Skip to main content

ORIGINAL RESEARCH article

Front. Oncol., 27 September 2019
Sec. Radiation Oncology

Dosimetric Impact of Interfractional Variations in Prostate Cancer Radiotherapy—Implications for Imaging Frequency and Treatment Adaptation

\nTilman Bostel,,&#x;Tilman Bostel1,2,3Ilias Sachpazidis,&#x;Ilias Sachpazidis4,5Mona Splinter,Mona Splinter6,7Nina Bougatf,,Nina Bougatf1,2,6Tobias Fechter,Tobias Fechter4,5Constantinos Zamboglou,Constantinos Zamboglou4,5Oliver Jkel,Oliver Jäkel6,7Peter E. Huber,,Peter E. Huber1,2,6Dimos Baltas,Dimos Baltas4,5Jürgen Debus,,Jürgen Debus1,2,6Nils H. Nicolay,,
Nils H. Nicolay1,4,5*
  • 1Clinical Cooperation Unit “Radiation Oncology”, German Cancer Research Center, Heidelberg, Germany
  • 2Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
  • 3Department of Radiation Oncology, University Medical Center Mainz, Mainz, Germany
  • 4Department of Radiation Oncology, University of Freiburg Medical Center, Freiburg, Germany
  • 5German Cancer Consortium (DKTK), Partner Site Freiburg, German Cancer Research Center, Heidelberg, Germany
  • 6Heidelberg Institute of Radiation Oncology, National Center for Radiation Research in Oncology, Heidelberg, Germany
  • 7Medical Physics in Radiation Oncology, German Cancer Research Center, Heidelberg, Germany

Background and purpose: To analyze deviations of the applied from the planned doses on a voxel-by-voxel basis for definitive prostate cancer radiotherapy depending on anatomic variations and imaging frequency.

Materials and methods: Daily in-room CT imaging was performed in treatment position for 10 patients with prostate cancer undergoing intensity-modulated radiotherapy (340 fraction CTs). Applied fraction doses were recalculated on daily images, and voxel-wise dose accumulation was performed using a deformable registration algorithm. For weekly imaging, weekly position correction vectors were derived and used to rigidly register daily scans of that week to the planning CT scan prior to dose accumulation. Applied and prescribed doses were compared in dependence of the imaging frequency, and derived TCP and NTCP values were calculated.

Results: Daily CT-based repositioning resulted in non-significant deviations of all analyzed dose-volume, conformity and uniformity parameters to the CTV, bladder and rectum irrespective of anatomic changes. Derived average TCP values were comparable, and NTCP values for the applied doses to the bladder and rectum did not significantly deviate from the planned values. For weekly imaging, the applied D2 to the CTV, rectum and bladder significantly varied from the planned doses, and the CTV conformity index and D98 decreased. While TCP values were comparable, the NTCP for the bladder erroneously appeared reduced for weekly repositioning.

Conclusions: Based on daily diagnostic quality CT imaging and voxel-wise dose accumulation, we demonstrated for the first time that daily, but not weekly imaging resulted in only negligible deviations of the applied from the planned doses for prostate intensity-modulated radiotherapy. Therefore, weekly imaging may not be adequately reliable for adaptive treatment delivery techniques for prostate. This work will contribute to devising adaptive re-planning strategies for prostate radiotherapy.

Introduction

Prostate cancer is among the most prevalent malignant diseases in men with between 100 and 170 newly diagnosed patients per 100,000 people annually (1). Radiotherapy is one of the mainstays of prostate cancer therapy, and several large analyses have suggested outcomes comparable to surgical tumor removal while resulting in favorable toxicities in the surrounding organs-at risk (24). The use of intensity-modulated radiotherapy (IMRT) has been shown to reduce late radiation-induced genitourinary and gastrointestinal toxicities, thereby enabling the safe application of higher treatment doses (5, 6). However, the advent of high-precision radiotherapy for prostate cancer has made the treatment application more susceptible to inaccuracies due to changes in the pelvic anatomy, and the occurrence of intra- and especially interfractional variations of the prostate and the surrounding organs-at risk have been well studied (79). Regular image guidance using cone-beam CT (CBCT) is set to reduce inaccuracies in dose application due to anatomic changes; nevertheless, the validity of the anatomic information is somewhat hampered by the weak soft tissue contrast of pelvic CBCT imaging and may require additional means of patient position control like implanted fiducials. The implications of interfractional variations on the applied radiotherapy doses are less well understood. Previous work using weekly CT scans and rigid registration demonstrated significant deviations from the prescribed dose for both IMRT and proton radiotherapy (10, 11). More recent work using elastic imaging registration reported no clinically relevant aberrations of the applied doses from the doses prescribed during a prospective study; however, this analysis relied on weekly imaging and CBCT-based dose accumulation (12).

Here, we quantified interfractional anatomic variations and calculated resulting deviations of the applied from the planned doses using daily planning CT scans performed for positional verification in treatment position as part of the daily radiotherapy algorithm. Additionally, the impact of the frequency of position control imaging on the applied radiation doses was studied. This work will contribute to devising adaptive re-planning strategies for prostate radiotherapy.

Materials and Methods

Patient Selection

Ten consecutive patients receiving definitive prostate radiotherapy at the German Cancer Research Center were included in this analysis. All patients presented with low or intermediate-risk prostate cancer with stage T1c to T2b disease, Gleason scores not exceeding 7 and PSA values ranging below 20 ng/ml (13). This study is in accordance with the Declaration of Helsinki (Seventh Revision, 2013) and was approved by the Independent Ethics Committee of the Medical Faculty of the University of Heidelberg, Germany (S-380/2017).

Treatment Planning and Delivery

For all patients, the clinical target volume (CTV) comprised the prostate gland for low-risk tumors and additionally 10–15 mm of the proximal seminal vesicles for intermediate-risk cancers. A setup margin of 7 mm was added to the CTV to create a planning target volume (PTV). The prescribed dose was 76.50 Gy in 34 fractions of 2.25 Gy. Dose constraints to the organs-at risk (OAR) were based on the Quantitative Analyses of Normal Tissue Effects in the Clinic (1416). Patients were immobilized with a ProStep™ pelvic and lower extremity support (Elekta, Stockholm, Sweden), and were instructed to present to daily treatment with an empty bowel and a comfortably filled bladder. Treatment plans were generated using the RayStation planning system (RaySearch Laboratories, Stockholm, Sweden), and step-and-shoot IMRT was applied using 9 co-planar fields on an Artiste linear accelerator (Siemens, Erlangen, Germany).

Daily CT Imaging

Patients were positioned in treatment position on the treatment couch as described above, based on tattooed skin markers applied at the time of the planning CT and a calibrated 3D laser coordinate system. The treatment couch was then rotated into a CT scanner (Primatom; Siemens OCS, Malvern, USA) that was integrated into the linear accelerator setup and located at a 90° angle directly adjacent to the accelerator in the treatment room. Patients received daily diagnostic CT imaging in treatment position as position verification; the treatment couch was then re-rotated to the treatment gantry with no manipulation to the patient setup. The in-room CT scanner had been approved for treatment planning scans, and all scans were taken to the same specifications used for the individual planning examinations.

Analysis of Variations and Dose Accumulation

Target volumes and OARs were outlined by a board-certified radiation oncologist both on the planning CT scans and the daily position verification CT scans according to current contouring guidelines (17, 18). Daily fraction doses were recalculated on the corresponding daily images, and resulting dose distributions were transferred onto the planning scans. Voxel-wise dose accumulation was carried out in RayStation using the software's deformable image registration module and compared to the planned dose distribution (19). Daily imaging was rigidly registered to the planning CT scans prior to dose re-calculation as done for routine patient repositioning. For simulated weekly imaging, position correction vectors were derived from the CT scans of days 1, 6, 11, 16, 21, 26, and 31 and used to rigidly register the five daily scans of each treatment week to the planning CT scan. Applied and planned 3D dose distributions were compared using dose-volume indices, including mean dose (Dmean), doses at × % volume (Dx) and volume at x Gy doses (Vx). The conformity-related indices, conformity index (CI) and conformal index (COIN) for the total prescription dose, and the uniformity parameters gEUD and gEUD2Gy were also considered for comparison purposes (see Annex I in Supplementary Material) (20, 21). In addition, the tumor control probability (TCP) and normal tissue complication probabilities (NTCP) for the relevant OARs and the complication-free tumor control probability (P+), were calculated and considered for the analysis (see Annex II in Supplementary Material).

Finally, the applied dose distributions were compared within the region receiving >10% of the maximum dose by 3D-gamma analysis to the clinical tolerance level of 3%/3 mm (22).

Statistical Analysis

Statistical analysis of the differences in dose volume indices between planned and applied doses was performed by Wilcoxon signed-rank test with corresponding two-sided confidence intervals using in-house software developed in Python (https://www.python.org). An alpha level of 0.05 was used for all statistical tests.

Results

Anatomic Variations

Patients exhibited distinct anatomic changes during the course of radiotherapy. While the pre-treatment CTVs ranged between 37.5 and 168.0 ml for analyzed patients, the volumes remained stable throughout therapy with a relative volume difference between the planning examination and the treatment scans of 0.3 ± 10.9% (Figure 1, Supplementary Figure 1). Rectal volumes were measured between 36.4 and 112.4 ml at treatment planning and increased by an average of 9.8 ± 32.3% during treatment (Supplementary Figure 1). As expected, the bladder volumes exhibited the biggest variability, ranging between 71.5 and 530.4 ml on the planning CT scan; however, the average difference to the bladder volumes during treatment was only 1.3 ± 22.2%. Regarding individual patients, considerable differences in rectal and bladder filling during treatment were observed. To assess potential implications of the described anatomic changes on the position of the CTV, its geometric center was compared between the planning scan and the daily scans after individual rigid pre-treatment realignments based on adjacent bony structures. The average lateral CTV displacement in the lateral X direction amounted to 0.3 ± 0.3 mm (fractional range: −0.2 to 0.9 mm), and there were only small effects observed for daily treatment fractions or individual patients (individual range −0.6 to 0.9 mm) (Figure 2, Supplementary Figure 2). Changes in the superior-inferior Y direction amounted to an average of 0.4 ± 0.7 mm (fractional range: −1.5 to 2.1 mm) with considerably more inter-individual variability (individual range −2.0 to 4.1 mm). Similarly, the anterior-posterior CTV displacement resulted in an average shift of −0.6 ± 0.7 mm (fractional range −1.6 to 1.5 mm) with strong differences for individual patients (individual range −4.7 to 4.9 mm). Due to the defined PTV margin of 7 mm, daily pre-treatment analysis of position verification CTs did not warrant treatment adaptation or re-planning for any patient based on interfractional variability.

FIGURE 1
www.frontiersin.org

Figure 1. Relative volumes of the CTV, rectum and bladder of each patient during the course of radiotherapy compared to the planning CT-based volumes. Error bars represent standard deviation.

FIGURE 2
www.frontiersin.org

Figure 2. Relative deviation of the geometric center of the CTV between the planning CT and the fractional CTs in all three dimensions and resulting total displacement for each patient included in this analysis. Error bars represent standard deviation.

Influence of Anatomic Variations on Dose Distribution

Applied doses were compared with the planned doses to the CTV, bladder and rectum (Figure 3). As expected from the volumetric analyses, the bladder demonstrated the highest variability between planned and applied doses, and the deviations for bladder and rectum were strongest in the high dose range (Figure 4). Table 1 summarizes the differences in the dose-volume indices between planned and accumulated doses. For the CTV, the strongest deviations were seen for D98 with an average reduction of 2.27 Gy for the accumulated dose; in contrast, the accumulated average Dmean and D2 deviated by only −0.08 and −0.40 Gy from the prescribed doses, respectively. No significant differences in the gEUD and gEUD2Gy, the conformity indices or the probability of complication-free tumor control (P+) could be observed between treatment plans and applied doses.

FIGURE 3
www.frontiersin.org

Figure 3. Representative CT slices demonstrating the planned and applied doses using daily or weekly CT-based repositioning.

FIGURE 4
www.frontiersin.org

Figure 4. Summary dose-volume histograms for the CTV (blue line), rectum (red line) and bladder (green line) for treatment plans (upper panel) and accumulated doses after daily (middle panel) and weekly (lower panel) repositioning. Lighter-colored bands represent the 95% confidence interval of each dose-volume curve.

TABLE 1
www.frontiersin.org

Table 1. Average and standard deviation of differences between applied and planned dose-volume indices for daily or weekly CT-based repositioning.

The accumulated average Dmean to the rectum was only 0.14 ± 3.73 Gy higher than planned, and all dose-volume indices did not show significant deviations from the treatment plan. Considering the considerable volume changes for the bladder, the applied Dmean was on average 2.78 ± 5.88 Gy higher than initially planned. However, all dosimetric values for the bladder also varied only insignificantly, and the mean dose-volume parameters were highly comparable between planned and accumulated doses. Similarly, EUD-based comparison including gEUD and gEUD2Gy did not show any significant differences for the rectum or bladder. The median prostate TCP values were 93.16% (min. 93.05%, max. 93.33%) for the planned dose and 93.5% (min. 87.48%, max. 93.9%) for the applied dose with no significant deviation (p = 0.759) (Figure 5). Similarly, NTCP values resulting from the accumulated and the planned doses were highly comparable, and no significant differences were found for the bladder (p = 0.683) or the rectum (p = 0.475). P+ values were also comparable between planned and applied doses (p = 0.308).

FIGURE 5
www.frontiersin.org

Figure 5. Box-plot diagrams for TCP, bladder and rectal NTCP and P+ values derived from the planned and accumulated doses.

Dosimetric Impact of Daily vs. Weekly Positioning Imaging

To evaluate the dosimetric impact of daily vs. weekly position verification CT, correction vectors from the first positioning scan of each treatment block (fractions 1, 6, 11, 16, 21, 26, and 31) were used to rigidly register all consecutive weekly CTs to the planning scan, and applied doses were accumulated and compared to accumulated doses resulting from daily CT-based repositioning. The largest deviations from the planned dose-volume indices were observed in the high dose range, with the D2 significantly lower for the CTV (−0.83 ± 0.90 Gy; p = 0.040), the bladder (−4.55 ± 8.48 Gy; p = 0.020) and the rectum (−2.04 ± 2.77 Gy; p = 0.020) (Figure 4, Table 1). Weekly repositioning also resulted in a significant decrease of the CTV conformity index compared to the planning data (−0.35 ± 0.42; p = 0.030) and a decrease in the D98 (−4.24 ± 6.00 Gy; p = 0.190), although the latter value did not reach statistical significance. There was also a trend toward increased median doses to the rectum (2.78 ± 4.10 Gy; p = 0.070) for weekly repositioning. TCP and P+ values were not significantly different between applied and planned doses irrespective of the repositioning frequency. Similarly, NTCP values for the rectum did not significantly deviate for the weekly or daily repositioning, while NTCP for the bladder was found lower when repositioning was only performed once a week (Figure 5). The gamma passing rate to the clinical tolerance level of 3%/3 mm was 3.2% lower for the weekly position verification imaging than that for the daily imaging (p = 0.042) (Figure 6).

FIGURE 6
www.frontiersin.org

Figure 6. Box-plot diagram for the gamma analyses regarding daily and weekly imaging.

Discussion

Intra- and inter-fractional anatomic variations have been a concern for prostate cancer radiotherapy, and the potential dosimetric consequences of these variations have been subject to intense research; however, studies have been hampered by the quality and frequency of positional imaging and the availability of sufficient image registration tools, and to the best of our knowledge, to date, no publications are available using CT-based daily voxel-wise dosimetric comparisons for intensity-modulated prostate radiotherapy. This dataset provides for the first time a comprehensive analysis of the dosimetric impact of interfractional variability using daily in-room planning-quality CT imaging, enabling adequate voxel-wise dose accumulation for the target volume and organs-at-risk over the course of intensity-modulated radiotherapy for each fraction and each patient. Our data demonstrated that daily CT-based repositioning resulted in only non-significant deviations of all analyzed dose-volume parameters to the CTV, bladder and rectum from the planned doses irrespective of anatomic changes in the bladder and rectal filling and position. In contrast, reliance on weekly position-verification imaging resulted in deviations especially for the high doses and significantly reduced dose conformity to the target volume. To the best of our knowledge, this is the first dataset utilizing daily diagnostic CT imaging and a deformable registration strategy to enable voxel-wise dose tracking for prostate cancer patients undergoing IMRT.

In the past, several strategies for the accumulation of the applied dose in prostate cancer radiotherapy have been reported for available CBCTs in order to overcome the limited usability of these low-quality images, including portal dose measurements, using enhanced CBCT with additional filters or rigid registration strategies with limited dose mapping potential (7, 12, 23, 24). To date, voxel-wise dosimetric analyses based on daily CTs are only available for proton radiotherapy; this may be due to a broader availability of diagnostic scanners in proton treatment facilities and the necessity of higher-quality imaging given the increased anatomy-dependent range uncertainties of protons (25). A previous report analyzing proton treatment data demonstrated significant lower dose in the PTV in 15 out of 225 analyzed treatment fractions, mostly caused by alterations in the rectal volume (26). In a second publication analyzing 10 patients undergoing proton radiotherapy, the V72.67 was above 95% for 90.4–98.7% of treatment fractions depending on the matching strategy (25). To our knowledge, similar high-quality data are not available for IMRT.

Considering the variable pelvic anatomy and the influence of bladder and rectal filling on the localization of the prostate, the ideal frequency of positional verification imaging has been subject to some debate, and several publications have analyzed dosimetric and clinical implications of daily vs. weekly imaging. A previous analysis based on CBCTs from 20 patients demonstrated improved target coverage and reductions of the V50, V65, and Dmean to the rectum with daily imaging, although no voxel-wise dose accumulation could be performed due to limitations in image quality and registration (27). Similar improvements of target coverage by daily imaging have been reported in other publications, and it has been suggested that PTV margins should be adjusted according to the imaging frequency (28). In our dataset, daily image-guided repositioning resulted in better target volume conformity and target volume coverage and a trend toward increased rectal doses. However, the impact of these dosimetric improvements for patients remains to be fully elucidated (29). To date, at least two prospective trials have investigated the clinical implications of daily CBCT for prostate cancer patients. In a French randomized study analyzing 470 men, daily imaging resulted in improved biochemical and clinical progression-free survival and reduced late rectal toxicity, while having an adverse correlation with patients' overall survival (30). A second randomized trial did not demonstrate any advantage regarding toxicities or patients' quality of life from daily CBCT and reduced PTV margins compared to weekly portal imaging (31).

The additional use of implanted fiducial markers for prostate radiotherapy may also impact potential deviations of the applied from the prescribed doses; however, it has been suggested that there are only minor deviations in the dose distribution between patients with and without markers if 3D imaging is performed daily (7). Using implanted markers, kV X-ray imaging is commonly used to replace daily CT imaging or to supplement weekly 3D imaging schedules, but does not show bladder and rectal anatomy and hence does not allow an assessment of dosimetric effects on these organs.

Future developments may help to decrease dosimetric deviations of prostate radiation treatments from treatment plans by optimizing repositioning: the advent of MR-linac and the opportunity for real-time MR-guided prostate tracking before and during each treatment fraction may enable adjustments of patient positions based on superior soft tissue contrast and may also help to minimize not only interfractional but also intrafractional motion (32, 33). Additionally, repositioning strategies have been proposed that utilize accumulated dosimetric information over the course of treatment for dose-guided patient repositioning (34). However, in our dataset, dosimetric deviations in all tested dose-volume parameters from the treatment plan were non-significant when daily 3D imaging was performed, making potential further benefits for the treated patients debatable.

Despite the high imaging quality and the comprehensive dosimetric information, there are limitations to our analysis. The number of patients included in this analysis was relatively small due to logistical reasons associated with the complex workflow, and the patient number may affect the statistical power. Additionally, dose deviations may not only depend on interfractional setup errors, but also on intrafractional prostate motion which could not be taken into account for our data. Additionally, all patients included in our analysis were coached about bladder and rectal filling and also received feedback based on their imaging results on all days the bladder or rectal filling deviated considerably from the planning CT. The resulting relative consistency in bladder and rectal anatomy in all analyzed patients may be a key reason for the moderate dosimetric effects of our simulated weekly repositioning analysis, and patients may in reality exhibit considerably higher dose deviations in case of weekly imaging. Simulating weekly imaging by utilizing every fifth CT scan (weekly treatment block) was based on routine clinical imaging schedules for prostate cancer patients; however, it may potentially introduce a bias as this methodology only provides an anatomic snap-shot that may not be representative for other simulated non-daily imaging schedules.

The relevance of our findings for high-risk or locally advanced prostate cancers and prostatic bed irradiation will require further investigations, as different treatment margins for these scenarios will likely affect dose-volume parameters.

Nevertheless, our dataset provides a novel in-depth and voxel-wise analysis of the dosimetric effects of interfractional variations in prostate cancer radiotherapy based on a comprehensive dataset of daily high-quality CTs that may have implications for the frequency of verification imaging and may help to guide strategies for adaptive radiotherapy planning.

Conclusion

Despite considerable variations in the position and volume of bladder and rectum, daily in-room CT-based rigid patient repositioning resulted in only negligible deviations of applied doses from planned doses for prostate radiotherapy. In contrast, voxel-wise dose accumulation analyses demonstrated significant divergences in the high dose range and a reduction of dose conformity to the target volume in case of weekly CT-based position verification. This indicates for the first time on a voxel-based level that a reduced imaging frequency may not be adequately reliable for adaptive treatment delivery techniques for intensity-modulated prostate radiotherapy. This work will contribute to devising adaptive re-planning strategies for prostate radiotherapy.

Data Availability Statement

The datasets generated for this study will not be made publicly available. These are patient-individual data that are protected by German laws and cannot be distributed without explicit written consent by every included patient.

Ethics Statement

This study was carried out in accordance with the recommendations of name of guidelines, name of committee with written informed consent from all subjects. All subjects gave written informed consent in accordance with the Declaration of Helsinki. The protocol was approved by the approved by the Independent Ethics Committee of the Medical Faculty of the University of Heidelberg, Germany (S-380/2017).

Author Contributions

TB, PH, JD, and NN planned and carried out treatment. TB, IS, MS, TF, CZ, NB, OJ, DB, and NN analyzed data. NN wrote the manuscript. IS, PH, and DB helped with writing the manuscript. JD helped with data discussion.

Conflict of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Supplementary Material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fonc.2019.00940/full#supplementary-material

Supplementary Figure 1. Mean relative volumes of the CTV, rectum and bladder for each treatment fraction compared to the planning CT-based volumes. Error bars represent standard deviation.

Supplementary Figure 2. Relative deviation of the geometric center of the CTV between the planning CT and fractional CTs in X, Y, and Z direction (A) and resulting total displacement (B) for each treatment fraction. Error bars represent standard deviation.

References

1. Torre LA, Siegel RL, Ward EM, Jemal A. Global cancer incidence and mortality rates and trends–an update. Cancer Epidemiol Biomarkers Prev. (2016) 25:16–27. doi: 10.1158/1055-9965.EPI-15-0578

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Hamdy FC, Donovan JL, Lane JA, Mason M, Metcalfe C, Holding P, et al. 10-year outcomes after monitoring, surgery, or radiotherapy for localized prostate cancer. N Engl J Med. (2016) 375:1415–24. doi: 10.1056/NEJMoa1606220

CrossRef Full Text | Google Scholar

3. Kupelian PA, Potters L, Khuntia D, Ciezki JP, Reddy CA, Reuther AM, et al. Radical prostatectomy, external beam radiotherapy <72 Gy, external beam radiotherapy > or = 72 Gy, permanent seed implantation, or combined seeds/external beam radiotherapy for stage T1-T2 prostate cancer. Int J Radiat Oncol Biol Phys. (2004) 58:25–33. doi: 10.1016/S0360-3016(03)00784-3

CrossRef Full Text | Google Scholar

4. Resnick MJ, Koyama T, Fan KH, Albertsen PC, Goodman M, Hamilton AS, et al. Long-term functional outcomes after treatment for localized prostate cancer. N Engl J Med. (2013) 368:436–45. doi: 10.1056/NEJMoa1209978

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Viani GA, Viana BS, Martin JE, Rossi BT, Zuliani G, Stefano EJ. Intensity-modulated radiotherapy reduces toxicity with similar biochemical control compared with 3-dimensional conformal radiotherapy for prostate cancer: a randomized clinical trial. Cancer. (2016) 122:2004–11. doi: 10.1002/cncr.29983

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Bruner DW, Hunt D, Michalski JM, Bosch WR, Galvin JM, Amin M, et al. Preliminary patient-reported outcomes analysis of 3-dimensional radiation therapy versus intensity-modulated radiation therapy on the high-dose arm of the Radiation Therapy Oncology Group (RTOG) 0126 prostate cancer trial. Cancer. (2015) 121:2422–30. doi: 10.1002/cncr.29362

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Wust P, Joswig M, Graf R, Bohmer D, Beck M, Barelkowski T, et al. Dosimetric implications of inter- and intrafractional prostate positioning errors during tomotherapy: Comparison of gold marker-based registrations with native MVCT. Strahlenther Onkol. (2017) 193:700–6. doi: 10.1007/s00066-017-1141-x

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Verma V, Chen S, Zhou S, Enke CA, Wahl AO. Prostate bed target interfractional motion using RTOG consensus definitions and daily CT on rails: does target motion differ between superior and inferior portions of the clinical target volume? Strahlenther Onkol. (2017) 193:38–45 doi: 10.1007/s00066-016-1077-6

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Bylund KC, Bayouth JE, Smith MC, Hass AC, Bhatia SK, Buatti JM. Analysis of interfraction prostate motion using megavoltage cone beam computed tomography. Int J Radiat Oncol Biol Phys. (2008) 72:949–56. doi: 10.1016/j.ijrobp.2008.07.002

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Zhang X, Dong L, Lee AK, Cox JD, Kuban DA, Zhu RX, et al. Effect of anatomic motion on proton therapy dose distributions in prostate cancer treatment. Int J Radiat Oncol Biol Phys. (2007) 67:620–9. doi: 10.1016/j.ijrobp.2006.10.008

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Soukup M, Sohn M, Yan D, Liang J, Alber M. Study of robustness of IMPT and IMRT for prostate cancer against organ movement. Int J Radiat Oncol Biol Phys. (2009) 75:941–9. doi: 10.1016/j.ijrobp.2009.04.032

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Moteabbed M, Trofimov A, Sharp GC, Wang Y, Zietman AL, Efstathiou JA, et al. A prospective comparison of the effects of interfractional variations on proton therapy and intensity modulated radiation therapy for prostate cancer. Int J Radiat Oncol Biol Phys. (2016) 95:444–53. doi: 10.1016/j.ijrobp.2015.12.366

PubMed Abstract | CrossRef Full Text | Google Scholar

13. D'Amico AV, Whittington R, Malkowicz SB, Schultz D, Blank K, Broderick GA, et al. Biochemical outcome after radical prostatectomy, external beam radiation therapy, or interstitial radiation therapy for clinically localized prostate cancer. JAMA. (1998) 280:969–74. doi: 10.1001/jama.280.11.969

CrossRef Full Text | Google Scholar

14. Viswanathan AN, Yorke ED, Marks LB, Eifel PJ, Shipley WU. Radiation dose-volume effects of the urinary bladder. Int J Radiat Oncol Biol Phys. (2010) 76(3 Suppl.):S116–22. doi: 10.1016/j.ijrobp.2009.02.090

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Michalski JM, Gay H, Jackson A, Tucker SL, Deasy JO. Radiation dose-volume effects in radiation-induced rectal injury. Int J Radiat Oncol Biol Phys. (2010) 76(3 Suppl.):S123–9. doi: 10.1016/j.ijrobp.2009.03.078

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Marks LB, Yorke ED, Jackson A, Ten Haken RK, Constine LS, Eisbruch A, et al. Use of normal tissue complication probability models in the clinic. Int J Radiat Oncol Biol Phys. (2010) 76(3 Suppl.):S10–9. doi: 10.1016/j.ijrobp.2009.07.1754

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Salembier C, Villeirs G, De Bari B, Hoskin P, Pieters BR, Van Vulpen M, et al. ESTRO ACROP consensus guideline on CT- and MRI-based target volume delineation for primary radiation therapy of localized prostate cancer. Radiother Oncol. (2018) 127:49–61. doi: 10.1016/j.radonc.2018.01.014

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Boehmer D, Maingon P, Poortmans P, Baron MH, Miralbell R, Remouchamps V, et al. Guidelines for primary radiotherapy of patients with prostate cancer. Radiother Oncol. (2006) 79:259–69. doi: 10.1016/j.radonc.2006.05.012

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Motegi K, Tachibana H, Motegi A, Hotta K, Baba H, Akimoto T. Usefulness of hybrid deformable image registration algorithms in prostate radiation therapy. J Appl Clin Med Phys. (2019) 20:229–36. doi: 10.1002/acm2.12515

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Feuvret L, Noel G, Mazeron JJ, Bey P. Conformity index: a review. Int J Radiat Oncol Biol Phys. (2006) 64:333–42. doi: 10.1016/j.ijrobp.2005.09.028

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Baltas D, Kolotas C, Geramani K, Mould RF, Ioannidis G, Kekchidi M, et al. A conformal index (COIN) to evaluate implant quality and dose specification in brachytherapy. Int J Radiat Oncol Biol Phys. (1998) 40:515–24. doi: 10.1016/S0360-3016(97)00732-3

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Clasie BM, Sharp GC, Seco J, Flanz JB, Kooy HM. Numerical solutions of the gamma-index in two and three dimensions. Phys Med Biol. (2012) 57:6981–97. doi: 10.1088/0031-9155/57/21/6981

PubMed Abstract | CrossRef Full Text | Google Scholar

23. van Zijtveld M, Dirkx M, Breuers M, Kuipers R, Heijmen B. Evaluation of the ‘dose of the day’ for IMRT prostate cancer patients derived from portal dose measurements and cone-beam CT. Radiother Oncol. (2010) 96:172–7. doi: 10.1016/j.radonc.2010.05.015

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Owen R, Kron T, Foroudi F, Milner A, Cox J, Duchesne G. Interfraction prostate rotation determined from in-room computerized tomography images. Med Dosim. (2011) 36:188–94. doi: 10.1016/j.meddos.2010.03.002

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Maeda Y, Sato Y, Minami H, Yasukawa Y, Yamamoto K, Tamamura H, et al. Positioning accuracy and daily dose assessment for prostate cancer treatment using in-room CT image guidance at a proton therapy facility. Med Phys. (2018) 45:1832–43. doi: 10.1002/mp.12858

PubMed Abstract | CrossRef Full Text | Google Scholar

26. Wang Y, Efstathiou JA, Sharp GC, Lu HM, Ciernik IF, Trofimov AV. Evaluation of the dosimetric impact of interfractional anatomical variations on prostate proton therapy using daily in-room CT images. Med Phys. (2011) 38:4623–33. doi: 10.1118/1.3604152

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Ariyaratne H, Chesham H, Pettingell J, Alonzi R. Image-guided radiotherapy for prostate cancer with cone beam CT: dosimetric effects of imaging frequency and PTV margin. Radiother Oncol. (2016) 121:103–8. doi: 10.1016/j.radonc.2016.07.018

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Li W, Vassil A, Godley A, Mossolly LM, Shang Q, Xia P. Using daily diagnostic quality images to validate planning margins for prostate interfractional variations. J Appl Clin Med Phys. (2016) 17:61–74. doi: 10.1120/jacmp.v17i3.5923

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Shelley LEA, Scaife JE, Romanchikova M, Harrison K, Forman JR, Bates AM, et al. Delivered dose can be a better predictor of rectal toxicity than planned dose in prostate radiotherapy. Radiother Oncol. (2017) 123:466–71. doi: 10.1016/j.radonc.2017.04.008

PubMed Abstract | CrossRef Full Text | Google Scholar

30. de Crevoisier R, Bayar MA, Pommier P, Muracciole X, Pene F, Dudouet P, et al. Daily versus weekly prostate cancer image-guided radiotherapy: phase 3 multicenter randomized trial. Int J Radiat Oncol Biol Phys. (2018) 102:1420–9. doi: 10.1016/j.ijrobp.2018.07.2006

CrossRef Full Text | Google Scholar

31. Tondel H, Lund JA, Lydersen S, Wanderas AD, Aksnessaether B, Jensen CA, et al. Radiotherapy for prostate cancer - Does daily image guidance with tighter margins improve patient reported outcomes compared to weekly orthogonal verified irradiation? Results from a randomized controlled trial. Radiother Oncol. (2018) 126:229–35. doi: 10.1016/j.radonc.2017.10.029

PubMed Abstract | CrossRef Full Text | Google Scholar

32. Tyagi N, Fontenla S, Zelefsky M, Chong-Ton M, Ostergren K, Shah N, et al. Clinical workflow for MR-only simulation and planning in prostate. Radiat Oncol. (2017) 12:119. doi: 10.1186/s13014-017-0854-4

PubMed Abstract | CrossRef Full Text | Google Scholar

33. de Muinck Keizer DM, Pathmanathan AU, Andreychenko A, Kerkmeijer LGW, van der Voort van Zyp JRN, Tree AC, et al. Fiducial marker based intra-fraction motion assessment on cine-MR for MR-Linac treatment of prostate cancer. Phys Med Biol. (2019) 64:07NT02. doi: 10.1088/1361-6560/ab09a6

PubMed Abstract | CrossRef Full Text | Google Scholar

34. Kurz C, Suss P, Arnsmeyer C, Haehnle J, Teichert K, Landry G, et al. Dose-guided patient positioning in proton radiotherapy using multicriteria-optimization. Z Med Phys. (2018) 29:216–28. doi: 10.1016/j.zemedi.2018.10.003

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Takam R, Bezak E, Yeoh EE, Marcu L. Assessment of normal tissue complications following prostate cancer irradiation: comparison of radiation treatment modalities using NTCP models. Med Phys. (2010) 37:5126–37. doi: 10.1118/1.3481514

PubMed Abstract | CrossRef Full Text | Google Scholar

36. Giantsoudi D, Baltas D, Karabis A, Mavroidis P, Zamboglou N, Tselis N, et al. A gEUD-based inverse planning technique for HDR prostate brachytherapy: feasibility study. Med Phys. (2013) 40:041704. doi: 10.1118/1.4793766

PubMed Abstract | CrossRef Full Text | Google Scholar

37. Zamboglou C, Sachpazidis I, Koubar K, Drendel V, Wiehle R, Kirste S, et al. Evaluation of intensity modulated radiation therapy dose painting for localized prostate cancer using (68)Ga-HBED-CC PSMA-PET/CT: a planning study based on histopathology reference. Radiother Oncol. (2017) 123:472–7. doi: 10.1016/j.radonc.2017.04.021

CrossRef Full Text | Google Scholar

38. Kallman P, Agren A, Brahme A. Tumour and normal tissue responses to fractionated non-uniform dose delivery. Int J Radiat Biol. (1992) 62:249–62. doi: 10.1080/09553009214552071

PubMed Abstract | CrossRef Full Text | Google Scholar

39. Miralbell R, Roberts SA, Zubizarreta E, Hendry JH. Dose-fractionation sensitivity of prostate cancer deduced from radiotherapy outcomes of 5,969 patients in seven international institutional datasets: alpha/beta = 1.4 (0.9-2.2) Gy. Int J Radiat Oncol Biol Phys. (2012) 82:e17–24. doi: 10.1016/j.ijrobp.2010.10.075

PubMed Abstract | CrossRef Full Text | Google Scholar

40. Agren A, Brahme A, Turesson I. Optimization of uncomplicated control for head and neck tumors. Int J Radiat Oncol Biol Phys. (1990) 19:1077–85. doi: 10.1016/0360-3016(90)90037-K

PubMed Abstract | CrossRef Full Text | Google Scholar

41. Zhou SM, Das S, Wang Z, Marks LB. Relationship between the generalized equivalent uniform dose formulation and the Poisson statistics-based tumor control probability model. Med Phys. (2004) 31:2606–9. doi: 10.1118/1.1783532

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: prostate cancer, image-guided radiotherapy, dosimetry, organs-at-risk, tumor control probability

Citation: Bostel T, Sachpazidis I, Splinter M, Bougatf N, Fechter T, Zamboglou C, Jäkel O, Huber PE, Baltas D, Debus J and Nicolay NH (2019) Dosimetric Impact of Interfractional Variations in Prostate Cancer Radiotherapy—Implications for Imaging Frequency and Treatment Adaptation. Front. Oncol. 9:940. doi: 10.3389/fonc.2019.00940

Received: 13 May 2019; Accepted: 06 September 2019;
Published: 27 September 2019.

Edited by:

Sean P. Collins, School of Medicine, Georgetown University, United States

Reviewed by:

Giovanni Lasio, University of Maryland, United States
Ima Paydar, Hospital of the University of Pennsylvania, United States

Copyright © 2019 Bostel, Sachpazidis, Splinter, Bougatf, Fechter, Zamboglou, Jäkel, Huber, Baltas, Debus and Nicolay. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Nils H. Nicolay, nils.nicolay@uniklinik-freiburg.de

These authors have contributed equally to this work

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.