Erratum: Augmented transcutaneous stimulation using an injectable electrode: a computational study

  • Frontiers Media SA, Lausanne, Switzerland

An Erratum on
Augmented transcutaneous stimulation using an injectable electrode: a computational study

by Verma N, Graham RD, Mudge J, Trevathan JK, Franke M, Shoffstall AJ, Williams J, Dalrymple AN, Fisher LE, Weber DJ, Lempka SF and Ludwig KA (2021). Front. Bioeng. Biotechnol. 9:796042. doi: 10.3389/fbioe.2021.796042

Due to a production error, there was a mistake in the legend for Figure 7 as published. The caption for Figure 7C was written incorrectly as “(C) Box plot of activation thresholds of all on-target Aβ vagal fibers compared to all off-target Aβ cutanoues fibers responsible for paresthesia and off-target Aβ cutaneous fibers responsible for noxious sensations.”

The correct legend appears below.

“FIGURE 7 | (A) Full FEM model used in the biophysical study. The 1 kΩ resistor between the two collectors in the simplified transcutaneous coupling FEM model was replaced with the vagus nerve, Injectrode connections down to the vagus nerve, and Injectrode interfaces with the vagus nerve. This subfigure is reproduced from Figure 2C. (B) Box plot of all axons showing that the Injectrode system reduced the current required to activate Aβ vagal fibers by more than an order of magnitude compared to using only surface electrodes. This large difference was seen across TES patches of different sizes. (C) Box plot of activation thresholds of all on-target Aβ vagal fibers compared to all off-target Aβ cutanoues fibers responsible for paresthesia and off-target Aδ cutaneous fibers responsible for noxious sensations. (D) Investigating the effect of TES patch side length on cutaneous and vagus Aβ-fiber activation. Increasing the TES patch side length increasedmedian thresholds, and this effect was less pronounced in vagal Aβ fibers, improving the ratio of Aβ vagal activation to Aβ cutaneous activation. The Injectrode system achieved preferential on-target activation one to two orders of magnitude better than using surface stimulation electrodes alone.”

The publisher apologizes for this mistake.

Keywords: transcutaneous electrical nerve stimulation, neuromodulation, electrical stimulation (EStim), vagus nerve stimulation, electrode technology, selective stimulation of deep nerves, FEM, neuron simulation

Citation: Frontiers Production Office (2024) Erratum: Augmented transcutaneous stimulation using an injectable electrode: a computational study. Front. Bioeng. Biotechnol. 12:1431976. doi: 10.3389/fbioe.2024.1431976

Received: 13 May 2024; Accepted: 13 May 2024;
Published: 03 June 2024.

Approved by:

Frontiers Editorial Office, Frontiers Media SA, Switzerland

Copyright © 2024 Frontiers Production Office. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Frontiers Production Office, production.office@frontiersin.org

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.