Pang et al. (2017) have raised reproducibility concerns about our ISCA-based magnetogenetic stimulation approach (Long et al., 2015). However, we strongly suspect that poor plasmid design and expression efficiency may explain their failure to reproduce our earlier findings, which demonstrated ISCA-based magnetic stimulation in seven systematic experiments carried out at the cellular, electrophysiological, circuit, and behavioral levels. In the following commentary, we highlight how flaws in the experimental design in their paper, and misinterpretations of our findings, introduce serious issues for the interpretation of their results.
The key to efficient magnetogenetic stimulation is the efficient delivery and expression of Isca1, previously renamed as MAR (Long et al., 2015). Pang and colleagues were not fully aware of how we designed our codon-optimized Isca1 expression constructs, and thus their claim to have been using DNA constructs that are “almost identical” to ours is inaccurate. We clearly stated that we used a CAG promoter, which is much stronger than their EF-1α promoter. In the interests of promoting future investigation into the matter, we will openly share our codon-optimized cDNA constructs with the scientific community upon request. Although we are unaware of the source and DNA sequence of the EF-1α promoter used by Pang and colleagues, Zheng and Baum emphasized that different sources and sequences of EF-1α promoter jeopardize target specificity and gene expression (Zheng and Baum, 2014), which is in agreement with our initial pretesting on promoter-dependent effectiveness of Isca1 for magnetogenetics. One likely explanation for such an apparent discrepancy is the large difference in expression level of Isca1.
Moreover, they performed many of their experiments after only 24 h of plasmid expression, rather than the 48 h post-transfection time window that we used. Their transfection efficiency (~30%) in HEK-293 cells was markedly lower than ours (~94%), and their transfection efficiency in neurons was poor (~3%) when compared to our population-wide infection (100%, Figures 1A,B) using our rAAV system (Zhang et al., 2007, 2013). In light of their limited Isca1 expression under a weaker promoter and with a shorter expression time, we believe that their expression levels fell substantially short of ours, which is a very likely explanation for why they were unable to reproduce our earlier magnetogenetic stimulation results.
Figure 1
They inferred that our 350% increase in calcium influx was due to magnetic stimulation for “as long as 7 min.” In fact, our magnetic stimulus was applied for only 10–60 s, and it was the subsequent calcium activity that was measured for over 7 min. Furthermore, they expressed disbelief that we could evoke calcium responses with 1.0 mT. Actually, we varied the magnetic strength and found the threshold for detecting calcium response with GCaMP6s to be as low as 0.3 mT (Figures 1C,D), indicating that efficient expression of ISCA1 is the critical prerequisite in a functional magnetogenetic stimulation paradigm.
Furthermore, they raised concerns that our magnetic device “could raise the temperature of the cultured cells, leading to calcium changes.” However, this possibility could be ruled out for three reasons: First, all stimulation was performed at room temperature using static magnetic fields produced by electromagnetic coils or magnetic bars, which generate no power (and therefore introduce negligible heat); Second, no calcium increase was observed in ISCA1-negative cells by using the same setup; and Third, in TRPV-based magnetothermal strategies (Huang et al., 2010; Stanley et al., 2012) involving temperatures up to 43°C, the TRPV-negative cells exhibited no detectable calcium increases, suggesting that high temperature alone is insufficient to evoke calcium influx (Chen et al., 2015).
Pang and colleagues instead suggest that “the only difference was that we used an inverted microscope with ample air circulation, while the previous study used an upright microscope.” In fact, upright microscopes are very commonly used for calcium imaging in vitro and in vivo. Furthermore, action potentials were observed in our patch clamp experiments using an inverted microscope, suggesting that the type of microscope is irrelevant to magnetic activation.
They raised the possibility that “unhealthy cell state” may have contributed to “merely random firing.” This is incorrect for multiple reasons: (i) synchronous calcium responses were elicited; (ii) multiple rounds of rapidly reversible neuronal activation were time-locked to magnetic field presentation; (iii) spontaneous calcium transients in ISCA1-negative neurons were very infrequent when compared with evoked responses in ISCA1-positive cells; (iv) on-/off- and direction-dependent responses were detected by calcium imaging and patch-clamp recording; and (v) no significant differences were observed in intrinsic electrical properties between ISCA1-positive and ISCA1-negative neurons. This evidence strongly argues against their speculation of an “unhealthy cell state.”
They also suggested that “a sustained elevation of intracellular calcium could be an indication of an unhealthy state” referring to calcium responses in our HEK-293 cells that “continued to rise but never came down.” Surprisingly, they appeared unaware that similar patterns had been reported in HEK-293 cells in other prominent studies (Chen et al., 2015; Wheeler et al., 2016). Notably, transient calcium influx in neurons and saturating responses in HEK-293 cells may reflect differences in their cellular and electrophysiological properties or even their expression efficiency for ISCA1.
Furthermore, they emphasized without scientific rationale that the average calcium response onset latency of 7.8 s that we reported was “very long” and “very unusual” in that all neuronal stimuli “fall in the millisecond range.” In fact, onset latencies of existing magnetic actuators are all in the range of seconds rather than milliseconds. For instance, Chen et al. (2015) reported onset latencies of ~5 s and ~15 s for neurons and HEK-293-FT cells, respectively (Figures 1E,F). Considering the differences in physical properties between light and magnetic fields and in the biophysical features of light-sensitive vs. magnetism-sensitive proteins, it is not at all surprising that the temporal kinetics of magnetogenetics would be different from that of optogenetics.
While Pang and colleagues made laudable efforts to perform “positive control” applications of ATP or KCl to verify the calcium responses of their cells, unfortunately, the most important positive control is missing: comparisons, under their conditions of similarly low expression efficiency, of Isca1 with the other four published magnetogenetic actuators, which include Ferritin-TRPV1, Ferritin-TRPV4, Nanoparticle-TRPV1, and EPG (Chen et al., 2015; Stanley et al., 2016; Munshi et al., 2017; Krishnan et al., 2018). Without this side by side comparison, the critical positive control for magnetic field generation that is sufficient to activate these levels of protein expression is lacking.
There were various other issues that may have impeded their ability to replicate our experiments properly. For example, they used the HEPES buffer instead of the commonly used calcium imaging buffer, which may have altered cellular excitability.
Since ISCA1-based magnetogenetics is still in its infancy, we hope that our discovery will stimulate further advances in this line of research (Knöpfel and Akemann, 2010). Given the arguments presented here, we believe that our key finding, that ISCA1 alone is sufficient to enable magnetic control of cellular activity, remains valid, and we are optimistic that future experimentation will confirm and build on the foundations of our work.
Statements
Author contributions
All authors listed have made a substantial, direct and intellectual contribution to the work, and approved it for publication.
Funding
The authors are supported by the startup funds from Xinqiao Hospital and Army Medical University, China as well as from Shenzhen University, China.
Acknowledgments
We are grateful to all members of the Zhang Lab for their support.
Conflict of interest
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
References
1
ChenR.RomeroG.ChristiansenM. G.MohrA.AnikeevaP. (2015). Wireless magnetothermal deep brain stimulation. Science347, 1477–1480. 10.1126/science.1261821
2
HuangH.DelikanliS.ZengH.FerkeyD. M.PralleA. (2010). Remote control of ion channels and neurons through magnetic-field heating of nanoparticles. Nat. Nanotechnol.5, 602–606. 10.1038/nnano.2010.125
3
KnöpfelT.AkemannW. (2010). Nanobiotechnology: remote control of cells. Nat. Nanotechnol.5, 560–561. 10.1038/nnano.2010.163
4
KrishnanV.ParkS. A.ShinS. S.AlonL.TresslerC. M.StokesW.et al. (2018). Wireless control of cellular function by activation of a novel protein responsive to electromagnetic fields. Sci. Rep.8:8764. 10.1038/s41598-018-27087-9
5
LongX.YeJ.ZhaoD.ZhangS. J. (2015). Magnetogenetics: remote non-invasive magnetic activation of neuronal activity with a magnetoreceptor. Sci. Bull.60, 2107–2119. 10.1007/s11434-015-0902-0
6
MunshiR.QadriS. M.ZhangQ.Castellanos RubioI.Del PinoP.PralleA. (2017). Magneto-thermal genetic deep brain stimulation of motor behaviors in awake, freely moving mice. Elife6:27069. 10.7554/eLife.27069
7
PangK.YouH.ChenY.ChuP.HuM.ShenJ.et al. (2017). MagR alone is insufficient to confer cellular calcium responses to magnetic stimulation. Front. Neural Circuits11:11. 10.3389/fncir.2017.00011
8
StanleyS. A.GagnerJ. E.DamanpourS.YoshidaM.DordickJ. S.FriedmanJ. M. (2012). Radio-wave heating of iron oxide nanoparticles can regulate plasma glucose in mice. Science336, 604–608. 10.1126/science.1216753
9
StanleyS. A.KellyL.LatchaK. N.SchmidtS. F.YuX.NectowA. R.et al. (2016). Bidirectional electromagnetic control of the hypothalamus regulates feeding and metabolism. Nature531, 647–650. 10.1038/nature17183
10
WheelerM. A.SmithC. J.OttoliniM.BarkerB. S.PurohitA. M.GrippoR. M.et al. (2016). Genetically targeted magnetic control of the nervous system. Nat. Neurosci.19, 756–761. 10.1038/nn.4265
11
ZhangS. J.SteijaertM. N.LauD.SchutzG.Delucinge-VivierC.DescombesP.et al. (2007). Decoding NMDA receptor signaling: identification of genomic programs specifying neuronal survival and death. Neuron53, 549–562. 10.1016/j.neuron.2007.01.025
12
ZhangS. J.YeJ.MiaoC.TsaoA.CerniauskasI.LedergerberD.et al. (2013). Optogenetic dissection of entorhinal-hippocampal functional connectivity. Science340:1232627. 10.1126/science.1232627
13
ZhengC.BaumB. J. (2014). All human EF1alpha promoters are not equal: markedly affect gene expression in constructs from different sources. Int. J. Med. Sci.11, 404–408. 10.7150/ijms.8033
Summary
Keywords
magnetogenetics, ISCA1, optogenetics, GCaMP, neuromodulation, non-invasive brain stimulation
Citation
Long X and Zhang S-J (2018) Commentary: MagR Alone Is Insufficient to Confer Cellular Calcium Responses to Magnetic Stimulation. Front. Neural Circuits 12:97. doi: 10.3389/fncir.2018.00097
Received
23 October 2017
Accepted
11 October 2018
Published
12 November 2018
Volume
12 - 2018
Edited by
Edward S. Ruthazer, McGill University, Canada
Reviewed by
Philippe Séguéla, McGill University, Canada; Michael Levin, Tufts University, United States
Updates
Copyright
© 2018 Long and Zhang.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Sheng-Jia Zhang sheng-jia.zhang@tmmu.edu.cn; sheng-jia.zhang@outlook.com
Disclaimer
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.