  • 4 Department of Mechanical Science and Bioengineering, Osaka University, Japan

PhysioDesigner is Integrated Development Environment for physiome biological modeling based on modeling description language PHML[1]. It can handle ODE, DDE, SDE and PDE. Here we will show how EEG (electroencephalogram) analysis can be done under this environment. EEG analysis PHML model is shown in Fig. 1. EEG model is composed of three parts, morphology module, Maxwell equation module and current source capsule module. Current source capsule module is composed of current strength module and frequency module. Morphology module gives cubic simulation region information in which brain structure is stored. Current source module gives information of rhythmic current source which is an origin of EEG signal. Maxwell equation module solves Maxwell equation which needs conductivity values extracted from brain image and gives EEG signal. Brain conductivity is extracted from CT image of grey, white, csf and skull images. For the purpose, image processing tool "Imageviewer" has been developed. Imageviewer has four functions, image, extract, smoothing and resolution. Conductivity matrix file is generated from Imageviewer and is used for Maxwell equation to get electric potentials.

To solve partial differential equation, finite element method is used because of its adaptability to complex structure and high numerical accuracy. We adopt a script based solver FreeFem++[2]. Conductivity file is read from FreeFem++ and its values are assigned to each cubic point. Current source is a dipole whose current strength rhythmically vibrates at a decided frequency. Current strength q and angular frequency ω obey following two equations. In this case, αwave of 10Hz is assumed. EEG PHML model has two kinds of equations, Maxwell PDE and current source ODE. Each transient equation runs at different time step. In PhysioDesigner, FreeFem++ parser reads multi time step information and assigns it to each equation to run it at different time step. EEG signal is observed at standard configuration electrodes. In this case, 64 channel electrodes is adopted and MNI standard coordinates conversion is done automatically. This configuration is stored in one segment of cuboid. [1] http://physiodesigner.org [2] http://www.frefem.org

Figure 1

Keywords: computational neuroscience, EEG analyzis, Partial Differential Equations, PHM, imaging

Conference: 5th INCF Congress of Neuroinformatics, Munich, Germany, 10 Sep - 12 Sep, 2012.

Presentation Type: Poster

Topic: Neuroinformatics

Citation: Oka H, Iwasaki K, Asai Y, Nomura T and Yamaguchi Y (2014). EEG Analysis in PhysioDesigner. Front. Neuroinform. Conference Abstract: 5th INCF Congress of Neuroinformatics. doi: 10.3389/conf.fninf.2014.08.00006

Copyright: The abstracts in this collection have not been subject to any Frontiers peer review or checks, and are not endorsed by Frontiers. They are made available through the Frontiers publishing platform as a service to conference organizers and presenters.

The copyright in the individual abstracts is owned by the author of each abstract or his/her employer unless otherwise stated.

Each abstract, as well as the collection of abstracts, are published under a Creative Commons CC-BY 4.0 (attribution) licence (https://creativecommons.org/licenses/by/4.0/) and may thus be reproduced, translated, adapted and be the subject of derivative works provided the authors and Frontiers are attributed.

For Frontiers’ terms and conditions please see https://www.frontiersin.org/legal/terms-and-conditions.

Received: 21 Mar 2013; Published Online: 27 Feb 2014.

* Correspondence: Dr. Hideki Oka, NIJC, RIKEN BSI, Wako, Japan, yokoy@brain.riken.jp