Skip to main content

ORIGINAL RESEARCH article

Front. Physiol., 13 August 2020
Sec. Cardiac Electrophysiology
This article is part of the Research Topic Risk Factors of Noninvasive Cardiac Electrophysiology View all 21 articles

Body Surface Mapping of Ventricular Repolarization Heterogeneity: An Ex-vivo Multiparameter Study

  • 1Institute of Electrophysiology and Heart Modeling (IHU Liryc), Foundation Bordeaux University, Pessac-Bordeaux, France
  • 2University of Bordeaux, CRCTB, Bordeaux, France
  • 3INSERM, CRCTB, U1045, Bordeaux, France
  • 4Department of Data Science and Knowledge Engineering, Maastricht University, Maastricht, Netherlands
  • 5Department of Cardiology, Cardiovascular Research Institute Maastricht, Maastricht University Medical Center, Maastricht, Netherlands
  • 6Bordeaux University Hospital (CHU), Electrophysiology and Ablation Unit, Pessac, France

Background: Increased heterogeneity of ventricular repolarization is associated with life-threatening arrhythmia and sudden cardiac death (SCD). T-wave analysis through body surface potential mapping (BSPM) is a promising tool for risk stratification, but the clinical effectiveness of current electrocardiographic indices is still unclear, with limited experimental validation. This study aims to investigate performance of non-invasive state-of-the-art and novel T-wave markers for repolarization dispersion in an ex vivo model.

Methods: Langendorff-perfused pig hearts (N = 7) were suspended in a human-shaped 256-electrode torso tank. Tank potentials were recorded during sinus rhythm before and after introducing repolarization inhomogeneities through local perfusion with dofetilide and/or pinacidil. Drug-induced repolarization gradients were investigated from BSPMs at different experiment phases. Dispersion of electrical recovery was quantified by duration parameters, i.e., the time interval between the peak and the offset of T-wave (TPEAK-TEND) and QT interval, and variability over time and electrodes was also assessed. The degree of T-wave symmetry to the peak was quantified by the ratio between the terminal and initial portions of T-wave area (Asy). Morphological variability between left and right BSPM electrodes was measured by dynamic time warping (DTW). Finally, T-wave organization was assessed by the complexity of repolarization index (CR), i.e., the amount of energy non-preserved by the dominant eigenvector computed by principal component analysis (PCA), and the error between each multilead T-wave and its 3D PCA approximation (NMSE). Body surface indices were compared with global measures of epicardial dispersion of repolarization, and with local gradients between adjacent ventricular sites.

Results: After drug intervention, both regional and global repolarization heterogeneity were significantly enhanced. On the body surface, TPEAK-TEND was significantly prolonged and less stable in time in all experiments, while QT interval showed higher variability across the interventions in terms of duration and spatial dispersion. The rising slope of the repolarization profile was steeper, and T-waves were more asymmetric than at baseline. Interventricular shape dissimilarity was enhanced by repolarization gradients according to DTW. Organized T-wave patterns were associated with abnormal repolarization, and they were properly described by the first principal components.

Conclusion: Repolarization heterogeneity significantly affects T-wave properties, and can be non-invasively captured by BSPM-based metrics.

Introduction

Abnormal heterogeneity of ventricular repolarization predisposes to the development of life−threatening ventricular arrhythmias and it is associated with increased mortality in the general population (Antzelevitch, 2007; Prenner et al., 2016).

Global ventricular repolarization dispersion is mainly determined by the heterogeneity of action potential durations (APDs) between different myocardial regions, which can be apical-basal (from apex to base of ventricles), transmural (from endocardium to epicardium) and/or interventricular (left vs. right ventricle), and thus affects T-wave properties from surface electrocardiogram (ECG) (Merri et al., 1989; Vinzio Maggio et al., 2012). Classically, global dispersion of repolarization has been defined as the difference between longest and shortest repolarization time (RT) within a set of measurements at multiple sites without regard to their location (Burton and Cobbe, 2001). On the other hand, regional dispersion of repolarization strongly affects T-wave profile as well, therefore measures of local inhomogeneity have also been introduced to take into account spatial distribution of RTs and their variations across adjacent tissue sites. Patients with long QT syndrome display regions with steep repolarization dispersion caused by localized prolongation of APD and genotype-specific alterations in T- wave morphology (Vijayakumar et al., 2014). In Brugada syndrome, sharp local gradients of repolarization and slow conduction areas can both contribute to increased susceptibility to sustained reentrant excitation and are accompanied by T-wave inversion on the body surface (Zhang et al., 2015).

Both abnormal global and local dispersion of repolarization significantly affect T-wave characteristics. Nevertheless, it is still unclear if T-wave properties are more influenced by one of these two conditions, or if both equally contribute to the electrocardiographic alterations of ventricular recovery. Accordingly, the performance of state-of-the-art ECG markers of T-wave has been questioned in clinics, due to their inability to identify vulnerable substrates and reliably distinguish between healthy and diseased subjects (Malik et al., 2000; Van Huysduynen et al., 2005; Smetana et al., 2011; Marill et al., 2018). Since each ECG electrode summarizes the integrated electrical activity over the entire heart, spatial properties of the cardiac generator are lost, and it was shown that features derived from such a low number of electrodes are unlikely to reflect regional changes in myocardial repolarization (Burnes et al., 2001).

To compensate this intrinsic limitation of ECG, high-density body surface mapping (BSPM) has emerged as a promising tool for the diagnosis of T-wave alterations and risk stratification for sudden cardiac death (SCD) (Taccardi et al., 2007; Korhonen et al., 2009). Several studies have confirmed the ability of this technique to capture non-dipolarities of cardiac electrical activity, and on top of that ECG imaging could localize sites of abnormal recovery (Peeters et al., 1998; Burnes et al., 2001; Vijayakumar et al., 2014; Zhang et al., 2015).

Despite these advances, it is still unclear how regional and global repolarization disparities reflect on body surface, and to which extent they can be inferred from BSPMs, as pre-clinical validation is limited and different invasive metrics are used for validation (Fuller et al., 2000; Burnes et al., 2001).

Our study takes a step further from this background and aims to assess the ability of several state-of-the-art and novel BSPM metrics to describe abnormal dispersion of repolarization in an ex vivo torso tank model, for which information about actual heterogeneity of repolarization at the heart level is available, and can be used for validation of body-surface indices.

Materials and Methods

Experimental Setup and Database

The experimental protocol was approved by Directive 2010/63/EU of the European Parliament on the protection of animals used for scientific purposes and the local ethical committee. Hearts were excised from pigs (N = 7, 30–40 kg) and perfused in Langendorff setup as previously reported (Bear et al., 2019a, c). The left anterior descending (LAD) artery was cannulated on a separate perfusion. A 108-electrode sock was attached to the free wall epicardial surfaces of the ventricles. After instrumentation, the heart was suspended in a human-shaped 256-electrode torso tank filled with a Tyrode’s solution. In 3 hearts, pinacidil (Pin) was injected in increasing concentrations (full dose: 30 μM) into the LAD to locally shorten APD and induce gradients in repolarization with other myocardial regions (Pin Group). In the other 4 hearts, Pin administration with comparable doses was preceded by progressive perfusion of non-LAD coronaries with dofetilide (Dof, full dose: 250 nM) to further enhance regional repolarization heterogeneities (early repolarization in the Pin-area, late in the Dof-area). This second set was referred to as Dof & Pin Group. Only experiments presenting all mentioned phases were assigned to one of these categories, therefore other phases which were not common to all experiments (e.g., drug washout) were not included into our analysis. When more recordings were available at baseline, the first recording was included into our analysis. During drug perfusion, the last recording was generally preferred, in order to have enough time for the drug to make effect.

Signal Preprocessing and Fiducial Point Detection

BSPMs and sock electrograms (EGMs) were simultaneously recorded (BioSemi, Netherlands) at a sampling rate of 2048 Hz during sinus rhythm before and after each drug intervention over Nb = 10 beats.

At each beat i, i = 1,…,Nb, T-waves from all electrodes were arranged as a L×N matrix Y(i) = [y(1)…y(N)] ∈ ℜL×N, with L=256 equal to the number of tank electrodes, and N to the number of time samples. Since electrodes presenting signals with too high levels of noise and/or low voltage on visual inspection have not been included into our analysis, in some cases we may have L < 256. A representative single-lead beat with its characteristic deflections from an experiment from Dof & Pin Group is shown at each drug state in Figure 1.

FIGURE 1
www.frontiersin.org

Figure 1. A representative single-lead QRST sequence from a tank potential recorded from an experiment from Dof & Pin Group before (Baseline, blue trace) and after induction of repolarization gradients through injection of dofetilide (Dof, green trace) and simultaneous perfusion with dofetilide and pinacidil (Dof + Pin, red trace).

High frequency noise was removed from BSPMs by a low-pass least-squares linear-phase finite impulse response (FIR) filter with cutoff frequency at 40 Hz. Power line interference was suppressed by a discrete Fourier transform-based notch filter. Prior to morphology analysis in section 2.3.3 and 2.3.4, a third-order Savitzky-Golay FIR filter with 50 ms frame length was applied to remove residual noise interferences and further smoothen T-wave profile.

R-wave peak time occurrences were identified from tank potentials as signal local maxima above a preset threshold equal to the half of the signal maximum amplitude value, and at a minimum time distance of 330 ms, using the MATLAB function findpeaks. QRS complex onset and offset were detected using a modified version of the algorithm proposed in Nygårds and Sörnmo (1983). Briefly, the envelope of the input signal was computed as the modulus of its Hilbert transform and denoted xenv. In the 60 ms interval preceding each heartbeat, potential candidate QRS onset values QRS~ON were identified as the local maxima above a fixed threshold equal to 0.2 ×max(xenv), with max(xenv) standing for the maximum value of the numerical gradient of xev. In this time frame, we computed the curvature of function xenv as: Cenv=xenv1+xenv23, with xenv equal to the gradient of xenv. Doing so, the exact time location of each QRS onset QRSON could be finally determined as that of Cenv local maximum in the 100 ms interval before the earliest QRS~ON.

An improved version of Woody’s method for time delay estimation was applied to each BSPM electrode to detect the offset of T-wave (TOFF) (Cabasson and Meste, 2008). This method introduces an iterative maximum likelihood estimator to analyze variable latency signal. According to this approach, at each instant t a generic signal xi(t) can be modeled as:

x i ( t ) = s ( t - d i ) + e i ( t ) ,

with s(tdi) defined as the unknown reference wave delayed by di and ei(t) as observation’s white Gaussian noise, for i = 1,…,Nb. For our application, a fixed-length search window has been used for all electrodes to detect the end of T-wave at each heartbeat, with duration set between 200 and 300 ms depending on signal characteristics. As demonstrated by Cabasson and Meste (2008), each T-wave can be detected under an iterative scheme which determines the time lags d^i,i=1,,Nb as those maximizing the correlation with a template waveform:

d ^ i = arg m a x d [ t i N b k > i N b x k ( t + d k ) x i ( t + d i ) ]

Under the constraint that idi=0, and with the template wave equal to the mean of all delayed waves xk(t + dk) except for the one currently examined. The delays d^i are finally used to determine the final location of T-wave end TOFF after each R-wave. The algorithm was applied to each electrode separately, but with a fixed search frame.

T-wave peak (TPEAK) was detected from each lead as the time instant of the local maximum (minimum) of T-wave with positive (negative) polarity in the time interval starting 100 ms after the R-wave occurrence and ending at TEND. The onset of T-wave (TON) was finally identified at 0.3×TFRAME samples after R-wave peak time instant, with TFRAME equal to the median duration of the R-peak-T-wave offset interval over all leads. The time location of T-wave fiducial points was corrected if possible, otherwise BSPM electrodes associated with misdetections due to flat repolarization were discarded from our analysis.

Standard and Novel Electrocardiographic Features of Myocardial Repolarization

In this section, we introduce several descriptors of T-wave and we evaluate their ability to non-invasively capture abnormal gradients in repolarization. We investigate to which extent the heterogeneity observed at the level of the tissue can be quantified on body surface, as abnormal dispersion of repolarization is known to strongly affect T-wave characteristics, in terms of: (a) duration; (b) variability duration; (c) shape; (d) spatial complexity, although the mechanistic link is not always clear and findings from previous studies are sometimes in mutual contradiction (Priori et al., 1997; Antzelevitch, 2001; Porthan et al., 2013). Accordingly, moving from previous research we define some markers of duration, morphology and spatial content of T-wave. Since in previous works most of these indices have been merely assessed from one or more beats in single-lead or 12-lead ECGs, we investigated whether equivalent BSPM-derived metrics could provide equally or more detailed information on repolarization abnormalities in our torso-tank model. A brief definition of each BSPM- and EGM-based indices is presented in Table 1.

TABLE 1
www.frontiersin.org

Table 1. Summary of all EGM- and BSPM-derived metrics of ventricular repolarization investigated in this study.

Duration (TPEAK-TEND, QTC)

Time domain descriptors of ventricular electrical recovery were computed from surface potentials at each experimental stage. At each beat and from each electrode, we measured the duration of the time interval between the peak TPEAK and the end of T-wave TOFF, which has been regarded as an index of transmural dispersion of repolarization (Yan and Antzelevitch, 1998; Antzelevitch et al., 1999). For our analysis, the median value of the duration of this interval over all heartbeats was computed from each electrode and denoted TPEAK-TEND.

We also investigated the role of QT interval as a marker for impaired electrical recovery, as its abnormal prolongation is known to be proarrhythmic (Straus et al., 2006). Accordingly, at each beat i and in each electrode ℓ the duration QTℓ,i of the interval between the beginning of the QRS complex QON and the T-wave offset TOFF was measured and corrected for heart rate using Bazett’s formula QTC,i = QTℓ,i/(RRm)0.5, with RRm equal to the mean RR interval. The median of corrected QT values over all beats was computed from each tank electrode (QTC) and used for subsequent analysis.

Duration Variability [SD(TPEAK-TEND), QTD]

The variability of cardiac repolarization was also determined in terms of temporal or beat-to-beat variability. Accordingly, we assessed temporal inhomogeneity of TPEAK-TEND duration by computing the standard deviation of the peak-to-end T-wave interval durations across heartbeats from each BSPM electrode and denoted SD(TPEAK-TEND), as it is known to be increased in subjects at higher risk for SCD (Piccirillo et al., 2013).

Finally, QTc interval dispersion (QTD) was also calculated as the difference between maximum and minimum QT over BSPM electrodes, being a routine measure of spatial heterogeneity of repolarization in clinics (Baumert et al., 2016).

Shape (Asy, dLV/RV)

As in Di Bernardo and Murray (2000) and Sheridan et al. (2010), in each electrode ℓ = 1,…,L and at each heartbeat beat i, i = 1,…,Nb, we computed an index of symmetry of T-wave as the ratio between the area of the terminal portion of the repolarization (corresponding with the TPEAK-TEND interval) and that between the onset and the peak of T-wave (i.e., the TON-TPEAK interval):

A s y , i = T P E A K T E N D y , i ( t ) d t T O N T P E A K y , i ( t ) d t

According to these works, more symmetrical T-waves were associated with increased repolarization heterogeneity, with index values closer to unity. Indeed, normal T waves should have a gradual upstroke with a slightly steeper descending limb, and abnormal dispersion of repolarization seems to alter relative contribution of these two portions. In our study, T-waves were mean-centered and normalized between 0 and 1. Integrals were discretized through the trapezoidal rule. The median of the asymmetry index over all beats was determined from each BSPM electrode and taken as a marker of repolarization dispersion (Asy).

T-wave morphology aberrations have been linked to abnormal heterogeneity of ventricular repolarization and increased arrhythmia vulnerability. Right-to-left ventricle dispersion is an important factor contributing to heterogeneous repolarization both in physiological (Hlaing et al., 2005) and pathological conditions (Fish et al., 2004), and it can affect T wave profile (Srinivasan et al., 2019). Dynamic time warping (DTW) has been previously proposed to describe T-wave beat-to-beat morphological changes, assess temporal variability of ventricular recovery from 12-lead ECG and predict SCD risk in chronic heart failure patients (Ramirez et al., 2017). Accordingly, moving from this theory we investigated whether drug-induced repolarization gradients may contribute to interventricular dispersion and be assessed by T-wave shape analysis. Specifically, we split BSPM electrodes into a set of LLV electrodes associated with the left ventricle (LV; from the left side of the heart) and one consisting of LRV electrodes for the right ventricle (RV; from the right side of the heart), and we applied DTW to measure the degree of similarity between waveforms from pairs of tank potentials, each associated with a different ventricle. Algorithm details are reported elsewhere (Müller, 2007). Briefly, this approach aims to find the match between two temporal sequences along an optimal alignment path by minimizing a cost function. In our study we choose the Euclidean distance as a similarity metric. A median T-wave signal was computed over all beats from each electrode and given as input to the algorithm after mean-centering and signal normalization by L2-norm. The cumulative distance dLV/RV minimizing the warping path between the examined pair of signals was used as a T-wave parameter, with higher values of the index denoting higher dissimilarity between the waveforms and increased heterogeneity of the ventricular recovery.

Complexity (CR, NMSE)

Due to its ability to capture inhomogeneities and variability of repolarization, principal component analysis (PCA) has been suggested as a tool to measure the spatial organization of T-wave (Priori et al., 1997; Malik et al., 2000; Zabel and Malik, 2001), under the hypothesis that cardiac activity can be approximated to a 3D electric dipole (Holt et al., 1969), and that components outside the T-wave loops would reflect pathological inhomogeneities and represent an arrhythmic substrate (Okin et al., 2002; Porthan et al., 2013). Accordingly, in line with this research, we assessed body surface electrical organization as follows. At each heartbeat i,i = 1,…,Nb, a multi-electrode T-wave matrix Y(i),i = 1,…,Nb was segmented between TON and the median value of TEND over all leads. T-wave matrix was then factorized by singular value decomposition Y(i) = VT, with U and V representing the right and left singular vectors, respectively, and Σ being a diagonal matrix containing the singular values σ, ℓ = 1,…,L. As in Priori et al. (1997), we measured the relative contribution of the dominant eigenvector over total signal variation by computing the complexity of repolarization (CR) as:

C R = = 2 L σ 2 = 1 L σ 2 100

Lower CR values were assumed to describe less complex T-wave patterns and homogeneous repolarization, as one major spatial component (eigenvector) should be able to accurately describe such an organized process. Conversely, spatial repolarization heterogeneities were expected to require a higher number of components for accurate PCA reconstruction, thus yielding higher CR.

Additionally, we used PCA to explore the temporal variability of T-wave spatial components over higher-order spaces. Specifically, after normalization between 0 and 1 and mean-centering, at each beat, i = 1,…,Nb PCA was applied to Y(i) to compute a 3D subspace M(i) onto which every subsequent T-waveY(j),ji, was projected. The normalized mean square error (NMSE) between the input potentials Y(j) and their low-rank PCA approximation was then computed as:

N M S E ( j ) = ( I - M ( i ) M ( i ) # ) Y ( j ) Y ( j ) 100

For j = 1,…,Nb, ji, with M(i)# = [M(i)TM(i)]−1M(i)T being the pseudo-inverse of M(i) (Bonizzi et al., 2010; Meo et al., 2013). At each beat, the average NMSE over all tank electrodes was finally considered as a descriptor of T-wave repolarization, assuming that higher reconstruction error would render a higher degree of spatiotemporal dispersion of repolarization.

Validation of Body Surface Signal Processing Algorithms

To confirm whether changes in BSPM parameters across each experiment truly reflected alterations in repolarization characteristics, at each experimental step every non-invasive index was averaged over all electrodes and/or heartbeats, and their time evolution across the experiment was compared with that of several invasive epicardial markers of repolarization dispersion.

To verify the ability of BSPM-derived features to assess global dispersion of repolarization, at each heartbeat we computed the absolute difference RTGGLOBAL between the spatial average of RTs over sock electrodes from differently perfused epicardial regions, i.e., between mean RT from electrodes in the Pin-area and those in non-perfused sites for Pin Group, and between mean RT from electrodes in the Pin-area and those in the Dof-area for Dof & Pin Group.

Additionally, at each beat we also measured the absolute difference between mean RTs from sock electrodes in contact with LV and those attached to RV (RTG(LV/RV)GLOBAL).

We also investigated whether body surface analysis could identify regional repolarization gradients at a smaller scale. Accordingly, for validation at each beat we quantified the local spatial RT gradient RTGLOCAL, i.e., the temporal average of the maximum differences between RTs from two adjacent EGM sites, divided by their Euclidean distance (Vijayakumar et al., 2014). The higher its value, the steeper the local repolarization gradients between neighboring sites. Specifically, for experiments from Pin Group, each invasive and non-invasive parameter was assessed: (1) at the beginning of the experiment, in the absence of drug-induced repolarization gradients (“Baseline”); (2) during LAD coronary perfusion with half concentration of pinacidil (15 μM, “1/2 Pin”); (3) during perfusion of the same site will full concentration of pinacidil (30 μM, “1/1 Pin”). Similarly, we computed all parameters for Dof & Pin Group at three experimental phases as well: (1) “Baseline”; (2) during injection of dofetilide (250 nM) in extra-LAD areas (“Dof”); (3) during injection of pinacidil (between 15 and 30 μM) in the LAD coronary (“Dof + Pin”). While in the Pin Group it has been possible to inject the total drug dose during all interventions, in two hearts (#3 and #4) from the Dof & Pin Group the experiments could not be completed due to some technical problems with LAD cannulation, thus only half dose of pinacidil could be used. Nevertheless, a clear effect of the drug on these additional hearts was observed despite the use of a lower pinacidil concentration, with visible and interpretable impact on repolarization properties, thus all the signal recordings could be eventually used and analyzed. To better understand the ability of each parameter to capture changes in each experimental phase from baseline, we also examined the trend of differences between the value of each feature at a specific experimental stage and that measured at baseline. For Pin Group, interphase variations were referred to as “Δ1/2 Pin” and “Δ1/1 Pin,” while for Dof & Pin Group these were labeled as “ΔDof” and “ΔDof + Pin.” Variations in body surface parameters were then compared to those in invasive measures of repolarization.

Finally, to verify the agreement of each non-invasive parameter with EGM gradients of repolarization, a Bland-Altman (BA) plot for each BSPM index from all experimental phases was built as follows (Altman and Bland, 1999). After feature standardization, the difference between the examined T-wave marker and the reference invasive metric zD was displayed against their average zM. The mean bias was estimated as the average of all differences zD, to provide an estimate of the average discrepancy between methods. For the same purpose, we also determined the 95% limits of agreement (LoA) of the interval as a measure of confidence. The narrower the interval, and the higher the number of points within it, the higher the degree of agreement between the compared approaches. Confidence bounds were corrected for repeated measures’ data, assuming that the true difference value is not constant across observations as in Altman and Bland (1999).

Results

Pin Group

Time evolution of EGM- and BSPM-derived parameters for each experiment from Pin Group is shown in Figure 2.

FIGURE 2
www.frontiersin.org

Figure 2. Time evolution of signal features and their variations with respect to baseline conditions for experiments from Pin Group, computed before and during progressive injection with pinacidil. (A) Invasive epicardial metrics of heterogeneity of repolarization and changes from baseline computed as global differences in RTs between Pin- and not-Pin sites (RTGGLOBAL and ΔRTGGLOBAL, left), global differences in RTs between LV and RV (RTG(LV/RV)GLOBAL and ΔRTG(LV/RV)GLOBAL, middle), and local RT gradients between neighboring epicardial sock nodes (RTGLOCAL and ΔRTGLOCAL, right). (B) BSPM indices and changes from baseline of T-wave duration (TPEAK-TEND and ΔTPEAK-TEND, left) and corrected QT interval (QTC and ΔQTC, right). (C) BSPM indices and changes from baseline of temporal variability of T-wave duration [SD(TPEAK-TEND) and ΔSD(TPEAK-TEND), left] and QTC spatial dispersion (QTD and ΔQTD, right). (D) BSPM indices and changes from baseline of T-wave symmetry (Asy and ΔAsy, left) and shape (dLV/RV and ΔdLV/RV, right). (E) BSPM indices and changes from baseline of T-wave complexity (CR and ΔCR, left, and NMSE and ΔNMSE, right). a.u., arbitrary units.

More pronounced differences in electrical recovery timing between perfused and non-perfused regions are globally measured by an increase in RTGGLOBAL in all experiments, except for experiment #3 (Figure 2A, left). Pinacidil injection is also responsible for a marked increase in EGM interventricular RT dispersion RTG(LV/RV)GLOBAL in experiments #1 and #2 (Figure 2A, middle), whereas RTs become more similar with time in experiment #3. Similar dynamics can be locally retrieved, with higher regional dispersion of repolarization and higher RTGLOCAL in all experiments #1 and #2 during drug injection, although with a more blunted evolution in experiment #3.

As shown in Figure 2B (left), the evolution of TPEAK-TEND on body surface is consistent with the trend of all epicardial measures of dispersion, namely, an increase in the duration of the ending portion of T-wave can be observed when repolarization is more heterogeneous. Regarding experiment #3, TPEAK-TEND prolongation is more pronounced when pinacidil injection has started, and then a drop in the index can be observed, with a time evolution resembling more that of global invasive markers of repolarization dispersion (RTGGLOBAL and RTG(LV/RV)GLOBAL) rather than regional measures (RTGLOCAL). On the other hand, a progressive shortening of QTC duration is observed during pinacidil perfusion throughout all interventions (Figure 2B, right), a behavior that has been reported by several experimental studies (Padrini et al., 1992; Extramiana and Antzelevitch, 2004), but in opposition to the time evolution of invasive markers of repolarization dispersion (except for RTGLOCAL in experiment #3).

The SD(TPEAK-TEND) index measures increasing temporal variability of TPEAK-TEND in all experiments (Figure 2C, right), but with transient fluctuations in parameter values in experiments #1 and #2 that do not always reflect the evolution of EGM metrics when low doses of pinacidil are administered. For experiment #3, temporal increase SD(TPEAK-TEND) does not match the decreasing trend of global markers of epicardial dispersion, while it better captures changes in local recovery heterogeneity RTGLOCAL. Overall, changes between the beginning and the end of all interventions ΔSD(TPEAK-TEND) are similar to that of the invasive counterparts, thus confirming that enhanced repolarization dispersion at the level of tissue reflects on a less stable temporal distribution of TPEAK-TEND duration on body surface. Spatial dispersion of QTc (QTD) is overall stable in experiments #1 and #2 (Figure 2C, left), while a marked, unexpected increase in QTD is measured during experiment #3, which is in disagreement with all invasive global metrics of dispersion. The same trends were observed without heart rate correction (results not shown).

As reported in Figure 2D (left), at baseline T-waves are usually left-skewed, and this characteristic is exacerbated by the introduction of global and regional repolarization gradients in experiments #1 and #2. Concerning experiment #3, T-waves also tend to be more left-skewed since the beginning of the intervention and keep a stable shape in time, as global and interventricular RT gradients from EGMs become more homogeneous. Overall, higher heterogeneity of repolarization seems to be associated with more asymmetric T-waves on body surface, in contrast to previous studies (Di Bernardo and Murray, 2000).

Interventricular differences in T-wave morphology between right and left BSPM electrodes according to DTW processing appear overall modest (Figure 2D, right). Drug-induced changes in repolarization properties significantly enhance such differences and lead to an increase in DTW distance dLV/RV only in experiment #2, and this is invasively confirmed by an increase in RT(LV/RV)GLOBAL during pinacidil injection, and by the other epicardial metrics as well. On the contrary, during the other interventions the index tends to have a stable trend, and changes between the initial and the final steps of the experiments are limited, in spite of a marked increase in EGM interventricular RT dispersion.

Unlike previous works (Priori et al., 1997), unexpected patterns of electrical organization are revealed by the dominant PCA spatial direction at low doses of pinacidil, with a drop in CR values when starting the perfusion (Figure 2E, left). At the final drug state, CR values are again comparable to those measured at baseline in all hearts. Similarly, body surface analysis of repolarization complexity according to the NMSE parameter in Figure 2E (right) also highlights some variability in its temporal evolution and absolute values across the interventions. In addition, changes in the parameter values from baseline ΔNMSE are modest. Taken together, these findings indicate that the accuracy of T-wave projection onto low-dimension spaces is quite variable and somehow difficult to link with the trend of the reference EGM metrics in this framework.

The agreement between T-wave markers and measures of epicardial RT dispersion is assessed by BA plots in Figure 3.

FIGURE 3
www.frontiersin.org

Figure 3. BA plots of the differences zD between BSPM markers of T-wave and invasive RT dispersion measures vs. their mean zM for the assessment of the agreement between the two approaches for experiments from Pin Group before and during progressive injection with pinacidil. The mean difference between methods (horizontal continuous black line) and upper and lower 95% LoA (dashed magenta and green lines, respectively) are also displayed. (A) BSPM indices and T-wave duration (TPEAK-TEND, left) and corrected QT interval (QTC, right). (B) BSPM indices of temporal variability of T-wave duration [SD(TPEAK-TEND), left] and QTC spatial dispersion (QTD, right). (C) BSPM indices of T-wave symmetry (Asy, left) and shape (dLV/RV, right). (D) BSPM indices of T-wave complexity (CR, left, and NMSE, right). a.u., arbitrary units.

For all T-wave indices, mean difference between non-invasive and invasive analysis (horizontal black line) is close to zero and points are quite scattered above and below zero, suggesting that there is no systematic bias (i.e., the error between BSPM- and EGM-derived parameters zD does not present any specific trend). The TPEAK-TEND index (Figure 3A, left) is overall highly consistent both with global (RTGGLOBAL) and local descriptors (RTGLOCAL) of repolarization heterogeneity, as the difference zD between the measures derived from invasive and non-invasive approaches tends to zero and the band of agreement (LoA) is quite narrow. With regard to the analysis of interventricular dispersion [RTG(LV/RV)GLOBAL], scatter points associated with experiment #3 tend to depart from the line zD = 0, but they are still within the LoA bounds. BA analysis of QT interval (Figure 3A, right) highlights that points associated with low QTC values (i.e., late experimental stages) are close to zero, regardless of the EGM marker, whereas longer QTC characterize points which lie farther from this threshold, although no specific trend can be elucidated from this distribution. Furthermore, the large width of the confidence interval denotes lower certainty with regard to the relation with epicardial RT dispersion at each scale of observation. In Figure 3B (left) BA plots for SD(TPEAK-TEND) confirm good agreement with all measures of RT gradients, especially with that of global dispersion RTGGLOBAL, with zD values nearly equal to zero and well separated point clusters (points associated with experiments #1 and #2 are well separated from those related to experiment #3). Similar remarks can be done for the regional analysis of heterogeneity through RTGLOCAL, but with zD values closer to zero for experiment #3, suggesting that in this heart local dispersion of ventricular recovery was better captured by this index than in the global analysis. The ability to distinguish between distinct drug states is lost when considering spatial dispersion of duration QTD (Figure 3B, right), with most of zD points far from zero and a large LoA interval. The relation between T-wave morphology and epicardial RT heterogeneity is displayed in Figure 3C. For the Asy index (left panel), BA plot demonstrates accurate agreement with regional and global dispersion of repolarization, and measures acquired from different experiments (i.e., #1 and #2) at the same phase tend to cluster around zD = 0. Measures related to experiment #3 also follow well global EGM metrics, and they are distributed far from each other along zD = 0. Also, the bounds of the interval of agreement are quite narrow. The scatterplots for the dLV/RV index in in Figure 3C (right) are more scattered, but at acceptable distance from the zero-threshold and comparable agreement with all EGM parameters. Finally, BA analysis of T-wave complexity according to the CR and NMSE indices (Figure 3D, left and right panel, respectively) denotes even lower agreement with invasive RT dispersion, as confirmed by the quite large LoA interval and zD distribution, with most of the points far from zero.

Dof & Pin Group

The same analysis has been repeated for all experiments from Dof & Pin Group, and the trend of invasive and non-invasive descriptors of ventricular repolarization is reported in Figure 4.

FIGURE 4
www.frontiersin.org

Figure 4. Time evolution of signal features and their variations with respect to baseline conditions for experiments from Dof & Pin Group, computed before and during progressive injection with dofetilide and pinacidil. (A) Invasive epicardial metrics of heterogeneity of repolarization and changes from baseline computed as global differences in RTs between Pin- and not-Pin sites (RTGGLOBAL and ΔRTGGLOBAL, left), global differences in RTs between LV and RV (RTG(LV/RV)GLOBAL and ΔRTG(LV/RV)GLOBAL, middle), and local RT gradients between neighboring epicardial sock nodes (RTGLOCAL and ΔRTGLOCAL, right). (B) BSPM indices and changes from baseline of T-wave duration (TPEAK-TEND and ΔTPEAK-TEND, left) and corrected QT interval (QTC and ΔQTC, right). (C) BSPM indices and changes from baseline of temporal variability of T-wave duration [SD(TPEAK-TEND) and ΔSD(TPEAK-TEND), left] and QTC spatial dispersion (QTD and ΔQTD, right). (D) BSPM indices and changes from baseline of T-wave symmetry (Asy and ΔAsy, left) and shape (dLV/RV and ΔdLV/RV, right). (E) BSPM indices and changes from baseline of T-wave complexity (CR and ΔCR, left, and NMSE and ΔNMSE, right). a.u., arbitrary units.

In all experiments the injection of dofetilide has favored the onset of global and regional electrical disparities, which are further accentuated by the perfusion with pinacidil later in each experiment. These effects are correctly captured by all EGM metrics (Figure 4A), and they are overall stronger than in the setup of Pin Group, due to the combined and opposite effect of the two drugs on the duration of the recovery time.

As for Pin Group, an increasing evolution of TPEAK-TEND with the course of time also characterizes experiments from Dof & Pin Group and accurately follows changes in repolarization properties as measured at the level of the epicardium (Figure 4B, left). QTc index can also describe electrical recovery alterations (Figure 4B, right), although its variations over time are less abrupt than for TPEAK-TEND and pinacidil injection seems to have little effect compared with the previous drug state.

Likewise, an increase in temporal variability in the duration of the final portion of T-wave is described by an increase in SD(TPEAK-TEND), which is more evident when both drugs are injected (except for experiment #4, where pinacidil has little effect on the index) (Figure 4C, left). Trends of SD(TPEAK-TEND) and its changes from baseline ΔSD(TPEAK-TEND) closely reflect the appearance of repolarization gradients through pharmacological approach as confirmed by the corresponding evolution of all epicardial measures of RT dispersion with the course of the experiments. Conversely, drug-induced changes in repolarization heterogeneity were not captured by QTD (Figure 4C, right), whose values at the end of the perfusion of both drugs were comparable with those measured at baseline, with and without heart rate normalization, and with high variability in its values across the interventions when only dofetilide is injected.

In this set of interventions, T-wave morphology is significantly affected during drug perfusion. Globally, T-wave shape tends to be more triangular/trapezoidal, the ascending slope is steeper and a notched pattern can be frequently observed from BSPMs (see Figure 1), compared with Pin Group, at baseline T-waves are either left-skewed or symmetric, with average values of Asy inferior to unity (Figure 4D, left). Subsequently, late repolarization is prolonged by the injection of dofetilide, thus durations of the starting and final portions are less similar to each other. These differences are further exacerbated by the injection of pinacidil, which drastically shortens the duration of early repolarization and causes a strong increase in Asy values. Time evolution of this body surface marker and its changes from baseline closely reflect the trend of the epicardial repolarization dispersion.

Drug-induced repolarization gradients are also responsible for more pronounced differences in T-wave shape between left and right BSPM electrodes according to DTW analysis. As shown in Figure 4D (right), a lower degree of similarity between waveforms from left and right side of the torso tank is assessed by DTW during dofetilide perfusion for all interventions, and it is in keeping with the evolution of all EGM measures of RT dispersion. Interventricular differences in T-wave patterns are further emphasized by the injection of pinacidil later in both experiments, and confirmed by EGM analysis.

As for the previous set of interventions, the evolution of PCA-derived features in Figure 4E is affected by strong inter-experiment variability, although our findings seem to support the idea that overall higher heterogeneity of the ventricular recovery is better described by low-rank approximations of cardiac repolarization. In all experiments, lower PCA reconstruction errors and a sharp decrease in the CR index are measured during dofetilide perfusion. A further (although more modest) drop in this parameter is observed when adding pinacidil, except for experiment #3. According to NMSE analysis, a decline in spatial complexity with time can be easily appreciated for experiment #2, whereas the other ones are characterized by modest changes from baseline and weak agreement with invasive assessment of repolarization gradients.

In Figure 5, BA plots for all BSPM parameters are reported. As for Pin Group, mean bias is negligible for all indices. However, dispersion of point distribution is globally lower than in Pin Group, with zD values close to zero and no specific pattern in relation to zM. Specifically, in Figure 5A (left), the relation between TPEAK-TEND and global and local descriptors of epicardial RT dispersion is displayed. Overall, experimental measures from different phases are even better separated from each other along the zM horizontal axis than in Pin Group, and their variability at a given phase is low, especially when compared to RTGGLOBAL and RTGLOCAL. Moreover, the LoA interval is quite narrow for all scatterplots, hinting at good agreement with invasive RT gradient metrics, regardless of the scale of observation. Conversely, with regard to QT interval analysis (Figure 5A, right), while the interval of agreement has similar bounds and baseline zD difference values (left side of the scatterplot) tend to zero, then with progressive drug administration their distribution appears more scattered around the mean bias, and measures acquired at different drug states tend to form a unique cluster, denoting a lack of sensitivity of the QTC index and poor discrimination of different drug states (e.g., different degrees of RT heterogeneity). Similar remarks can be done for the indices of variability of body surface repolarization duration (Figure 5B), with SD(TPEAK-TEND) (left panel) exhibiting closer agreement with all invasive RT gradient parameters at each experimental phase than QTD (right panel). Taken together, these findings suggest that the T-wave final portion is more informative than QT interval with regard to the characterization of distinct levels of repolarization heterogeneity. BA plots for T-wave shape parameters are shown in Figure 5C. T-wave asymmetry (left panel) and interventricular DTW distance (right panel) are both more consistent with EGM reference indices than their counterparts from Pin Group, as denoted by all quasi-null zD values, and confidence intervals are quite tight. Of note, Asy values from the same experimental phase tend to form definite clusters, thus denoting lower measure uncertainty and easier phase discrimination than fordLV/RV, in particular when compared to RTGGLOBAL and RTGLOCAL. Finally, in Figure 5D BA scatterplots for PCA descriptors of spatial complexity are presented. As for Pin Group, the LoA width is larger compared with the other BSPM parameters. Furthermore, point distribution is extremely scattered and BSPM measures associated with distinct intervention steps are difficult to distinguish, with most of zD values far from zero, hinting at a weaker relation with epicardial RT dispersion, regardless of the metric considered.

FIGURE 5
www.frontiersin.org

Figure 5. BA plots of the differences zD between BSPM markers of T-wave and invasive RT dispersion measures vs. their mean zM for the assessment of the agreement between the two approaches for experiments from Dof & Pin Group before and during progressive injection with dofetilide and pinacidil. The mean difference between methods (horizontal continuous black line) and upper and lower 95% LoA (dashed magenta and green lines, respectively) are also displayed. (A) BSPM indices and T-wave duration (TPEAK-TEND, left) and corrected QT interval (QTC, right). (B) BSPM indices of temporal variability of T-wave duration [SD(TPEAK-TEND), left] and QTC spatial dispersion (QTD, right). (C) BSPM indices of T-wave symmetry (Asy, left) and shape (dLV/RV, right). (D) BSPM indices of T-wave complexity (CR, left, and NMSE, right). a.u., arbitrary units.

Discussion

In this study, we have compared state-of-the-art and novel parameters for the non-invasive assessment of the degree of cardiac repolarization dispersion from BSPMs. The use of an ex vivo torso tank model allowed us to test all metrics in a controlled environment and get rid of confounding factors that are typically encountered in vivo, e.g., respiration movement, use of anesthetics and lack of control on the mechanisms underlying a certain pathology. Importantly, this model helped us to reproduce global and local repolarization abnormalities due to purely electrical phenomena, which is crucial to understand electrical disorders which may affect structurally normal hearts. In addition, simultaneous invasive mapping of repolarization has enabled a better understanding of the relation between drug-induced changes in repolarization at the level of the tissue and manifestations of these phenomena on body surface as reflected on T-wave characteristics.

T-Wave Duration and Dispersion of Repolarization

As in previous studies, we usually observed a prolongation of the duration of the TPEAK-TEND interval when repolarization gradients were created by drug perfusion. Changes in this index have been thought to reflect alterations in transmural dispersion of repolarization (Yan and Antzelevitch, 1998), and be prognostic of arrhythmic risk under a variety of conditions (Antzelevitch et al., 2007). Nevertheless, the ability of TPEAK-TEND interval to provide an absolute measure of transmural dispersion in vivo is still under debate (Xia et al., 2005), and other studies have supported the idea that this index may rather be a predictor of arrhythmogenesis as the result of increased global dispersion of ventricular recovery (Opthof et al., 2007). Even though we could not fully clarify the precise mechanisms behind this electrocardiographic manifestation (we could not perform endocardial mapping), our findings show that a higher degree of both global and local repolarization heterogeneity subsequent to drug intervention reflects on the lengthening of the terminal part of T-wave on the torso tank. This behavior has also been validated by BA plot analysis, and showed strong consistency with similar formulations for epicardial RT dispersion. In only one case (experiment 3 from Pin Group) a shortening of this interval was measured from EGMs after pinacidil injection. This may be potentially explained by a delayed effect of the drug, which was actually visible only during drug washout (not shown). Concerning the QT interval, different behaviors have been observed depending on the experimental setup. The sole administration of pinacidil in Pin Group caused a shortening of the QTC interval, in line with previous studies (Padrini et al., 1992; Extramiana and Antzelevitch, 2004) reporting this ECG feature as a consequence of higher transmural dispersion of repolarization. On the contrary, the use of dofetilide led to QTC prolongation, which may be proarrhythmic (Barrett et al., 2001). Overall, increased epicardial dispersion of repolarization, both local and global, was not reflected by a consistent behavior of QT interval on body surface, thus confirming the lack of specificity of this index, which reflects both the depolarization and repolarization process, thus to be interpreted with caution.

T-Wave Duration Variability and Dispersion of Repolarization

Exacerbation of repolarization gradients was responsible for enhanced beat-to-beat variability of TPEAK-TEND duration. This phenomenon has been previously related to increased arrhythmic risk both clinically and experimentally (Pueyo et al., 2011; Piccirillo et al., 2013). Results from computational studies have corroborated the critical role of IKs and IKr currents in the temporal modulation of repolarization reserve at the cellular level, both in physiological and pathological conditions (Pueyo et al., 2011). In Piccirillo et al. (2013), temporal myocardial repolarization lability was associated with increased risk for SCD and also potentially correlated with a downregulation of potassium currents, which is typical of patients with congestive heart failure. Importantly, as argued by the same authors, temporal instability of TPEAK-TEND duration may be indicative of the presence of tissue areas containing non-homogeneous refractory periods, and under favorable conditions (e.g., ischemia) the recovery of excitability may lag behind the completion of repolarization as well (Burton and Cobbe, 2001). Although the exact cellular mechanisms could not be elucidated by our investigation, in line with these studies, we also observed that a decline in temporal stability of TPEAK-TEND duration during drug perfusion precisely followed changes in RT dispersion on the sock and showed good agreement with the reference invasive metrics, and this phenomenon was observed in all experiments. On the contrary, regional electrical disparities were not accurately identified by the QTD index, whose capability of assessing repolarization heterogeneity has been questioned by previous studies as well (Malik et al., 2000; Prenner et al., 2016). Indeed, QT interval is insensitive to shortening of regional repolarization in the presence of prolonged repolarization elsewhere (Burton and Cobbe, 2001) and its variability is likely the result of the different projections of the heart vector on the body surface, rather than true dispersion of repolarization (Di Bernardo et al., 2000; Malik et al., 2000; Burton and Cobbe, 2001).

T-Wave Morphology and Dispersion of Repolarization

Overall, abnormal dispersion of electrical recovery strongly affected the morphology of T-wave. In our dataset, a decline in T-wave symmetry was found to be associated with higher dispersion of repolarization. This is in contrast to results from simulations presented by Di Bernardo and Murray (2000), who found that T-wave became more symmetrical with increased apico-basal and transmural dispersion. However, other studies presented opposite findings (Van Huysduynen et al., 2005; Vicente et al., 2015), and this may be due to the use of a non-realistic torso-heart model, with too simple geometries, and the lack of granularity in the modulation of action potential initiation at different sites (Di Bernardo and Murray, 2000). In contrast, electrocardiographic manifestations reported by our investigation are closer to those presented by Vicente et al. (2015), although alterations in T-wave profile presented in that study were provoked by other drugs acting on different ionic channels. In our experience, repolarization gradients led to a progressive loss of T-wave symmetry in all experiments, as a result of a steeper T-wave upslope and marked changes in the terminal portion of T-wave, both in terms of duration and area, with strong agreement with invasive measures of dispersion of repolarization. This effect was even clearer during experiments from Dof & Pin Group when both drugs were simultaneously injected, probably because differences between early and late repolarizing sites were more emphasized by the combined use of dofetilide and pinacidil rather than the injection of pinacidil alone and were easier to retrieve on body surface.

According to DTW, creation of repolarization gradients through pharmacological approach highlighted stronger differences in T-wave shape between left and right BSPM electrodes with respect to baseline. Morphological aberrations of T-wave profile as a consequence of repolarization inhomogeneity have been previously documented (Vicente et al., 2015; Ramirez et al., 2017), but mechanisms underlying such alterations are still unclear. Abnormal T-wave patterns have been observed during dofetilide-induced long QT syndrome (type 2) by Meijborg et al. (2015), who reported a correlation between increased interventricular dispersion of repolarization and appearance of notched waveforms on ECG, although shape assessment was rather qualitative. Alterations in ECG T-wave upslope have also been attributed to increased right-to-left RT dispersion from human hearts (Srinivasan et al., 2019). In Ramirez et al. (2017) DTW processing of T-wave accurately assessed risk for SCD in a population of congestive heart failure patients, although that retrospective study was more focused on temporal changes of T-wave rather than spatial aspects. Our research proposed a potential application of DTW processing as a descriptor of T-wave abnormalities in relation to dispersion of repolarization, and its capability of detecting variations in T-wave shape across leads. Interventricular differences in T-wave patterns were easier to appreciate in all experiments from Dof & Pin Group when both drugs were simultaneously injected, as for the Asy index. This finding is also confirmed by BA plot, which is characterized by narrower interval of agreement than in Pin Group and quasi-null zD values, thus confirming good agreement with evidence from invasive recordings.

T-Wave Complexity and Dispersion of Repolarization

PCA has proved to be a suitable tool for the description of cardiac activity from body surface, with prognostic value in SCD prediction (Porthan et al., 2013). Previous studies showed that T-wave non-dipolar components assessed by PCA are associated with increased dispersion of repolarization in a multitude of pathologies (De Ambroggi et al., 1997; Priori et al., 1997). Surprisingly, an inverse correlation between spatiotemporal organization of T-wave and repolarization uniformity was underlined by our analysis, albeit with some variability across the experiments. This unusual result is in line with (Zabel et al., 2000), showing that lower PCA ratios are predictive of post-myocardial infarction arrhythmic events, although with borderline statistical significance. The observed phenomenon may be due to an intrinsic limitation of our ex vivo model, as when we inject drug(s) in and outside the LAD artery we artificially create two distinct clusters with distinct recovery timings, with a steep transition at their border. This scenario is simpler than in vivo repolarizing tissue, where each myocardial cell differently contributes to the global behavior of the heart, therefore it may be more easily and accurately captured by low-rank PCA approximations rather than in the absence of drugs. Another potential explanation for this phenomenon may come from Van Oosterom’s T-wave model (Sassi and Mainardi, 2011; Laguna et al., 2016), which assumes surface T-wave genesis as the result of the counteraction between spatial distribution of RTs across the ventricular tissue and changes in the AP repolarization profile at the level of the single cardiomyocyte in a PCA-based framework. Indeed, according to Van Oosterom’s formulation, in substrates with increased heterogeneity of repolarization, at each time instant t surface T-wave y(t) can be decomposed into a weighted sum of a function Td (also called the dominant T-wave) and its derivative T.d:

Y ( t ) w 1 T d + w 2 T . d - A Δ ρ d . ( t - ρ ¯ ) + 1 2 Δ ρ 2 d . ( t - ρ ¯ )

With the weights w1 = −AΔρ and w2=12Δρ2 dependent on RT dispersion Δρ across the tissue, A a transfer matrix, d(t-ρ¯) describing the repolarization phase of the transmembrane potentials of the myocytes of a given region, and ρ¯ equal to the spatial average of local RTs over that region. As illustrated in Laguna et al. (2016), the unknown Td and T.d functions can be estimated by SVD of the input BSPM matrix Y as:

T d = c 1 σ 1 v 1 T , w 1 = u 1 c 1
T . d = c 2 σ 2 v 2 T , w 2 = u 2 c 2

Where c1 and c2 are scalar constants which can be computed under suitable constraints (Sassi and Mainardi, 2011). This theoretical framework clarifies the simultaneous dependence of the second singular value σ2 on RT dispersion Δρ and on the AP downstroke velocity (t-ρ¯), which may explain (at least in part) the unexpected trend of PCA features during drug injection. Specifically, in Pin Group the increased spatial heterogeneity of repolarization Δρwith progressive infusion of pinacidil is accompanied by KATP channel opening, causing shorter APD and steeper downstroke (t-ρ¯) (Fedorov et al., 2011). However, this action is not strong enough to induce a significant change in spatial complexity of T-wave, maybe because a relatively small area (the LAD coronary) is affected by this intervention, thus drug-induced changes in repolarization cannot be correctly captured by high-order PCA approximations, and in particular by the spatial direction u2. Conversely, in Dof & Pin Group, the injection of dofetilide in extra-LAD regions may have caused a more marked reduction in AP downslope velocity (t-ρ¯) compared with RT spatial dispersion Δρ (Vicente et al., 2015), with a stronger effect likely due to the involvement of a higher number of ventricular sites, and partial restoration of the initial conditions during pinacidil injection. Furthermore, other factors may contribute to the complexity of myocardium electrical recovery in vivo, including autonomic modulation (Ghuran et al., 2000) or ischemia (Al-Zaiti et al., 2011). To our knowledge, this is the first application of PCA to T-wave analysis in an experimental model, as it has been so far performed only in clinical human patients, with comparisons with invasive measures from explanted hearts performed only indirectly (Zabel et al., 1995). Further investigation is needed to clarify this divergence between experimental and clinical findings.

Limitations and Perspectives

The study was performed on a limited number of hearts, thus the proposed BSPM markers should be tested on a larger dataset to corroborate their descriptive accuracy. However, evolution of BSPM indices was overall consistent across experiments, and deviations from expected trends were linked to experimental conditions (e.g., delayed drug effect, tissue block etc.).

Paucity of data may also have affected the outcome of the BA analysis of signal features, and in particular with respect to the width of confidence intervals and the impossibility to perform a statistical comparison over such a low number of samples. Nevertheless, most of BSPM indices demonstrated good agreement with all indices of epicardial dispersion of repolarization, thus proving that physiologically relevant information about repolarization alterations can be inferred by body surface T-wave analysis at multiple observation scales.

Although the spatial resolution of the signal processing framework presented in this study is not sufficiently high to clearly distinguish different mechanisms of recovery dispersion from body surface and/or localize tissue areas with abnormal timing, the proposed techniques can overall help to non-invasively detect repolarization abnormalities by exclusively exploiting the information provided by BSPMs, with no need for patient’s anatomy, requiring the use of more expensive imaging technologies. On the contrary, these tools could be used to detect repolarization anomalies at a larger scale of observation and potentially complement other approaches (e.g., electrocardiographic imaging or contact mapping) to identify diseased ventricular sites with higher precision at a second stage.

Body surface markers for repolarization variability were compared and validated with global and regional measures of epicardial RT gradients. Although reliable, as they straightforwardly account for tissue local properties, these measures should be interpreted with caution. Indeed, the computation of RT-dependent metrics may be affected by experimental maneuvers (e.g., loss of sock electrode contact during LAD cannulation). Additionally, the examined parameters only allow us to describe what happens on the epicardium, thus any unexplained behavior of RT gradient measures may be potentially influenced by other phenomena, either endocardial or transmural. To address this question, in a subset of two hearts from Pin Group (Experiments #2 and #3) we recorded transmural potentials through 8 plunge needles (four electrodes, 3 mm spacing) and we measured the average of the epi-to-endo RT gradients over four needles (two in LAD region, two in the posterior interventricular artery area). Changes in transmural dispersion of repolarization over time were either limited (Experiment #2: Baseline 28 ± 25 ms vs. 1/2 Pin 24 ± 25 ms vs. 1/1 Pin 19 ± 22 ms, repeated-measures one-way ANOVA p = 0.05) or absent (Experiment #3: Baseline 20 ± 14 ms vs. 1/2 Pin 20 ± 14 ms vs. 1/1 Pin 20 ± 11 ms, p = 0.82). Transmural needle mapping has not been performed on the other hearts due not only this weak evidence, but also to its technical challenges, e.g., the risk for myocardial damage and potential onset of ischemia that could have compromised the accomplishment of the experiments. Furthermore, the low number of needle probes and their uneven positioning were likely responsible for the variability of these results across the experiments and the impossibility to give even a preliminary interpretation of the absence/presence of epi-endo dissociation. As a consequence, future works may rather envisage the inclusion of simultaneous endocardial mapping (e.g., with a basket catheter) to explore additional mechanisms beyond epicardial repolarization heterogeneity more systematically.

Future research may include the comparison with other invasive features (e.g., from intracardiac or optical mapping), to better elucidate the mechanisms underlying body surface manifestations of repolarization dispersion, as well as their direction. For the same purpose, the use of in silico models may help validating BSPM features and possibly link them to specific mechanisms at lower scale.

In both datasets, drug injection provoked marked repolarization gradients, both globally at the level of the whole organ and locally between neighboring, smaller sites, and all examined BSPM parameters exhibited a consistent relation with regional and global invasive RT dispersion gradients. A potential perspective of this research may envision the inclusion of models with different interventions (e.g., to create sharp local/global repolarization gradients with globally/locally homogeneous repolarization, as it partially happened during experiment #3 from Pin Group) to investigate whether and how these forms of electrical unevenness selectively affect body surface potentials.

As explained in section 2, in keeping with (Cabasson and Meste, 2008), a fixed-length search window has been used for all electrodes to detect T-wave offset. While the range of values chosen has allowed for the segmentation of the entire T-wave with no spurious truncation in most of the BSPM leads, in other electrodes the time occurrence of T-wave end may have been slightly overestimated, with some impact on T-wave duration parameters. To overcome this issue, incorrect TOFF time locations were usually fixed after visual inspection when possible, and our analysis confirmed that shifted detections did not affect significantly differences in duration between distinct drug states and explanted hearts.

Measures of QT interval duration and dispersion have been adjusted for heart rate using Bazett’s equation, in spite of the lack of a clear consensus on the use of this formula for porcine models. To overcome this limitation, we also analyzed uncorrected values of QT duration and spatial variability, and we concluded that their time evolution was independent of heart rate, which is expected to be stable in explanted perfused hearts.

With regard to PCA assessment of T-wave, in this document we report a detailed analysis of only two PCA-derived indices, although we have investigated a larger number of PCA markers of T-wave from the state-of-the-art (e.g., the relative T-wave spatial residuum, T-wave planarity, total cosine R-to-T; Merri et al., 1989; Malik et al., 2000; Korhonen et al., 2009; Porthan et al., 2013), and evaluated their ability to measure repolarization heterogeneity in our database when using between one and three principal components. In line with the findings presented in section “2.3.4,” all indices were characterized by an unexpected inverse correlation between T-wave complexity and ventricular recovery dispersion, therefore we considered it appropriate to include a few of them in this report to avoid redundancy. Moreover, as stated above, to clarify whether and how changes in AP downslope and cell-to-cell coupling affect PCA eigenvalues’ extraction during drug injection, meaningful insights could be provided by computational models of cardiac repolarization at the single myocyte level, which may help exploring mechanisms at a lower scale than our epicardial sock (Laguna et al., 2016).

In this work propensity to ventricular arrhythmias was not systematically explored, as we mainly investigated how substrate-dependent repolarization abnormalities reflected on T-wave properties rather than those trigger-related. Preliminary research from our group on a similar dataset has shown that arrhythmia susceptibility is strongly influenced both by the trigger location and timing, but also by the properties of the underlying substrate (Bear et al., 2019b), and that in vulnerable hearts T-waves are longer, flatter and more asymmetric (Meo et al., 2020). However, the potential of electrocardiographic features as a tool for arrhythmogenesis assessment in this model deserves further investigation.

Finally, a systematic comparison with T-wave features from an equivalent 12-lead ECG could not be performed, as in most of the experiments electrodes with noisy/low voltage signals were located close to lead III and precordial leads (especially V5-V6) and removed. This may also be object of future investigation, for potential translation of the proposed T-wave analysis tools into clinical routine, where standard ECG is more commonly used.

Conclusion

This study investigated performance of several indices for the non-invasive assessment of different mechanisms of dispersion of ventricular repolarization from BSPMs. Our findings confirm that pathological alterations of cardiac recovery can be studied from body surface, and that a more detailed assessment of such aberrations can be obtained only if we look at multiple properties of T-wave, including duration, morphology and spatiotemporal organization. This research opens promising perspectives in the characterization of repolarization abnormalities, with potential applicability to clinical electrocardiology.

Data Availability Statement

The raw data supporting the conclusions of this article will be made available by the authors, upon reasonable request. Requests to access the datasets should be directed to laura.bear@ihu-liryc.fr. A subset of the experimental data will be made available for the electrocardiographic imaging community, through the EDGAR project (http://www.ecg-imaging.org/), a collaborative effort by the Consortium for ECG Imaging.

Ethics Statement

The animal study was reviewed and approved by the Directive 2010/63/EU of the European Parliament on the protection of animals used for scientific purposes and the local ethical committee.

Author Contributions

MM conceived and designed the study, implemented the signal processing methods, analyzed and interpreted the results, and drafted the manuscript. PB equally contributed to the implementation of the study, methodological considerations, interpretation of results, and manuscript revision. LB and MC designed and performed the experiments, and provided insights into the interpretation of the results. EA also helped with experimental data acquisition. MH and OB provided feedback on the outcome of the study from a clinical and mechanistic point of view, respectively. RD helped with the conception of the study, provided feedback about the implementation of the methods and the interpretation of the results, and revised the manuscript. All authors have significantly contributed to this work.

Funding

This study was supported by the French Government as part of the “Investments of the Future” program managed by the National Agency Research (ANR-10-IAHU04-LIRYC), and the Leducq transatlantic network of excellence RHYTHM transatlantic network (16CVD02).

Conflict of Interest

MC was part-time employed by Philips Research.

The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Abbreviations

APD, action potential duration; BA, Bland-Altman; BSPM, body surface potential map; CR, complexity of repolarization; Dof, dofetilide; DTW, dynamic time warping; ECG, electrocardiogram; EGM, electrogram; FIR, finite impulse response; LAD, left anterior descending; LoA, limit of agreement; LV, left ventricle; NMSE, normalized mean square error; Pin, pinacidil; PCA, principal component analysis; RT, repolarization time; RTG, repolarization time gradient; RV, right ventricle; SCD, sudden cardiac death.

References

Altman, D. G., and Bland, J. M. (1999). Measuring agreement in method comparison studies. Stat. Methods Med. Res. 8, 135–160. doi: 10.1191/096228099673819272

CrossRef Full Text | Google Scholar

Al-Zaiti, S. S., Runco, K. N., and Carey, M. G. (2011). Increased T wave complexity can indicate subclinical myocardial ischemia in asymptomatic adults. J. Electrocardiol. 44, 684–688. doi: 10.1016/j.jelectrocard.2011.07.017

PubMed Abstract | CrossRef Full Text | Google Scholar

Antzelevitch, C. (2001). Tpeak-Tend interval as an index of transmural dispersion of repolarization. Eur. J. Clin. Invest. 31, 555–557. doi: 10.1046/j.1365-2362.2001.00849.x

PubMed Abstract | CrossRef Full Text | Google Scholar

Antzelevitch, C. (2007). Heterogeneity and cardiac arrhythmias: an overview. Heart Rhythm 4, 964–972. doi: 10.1016/j.hrthm.2007.03.036

PubMed Abstract | CrossRef Full Text | Google Scholar

Antzelevitch, C., Shimizu, W., Yan, G. X., Sicouri, S., Weissenburger, J., Nesterenko, V. V., et al. (1999). The M cell: its contribution to the ECG and to normal and abnormal electrical function of the heart. J. Cardiovasc. Electrophysiol. 10, 1124–1152. doi: 10.1111/j.1540-8167.1999.tb00287.x

PubMed Abstract | CrossRef Full Text | Google Scholar

Antzelevitch, C., Sicouri, S., Di Diego, J. M., Burashnikov, A., Viskin, S., Shimizu, W., et al. (2007). Does Tpeak-Tend provide an index of transmural dispersion of repolarization? Heart Rhythm 4, 1114–1116; author reply 1116–1119.

Google Scholar

Barrett, T. D., Hennan, J. K., Fischbach, P. S., O’Neill, B. P., Driscoll, E. M., and Lucchesi, B. R. (2001). Tedisamil and dofetilide-induced torsades de pointes, rate and potassium dependence. Br. J. Pharmacol. 132, 1493–1500. doi: 10.1038/sj.bjp.0703967

PubMed Abstract | CrossRef Full Text | Google Scholar

Baumert, M., Porta, A., Vos, M. A., Malik, M., Couderc, J. P., Laguna, P., et al. (2016). QT interval variability in body surface ECG: measurement, physiological basis, and clinical value: position statement and consensus guidance endorsed by the European heart rhythm association jointly with the ESC working group on cardiac cellular electroph. Europace 18, 925–944. doi: 10.1093/europace/euv405

PubMed Abstract | CrossRef Full Text | Google Scholar

Bear, L. R., Bouhamama, O., Cluitmans, M., Duchateau, J., Walton, R. D., Abell, E., et al. (2019a). Advantages and pitfalls of noninvasive electrocardiographic imaging. J. Electrocardiol. 57S, S15–S20.

Google Scholar

Bear, L. R., Cluitmans, M., Abell, E., Belterman, C., Roger, J., Labrousse, L., et al. (2019b). A novel index to predict the ventricular locations associated with arrhythmia vulnerability. Heart Rhythm Soc. Congress 5S, S426–S521, doi: 10.1016/j.hrthm.2019.04.018

CrossRef Full Text | Google Scholar

Bear, L. R., Walton, R. D., Abell, E., Coudière, Y., Haissaguerre, M., Bernus, O., et al. (2019c). Optical imaging of ventricular action potentials in a torso tank: a new platform for non-invasive electrocardiographic imaging validation. Front. Physiol. 10:146. doi: 10.3389/fphys.2019.00146

PubMed Abstract | CrossRef Full Text | Google Scholar

Bonizzi, P., De La Salud Guillem, M., Climent, A. M., Millet, J., Zarzoso, V., Castells, F., et al. (2010). Noninvasive assessment of the complexity and stationarity of the atrial wavefront patterns during atrial fibrillation. IEEE Trans. Biomed. Eng. 57, 2147–2157. doi: 10.1109/tbme.2010.2052619

PubMed Abstract | CrossRef Full Text | Google Scholar

Burnes, J. E., Ghanem, R. N., Waldo, A. L., and Rudy, Y. (2001). Imaging dispersion of myocardial repolarization, I: comparison of body-surface and epicardial measures. Circulation 104, 1299–1305. doi: 10.1161/hc3601.094276

PubMed Abstract | CrossRef Full Text | Google Scholar

Burton, F. L., and Cobbe, S. M. (2001). Dispersion of ventricular repolarization and refractory period. Cardiovasc. Res. 50, 10–23. doi: 10.1016/s0008-6363(01)00197-3

CrossRef Full Text | Google Scholar

Cabasson, A., and Meste, O. (2008). Time delay estimation: a new insight into the Woody’s method. IEEE Signal Process. Lett. 15, 573–576. doi: 10.1109/lsp.2008.2001558

CrossRef Full Text | Google Scholar

De Ambroggi, L., Aimè, E., Ceriotti, C., Rovida, M., and Negroni, S. (1997). Mapping of ventricular repolarization potentials in patients with arrhythmogenic right ventricular dysplasia: principal component analysis of the ST-T waves. Circulation 96, 4314–4318. doi: 10.1161/01.cir.96.12.4314

CrossRef Full Text | Google Scholar

Di Bernardo, D., Langley, P., and Murray, A. (2000). Dispersion of QT intervals: a measure of dispersion of repolarization or simply a projection effect? Pacing Clin. Electrophysiol. 23, 1392–1396. doi: 10.1111/j.1540-8159.2000.tb00968.x

PubMed Abstract | CrossRef Full Text | Google Scholar

Di Bernardo, D., and Murray, A. (2000). Explaining the T-wave shape in the ECG. Nature 403:40. doi: 10.1038/47409

PubMed Abstract | CrossRef Full Text | Google Scholar

Extramiana, F., and Antzelevitch, C. (2004). Amplified transmural dispersion of repolarization as the basis for arrhythmogenesis in a canine ventricular-wedge model of short-QT syndrome. Circulation 110, 3661–3666. doi: 10.1161/01.cir.0000143078.48699.0c

CrossRef Full Text | Google Scholar

Fedorov, V., Glukhov, A., Ambrosi, C., Kostecki, G., Chang, R., Janks, D., et al. (2011). Effects of KATP channel openers diazoxide and pinacidil in coronary-perfused atria and ventricles from failing and non-failing human hearts. J. Mol. Cell. Cardiol. 51, 215–225. doi: 10.1016/j.yjmcc.2011.04.016

PubMed Abstract | CrossRef Full Text | Google Scholar

Fish, J. M., Di Diego, J. M., Nesterenko, V., and Antzelevitch, C. (2004). Epicardial activation of left ventricular wall prolongs QT interval and transmural dispersion of repolarization: implications for biventricular pacing. Circulation 109, 2136–2142. doi: 10.1161/01.cir.0000127423.75608.a4

CrossRef Full Text | Google Scholar

Fuller, M. S., Sándor, G., Punske, B., Taccardi, B., MacLeod, R. S., Ershler, P. R., et al. (2000). Estimates of repolarization dispersion from electrocardiographic measurements. Circulation 102, 685–691. doi: 10.1161/01.cir.102.6.685

CrossRef Full Text | Google Scholar

Ghuran, A., Batchvarov, V., Dilaveris, P., Färbom, P., Camm, A. J., and Malik, M. (2000). Reflex autonomic modulation of automatically measured repolarization parameters. Pacing Clin. Electrophysiol. 23, 1973–1976. doi: 10.1111/j.1540-8159.2000.tb07065.x

PubMed Abstract | CrossRef Full Text | Google Scholar

Hlaing, T., Guo, D., Zhao, X., DiMino, T., Greenspon, L., Kowey, P. R., et al. (2005). The QT and Tp-e intervals in left and right chest leads: comparison between patients with systemic and pulmonary hypertension. J. Electrocardiol. 38, 154–158. doi: 10.1016/j.jelectrocard.2005.06.028

PubMed Abstract | CrossRef Full Text | Google Scholar

Holt, J. H., Barnard, C. L., Lynn, M. S., and Svendsen, P. (1969). A study of the human heart as a multiple dipole electrical source in normal adult male subjects. Circulation 40, 687–696. doi: 10.1161/01.cir.40.5.687

CrossRef Full Text | Google Scholar

Korhonen, P., Husa, T., Konttila, T., Tierala, I., Mäkijärvi, M., Väänänen, H., et al. (2009). Complex T-wave morphology in body surface potential mapping in prediction of arrhythmic events in patients with acute myocardial infarction and cardiac dysfunction. Europace 11, 514–520. doi: 10.1093/europace/eup051

PubMed Abstract | CrossRef Full Text | Google Scholar

Laguna, P., Martinez Cortes, J. P., and Pueyo, E. (2016). Techniques for Ventricular repolarization instability assessment from the ECG. Proc. IEEE 104, 392–415. doi: 10.1109/jproc.2015.2500501

CrossRef Full Text | Google Scholar

Malik, M., Acar, B., Gang, Y. I., Yap, Y. G., Hnatkova, K., and John Camm, A. (2000). QT dispersion does not represent electrocardiographic interlead heterogeneity of ventricular repolarization. J. Cardiovasc. Electrophysiol. 11, 835–843. doi: 10.1111/j.1540-8167.2000.tb00061.x

PubMed Abstract | CrossRef Full Text | Google Scholar

Marill, K. A., Dorsey, P., Holmes, A., Muthal, K., Miller, E. S., and Xue, J. (2018). Is myocardial repolarization duration associated with repolarization heterogeneity? Ann. Noninvasive Electrocardiol. 23:e12519. doi: 10.1111/anec.12519

PubMed Abstract | CrossRef Full Text | Google Scholar

Meijborg, V. M. F., Chauveau, S., Janse, M. J., Anyukhovsky, E. P., Danilo, P. R., Rosen, M. R., et al. (2015). Interventricular dispersion in repolarization causes bifid T waves in dogs with dofetilide-induced long QT syndrome. Heart Rhythm 12, 1343–1351. doi: 10.1016/j.hrthm.2015.02.026

PubMed Abstract | CrossRef Full Text | Google Scholar

Meo, M., Bonizzi, P., Bear, L., Cluitmans, M., Abell, E., Haïssaguerre, M., et al. (2020). Relation of surface T-wave to vulnerability to ventricular fibrillation in explanted structurally normal hearts. Comput. Cardiol. (in press).

Google Scholar

Meo, M., Zarzoso, V., Meste, O., Latcu, D. G., and Saoudi, N. (2013). Catheter ablation outcome prediction in persistent atrial fibrillation using weighted principal component analysis. Biomed. Signal Process. Control 8, 958–968. doi: 10.1016/j.bspc.2013.02.002

CrossRef Full Text | Google Scholar

Merri, M., Benhorin, J., and Alberti, M. (1989). Electrocardiographic quantitation of heterogeneity of ventricular repolarization. Circulation 80, 1301–1308. doi: 10.1161/01.cir.80.5.1301

CrossRef Full Text | Google Scholar

Müller, M. (ed.). (2007). “Dynamic time warping,” in Information Retrieval for Music and Motion, (Berlin: Springer), 69–84.

Google Scholar

Nygårds, M. E., and Sörnmo, L. (1983). Delineation of the QRS complex using the envelope of the e.c.g. Med. Biol. Eng. Comput. 21, 538–547. doi: 10.1007/bf02442378

PubMed Abstract | CrossRef Full Text | Google Scholar

Okin, P. M., Devereux, R. B., Fabsitz, R. R., Lee, E. T., Galloway, J. M., and Howard, B. V. (2002). Principal component analysis of the T wave and prediction of cardiovascular mortality in American Indians: the strong heart study. Circulation 105, 714–719. doi: 10.1161/hc0602.103585

PubMed Abstract | CrossRef Full Text | Google Scholar

Opthof, T., Coronel, R., Wilms-Schopman, F. J. G., Plotnikov, A. N., Shlapakova, I. N., Danilo, P., et al. (2007). Dispersion of repolarization in canine ventricle and the electrocardiographic T wave: Tp-e interval does not reflect transmural dispersion. Heart Rhythm 4, 341–348. doi: 10.1016/j.hrthm.2006.11.022

PubMed Abstract | CrossRef Full Text | Google Scholar

Padrini, R., Bova, S., Cargnelli, G., Piovan, D., and Ferrari, M. (1992). Effects of pinacidil on guinea-pig isolated perfused heart with particular reference to the proarrhythmic effect. Br. J. Pharmacol. 105, 715–719. doi: 10.1111/j.1476-5381.1992.tb09044.x

PubMed Abstract | CrossRef Full Text | Google Scholar

Peeters, H. A. P., Sippensgroenewegen, A., Wever, E. F. D., Grimbergen, C. A., Hauer, R. N. W., and Medina, E. O. R. D. E. (1998). Electrocardiographic identification of abnormal ventricular depolarization and repolarization in patients with idiopathic ventricular fibrillation. J. Am. Coll. Cardiol. 31, 1406–1413. doi: 10.1016/s0735-1097(98)00120-x

CrossRef Full Text | Google Scholar

Piccirillo, G., Rossi, P., Mitra, M., Quaglione, R., Dell’Armi, A., Di Barba, D., et al. (2013). Indexes of temporal myocardial repolarization dispersion and sudden cardiac death in heart failure: any difference? Ann. Noninvasive Electrocardiol. 18, 130–139. doi: 10.1111/anec.12005

PubMed Abstract | CrossRef Full Text | Google Scholar

Porthan, K., Viitasalo, M., Toivonen, L., Havulinna, A. S., Jula, A., Tikkanen, J. T., et al. (2013). Predictive value of electrocardiographic T-wave morphology parameters and T-wave peak to T-wave end interval for sudden cardiac death in the general population. Circulation 6, 690–696. doi: 10.1161/circep.113.000356

PubMed Abstract | CrossRef Full Text | Google Scholar

Prenner, S. B., Shah, S. J., Goldberger, J. J., and Sauer, A. J. (2016). Repolarization heterogeneity: beyond the QT interval. J. Am. Heart Assoc. 5:e003607.

Google Scholar

Priori, S. G., Mortara, D. W., Napolitano, C., Diehl, L., Paganini, V., Cantù, F., et al. (1997). Evaluation of the spatial aspects of T-wave complexity in the long-QT syndrome. Circulation 96, 3006–3012. doi: 10.1161/01.cir.96.9.3006

CrossRef Full Text | Google Scholar

Pueyo, E., Corrias, A., Virág, L., Jost, N., Szél, T., Varró, A., et al. (2011). A multiscale investigation of repolarization variability and its role in cardiac arrhythmogenesis. Biophys. J. 101, 2892–2902. doi: 10.1016/j.bpj.2011.09.060

PubMed Abstract | CrossRef Full Text | Google Scholar

Ramirez, J., Orini, M., Mincholé, A., Monasterio, V., Cygankiewicz, I., de Luna, A. B., et al. (2017). T-wave morphology restitution predicts sudden cardiac death in patients with chronic heart failure. J. Am. Heart Assoc. 6:e005310.

Google Scholar

Sassi, R., and Mainardi, L. T. (2011). An estimate of the dispersion of repolarization times based on a biophysical model of the ECG. IEEE Trans. Biomed. Eng 58, 3396–3405. doi: 10.1109/tbme.2011.2166263

PubMed Abstract | CrossRef Full Text | Google Scholar

Sheridan, P. J., Marques, J. L. B., Newman, C. M. H., Heller, S. R., and Clayton, R. H. (2010). Rate-dependent measures of repolarization predict inducibility of ventricular arrhythmias. Europace 12, 553–560. doi: 10.1093/europace/euq024

PubMed Abstract | CrossRef Full Text | Google Scholar

Smetana, P., Schmidt, A., Zabel, M., Hnatkova, K., Franz, M., Huber, K., et al. (2011). Assessment of repolarization heterogeneity for prediction of mortality in cardiovascular disease: peak to the end of the T wave interval and nondipolar repolarization components. J. Electrocardiol. 44, 301–308. doi: 10.1016/j.jelectrocard.2011.03.004

PubMed Abstract | CrossRef Full Text | Google Scholar

Srinivasan, N. T., Orini, M., Providencia, R., Simon, R., Lowe, M., Segal, O. R., et al. (2019). Differences in the upslope of the precordial body surface ECG T wave reflect right to left dispersion of repolarization in the intact human heart. Heart Rhythm 16, 943–951. doi: 10.1016/j.hrthm.2018.12.006

PubMed Abstract | CrossRef Full Text | Google Scholar

Straus, S. M. J. M., Kors, J. A., De Bruin, M. L., Van Der Hooft, C. S., Hofman, A., Heeringa, J., et al. (2006). Prolonged QTc interval and risk of sudden cardiac death in a population of older adults. J. Am. Coll. Cardiol. 47, 362–367. doi: 10.1016/j.jacc.2005.08.067

PubMed Abstract | CrossRef Full Text | Google Scholar

Taccardi, B., Punske, B. B., Lux, R. L., MacLeod, R. S., Ershler, P. R., Dustma, T. J., et al. (2007). Useful lessons from body surface mapping. J. Cardiovasc. Electrophysiol. 9, 773–786. doi: 10.1111/j.1540-8167.1998.tb00965.x

PubMed Abstract | CrossRef Full Text | Google Scholar

Van Huysduynen, B. H., Swenne, C. A., Draisma, H. H. M., Antoni, M. L., Van De Vooren, H., Van Der Wall, E. E., et al. (2005). Validation of ECG indices of ventricular repolarization heterogeneity: a computer simulation study. J. Cardiovasc. Electrophysiol. 16, 1097–1103. doi: 10.1111/j.1540-8167.2005.40758.x

PubMed Abstract | CrossRef Full Text | Google Scholar

Vicente, J., Johannesen, L., Mason, J. W., Crumb, W. J., Pueyo, E., Stockbridge, N., et al. (2015). Comprehensive T wave morphology assessment in a randomized clinical study of dofetilide, quinidine, ranolazine, and verapamil. J. Am. Heart Assoc. 4:e001615.

Google Scholar

Vijayakumar, R., Silva, J. N. A., Desouza, K. A., Abraham, R. L., Strom, M., Sacher, F., et al. (2014). Electrophysiologic substrate in congenital long QT syndrome: noninvasive mapping with electrocardiographic imaging (ECGI). Circulation 130, 1936–1943. doi: 10.1161/circulationaha.114.011359

PubMed Abstract | CrossRef Full Text | Google Scholar

Vinzio Maggio, A. C., Paula, M., Laciar, E., and David, P. (2012). “Quantification of ventricular repolarization dispersion using digital processing of the surface ECG,” in Advances in Electrocardiograms - Methods and Analysis, ed. R. M. Millis (London: IntechOpen).

Google Scholar

Xia, Y., Liang, Y., Kongstad, O., Liao, Q., Holm, M., Olsson, B., et al. (2005). In vivo validation of the coincidence of the peak and end of the T wave with full repolarization of the epicardium and endocardium in swine. Heart Rhythm 2, 162–169. doi: 10.1016/j.hrthm.2004.11.011

PubMed Abstract | CrossRef Full Text | Google Scholar

Yan, G. X., and Antzelevitch, C. (1998). Cellular basis for the normal T wave and the electrocardiographic manifestations of the long-QT syndrome. Circulation 98, 1928–1936. doi: 10.1161/01.cir.98.18.1928

CrossRef Full Text | Google Scholar

Zabel, M., Acar, B., Klingenheben, T., Franz, M. R., Hohnloser, S. H., and Malik, M. (2000). Analysis of 12-lead T-wave morphology for risk stratification after myocardial infarction. Circulation 102, 1252–1257. doi: 10.1161/01.cir.102.11.1252

CrossRef Full Text | Google Scholar

Zabel, M., and Malik, M. (2001). Predictive value of T-wave morphology variables and QT dispersion for postmyocardial infarction risk assessment. J. Electrocardiol. 34, 27–35. doi: 10.1054/jelc.2001.28822

PubMed Abstract | CrossRef Full Text | Google Scholar

Zabel, M., Portnoy, S., and Franz, M. R. (1995). Electrocardiographic indexes of dispersion of ventricular repolarization: an isolated heart validation study. J. Am. Coll. Cardiol. 25, 746–752. doi: 10.1016/0735-1097(94)00446-w

CrossRef Full Text | Google Scholar

Zhang, J., Sacher, F., Hoffmayer, K., O’Hara, T., Strom, M., Cuculich, P., et al. (2015). Cardiac electrophysiological substrate underlying the ECG phenotype and electrogram abnormalities in brugada syndrome patients. Circulation 131, 1950–1959. doi: 10.1161/circulationaha.114.013698

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: sudden cardiac death, ventricular repolarization heterogeneity, body surface potential mapping, T-wave, electrocardiology

Citation: Meo M, Bonizzi P, Bear LR, Cluitmans M, Abell E, Haïssaguerre M, Bernus O and Dubois R (2020) Body Surface Mapping of Ventricular Repolarization Heterogeneity: An Ex-vivo Multiparameter Study. Front. Physiol. 11:933. doi: 10.3389/fphys.2020.00933

Received: 28 May 2020; Accepted: 10 July 2020;
Published: 13 August 2020.

Edited by:

Marek Malik, Imperial College London, United Kingdom

Reviewed by:

Pablo Laguna, University of Zaragoza, Spain
Gary Tse, Second Hospital of Tianjin Medical University, China

Copyright © 2020 Meo, Bonizzi, Bear, Cluitmans, Abell, Haïssaguerre, Bernus and Dubois. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Marianna Meo, bWFyaWFubmEubWVvQGlodS1saXJ5Yy5mcg==; bWFyaWFubmFtZW9AZ21haWwuY29t

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.