Abstract
Background: In the past decade, continuous glucose monitoring (CGM) has been proven to have similar accuracy to self-monitoring of blood glucose (SMBG) and yet provides better therapy optimization and detects trends in glucose values due to higher frequency of testing. Even though the feasibility and utility of CGM has been proven successfully in Type 1 and 2 diabetes, there is a lack of knowledge of its application and effectiveness in pregnancy, especially in gestational diabetes mellitus (GDM). In this review, we aimed to summarize and evaluate the updated scientific evidence on the application of CGM in pregnancies complicated with GDM.
Methods: A search using keywords related to CGM and GDM on PubMed was conducted and articles were filtered based on full text, year of publication (Jan 1998–Dec 2018), human subject studies, and written in English. Reviews and duplicate articles were removed. A final total of 29 articles were included in this review.
Results: In terms of maternal and fetal outcomes, inconsistent evidence was reported. Among GDM patients using CGM and SMBG, two randomized controlled trials (RCTs) found no significant differences in macrosomia, birth weight (BW), and gestational age (GA) at delivery between these two groups, while one prospective cohort found a lower incidence of cesarean section and macrosomia in CGM use subjects. Furthermore, CGM use was consistently found to have increased detection in dysglycemia and glycemic variability compared to SMBG. In terms of clinical utility, CGM use led to more treatment adjustments and lower gestational weight gain (GWG). Lastly, CGM use showed higher postprandial glucose levels in GDM-complicated pregnancies than in normal pregnancies.
Conclusion: Current updated evidence suggests that CGM is superior to SMBG among GDM pregnancies in terms of detecting hypoglycemic and hyperglycemic episodes, which might result in an improvement of maternal and fetal outcomes. In addition, CGM detects a wider glycemic variability in GDM mothers than non-GDM controls. Further research with larger sample sizes and complete pregnancy coverage is needed to explore the clinical utility such as screening and predictive values of CGM for GDM.
Hyperglycemia during pregnancy without a history of diabetes is known as gestational diabetes mellitus (GDM), with worldwide prevalence of 5–10% before 2010 (1–3). However, the prevalence has greatly increased after the new evidence-based guidelines from the International Association of Diabetes and Pregnancy Groups (IADPSG) were published and officially adopted in 2013 (1). The criteria was developed from the Hyperglycemia and Adverse Pregnancy Outcomes (HAPO) study (2) which showed that glucose levels correlate with maternal and fetal outcomes in a linear trend (3). Since the new criteria lowered the fasting glucose threshold significantly compared to other international guidelines [e.g., 5.1 mmol/L (92 mg/dL) vs. World Health Organization (WHO) 1999 7.0 mmol/L (126 mg/dL) (4) vs. National Institute for Clinical Evidence (NICE) 6.1 mmol/L (110 mg/dL)] (5), the GDM prevalence in 2015 increased by 2–3 folds to 25.1% in Singapore, 18% in Brazil, and 45.3% in United Arab Emirates (4).
Once a pregnant mother is diagnosed with GDM, she will be treated with either diet, medication (i.e., insulin), or both. In addition, she will be required to monitor her own glucose level closely using self-monitoring of blood glucose (SMBG) that involves finger pricking up to seven times daily. However, SMBG provides an incomplete picture of the daily glucose profile due to long intervals between finger pricking, and inaccurate self-reported measures which heavily rely on patients' compliance (6). Furthermore, reported barriers of using SMBG include stigma of testing in public places, pain, inconvenience, (7) and patient anxiety (8). Thus, there is a growing need for newer devices that could provide more frequent glucose measurements, improve patient compliance, and increase accuracy in reported data.
In the past decade, continuous glucose monitoring (CGM)—a new device that uses a subcutaneous sensor to measure interstitial fluid glucose levels—has been developed and advanced greatly in terms of clinical application (9). It offers a continuous measure of glucose profile and has been proven to show comparable accuracy compared with SMBG (6). Furthermore, CGM is more promising in clinical practice than SMBG in terms of a higher frequency of testing, trends in glucose values, alarms for dysglycemia (especially hypoglycemia) detection, therapy optimization, and identification of glucose fluctuations (10). With the wide adoption in clinical practice, CGM use has been shown to improve HbA1c and reduce glucose variability in patients with Type 1 Diabetes (T1D) (10) and is better for treatment monitoring than SMBG use in patients with Type 2 Diabetes (T2D) (11). Although CGM has been used successfully in T1D and T2D patients, the effectiveness of CGM in improving pregnancy outcomes complicated by GDM is still understudied.
In this review, we aimed to summarize and evaluate the use of CGM technology in pregnancies complicated by GDM, especially pertaining to feasibility, acceptability and efficacy (i.e., improvement in clinical outcomes and treatment effect). We hypothesized that there is strong evidence on the potential values of CGM in detecting more complete gestational glucose profiling, more episodes of dysglycemia, and in improving pregnancy outcomes and glycemic control among pregnant women with GDM.
Methods
We conducted a broad search (conducted by QY and verified by L-JL) on PubMed, Scopus, and Web of Science using possible combination of terms from two themes featuring CGM and GDM, as shown in Figure 1. We first filtered full-text articles published between Jan 1st, 1998 and Dec 31st, 2018 that were mainly human studies and written in English. With these inclusion criteria, 560 articles remained. Second, we excluded duplicate articles (n = 191). Third, we removed articles without relevant titles (n = 132). Fourth, we excluded peer-reviews (n = 55) and lastly, we excluded articles without relevant abstracts (n = 105). We included a total of 29 articles in this review.
Figure 1
Results
Table 1 shows the characteristics of the 29 studies included, of which 3 were randomized controlled trials (RCTs), one was a randomized crossover trial, and the remaining 25 were prospective observational cohorts with a small to medium number of subjects (n = 8–340). The majority of studies (n = 20) used Minimed (Medtronic, Dublin, Ireland) with 72 h monitoring. Other studies applied devices including GlucoDay S (GDS) (A.Menarini Diagnostics Ltd, Florence, Italy) (n = 2), Guardian (Medtronic, Dublin, Ireland) (n = 1), Seven and Seven Plus (Dexcom, San Diego, USA) (n = 1), iPro2 (Medtronic, Dublin, Ireland) (n = 4) and Freestyle Libre Flash Glucose Monitoring (FGM) (Abott, Illinois, USA) (n = 1).
Table 1
| References, Country | Population (GA in weeks) | Device and usage | Study design | Exposure | Outcomes | Limitations | |
|---|---|---|---|---|---|---|---|
| 1 | Yogev et al. (12) UK | N = 2 (24–32 weeks) 2GDM | 72-h MiniMed, Medtronic Twice: 1x baseline, 1x post-treatment (2–4 weeks later) | Prospective observational study | CGM vs. SBGM use | Differences in glucose levels and insulin regimen | 1. Under-controlled study 2. Small number of patients, 3. No clinical difference in perinatal outcome between CGM and SBGM due to lack of power |
| 2 | Chen et al. (13) Isreal and USA | N = 57 (32–36 weeks) Isreal: 47 GDM 23 diet only 24 diet and insulin (24–32) USA: 10 GDM | 72-h MiniMed Medtronic Once | Prospective observational study | CGM vs. SBGM use | Daily glycemic profile | 1. Non-standardized data analyses between two study sites |
| 3 | Ben-Haroush et al. (14) USA | N = 45 (25–32 wks avg) 45 GDM 26 by diet 19 by insulin | 72 h MiniMed Medtronic Once | Prospective observational study | CGM vs. SMBG use | Peak postprandial glucose levels | 1. Small sample size 2. No data on association between postprandial glucose levels and pregnancy outcomes |
| 4 | Buhling et al. (15) Germany | N = 64 (31–34 weeks) 8 non-pregnant NGT 56 pregnant women: 17 diet treated GDM (2 or 3 abnormal value on 75 g OGTT) 15 with IGT (1 abnormal value on 75 g OGTT) 24 NDP women (31–34) | 72-h MiniMed Medtronic Once | Prospective observational study | CGM vs. SBGM use | Glucose profile | 1. Small number of patients 2. No assessment of the clinical significance of hyperglycemic intervals |
| 5 | Yogev et al. (16) USA | N = 117 (32–33 weeks) 82 GDM: 27 diet only 30 on insulin 25 treated with glyburide 35 NDP women | 72-h MiniMed Medtronic Once | Prospective observational study | CGM vs. SBGM | Hypoglycemic episodes | 1. Did not study perinatal or maternal outcomes 2. No significant hypoglycemic events were identified in any patients |
| 6 | Buhling et al. (17) Germany | N = 49 (24–37 weeks) 36 NDP 13 GDM | 72-h MiniMed Medtronic Once | Prospective observational study | CGM vs. SBGM use and diet | Postprandial glucose time to peak Postprandial glucose values | 1. Unable to detect clinical outcome differences due to lack of power from small number of study subjects |
| 7 | Cypryk et al. (12) Poland | N = 19 (>28 wks) 12 GDM: 7 diet only 5 diet and insulin 7 NDP | 72-h MiniMed Medtronic Once | Prospective observational study | CGM vs. SBGM | Glycemic control | 1. Small number of study subjects 2. No fetal/obstetric outcomes measured |
| 8 | McLachlan et al. (18) Australia | N = 36 (10–34 weeks) 36 GDM | 72-h MiniMed Medtronic Once | Prospective observational study | CGM vs. SBGM use | Clinical usefulness Patient assessment of usefulness Accuracy of CGMS | 1. No blinded third party for assessing CGMS results 2. No statistical analysis of data 3. Not all target women agreed to participate which could lead to overestimation of usefulness of CGMS |
| 9 | Kestila et al. (19) Finland | N = 73 (>28 weeks) All with GDM 36 with GDM using CGM 37 with GDM using SMBG | Average 47.4-hr MiniMed, Medtronic Once | Prospective observational study | CGM vs. SBGM use | Determination of medical intervention | 1. Study was not powered to detect differences in obstetrical outcome such as macrosomia. 2. Some mothers were not treated with antihyperglycemic medication even though indicated based on CGMS values |
| 10 | Seshiah et al. (20) India | N = 24 (22–30 weeks) 12 with GDM 12 NDP | 72 h MiniMed Medtronic Once | Prospective observational study | CGM use | Postprandial time to peak | 1. Only 3 SMBG measurements per day 2. Small sample size |
| 11 | Dalfra et al. (3) Italy | N = 48 (GA not specified) 31 with GDM (Carpenter and Coustan criteria1), 17 NDP | 48-h GlucoDay S (GDS) Menarini Diagnostics Twice: 1 in 2nd trimester 1 in 3rd trimester | Prospective observational study | CGM vs. SBGM use | Relationship between glycemic profiles and fetal growth | 1. Small number of patients 2. BMI in women with diabetes was significantly higher before pregnancy compared to controls |
| 12 | Mazze et al. (21) USA | N = 82 (>27 weeks) 51 NDP 25 GDM 6 Pre-GD 21 non-pregnant NGT | 72-h Guardian, Medtronic Once during 3rd trimester | Prospective, observational study | CGM vs. SBGM use in glyburide vs. insulin vs. diet | Diurnal glucose patterns of women | 1. Only 3 days of testing for each sensor 2. Women were not randomly selected |
| 13 | Colatrella et al. (22) Italy | N = 33 (postpartum) 18 with GDM 15 NDP | 72-h MiniMed, Medtronic Once | Prospective observational study | Suckling effect, CGM vs. SBGM use | Glucose profiles | 1. Significant difference in BMI between groups 2. It cannot be ruled out that differences in glycemic profiles between groups could be due to diet |
| 14 | Dalfra et al. (23) Italy | N = 30 20 with GDM 10 NDP | 48 h GlucoDay Once each trimester | Prospective observational study | CGM use | Glycemic variabilityHbA1c | 1. Small sample size 2. Short monitoring period 3. Multiple recruitment centers with subsequent pooling of study population |
| 15 | Su et al. (24) China | N = 70 (25 weeks) 30 GDM pregnant women 20 NDP 20 non-pregnant NGT | 72-h MiniMed, Medtronic Once | Prospective observational study | CGM vs. SBGM use | Glycemic variability and its association with B cell function | 1. Study was not powered to detect associations between glycemic variability and pregnancy outcomes |
| 16 | Hernandez et al. (25) USA | N = 16 (31 weeks avg) All with GDM | 72 h MiniMed Medtronic Twice | Randomized crossover study | Higher vs. lower carbohydrate diets | Postprandial glucose levels and insulin levels | 1. Small study sample 2. Short duration 3. Highly controlled diet exposure |
| 17 | Yu et al. (26) China | N = 340 (26 weeks) 190 GDM with SMBG 150 GDM with SMBG and CGM | 72-h MiniMed, Medtronic In SMBG group, twice (1st and 5th week of study) In SMBG and CGM group, every 2-4 weeks from study start to delivery | Prospective observational study | CGM vs. SBGM use, insulin vs. diet | Maternal complications: PE, miscarriage, IUFD, cesarean delivery. Neonatal outcomes: GA, preterm birth, BW, BW percentile, neonatal complications | 1. Sample size inadequate for substantial positive cases of neonatal complications 2. In routine care group CGM data was analyzed in relation to pregnancy outcomes even though they were obtained only in 1st and 5th week of study |
| 18 | Kusunoki et al. (27) Japan | N = 22 (13 weeks) All with GDM | 48-h MiniMed, Medtronic Once during the first 3 weeks of GDM diagnosis | Prospective observational study | CGM vs. SMBG use | Postprandial hyperglycemia HbA1c | 1. No controls of healthy pregnant women |
| 19 | Sung et al. (24) US | N = 53 (24–28 weeks) NDP 2-step ACOG 9 failed 50 g GCT and screened with 75 g OGTT Diagnosed with GDM | 6–7 days Seven and Seven Plus, Dexcom Avg use 4.8 days | Prospective observational study | CGM vs. SMBG use, food diary effect | Primary outcome: BW percentile Secondary outcomes: unplanned operative delivery and macrosomia | 1. The GDM diagnostic criteria was changed midway through study 2. Data was collected only during 24–28 weeks gestation 3. Sample size was underpowered to detect differences in secondary outcomes |
| 20 | Wang et al. (28) China | N = 96 48 NDP with previous GDM 48 NDP w/out previous GDM | 72 h MiniMed Medtronic Once | Prospective observational study | CGM use | Glycemic variability | 1. Sample size was underpowered to detect differences in subgroups 2. Factors such as physical activating and emotional stress could not be controlled and could affect glycemic variability |
| 21 | Alfadhli et al. (29) Saudi Arabia | N = 130 (26 weeks avg) 62 with GDM and SMBG 68 with GDM and CGM | 3–7 days Minimed Medtronic Once | Prospective open label randomized controlled study | CGM vs. SMBG use | Maternal glycemic control Pregnancy outcomes Glucose variability | 1. Single use of CGM 2. Small sample size |
| 22 | Carreiro et al. (30) Brazil | N = 50 (27–36 weeks) 36 with GDM 14 non-pregnant BMI matched NGT | 72-h Minimed, Medtronic Once | Prospective observational study | CGM vs. SMBG use | Glucose profiles Effects of dietary counseling on glucose profiles | 1. Pooled glucose profiles is one summary point rather than all measurements. 2. No analysis on perinatal outcomes 3. No evaluation of the same patients before and after dietary counseling with CGM |
| 23 | Wei et al. (31) China | N = 120 (24–36 weeks) 58 with GDM in CGM 62 with GDM in SMBG | 48–72-h Gold MiniMed, Medtronic Once | Prospective, observational, open-label randomized controlled trial | CGM vs. SMBG use, diet vs. insulin | Maternal: GWG, cesarean section Neonatal: BW Apgar score at 5 min HbA1c levels Glucose variability | 1. Small sample size with no significant differences in outcomes 2. Education management was not blinded (Hawthorne effect) |
| 24 | Naik et al. (32) India | N = 30 (24–36 weeks) 20 with GDM 10 NDP | 72-h MiniMed Medtronic Once | Prospective observational study | CGM vs. SMBG, Medical nutrition intervention vs. insulin | Masked hypoglycemia (interstitial glucose levels <2.7 mmol/L [48.6 mg/dL] for >30 min without symptoms detected by CGM) | 1. More women in CGM group underwent cesarean section but most of them were elective 2. Small sample size |
| 25 | Panyakat et al. (33) Thailand | N = 55 (28–32 weeks) All with GDM | 72 h iPro2 Medtronic Once | Prospective observational study | CGM use | Glycemic variability Pregnancy outcomes | 1. Low incidence of perinatal outcomes 2. Study conducted in third trimester only |
| 26 | Paramasivam et al. (34) Malaysia | N = 50 (28, 32, 36 weeks) All insulin-treated GDM: 25 with CGM 25 with SMBG | 7 days iPro2 Medtronic Three times | Prospective randomized open label controlled trial | CGM vs. SMBG use | HbA1c | 1. Small sample size 2. Unblinded participants and practitioners |
| 27 | Pustozerov et al. (35) Russia | N = 62 (31 weeks avg) 49 with GDM 13 NDP | 7 days iPro2 Medtronic | Prospective observational trial | Mobile app, CGM use vs. SMBG | Postprandial peak glucose levels Postprandial time to peak FBG | 1. Self-reported food intake 2. Small sample size 3. Accuracy of prediction models has not been proven |
| 28 | Scott et al. (36) UK and Austria | N = 39 (26.6 weeks avg) 39 with GDM | Up to 14 days FreeStyle Libre FGM system (Abbott Diabetes Care) Once | Prospective observational trial | CGM vs. SMBG | Accuracy User acceptability Safety evaluation | 1. Sample size not powered to detect accuracy between subgroups 2. Short term study |
| 29 | Voormolen et al. (37) Holland | N = 109 (<30 weeks) 109 with GDM Among them, 147 using CGM 153 using standard treatment | 5–7 day iPRO2 retrospective CGM, Medtronic Once in every 6 weeks | Open label, multicenter, randomized controlled trial | CGMS vs. SMBG use | Primary outcome: macrosomia, Secondary outcomes: BW, neonatal and maternal morbidity HbA1cGlucose variability | 1. Enrollment took place over more than 4 years 2. High number of patients refused continued use of CGM 3. Cannot compare CGM related outcomes b/c not blinded |
Characteristics of included studies.
Carpenter and Coustan criteria: 3 h OGTT with fasting ≥ 95 mg/dL [5.4 mmol/L], 1 h ≥ 180 mg/dL [10 mmol/L], 2 h ≥ 155 mg/dL [8.6 mmol/L], or 3 h ≥ 140 mg/dL [7.8 mmol/L].
GA, Gestational age; CGM, Continuous glucose monitoring; SMBG, Self-monitoring of blood glucose; GDM, Gestational diabetes; T1D, Type 1 diabetes; IGT, Impaired glucose tolerance; NDP, Non-diabetic pregnancy; T2D, Type 2 diabetes; NGT, Normal glucose tolerance; OGTT, Oral glucose tolerance test; BMI, Body mass index; PE, Preeclampsia; GA, Gestational age; BW, Birth weight; GWG, Gestational weight gain; FBG, Fasting blood glucose.
We summarize the major findings categorized below:
CGM vs. SMBG in Terms of Feasibility and Acceptability (Table 2)
Two studies which focused on user acceptability found that CGM use was generally well-tolerated by patients. McLachlan et al. demonstrated that CGM was able to provide an additional 62% of information that is missing in patients' self-recorded glucose diaries (18). Most patients felt that CGM is easy to use (44 out of 48, 92%), beneficial for self-glycemic control (43 out of 48, 90%), and that its use outweighed its inconvenience (37 out of 48, 77%) (18). Likewise, Scott et al. demonstrated that CGM had acceptable accuracy (88.1% within Zone A of Consensus Error Grid) with only 11.8% mean difference with SMBG (36).
Table 2
| References, Country | Other outcomes | |
|---|---|---|
| 1 | McLachlan et al. (18) Australia | 1. Positive user feedback 2. CGM vs. SMBG: ↑ Information gathering |
| 2 | Colatrella et al. (22) Italy | Suckling did not affect blood glucose profiles significantly. |
| 3 | Wang et al. (28) China | Previous GDM vs. w/out previous GDM: ↓ Integrated B cell function index 90% acceptability |
| 4 | Scott et al. (36) UK and Austria | CGM vs. SMBG: Acceptable accuracy with 11.8% absolute relative difference High user acceptabilityNo AE |
Other outcomes of articles.
CGM, Continuous glucose monitoring; GDM, Gestational diabetes; SMBG, Self-monitoring of blood glucose.
CGM vs. SMBG and Risk of Adverse Pregnancy Outcomes (Table 3)
Two RCTs and 1 prospective cohort showed no differences in any maternal and fetal outcomes between CGM use and SMBG use among GDM pregnancies, while 3 other studies, including 1 RCT and 2 prospective cohorts, reported otherwise.
Table 3
| References, Country | Pregnancy outcomes | ||
|---|---|---|---|
| Maternal | Fetal | ||
| 1 | Kestila et al. (19) Finland | CGM vs. SMBG: HDP: Nil C-section: Nil GA at delivery: Nil | CGM vs. SMBG: BW: Nil Neonatal hypoglycemia: Nil |
| 2 | Yu et al. (26) China | CGM vs. SMBG: ↓ PE ↓ PTD ↓ C-section | CGM vs. SMBG: ↓ BW ↓ Macrosomia ↓ LGA ↓ Neonatal complications (hypoglycemia, hyperbilirubinemia, RDS) |
| 3 | Sung et al. (38) USA | Hyperglycemia and BW %tile: Positive correlation | |
| 4 | Alfadhli et al. (29) Saudi Arabia | CGM vs. SMBG: C-section:Nil GA: Nil | CGM vs. SMBG: BW: Nil Macrosomia: Nil Neonatal hypoglycemia: Nil |
| 5 | Wei et al. (31) China | CGM vs. SMBG: C-section: Nil | CGM vs. SMBG: BW: Nil Macrosomia: Nil LGA: Nil SGA: Nil Neonatal hypoglycemia: Nil APGAR 5 min: Nil |
| 6 | Voormolen et al. (37) Holland | CGM vs. SMBG: HDP: Nil HELLP: Nil ↓ incidence of PE | CGM vs. SMBG: BW: Nil Macrosomia: Nil LGA: Nil SGA: Nil |
Major findings of articles with focus on pregnancy outcomes.
GA, Gestational age; HDP, Hypertensive disorders of pregnancy; c-section, Cesarean section; BW, Birth weight; PCOS, Polycystic ovarian syndrome; LGA, Large for gestational age; SGA, Small for gestational age; PE, Pre-eclampsia; PTD, Preterm delivery.
Maternal Outcomes
Wei et al. randomly assigned 120 pregnant women with GDM to either CGM (n = 58) or SMBG (n = 62) (31). CGM monitoring was done once for 48–72 h via MiniMed device (Medtronic, Dublin, Ireland) while traditional treatment involved SMBG (4 times daily) and HbA1c levels (every 4 weeks) (31). In this RCT, Wei et al. found no significant differences in cesarean section rates or HbA1c levels between CGM and SMBG users (31). Alfadhli et al. recruited 130 patients with GDM (62 SMBG, 68 CGM) and found no significant differences in cesarean section rates between the groups (29).
In addition, one prospective observational study also found no significant differences in maternal outcomes between CGM and SMBG groups. Kestila et al. enrolled 73 women with GDM and assigned 36 to CGM and 37 to SMBG (19). No differences were found in terms of frequency of pre-eclampsia, pregnancy-induced hypertension, maternal lacerations, and cesarean section rate between the 2 groups (19).
On the contrary, 2 studies found significant differences. Voormolen et al. randomized 109 women with GDM to CGM vs. standard treatment (SMBG 4–8 times daily and HbA1c levels every 4 weeks) (37). Compared with SMBG users, CGM users had a significantly lower incidence of pre-eclampsia [Relative Risk (RR) 0.3; 95%Cl: 0.12–0.8] (37). Yu et al. recruited 340 women with GDM and assigned 190 to routine care (SMBG 7 times daily) and the other 150–72 h CGM (26). Compared with SMBG, CGM users tended to have lower incidence of pre-eclampsia [5 out of 150 (3.3%) vs. 19 out of 190 (10%), P = 0.019], primary cesarean section [51 out of 150 (34.0%) vs. 88 out of 190 (46.3%), P = 0.028], and premature delivery [7 out of 150 (4.7%) vs. 22 out of 190 (11.6%), P = 0.024] (26).
Fetal Outcomes
The same studies also compared fetal outcomes between CGM and SMBG groups and all three RCTs found no significant differences (19, 29, 31, 37). Only one study by Yu et al. reported better fetal outcomes in the CGM group compared to SMBG group, in terms of BW (3,138 vs. 3,345 g, P < 0.001), numbers of macrosomia [6 out of 150 (4%) vs. 20 out of 190 (10.5%), P = 0.025], LGA [20 out of 150 (13.3%) vs. 48 out of 190 (25.3%), P = 0.01], neonatal hypoglycemia [8 out of 150 (5.3%) vs. 26 out of 190 (13.7%), P = 0.011], neonatal hyperbilirubinemia [4 out of 150 (2.7%) vs. 18 out of 190 (9.5%), P = 0.012], and neonatal respiratory distress syndrome (RDS) [2 out of 150 (1.3%) vs. 11 out of 190 (5.8%), P = 0.034] (26).
CGM vs. SMBG and Detection of Dysglycemia (Table 4)
Two prospective observational studies that compared CGM vs. SMBG to detect dysglycemia concluded that CGM detected more hypoglycemia and hyperglycemia incidents. Chen et al. conducted a study in Israel (n = 47) and USA (n = 10) on glucose profiling between CGM and SMBG in women with GDM (13), and found that CGM detected hyperglycemic and hypoglycemic events better than SMBG (13). The other study by McLachlan et al. studied the clinical usefulness of CGM in 36 patients with GDM and had similar conclusions (18). They found that CGM detected postprandial hyperglycemia that was underestimated by SMBG (18).
Table 4
| References, Country | Dysglycemia detection CGM vs. SMBG | Glycemic profiling | |
|---|---|---|---|
| 1 | Chen et al. (13) Isreal and USA | ↑ Hypoglycemia ↑ Hyperglycemia | Hyperglycemia and Hba1c: Nil |
| 2 | Ben-Haroush et al. (14)USA | T1D vs. GDM: ↑ Variation in postprandial glucose time to peak ↓ Time interval to pre-prandial glucose value | |
| 3 | Buhling et al. (15) Germany | GDM vs. NDP: ↑ Time to peak ↑ Hyperglycemia | |
| 4 | Yogev et al. (16) USA | GDM vs. NDP: ↑ Hypoglycemia events | |
| 5 | Buhling et al. (17) Germany | GDM vs. NDP: Postprandial glucose time to peak: Nil Postprandial glucose values: Nil | |
| 6 | Cypryk et al. (12) Poland | GDM vs. NDP: Glycemic variability: Nil | |
| 7 | McLachlan et al. (18)Australia | ↑ Hyperglycemia | |
| 8 | Seshiah et al. (20) India | GDM vs. NDP: ↑ Postprandial glucose levels | |
| 9 | Dalfra et al. (3) Italy | GDM w/insulin vs. GDM w/dietary restriction: ↑ Glycemic variability | |
| 10 | Mazze et al. (21) USA | GDM vs. NDP: ↑ Glycemic variability | |
| 11 | Colatrella et al. (22) Italy | GDM vs. NDP: ↑ Postprandial time to peak ↑ Postprandial levels | |
| 12 | Dalfra et al. (23) Italy | GDM vs. NDP: ↑ Glycemic variability | |
| 13 | Su et al. (24) China | GDM vs. NDP: ↑ Glycemic variability | |
| 14 | Kusunoki et al. (27) Japan | Postprandial glucose levels and HbA1c: Positive correlation | |
| 15 | Wang et al. (28) China | pGDM vs. w/out pGDM: ↑ Glycemic variability | |
| 16 | Alfadhli et al. (29) Saudi Arabia | CGM vs. SMBG Glycemic variability improved | |
| 17 | Carreiro et al. (30) Brazil | GDM vs. NDP: ↑ Variability ↑ Postprandial levels | |
| 18 | Naik et al. (32) India | GDM vs. NDP: ↑ Postprandial levels | |
| 19 | Panyakat et al. (33) Thailand | CGM: Glycemic variability and pregnancy outcomes associations: nil | |
| 20 | Pustozerov et al. (35)Russia | GDM vs. NDP: ↑ Postprandial levels ↑ Fasting glucose |
Major findings of articles focused on dysglycemia and glycemic profiling.
CGM, Continuous glucose monitoring; SMBG, Self-monitoring of blood glucose; GDM, Gestational diabetes; NDP, Non-diabetic pregnancy; T1D, type 1 diabetes.
GDM vs. NDP in Terms of CGM-Derived Glycemic Profiling (Table 4)
Average Daily Glucose Levels
As expected, all three studies focusing on glucose profiling found that women with GDM had higher average glucose levels and that CGM was better than SMBG in detecting subtle glucose changes. Yogev et al. enrolled 117 patients (82 GDM vs. 35 NDP) and identified more asymptomatic hypoglycemic episodes (i.e., no dizziness or sweating due to hypoglycemia) by using CGM in the GDM group compared to the controls (25 vs. 0, P < 0.001) (16). Buhling et al. found similar results when they enrolled 8 non-pregnant healthy women and 56 pregnant women (17 diet-treated GDM, 15 impaired glucose tolerance (IGT) and 24 NDP) (15). The duration of hyperglycemia above 6.7 mmol/L [120 mg/dL] was higher in those with GDM or IGT than NDP (190 vs. 381.8 vs. 138 min; P < 0.05) (15). Colatrella et al. focused on glucose profiles during breastfeeding in two different groups: 18 women with GDM during pregnancy that resolved postpartum and 15 non-diabetic healthy pregnant controls (22). Glycemic levels were significantly higher in those who had GDM than NDP [5.6 mmol/L (101.4 mg/dL) vs. 4.9 mmol/L (87.5 mg/dL), P = 0.002] (22).
Postprandial Glucose Peak Level, Time to Peak, and Time to Resume to Baseline
The majority of research (4 out of 5, 80%) showed that patients with GDM had higher postprandial glucose levels. Naik et al. enrolled 30 women (20 GDM vs. 10 NDP) and found 1 h postprandial glucose levels were higher in women with GDM than NDP [7.21 mmol/L (130 mg/dL) vs. 5.98 mmol/L (108 mg/dL) P = 0.01] (32). Pustozerov et al. recruited 62 patients (49 GDM vs. 13 NDP) and demonstrated higher postprandial peak levels in patients with GDM than NDP [6.6 mmol/L (119 mg/dL) vs. 6.5 mmol/L (117 mg/dL), P = 0.02] (35). Carreiro et al. enrolled 50 patients (36 with GDM, 14 BMI-matched NDP) and found that at both breakfast and dinner times, postprandial glucose levels were consistently higher in the GDM group compared to NDP in both 1- and 2-h time points (i.e., 1 h after breakfast: 6.5 mmol/L [118 mg/dL] vs. 5.5 mmol/L [100 mg/dL]; 1 h after dinner: 6 mmol/L [109 mg/dL] vs. 5.2 mmol/L [94 mg/dL]; 2 h after breakfast: 5.8 mmol/L [105 mg/dL] vs. 4.9 mmol/L [89 mg/dL], 2 h after dinner: 5.8 mmol/L [105 mg/dL] vs. 5.2 mmol/L [93 mg/dL], P < 0.05 for all) (30). Finally, Seshiah et al. enrolled 24 women (12 GDM vs. 12 NDP) and found higher glucose levels 1 h post-meal in women with GDM than NDP, either using CGM [6.8 mmol/L (122.22 mg/dL) vs. 5.7 mmol/L (102.68 mg/dL), P < 0.05] or SMBG [7.2 mmol/L (129.9 mg/dL) vs. 6.5 mmol/L (117.5 mg/dL), P < 0.05] (20).
In terms of postprandial time to peak, there was no consensus among researchers. Buhling et al. conducted two studies focused on postprandial time to peak. Initially, they found that patients with GDM had longer time to peak compared to patients with NDP (54 vs. 47 min, P = 0.008) (15). Subsequently, they enrolled 49 women (13 GDM vs. 36 NDP) but found no significant differences in postprandial time to peak between NDP and diabetic groups (74 vs. 82 min, P > 0.05) (17). Carreiro et al. found similar results to Buhling's first study in that postprandial time to peak was longer in the GDM group than NDP group (56–70 min vs. 33 min, P < 0.02) at breakfast time (30).
For postprandial time to resume, only one study by Ben-Haroush et al. enrolled 45 women with GDM and found that women with diet-treated GDM took a longer time to return to pre-prandial glucose levels than those with insulin-treated GDM (134 vs. 111 min, P = 0.022) (14).
Glycemic Variability
Glycemic variability was consistently found to be increased in patients with GDM compared to NDP. Mazze et al. enrolled 76 patients (51 NDP, 25 GDM) and found significantly higher glucose variability in the GDM group compared to NDP [Interquartile range (IQR): 1.94 mmol/L (35 mg/dL) vs. 1.3 mmol/L (23 mg/dL), P < 0.0001] (21). Su et al. enrolled 70 women (30 GDM, 20 NDP, 20 non-pregnant healthy controls) and found similar results: mean amplitude of glucose excursions (MAGE) values were higher in the GDM group compared to both NDP and non-pregnant healthy controls [3.5 mmol/L (63 mg/dL) vs. 2.3 mmol/L (41 mg/dL) vs. 1.7 mmol/L (30.6 mg/dL); P < 0.01] (24). Other parameters of glycemic variability with significant differences between GDM and NDP included mean of daily differences (MODD) [1.6 mmol/L (29 mg/dL) vs. 1.2 mmol/L (21.6 mg/dL) vs. 1.0 mmol/L (18 mg/dL) P < 0.05], standard deviation of blood glucose (SDBG) [1.5 mmol/L (27 mg/dL) vs. 1.0 mmol/L (18 mg/dL) vs. 0.9 mmol/L (16 mg/dL), P < 0.01], and mean of continuous 24 h blood glucose (MBG) [8.6 mmol/L (155 mg/dL) vs. 6.2 mmol/L (112 mg/dL) vs. 4.8 mmol/L (86 mg/dL), P < 0.01] (24). There were two studies conducted by Dalfra et al. One focused on treatment differences in patients with GDM (insulin vs. diet), and they found patients on insulin had significantly higher glycemic variability compared to those on dietary restriction [MAGE: 3.5 mmol/L (63.3 mg/dL) vs. 2.1 mmol/L (38 mg/dL); P = 0.012] (3). The other study compared 30 patients (20 GDM vs. 10 NDP) and found that GDM had significant correlations between indicators of glycemic variability (MAGE and IQR r = 0.84, P < 0.001; MAGE and continuous overlapping net glycemic action (CONGA) r = 0.54, P = 0.03) (23). Only one study by Alfadhli et al. compared glucose differences between day 1 and day 4 use of CGM device among GDM mothers (29). They found significant reduction of glucose levels after a 4-day's use of CGM [MBG: 1.0 mmol/L (18 mg/dL), P = 0.016; SDBG: 0.25 mmol/L (4.5 mg/dL), P = 0.034] (29).
Interestingly, there was one study which compared mothers of NDP with and without history of GDM. Wang et al. recruited 96 women (48 NDP with prior GDM and 48 without) and found that those with prior GDM had higher MBG [6.5 mmol/L (117 mg/dL) vs. 5.9 mmol/L (106 mg/dL), P = 0.004], SDBG [1.3 mmol/L (23 mg/dL) vs. 0.9 mmol/L (16 mg/dL), P < 0.001], MODD [1.4 mmol/L (25 mg/dL) vs. 1.1 mmol/L (19.8 mg/dL), P = 0.002], MAGE [2.7 mmol/L (48.6 mg/dL) vs. 1.8 mmol/L (32.4 mg/dL), P < 0.001], and AUC [26.8 mmol/L (483 mg/dL) vs. 19.2 mmol/L (346 mg/dL) per hour, P < 0.001] compared to NDP without prior GDM (28).
However, one study did report contrasting results relating to glycemic variability from the findings above. Cypryk et al. enrolled 19 pregnant women (12 GDM, 7 NDP) and found no significant differences between groups for mean 24 h glycaemia, mean glucose level during the night, and duration of glycaemia below 3.3 mmol/L [60 mg/dL] or above 6.7 mmol/L [120 mg/dL], regardless of whether CGM or SMBG was used to measure the parameters (12).
CGM Use in Clinical/Intervention Utility (Table 5)
CGM in Altering Treatment Effect
All four studies focused on using CGM to make medication adjustments in patients with GDM found that CGM led to more treatment changes. Yogev et al. recruited 2 GDM patients and CGM was worn twice (once at baseline and once at 4 weeks after treatment) (39). After adjusting for their insulin regimens, there was a significant decrease in the total time of undetected hyperglycemia (152 vs. 89 min/day, P < 0.03) and in the 24-h mean glucose levels [6.5 mmol/L (117 mg/dL) vs. 5.6 mmol/L (101 mg/dL), P < 0.02] at post-treatment evaluation (39). Kestila et al. found similar results in their study of 73 patients with GDM (36 CGM, 37 SMBG) (19). Those in the CGM group had more patients treated with anti-hyperglycemic medication (31 vs. 8%, P = 0.01) (19). Wei et al. compared CGM use (n = 58) to SMBG use (n = 62) in 120 women with GDM and found that insulin was more commonly used in the CGM group (31.3 vs. 12.7%, P = 0.02), although there was no significant difference in the required dose (31). Yu et al. also found that more women in the CGM group received insulin vs. SMBG [41 out of 150 (27.3%) vs. 23 out of 190 (12.1%), P < 0.001] (26).
Table 5
| Clinical/Intervention utility | |||
|---|---|---|---|
| References, Country | Treatment effect | Maternal GWG | |
| 1 | Yogev et al. (12) UK | ↑ Medical monitoring and treatment adjustment | |
| 2 | Kestila et al. (19) Finland | ↑ Medical monitoring and treatment adjustment | |
| 3 | Hernandez et al. (25) USA | ↑Complex-carbohydrate and ↓ fat diet maintained glycaemia below guidelines | |
| 4 | Wei et al. (31) China | ↑ Medical Monitoring and treatment adjustment | CGM vs. SMBG: ↓ |
| 5 | Panyakat et al. (33) Thailand | GWG and BW correlated |
Major findings of articles with focus on clinical and intervention utility.
GWG, Gestational weight gain; CGM, Continuous glucose monitoring; SMBG, Self-monitoring of blood glucose; BW, Birth weight.
One trial conducted by Paramasivam et al. studied CGM vs. SMBG use in preventing HbA1c increases in 50 women with insulin-treated GDM (34). They found that HbA1c had a smaller increase in the CGM group (P = 0.024) and that mean HbA1c was lower in the CGM group at 37 weeks (P < 0.006) (34). The vast majority of patients in the CGM group also achieved an HbA1c <39 mmol/mol (5.8%) at 37 weeks (92 vs. 68%, P = 0.012) (34).
CGM Effect on Gestational Weight Gain (GWG)
Only one RCT studied GWG and found that CGM use lowered the amount of GWG compared to SMBG. Wei et al. recruited 120 women with GDM and randomized them to CGM (n = 58) or SMBG (n = 62), and found a significant difference in GWG (13.56 kg vs. 14.75 kg, P = 0.004) (31). A prospective observational study by Panyakat et al. did find a significant correlation between GWG and BW percentiles using CGM (r = 0.437, P = 0.002) (33).
Other Implications of CGM Use
Postprandial Glucose and HbA1c Levels (Table 4)
Kusunoki et al. enrolled 22 patients with GDM and used CGM to find that postprandial glucose levels were positively correlated with HbA1c levels (r = 0.5, P = 0.03) and patients' BMI (r = 0.55, P = 0.01) (27).
Hyperglycemia and Birth Weight (Table 3)
Sung et al. recruited 53 healthy pregnant women and followed them with gestational diabetes screening (38). They found that the magnitude and duration of hyperglycemia (≥110 mg/dl) had a consistent positive correlation with BW (Area under the curve (AUC) 6.1–7.8 mmol/L [110–140 mg/dl]: all r = 0.29, all P < 0.05) (38).
Diet and Average Glycaemia (Table 5)
Hernandez et al. used CGM to monitor changes in glycaemia in a crossover study using two different diets: a conventional lower carbohydrate and higher fat diet vs. a higher-complex carbohydrate and lower fat diet (25). They found that although the higher-complex diet led to higher levels of average glucose levels, overall the diet still maintained glycaemia below the recommended guidelines (25).
Pregnancy Outcomes (Table 4)
A different study by Panyakat et al. which enrolled 55 women with GDM and investigated the associations between third trimester glucose variability parameters and pregnancy outcomes using CGM (33). They found no associations between the two in terms of LGA, BW, cesarean section rate, and neonatal complications (33).
Discussion
In this systematic review with 29 online published original articles, CGM use has better user acceptability and feedback regarding satisfaction than SMBG use in daily glucose monitoring. Furthermore, most studies showed that CGM use in pregnant women with GDM was more effective in detecting hypoglycemia, hyperglycemia and increased glycemic variability than SMBG use in both GDM subjects and non-GDM subjects. As for treatment effect, CGM use led to more frequent use of insulin, better glycemic control, and reduced GWG in patients with GDM. However, most studies showed inconclusive results regarding CGM use in order to improve maternal and fetal outcomes.
Current research shows that CGM is able to provide more comprehensive glucose data and is convenient for the patient (40). Its clinical utility has been well demonstrated in patients with T1D and T2D by reducing risks of dysglycemia and improving their quality of life (41). However, several questions remain unanswered with regards to CGM use in patients with GDM: (1) Whether CGM can detect early glycemic variability for GDM diagnosis; (2) Whether CGM can subsequently moderate treatment strategies of GDM; (3) Whether CGM can eventually improve maternal and fetal outcomes. Due to these gaps in knowledge, CGM has yet to be adopted widely for use in pregnancies complicated by GDM.
In our review, there are consistent findings on the effect of CGM use on detection of dysglycemia (13, 18), higher glycemic variability (3, 21, 23, 24, 28, 29), higher postprandial glucose peaks in women with GDM (20, 30, 32, 35), and improved treatment effect (19, 25, 31, 34, 39). CGM use contributed positively to treatment effect as clinicians were more aware of patients' hyperglycemic and hypoglycemic episodes, so as to moderate the strategies of their medication (i.e., insulin) by altering dosage and frequency. In general, these findings suggest better clinical utility of CGM use in patients with GDM, compared with traditional SMBG use.
One major gap in clinical knowledge—whether CGM use improves maternal and fetal outcomes—has not been filled with plausible or convincing results. Past findings are still equivocal, as described above (26, 29, 31, 37). The null findings might be due to the lack of study power to detect pregnancy outcomes which are not highly prevalent in relatively small samples (42). Therefore, future studies with larger samples size, longer follow-up, and consistent study design are warranted to detect the practical effect of CGM on maternal and fetal outcomes.
There are a few other aspects of CGM which are worth exploring in future research, such as pregnant users' acceptability and effect on GWG and glycemic control. In our review, only two studies surveyed user acceptability and accuracy of CGM (18, 36), while several studies have been done in patients with T2D with high compliance rates (>90%) (43). Therefore, more should be done on pregnant women, especially on those with GDM, in order to implement universal application of CGM during pregnancy. Future research that tackles the current challenges and difficulties of CGM use in women with or without hyperglycemia during pregnancy could be beneficial for CGM user compliance and glucose control. In addition, one study in our review reported a beneficial effect of CGM on reducing GWG (31). It is worth further investigating whether such self-regulatory effect of CGM use (i.e., reduced GWG and lower glycemic levels during pregnancy) has an impact on improving pregnancy and fetal outcomes.
The strength of this literature review was the novelty of summarizing the clinical utility and treatment effects of CGM use on pregnancies complicated by GDM only, via a set of stringent selection criteria across three reputable medical databases. However, this review is not without limitations. First, there was a possibility of selection bias as we only included articles written in English with full text available and published in the past 2 decades. Second, when filtering articles by title, we might have excluded relevant articles that did not have the keywords (i.e., CGM, pregnancy, GDM) in their title.
In summary, there is sufficient evidence showing that CGM is effective at capturing gestational glucose profiles and improving treatment effect among pregnant women with GDM. The use of CGM provides good user acceptability, detects more dysglycemia than SMBG use, and detects higher glycemic variability in GDM pregnancies than normal pregnancies. Since CGM use is somewhat effective at improving GDM pregnancy outcomes, further research with larger sample sizes, better compliance, and longer monitoring times to detect these effects are warranted.
Statements
Data availability statement
All datasets for this study are included in the manuscript and the supplementary files.
Author contributions
QY drafted the manuscript and conducted the literature search. IA edited the manuscript and partially conceived the research idea. KT edited the manuscript and provided funding for this research. L-JL verified the literature search, conceived the research idea, and edited the manuscript.
Conflict of interest
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
- GDM
Gestational diabetes
- SMBG
Self-monitoring of blood glucose
- CGM
Continuous glucose monitoring
- RCTs
Randomized controlled trials
- BW
Birth weight
- GA
Gestational age
- GWG
Gestational weight gain
- NDP
Non-diabetic pregnancies
- IADPSG
Internal Association of Diabetes and Pregnancy Groups
- HAPO
Hyperglycemia and adverse pregnancy outcome
- WHO
World Health Organization
- NICE
National Institute for Clinical Evidence
- T1D
Type 1 Diabetes
- T2D
Type 2 Diabetes
- GDS
GlucoDay S
- NICU
Neonatal intensive care unit
- IGT
Impaired glucose tolerance
- PCOS
Polycystic ovarian syndrome
- BMI
Body Mass Index
- IQR
Interquartile range
- MAGE
Mean amplitude of glucose excursions
- MODD
Mean of daily differences
- SDBG
Standard deviation of blood glucose
- MBG
Mean of continuous 24 h blood glucose.
Abbreviations
References
1.
WHO. Diagnostic criteria and classification of hyperglycaemia first detected in pregnancy: a World Health Organization Guideline. Diabetes Res Clin Pract. (2014) 3:341–63. 10.1016/j.diabres.2013.10.012
2.
CoustanDRLoweLPMetzgerBEDyerAR. The Hyperglycemia and Adverse Pregnancy Outcome (HAPO) study: paving the way for new diagnostic criteria for gestational diabetes mellitus. Am J Obstet Gynecol. (2010) 202:654.e1–6. 10.1016/j.ajog.2010.04.006
3.
Dalfrà MGSartoreGDi CianniGMelloGLencioniCOttanelliSet al. Glucose variability in diabetic pregnancy. Diabetes Technol Ther. (2011) 13:853–9. 10.1089/dia.2010.0145
4.
ZhuYZhangC. Prevalence of gestational diabetes and risk of progression to type 2 diabetes: a global perspective. Curr Diab Rep. (2016) 16:7. 10.1007/s11892-015-0699-x
5.
Excellence N.I.f.H.a.C. Type 2 Diabetes: Prevention in People at High Risk (2012).
6.
ChitayatLZisserHJovanovicL. Continuous glucose monitoring during pregnancy. Diabetes Technol Ther. (2009) 11(Suppl 1):S105–11. 10.1089/dia.2008.0136
7.
CossonEBazBGaryFPharisienINguyenMTSandre-BanonDet al. Poor reliability and poor adherence to self-monitoring of blood glucose are common in women with gestational diabetes mellitus and may be associated with poor pregnancy outcomes. Diabetes Care. (2017) 40:1181–6. 10.2337/dc17-0369
8.
O'KaneMJPickupJ. Self-monitoring of blood glucose in diabetes: is it worth it?Ann Clin Biochem. (2009) 46(Pt 4):273–82. 10.1258/acb.2009.009011
9.
VoormolenDNDeVriesJHEversIMMolBWFranxA. The efficacy and effectiveness of continuous glucose monitoring during pregnancy: a systematic review. Obstet Gynecol Surv. (2013) 68:753–63. 10.1097/OGX.0000000000000002
10.
SlatteryDChoudharyP. Clinical use of continuous glucose monitoring in adults with type 1 diabetes. Diabetes Technol Ther. (2017) 19:S55–S61. 10.1089/dia.2017.0051
11.
CarlsonALMullenDMBergenstalRM. Clinical use of continuous glucose monitoring in adults with type 2 diabetes. Diabetes Technol Ther. (2017) 19:S4–11. 10.1089/dia.2017.0024
12.
CyprykKBartyzelLZurawska-KlisMMlynarskiWSzadkowskaAWilczynskiJet al. Continuous glucose monitoring in type 1 diabetes pregnancy shows that fetal heart rate correlates with maternal glycemia. Diabetes Technol Ther. (2015) 17:619–24. 10.1089/dia.2014.0255
13.
ChenRYogevYBen-HaroushAJovanovicLHodMPhillipM. Continuous glucose monitoring for the evaluation and improved control of gestational diabetes mellitus. J Matern Fetal Neonatal Med. (2003) 14:256–60. 10.1080/713606657
14.
Ben-HaroushAYogevYChenRRosennBHodMLangerO. The postprandial glucose profile in the diabetic pregnancy. Am J Obstet Gynecol. (2004) 191:576–81. 10.1016/j.ajog.2004.01.055
15.
BühlingKJKurzidimBWolfCWohlfarthKMahmoudiMWäscherCet al. Introductory experience with the continuous glucose monitoring system (CGMS; Medtronic Minimed) in detecting hyperglycemia by comparing the self-monitoring of blood glucose (SMBG) in non-pregnant women and in pregnant women with impaired glucose tolerance and gestational diabetes. Exp Clin Endocrinol Diabetes. (2004) 112:556–60. 10.1055/s-2004-830399
16.
YogevYBen-HaroushAChenRRosennBHodMLangerO. Undiagnosed asymptomatic hypoglycemia: diet, insulin, and glyburide for gestational diabetic pregnancy. Obstet Gynecol. (2004) 104:88–93. 10.1097/01.AOG.0000129239.82126.a1
17.
BühlingKJWinkelTWolfCKurzidimBMahmoudiMWohlfarthKet al. Optimal timing for postprandial glucose measurement in pregnant women with diabetes and a non-diabetic pregnant population evaluated by the Continuous Glucose Monitoring System (CGMS). J Perinat Med. (2005) 33:125–31. 10.1515/JPM.2005.024
18.
McLachlanKJenkinsAO'NealD. The role of continuous glucose monitoring in clinical decision-making in diabetes in pregnancy. Aust N Z J Obstet Gynaecol. (2007) 47:186–90. 10.1111/j.1479-828X.2007.00716.x
19.
KestiläKKEkbladUURönnemaaT. Continuous glucose monitoring versus self-monitoring of blood glucose in the treatment of gestational diabetes mellitus. Diabetes Res Clin Pract. (2007) 77:174–9. 10.1016/j.diabres.2006.12.012
20.
SeshiahVChandrasekarABalajiVBalajiMSSrinivasanASuganthiSet al. Glycemic excursions in Indian pregnant women monitored by continuous glucose monitoring system—A pilot study. Diabetes Metabolic Syndrome. (2008) 2:179–84. 10.1016/j.dsx.2008.05.002
21.
MazzeRYogevYLangerO. Measuring glucose exposure and variability using continuous glucose monitoring in normal and abnormal glucose metabolism in pregnancy. J Matern Fetal Neonatal Med. (2012) 25:1171–5. 10.3109/14767058.2012.670413
22.
ColatrellaAFramarinoMToscanoVBongiovanniMFestaCMatteiLet al. Continuous glucose monitoring during breastfeeding in women with recent gestational diabetes mellitus. Diabetes Technol Ther. (2012) 14:576–82. 10.1089/dia.2011.0266
23.
Dalfrà MGChilelliNCDi CianniGMelloGLencioniCBiagioniSet al. Glucose fluctuations during gestation: an additional tool for monitoring pregnancy complicated by diabetes. Int J Endocrinol. (2013) 2013:279021. 10.1155/2013/279021
24.
SuJBWangXQChenJFWuGJinYXuFet al. Glycemic variability in gestational diabetes mellitus and its association with β cell function. Endocrine. (2013) 43:370–5. 10.1007/s12020-012-9753-5
25.
HernandezTLVan PeltREAndersonMADanielsLJWestNADonahooWTet al. A higher-complex carbohydrate diet in gestational diabetes mellitus achieves glucose targets and lowers postprandial lipids: a randomized crossover study. Diabetes Care. (2014) 37:1254–62. 10.2337/dc13-2411
26.
YuFLvLLiangZWangYWenJLinXet al. Continuous glucose monitoring effects on maternal glycemic control and pregnancy outcomes in patients with gestational diabetes mellitus: a prospective cohort study. J Clin Endocrinol Metab. (2014) 99:4674–82. 10.1210/jc.2013-4332
27.
KusunokiYKatsunoTNakaeRWatanabeKOchiFTokudaMet al. Insulin resistance and β-cell function influence postprandial blood glucose levels in Japanese patients with gestational diabetes mellitus. Gynecol Endocrinol. (2015) 31:929–33. 10.3109/09513590.2015.1075498
28.
WangYMZhaoLHSuJBQiaoHFWangXHXuFet al. Glycemic variability in normal glucose tolerance women with the previous gestational diabetes mellitus. Diabetol Metab Syndr. (2015) 7:82. 10.1186/s13098-015-0077-5
29.
AlfadhliEOsmanEBasriT. Use of a real time continuous glucose monitoring system as an educational tool for patients with gestational diabetes. Diabetol Metab Syndr. (2016) 8:48. 10.1186/s13098-016-0161-5
30.
CarreiroMPLauriaMWNavesGNMirandaPALeiteRBRajãoKMet al. Seventy two-hour glucose monitoring profiles in mild gestational diabetes mellitus: differences from healthy pregnancies and influence of diet counseling. Eur J Endocrinol. (2016) 175:201–9. 10.1530/EJE-16-0015
31.
WeiQSunZYangYYuHDingHWangS. Effect of a CGMS and SMBG on maternal and neonatal outcomes in gestational diabetes mellitus: a randomized controlled trial. Sci Rep. (2016) 6:19920. 10.1038/srep19920
32.
NaikDHesarghatta ShyamasunderADoddabelavangala MruthyunjayaMGupta PatilRPaulTVChristinaFet al. Masked hypoglycemia in pregnancy. J Diabetes. (2017) 9:778–86. 10.1111/1753-0407.12485
33.
PanyakatWSPhatihattakornCSriwijitkamolASunsaneevithayakulPPhaophanAPhichitkankaA. Correlation between third trimester glycemic variability in non-insulin-dependent gestational diabetes mellitus and adverse pregnancy and fetal outcomes. J Diabetes Sci Technol. (2018) 12:622–9. 10.1177/1932296817752374
34.
ParamasivamSSChinnaKSinghAKKRatnasingamJIbrahimLLimLLet al. Continuous glucose monitoring results in lower HbA1c in Malaysian women with insulin-treated gestational diabetes: a randomized controlled trial. Diabet Med. (2018) 35:1118–29. 10.1111/dme.13649
35.
PustozerovEPopovaPTkachukABolotkoYYuldashevZGrinevaE. Development and evaluation of a mobile personalized blood glucose prediction system for patients with gestational diabetes mellitus. JMIR Mhealth Uhealth. (2018) 6:e6. 10.2196/mhealth.9236
36.
ScottEMBilousRWKautzky-WillerA. Accuracy, user acceptability, and safety evaluation for the freestyle libre flash glucose monitoring system when used by pregnant women with diabetes. Diabetes Technol Ther. (2018) 20:180–8. 10.1089/dia.2017.0386
37.
VoormolenDNDeVriesJHSansonRMEHeringaMPde ValkHWKokMet al. Continuous glucose monitoring during diabetic pregnancy (GlucoMOMS): a multicentre randomized controlled trial. Diabetes Obes Metab. (2018) 20:1894–902. 10.1111/dom.13310
38.
SungJFKogutEALeeHCMannanJLNavabiKTaslimiMMet al. Correlation of continuous glucose monitoring profiles with pregnancy outcomes in nondiabetic women. Am J Perinatol. (2015) 32:461–8. 10.1055/s-0034-1390344
39.
YogevYChenRKaplanBPhillipMHodM. Continuous glucose monitoring for treatment adjustment in diabetic pregnancies—a pilot study. Diabetic Med. (2003) 20:558–62. 10.1046/j.1464-5491.2003.00959.x
40.
AjjanRACummingsMHJenningsPLeelarathnaLRaymanGWilmotEG. Accuracy of flash glucose monitoring and continuous glucose monitoring technologies: Implications for clinical practice. Diab Vasc Dis Res. (2018) 15:175–84. 10.1177/1479164118756240
41.
RodbardD. Continuous glucose monitoring: a review of recent studies demonstrating improved glycemic outcomes. Diabetes Technol Therapeut. (2017) 19:S25–37. 10.1089/dia.2017.0035
42.
NajafianMCheraghiM. Occurrence of fetal macrosomia rate and its maternal and neonatal complications: a 5-year cohort study. ISRN Obstetr Gynecol. (2012) 2012:353791. 10.5402/2012/353791
43.
TaylorPJThompsonCHBrinkworthGD. Effectiveness and acceptability of continuous glucose monitoring for type 2 diabetes management: a narrative review. J Diabetes Invest. (2018) 9:713–25. 10.1111/jdi.12807
Summary
Keywords
gestational diabetes, continuous glucose monitoring, self-monitoring of blood glucose, literature review, maternal and fetal outcomes
Citation
Yu Q, Aris IM, Tan KH and Li L-J (2019) Application and Utility of Continuous Glucose Monitoring in Pregnancy: A Systematic Review. Front. Endocrinol. 10:697. doi: 10.3389/fendo.2019.00697
Received
08 April 2019
Accepted
26 September 2019
Published
11 October 2019
Volume
10 - 2019
Edited by
Margarita de Veciana, Eastern Virginia Medical School, United States
Reviewed by
Joseph Aloi, Wake Forest Baptist Medical Center, United States; Nirav Dhanesha, The University of Iowa, United States
Updates
Copyright
© 2019 Yu, Aris, Tan and Li.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Ling-Jun Li queenie.li.l@kkh.com.sg
This article was submitted to Clinical Diabetes, a section of the journal Frontiers in Endocrinology
Disclaimer
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.