrossRef Full Text | Google Scholar

Craggs, T. D. (2009). Green fluorescent protein: Structure, folding and chromophore maturation. Chem. Soc. Rev. 38, 2865–2875. doi:10.1039/b903641p

PubMed Abstract | CrossRef Full Text | Google Scholar

Cregut, M., Hua, A., Jouanneau, S., Assaf, A., Cordella, C. B. Y., Thouand, G., et al. (2022). Screening of metallic pollution in complex environmental samples through a transcriptomic fingerprint method. Environ. Sci. Pollut. Res. 29, 1037–1050. doi:10.1007/s11356-021-15545-3

CrossRef Full Text | Google Scholar

Cui, Z., Luan, X., Jiang, H., Li, Q., Xu, G., Sun, C., et al. (2018). Application of a bacterial whole cell biosensor for the rapid detection of cytotoxicity in heavy metal contaminated seawater. Chemosphere 200, 322–329. doi:10.1016/j.chemosphere.2018.02.097

PubMed Abstract | CrossRef Full Text | Google Scholar

Dey, S., Baba, S. A., Bhatt, A., Dhyani, R., and Navani, N. K. (2020). Transcription factor based whole-cell biosensor for specific and sensitive detection of sodium dodecyl sulfate. Biosens. Bioelectron. X. 170, 112659. doi:10.1016/j.bios.2020.112659

PubMed Abstract | CrossRef Full Text | Google Scholar

Dhyani, R., Jain, S., Bhatt, A., Kumar, P., and Navani, N. K. (2022). Genetic regulatory element based whole-cell biosensors for the detection of metabolic disorders. Biosens. Bioelectron. X. 199, 113869. doi:10.1016/j.bios.2021.113869

CrossRef Full Text | Google Scholar

Din, G., Hasan, F., Conway, M., Denney, B., Ripp, S., and Shah, A. A. (2019). Engineering a bioluminescent bioreporter from an environmentally sourced mercury-resistant Enterobacter cloacae strain for the detection of bioavailable mercury. J. Appl. Microbiol. 127, 1125–1134. doi:10.1111/jam.14399

PubMed Abstract | CrossRef Full Text | Google Scholar

Ding, Q., Li, C., Wang, H., Xu, C., and Kuang, H. (2021). Electrochemical detection of heavy metal ions in water. Chem. Commun. 57, 7215–7231. doi:10.1039/d1cc00983d

CrossRef Full Text | Google Scholar

Dı́az, E., and Prieto, M. a. A. (2000). Bacterial promoters triggering biodegradation of aromatic pollutants. Curr. Opin. Biotechnol. 11, 467–475. doi:10.1016/s0958-1669(00)00126-9

CrossRef Full Text | Google Scholar

Doura, T., Kamiya, M., Obata, F., Yamaguchi, Y., Hiyama, T. Y., Matsuda, T., et al. (2016). Detection of LacZ-positive cells in living tissue with single-cell resolution. Angew. Chem. Int. Ed. Engl. 55, 9772–9776. doi:10.1002/ange.201603328

CrossRef Full Text | Google Scholar

Elad, T., and Belkin, S. (2017). Reporter gene assays in ecotoxicology. Adv. Biochem. Eng. Biotechnol. 157, 135–157. doi:10.1007/10_2016_47

PubMed Abstract | CrossRef Full Text | Google Scholar

Elcin, E., Ayaydin, F., and Öktem, H. A. (2021). Formaldehyde biosensing in air using fluorescent bacterial bioreporter cells. Int. J. Environ. Anal. Chem., 1–19. doi:10.1080/03067319.2021.1998474

CrossRef Full Text | Google Scholar

Elcin, E., and Öktem, H. A. (2020). Inorganic cadmium detection using a fluorescent whole-cell bacterial bioreporter. Anal. Lett. 53, 2715–2733. doi:10.1080/00032719.2020.1755867

CrossRef Full Text | Google Scholar

Engebrecht, J., Nealson, K., and Silverman, M. (1983). Bacterial bioluminescence: Isolation and genetic analysis of functions from Vibrio fischeri. Cell 32, 773–781. doi:10.1016/0092-8674(83)90063-6

PubMed Abstract | CrossRef Full Text | Google Scholar

Fairbrother, A., Wenstel, R., Sappington, K., and Wood, W. (2007). Framework for metals risk assessment. Ecotoxicol. Environ. Saf. 68, 145–227. doi:10.1016/j.ecoenv.2007.03.015

PubMed Abstract | CrossRef Full Text | Google Scholar

Farzannia, A., Roghanian, R., Zarkesh-Esfahani, S. H., Nazari, M., and Emamzadeh, R. (2015). FcUni-RLuc: An engineered Renilla luciferase with fc binding ability and light emission activity. Analyst 140, 1438–1441. doi:10.1039/c4an01946f

PubMed Abstract | CrossRef Full Text | Google Scholar

Gierut, J. J., Jacks, T. E., and Haigis, K. M. (2014). Whole-mount X-Gal staining of mouse tissues. Cold Spring Harb. Protoc., pdb.prot073452–419. doi:10.1101/pdb.prot073452

PubMed Abstract | CrossRef Full Text | Google Scholar

Gillor, O., Hadas, O., Post, A. F., and Belkin, S. (2002). Phosphorus bioavailability monitoring by a bioluminescent cyanobacterial sensor strain. J. Phycol. 38, 107–115. doi:10.1046/j.1529-8817.2002.01069.x

CrossRef Full Text | Google Scholar

Gui, Q., Lawson, T., Shan, S., Yan, L., and Liu, Y. (2017). The application of whole cell-based biosensors for use in environmental analysis and in medical diagnostics. Sensors 17, 1623. doi:10.3390/s17071623

CrossRef Full Text | Google Scholar

Guo, M., Du, R., Xie, Z., He, X., Huang, K., Luo, Y., et al. (2019). Using the promoters of MerR family proteins as “rheostats” to engineer whole-cell heavy metal biosensors with adjustable sensitivity. J. Biol. Eng. 13, 70. doi:10.1186/s13036-019-0202-3

PubMed Abstract | CrossRef Full Text | Google Scholar

Gupta, N., Renugopalakrishnan, V., Liepmann, D., Paulmurugan, R., and Malhotra, B. D. (2019). Cell-based biosensors: Recent trends, challenges and future perspectives. Biosens. Bioelectron. X. 141, 111435. doi:10.1016/j.bios.2019.111435

PubMed Abstract | CrossRef Full Text | Google Scholar

Han, S., Zhang, Q., Zhang, X. C., Liu, X. M., Lu, L., Wei, J. F., et al. (2019). A digital microfluidic diluter-based microalgal motion biosensor for marine pollution monitoring. Biosens. Bioelectron. X. 143, 111597. doi:10.1016/j.bios.2019.111597

PubMed Abstract | CrossRef Full Text | Google Scholar

Hansen, M. G., Marcussen, H., Holm, P. E., and Brandt, K. K. (2019). Evaluation of pH-dependent metal speciation artifacts in whole-cell bioreporter analysis. J. Environ. Qual. 48, 199–204. doi:10.2134/jeq2018.10.0352

PubMed Abstract | CrossRef Full Text | Google Scholar

Harms, H. (2007). Biosensing of heavy metals. in Molecular microbiology of heavy metals. Editors D. H. Nies, and S. Silver (Springer Verlag Berlin Heidelberg), 143–157.

Google Scholar

Harms, H., Wells, M. C., and van der Meer, J. R. (2006). Whole-cell living biosensors—Are they ready for environmental application? Appl. Microbiol. Biotechnol. 70, 273–280. doi:10.1007/s00253-006-0319-4

PubMed Abstract | CrossRef Full Text | Google Scholar

Hartono, M. R., Kushmaro, A., Chen, X. D., and Marks, R. S. (2018). Probing the toxicity mechanism of multiwalled carbon nanotubes on bacteria. Environ. Sci. Pollut. Res. 25, 5003–5012. doi:10.1007/s11356-017-0782-8

PubMed Abstract | CrossRef Full Text | Google Scholar

Hassler, C. S., Havens, S. M., Bullerjahn, G. S., McKay, R. M. L., and Twissa, M. R. (2009). An evaluation of iron bioavailability and speciation in Western Lake Superior with the use of combined physical, chemical, and biological assessment. Limnol. Oceanogr. 54, 987–1001. doi:10.4319/lo.2009.54.3.0987

CrossRef Full Text | Google Scholar

He, W., Hu, Z. H., Yuan, S., Zhong, W. H., Mei, Y. Z., and Dai, C. C. (2018). Bacterial bioreporter–based mercury and phenanthrene assessment in Yangtze River Delta soils of China. J. Environ. Qual. 47, 562–570. doi:10.2134/jeq2017.07.0286

PubMed Abstract | CrossRef Full Text | Google Scholar

Hui, C. Y., Guo, Y., Wu, J., Liu, L., Yang, X. Q., Guo, X., et al. (2021). Detection of bioavailable cadmium by double-color fluorescence based on a dual-sensing bioreporter system. Front. Microbiol. 12, 696195. doi:10.3389/fmicb.2021.696195

PubMed Abstract | CrossRef Full Text | Google Scholar

Hurtado-Gallego, J., Leganés, F., Rosal, R., and Fernández-Piñas, F. (2019a). Use of cyanobacterial luminescent bioreporters to report on the environmental impact of metallic nanoparticles. Sensors 19, 3597. doi:10.3390/s19163597

CrossRef Full Text | Google Scholar

Hurtado-Gallego, J., Martin-Betancor, K., Rodea-Palomares, I., Leganes, F., Rosal, R., and Fernandez-Pinas, F. (2018). Two novel cyanobacterial bioluminescent whole-cell bioreporters based on superoxide dismutases MnSod and FeSod to detect superoxide anion. Chemosphere 201, 772–779. doi:10.1016/j.chemosphere.2018.03.012

PubMed Abstract | CrossRef Full Text | Google Scholar

Hurtado-Gallego, J., Redondo-Lopez, A., Leganes, F., Rosal, R., and Fernandez-Pinas, F. (2019b). Peroxiredoxin (2-cys-prx) and catalase (katA) cyanobacterial-based bioluminescent bioreporters to detect oxidative stress in the aquatic environment. Chemosphere 236, 124395. doi:10.1016/j.chemosphere.2019.124395

PubMed Abstract | CrossRef Full Text | Google Scholar

Hynninen, A., and Virta, M. (2010). Whole-cell bioreporters for the detection of bioavailable metals. in Whole cell sensing systems II: Applications. Editors S. Belkin, and M. B. Gu (Berlin: Springer), 31–63.

Google Scholar

Ilina, P., Ma, X., Sintim, H. O., and Tammela, P. (2018). Miniaturized whole-cell bacterial bioreporter assay for identification of quorum sensing interfering compounds. J. Microbiol. Methods 154, 40–45. doi:10.1016/j.mimet.2018.10.005

PubMed Abstract | CrossRef Full Text | Google Scholar

Ivask, A., Rõlova, T., and Kahru, A. (2009). A suite of recombinant luminescent bacterial strains for the quantification of bioavailable heavy metals and toxicity testing. BMC Biotechnol. 9, 41–15. doi:10.1186/1472-6750-9-41

PubMed Abstract | CrossRef Full Text | Google Scholar

Jiang, B., Li, G., Xing, Y., Zhang, D., Jia, J., Cui, Z., et al. (2017). A whole-cell bioreporter assay for quantitative genotoxicity evaluation of environmental samples. Chemosphere 184, 384–392. doi:10.1016/j.chemosphere.2017.05.159

PubMed Abstract | CrossRef Full Text | Google Scholar

Jiang, B., Song, Y., Liu, Z., Huang, W. E., Li, G., Deng, S., et al. (2021). Whole-cell bioreporters for evaluating petroleum hydrocarbon contamination. Crit. Rev. Environ. Sci. Technol. 51, 272–322. doi:10.1080/10643389.2020.1717907

CrossRef Full Text | Google Scholar

Jiang, B., Zhang, N., Xing, Y., Lian, L., Chen, Y., Zhang, D., et al. (2019). Microbial degradation of organophosphorus pesticides: Novel degraders, kinetics, functional genes, and genotoxicity assessment. Environ. Sci. Pollut. Res. 26, 21668–21681. doi:10.1007/s11356-019-05135-9

PubMed Abstract | CrossRef Full Text | Google Scholar

Jiang, B., Zhu, D., Song, Y., Zhang, D., Liu, Z., Zhang, X., et al. (2015). Use of a whole-cell bioreporter, Acinetobacter baylyi, to estimate the genotoxicity and bioavailability of chromium(VI)-contaminated soils. Biotechnol. Lett. 37, 343–348. doi:10.1007/s10529-014-1674-3

PubMed Abstract | CrossRef Full Text | Google Scholar

Kalaiyarasan, G., Joseph, J., and Kumar, P. (2020). Phosphorus-doped carbon quantum dots as fluorometric probes for iron detection. ACS Omega 5, 22278–22288. doi:10.1021/acsomega.0c02627

PubMed Abstract | CrossRef Full Text | Google Scholar

Kang, Y., Lee, W., Jang, G., Kim, B. G., and Yoon, Y. (2018). Modulating the sensing properties of Escherichia coli-based bioreporters for cadmium and mercury. Appl. Microbiol. Biotechnol. 102, 4863–4872. doi:10.1007/s00253-018-8960-2

PubMed Abstract | CrossRef Full Text | Google Scholar

Kessler, N., Schauer, J. J., Yagur-Kroll, S., Melamed, S., Tirosh, O., Belkin, S., et al. (2012). A bacterial bioreporter panel to assay the cytotoxicity of atmospheric particulate matter. Atmos. Environ. X. 63, 94–101. doi:10.1016/j.atmosenv.2012.09.048

CrossRef Full Text | Google Scholar

Kim, H., Jang, G., Kim, B. G., and Yoon, Y. (2020). Modulation of the metal(loid) specificity of whole-cell bioreporters by genetic engineering of ZntR metal-binding loops. J. Microbiol. Biotechnol. 30, 681–688. doi:10.4014/jmb.1911.11053

PubMed Abstract | CrossRef Full Text | Google Scholar

Kim, M. N., Park, H. H., Lim, W. K., and Shin, H. J. (2005). Construction and comparison of Escherichia coli whole-cell biosensors capable of detecting aromatic compounds. J. Microbiol. Methods 60, 235–245. doi:10.1016/j.mimet.2004.09.018

PubMed Abstract | CrossRef Full Text | Google Scholar

King, J., DiGrazia, P., Applegate, B., Burlage, R., Sanseverino, J., Dunbar, P., et al. (1990). Rapid, sensitive bioluminescent reporter technology for naphthalene exposure and biodegradation. Science 249, 778–781. doi:10.1126/science.249.4970.778

PubMed Abstract | CrossRef Full Text | Google Scholar

Ko, K. S., and Kong, I. C. (2017). Application of the freeze-dried bioluminescent bioreporter Pseudomonas putida mt-2 KG1206 to the biomonitoring of groundwater samples from monitoring wells near gasoline leakage sites. Appl. Microbiol. Biotechnol. 101, 1709–1716. doi:10.1007/s00253-016-7974-x

PubMed Abstract | CrossRef Full Text | Google Scholar

Kolpin, D. W., Furlong, E. T., Meyer, M. T., Thurman, E. M., Zaugg, S. D., Barber, L. B., et al. (2002). Pharmaceuticals, hormones, and other organic wastewater contaminants in U.S. Streams, 1999–2000: A national reconnaissance. Environ. Sci. Technol. 36, 1202–1211. doi:10.1021/es011055j

PubMed Abstract | CrossRef Full Text | Google Scholar

Kostianoy, A., Kostianaia, E. A., and Soloviev, D. M. (2020). Oil pollution in the Mediterranean waters of Egypt. Editors S. F. Elbeih, A. M. Negm, and A. Kostianoy (Cham, Switzerland: Springer), 305–328.

CrossRef Full Text | Google Scholar

Lamba, M., Sreekrishnan, T. R., and Ahammad, S. Z. (2020). Sewage mediated transfer of antibiotic resistance to River Yamuna in Delhi, India. J. Environ. Chem. Eng. 8, 102088. doi:10.1016/j.jece.2017.12.041

CrossRef Full Text | Google Scholar

Lei, L., Liang, D., Yu, D., Chen, Y., Song, W., and Li, J. (2015). Human health risk assessment of heavy metals in the irrigated area of Jinghui, Shaanxi, China, in terms of wheat flour consumption. Environ. Monit. Assess. 187, 647. doi:10.1007/s10661-015-4884-9

PubMed Abstract | CrossRef Full Text | Google Scholar

Lemire, J. A., Harrison, J. J., and Turner, R. J. (2013). Antimicrobial activity of metals: Mechanisms, molecular targets and applications. Nat. Rev. Microbiol. 11, 371–384. doi:10.1038/nrmicro3028

PubMed Abstract | CrossRef Full Text | Google Scholar

Leth, S., Maltoni, S., Simkus, R., Mattiasson, B., Corbisier, P., Klimant, I., et al. (2002). Engineered bacteria based biosensors for monitoring bioavailable heavy metals. Electroanalysis 14, 35–42. doi:10.1002/1521-4109(200201)14:1<35::aid-elan35>3.0.co;2-w

CrossRef Full Text | Google Scholar

Li, B., Zhang, X., Tefsen, B., and Wells, M. (2022). From speciation to toxicity: Using a “Two-in-One” whole-cell bioreporter approach to assess harmful effects of Cd and Pb. Water Res. 217, 118384. doi:10.1016/j.watres.2022.118384

PubMed Abstract | CrossRef Full Text | Google Scholar

Li, P. S., Wang, Y. M. Z., Yuan, X., Liu, X. Y., Liu, C. M., Fu, X. F., et al. (2021). Development of a whole-cell biosensor based on an ArsR-P-ars regulatory circuit from Geobacter sulfurreducens. Environ. Sci. Ecotechnology 6, 100092. doi:10.1016/j.ese.2021.100092

CrossRef Full Text | Google Scholar

Liang, S. M., and Yu, Z. Y. (2018). Global distribution fields of runoff depths calculated by empirical runoff coefficient. Arid Zone Res. 35, 1–11.

Google Scholar

Lim, S. D., Kim, S. H., Gilroy, S., Cushman, J. C., and Choi, W. G. (2019). Quantitative ROS bioreporters: A robust toolkit for studying biological roles of ROS in response to abiotic and biotic stresses. Physiol. Plant. 165, 356–368. doi:10.1111/ppl.12866

PubMed Abstract | CrossRef Full Text | Google Scholar

Liu, C., Yu, H., Zhang, B., Liu, S., Liu, C. G., Li, F., et al. (2022). Engineering whole-cell microbial biosensors: Design principles and applications in monitoring and treatment of heavy metals and organic pollutants. Biotechnol. Adv. 60, 108019. doi:10.1016/j.biotechadv.2022.108019

PubMed Abstract | CrossRef Full Text | Google Scholar

Liu, Y., Wang, P., Gojenko, B., Yu, J., Wei, L., Luo, D., et al. (2021). A review of water pollution arising from agriculture and mining activities in Central Asia: Facts, causes and effects. Environ. Pollut. 291, 118209. doi:10.1016/j.envpol.2021.118209

PubMed Abstract | CrossRef Full Text | Google Scholar

Looger, L. L., Dwyer, M. A., Smith, J. J., and Hellinga, H. W. (2003). Computational design of receptor and sensor proteins with novel functions. Nature 423, 185–190. doi:10.1038/nature01556

PubMed Abstract | CrossRef Full Text | Google Scholar

Lopreside, A., Calabretta, M. M., Montali, L., Roda, A., and Michelini, E. (2019). Live cell immobilization. in Handbook of cell Biosensors. Editor G. Thouand (Cham: Springer).

Google Scholar

Lopreside, A., Montali, L., Wang, B. J., Tassoni, A., Ferri, M., Calabretta, M. M., et al. (2021). Orthogonal paper biosensor for mercury(II) combining bioluminescence and colorimetric smartphone detection. Biosens. Bioelectron. X. 194, 113569. doi:10.1016/j.bios.2021.113569

CrossRef Full Text | Google Scholar

Ma, Z., Liu, J., Li, H., Zhang, W., Williams, M. A., Gao, Y., et al. (2020). A fast and easily parallelizable biosensor method for measuring extractable tetracyclines in soils. Environ. Sci. Technol. 54, 758–767. doi:10.1021/acs.est.9b04051

PubMed Abstract | CrossRef Full Text | Google Scholar

Magrisso, S., Belkin, S., and Erel, Y. (2009). Lead bioavailability in soil and soil components. Water Air Soil Pollut. 202, 315–323. doi:10.1007/s11270-009-9978-y

CrossRef Full Text | Google Scholar

Magrisso, S., Erel, Y., and Belkin, S. (2008). Microbial reporters of metal bioavailability. Microb. Biotechnol. 1, 320–330. doi:10.1111/j.1751-7915.2008.00022.x

PubMed Abstract | CrossRef Full Text | Google Scholar

Majeed, R., Fatima, S. U., Khan, M. A., Khan, M. A., and Shaukat, S. S. (2021). Spatio-temporal analysis of pollutants in Karachi coastal water. J. Environ. Qual. 42, 6–21.

Google Scholar

Martin-Betancor, K., Aguado, S., Rodea-Palomares, I., Tamayo-Belda, M., Leganes, F., Rosal, R., et al. (2017). Co, Zn and Ag-MOFs evaluation as biocidal materials towards photosynthetic organisms. Sci. Total Environ. 595, 547–555. doi:10.1016/j.scitotenv.2017.03.250

PubMed Abstract | CrossRef Full Text | Google Scholar

Maslova, A. A., Panarin, V. M., Grishakov, K. V., Rybka, N. A., Kotova, E. A., and Selezneva, D. A. (2019). Use of artificial neural networks to predict levels of air pollution and water bodies. Ekol. Prom. Ross. 23, 36–41. doi:10.18412/1816-0395-2019-8-36-41

CrossRef Full Text | Google Scholar

Mateo, P., Leganés, F., Perona, E., Loza, V., and Fernández-Piñas, F. (2015). Cyanobacteria as bioindicators and bioreporters of environmental analysis in aquatic ecosystems. Biodivers. Conserv. 24, 909–948. doi:10.1007/s10531-015-0903-y

CrossRef Full Text | Google Scholar

Matsui, N., Kaya, T., Nagamine, K., Yasukawa, T., Shiku, H., and Matsue, T. (2006). Electrochemical mutagen screening using microbial chip. Biosens. Bioelectron. X. 21, 1202–1209. doi:10.1016/j.bios.2005.05.004

PubMed Abstract | CrossRef Full Text | Google Scholar

McKay, R., Porta, D., Bullerjahn, G. S., Al-Rshaidat, M. M., Klimowicz, J. A., Sterner, R. W., et al. (2005). Bioavailable iron in oligotrophic Lake Superior assessed using biological reporters. J. Plankton Res. 27, 1033–1044. doi:10.1093/plankt/fbi070

CrossRef Full Text | Google Scholar

Melamed, S., Lalush, C., Elad, T., Yagur-Kroll, S., Belkin, S., and Pedahzur, R. (2012). A bacterial reporter panel for the detection and classification of antibiotic substances. Microb. Biotechnol. 5, 536–548. doi:10.1111/j.1751-7915.2012.00333.x

PubMed Abstract | CrossRef Full Text | Google Scholar

Moscovici, L., Riegraf, C., Abu-Rmailah, N., Atias, H., Shakibai, D., Buchinger, S., et al. (2020). Yeast-based fluorescent sensors for the simultaneous detection of estrogenic and androgenic compounds, coupled with high-performance thin layer chromatography. Biosensors 10, 169. doi:10.3390/bios10110169

CrossRef Full Text | Google Scholar

Muhammad, A.-R. H., Abu-Elreesh, G., Sedik, M., Moawad, H., Sabbor, A. T., and Abd-El-Haleem, D. (2021). Studying the behavior of the light-off bioreporter DF4/PUTK2 as a light-on assay against lead. Biocatal. Agric. Biotechnol. 35, 102069. doi:10.1016/j.bcab.2021.102069

CrossRef Full Text | Google Scholar

Muurinen, J., Pasupulate, A., Lappalainen, J., and Virta, M. (2019). Field-compatible protocol for detecting tetracyclines with bioluminescent bioreporters without pipetting steps. Luminescence 34, 249–254. doi:10.1002/bio.3602

PubMed Abstract | CrossRef Full Text | Google Scholar

Oertner, T. G. (2006). Aglow in the dark: The revolutionary science of biofluorescence. Nature 440, 280. doi:10.1038/440280a

CrossRef Full Text | Google Scholar

Ormö, M., Cubitt Andrew, B., Kallio, K., Gross Larry, A., Tsien Roger, Y., and Remington, S. J. (1996). Crystal structure of the Aequorea victoria green fluorescent protein. Science 273, 1392–1395. doi:10.1126/science.273.5280.1392

PubMed Abstract | CrossRef Full Text | Google Scholar

Pang, Y., Ren, X., Li, J., Liang, F., Rao, X., Gao, Y., et al. (2020). Development of a sensitive Escherichia coli bioreporter without antibiotic markers for detecting bioavailable copper in water environments. Front. Microbiol. 10, 3031. doi:10.3389/fmicb.2019.03031

PubMed Abstract | CrossRef Full Text | Google Scholar

Parthasarathy, R., Monette, C. E., Bracero, S. S., and Saha, M. (2018). Methods for field measurement of antibiotic concentrations: Limitations and outlook. FEMS Microbiol. Ecol. 94, fiy105. doi:10.1093/femsec/fiy105

PubMed Abstract | CrossRef Full Text | Google Scholar

Patel, R., Zaveri, P., Mukherjee, A., Agarwal, P. K., More, P., and Munshi, N. S. (2019). Development of fluorescent protein-based biosensing strains: A new tool for the detection of aromatic hydrocarbon pollutants in the environment. Ecotoxicol. Environ. Saf. 182, 109450. doi:10.1016/j.ecoenv.2019.109450

PubMed Abstract | CrossRef Full Text | Google Scholar

Peca, L., Nagy, C. I., Ordog, A., Vass, I., and Kos, P. B. (2017). Development of a bioluminescent cyanobacterial reporter strain for detection of arsenite, arsenate and antimonite. Environ. Eng. Manag. J. 16, 2443–2450. doi:10.30638/eemj.2017.252

CrossRef Full Text | Google Scholar

Peitzsch, N., Eberz, G. n., and Nies, D. H. (1998). Alcaligenes eutrophus as a bacterial chromate sensor. Appl. Environ. Microbiol. 64, 453–458. doi:10.1128/aem.64.2.453-458.1998

PubMed Abstract | CrossRef Full Text | Google Scholar

Peng, Z. X., Yan, Y. L., Xu, Y. Q., Takeo, M., Yu, H. Y., Zhao, Z. L., et al. (2010). Improvement of an E. coli bioreporter for monitoring trace amounts of phenol by deletion of the inducible (sigma)54-dependent promoter. Biotechnol. Lett. 32, 1265–1270. doi:10.1007/s10529-010-0317-6

PubMed Abstract | CrossRef Full Text | Google Scholar

Petrovic, M., Farré, M., de Alda, M. L., Perez, S., Postigo, C., Köck, M., et al. (2010). Recent trends in the liquid chromatography–mass spectrometry analysis of organic contaminants in environmental samples. J. Chromatogr. A 1217, 4004–4017. doi:10.1016/j.chroma.2010.02.059

PubMed Abstract | CrossRef Full Text | Google Scholar

Phyo, M. Y., Katermeran, N. P., Goh, J. X., and Tan, L. T. (2021). Trikoveramides A-C, cyclic depsipeptides from the marine cyanobacterium Symploca hydnoides. Phytochemistry 190, 112879. doi:10.1016/j.phytochem.2021.112879

PubMed Abstract | CrossRef Full Text | Google Scholar

Pujari, M., and Kapoor, D. (2021). Heavy metals in the ecosystem: Sources and their effects. in Heavy metals in the environment. Editors V. Kumar, A. Sharma, and A. Cerdà (Elsevier), 1–7.

CrossRef Full Text | Google Scholar

Rathi, B. S., Kumar, P. S., and Vo, D. V. N. (2021). Critical review on hazardous pollutants in water environment: Occurrence, monitoring, fate, removal technologies and risk assessment. Sci. Total Environ. 797, 149134. doi:10.1016/j.scitotenv.2021.149134

PubMed Abstract | CrossRef Full Text | Google Scholar

Roberto, F. F., Barnes, J. M., and Bruhn, D. F. (2002). Evaluation of a GFP reporter gene construct for environmental arsenic detection. Talanta 58, 181–188. doi:10.1016/s0039-9140(02)00266-7

PubMed Abstract | CrossRef Full Text | Google Scholar

Rodea-Palomares, I., González-García, C., Leganés, F., and Fernández-Piñas, F. (2009). Effect of pH, EDTA, and anions on heavy metal toxicity toward a bioluminescent cyanobacterial bioreporter. Arch. Environ. Contam. Toxicol. 57, 477–487. doi:10.1007/s00244-008-9280-9

PubMed Abstract | CrossRef Full Text | Google Scholar

Saidur, M. R., Aziz, A. R. A., and Basirun, W. J. (2017). Recent advances in DNA-based electrochemical biosensors for heavy metal ion detection: A review. Biosens. Bioelectron. X. 90, 125–139. doi:10.1016/j.bios.2016.11.039

PubMed Abstract | CrossRef Full Text | Google Scholar

Sanseverino, J., Eldridge, M. L., Layton, A. C., Easter, J. P., Yarbrough, J., Schultz, T. W., et al. (2009). Screening of potentially hormonally active chemicals using bioluminescent yeast bioreporters. Toxicol. Sci. 107, 122–134. doi:10.1093/toxsci/kfn229

PubMed Abstract | CrossRef Full Text | Google Scholar

Sayler, G. S., and Ripp, S. (2000). Field applications of genetically engineered microorganisms for bioremediation processes. Curr. Opin. Biotechnol. 11, 286–289. doi:10.1016/s0958-1669(00)00097-5

PubMed Abstract | CrossRef Full Text | Google Scholar

Schirmer, C., Posseckardt, J., Kick, A., Rebatschek, K., Fichtner, W., Ostermann, K., et al. (2018). Encapsulating genetically modified Saccharomyces cerevisiae cells in a flow-through device towards the detection of diclofenac in wastewater. J. Biotechnol. 284, 75–83. doi:10.1016/j.jbiotec.2018.08.003

PubMed Abstract | CrossRef Full Text | Google Scholar

Senevirathna, W., Kiro, R., Rosen, R., Popov, I., Belkin, S., and Wells, M. (2009). CdSe quantum dots induce superoxide stress in engineered biosensor bacteria. Nanotoxicology 3, 98–108. doi:10.1080/17435390802546089

CrossRef Full Text | Google Scholar

Sharma, P., Asad, S., and Ali, A. (2013). Bioluminescent bioreporter for assessment of arsenic contamination in water samples of India. J. Biosci. 38, 251–258. doi:10.1007/s12038-013-9305-z

PubMed Abstract | CrossRef Full Text | Google Scholar

Shetty, R. S., Deo, S. K., Shah, P., Sun, Y., Rosen, B. P., and Daunert, S. (2003). Luminescence-based whole-cell-sensing systems for cadmium and lead using genetically engineered bacteria. Anal. Bioanal. Chem. 376, 11–17. doi:10.1007/s00216-003-1862-9

PubMed Abstract | CrossRef Full Text | Google Scholar

Shin, H. J. (2011). Genetically engineered microbial biosensors for in situ monitoring of environmental pollution. Appl. Microbiol. Biotechnol. 89, 867–877. doi:10.1007/s00253-010-2990-8

PubMed Abstract | CrossRef Full Text | Google Scholar

Shpigel, E., Shemer, B., Elad, T., Glozman, A., and Belkin, S. (2021). Bacterial bioreporters for the detection of trace explosives: Performance enhancement by DNA shuffling and random mutagenesis. Appl. Microbiol. Biotechnol. 105, 4329–4337. doi:10.1007/s00253-021-11290-2

PubMed Abstract | CrossRef Full Text | Google Scholar

Stenzler, B., Hinz, A., Ruuskanen, M., and Poulain, A. J. (2017). Ionic strength differentially affects the bioavailability of neutral and negatively charged inorganic Hg complexes. Environ. Sci. Technol. 51, 9653–9662. doi:10.1021/acs.est.7b01414

PubMed Abstract | CrossRef Full Text | Google Scholar

Struss, A. K., Pasini, P., and Daunert, S. (2010). in Recognition receptors in Biosensors. Editor M. Zourob (New York, NY: Springer), 565–598.Biosensing systems based on genetically engineered whole cells

CrossRef Full Text | Google Scholar

Su, L., Jia, W., Hou, C., and Lei, Y. (2011). Microbial biosensors: A review. Biosens. Bioelectron. X. 26, 1788–1799. doi:10.1016/j.bios.2010.09.005

CrossRef Full Text | Google Scholar

Sun, Y., Zhao, X., Zhang, D., Ding, A., Chen, C., Huang, W. E., et al. (2017). New naphthalene whole-cell bioreporter for measuring and assessing naphthalene in polycyclic aromatic hydrocarbons contaminated site. Chemosphere 186, 510–518. doi:10.1016/j.chemosphere.2017.08.027

PubMed Abstract | CrossRef Full Text | Google Scholar

Taghavi, K., Fath, P. M., Hosseinkhani, S., Mirzaei, M., Behrooj, H., Kiani, A., et al. (2018). Construction and genetic improvement of copper bioreporter Escherichia coli. Biomed. Biotechnol. Res. J. 2, 26–30. doi:10.4103/bbrj.bbrj_65_17

CrossRef Full Text | Google Scholar

Tang, X., Zhang, T., Liang, B., Han, D., Zeng, L., Zheng, C., et al. (2014). Sensitive electrochemical microbial biosensor for p-nitrophenylorganophosphates based on electrode modified with cell surface-displayed organophosphorus hydrolase and ordered mesopore carbons. Biosens. Bioelectron. X. 60, 137–142. doi:10.1016/j.bios.2014.04.001

PubMed Abstract | CrossRef Full Text | Google Scholar

Tauriainen, S., Karp, M., Chang, W., and Virta, M. (1998). Luminescent bacterial sensor for cadmium and lead. Biosens. Bioelectron. X. 13, 931–938. doi:10.1016/s0956-5663(98)00027-x

PubMed Abstract | CrossRef Full Text | Google Scholar

Turemis, M., Silletti, S., Pezzotti, G., Sanchís, J., Farré, M., and Giardi, M. T. (2018). Optical biosensor based on the microalga-paramecium symbiosis for improved marine monitoring. Sensors Actuators B Chem. 270, 424–432. doi:10.1016/j.snb.2018.04.111

CrossRef Full Text | Google Scholar

Unnikrishnan, B., Lien, C. W., Chu, H. W., and Huang, C. C. (2021). A review on metal nanozyme-based sensing of heavy metal ions: Challenges and future perspectives. J. Hazard. Mat. 401, 123397. doi:10.1016/j.jhazmat.2020.123397

PubMed Abstract | CrossRef Full Text | Google Scholar

Urbano, V. R., Mendonça, T. G., Bastos, R. G., and Souza, C. F. (2017). Effects of treated wastewater irrigation on soil properties and lettuce yield. Agric. Water Manag. 181, 108–115. doi:10.1016/j.agwat.2016.12.001

CrossRef Full Text | Google Scholar

U.S. Environmental Protection Agency (2017). Drinking water contaminants – standards and regulations. Retrieved at: https://www.epa.gov/dwstandardsregulations.

Google Scholar

van der Meer, J. R., Tropel, D., and Jaspers, M. C. M. (2004). Illuminating the detection chain of bacterial bioreporters. Environ. Microbiol. 6, 1005–1020. doi:10.1111/j.1462-2920.2004.00655.x

PubMed Abstract | CrossRef Full Text | Google Scholar

van Genuchten, C. M., Finger, A., van der Meer, J. R., and Pena, J. (2018). Bacterial bioreporter detection of arsenic associated with iron oxides. Environ. Sci. Process. Impacts 20, 913–922. doi:10.1039/c8em00071a

PubMed Abstract | CrossRef Full Text | Google Scholar

Voon, C. H., Yusop, N. M., and Khor, S. M. (2022). The state-of-the-art in bioluminescent whole-cell biosensor technology for detecting various organic compounds in oil and grease content in wastewater: From the lab to the field. Talanta 241, 123271. doi:10.1016/j.talanta.2022.123271

PubMed Abstract | CrossRef Full Text | Google Scholar

Wallenfels, K., and Weil, R. (1972). β-Galactosidase. in The enzymes. Editor P. D. Boyer (New York: Academic Press), 617–663.

CrossRef Full Text | Google Scholar

Wang, G. H., Tsai, T. H., Kui, C. C., Cheng, C. Y., Huang, T. L., and Chung, Y. C. (2021). Analysis of bioavailable toluene by using recombinant luminescent bacterial biosensors with different promoters. J. Biol. Eng. 15, 2. doi:10.1186/s13036-020-00254-1

PubMed Abstract | CrossRef Full Text | Google Scholar

Wang, Q., Edalati, K., Koganemaru, Y., Nakamura, S., Watanabe, M., Ishihara, T., et al. (2020). Photocatalytic hydrogen generation on low-bandgap black zirconia (ZrO2) produced by high-pressure torsion. J. Mat. Chem. A Mat. 8, 3643–3650. doi:10.1039/c9ta11839j

CrossRef Full Text | Google Scholar

Wells, M., Gösch, M., Harms, H., and van der Meer, J. R. (2005c). Response characteristics of arsenic-sensitive bioreporters expressing the gfp reporter gene. Microchim. Acta 151, 209–216. doi:10.1007/s00604-005-0401-0

CrossRef Full Text | Google Scholar

Wells, M., Gösch, M., Rigler, R., Harms, H., Lasser, T., and van der Meer, J. R. (2005b). Ultrasensitive reporter protein detection in genetically engineered bacteria. Anal. Chem. 77, 2683–2689. doi:10.1021/ac048127k

PubMed Abstract | CrossRef Full Text | Google Scholar

Wells, M. (2012). Polycyclic aromatic hydrocarbon (PAH) sensitive bacterial biosensors in environmental health. in Biosensors and environmental health. Editors R. J. Hunter, and V. R. Preedy (New Hampshire: CRC Environmental Health Series, Enfield).

Google Scholar

Wells, M., Wick, L. Y., and Harms, H. (2005a). Model polymer release system study of PAH bioaccessibility: The relationship between “Rapid” release and bioaccessibility. Environ. Sci. Technol. 39, 1055–1063. doi:10.1021/es035067b

PubMed Abstract | CrossRef Full Text | Google Scholar

Who, (2021). A global overview of national regulations and standards for drinking-water quality. Sanitation: WaterHygiene and Health.

Google Scholar

Wilson, T., and Hastings, J. W. (1998). Bioluminescence. Annu. Rev. Cell Dev. Biol. 14, 197–230. doi:10.1146/annurev.cellbio.14.1.197

PubMed Abstract | CrossRef Full Text | Google Scholar

Woutersen, M., Belkin, S., Brouwer, B., van Wezel, A. P., and Heringa, M. B. (2011). Are luminescent bacteria suitable for online detection and monitoring of toxic compounds in drinking water and its sources? Anal. Bioanal. Chem. 400, 915–929. doi:10.1007/s00216-010-4372-6

PubMed Abstract | CrossRef Full Text | Google Scholar

Xu, T. T., Close, D. M., Sayler, G. S., and Ripp, S. (2013). Genetically modified whole-cell bioreporters for environmental assessment. Ecol. Indic. 28, 125–141. doi:10.1016/j.ecolind.2012.01.020

PubMed Abstract | CrossRef Full Text | Google Scholar

Xu, T., Young, A., Marr, E., Sayler, G., Ripp, S., and Close, D. (2018). A rapid and reagent-free bioassay for the detection of dioxin-like compounds and other aryl hydrocarbon receptor (AhR) agonists using autobioluminescent yeast. Anal. Bioanal. Chem. 410, 1247–1256. doi:10.1007/s00216-017-0780-1

PubMed Abstract | CrossRef Full Text | Google Scholar

Xue, P., Zhao, Q., Sun, H., Geng, L., Yang, Z., and Liu, W. (2019). Characteristics of heavy metals in soils and grains of wheat and maize from farmland irrigated with sewage. Environ. Sci. Pollut. Res. 26, 5554–5563. doi:10.1007/s11356-018-3997-4

PubMed Abstract | CrossRef Full Text | Google Scholar

Yagi, K. (2007). Applications of whole-cell bacterial sensors in biotechnology and environmental science. Appl. Microbiol. Biotechnol. 73, 1251–1258. doi:10.1007/s00253-006-0718-6

PubMed Abstract | CrossRef Full Text | Google Scholar

Yoon, Y., Kang, Y., Chae, Y., Kim, S., Lee, Y., Jeong, S. W., et al. (2016). Arsenic bioavailability in soils before and after soil washing: The use of Escherichia coli whole-cell bioreporters. Environ. Sci. Pollut. Res. 23, 2353–2361. doi:10.1007/s11356-015-5457-8

PubMed Abstract | CrossRef Full Text | Google Scholar

Zappi, D., Coronado, E., Basile, G., Varani, G., Turemis, M., Giardi, M. T., et al. (2021). A microbial sensor platform based on bacterial bioluminescence (luxAB) and green fluorescent protein (gfp) reporters for in situ monitoring of toxicity of wastewater nitrification process dynamics. Talanta 221, 121438. doi:10.1016/j.talanta.2020.121438

PubMed Abstract | CrossRef Full Text | Google Scholar

Zeng, N., Wu, Y., Chen, W., Huang, Q., and Cai, P. (2021). Whole-cell microbial bioreporter for soil contaminants detection. Front. Bioeng. Biotechnol. 9, 622994. doi:10.3389/fbioe.2021.622994

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhang, Q., Song, Y., Amor, K., Huang, W. E., Porcelli, D., and Thompson, I. (2019). Monitoring Cr toxicity and remediation processes-combining a whole-cell bioreporter and Cr isotope techniques. Water Res. 153, 295–303. doi:10.1016/j.watres.2019.01.009

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhang, X., Li, B., Deng, J., Qin, B., Wells, M., and Tefsen, B. (2020a). Advances in freshwater risk assessment: Improved accuracy of dissolved organic matter-metal speciation prediction and rapid biological validation. Ecotoxicol. Environ. Saf. 202, 110848. doi:10.1016/j.ecoenv.2020.110848

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhang, X., Li, B., Deng, J., Qin, B., Wells, M., and Tefsen, B. (2020b). Advances in freshwater risk assessment: Improved accuracy of dissolved organic matter-metal speciation prediction and rapid biological validation. Ecotoxicol. Environ. Saf. 202, 110848. doi:10.1016/j.ecoenv.2020.110848

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhang, X., Li, B., Schillereff, D. N., Chiverrell, R. C., Tefsen, B., and Wells, M. (2022b). Whole-cell biosensors for determination of bioavailable pollutants in soils and sediments: Theory and practice. Sci. Total Environ. 811, 152178. doi:10.1016/j.scitotenv.2021.152178

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhang, X., Qin, B., Deng, J., and Wells, M. (2017a). Whole-cell bioreporters and risk assessment of environmental pollution: A proof-of-concept study using lead. Environ. Pollut. 229, 902–910. doi:10.1016/j.envpol.2017.07.068

CrossRef Full Text | Google Scholar

Zhang, X., Zhu, Y., and Wells, M. (2022a). A case study comparing lead-response in different bioreporters: What constitutes a good biosensor? Case Stud. Chem. Environ. Eng. 5, 100192. doi:10.1016/j.cscee.2022.100192

CrossRef Full Text | Google Scholar

Zhang, Y., Boyd, S. A., Teppen, B. J., Tiedje, J. M., and Li, H. (2014). Role of tetracycline speciation in the bioavailability to Escherichia coli for uptake and expression of antibiotic resistance. Environ. Sci. Technol. 48, 4893–4900. doi:10.1021/es5003428

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhang, Z. J., Ju, E. G., Bing, W., Wang, Z. Z., Ren, J. S., and Qu, X. G. (2017b). Chemically individual armoured bioreporter bacteria used for the in vivo sensing of ultra-trace toxic metal ions. Chem. Commun. 53, 8415–8418. doi:10.1039/c7cc03794e

PubMed Abstract | CrossRef Full Text | Google Scholar

Zhao, J., Sun, Y., Zhang, Y., Zhang, B. T., Yin, M., and Chen, L. (2021). Heterogeneous activation of persulfate by activated carbon supported iron for efficient amoxicillin degradation. Environ. Technol. Innov. 21, 101259. doi:10.1016/j.eti.2020.101259

CrossRef Full Text | Google Scholar

Zhou, T., Huang, F., Zhang, C., Li, Z., and Liu, F. (2020). Effects of hydrogeochemical conditions on the distribution of pesticides in the karst river system. Environ. Sci. Pollut. Res. 27, 30468–30478. doi:10.1007/s11356-020-09262-6

PubMed Abstract | CrossRef Full Text | Google Scholar

Zolkefli, N., Sharuddin, S. S., Yusoff, M. Z. M., Hassan, M. A., Maeda, T., and Ramli, N. (2020). A review of current and emerging approaches for water pollution monitoring. Water 12, 3417. doi:10.3390/w12123417

CrossRef Full Text | Google Scholar

Keywords: biosensor, environmental biotechnology, organic pollutant, heavy metal, environmental management, water pollution monitoring

Citation: Zhu Y, Elcin E, Jiang M, Li B, Wang H, Zhang X and Wang Z (2022) Use of whole-cell bioreporters to assess bioavailability of contaminants in aquatic systems. Front. Chem. 10:1018124. doi: 10.3389/fchem.2022.1018124

Received: 12 August 2022; Accepted: 14 September 2022;
Published: 30 September 2022.

Edited by:

Zizhang Guo, Shandong University, China

Reviewed by:

Tingting Xu, The University of Tennessee, Knoxville, United States

Copyright © 2022 Zhu, Elcin, Jiang, Li, Wang, Zhang and Wang. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Xiaokai Zhang, xiaokai.zhang@jiangnan.edu.cn

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.