
94% of researchers rate our articles as excellent or good
Learn more about the work of our research integrity team to safeguard the quality of each article we publish.
Find out more
ORIGINAL RESEARCH article
Front. Bioeng. Biotechnol. , 11 February 2025
Sec. Biomechanics
Volume 13 - 2025 | https://doi.org/10.3389/fbioe.2025.1539976
This article is part of the Research Topic Assessment of Biomechanical Mechanism in the Context of Sports Injury Prevention or Rehabilitation View all 7 articles
Different shapes of carbon-fiber plates (CFPs) are likely to affect lower limb biomechanics, particularly under conditions of running-induced fatigue, and potentially impact runners’ performance and risk of injury. However, no studies have yet elucidated the precise effects of CFP shapes on the lower limb biomechanical characteristics subsequent to running-induced fatigue. The purpose of this study was to investigate the effects of different CFP shapes in running shoes on the lower limb biomechanics of runners following running-induced fatigue. 12 male runners (aged 21.8 ± 1.3 years, mass 59.1 ± 4.1 kg, height 168.9 ± 2.2 cm, weekly running distance 68.8 ± 5.5 km/week) were recruited for this study. Two-way repeated measures ANOVA was used to compare kinematic and kinetic data, while SPM (Statistical Parametric Mapping) was used to assess the activation levels of lower limb muscles. Compared to wearing flat CFP shoes (“Flat”), wearing curved CFP shoes (“Curve”) resulted in a significant reduction in the hip (p = 0.034) and knee contact angle (p < 0.000), as well as a significant decrease in the hip flexion moment (p = 0.008). The activation level of the tibialis anterior (TA) was significantly higher when wearing “Curve” in pre-fatigue compared to “Flat”, whereas the opposite was observed post-fatigue. The curved CFP altered the bending angle of the forefoot, thereby significantly reducing the joint angles and joint moments of the hip and knee.
The popularization and specialization of running led runners to focus more on running shoes, which directly contacted the ground as essential equipment (Bermon, 2021; Lin et al., 2022; Song et al., 2022). Carbon-Fiber Plate Shoes (CPS), designed with lightweight, elastic, and highly cushioned foam midsoles, breathable upper materials, and a rigid carbon-fiber plate (CFP) insert, have been shown to reduce energy consumption during running and enhance running economy (RE) (Worobets et al., 2014; Onodera et al., 2017; Ortega et al., 2021; Subramanium et al., 2021; Gao et al., 2024). The Nike Vaporfly 4% demonstrated a 4% improvement in RE (Hoogkamer et al., 2018), and marathon world record-holder Eliud Kipchoge wore this shoe when he set the record at 2:01:39. This groundbreaking discovery represents a milestone in the development of CPS, driving its increasing popularity in marathon running.
Various variables related to CPS, such as running shoes cushioning (Borgia et al., 2020), stiffness (Rodrigo-Carranza et al., 2022), heel-to-toe drop (Malisoux et al., 2016), and shoes aging (Song et al., 2025; Chambon et al., 2014), have been investigated, but greater emphasis has been placed on the design of the CFP, which has been tailored by designers to meet the individualized requirements of runners for training and competition (Stefanyshyn and Nigg, 2000; Flores et al., 2021; Fu et al., 2021). These design variations include altering plate stiffness (Roy and Stefanyshyn, 2006; Madden et al., 2016), adjusting the plate’s position within the midsole (below, between, or above the midsole) (Stefanyshyn and Nigg, 2000; Madden et al., 2016; Oh and Park, 2017), and modifying the plate’s shape (curved or flat) (Ruiz-Alias et al., 2023). During the stance phase of running, the CFP plays a critical role in influencing the movement of the metatarsophalangeal joint (MTP) (Cigoja et al., 2020; Deschamps et al., 2020; Hoitz et al., 2020; Sun et al., 2020). Compared to lower positions, a higher plate position is associated with a significant reduction in lower limb joint moments and positive knee work, thereby rendering it a preferable configuration for improving running performance (Flores et al., 2021). In terms of plate shape, a review indicated that footwear with a curved CFP improved running economy by 3.45%, while flat CFP footwear provided only a slight improvement of 0.19% (Rodrigo-Carranza et al., 2022). Additionally, research by Song et al. (2024) showed that, compared to flat CFP, curved CFP further reduced forefoot loading during running. These findings demonstrate that CFP design has a significant impact on lower limb biomechanics, with even minor design differences leading to notable variations in effects.
Previous studies have demonstrated that although CPS, particularly those with curved designs, can improve RE to a certain degree, their design may contribute to the acceleration of lower limb fatigue (Agresta et al., 2022; Hata et al., 2022). Fatigue was found to reduce ground contact time and peak knee flexion angle during the stance phase (Morin et al., 2011; Chan-Roper et al., 2012), impair the muscles’ ability to maintain joint stability (Warden et al., 2014; Apte et al., 2021), and lower the symmetry of lower limbs in running gait (Gao et al., 2022). CPS were also shown to cause injuries such as navicular stress fractures and plantar fasciitis in individuals with limited long-distance running experience or those unaccustomed to CFP footwear (McKenzie et al., 1985; Kiuru et al., 2004; Tenforde et al., 2023). Research on the potential performance enhancements provided by CPS and the risks of lower limb injuries linked to running-induced fatigue is continuously advancing. However, studies investigating the effects of varying CFP shapes in running shoes and running-induced fatigue on lower limb biomechanical characteristics have typically treated these factors independently. No study has yet examined how the combined effects of CFP shape and running-induced fatigue in shoes with embedded carbon plates impact lower limb biomechanical characteristics, running performance, and the risk of running-related injuries. Therefore, the purpose of this study was to investigate the effects of different CFP shapes in running shoes on the lower limb biomechanics of runners following running-induced fatigue. Based on previous studies, it was hypothesized that variations in CFP shapes would influence the distance between the cushioning foam material and the ground, resulting in reduced ground impact at the MTP during initial contact for runners wearing curved CPS as opposed to flat CPS. Furthermore, irrespective of fatigue, curved CPS exhibited superior performance compared to flat CPS. We speculated that the curved CPS would facilitate better leverage at the MTP, thereby increasing its range of motion (ROM) and positive work. Additionally, to cope with varying impacts and stabilize the lower limb joints, the activation levels of the calf muscles would exhibit differences.
This study will compare the differences in lower limb kinematics, dynamics, and muscle activation characteristics before and after running-induced fatigue, using running shoes with different CFP shapes. The impact of CFP shape on lower limb fatigue patterns will be assessed, providing data to support improvements in running performance and injury prevention. The study will reveal the influence of CFP and fatigue status on performance and injury risk, offering scientific evidence for the design of sports footwear and assisting designers in developing running shoes that are more aligned with biomechanical principles.
An effect size of 0.78 was calculated from the results of the preliminary experiment. To enhance the robustness of the experimental results, the effect size was adjusted to 0.70. According to the result from G-power 3.1 (x64, Heinrich Heine University Düsseldorf, Germany), the minimum sample size required for this study was determined to be 10 participants (with (1-β) = 0.95, significance level α = 0.05, two groups, and two measurements). Therefore, this study recruited 12 male young runners at the elite level or above as participants. Therefore, we recruited 12 male mass elite runners (aged 21.8 ± 1.3 years, mass 59.1 ± 4.1 kg, height 168.9 ± 2.2 cm, weekly running distance 68.8 ± 5.5 km/week, personal best of half marathon 78.75 ± 2.27 min, Personal best of half marathon full marathon 175.28 ± 3.51 min, as participants through personal contacts and Ningbo Marathon Association. Among the participants, 10 habitually employ a forefoot strike, while two employ a rearfoot strike. All runners selected to participate in this experiment meet the following criteria: fitting 41 EU size shoes, the dominant leg is right leg, the best personal record for the half marathon is sub-85 min (or equivalent) and/or for the full marathon is sub-180 min (or equivalent) based on the 2024 classification standards for mass participants issued by the Chinese Athletics Association (RunChina, 2024), and free from any injuries sustained in the lower limbs in the past 6 months. Written informed consent was provided by all participants for the experimental procedures, which were approved by the Ningbo University Ethics Committee (TY2024210). This study was compiled with the Declaration of Helsinki.
Two types of running shoes were employed in this study: ASICS METASPEED SKY PARIS and ASICS METASPEED EDGE PARIS. Both experimental shoe models exhibit a similar appearance, featuring FF (Flyte Foam) Turbo Plus as the midsole material and a rigid embedded CFP. The difference is that the former weighs 183 g/shoe and has a flatter CFP, hence abbreviated as “Flat”, while the latter weighs 185 g/shoe and features a more curved carbon plate at the forefoot, hence abbreviated as “Curve”. To eliminate differences in shoe weight, a 2 g muscle-effect patch was applied to the “Flat” to balance the mass. In addition, manual measurements revealed that the “Curve” exhibits a toe box 3 mm higher than that of the “Flat.” The total running distance for any pair of shoes was limited to no more than 50 km (Figure 1).
Figure 1. Image of the shoes prototype utilized in the experiment. The upper shows the exterior view of the shoes, while the lower displays the internal CFP captured. (A) Is the “Flat”, and (B) is the “Curve”.
Each participant was required to complete two laboratory visits as part of this study. The procedures were common on both visits, with the only difference being that participants randomly wore one pair of shoes on Visit1 and wore the other pair on Visit2. The randomization process primarily involved ensuring that participants were unaware of the specific differences between the two pairs of experimental shoes both before and during the experiment. The order of shoe wear for the two experimental sessions was determined according to the participants’ subjective preferences, thereby achieving randomization in this study. The flowchart of experiment as shown in Figure 2.
Participants performed a 10-min running warm-up at a self-selected speed in their own shoes on a treadmill (Saturn 300/100 r, h/p/cosmos, Germany). Following a 5-min cool-down, the anatomical positions of the right tibialis anterior (TA), medial gastrocnemius (MG), and lateral gastrocnemius (LG) were identified for electromyography (EMG) electrode placement (Delsys, Natick, MA, United States). Before the placement of the electrodes, the hair was wiped off with a razor and cleaned with an alcohol wipe. To facilitate motion capture, a total of 38 reflective markers were attached to anatomical landmarks according to the 2,392 model (Delp et al., 1990). The placement locations of reflective markers and EMG electrodes are illustrated in Figure 3.
The fatigue intervention began with a treadmill set to a 1° incline to simulate an outdoor running environment (Fourchet et al., 2015). Participants began walking on a treadmill at a speed of 6 km/h, with the speed increasing by 1 km/h every 2 min, enabling them to transition into running. Heart rate (HR) data were collected using Polar heart rate monitors (Polar Electro, Kempele, Finland), and RPE (Rate of Perceived Exertion) scores were responded by the participants every minute throughout the intervention. The RPE score is a rating method used to measure an individual’s subjective perception of effort during exercise or physical activity, ranging from 6 (almost no effort) to 20 (maximum effort). The treadmill speed stabilized when participants’ RPE scores reached 13 (indicating slight fatigue). Participants then continued running at this steady speed until their heart rate (HR) reached 85% of their maximum heart rate (calculated as 220 minus age) and maintained this level for 2 min without significant decline, completing the fatigue protocol (Hajiloo et al., 2020). Markers and EMG electrodes often dislodged during the fatigue intervention due to sweating and movement, therefore, to reduce the preparation time after the intervention, a black marker pen was used to mark the center locations of the markers on the skin before the formal experiment.
Data collection began with a static calibration trial, which was subsequently used to scale a musculoskeletal model. The participants along an 18-m track at a self-selected speed. A 3D motion capture system with 10 cameras (Vicon Metrics Ltd., Oxford, United Kingdom) and 2 force plates (Kistler, Winterthur, Switzerland) recorded marker trajectories and ground reaction forces (GRF) during running at sampling frequencies of 200 Hz and 2000 Hz, respectively and Delsys recorded EMG signals synchronously at a sampling frequency of 2000 Hz. A successful test was defined as the dominant leg fully landed on the force plate.
Once the pre-fatigue data collection was completed, the fatigue intervention was carried out. After the fatigue intervention, any dropped markers and EMG electrodes were replaced, and the data collection process was repeated following the same procedures as pre-fatigue. To minimize measurement errors and enhance data accuracy, three successful data sets were collected during each test. Following the completion of Visit 1, a 48-h washout period was implemented before the commencement of Visit 2 (Ruiz-Alias et al., 2024).
The kinematic data of right hip, knee, ankle, and MTP during the stance phase, as well as GRF, were collected as participants passed through the force plates. Vicon Nexus (2.15.0 x64, Vicon Motion Systems, Oxford, United Kingdom) was used to preprocess the kinematic data, with a vertical GRF threshold of 10N set for stance phase detection, resulting in c3d. files. The custom code in MATLAB (R2022a, The MathWorks Inc., Natick, Middlesex, MA, United States) was used to convert the files. The angle and the moments of the hip, the knee, the ankle and the MTP joints of the right lower limb were calculated in the sagittal plane during the stance phase using the inverse kinematics and inverse dynamics algorithm tools in OpenSim 4.3. Custom Python code was employed to filter the kinematic data at 6 Hz, while the GRF data were low-pass filtered at 50 Hz with a critically damped filter. In the presentation of lower limb biomechanical parameters such as joint angles and joint moments, positive values represent hip flexion, knee extension, and dorsiflexion of the ankle and MTP, while negative values represent hip extension, knee flexion, and plantarflexion of the ankle and MTP. Based on previous research, the vertical average loading rate (VALR) was considered as a representative value of the loading rate (LR) of the GRF (Willson et al., 2014). The VALR is the slope of the line connecting the 20% point and the 80% point of the 13% stance phase (An et al., 2015). Joint power is determined using the following equation:
P represents the joint power (units: W/kg), M denotes the joint moment (units: Nm), ω denotes the joint angle velocity (units: rad/s).
The work performed by the joint is determined using the following equation:
W represents the work performed by the joint (units: J/kg), P denotes the joint power, t1 and t2 denote the start and end times of the integration interval.
EMG data were filtered using a band-pass filter between 20 and 450 Hz. To perform the linear envelope process, the EMG data were full-wave rectified and subsequently low-pass filtered at a cutoff frequency of 20 Hz using a fourth-order Butterworth filter. The submaximal method was used for normalization, where the maximum EMG signal for each muscle was first calculated under each of the conditions in our study, and each data point was then divided by the maximum value for the corresponding condition to obtain the muscle activation as a percentage of the maximum muscle activity for that condition (Hajiloo et al., 2020). The collected EMG signals were time-normalized and divided into 101 points.
The statistical analyses were performed by SPSS (26, IBM Corp., Armonk, NY, United States), and the obtained parameters are expressed as mean ± standard deviation (X±SD), the Shapiro-Wilk test was employed. A two-way repeated measures ANOVA was used to evaluate the main effects of “CFP shape” and “fatigue,” as well as the interaction between these factors on biomechanical variables. Alpha levels were set at 0.05. When the interaction effect was significant, post hoc pairwise comparisons were conducted, and the alpha level was adjusted to <0.0125 using the Bonferroni correction.
A Statistical Parametric Mapping (SPM) procedure (Pataky et al., 2013) was used to assess the main effects of “CFP shape” and “fatigue”, as well as their interaction, on the EMG signals of the TA and gastrocnemius muscles during the stance phase of running. SPM tests were calculated using SPM1d v0.4 for MATLAB (Pataky et al., 2015). The significance level for all statistical tests was set at 0.05.
The results showed that the interaction between “CFP shape” and “fatigue” had significant effect on the ROM of the knee (p = 0.014) and ankle (p = 0.036), the flexion moment of hip (p = 0.025), dorsiflexion moment of ankle (p = 0.05) (Table 2; Figure 4), ankle negative work (p = 0.036), dorsiflexion power of MTP (p = 0.017) and positive work (p = 0.018) (Table 3). It also significantly affected the activation level of the TA during 80%–100% of the stance phase (p < 0.001) (Figure 5). Post-hoc tests revealed that the interaction between CFP shape and fatigue had a significant effect only on the activation of the TA.
Figure 4. Joint angle (top column) and joint moment (bottom column) for the hip, knee, ankle, and MTP. Red indicates wearing “Flat”, black indicates wearing “Curve”; solid lines represent pre-fatigue, and dashed lines represent post-fatigue.
Figure 5. Activation levels of the TA, MG, and LG. Red indicates wearing “Flat”, black indicates wearing “Curve”; solid lines represent pre-fatigue, and dashed lines represent post-fatigue. The significant main effects of the interaction, the shape and the fatigue are highlighted (black horizontal bars at the bottom of the figure) during corresponding time periods.
The significant effects of CFP shape on biomechanical parameters were observed in the contact angle of hip (p = 0.034), knee (p < 0.000), and average flexion moment of hip (p = 0.010) (Table 1; Table 2; Figure 4). Compared to wearing “Flat”, wearing “Curve” resulted in a significant reduction in the contact angle of knee and hip, and average flexion moment of hip in pre- and post-fatigue. The significant effects of fatigue were found in the average flexion moment of hip (p = 0.008) and contact moment of knee (p = 0.018) (Table 1; Table 2; Figure 4). Compared to pre-fatigue, the average flexion moment of hip was significantly reduced in post-fatigue when wearing both types of CPS. There were no significant differences in power and work for the ankle joint and MTP (Table 3).
Table 1. VALR (BW/s), joints contact angle (°) and contact moment (Nm/kg) of the hip, knee, ankle, and MTP (Mean ± SD).
In addition, at different stages of the stance phase, either CFP shape or fatigue had significant effects on the activation levels of the TA, MG, and LG. From 0% to 30%, the activation level of the TA was higher when wearing “Curve” compared to “Flat”. From 10% to 30%, the activation of the MG was higher when wearing “Curve”, while from 40% to 90%, MG activation was higher when wearing “Flat”. For the LG, activation was higher in “Flat” than in “Curve” during 45%–100% of the stance phase. Regarding the effect of fatigue, from 15% to 42%, TA activation was higher in post-fatigue compared to pre-fatigue. From 5% to 48%, LG activation was significantly higher in post-fatigue than pre-fatigue. Between 40% and 68%, fatigue had a significant effect on MG activation (Figure 5).
This study compared the differences in lower extremity kinematics, kinetics, and muscle activation levels before and after fatigue in 12 male recreationally elite marathon runners who wore two different carbon-plated running shoes. Previous research has demonstrated that these biomechanical indicators are associated with marathon runners’ performance and the risk of running-related injuries. While previous studies have examined the effects of variations in the carbon plate embedded in different running shoes on running performance, the combined effects of carbon plate shape and running fatigue on lower extremity biomechanical characteristics remain unclear. Therefore, the purpose of this study was to investigate the effects of different CFP shapes in running shoes on the lower limb biomechanical characteristics following running-induced fatigue. The main results indicated that, compared to “Flat”, wearing “Curve” resulted in a decrease in the hip and knee contact angles and a reduction in the hip flexion moment. However, there were no significant effects on power and work of joints, which contradicted our hypothesis. In terms of muscle activation, the interaction between CFP and fatigue significantly affected the activation of the TA. Pre-fatigue, the activation level of the TA was higher when wearing “Curve” than when wearing “Flat”, while the opposite was true following running-induced fatigue. This study will examine the impact of different carbon plate shapes in running shoes on lower extremity biomechanical characteristics before and after running fatigue, thereby providing data to support performance enhancement and injury prevention in runners.
The VALR have been retrospectively associated with various running-related overuse injuries. The VALR was selected as an evaluation metric to compare ground impact under varying conditions; however, the results did not indicate significant differences, contradicting our hypothesis (Table 1). In Lieberman’s study, compared to shod running, barefoot running reduced VALR by adjusting the landing pattern (Lieberman et al., 2010). Furthermore, Cheung compared VALR while running on a treadmill with different inclines, both shod and barefoot, and found differences in results, but these were not due to the presence or barefoot, but rather because the landing pattern had changed (An et al., 2015). Compared to footwear properties, changes in VALR may be more strongly influenced by landing patterns. Upon observation, it was found that the landing patterns of the runners in this study did not change under different conditions. The results aligned with previous studies, thus explaining the lack of significant differences in the VALR.
Cigoja et al. (2021) compared the biomechanical data of “Curve” with “Flat” from other experiments (Hoogkamer et al., 2019; Hunter et al., 2019), including stance time, ankle and MTP work, angular velocity, and angles, and found comparable results. However, in our experimental results, there were significant differences in joint angles and moments at the hip and knee joints between the two CFP shapes. Our results showed that, compared to “Flat”, wearing “Curve” significantly reduced the hip contact angle (p = 0.034) and knee contact angle (p < 0.000) (Table 1). In the comparison by Zhou et al. (2021) between high-cushioned bionic shoes and normal shoes, it was found that using bionic shoes caused greater knee and hip flexion than normal shoes. The flexion moment at the hip joint was significantly lower when wearing “Curve” in pre- and post-fatigue than with “Flat” (p = 0.010) (Table 2; Figure 4). Under both CFP conditions, the knee joint contact moment in pre-fatigue was significantly lower than post-fatigue (p = 0.018) (Table 1), while no significant differences were observed in other lower limb joint moments. The research indicates that stiffer shoes can increase hip joint moments (Bergmann et al., 1995), potentially leading to hip joint injuries. Footwear can alter the forces applied by muscles on the lower limb joints and may reduce injury risk by alleviating loads on the joints (Chughtai et al., 2018). The CFP in running shoes is designed to enhance running efficiency by mimicking the principles of levers (Roy and Stefanyshyn, 2006). The significant changes observed in hip and knee joint moments and ground contact angles when wearing “Flat” may result from coupling between the MTP and ankle joint movements with other lower limb joints during the propulsion phase (Allan et al., 2020; Miyazaki et al., 2024), which may explain how different CFP shapes can alter the bending angle of the forefoot and subsequently affect gait parameters.
It has been proposed that muscle activation patterns played an important role in the underlying principles that governed a runner’s preferred movement path (Nigg et al., 2017). Later, Hoitz et al. (2020) indicated that when there were significant kinematic differences due to shoe structures (a minimalist, a conventionally cushioned, and a racing flat shoe), muscle activation strategies changed. Nigg et al. (2021) suggested that the embedded “Curve” in running shoes could be seen as a “lever.” When a runner applies force to the forefoot, the pivot point of the plate shifts forward, causing the center of pressure to move forward as well, thus generating a reaction force at the heel. In our study using SPM to investigate muscle activation (Figure 5), we found that the interaction between CFP shape and fatigue significantly influenced TA activation levels only during 80%–100% of the stance phase. Interestingly, during this phase, the activation level of the TA post-fatigue while wearing the “Flat” condition was higher than that observed pre-fatigue, whereas the activation levels pre- and post-fatigue with the “Curve” condition showed the opposite pattern. The reduction in knee joint contact angle and hip joint flexion moment while wearing the “Curve” condition, as compared to the “Flat” condition, required adjustments in the muscle activation strategy of the TA to stabilize movement. Regarding the influence of CFP shape, the peak activation of the MG and LG muscles occurred later and was greater when wearing “Flat” than when wearing “Curve”. This result may be explained by the lever effect of the curved CFP (Nigg et al., 2021). The incorporation of the curved CFP facilitated increased cushioning space in the midsole, thereby enabling a larger ROM in the MTP and reducing the engagement of the hip, knee, and ankle joints. In contrast, flat CFPs were unable to leverage this effect at the forefoot position, requiring greater activation from the lower limb muscles during the later stance phase. Additionally, the reduced height of the cushioning midsole between the flat CFP and the foot led to higher activation levels in the gastrocnemius, owing to the harder impact of the CFP (Kiesewetter et al., 2022). In a study comparing the effects of barefoot running and wearing CPS on muscle activity, Beck et al. (2020) found that increased longitudinal bending stiffness in shoes did not affect muscle activity during running. Similarly, a study on the impact of shoe hardness on lower limb muscle activity found that soft, medium, and hard midsoles did not influence the activity of the medial quadriceps, biceps femoris, and gastrocnemius (Nigg and Gérin-Lajoie, 2011). This suggests that the differences in lower limb muscle activation levels may have resulted from the influence of CFP on the bending angle of the forefoot.
Interpretations of this study should take the following limitations into account. First, we did not conduct stiffness testing on the running shoes. Although the foam midsoles and CFP were made of the same material but had different shapes, which may affect midsole stiffness (Flores et al., 2019), we did not rule out the potential influence of shoe stiffness on the experimental results. Second, using only VALR as a measure of impact is somewhat limited. Future research could incorporate plantar pressure measurements to assess the impact of CFP on the foot, thereby evaluating injury risk (Willwacher et al., 2022). Lastly, inconsistent with our hypothesis, there was no significant difference observed at the MTP, which may be due to our insufficient precision in studying the MTP. Future studies could improve precision in capturing MTP movement by affixing reflective markers through holes in the shoes (Zhu et al., 2024) to better analyze the effects of carbon plate shape on the MTP.
Different CFP shapes and running-induced fatigue have a significant impact on lower limb biomechanics. Compared to wearing “Flat,” wearing “Curve” resulted in a significant reduction in the contact angle of the knee and hip, as well as the average flexion moment of the hip in pre- and post-fatigue. Compared to pre-fatigue, the average flexion moment of the hip was significantly reduced post-fatigue when wearing both types of two CPS. The interaction affected the activation level of the TA during 80%–100% of the stance phase. Overall, the curved CFP altered the bending angle of the forefoot, thereby significantly reducing the joint angles and joint moments of the hip and knee. In summary, running shoes incorporating curved carbon plates demonstrate greater potential in enhancing running performance and reducing the risk of running-related injuries. In the future, additional variations of curved carbon plate running shoes could be incorporated, and female recreational elite runners could be included as research participants, thereby enhancing the generalizability of the results.
The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.
The studies involving humans were approved by Ningbo university ethics committee (TY2024210). The studies were conducted in accordance with the local legislation and institutional requirements. The participants provided their written informed consent to participate in this study.
YX: Investigation, Methodology, Validation, Writing–original draft. CZ: Data curation, Investigation, Methodology, Writing–original draft. YF: Formal Analysis, Methodology, Writing–review and editing. ZL: Conceptualization, Writing–review and editing. YS: Methodology, Writing–review and editing. CH: Conceptualization, Data curation, Investigation, Writing–review and editing. DS: Conceptualization, Investigation, Resources, Supervision, Writing–review and editing. YG: Funding acquisition, Investigation, Resources, Supervision, Writing–review and editing.
The author(s) declare that financial support was received for the research, authorship, and/or publication of this article. This study was sponsored by the Zhejiang Provincial Natural Science Foundation of China for Distinguished Young Scholars (LR22A020002), Zhejiang Provincial Natural Science Foundation (LTGY23H040003), Zhejiang Rehabilitation Medical Association Scientific Research Special Fund (ZKKY2024012), Ningbo NO. 2 Hospital Huamei Research Fund (2024HMKYA53), Ningbo key R&D Program (2022Z196), Research Academy of Medicine Com-bining Sports, Ningbo (No. 2023001), the Project of NINGBO Leading Medical &Health Discipline (No. 2022-F15, No. 2022-F22), Ningbo Natural Science Foundation (2022J065, 20221JCGY010607), Public Welfare Science & Technology Project of Ningbo, China (2021S134), and Zhejiang Reha-bilitation Medical Association Scientific Research Special Fund (ZKKY2023001).
We would like to express our gratitude to all those who took part in this study, as well as those who provided invaluable guidance and support.
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
The reviewer FY declared a past co-authorship with the author(s) YG to the handling editor.
The authors declare that no Generative AI was used in the creation of this manuscript.
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
Agresta, C., Giacomazzi, C., Harrast, M., and Zendler, J. (2022). Running injury paradigms and their influence on footwear design features and runner assessment methods: a focused review to advance evidence-based practice for running medicine clinicians. Front. Sports Act. Living 4, 815675. doi:10.3389/fspor.2022.815675
Allan, J. J., McClelland, J. A., Munteanu, S. E., Buldt, A. K., Landorf, K. B., Roddy, E., et al. (2020). First metatarsophalangeal joint range of motion is associated with lower limb kinematics in individuals with first metatarsophalangeal joint osteoarthritis. J. Foot Ankle Res. 13, 33. doi:10.1186/s13047-020-00404-0
An, W., Rainbow, M. J., and Cheung, R. T. H. (2015). Effects of surface inclination on the vertical loading rates and landing pattern during the first attempt of barefoot running in habitual shod runners. Biomed. Res. Int. 2015, 1–7. doi:10.1155/2015/240153
Apte, S., Prigent, G., Stöggl, T., Martínez, A., Snyder, C., Gremeaux-Bader, V., et al. (2021). Biomechanical response of the lower extremity to running-induced acute fatigue: a systematic review. Front. Physiol. 12, 646042. doi:10.3389/fphys.2021.646042
Beck, O. N., Golyski, P. R., and Sawicki, G. S. (2020). Adding carbon fiber to shoe soles may not improve running economy: a muscle-level explanation. Sci. Rep. 10, 17154. doi:10.1038/s41598-020-74097-7
Bergmann, G., Kniggendorf, H., Graichen, F., and Rohlmann, A. (1995). Influence of shoes and heel strike on the loading of the hip joint. J. Biomech. 28, 817–827. doi:10.1016/0021-9290(94)00129-R
Bermon, S. (2021). Evolution of distance running shoes: performance, injuries, and rules. J. Sports Med. Phys. Fit. 61, 1073–1080. doi:10.23736/S0022-4707.21.12728-8
Borgia, B., Freedman Silvernail, J., and Becker, J. (2020). Joint coordination when running in minimalist, neutral, and ultra-cushioning shoes. J. Sports Sci. 38, 855–862. doi:10.1080/02640414.2020.1736245
Chambon, N., Sevrez, V., Ly, Q. H., Guéguen, N., Berton, E., and Rao, G. (2014). Aging of running shoes and its effect on mechanical and biomechanical variables: implications for runners. J. Sports Sci. 32, 1013–1022. doi:10.1080/02640414.2014.886127
Chan-Roper, M., Hunter, I., W Myrer, J., L Eggett, D., and K Seeley, M. (2012). Kinematic changes during a marathon for fast and slow runners. J. Sports Sci. Med. 11, 77–82.
Chughtai, M., Newman, J. M., Akil, S., Khlopas, A., Sultan, A. A., Sodhi, N., et al. (2018). Knee pain and the use of various types of footwear—a review. J. Knee Surg. 31, 952–964. doi:10.1055/s-0038-1626735
Cigoja, S., Asmussen, M. J., Firminger, C. R., Fletcher, J. R., Edwards, W. B., and Nigg, B. M. (2020). The effects of increased midsole bending stiffness of sport shoes on muscle-tendon unit shortening and shortening velocity: a randomised crossover trial in recreational male runners. Sports Med. Open 6, 9. doi:10.1186/s40798-020-0241-9
Cigoja, S., Fletcher, J. R., Esposito, M., Stefanyshyn, D. J., and Nigg, B. M. (2021). Increasing the midsole bending stiffness of shoes alters gastrocnemius medialis muscle function during running. Sci. Rep. 11, 749. doi:10.1038/s41598-020-80791-3
Delp, S. L., Loan, J. P., Hoy, M. G., Zajac, F. E., Topp, E. L., and Rosen, J. M. (1990). An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures. IEEE Trans. Biomed. Eng. 37, 757–767. doi:10.1109/10.102791
Deschamps, K., Matricali, G., Peters, H., Eerdekens, M., Wuite, S., Leardini, A., et al. (2020). Contribution of foot joints in the energetics of human running. Comput. Methods Biomech. Biomed. Engin. 23, 557–563. doi:10.1080/10255842.2020.1746287
Flores, N., Delattre, N., Berton, E., and Rao, G. (2019). Does an increase in energy return and/or longitudinal bending stiffness shoe features reduce the energetic cost of running? Eur. J. Appl. Physiol. 119, 429–439. doi:10.1007/s00421-018-4038-1
Flores, N., Rao, G., Berton, E., and Delattre, N. (2021). The stiff plate location into the shoe influences the running biomechanics. Sports Biomech. 20, 815–830. doi:10.1080/14763141.2019.1607541
Fourchet, F., Girard, O., Kelly, L., Horobeanu, C., and Millet, G. P. (2015). Changes in leg spring behaviour, plantar loading and foot mobility magnitude induced by an exhaustive treadmill run in adolescent middle-distance runners. J. Sci. Med. Sport 18, 199–203. doi:10.1016/j.jsams.2014.01.007
Fu, F., Levadnyi, I., Wang, J., Xie, Z., Fekete, G., Cai, Y., et al. (2021). Effect of the construction of carbon Fiber Plate insert to midsole on running performance. Mater. Basel Switz. 14, 5156. doi:10.3390/ma14185156
Gao, S., Song, Y., Sun, D., Zheng, Z., Chen, H., Zhang, Q., et al. (2024). The impact of running experience and shoe longitudinal bending stiffness on lower extremity biomechanics: a cross-sectional study. Acta Bioeng. Biomechanics 26 (2), 93–103. doi:10.37190/ABB-02461-2024-03
Gao, Z., Fekete, G., Baker, J. S., Liang, M., Xuan, R., and Gu, Y. (2022). Effects of running fatigue on lower extremity symmetry among amateur runners: from a biomechanical perspective. Front. Physiol. 13, 899818. doi:10.3389/fphys.2022.899818
Hajiloo, B., Anbarian, M., Esmaeili, H., and Mirzapour, M. (2020). The effects of fatigue on synergy of selected lower limb muscles during running. J. Biomech. 103, 109692. doi:10.1016/j.jbiomech.2020.109692
Hata, K., Noro, H., Takeshita, T., Yamazaki, Y., and Yanagiya, T. (2022). Leg stiffness during running in highly cushioned shoes with a carbon-fiber plate and traditional shoes. Gait Posture 95, 9–14. doi:10.1016/j.gaitpost.2022.03.021
Hoitz, F., Vienneau, J., and Nigg, B. M. (2020). Influence of running shoes on muscle activity. PLOS ONE 15, e0239852. doi:10.1371/journal.pone.0239852
Hoogkamer, W., Kipp, S., Frank, J. H., Farina, E. M., Luo, G., and Kram, R. (2018). A comparison of the energetic cost of running in marathon racing shoes. Sports Med. 48, 1009–1019. doi:10.1007/s40279-017-0811-2
Hoogkamer, W., Kipp, S., and Kram, R. (2019). The biomechanics of competitive male runners in three marathon racing shoes: a randomized crossover study. Sports Med. 49, 133–143. doi:10.1007/s40279-018-1024-z
Hunter, I., McLeod, A., Valentine, D., Low, T., Ward, J., and Hager, R. (2019). Running economy, mechanics, and marathon racing shoes. J. Sports Sci. 37, 2367–2373. doi:10.1080/02640414.2019.1633837
Kiesewetter, P., Bräuer, S., Haase, R., Nitzsche, N., Mitschke, C., and Milani, T. L. (2022). Do carbon-plated running shoes with different characteristics influence physiological and biomechanical variables during a 10 km treadmill run? Appl. Sci. 12, 7949. doi:10.3390/app12157949
Kiuru, M. J., Pihlajamäki, H. K., and Ahovuo, J. A. (2004). Bone stress injuries. Acta Radiol. 45, 000–326. doi:10.1080/02841850410004724
Lieberman, D. E., Venkadesan, M., Werbel, W. A., Daoud, A. I., D’Andrea, S., Davis, I. S., et al. (2010). Foot strike patterns and collision forces in habitually barefoot versus shod runners. Nature 463, 531–535. doi:10.1038/nature08723
Lin, S., Song, Y., Cen, X., Bálint, K., Fekete, G., and Sun, D. (2022). The implications of sports biomechanics studies on the research and development of running shoes: a systematic review. Bioengineering 9 (10), 497. doi:10.3390/bioengineering9100497
Madden, R., Sakaguchi, M., Tomaras, E. K., Wannop, J. W., and Stefanyshyn, D. (2016). Forefoot bending stiffness, running economy and kinematics during overground running. Footwear Sci. 8, 91–98. doi:10.1080/19424280.2015.1130754
Malisoux, L., Chambon, N., Urhausen, A., and Theisen, D. (2016). Influence of the heel-to-toe drop of standard cushioned running shoes on injury risk in leisure-time runners: a randomized controlled trial with 6-month follow-up. Am. J. Sports Med. 44, 2933–2940. doi:10.1177/0363546516654690
McKenzie, D. C., Clement, D. B., and Taunton, J. E. (1985). Running shoes, orthotics, and injuries. Sports Med. 2, 334–347. doi:10.2165/00007256-198502050-00003
Miyazaki, T., Aimi, T., Yamada, Y., and Nakamura, Y. (2024). Curved carbon plates inside running shoes modified foot and shank angular velocity improving mechanical efficiency at the ankle joint. J. Biomech. 172, 112224. doi:10.1016/j.jbiomech.2024.112224
Morin, J.-B., Samozino, P., and Millet, G. Y. (2011). Changes in running kinematics, kinetics, and spring-mass behavior over a 24-h run. Med. Sci. Sports Exerc. 43, 829–836. doi:10.1249/MSS.0b013e3181fec518
Nigg, B. M., Cigoja, S., and Nigg, S. R. (2021). Teeter-totter effect: a new mechanism to understand shoe-related improvements in long-distance running. Br. J. Sports Med. 55, 462–463. doi:10.1136/bjsports-2020-102550
Nigg, B. M., and Gérin-Lajoie, M. (2011). Gender, age and midsole hardness effects on lower extremity muscle activity during running. Footwear Sci. 3, 3–12. doi:10.1080/19424280.2010.536586
Nigg, B. M., Vienneau, J., Smith, A. C., Trudeau, M. B., Mohr, M., and Nigg, S. R. (2017). The preferred movement path paradigm: influence of running shoes on joint movement. Med. Sci. Sports Exerc. 49, 1641–1648. doi:10.1249/MSS.0000000000001260
Oh, K., and Park, S. (2017). The bending stiffness of shoes is beneficial to running energetics if it does not disturb the natural MTP joint flexion. J. Biomech. 53, 127–135. doi:10.1016/j.jbiomech.2017.01.014
Onodera, A. N., Gavião Neto, W. P., Roveri, M. I., Oliveira, W. R., and Sacco, I. C. (2017). Immediate effects of EVA midsole resilience and upper shoe structure on running biomechanics: a machine learning approach. PeerJ 5, e3026. doi:10.7717/peerj.3026
Ortega, J. A., Healey, L. A., Swinnen, W., and Hoogkamer, W. (2021). Energetics and biomechanics of running footwear with increased longitudinal bending stiffness: a narrative review. Sports Med. 51, 873–894. doi:10.1007/s40279-020-01406-5
Pataky, T. C., Robinson, M. A., and Vanrenterghem, J. (2013). Vector field statistical analysis of kinematic and force trajectories. J. Biomech. 46, 2394–2401. doi:10.1016/j.jbiomech.2013.07.031
Pataky, T. C., Vanrenterghem, J., and Robinson, M. A. (2015). Zero-vs. one-dimensional, parametric vs. non-parametric, and confidence interval vs. hypothesis testing procedures in one-dimensional biomechanical trajectory analysis. J. Biomech. 48, 1277–1285. doi:10.1016/j.jbiomech.2015.02.051
Rodrigo-Carranza, V., González-Mohíno, F., Santos-Concejero, J., and González-Ravé, J. M. (2022). The effects of footwear midsole longitudinal bending stiffness on running economy and ground contact biomechanics: a systematic review and meta-analysis. Eur. J. Sport Sci. 22, 1508–1521. doi:10.1080/17461391.2021.1955014
Roy, J.-P. R., and Stefanyshyn, D. J. (2006). Shoe midsole longitudinal bending stiffness and running economy, joint energy, and EMG. Med. Sci. Sports Exerc. 38, 562–569. doi:10.1249/01.mss.0000193562.22001.e8
Ruiz-Alias, S. A., Molina-Molina, A., Soto-Hermoso, V. M., and García-Pinillos, F. (2023). A systematic review of the effect of running shoes on running economy, performance and biomechanics: analysis by brand and model. Sports Biomech. 22, 388–409. doi:10.1080/14763141.2022.2089589
Ruiz-Alias, S. A., Pérez-Castilla, A., Soto-Hermoso, V. M., and García-Pinillos, F. (2024). Influence of the carbon fiber plate curvature of advanced footwear technology on the running energetic cost and 3000-m performance. Sports Eng. 27, 21. doi:10.1007/s12283-024-00465-5
RunChina (2024). The official website of China Marathon. Available at: https://www.runchina.org.cn/#/news/official-news/detail/XW202446008 (Accessed January 6, 2025).
Song, Y., Cen, X., Sun, D., Bálint, K., Wang, Y., Chen, H., et al. (2024). Curved carbon-plated shoe may further reduce forefoot loads compared to flat plate during running. Sci. Rep. 14, 13215. doi:10.1038/s41598-024-64177-3
Song, Y., Cen, X., Wang, M., Bálint, K., Tan, Q., Sun, D., et al. (2025). The influence of simulated worn shoe and foot inversion on heel internal biomechanics during running impact: a subject-specific finite element analysis. J. Biomechanics 180, 112517. doi:10.1016/j.jbiomech.2025.112517
Song, Y., Shao, E., Bíró, I., Baker, J. S., and Gu, Y. (2022). Finite element modelling for footwear design and evaluation: a systematic scoping review. Heliyon 8 (10), e10940. doi:10.1016/j.heliyon.2022.e10940
Stefanyshyn, D. J., and Nigg, B. M. (2000). Influence of midsole bending stiffness on joint energy and jump height performance. Med. Sci. Sports Exerc. 32, 471–476. doi:10.1097/00005768-200002000-00032
Subramanium, A., Honert, E. C., Cigoja, S., and Nigg, B. M. (2021). The effects of shoe upper construction on mechanical ankle joint work during lateral shuffle movements. J. Sports Sci. 39, 1791–1799. doi:10.1080/02640414.2021.1898174
Sun, X., Lam, W.-K., Zhang, X., Wang, J., and Fu, W. (2020). Systematic review of the role of footwear constructions in running biomechanics: implications for running-related injury and performance. J. Sports Sci. Med. 19, 20–37.
Tenforde, A., Hoenig, T., Saxena, A., and Hollander, K. (2023). Bone stress injuries in runners using carbon Fiber Plate footwear. Sports Med. 53, 1499–1505. doi:10.1007/s40279-023-01818-z
Warden, S. J., Davis, I. S., and Fredericson, M. (2014). Management and prevention of bone stress injuries in long-distance runners. J. Orthop. Sports Phys. Ther. 44, 749–765. doi:10.2519/jospt.2014.5334
Willson, J. D., Sharpee, R., Meardon, S. A., and Kernozek, T. W. (2014). Effects of step length on patellofemoral joint stress in female runners with and without patellofemoral pain. Clin. Biomech. Bristol Avon 29, 243–247. doi:10.1016/j.clinbiomech.2013.12.016
Willwacher, S., Kurz, M., Robbin, J., Thelen, M., Hamill, J., Kelly, L., et al. (2022). Running-related biomechanical risk factors for overuse injuries in distance runners: a systematic review considering injury specificity and the potentials for future research. Sports Med. 52, 1863–1877. doi:10.1007/s40279-022-01666-3
Worobets, J., Wannop, J. W., Tomaras, E., and Stefanyshyn, D. (2014). Softer and more resilient running shoe cushioning properties enhance running economy. Footwear Sci. 6, 147–153. doi:10.1080/19424280.2014.918184
Zhou, H., Chen, C., Xu, D., Ugbolue, U. C., Baker, J. S., and Gu, Y. (2021). Biomechanical characteristics between bionic shoes and normal shoes during the drop-landing phase: a pilot study. Int. J. Environ. Res. Public. Health 18, 3223. doi:10.3390/ijerph18063223
Keywords: lower limb biomechanics, carbon-fiber plate (CFP), running-induced fatigue, running performance, injury
Citation: Xu Y, Zhu C, Fang Y, Lu Z, Song Y, Hu C, Sun D and Gu Y (2025) The effects of different carbon-fiber plate shapes in shoes on lower limb biomechanics following running-induced fatigue. Front. Bioeng. Biotechnol. 13:1539976. doi: 10.3389/fbioe.2025.1539976
Received: 05 December 2024; Accepted: 24 January 2025;
Published: 11 February 2025.
Edited by:
Shuang Ren, Peking University Third Hospital, ChinaReviewed by:
Fan Yang, Li Ning Sports Science Research Center (LN-SSRC), ChinaCopyright © 2025 Xu, Zhu, Fang, Lu, Song, Hu, Sun and Gu. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Dong Sun, c3VuZG9uZ0BuYnUuZWR1LmNu; Yaodong Gu, Z3V5YW9kb25nQG5idS5lZHUuY24=
Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.
Research integrity at Frontiers
Learn more about the work of our research integrity team to safeguard the quality of each article we publish.