The objectives of this study was to evaluate the effects of background color and restoration depth on color adjustment potential of a new single-shade resin composite versus multi-shade resin composites. Two multi-shade resin composites (Spectrum TPH3 and Clearfil AP-X) marked A2 shade and a new single-shade resin composite (Charisma Diamond One) were tested. Four base shades (A1, A2, A3, and A3.5) of the same resin composite (Filtek Z250) were selected as different background colors. Dual specimens with 1-, 2-, and 3-mm restoration depth and single specimens of all materials were fabricated. CIE color coordinates were measured using a spectrophotometer, then color differences (∆E00) and translucency parameter (TP00) were calculated using the CIEDE2000 formula. Independent observers performed visual scoring. CAP-I and CAP-V values were calculated according to ΔE00 and visual scoring. The results revealed that CAP-I and CAP-V were significantly affected by resin composite type, background color, and restoration depth. CAP-I and CAP-V decreased as restoration depth increased at the same background color for all materials. Charisma Diamond One had the highest CAP-I and CAP-V values at all background colors and restoration depths, with the highest TP00 value. These findings demonstrated that color adjustment potential was dependent on resin composite type, background color, and restoration depth, so shade selection is indispensable for multi-shade resin composites. Charisma Diamond One exhibited the highest color adjustment potential and the most pronounced color shifting, contributing to simplifying the process of shade selection and improving the efficiency of clinical work.
1 Introduction
Resin composites are now widely used as esthetic restorative materials in dentistry, which can perfectly achieve the restoration of tooth defect and the modification of tooth color and shape in a conservative and inexpensive way (Korkut and Türkmen, 2021; Da Rosa Rodolpho et al., 2022). Unlike indirect restorations made of ceramic materials whose color can be achieved by external staining at the later stage of treatment, the accurate shade selection is necessary for resin composite restorations before treatment, so as to select the materials closest to the color of the surrounding teeth for good esthetic effects (Ismail et al., 2020; Diamantopoulou et al., 2021; Vargas et al., 2023). The shade of resin composite selected based on a light-cured resin ball refers to placing a resin ball on the surface of tooth, comparing the color difference between the tooth and the resin ball after light-curing, and then removing it until a resin composite with the appropriate shade is determined by clinicians. Obviously, the shade selection of resin composite is complex and time-consuming (Browning et al., 2009; Tabatabaian et al., 2021).
In clinic, we can feel that the color differences between resin composites and surrounding tooth tissues are less perceived when viewed as a whole after finishing the restorations than when viewed separately before filling treatment (Tsubone et al., 2012; de Abreu et al., 2021). This phenomenon is called “chameleon effect” in dental parlance interpreted as color shifting which includes two major aspects: the blending effect (not measurable by any instrument, an optical illusion) and the effect of physical translucency (Paravina et al., 2008; Ismail and Paravina, 2022). More recently, color adjustment potential (CAP) is a term that describes and quantifies the interaction between the physical and perceptual components of color shifting, which can be assessed both instrumentally (CAP-I) and visually (CAP-V) (Trifkovic et al., 2018; Pereira Sanchez et al., 2019). Previous studies have shown that the CAP of resin composite is affected by many factors such as the type and shade of resin composite, background color, restoration depth, etc. (Tanaka et al., 2015; Akgül et al., 2022; El-Rashidy et al., 2022; Yamashita et al., 2023).
In order to minimize the shade selection, simplify the process of resin composite restoration, and reduce the chair-side time, single-shade resin composites were created and introduced, which have only a narrow range of colors but can match the colors of different teeth (de Abreu et al., 2021; Lucena et al., 2021; Altınışık and Özyurt, 2023). In other words, single-shade resin composites have enhanced CAP.
Recently, a newly developed single-shade resin composite (Charisma Diamond One, Kulzer, Hanau, Germany) has been introduced, which can supposedly match all Vita Classical shades according to the manufacturer’s information (Altınışık and Özyurt, 2023). However, no published third-party study has evaluated the CAP of the new single-shade resin composite compared with multi-shade resin composites to truly prove its superiority in color matching over conventional multi-shade resin composites.
Therefore, this study aimed to evaluate and compare the instrumental and visual color adjustment potential (CAP-I and CAP-V) of the newly developed single-shade resin composite compared with two clinically available multi-shade resin composites in relation to background color and restoration depth. The null hypotheses tested were: (1) there are no significant differences in color adjustment potential (CAP-I and CAP-V) among the resin composites evaluated, (2) background color or restoration depth would have no effect on the color adjustment potential (CAP-I and CAP-V).
2 Materials and methods
2.1 Specimen preparation
Two multi-shade resin composites marked A2 shade and a new single-shade resin composite were evaluated in this study. Four base shades (A1, A2, A3, and A3.5) of the same resin composite were selected to simulate different background colors. Details of these materials were listed in Table 1.
All specimens were made in custom-designed, Teflon molds (Figure 1). All specimens were filled in twice and each time filled the materials with a thickness of approximately 2 mm and then light-cured for 20 s using an LED light curing unit (Bluephase II; Ivoclar Vivadent, Schaan, Liechtenstein). The resin composite specimens were divided into four groups: three groups of dual specimens and one group of single specimens (Figure 2). The single specimens were disk-shaped (diameter = 10 mm, thickness = 4 mm) and fabricated for all materials included in this study (n = 9). The dual specimens consisted of an outer ring (diameter = 10 mm, thickness = 4 mm) made of base shades and an inner hole in the center (diameter = 6 mm) filled with each of the 3 tested materials after the cavities were treated with a transparent universal bonding agent (3 M-ESPE, St Paul, MN, United States) (n = 9). to According to the depth of the inner hole (corresponds to the thickness of the tested shade), dual specimens were divided into 3 groups including 1.0 mm-group, 2.0 mm-group, and 3.0 mm-group for each test material (Akgül et al., 2022; Yamashita et al., 2023).
FIGURE 1. Diagram for the fabrication of single and dual specimens. The heights of raised part in the hole of Teflon molds for dual specimens were 1.0 mm, 2.0 mm, and 3.0 mm respectively in different groups.
The same operator progressively polished all specimens on both sides using wet silicon carbide paper of increasing grit number (P600-, P800-, and P1200-grit) for 10 s each, at a speed of 150 rpm, with mild hand pressure in a table-top grinder-polisher (EcoMet 250; Buehler, Lake Bluff, IL, United States). All specimens were incubated at 37°C for 24 h to ensure complete polymerization.
2.2 Instrumental evaluation
A portable clinical spectroradiometer (Vita Easyshade V; VITA Zahnfabrik, Bad Sackingen, Germany) was used for the color measurements for all specimens against both black and white backgrounds. The probe (diameter = 5 mm) of spectroradiometer faced the center of the specimen during measurement. The spectrophotometer was calibrated in compliance with the manufacturer’s instructions before each measurement. L*, a*, and b* color coordinates based on the CIELAB system were recorded, where L* represents the lightness on a scale of 0 (black) to 100 (white), a* represents the hue and chroma on the red-green axis, and b* represents the hue and chroma on the yellow-blue axis.
Color coordinates measured were used for computation of color differences. The color difference (ΔE) was calculated using the CIEDE2000 color difference formula as follows (Perez Mdel et al., 2011):
In addition, translucency parameter (TP00) values were determined by calculating the color coordinates values between the readings over the black and white backgrounds according to the following CIEDE2000 color difference formula (Lucena et al., 2021):
2.3 Visual evaluation
Visual color evaluations were performed by three dentistry specialists with demonstrated superior color discrimination competency according to ISO/TR 28642:2016. Under D65 illumination and using a 0°/45° viewing geometry, the observers performed blind visual evaluations of all specimens placed on a neutral gray paper in a random order. Color differences were graded from 0 to 4 as follows: 0 = excellent match, 1 = very good match, 2 = not so good match (border zone mismatch), 3 = obvious mismatch, and 4 = huge (pronounced) mismatch.
2.4 Color adjustment potential (CAP) indices
The CAP indices included instrumental CAP (CAP-I) index and visual CAP (CAP-V) index (Figure 3).
FIGURE 3. The measurement areas of instrumental and visual evaluation; the calculation method of CAP-I and CAP-V.
CAP-I was calculated as follows: CAP-I = 1
CAP-V was calculated as follows: CAP-V = 1
2.5 Statistical analysis
Statistical analysis was performed with IBM SPSS Statistics for Mac (version 26; IBM Corp., Armonk, NY, United States). The data were presented as mean and standard deviation values. The result of the Shapiro–Wilk test showed that the data presented normal distribution (p > 0.05). A three-way analysis of variance (ANOVA) was used to analyze the effects of material type, background color, and restoration depth on ∆E00, CAP-I, and CAP-V values. The least significant difference (LSD) test and Dunnett’s T3 test were applied for multiple comparisons when significant variation was detected. The test standard was bilateral (α = 0.05 for all tests).
3 Results
Figure 4 showed representative single and dual specimens. In order to eliminate unwanted specular reflections on the surfaces of specimens caused by the flash, the photos were taken with a cross-polarization filter, which contributed to improving color selection and communication (Villavicencio-Espinoza et al., 2018; Sampaio et al., 2019; Jorquera et al., 2022).
The mean and standard deviation values of ∆E00 and visual scoring for the single specimens and the dual specimens with three restoration depths were respectively shown in Tables 2, 3. According to the results of multiple comparisons, ∆E00 values and visual scoring were both significantly affected by material type, background color, restoration depth, and specimen type (p < 0.001).
From the perspective of instrumental evaluation, for Charisma Diamond One, the ∆E00 values of all dual specimens were significantly lower than those of single specimens against the same background color. However, for Clearfil AP-X and Spectrum TPH3, the ∆E00 values of only a small portion of the dual specimens (mainly with 1-mm restoration depth) were significantly lower than those of the single specimens. But from the perspective of visual evaluation, the visual scorings of dual specimens were statistically significantly lower than or equal to those of single specimens at the same background color for all materials with different restoration depths. Nevertheless, for all materials, both ∆E00 values and visual scorings increased as restoration depth increased against the same background color.
In addition, at the same restoration depth, Clearfil AP-X showed the highest ∆E00 values and visual scorings against A1 base shade and the lowest mainly against A3/A3.5 base shade, Spectrum TPH3 showed the highest ∆E00 values and visual scorings against A3.5 base shade and the lowest mainly against A2 base shade, and Charisma Diamond One showed the highest ∆E00 values against A3.5 base shade and the lowest against A1 base shade.
According to the three-way ANOVA results, CAP-I and CAP-V values were both significantly affected by material type, background color, restoration depth, and their interactions (p < 0.001) (Table 4). Figure 5 presented the CAP-I and CAP-V values of three test materials with three restoration depths under four background colors. For all materials, both CAP-I and CAP-V decreased as restoration depth increased against the same background color. CAP-I values ranged from −0.45 to 0.79 and CAP-V values ranged from −0.02 to 0.77, both with the highest values consistently found for Charisma Diamond One among three test materials at the same background color and restoration depth (p < 0. 001).
FIGURE 5. The CAP-I and CAP-V values of three test materials with different restoration depths under four background colors.
Figure 6 showed the TP00 values of all test materials and base materials for the single specimens. Charisma Diamond One and Filtek Z250 (A1 shade) showed, respectively, the greatest and the lowest translucency values, with significant differences (p < 0.001). There was no statistically significant difference among the TP00 value of Spectrum TPH3, Filtek Z250 (A2 shade), and Filtek Z250 (As shade) (F = 0.396, p = 0.678), as well as between the TP00 value of Filtek Z250 (A1 shade) and Filtek Z250 (A3.5 shade) (F = 0.597, p = 0.560).
FIGURE 6. The TP00 values of all test materials and base materials for the single specimens. Different lowercase letters indicate the significant statistical difference (p < 0.05).
4 Discussion
The results of present study showed significant differences in both instrumental and visual color adjustment potential among all test resin composites at different background colors and restoration depths. Therefore, both experimental hypotheses were rejected.
The color adjustment potential can be evaluated instrumentally and visually. Color measurement instruments can describe the results in terms of color coordinates. Spectrophotometers have been proven to be useful and accurate instruments for measuring color in dentistry, which can improve the sensitivity and accuracy of measurement compared with visual evaluation (Karamouzos et al., 2007; Johnston, 2009). However, visual evaluation remains an important indicator for evaluating the color difference and color adjustment potential of resin composites (Chu et al., 2010), as it is the most commonly used method primary basis for clinicians and patients to determine the esthetic effect of resin composite restoration in clinic (de Abreu et al., 2021; Ruiz-López et al., 2022). Therefore, both instrumental and visual evaluation were used in present study to comprehensively compare the color adjustment potential of different resin composites. The CIELAB formula is frequently-used in the evaluation of color difference in dentistry. However, in order to achieve a better correlation between visual perception and instrumental evaluation, the recent color difference formula CIEDE2000 was developed and increasingly popular (Pecho et al., 2016; Günal-Abduljalil and Ulusoy, 2022).
The result from the present study was in accordance with previous investigations that the color difference of resin composite restoration depended on the material type and background color (Pereira Sanchez et al., 2019; de Abreu et al., 2021; Saegusa et al., 2021). Because the types and contents of base resins and fillers, as well as the size and shape of fillers, all have an impact on the color shifting ability of resin composites. Previous studies founded a positive correlation between the amount of Bis-GMA in the resin composite and its translucency because Bis-GMA has a higher translucency compared to UDMA and TEGDMA (Azzopardi et al., 2009; Miletic et al., 2017). And some studies also showed the color shifting ability of resin composites would improve with the increase in the filler contents (Altınışık and Özyurt, 2023). In addition, the size and shape of resin composite fillers determine the final surface properties of restorations, such as the size and shape of defects on the surfaces after polishing, resulting in the different wavelengths reflected from the surface and affecting the human perception of color (Sang et al., 2021; da Costa et al., 2021). Although the shade of all test resin composites (except Charisma Diamond One) was selected as A2 shade in this study, not all materials showed the lowest color difference under background of A2 shade. In this study, Spectrum TPH3 marked A2 shade matches the Filtek Z250 marked A2 shade best, with the lowest ∆E00 values and visual scoring among four background colors. However, Clearfil AP-X marked A2 shade matches the Filtek Z250 marked A3 or A3.5 shade best. Therefore, shade selection is indispensable in clinic when using multi-shade resin composites, especially when it comes to highly esthetic restorations (Ismail et al., 2020). The shade selection does not just determine the shade of the tooth needed treatment. More importantly, the shade of the resin composite selected based on the light-cured resin balls is necessary, because there are color differences between different resin composites marked the same shade.
CAP is a term representing color shifting referring to the interaction of dental materials with surrounding tissues, which determine the esthetic effect of resin composite (Ismail and Paravina, 2022). Equally, CAP was also depended on the material type and background color. The resin composite with positive CAP value means that it has less color differences when viewed together with surrounding after restoration than when viewed separately (Durand et al., 2021). Currently, there has been no uniform standard for the CAP value as a threshold of effective color shifting yet. Pereira et al. and Altınışık et al. thought that a CAP value of 0.20 (corresponding to a 20% reduction in the value of color difference in dual specimen compared with single specimen) was the threshold (Pereira Sanchez et al., 2019; Altınışık and Özyurt, 2023), while Durand et al. thought a CAP value of 0.50 was the threshold (Durand et al., 2021). However, there is no doubt that among all the materials tested, Charisma Diamond One exhibited the best and effective color shifting ability at all different background colors and restoration depths, with CAP-I or CAP-V values always greater than 0.20 and the vast majority greater than 0.5.
As expected, the color difference and CAP were significantly affected by restoration depth. The color difference (both ∆E00 value and visual scoring) increased as restoration depth increased against the same background color for all test materials, while CAP-I and CAP-V values decreased as restoration depth increased. This result indicated that the esthetic effect of resin material was declined as restoration depth increased, which highlighted the importance of layering technique in esthetic restoration of resin composite. The color construction of natural tooth is more complex than the experimental sample, so layering technique is necessary to simulate the optical properties of a natural tooth and minimize the color difference when it comes to resin composite restoration, especially for the anterior teeth with high esthetic requirements (Romero, 2015; Miotti et al., 2017; Ricci and Fahl, 2023).
Previous studies have reported that the CAP of resin composite increased in accordance with an increase in translucency (Paravina et al., 2006). Translucency is one of the primary factors in controlling esthetics and it can be evaluated by the translucency parameter (TP00) (Lucena et al., 2021). The higher the TP00 value is, the more light can be reflected from the background color into the composite restoration (Wang et al., 2013). This may explain the higher CAP-I and CAP-V values of Charisma Diamond One were recorded compared to other resin composites, with the highest TP00 value among all materials.
According to the manufacturer and literature, Charisma Diamond One utilizes “adaptive light matching” which determines the shade of the restoration by absorbing light waves reflected from the surrounding tooth shade. It contains urethane methacrylates, whose refractive index decreases as the size of side alkyl chain increases. Therefore, the translucency of Charisma Diamond One could increase after curing (Altınışık and Özyurt, 2023). On the other hand, due to the effect of the dark background in the oral cavity, the level of translucency that is incompatible with the surrounding structures can result in grayish restorations for the anterior teeth (Lucena et al., 2021). This also explains the higher ∆E00 value and visual scoring were recorded for Charisma Diamond One compared to other resin composites. One possible solution to this problem may be the “blocker”, which is used for the restoration of anterior teeth, so as to better combine the resin composite with the adjacent tooth structure (de Abreu et al., 2021).
Apart from the CAP, color difference is also an important indicator for evaluating the color shifting ability of resin composite. Some previous studies have proposed to adjust the acceptable threshold of color difference to ΔE00 ≤ 1.8 units (Paravina et al., 2015). According to this standard, only Spectrum TPH3 with 1- and 2-mm restoration depths under A2 background color and Charisma Diamond One with 1- and 2-mm restoration depths under A1 base shade displayed the acceptable color difference. However, ΔE00 value is affected by measuring instrument, illuminant condition, environment brightness, background color, and so on (Lagouvardos et al., 2009; Lee et al., 2010; Tabatabaian et al., 2021). The result of visual evaluation showed that most of the tested groups of the dual specimens were superior or equal to “border zone mismatch” (visual scoring ≤ 2). Combined with the result of visual evaluation, the acceptable threshold value of ΔE00 in this study should be higher than 1.8.
Based on the comprehensive results of this study, Charisma Diamond One had the best color shifting ability, for its better CAP at different background colors and restoration depths. Charisma Diamond One is likely to match different teeth colors, which contributes to simplifying the process of shade selection and improving the efficiency of clinical work. However, it may only be suitable for restoration of the posterior teeth. For the restoration of the anterior teeth with high esthetic requirements, its application may be limited by the fact that the color difference evaluated instrumentally or visually was not minimal all the time for it and it may result in grayish restorations.
The current study has several limitations. Only four background colors were evaluated and the specimen cannot completely simulate the color construction of a natural tooth. And the experimental conditions for color evaluation are different from clinical treatment. In addition, the color stability of resin composites can be significantly affected by the aging process in the oral environment such as changes in temperature and the absorption of colorants contained in foods and beverages, which affects the esthetic result and clinical longevity of resin composite restorations. The evaluation of these variables needs to be further studied in vivo and in vitro, which will provide more detailed information about the color properties of resin composites.
5 Conclusion
The color adjustment potential was significantly affected by resin composite type, background color, and restoration depth, regardless of instrumental or visual evaluation. Charisma Diamond One exhibited the most pronounced color shifting ability with the highest CAP-I and CAP-V values at all background colors and restoration depths, compared to other multi-shade resin composites. These findings demonstrated that shade selection is indispensable for multi-shade resin composites and Charisma Diamond One contributes to simplifying the process of shade selection and improving the efficiency of clinical work.
Data availability statement
The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author.
Author contributions
JZ: Conceptualization, Data curation, Formal Analysis, Investigation, Writing–original draft, Methodology. SC: Data curation, Investigation, Writing–original draft. AA: Investigation, Validation, Writing–original draft. YX: Visualization, Writing–original draft. CH: Conceptualization, Supervision, Writing–review and editing.
Funding
The author(s) declare financial support was received for the research, authorship, and/or publication of this article. This study was funded by the National Natural Science Foundation of China (grant number 82271010) and Horizontal Research Project of Wuhan University (grant number K23-1607-002).
Conflict of interest
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Publisher’s note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
References
Akgül, S., Gündoğdu, C., and Bala, O. (2022). Effects of storage time and restoration depth on instrumental color adjustment potential of universal resin composites. J. Oral Sci. 64, 49–52. doi:10.2334/josnusd.21-0290
Altınışık, H., and Özyurt, E. (2023). Instrumental and visual evaluation of the color adjustment potential of different single-shade resin composites to human teeth of various shades. Clin. Oral Investig. 27, 889–896. doi:10.1007/s00784-022-04737-x
Azzopardi, N., Moharamzadeh, K., Wood, D. J., Martin, N., and van Noort, R. (2009). Effect of resin matrix composition on the translucency of experimental dental composite resins. Dent. Mater 25, 1564–1568. doi:10.1016/j.dental.2009.07.011
Browning, W. D., Contreras-Bulnes, R., Brackett, M. G., and Brackett, W. W. (2009). Color differences: polymerized composite and corresponding Vitapan Classical shade tab. J. Dent. 37 (Suppl. 1), e34–e39. doi:10.1016/j.jdent.2009.05.008
Chu, S. J., Trushkowsky, R. D., and Paravina, R. D. (2010). Dental color matching instruments and systems. Review of clinical and research aspects. J. Dent. 38 (Suppl. 2), e2–e16. doi:10.1016/j.jdent.2010.07.001
da Costa, J. B., Ferracane, J. L., Amaya-Pajares, S., and Pfefferkorn, F. (2021). Visually acceptable gloss threshold for resin composite and polishing systems. J. Am. Dent. Assoc. 152, 385–392. doi:10.1016/j.adaj.2020.09.027
Da Rosa Rodolpho, P. A., Rodolfo, B., Collares, K., Correa, M. B., Demarco, F. F., Opdam, N. J. M., et al. (2022). Clinical performance of posterior resin composite restorations after up to 33 years. Dent. Mater 38, 680–688. doi:10.1016/j.dental.2022.02.009
de Abreu, J. L. B., Sampaio, C. S., Benalcázar Jalkh, E. B., and Hirata, R. (2021). Analysis of the color matching of universal resin composites in anterior restorations. J. Esthet. Restor. Dent. 33, 269–276. doi:10.1111/jerd.12659
Diamantopoulou, S., Kakaboura, A., Margaritis, V., and Papazoglou, E. (2021). Color comparison of three layered resin composite systems with three shade guides. J. Esthet. Restor. Dent. 33, 323–340. doi:10.1111/jerd.12610
Durand, L. B., Ruiz-López, J., Perez, B. G., Ionescu, A. M., Carrillo-Pérez, F., Ghinea, R., et al. (2021). Color, lightness, chroma, hue, and translucency adjustment potential of resin composites using CIEDE2000 color difference formula. J. Esthet. Restor. Dent. 33, 836–843. doi:10.1111/jerd.12689
El-Rashidy, A. A., Abdelraouf, R. M., and Habib, N. A. (2022). Effect of two artificial aging protocols on color and gloss of single-shade versus multi-shade resin composites. BMC Oral Health 22, 321. doi:10.1186/s12903-022-02351-7
Günal-Abduljalil, B., and Ulusoy, M. M. (2022). The effect of resin cement shade and restorative material type and thickness on the final color of resin-matrix ceramics. J. Prosthodont Res. 66, 75–82. doi:10.2186/jpr.JPR_D_20_00138
Ismail, E. H., Dawson, D. V., and Maia, R. R. (2020). A novel sample design for determining color compatibility between layered resin composite and vita shade guides. J. Esthet. Restor. Dent. 32, 34–42. doi:10.1111/jerd.12530
Ismail, E. H., and Paravina, R. D. (2022). Color adjustment potential of resin composites: optical illusion or physical reality, a comprehensive overview. J. Esthet. Restor. Dent. 34, 42–54. doi:10.1111/jerd.12843
Johnston, W. M. (2009). Color measurement in dentistry. J. Dent. 37 (Suppl. 1), e2–e6. doi:10.1016/j.jdent.2009.03.011
Jorquera, G. J., Atria, P. J., Galán, M., Feureisen, J., Imbarak, M., Kernitsky, J., et al. (2022). A comparison of ceramic crown color difference between different shade selection methods: visual, digital camera, and smartphone. J. Prosthet. Dent. 128, 784–792. doi:10.1016/j.prosdent.2020.07.029
Karamouzos, A., Papadopoulos, M. A., Kolokithas, G., and Athanasiou, A. E. (2007). Precision of in vivo spectrophotometric colour evaluation of natural teeth. J. Oral Rehabil. 34, 613–621. doi:10.1111/j.1365-2842.2007.01744.x
Korkut, B., and Türkmen, C. (2021). Longevity of direct diastema closure and recontouring restorations with resin composites in maxillary anterior teeth: a 4-year clinical evaluation. J. Esthet. Restor. Dent. 33, 590–604. doi:10.1111/jerd.12697
Lagouvardos, P. E., Fougia, A. G., Diamantopoulou, S. A., and Polyzois, G. L. (2009). Repeatability and interdevice reliability of two portable color selection devices in matching and measuring tooth color. J. Prosthet. Dent. 101, 40–45. doi:10.1016/s0022-3913(08)60289-9
Lee, Y. K., Yu, B., Lee, S. H., Cho, M. S., Lee, C. Y., and Lim, H. N. (2010). Variation in instrument-based color coordinates of esthetic restorative materials by measurement method-A review. Dent. Mater 26, 1098–1105. doi:10.1016/j.dental.2010.07.010
Lucena, C., Ruiz-López, J., Pulgar, R., Della Bona, A., and Pérez, M. M. (2021). Optical behavior of one-shaded resin-based composites. Dent. Mater 37, 840–848. doi:10.1016/j.dental.2021.02.011
Miletic, V., Jakovljevic, N., Manojlovic, D., Marjanovic, J., Rosic, A. A., and Dramićanin, M. D. (2017). Refractive indices of unfilled resin mixtures and cured composites related to color and translucency of conventional and low-shrinkage composites. J. Biomed. Mater Res. B Appl. Biomater. 105, 7–13. doi:10.1002/jbm.b.33523
Miotti, L. L., Santos, I. S., Nicoloso, G. F., Pozzobon, R. T., Susin, A. H., and Durand, L. B. (2017). The use of resin composite layering technique to mask discolored background: a CIELAB/ciede2000 analysis. Oper. Dent. 42, 165–174. doi:10.2341/15-368-l
Paravina, R. D., Ghinea, R., Herrera, L. J., Bona, A. D., Igiel, C., Linninger, M., et al. (2015). Color difference thresholds in dentistry. J. Esthet. Restor. Dent. 27 (Suppl. 1), S1–S9. doi:10.1111/jerd.12149
Paravina, R. D., Westland, S., Imai, F. H., Kimura, M., and Powers, J. M. (2006). Evaluation of blending effect of composites related to restoration size. Dent. Mater 22, 299–307. doi:10.1016/j.dental.2005.04.022
Paravina, R. D., Westland, S., Johnston, W. M., and Powers, J. M. (2008). Color adjustment potential of resin composites. J. Dent. Res. 87, 499–503. doi:10.1177/154405910808700515
Pecho, O. E., Ghinea, R., Alessandretti, R., Pérez, M. M., and Della Bona, A. (2016). Visual and instrumental shade matching using CIELAB and CIEDE2000 color difference formulas. Dent. Mater 32, 82–92. doi:10.1016/j.dental.2015.10.015
Pereira Sanchez, N., Powers, J. M., and Paravina, R. D. (2019). Instrumental and visual evaluation of the color adjustment potential of resin composites. J. Esthet. Restor. Dent. 31, 465–470. doi:10.1111/jerd.12488
Perez Mdel, M., Ghinea, R., Herrera, L. J., Ionescu, A. M., Pomares, H., Pulgar, R., et al. (2011). Dental ceramics: a CIEDE2000 acceptability thresholds for lightness, chroma and hue differences. J. Dent. 39 (Suppl. 3), e37–e44. doi:10.1016/j.jdent.2011.09.007
Ricci, W. A., and Fahl, N. (2023). Nature-mimicking layering with composite resins through a bio-inspired analysis: 25 years of the polychromatic technique. J. Esthet. Restor. Dent. 35, 7–18. doi:10.1111/jerd.13021
Romero, M. F. (2015). Esthetic anterior composite resin restorations using a single shade: step-by-step technique. J. Prosthet. Dent. 114, 9–12. doi:10.1016/j.prosdent.2015.02.013
Ruiz-López, J., Perez, M. M., Lucena, C., Pulgar, R., López-Toruño, A., Tejada-Casado, M., et al. (2022). Visual and instrumental coverage error of two dental shade guides: an in vivo study. Clin. Oral Investig. 26, 5961–5968. doi:10.1007/s00784-022-04556-0
Saegusa, M., Kurokawa, H., Takahashi, N., Takamizawa, T., Ishii, R., Shiratsuchi, K., et al. (2021). Evaluation of color-matching ability of a structural colored resin composite. Oper. Dent. 46, 306–315. doi:10.2341/20-002-l
Sampaio, C. S., Atria, P. J., Hirata, R., and Jorquera, G. (2019). Variability of color matching with different digital photography techniques and a gray reference card. J. Prosthet. Dent. 121, 333–339. doi:10.1016/j.prosdent.2018.03.009
Sang, E. J., Song, J. S., Chung, S. H., Jin, B. H., and Hyun, H. K. (2021). Influence of a new polishing system on changes in gloss and surface roughness of resin composites after polishing and brushing. Dent. Mater J. 40, 727–735. doi:10.4012/dmj.2020-207
Tabatabaian, F., Beyabanaki, E., Alirezaei, P., and Epakchi, S. (2021). Visual and digital tooth shade selection methods, related effective factors and conditions, and their accuracy and precision: a literature review. J. Esthet. Restor. Dent. 33, 1084–1104. doi:10.1111/jerd.12816
Tanaka, A., Nakajima, M., Seki, N., Foxton, R. M., and Tagami, J. (2015). The effect of tooth age on colour adjustment potential of resin composite restorations. J. Dent. 43, 253–260. doi:10.1016/j.jdent.2014.09.007
Trifkovic, B., Powers, J. M., and Paravina, R. D. (2018). Color adjustment potential of resin composites. Clin. Oral Investig. 22, 1601–1607. doi:10.1007/s00784-017-2260-6
Tsubone, M., Nakajima, M., Hosaka, K., Foxton, R. M., and Tagami, J. (2012). Color shifting at the border of resin composite restorations in human tooth cavity. Dent. Mater 28, 811–817. doi:10.1016/j.dental.2012.04.032
Vargas, M., Saisho, H., Maharishi, A., and Margeas, R. (2023). A practical, predictable, and reliable method to select shades for direct resin composite restorations. J. Esthet. Restor. Dent. 35, 19–25. doi:10.1111/jerd.13019
Villavicencio-Espinoza, C. A., Narimatsu, M. H., and Furuse, A. Y. (2018). Using cross-polarized photography as a guide for selecting resin composite shade. Oper. Dent. 43, 113–120. doi:10.2341/16-227-t
Wang, F., Takahashi, H., and Iwasaki, N. (2013). Translucency of dental ceramics with different thicknesses. J. Prosthet. Dent. 110, 14–20. doi:10.1016/s0022-3913(13)60333-9
Keywords: color adjustment potential, resin composites, color shifting, single shade, CIEDE2000
Citation: Zhu J, Chen S, Anniwaer A, Xu Y and Huang C (2023) Effects of background color and restoration depth on color adjustment potential of a new single-shade resin composite versus multi-shade resin composites. Front. Bioeng. Biotechnol. 11:1328673. doi: 10.3389/fbioe.2023.1328673
Received: 27 October 2023; Accepted: 24 November 2023;
Published: 07 December 2023.
Edited by:
Wenjie Zhang, Shanghai Jiao Tong University, ChinaReviewed by:
Xiaodong Wang, Sun Yat-sen University, ChinaYang Zhen, Peking University Hospital of Stomatology, China
Copyright © 2023 Zhu, Chen, Anniwaer, Xu and Huang. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Cui Huang, aHVhbmdjdWlAd2h1LmVkdS5jbg==